Parameters
The BYD Atto 3 has 174 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery cell 1 BYD_12V_BAT_CELL_1
- Service 22
DID 000D - Module
762 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2022 to 2026.
12V battery MOS temperature BYD_12V_BAT_MOS_T
- Service 22
DID 0014 - Module
762 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
12V battery negative contact temperature BYD_12V_BAT_NEGATIVE_T
- Service 22
DID 0013 - Module
762 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
12V battery voltage BYD_12V_BAT_V
- Service 22
DID 000C - Module
762 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2022 to 2026.
Accumulated charge energy BYD_ACCUMULATED_CHG_ENERGY
- Service 22
DID 0011 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 kWh
- Unit
- kWh
In testing for 2022 to 2026.
Accumulated charge power, ah BYD_ACCUMULATED_CHG
- Service 22
DID 000F - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 16777215 Ah
- Unit
- Ah
In testing for 2022 to 2026.
Accumulated discharge energy BYD_ACCUMULATED_DCHG_ENERGY
- Service 22
DID 0012 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 kWh
- Unit
- kWh
In testing for 2022 to 2026.
Accumulated discharge power, ah BYD_ACCUMULATED_DCHG
- Service 22
DID 0010 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 16777215 Ah
- Unit
- Ah
In testing for 2022 to 2026.
Battery pack average temperature BYD_BAT_PACK_AVG_T
- Service 22
DID 0032 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Battery total current BYD_BAT_TOT_CURRENT
- Service 22
DID 0009 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- -500 to 6053 A
- Unit
- A
In testing for 2022 to 2026.
Battery total voltage BYD_BAT_TOT_V
- Service 22
DID 0008 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2022 to 2026.
Charge times BYD_CHG_TIMES
- Service 22
DID 000B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2026.
High voltage battery pack factory capacity BYD_HVBAT_PACK_FACTORY
- Service 22
DID 1FFC - Module
7E7 → 7EF - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655 Ah
- Unit
- Ah
In testing for 2022 to 2026.
High voltage battery pack factory capacity BYD_HVBAT_PACK_FACTORY_CAP
- Service 22
DID 1FFE - Module
7E7 → 7EF - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655 Ah
- Unit
- Ah
In testing for 2022 to 2026.
High voltage battery pack factory state of charge BYD_HVBAT_PACK_FACTORY_ST_CHG
- Service 22
DID 1FFE - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2022 to 2026.
High voltage battery pack nominal state of charge BYD_HVBAT_PACK_NOMINAL
- Service 22
DID 1FFC - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2022 to 2026.
High voltage battery state of charge BYD_HVBAT_ST_CHG
- Service 22
DID 0005 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2022 to 2026.
Highest voltage cell # BYD_HIGHEST_V_CELL
- Service 22
DID 002C - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Highest voltage cell value BYD_HIGHEST_V_CELL_7E7
- Service 22
DID 002D - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Lowest voltage cell # BYD_LOWEST_V_CELL
- Service 22
DID 002A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Lowest voltage cell value BYD_LOWEST_V_CELL_7E7
- Service 22
DID 002B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Maximum allowed charge power BYD_MAX_ALLOWED_CHG
- Service 22
DID 000A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553 kW
- Unit
- kW
In testing for 2022 to 2026.
Maximum allowed discharge power BYD_MAX_ALLOWED_DCHG
- Service 22
DID 000E - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553 kW
- Unit
- kW
In testing for 2022 to 2026.
Pack 1 highest voltage cell number BYD_PACK_1_HIGHEST_V
- Service 22
DID 0162 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 1 highest voltage cell value BYD_PACK_1_HIGHEST_V_CELL
- Service 22
DID 0163 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 1 lowest voltage cell number BYD_PACK_1_LOWEST_V_CELL
- Service 22
DID 0160 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 1 lowest voltage cell value BYD_PACK_1_LOWEST_V_CELL_7E7
- Service 22
DID 0161 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 2 highest voltage cell number BYD_PACK_2_HIGHEST_V
- Service 22
DID 0166 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 2 highest voltage cell value BYD_PACK_2_HIGHEST_V_CELL
- Service 22
DID 0167 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 2 lowest voltage cell number BYD_PACK_2_LOWEST_V_CELL
- Service 22
DID 0164 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 2 lowest voltage cell value BYD_PACK_2_LOWEST_V_CELL_7E7
- Service 22
DID 0165 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 3 highest voltage cell number BYD_PACK_3_HIGHEST_V
- Service 22
DID 016A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 3 highest voltage cell value BYD_PACK_3_HIGHEST_V_CELL
- Service 22
DID 016B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 3 lowest voltage cell number BYD_PACK_3_LOWEST_V_CELL
- Service 22
DID 0168 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 3 lowest voltage cell value BYD_PACK_3_LOWEST_V_CELL_7E7
- Service 22
DID 0169 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 4 highest voltage cell number BYD_PACK_4_HIGHEST_V
- Service 22
DID 016E - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 4 highest voltage cell value BYD_PACK_4_HIGHEST_V_CELL
- Service 22
DID 016F - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 4 lowest voltage cell number BYD_PACK_4_LOWEST_V_CELL
- Service 22
DID 016C - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 4 lowest voltage cell value BYD_PACK_4_LOWEST_V_CELL_7E7
- Service 22
DID 016D - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 5 highest voltage cell number BYD_PACK_5_HIGHEST_V
- Service 22
DID 0172 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 5 highest voltage cell value BYD_PACK_5_HIGHEST_V_CELL
- Service 22
DID 0173 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 5 lowest voltage cell number BYD_PACK_5_LOWEST_V_CELL
- Service 22
DID 0170 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 5 lowest voltage cell value BYD_PACK_5_LOWEST_V_CELL_7E7
- Service 22
DID 0171 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 6 highest voltage cell number BYD_PACK_6_HIGHEST_V
- Service 22
DID 0176 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 6 highest voltage cell value BYD_PACK_6_HIGHEST_V_CELL
- Service 22
DID 0177 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 6 lowest voltage cell number BYD_PACK_6_LOWEST_V_CELL
- Service 22
DID 0174 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 6 lowest voltage cell value BYD_PACK_6_LOWEST_V_CELL_7E7
- Service 22
DID 0175 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 7 highest voltage cell number BYD_6_PACK_7_HIGHEST_V
- Service 22
DID 017A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 highest voltage cell number BYD_PACK_7_HIGHEST_V
- Service 22
DID 019E - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 highest voltage cell value BYD_6_PACK_7_HIGHEST_V_CELL
- Service 22
DID 017B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 7 highest voltage cell value BYD_PACK_7_HIGHEST_V_CELL
- Service 22
DID 019F - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 7 lowest voltage cell number BYD_6_PACK_7_LOWEST_V_CELL
- Service 22
DID 0178 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 lowest voltage cell number BYD_PACK_7_LOWEST_V_CELL
- Service 22
DID 019C - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 lowest voltage cell value BYD_PACK_7_LOWEST_V_CELL_781
- Service 22
DID 019D - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 7 lowest voltage cell value BYD_PACK_7_LOWEST_V_CELL_7E7
- Service 22
DID 0179 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 8 highest voltage cell number BYD_6_PACK_8_HIGHEST_V
- Service 22
DID 017E - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 highest voltage cell number BYD_PACK_8_HIGHEST_V
- Service 22
DID 01A6 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 highest voltage cell value BYD_6_PACK_8_HIGHEST_V_CELL
- Service 22
DID 017F - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 8 highest voltage cell value BYD_PACK_8_HIGHEST_V_CELL
- Service 22
DID 01A7 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 8 lowest voltage cell number BYD_6_PACK_8_LOWEST_V_CELL
- Service 22
DID 017C - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 lowest voltage cell number BYD_PACK_8_LOWEST_V_CELL
- Service 22
DID 01A4 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 lowest voltage cell value BYD_PACK_8_LOWEST_V_CELL_781
- Service 22
DID 01A5 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 8 lowest voltage cell value BYD_PACK_8_LOWEST_V_CELL_7E7
- Service 22
DID 017D - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 9 highest voltage cell number BYD_6_PACK_9_HIGHEST_V
- Service 22
DID 0182 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 highest voltage cell number BYD_PACK_9_HIGHEST_V
- Service 22
DID 01AE - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 highest voltage cell value BYD_6_PACK_9_HIGHEST_V_CELL
- Service 22
DID 0183 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 9 highest voltage cell value BYD_PACK_9_HIGHEST_V_CELL
- Service 22
DID 01AF - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 9 lowest voltage cell number BYD_6_PACK_9_LOWEST_V_CELL
- Service 22
DID 0180 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 lowest voltage cell number BYD_PACK_9_LOWEST_V_CELL
- Service 22
DID 01AC - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 lowest voltage cell value BYD_PACK_9_LOWEST_V_CELL_781
- Service 22
DID 01AD - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 9 lowest voltage cell value BYD_PACK_9_LOWEST_V_CELL_7E7
- Service 22
DID 0181 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 10 highest voltage cell number BYD_6_PACK_10_HIGHEST_V
- Service 22
DID 0186 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 highest voltage cell number BYD_PACK_10_HIGHEST_V
- Service 22
DID 01B6 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 highest voltage cell value BYD_6_PACK_10_HIGHEST_V_CELL
- Service 22
DID 0187 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 10 highest voltage cell value BYD_PACK_10_HIGHEST_V_CELL
- Service 22
DID 01B7 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 10 lowest voltage cell number BYD_6_PACK_10_LOWEST_V
- Service 22
DID 0184 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 lowest voltage cell number BYD_PACK_10_LOWEST_V
- Service 22
DID 01B4 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 lowest voltage cell value BYD_6_PACK_10_LOWEST_V_CELL
- Service 22
DID 0185 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 10 lowest voltage cell value BYD_PACK_10_LOWEST_V_CELL
- Service 22
DID 01B5 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 11 highest voltage cell number BYD_PACK_11_HIGHEST_V
- Service 22
DID 018A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 highest voltage cell number BYD_PACK_11_HIGHEST_V_CELL_NUMBER
- Service 22
DID 01BE - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 highest voltage cell value BYD_PACK_11_HIGHEST_V_CELL
- Service 22
DID 018B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 11 highest voltage cell value BYD_PACK_11_HIGHEST_V_CELL_781
- Service 22
DID 01BF - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 11 lowest voltage cell number BYD_PACK_11_LOWEST_V
- Service 22
DID 0188 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 lowest voltage cell number BYD_PACK_11_LOWEST_V_CELL_NUMBER
- Service 22
DID 01BC - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 lowest voltage cell value BYD_PACK_11_LOWEST_V_CELL
- Service 22
DID 0189 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 11 lowest voltage cell value BYD_PACK_11_LOWEST_V_CELL_781
- Service 22
DID 01BD - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 12 highest voltage cell number BYD_PACK_12_HIGHEST_V
- Service 22
DID 018E - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 highest voltage cell number BYD_PACK_12_HIGHEST_V_CELL_NUMBER
- Service 22
DID 01C6 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 highest voltage cell value BYD_PACK_12_HIGHEST_V_CELL
- Service 22
DID 018F - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 12 highest voltage cell value BYD_PACK_12_HIGHEST_V_CELL_781
- Service 22
DID 01C7 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 12 lowest voltage cell number BYD_PACK_12_LOWEST_V
- Service 22
DID 018C - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 lowest voltage cell number BYD_PACK_12_LOWEST_V_CELL_NUMBER
- Service 22
DID 01C4 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 lowest voltage cell value BYD_PACK_12_LOWEST_V_CELL
- Service 22
DID 018D - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 12 lowest voltage cell value BYD_PACK_12_LOWEST_V_CELL_781
- Service 22
DID 01C5 - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 13 highest voltage cell number BYD_PACK_13_HIGHEST_V
- Service 22
DID 0192 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 highest voltage cell number BYD_PACK_13_HIGHEST_V_CELL_NUMBER
- Service 22
DID 01CE - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 highest voltage cell value BYD_PACK_13_HIGHEST_V_CELL
- Service 22
DID 0193 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 13 highest voltage cell value BYD_PACK_13_HIGHEST_V_CELL_781
- Service 22
DID 01CF - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 13 lowest voltage cell number BYD_PACK_13_LOWEST_V
- Service 22
DID 0190 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 lowest voltage cell number BYD_PACK_13_LOWEST_V_CELL_NUMBER
- Service 22
DID 01CC - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 lowest voltage cell value BYD_PACK_13_LOWEST_V_CELL
- Service 22
DID 0191 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 13 lowest voltage cell value BYD_PACK_13_LOWEST_V_CELL_781
- Service 22
DID 01CD - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 14 highest voltage cell number BYD_PACK_14_HIGHEST_V
- Service 22
DID 0196 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 14 highest voltage cell value BYD_PACK_14_HIGHEST_V_CELL
- Service 22
DID 0197 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 14 lowest voltage cell number BYD_PACK_14_LOWEST_V
- Service 22
DID 0194 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 14 lowest voltage cell value BYD_PACK_14_LOWEST_V_CELL
- Service 22
DID 0195 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 15 highest voltage cell number BYD_PACK_15_HIGHEST_V
- Service 22
DID 019A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 15 highest voltage cell value BYD_PACK_15_HIGHEST_V_CELL
- Service 22
DID 019B - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
Pack 15 lowest voltage cell number BYD_PACK_15_LOWEST_V
- Service 22
DID 0198 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 15 lowest voltage cell value BYD_PACK_15_LOWEST_V_CELL
- Service 22
DID 0199 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2022 to 2026.
State of charge, actual BYD_ST_CHG_ACT
- Service 22
DID 1FFD - Module
781 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2022 to 2026.
Control
Brake depth BYD_BRAKE_DEPTH
- Service 22
DID 0102 - Module
743 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2022 to 2026.
Engine
AC side current BYD_AC_SIDE_CURRENT
- Service 22
DID 0007 - Module
797 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 2022 to 2026.
Boost pressure, actual BYD_BOOST_P_ACT
- Service 22
DID 010F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Boost pressure, target BYD_BOOST_P_TGT
- Service 22
DID 0112 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Boost temperature BYD_BOOST_T
- Service 22
DID 2129 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2022 to 2026.
Cooling fan duty cycle BYD_COOLING_FAN_DUTY
- Service 22
DID 0019 - Module
797 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2022 to 2026.
Cylinder head oil temperature, modeled BYD_CYL_HEAD_OIL_T
- Service 22
DID 0107 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to -273 °C
- Unit
- °C
In testing for 2022 to 2026.
Engine coolant temperature BYD_ECT
- Service 22
DID 001F - Module
743 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Engine outlet water temperature BYD_ENG_OUTLET_WATER_T
- Service 22
DID 0103 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2022 to 2026.
Engine total mileage BYD_ENG_TOT_MILEAGE
- Service 22
DID 210A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2022 to 2026.
Engine water temperature at start BYD_ENG_WATER_T_START
- Service 22
DID 017C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2022 to 2026.
Front drive, target torque BYD_FRONT_DRIVE_TGT_TQ
- Service 22
DID 0104 - Module
743 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3776 to 2776 N·m
- Unit
- N·m
In testing for 2022 to 2026.
Highest temperature cell # BYD_HIGHEST_T_CELL
- Service 22
DID 0030 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Highest temperature cell value BYD_HIGHEST_T_CELL_7E7
- Service 22
DID 0031 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Instrument panel total mileage BYD_INSTRUMENT_PANEL_TOT
- Service 22
DID 2143 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2022 to 2026.
Lowest temperature cell # BYD_LOWEST_T_CELL
- Service 22
DID 002E - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Lowest temperature cell value BYD_LOWEST_T_CELL_7E7
- Service 22
DID 002F - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Misfires, cylinder 1 BYD_MIS_1
- Service 22
DID 0180 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Misfires, cylinder 2 BYD_MIS_2
- Service 22
DID 0183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Misfires, cylinder 3 BYD_MIS_3
- Service 22
DID 0182 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Misfires, cylinder 4 BYD_MIS_4
- Service 22
DID 0181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2022 to 2026.
Pack 7 highest temperature cell number BYD_PACK_7_HIGHEST_T
- Service 22
DID 01A2 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 highest temperature cell value BYD_PACK_7_HIGHEST_T_CELL
- Service 22
DID 01A3 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 7 lowest temperature cell number BYD_PACK_7_LOWEST_T_CELL
- Service 22
DID 01A0 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 7 lowest temperature cell value BYD_PACK_7_LOWEST_T_CELL_781
- Service 22
DID 01A1 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 8 highest temperature cell number BYD_PACK_8_HIGHEST_T
- Service 22
DID 01AA - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 highest temperature cell value BYD_PACK_8_HIGHEST_T_CELL
- Service 22
DID 01AB - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 8 lowest temperature cell number BYD_PACK_8_LOWEST_T_CELL
- Service 22
DID 01A8 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 8 lowest temperature cell value BYD_PACK_8_LOWEST_T_CELL_781
- Service 22
DID 01A9 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 9 highest temperature cell number BYD_PACK_9_HIGHEST_T
- Service 22
DID 01B2 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 highest temperature cell value BYD_PACK_9_HIGHEST_T_CELL
- Service 22
DID 01B3 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 9 lowest temperature cell number BYD_PACK_9_LOWEST_T_CELL
- Service 22
DID 01B0 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 9 lowest temperature cell value BYD_PACK_9_LOWEST_T_CELL_781
- Service 22
DID 01B1 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 10 highest temperature cell number BYD_PACK_10_HIGHEST_T
- Service 22
DID 01BA - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 highest temperature cell value BYD_PACK_10_HIGHEST_T_CELL
- Service 22
DID 01BB - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 10 lowest temperature cell number BYD_PACK_10_LOWEST_T
- Service 22
DID 01B8 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 10 lowest temperature cell value BYD_PACK_10_LOWEST_T_CELL
- Service 22
DID 01B9 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 11 highest temperature cell number BYD_PACK_11_HIGHEST_T
- Service 22
DID 01C2 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 highest temperature cell value BYD_PACK_11_HIGHEST_T_CELL
- Service 22
DID 01C3 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 11 lowest temperature cell number BYD_PACK_11_LOWEST_T
- Service 22
DID 01C0 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 11 lowest temperature cell value BYD_PACK_11_LOWEST_T_CELL
- Service 22
DID 01C1 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 12 highest temperature cell number BYD_PACK_12_HIGHEST_T
- Service 22
DID 01CA - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 highest temperature cell value BYD_PACK_12_HIGHEST_T_CELL
- Service 22
DID 01CB - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 12 lowest temperature cell number BYD_PACK_12_LOWEST_T
- Service 22
DID 01C8 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 12 lowest temperature cell value BYD_PACK_12_LOWEST_T_CELL
- Service 22
DID 01C9 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 13 highest temperature cell number BYD_PACK_13_HIGHEST_T
- Service 22
DID 01D2 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 highest temperature cell value BYD_PACK_13_HIGHEST_T_CELL
- Service 22
DID 01D3 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Pack 13 lowest temperature cell number BYD_PACK_13_LOWEST_T
- Service 22
DID 01D0 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2022 to 2026.
Pack 13 lowest temperature cell value BYD_PACK_13_LOWEST_T_CELL
- Service 22
DID 01D1 - Module
781 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Radiator outlet water temperature BYD_RADIATOR_OUTLET_T
- Service 22
DID 211F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2022 to 2026.
Rear drive, target torque BYD_REAR_DRIVE_TGT_TQ
- Service 22
DID 0105 - Module
743 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3776 to 2776 N·m
- Unit
- N·m
In testing for 2022 to 2026.
Throttle depth BYD_THROTTLE_DEPTH
- Service 22
DID 0101 - Module
743 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2022 to 2026.
Times off full power, second-rate BYD_TIMES_OFF_FULL_POWER
- Service 22
DID 0004 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2026.
Fuel
Fuel flow BYD_FUEL_FLOW
- Service 22
DID 0111 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.039
- Unit
- Raw value
In testing for 2022 to 2026.
Fuel level input BYD_FLI_INPUT
- Service 22
DID 0106 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 L
- Unit
- L
In testing for 2022 to 2026.
Movement
Vehicle speed BYD_VSS
- Service 22
DID 0025 - Module
743 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2022 to 2026.
Tires
Front left wheel speed BYD_FL_WHL_SPD
- Service 22
DID 2001 - Module
782 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4503 km/h
- Unit
- km/h
In testing for 2022 to 2026.
Front right wheel speed BYD_FR_WHL_SPD
- Service 22
DID 2001 - Module
782 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 4503 km/h
- Unit
- km/h
In testing for 2022 to 2026.
Rear left wheel speed BYD_RL_WHL_SPD
- Service 22
DID 2001 - Module
782 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 4503 km/h
- Unit
- km/h
In testing for 2022 to 2026.
Rear right wheel speed BYD_RR_WHL_SPD
- Service 22
DID 2001 - Module
782 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4503 km/h
- Unit
- km/h
In testing for 2022 to 2026.
Steering wheel angle BYD_STEER_WHL_ANG
- Service 22
DID 0003 - Module
783 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2022 to 2026.
Trips
Odometer BYD_ODO
- Service 22
DID 0026 - Module
743 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1677721 km
- Unit
- km
In testing for 2022 to 2026.