BYD Sealion 6

Parameters

The BYD Sealion 6 has 174 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery cell 1 SEALION_12V_BAT_CELL_1

  • Service 22DID 000D
  • Module762
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2027.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery cell 1 SEALION_12V_BAT_CELL_1

  • Service 22DID 000D
  • Module762
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2027.

12V battery MOS temperature SEALION_12V_BAT_MOS_T

  • Service 22DID 0014
  • Module762
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

12V battery negative contact temperature SEALION_12V_BAT_NEGATIVE_T

  • Service 22DID 0013
  • Module762
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

12V battery voltage SEALION_12V_BAT_V

  • Service 22DID 000C
  • Module762
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2027.

Accumulated charge energy SEALION_ACCUMULATED_CHG_ENERGY

  • Service 22DID 0011
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 kWh
Unit
kWh

In testing for 2020 to 2027.

Accumulated charge power, ah SEALION_ACCUMULATED_CHG

  • Service 22DID 000F
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 Ah
Unit
Ah

In testing for 2020 to 2027.

Accumulated discharge energy SEALION_ACCUMULATED_DCHG_ENERGY

  • Service 22DID 0012
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 kWh
Unit
kWh

In testing for 2020 to 2027.

Accumulated discharge power, ah SEALION_ACCUMULATED_DCHG

  • Service 22DID 0010
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 Ah
Unit
Ah

In testing for 2020 to 2027.

Battery pack average temperature SEALION_BAT_PACK_AVG_T

  • Service 22DID 0032
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Battery total current SEALION_BAT_TOT_CURRENT

  • Service 22DID 0009
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10−500
Range
-500 to 6053 A
Unit
A

In testing for 2020 to 2027.

Battery total voltage SEALION_BAT_TOT_V

  • Service 22DID 0008
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2020 to 2027.

Charge times SEALION_CHG_TIMES

  • Service 22DID 000B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2027.

High voltage battery pack factory capacity SEALION_HVBAT_PACK_FACTORY

  • Service 22DID 1FFC
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655 Ah
Unit
Ah

In testing for 2020 to 2027.

High voltage battery pack factory capacity SEALION_HVBAT_PACK_FACTORY_CAP

  • Service 22DID 1FFE
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655 Ah
Unit
Ah

In testing for 2020 to 2027.

High voltage battery pack factory state of charge SEALION_HVBAT_PACK_FACTORY_ST_CHG

  • Service 22DID 1FFE
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2020 to 2027.

High voltage battery pack nominal state of charge SEALION_HVBAT_PACK_NOMINAL

  • Service 22DID 1FFC
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2020 to 2027.

High voltage battery state of charge SEALION_HVBAT_ST_CHG

  • Service 22DID 0005
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2027.

Highest voltage cell # SEALION_HIGHEST_V_CELL

  • Service 22DID 002C
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Highest voltage cell value SEALION_HIGHEST_V_CELL_7E7

  • Service 22DID 002D
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Lowest voltage cell # SEALION_LOWEST_V_CELL

  • Service 22DID 002A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Lowest voltage cell value SEALION_LOWEST_V_CELL_7E7

  • Service 22DID 002B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Maximum allowed charge power SEALION_MAX_ALLOWED_CHG

  • Service 22DID 000A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kW
Unit
kW

In testing for 2020 to 2027.

Maximum allowed discharge power SEALION_MAX_ALLOWED_DCHG

  • Service 22DID 000E
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kW
Unit
kW

In testing for 2020 to 2027.

Pack 1 highest voltage cell number SEALION_PACK_1_HIGHEST_V

  • Service 22DID 0162
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 1 highest voltage cell value SEALION_PACK_1_HIGHEST_V_CELL

  • Service 22DID 0163
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 1 lowest voltage cell number SEALION_PACK_1_LOWEST_V_CELL

  • Service 22DID 0160
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 1 lowest voltage cell value SEALION_PACK_1_LOWEST_V_CELL_7E7

  • Service 22DID 0161
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 2 highest voltage cell number SEALION_PACK_2_HIGHEST_V

  • Service 22DID 0166
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 2 highest voltage cell value SEALION_PACK_2_HIGHEST_V_CELL

  • Service 22DID 0167
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 2 lowest voltage cell number SEALION_PACK_2_LOWEST_V_CELL

  • Service 22DID 0164
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 2 lowest voltage cell value SEALION_PACK_2_LOWEST_V_CELL_7E7

  • Service 22DID 0165
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 3 highest voltage cell number SEALION_PACK_3_HIGHEST_V

  • Service 22DID 016A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 3 highest voltage cell value SEALION_PACK_3_HIGHEST_V_CELL

  • Service 22DID 016B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 3 lowest voltage cell number SEALION_PACK_3_LOWEST_V_CELL

  • Service 22DID 0168
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 3 lowest voltage cell value SEALION_PACK_3_LOWEST_V_CELL_7E7

  • Service 22DID 0169
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 4 highest voltage cell number SEALION_PACK_4_HIGHEST_V

  • Service 22DID 016E
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 4 highest voltage cell value SEALION_PACK_4_HIGHEST_V_CELL

  • Service 22DID 016F
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 4 lowest voltage cell number SEALION_PACK_4_LOWEST_V_CELL

  • Service 22DID 016C
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 4 lowest voltage cell value SEALION_PACK_4_LOWEST_V_CELL_7E7

  • Service 22DID 016D
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 5 highest voltage cell number SEALION_PACK_5_HIGHEST_V

  • Service 22DID 0172
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 5 highest voltage cell value SEALION_PACK_5_HIGHEST_V_CELL

  • Service 22DID 0173
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 5 lowest voltage cell number SEALION_PACK_5_LOWEST_V_CELL

  • Service 22DID 0170
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 5 lowest voltage cell value SEALION_PACK_5_LOWEST_V_CELL_7E7

  • Service 22DID 0171
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 6 highest voltage cell number SEALION_PACK_6_HIGHEST_V

  • Service 22DID 0176
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 6 highest voltage cell value SEALION_PACK_6_HIGHEST_V_CELL

  • Service 22DID 0177
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 6 lowest voltage cell number SEALION_PACK_6_LOWEST_V_CELL

  • Service 22DID 0174
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 6 lowest voltage cell value SEALION_PACK_6_LOWEST_V_CELL_7E7

  • Service 22DID 0175
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 7 highest voltage cell number SEALION_6_PACK_7_HIGHEST_V

  • Service 22DID 017A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 highest voltage cell number SEALION_PACK_7_HIGHEST_V

  • Service 22DID 019E
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 highest voltage cell value SEALION_6_PACK_7_HIGHEST_V_CELL

  • Service 22DID 017B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 7 highest voltage cell value SEALION_PACK_7_HIGHEST_V_CELL

  • Service 22DID 019F
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 7 lowest voltage cell number SEALION_6_PACK_7_LOWEST_V_CELL

  • Service 22DID 0178
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 lowest voltage cell number SEALION_PACK_7_LOWEST_V_CELL

  • Service 22DID 019C
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 lowest voltage cell value SEALION_PACK_7_LOWEST_V_CELL_781

  • Service 22DID 019D
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 7 lowest voltage cell value SEALION_PACK_7_LOWEST_V_CELL_7E7

  • Service 22DID 0179
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 8 highest voltage cell number SEALION_6_PACK_8_HIGHEST_V

  • Service 22DID 017E
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 highest voltage cell number SEALION_PACK_8_HIGHEST_V

  • Service 22DID 01A6
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 highest voltage cell value SEALION_6_PACK_8_HIGHEST_V_CELL

  • Service 22DID 017F
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 8 highest voltage cell value SEALION_PACK_8_HIGHEST_V_CELL

  • Service 22DID 01A7
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 8 lowest voltage cell number SEALION_6_PACK_8_LOWEST_V_CELL

  • Service 22DID 017C
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 lowest voltage cell number SEALION_PACK_8_LOWEST_V_CELL

  • Service 22DID 01A4
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 lowest voltage cell value SEALION_PACK_8_LOWEST_V_CELL_781

  • Service 22DID 01A5
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 8 lowest voltage cell value SEALION_PACK_8_LOWEST_V_CELL_7E7

  • Service 22DID 017D
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 9 highest voltage cell number SEALION_6_PACK_9_HIGHEST_V

  • Service 22DID 0182
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 highest voltage cell number SEALION_PACK_9_HIGHEST_V

  • Service 22DID 01AE
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 highest voltage cell value SEALION_6_PACK_9_HIGHEST_V_CELL

  • Service 22DID 0183
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 9 highest voltage cell value SEALION_PACK_9_HIGHEST_V_CELL

  • Service 22DID 01AF
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 9 lowest voltage cell number SEALION_6_PACK_9_LOWEST_V_CELL

  • Service 22DID 0180
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 lowest voltage cell number SEALION_PACK_9_LOWEST_V_CELL

  • Service 22DID 01AC
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 lowest voltage cell value SEALION_PACK_9_LOWEST_V_CELL_781

  • Service 22DID 01AD
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 9 lowest voltage cell value SEALION_PACK_9_LOWEST_V_CELL_7E7

  • Service 22DID 0181
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 10 highest voltage cell number SEALION_6_PACK_10_HIGHEST_V

  • Service 22DID 0186
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 highest voltage cell number SEALION_PACK_10_HIGHEST_V

  • Service 22DID 01B6
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 highest voltage cell value SEALION_6_PACK_10_HIGHEST_V_CELL

  • Service 22DID 0187
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 10 highest voltage cell value SEALION_PACK_10_HIGHEST_V_CELL

  • Service 22DID 01B7
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 10 lowest voltage cell number SEALION_6_PACK_10_LOWEST_V

  • Service 22DID 0184
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 lowest voltage cell number SEALION_PACK_10_LOWEST_V

  • Service 22DID 01B4
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 lowest voltage cell value SEALION_6_PACK_10_LOWEST_V_CELL

  • Service 22DID 0185
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 10 lowest voltage cell value SEALION_PACK_10_LOWEST_V_CELL

  • Service 22DID 01B5
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 11 highest voltage cell number SEALION_PACK_11_HIGHEST_V

  • Service 22DID 018A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 highest voltage cell number SEALION_PACK_11_HIGHEST_V_CELL_NUMBER

  • Service 22DID 01BE
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 highest voltage cell value SEALION_PACK_11_HIGHEST_V_CELL

  • Service 22DID 018B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 11 highest voltage cell value SEALION_PACK_11_HIGHEST_V_CELL_781

  • Service 22DID 01BF
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 11 lowest voltage cell number SEALION_PACK_11_LOWEST_V

  • Service 22DID 0188
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 lowest voltage cell number SEALION_PACK_11_LOWEST_V_CELL_NUMBER

  • Service 22DID 01BC
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 lowest voltage cell value SEALION_PACK_11_LOWEST_V_CELL

  • Service 22DID 0189
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 11 lowest voltage cell value SEALION_PACK_11_LOWEST_V_CELL_781

  • Service 22DID 01BD
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 12 highest voltage cell number SEALION_PACK_12_HIGHEST_V

  • Service 22DID 018E
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 highest voltage cell number SEALION_PACK_12_HIGHEST_V_CELL_NUMBER

  • Service 22DID 01C6
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 highest voltage cell value SEALION_PACK_12_HIGHEST_V_CELL

  • Service 22DID 018F
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 12 highest voltage cell value SEALION_PACK_12_HIGHEST_V_CELL_781

  • Service 22DID 01C7
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 12 lowest voltage cell number SEALION_PACK_12_LOWEST_V

  • Service 22DID 018C
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 lowest voltage cell number SEALION_PACK_12_LOWEST_V_CELL_NUMBER

  • Service 22DID 01C4
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 lowest voltage cell value SEALION_PACK_12_LOWEST_V_CELL

  • Service 22DID 018D
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 12 lowest voltage cell value SEALION_PACK_12_LOWEST_V_CELL_781

  • Service 22DID 01C5
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 13 highest voltage cell number SEALION_PACK_13_HIGHEST_V

  • Service 22DID 0192
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 highest voltage cell number SEALION_PACK_13_HIGHEST_V_CELL_NUMBER

  • Service 22DID 01CE
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 highest voltage cell value SEALION_PACK_13_HIGHEST_V_CELL

  • Service 22DID 0193
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 13 highest voltage cell value SEALION_PACK_13_HIGHEST_V_CELL_781

  • Service 22DID 01CF
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 13 lowest voltage cell number SEALION_PACK_13_LOWEST_V

  • Service 22DID 0190
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 lowest voltage cell number SEALION_PACK_13_LOWEST_V_CELL_NUMBER

  • Service 22DID 01CC
  • Module781
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 lowest voltage cell value SEALION_PACK_13_LOWEST_V_CELL

  • Service 22DID 0191
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 13 lowest voltage cell value SEALION_PACK_13_LOWEST_V_CELL_781

  • Service 22DID 01CD
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 14 highest voltage cell number SEALION_PACK_14_HIGHEST_V

  • Service 22DID 0196
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 14 highest voltage cell value SEALION_PACK_14_HIGHEST_V_CELL

  • Service 22DID 0197
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 14 lowest voltage cell number SEALION_PACK_14_LOWEST_V

  • Service 22DID 0194
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 14 lowest voltage cell value SEALION_PACK_14_LOWEST_V_CELL

  • Service 22DID 0195
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 15 highest voltage cell number SEALION_PACK_15_HIGHEST_V

  • Service 22DID 019A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 15 highest voltage cell value SEALION_PACK_15_HIGHEST_V_CELL

  • Service 22DID 019B
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

Pack 15 lowest voltage cell number SEALION_PACK_15_LOWEST_V

  • Service 22DID 0198
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 15 lowest voltage cell value SEALION_PACK_15_LOWEST_V_CELL

  • Service 22DID 0199
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2027.

State of charge, actual SEALION_ST_CHG_ACT

  • Service 22DID 1FFD
  • Module781
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2020 to 2027.

Control

Brake depth SEALION_BRAKE_DEPTH

  • Service 22DID 0102
  • Module743
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2027.

Engine

AC side current SEALION_AC_SIDE_CURRENT

  • Service 22DID 0007
  • Module797
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2020 to 2027.

Boost pressure, actual SEALION_BOOST_P_ACT

  • Service 22DID 010F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Boost pressure, target SEALION_BOOST_P_TGT

  • Service 22DID 0112
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Boost temperature SEALION_BOOST_T

  • Service 22DID 2129
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2027.

Cooling fan duty cycle SEALION_COOLING_FAN_DUTY

  • Service 22DID 0019
  • Module797
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2027.

Cylinder head oil temperature, modeled SEALION_CYL_HEAD_OIL_T

  • Service 22DID 0107
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31280000−273.15
Range
-273 to -273 °C
Unit
°C

In testing for 2020 to 2027.

Engine coolant temperature SEALION_ECT

  • Service 22DID 001F
  • Module743
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Engine outlet water temperature SEALION_ENG_OUTLET_WATER_T

  • Service 22DID 0103
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2027.

Engine total mileage SEALION_ENG_TOT_MILEAGE

  • Service 22DID 210A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2020 to 2027.

Engine water temperature at start SEALION_ENG_WATER_T_START

  • Service 22DID 017C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2027.

Front drive, target torque SEALION_FRONT_DRIVE_TGT_TQ

  • Service 22DID 0104
  • Module743
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10−500
Range
-3776 to 2776 N·m
Unit
N·m

In testing for 2020 to 2027.

Highest temperature cell # SEALION_HIGHEST_T_CELL

  • Service 22DID 0030
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Highest temperature cell value SEALION_HIGHEST_T_CELL_7E7

  • Service 22DID 0031
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Instrument panel total mileage SEALION_INSTRUMENT_PANEL_TOT

  • Service 22DID 2143
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2020 to 2027.

Lowest temperature cell # SEALION_LOWEST_T_CELL

  • Service 22DID 002E
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Lowest temperature cell value SEALION_LOWEST_T_CELL_7E7

  • Service 22DID 002F
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Misfires, cylinder 1 SEALION_MIS_1

  • Service 22DID 0180
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Misfires, cylinder 2 SEALION_MIS_2

  • Service 22DID 0183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Misfires, cylinder 3 SEALION_MIS_3

  • Service 22DID 0182
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Misfires, cylinder 4 SEALION_MIS_4

  • Service 22DID 0181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2020 to 2027.

Pack 7 highest temperature cell number SEALION_PACK_7_HIGHEST_T

  • Service 22DID 01A2
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 highest temperature cell value SEALION_PACK_7_HIGHEST_T_CELL

  • Service 22DID 01A3
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 7 lowest temperature cell number SEALION_PACK_7_LOWEST_T_CELL

  • Service 22DID 01A0
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 7 lowest temperature cell value SEALION_PACK_7_LOWEST_T_CELL_781

  • Service 22DID 01A1
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 8 highest temperature cell number SEALION_PACK_8_HIGHEST_T

  • Service 22DID 01AA
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 highest temperature cell value SEALION_PACK_8_HIGHEST_T_CELL

  • Service 22DID 01AB
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 8 lowest temperature cell number SEALION_PACK_8_LOWEST_T_CELL

  • Service 22DID 01A8
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 8 lowest temperature cell value SEALION_PACK_8_LOWEST_T_CELL_781

  • Service 22DID 01A9
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 9 highest temperature cell number SEALION_PACK_9_HIGHEST_T

  • Service 22DID 01B2
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 highest temperature cell value SEALION_PACK_9_HIGHEST_T_CELL

  • Service 22DID 01B3
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 9 lowest temperature cell number SEALION_PACK_9_LOWEST_T_CELL

  • Service 22DID 01B0
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 9 lowest temperature cell value SEALION_PACK_9_LOWEST_T_CELL_781

  • Service 22DID 01B1
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 10 highest temperature cell number SEALION_PACK_10_HIGHEST_T

  • Service 22DID 01BA
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 highest temperature cell value SEALION_PACK_10_HIGHEST_T_CELL

  • Service 22DID 01BB
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 10 lowest temperature cell number SEALION_PACK_10_LOWEST_T

  • Service 22DID 01B8
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 10 lowest temperature cell value SEALION_PACK_10_LOWEST_T_CELL

  • Service 22DID 01B9
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 11 highest temperature cell number SEALION_PACK_11_HIGHEST_T

  • Service 22DID 01C2
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 highest temperature cell value SEALION_PACK_11_HIGHEST_T_CELL

  • Service 22DID 01C3
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 11 lowest temperature cell number SEALION_PACK_11_LOWEST_T

  • Service 22DID 01C0
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 11 lowest temperature cell value SEALION_PACK_11_LOWEST_T_CELL

  • Service 22DID 01C1
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 12 highest temperature cell number SEALION_PACK_12_HIGHEST_T

  • Service 22DID 01CA
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 highest temperature cell value SEALION_PACK_12_HIGHEST_T_CELL

  • Service 22DID 01CB
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 12 lowest temperature cell number SEALION_PACK_12_LOWEST_T

  • Service 22DID 01C8
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 12 lowest temperature cell value SEALION_PACK_12_LOWEST_T_CELL

  • Service 22DID 01C9
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 13 highest temperature cell number SEALION_PACK_13_HIGHEST_T

  • Service 22DID 01D2
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 highest temperature cell value SEALION_PACK_13_HIGHEST_T_CELL

  • Service 22DID 01D3
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Pack 13 lowest temperature cell number SEALION_PACK_13_LOWEST_T

  • Service 22DID 01D0
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2020 to 2027.

Pack 13 lowest temperature cell value SEALION_PACK_13_LOWEST_T_CELL

  • Service 22DID 01D1
  • Module781
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2027.

Radiator outlet water temperature SEALION_RADIATOR_OUTLET_T

  • Service 22DID 211F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2027.

Rear drive, target torque SEALION_REAR_DRIVE_TGT_TQ

  • Service 22DID 0105
  • Module743
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10−500
Range
-3776 to 2776 N·m
Unit
N·m

In testing for 2020 to 2027.

Throttle depth SEALION_THROTTLE_DEPTH

  • Service 22DID 0101
  • Module743
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2027.

Times off full power, second-rate SEALION_TIMES_OFF_FULL_POWER

  • Service 22DID 0004
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2027.

Fuel

Fuel flow SEALION_FUEL_FLOW

  • Service 22DID 0111
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×149250000000
Range
0 to 0.039
Unit
Raw value

In testing for 2020 to 2027.

Fuel level input SEALION_FLI_INPUT

  • Service 22DID 0106
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2020 to 2027.

Movement

Vehicle speed SEALION_VSS

  • Service 22DID 0025
  • Module743
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2020 to 2027.

Tires

Front left wheel speed SEALION_FL_WHL_SPD

  • Service 22DID 2001
  • Module782
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×274940000
Range
0 to 4503 km/h
Unit
km/h

In testing for 2020 to 2027.

Front right wheel speed SEALION_FR_WHL_SPD

  • Service 22DID 2001
  • Module782
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×274940000
Range
0 to 4503 km/h
Unit
km/h

In testing for 2020 to 2027.

Rear left wheel speed SEALION_RL_WHL_SPD

  • Service 22DID 2001
  • Module782
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×274940000
Range
0 to 4503 km/h
Unit
km/h

In testing for 2020 to 2027.

Rear right wheel speed SEALION_RR_WHL_SPD

  • Service 22DID 2001
  • Module782
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×274940000
Range
0 to 4503 km/h
Unit
km/h

In testing for 2020 to 2027.

Steering wheel angle SEALION_STEER_WHL_ANG

  • Service 22DID 0003
  • Module783
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2020 to 2027.

Trips

Odometer SEALION_ODO

  • Service 22DID 0026
  • Module743
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2027.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.