Parameters
The Daihatsu Hijet has 306 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
+BM voltage HIJET_BM_V
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2014 to 2026.
Battery current HIJET_BAT_CURRENT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2014 to 2026.
Battery temperature HIJET_BAT_T
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2014 to 2026.
Battery voltage HIJET_BAT_V
- Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2014 to 2026.
Battery voltage HIJET_BATTERY_VOLTAGE_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2014 to 2026.
Charge contactor current HIJET_SCC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Main connector solenoid current HIJET_SMC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Main relay a, solenoid current HIJET_SLA_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Main relay r solenoid current HIJET_SLR_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Output speed sensor voltage HIJET_NOUT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2014 to 2026.
Regenerative braking cooperation HIJET_REGEN_COOPERATION
- Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Regenerative operation HIJET_FR_REGEN_OPERATION
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2014 to 2026.
Regenerative request HIJET_FR_REGEN_REQUEST
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2014 to 2026.
Relay control solenoid current HIJET_SRC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Service contactor solenoid current HIJET_SSC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2014 to 2026.
Turbine speed sensor voltage HIJET_NT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2014 to 2026.
Climate
Communication with air conditioner HIJET_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Communication with HV HIJET_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Communication with valvematic HIJET_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Control
A/C compressor HIJET_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Accelerator sensor voltage, 1 HIJET_ACCEL_SENS_1_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Accelerator sensor voltage, 2 HIJET_ACCEL_SENS_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Anti-lock brake warning light HIJET_ABS_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Brake warning light HIJET_BRAKE_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Buzzer HIJET_BUZZER
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Communication with brake HIJET_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Cruise control live brake cancel HIJET_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Electrical load signal 1 HIJET_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Electrical load signal 2 HIJET_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Electronically controlled brake warning light HIJET_ECB_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Ignition trigger count HIJET_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2014 to 2026.
Key remind sound HIJET_KEY_REMIND_SOUND
- Service 21
PID A1 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Main idle HIJET_MAIN_IDLE_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Neutral position HIJET_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Parking brake HIJET_PARKING_BRAKE_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Pattern switch HIJET_PATTERN_SWITCH_PWR_M
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Power steering HIJET_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Reservoir warning HIJET_RESERVOIR_WARNING_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Shift SW status, drive HIJET_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Shift SW status, neutral HIJET_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Shift SW status, parking HIJET_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Shift SW status, reverse HIJET_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Slip indicator light HIJET_SLIP_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Sports mode selection HIJET_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Sports shift down HIJET_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Sports shift up HIJET_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Starter control HIJET_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Starter signal HIJET_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Steering wheel angle HIJET_STEER_ANGLEConfirmed
Positive = counter-clockwise, negative = clockwise.
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
0x6F06 = 28422 → = -434.6 °
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
TC HIJET_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Traction control, brake status HIJET_TRC_TRAC__BRAKE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Cruise control
Cruise control speed HIJET_CC_SConfirmed
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Details
Inspection mode HIJET_INSPECTION_MODE
- Service 21
PID A6 - Module
7B0 → 7B8 - Every
60 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
DTCs
2nd air monitor available? HIJET_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
2nd air monitor incomplete? HIJET_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
A/C monitor available? HIJET_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
A/C monitor incomplete? HIJET_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Catalyst monitor available? HIJET_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Catalyst monitor incomplete? HIJET_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Complete parts monitor available? HIJET_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
EGR/VVT monitor available? HIJET_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
EGR/VVT monitor incomplete? HIJET_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
EVAP monitor available? HIJET_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
EVAP monitor_icmpl HIJET_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Fuel system monitor available? HIJET_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Heated catalyst monitor available? HIJET_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Heated catalyst monitor incomplete? HIJET_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
MIL HIJET_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
MIL ON run distance HIJET_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2014 to 2026.
Misfire monitor available? HIJET_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Number of emission DTC HIJET_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2014 to 2026.
O2S heater monitor available? HIJET_O2S_A_FS_HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
O2S heater monitor incomplete? HIJET_O2S_A_FS_HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
O2S monitor available? HIJET_O2S_A_FS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
O2S monitor incomplete? HIJET_O2S_A_FS_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Running time from MIL ON HIJET_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2014 to 2026.
Electrical
B+ battery voltage HIJET_BATTERY_VOLTAGE_7C0
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1021 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20 V
- Unit
- V
In testing for 2014 to 2026.
Engine
A/F heater duty bank 1 sensor 1 HIJET_F_HEATER_DUTY_B1S1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2014 to 2026.
A/F test results 1, incomplete HIJET_F_TEST_RESULTS_1
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Accessory relay on HIJET_ACC_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Accumulator open HIJET_ACCUMULATOR_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Acoustic control induction system vacuum switching valve on HIJET_ACIS_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Actual engine torque HIJET_ACT_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2014 to 2026.
Actuator power supply on HIJET_ACTUATOR_POWER_SUP_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Air conditioning compressor HIJET_AC_COMP
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Air-fuel equivalence ratio, bank 1 sensor 1 HIJET_AF_LAMBDA_B1S1
Pelican can show this parameter as the O2 lambda.
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2014 to 2026.
Air-fuel sensor current, bank 1 sensor 1 HIJET_AFS_I_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.99 mA
- Unit
- mA
In testing for 2014 to 2026.
Air-fuel sensor voltage, bank 1 sensor 1 HIJET_AFS_V_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2014 to 2026.
Alt voltage - active test HIJET_ALT_VOL_ACTIVE_TEST
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2014 to 2026.
Alt voltage - non active test HIJET_ALT_VOL_NON_ACTIVE
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2014 to 2026.
Alternator output duty HIJET_ALTERNATOR_OUTPUT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2014 to 2026.
Atmospheric pressure HIJET_ATMOSPHERE_PRESSURE
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2014 to 2026.
Calculated load HIJET_CALCULATED_LOAD_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Catalyst temperature, bank 1 sensor 1 HIJET_CAT_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2014 to 2026.
Catalyst temperature, bank 1 sensor 2 HIJET_CAT_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2014 to 2026.
Catalyst temperature, bank 1 sensor 2, variant 2 HIJET_CAT_T_B1S2_V2
- Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2014 to 2026.
Check mode on HIJET_CHECK_MODE_ON
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Closed throttle position switch on HIJET_CLOSED_THROTTLE_POS_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Codes, include history HIJET_CODES_INCLUDE
- Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Continuously variable transmission learning complete HIJET_CVT_LEARNED
- Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2014 to 2026.
Continuously variable transmission oil pressure HIJET_CVT_OIL_P
- Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 2014 to 2026.
Coolant temperature HIJET_COOLANT_TEMP_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Cruise control on HIJET_CRUISE_CTRL_ON
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Cylinder number HIJET_CYLINDER_NUMBER
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Destination HIJET_DESTINATION
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Dist battery cable disconnect HIJET_DIST_BATT_CABLE
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2014 to 2026.
Electric fan motor on HIJET_ELEC_FAN_MOTOR_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Engine coolant temperature HIJET_ECT_7C0
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 23 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2014 to 2026.
Engine independent HIJET_ENG_INDEPENDENT
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Engine independent control HIJET_ENG_INDEPENDENT_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Engine oil temperature HIJET_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Engine run time HIJET_ENGINE_RUN_TIME
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2014 to 2026.
Engine run time, up to 255 sec. only HIJET_ENG_RUN_TIME_UP_255
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2014 to 2026.
Engine speed HIJET_ENGINE_SPEED_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Engine stall control FB flow HIJET_ENG_STALL_CTRL_FB
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 2014 to 2026.
Evaporative purge duty HIJET_EVAP_PURGE_DUTY_7E0
- Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Evaporative purge flow HIJET_EVAP_PURGE_FLOW
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.99 %
- Unit
- %
In testing for 2014 to 2026.
Evaporative purge vacuum switching valve on HIJET_EVAP_PURGE_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Exhaust gas recirculation step position HIJET_EGR_STEP_POSITION
- Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Exhaust gas recirculation temperature HIJET_EGR_T
- Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 159 °C
- Unit
- °C
In testing for 2014 to 2026.
Exhaust gas recirculation valve step HIJET_EGR_STEP
- Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Fuel cut for engine stop request HIJET_F_C_ENG_STOP_REQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Fuel cut TAU on HIJET_FC_TAU_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
G sensor calibration, complete HIJET_G_SENS_CALIBRATION
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
G sensor learning value HIJET_G_SENS_LEARNING
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2014 to 2026.
Hydraulic valve, communication open HIJET_HV_COMM_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Idle control HIJET_IDLE_CTRL
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Idle spark advance control 1 HIJET_IDLE_SPARK_ADVN_CTRL_1
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2014 to 2026.
Idle spark advance control 2 HIJET_IDLE_SPARK_ADVN_CTRL_2
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2014 to 2026.
Idle spark advance control 3 HIJET_IDLE_SPARK_ADVN_CTRL_3
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2014 to 2026.
Idle spark advance control 4 HIJET_IDLE_SPARK_ADVN_CTRL_4
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2014 to 2026.
Idle speed control learning HIJET_IDLE_SPD_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Idle speed control learning value, l/s HIJET_IDLE_SPD_CTRL_L_S
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2014 to 2026.
IG OFF elapsed time HIJET_IG_OFF_ELAPSED_TIME
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 min
- Unit
- min
In testing for 2014 to 2026.
Ignition advance HIJET_SPARKADV_21
- Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2014 to 2026.
Ignition timing advance HIJET_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2014 to 2026.
Immobilizer communication on HIJET_IMMOBILIZER_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Initial engine coolant temperature HIJET_INITIAL_ECT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.3
- Unit
- Number
In testing for 2014 to 2026.
Initial intake air temperature HIJET_INITIAL_IAT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2014 to 2026.
Injection duration for cylinder 1 HIJET_INJ_DUR_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2014 to 2026.
Injection volume per 10 injections, cylinder 1 HIJET_INJ_VOL_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.002 L
- Unit
- L
In testing for 2014 to 2026.
Injector pulse width HIJET_INJ_PW
- Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 2014 to 2026.
Injector pulse width HIJET_INJ_WIDTH
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2014 to 2026.
Input shaft speed HIJET_SPD_NIN
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Intake air temperature HIJET_IAT_21
- Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Intake air temperature HIJET_INTAKE_AIR_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Judge time engine ignition HIJET_JUDGE_TIME_ENG_IGN
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2014 to 2026.
Judge time engine output HIJET_JUDGE_TIME_ENG
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2014 to 2026.
Knock adjust HIJET_KNOCK_ADJUST
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2014 to 2026.
Knock adjust HIJET_KNOCK_ADJUST_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2014 to 2026.
Knock correct learn value HIJET_KNOCK_CORRECT_LEARN
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023 °
- Unit
- °
In testing for 2014 to 2026.
Knock feedback HIJET_KNOCK_FEEDBACK
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2014 to 2026.
Knock feedback HIJET_KNOCK_FEEDBACK_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2014 to 2026.
Long term fuel trim, bank 1 HIJET_LONG_FT_B1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2014 to 2026.
Long term fuel trim, bank 2 HIJET_LONG_FT_B2
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2014 to 2026.
Long-term fuel trim, bank 1 HIJET_LTFT1_21
- Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.15 %
- Unit
- %
In testing for 2014 to 2026.
Manifold absolute pressure HIJET_MAP_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2014 to 2026.
Mass air flow HIJET_MAF_21
- Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2014 to 2026.
Mass air flow HIJET_MAF_7E0
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2014 to 2026.
Master cylinder open HIJET_MASTER_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Misfire RPM HIJET_MISFIRE_RPM_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Misfire test result, incomplete HIJET_MIS_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Model year HIJET_MODEL_YEAR
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 1900 to 2155
- Unit
- Number
In testing for 2014 to 2026.
O2 heater b1s2_active HIJET_O2_HEATER_B1S2
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
O2 heater current val bank 1 sensor 2 HIJET_O2_HEATER_CURR_VAL
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 A
- Unit
- A
In testing for 2014 to 2026.
Open side malfunction on HIJET_OPEN_SIDE_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Output shaft speed HIJET_SPD_NOUT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2014 to 2026.
OXS1, A/FS2 test result, incomplete HIJET_OXS1_FS2_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Oxygen sensor voltage, bank 1 sensor 1 HIJET_O2S11_V
- Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.27 V
- Unit
- V
In testing for 2014 to 2026.
Oxygen sensor voltage, bank 1 sensor 2 HIJET_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 2014 to 2026.
Purge cut vacuum switching valve duty HIJET_PURGE_CUT_VSV_DUTY
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2014 to 2026.
Racing operation HIJET_RACING_OPERATION
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Request engine run time HIJET_REQ_ENG_RUN_TIME
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2014 to 2026.
Request warm-up HIJET_REQ_WARM_UP
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Requested engine torque HIJET_REQ_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383
- Unit
- Number
In testing for 2014 to 2026.
Short term fuel trim, bank 1 HIJET_SHORT_FT_B1
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2014 to 2026.
Short term fuel trim, bank 2 HIJET_SHORT_FT_B2
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2014 to 2026.
Starter relay on HIJET_STARTER_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Stroke open HIJET_STROKE_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
System guard on HIJET_SYSTEM_GUARD_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Throttle fully close learn HIJET_THROTTLE_FULLY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle idle position on HIJET_THROTTLE_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Throttle motor current HIJET_THROTTLE_MOTOR
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.9 A
- Unit
- A
In testing for 2014 to 2026.
Throttle motor duty HIJET_THROTTLE_MOTOR_DUTY
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Throttle motor duty, close HIJET_THROTTLE_MOTOR_DUTY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2014 to 2026.
Throttle motor duty, open HIJET_THROTTLE_MOTOR_DUTY_OPEN
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2014 to 2026.
Throttle position HIJET_THROTTLE_21
- Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Throttle position command HIJET_THROTTLE_POS_COMMAND
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle position, number 1 HIJET_THROTTLE_POS_NUMBER_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle position, number 2 HIJET_THROTTLE_POS_NUMBER_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle require position HIJET_THROTTLE_REQUIRE_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle sensor open position 1 HIJET_THROTTLE_SENS_OPEN_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle sensor open position 2 HIJET_THROTTLE_SENS_OPEN_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Throttle sensor position HIJET_THROTTLE_SENSOR_POSITION
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Throttle sensor voltage, 1 HIJET_THROTTLE_SENSOR_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Throttle sensor voltage, 2 HIJET_THROTTLE_SENSOR_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2014 to 2026.
Time since DTCs cleared HIJET_TIME_SINCE_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2014 to 2026.
Total fuel trim, bank 1 HIJET_TOT_FT_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 49.6 %
- Unit
- %
In testing for 2014 to 2026.
Transmission output shaft speed HIJET_TRANS_OUT_RPM
- Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Turbine speed HIJET_SPD_NT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Valvematic current angle HIJET_VALVEMATIC_CURRENT
- Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2014 to 2026.
Valvematic, target angle HIJET_VALVEMATIC_TGT_ANG
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2014 to 2026.
Variable valve timing aim angle 1 HIJET_VARIABLE_VLV_TIM_AIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2014 to 2026.
Variable valve timing change angle 1 HIJET_VARIABLE_VLV_TIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 639 °
- Unit
- °
In testing for 2014 to 2026.
Variable valve timing control status 1 on HIJET_VARIABLE_VLV_TIM_1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Variable valve timing oil control valve duty 1 HIJET_VARIABLE_VLV_TIM_OIL_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2014 to 2026.
Variable valve timing oil temperature HIJET_VVTOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Vehicle speed HIJET_VSS_21
- Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2014 to 2026.
Vehicle speed sensor test result, incomplete HIJET_SPD_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Warm-up cycles since DTCs cleared HIJET_WARMUP_CYCLES_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Misfires
All cylinders misfire count HIJET_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Cylinder #1 misfire count HIJET_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Cylinder #2 misfire count HIJET_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Cylinder #3 misfire count HIJET_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Cylinder #4 misfire count HIJET_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Misfire load HIJET_MISFIRE_LOAD_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2014 to 2026.
Misfire margin HIJET_MISFIRE_MARGIN_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2014 to 2026.
Fluids
Distance since oil change HIJET_OIL_CHANGE_ODO
- Service 21
PID 41 - Module
7C0 → 7C8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 41038.272 km
- Unit
- km
In testing for 2014 to 2026.
Fuel
Fuel cut HIJET_FUEL_CUT
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Fuel cut HIJET_FUEL_CUT_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 121 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Fuel cut time HIJET_FUEL_CUT_TIME
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 68734.9511
- Unit
- Number
In testing for 2014 to 2026.
Fuel injection timing HIJET_FUEL_INJ_TIM
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2014 to 2026.
Fuel level HIJET_FUEL_LEVEL
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1022 - Module
7C0 → 7C8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2014 to 2026.
Fuel level, volume HIJET_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 21
PID 29 - Module
7C0 → 7C8 - Every
5 s - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 21 gal
- Unit
- gal
0x14 = 20 → = 2.642008 gal
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Fuel pump/speed status on HIJET_FUEL_PMP_SPD_STAT_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Target air-fuel equivalence ratio HIJET_LAMBDA_TARGET
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2014 to 2026.
Lights
Check engine SW HIJET_CHECK_ENGINE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Hazard switch history HIJET_HAZARD_SWITCH_HISTORY
- Service 21
PID BC - Module
7B0 → 7B8 - Every
3600 s - Testing
Bit 2 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | INCOMPLETE | Incomplete |
1 | COMPLETE | Complete |
In testing for 2014 to 2026.
Oil pressure switch HIJET_EOP_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
P-seatbelt buckle SW HIJET_P_SEATBELT_BUCKLE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rheostat HIJET_RHEOSTAT
Higher values are brighter
- Service 21
PID 68 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Stop light HIJET_STOP_LIGHT_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Stop light HIJET_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Stop light relay HIJET_STOP_LIGHT_RELAY
- Service 21
PID 3C - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Tail cancel SW HIJET_TAIL_CANCEL_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Movement
Accelerator fully close learn 1 HIJET_ACCEL_FULLY_CLOSE_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2014 to 2026.
Accelerator fully close learn 2 HIJET_ACCEL_FULLY_CLOSE_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2014 to 2026.
Accelerator idle position on HIJET_ACCEL_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 148 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Accelerator position HIJET_ACCEL_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2014 to 2026.
Accelerator sensor out, number 1 HIJET_ACCEL_SENS_OUT_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Accelerator sensor out, number 2 HIJET_ACCEL_SENS_OUT_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2014 to 2026.
Average engine speed of all cylinders HIJET_AV_RPM_ALL_CYL
Pelican can show this parameter as the engine speed.
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Cruise control speed HIJET_CRUISE_CTRL_SPD
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2014 to 2026.
Engine speed of cylinder 1 HIJET_RPM_CYL_1
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Engine speed of cylinder 2 HIJET_RPM_CYL_2
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Engine speed of cylinder 3 HIJET_RPM_CYL_3
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Engine speed of cylinder 4 HIJET_RPM_CYL_4
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Front left wheel acceleration HIJET_FL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Front left wheel speed HIJET_TIRE_FL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Front left wheel speed? HIJET_FL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Front right wheel acceleration HIJET_FR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Front right wheel speed HIJET_TIRE_FR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Front right wheel speed? HIJET_FR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
High voltage, target engine speed HIJET_HIGH_V_TGT_RPM
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Minimum engine speed HIJET_MIN_RPM
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2014 to 2026.
Rear left wheel acceleration HIJET_RL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Rear left wheel speed HIJET_TIRE_RL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Rear left wheel speed? HIJET_RL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Rear right wheel acceleration HIJET_RR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Rear right wheel speed HIJET_TIRE_RR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Rear right wheel speed? HIJET_RR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Speed HIJET_VSS_7C0
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7C0 → 7C8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2014 to 2026.
Vehicle speed HIJET_VEHICLE_SPEED_7E0
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2014 to 2026.
Vehicle speed HIJET_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7B0 → 7B8 - Every
200 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 323.85 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Orientation
Deceleration HIJET_DECEL
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Deceleration 2 HIJET_DECEL_2
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2014 to 2026.
Deceleration open HIJET_DECELERATION_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Lateral g HIJET_LAT_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Longitudinal g HIJET_LNG_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Yaw rate value, degrees/sec HIJET_YAW_RATEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2014 to 2022, 2024 to 2026
Example reply from a 2023 Daihatsu Hijet.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x74 = 116 → = -12 °
Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.
Yaw rate, error? HIJET_YAW_RATE_OPEN_ERROR
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Yaw rate, sensor 1 HIJET_YAW_1
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2014 to 2026.
Yaw rate, sensor 2 HIJET_YAW_2
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2014 to 2026.
Zero point of deceleration HIJET_ZP_DEC
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2014 to 2026.
Zero point of deceleration 2 HIJET_ZP_DEC2
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2014 to 2026.
Zero point of yaw rate HIJET_ZERO_POINT_OF_YAW_RATE
- Service 21
PID A1 - Module
7B0 → 7B8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2014 to 2026.
Zero point of yaw rate, degrees/sec HIJET_ZP_YAW
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2014 to 2026.
Seatbelts
Reverse beep HIJET_REVERSE_BEEP
- Service 21
PID AC - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- On or off
In testing for 2014 to 2026.
Seat belt beep, driver HIJET_SEAT_BELT_BEEP_DRIVER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Seat belt beep, passenger HIJET_SEAT_BELT_BEEP_PASSENGER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Seat belt beep, reminder HIJET_SEAT_BELT_BEEP_REMINDER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Tires
Brake assist status HIJET_BA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Front left wheel ABS status HIJET_FL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Front left wheel vehicle stability control status HIJET_FL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Front right wheel ABS status HIJET_FR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Front right wheel cylinder open HIJET_FR_WHEEL_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2014 to 2026.
Front right wheel vehicle stability control status HIJET_FR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Predictive brake assist status HIJET_PBA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear left wheel ABS status HIJET_RL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear left wheel EBS status HIJET_RL_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear left wheel vehicle stability control status HIJET_RL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear right wheel ABS status HIJET_RR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear right wheel EBS status HIJET_RR_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Rear right wheel vehicle stability control status HIJET_RR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Traction control, engine status HIJET_TRC_TRAC__ENGINE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Traction control, status HIJET_TRC_TRAC__CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2026.
Wheel cylinder pressure HIJET_WHEEL_CYLINDER_PRESSURE
- Service 21
PID 07 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2014 to 2026.
Transmission
Current gear HIJET_GEAR_V2
- Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2026.
Torque converter and TE1 on HIJET_TQ_CONV_TE1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Transmission fluid temperature, variant 5 HIJET_ATF_T_V_5
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2014 to 2026.
Transmission fluid temperature, variant 8 HIJET_ATF_T_V_8
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2014 to 2026.
Transmission fluid temperature, variant 14 HIJET_ATF_T_V_14
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2014 to 2026.
Transmission fluid temperature, variant 21 HIJET_ATF_T_V_21
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2026.
Transmission oil pressure calibration, complete HIJET_TRANS_OIL_PRESS
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2014 to 2026.
Trips
Odometer HIJET_ODO
Pelican can show this parameter as the odometer.
- Service 21
PID 28 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2014 to 2026.
Previous trip distance HIJET_PREV_TRIP_DST
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
In testing for 2014 to 2026.