Genesis G70

Parameters

The Genesis G70 has 440 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge G70_BATTERY_SOC

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery state of charge G70_BATTERY_SOC

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Aux battery state of charge G70_AUX_SOC

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Aux battery state of health G70_AUX_SOH

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Available charge power G70_BMS_CHG_PWR

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 2017 to 2026.

Available discharge power G70_BMS_DISCHG_PWR

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 2017 to 2026.

Battery capacity, battery sensor G70_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2017 to 2026.

Battery charge flag, battery sensor G70_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery current G70_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2017 to 2026.

Battery current, battery sensor G70_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2017 to 2026.

Battery current, battery sensor G70_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2017 to 2026.

Battery health aging flag, battery sensor G70_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery is in use to crank the engine flag, battery sensor G70_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery min temp G70_BMS_MIN_TEMP

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Battery mod 1 temp G70_BMS_MOD1_TEMP

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Battery mod 2 temp G70_BMS_MOD2_TEMP

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Battery mod 3 temp G70_BMS_MOD3_TEMP

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Battery mod 4 temp G70_BMS_MOD4_TEMP

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Battery quiescent current flag, battery sensor G70_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery sensor invalid condition flag, battery sensor G70_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery state of charge, battery sensor G70_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Battery state of charge, battery sensor G70_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Battery state of function, battery sensor G70_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2017 to 2026.

Battery state of health, battery sensor G70_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Battery state of health, battery sensor G70_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Battery temperature G70_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2017 to 2026.

Battery temperature, battery sensor G70_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Battery temperature, battery sensor G70_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2017 to 2026.

Battery voltage G70_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2017 to 2026.

Battery voltage G70_BATTERY_V

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

In testing for 2017 to 2026.

Battery voltage after ignition G70_BATTERY_V_AFTER_IGNITION

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

In testing for 2017 to 2026.

Battery voltage, battery sensor G70_BAT_V_BATSENS

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2017 to 2026.

Battery voltage, battery sensor G70_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2017 to 2026.

Gasoline particulate filter charge state G70_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Gasoline particulate filter inlet temperature sensor raw voltage G70_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2017 to 2026.

Gasoline particulate filter outlet temperature sensor raw voltage G70_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2017 to 2026.

Relative accelerator pedal position voltage G70_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2017 to 2026.

Response error from battery sensor flag, battery sensor G70_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

State of charge G70_BMS_SOC

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Throttle position sensor voltage #1 G70_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2017 to 2026.

Throttle position sensor voltage #2 G70_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2017 to 2026.

Waste gate voltage G70_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2017 to 2026.

Wastegate position voltage G70_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2017 to 2026.

Climate

Ambient temperature, vehicle control unit G70_AAT_VMCU

  • Service 21PID 80
  • Module7E6 → 7EE
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val2−40
Range
-104 to 23.5 °C
Unit
°C

In testing for 2017 to 2026.

Defogging? G70_DEFOG_SW

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Evaporator temperature G70_HVAC_EVAPORATOR_T

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Exterior temperature G70_TEMP_EXT

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Heated steering wheel G70_HEATED_WHEEL

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Heated steering wheel, alternate bit G70_HEATED_WHEEL_ALT

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Humidity sensor for automatic defogger G70_HVAC_DEFOG_HUMIDITY

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Interior temperature G70_TEMP_INT

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 80 °C
Unit
°C

In testing for 2017 to 2026.

Interior temperature, passenger legs vent G70_HVAC_IAT_PASSENGER_LEGS_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Interior temperature, passenger vent G70_HVAC_IAT_PASSENGER_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Control

Brake booster pressure G70_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2017 to 2026.

Brake pedal G70_BRAKE_PEDAL

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Brake pressure G70_BRAKE_P

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Brake pressure G70_BRAKE_P_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Brake switch G70_BRAKE_SW

  • Service 22DID B008
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Handbrake engaged? G70_HANDBRAKE

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Steering wheel angle G70_STEER_ANGLE

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2017 to 2026.

Steering wheel angle G70_STEER_ANGLE_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2017 to 2026.

Steering wheel angle G70_STEER_ANGLE_V3

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2017 to 2026.

Steering wheel angle G70_STEERING_ANGLE

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2017 to 2026.

Doors

Front left door locked? G70_LOCK_FL

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2017 to 2026.

Front left door open? G70_DOOR_FL

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Front right door locked? G70_LOCK_FR

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2017 to 2026.

Front right door open? G70_DOOR_FR

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Hood latched? G70_HOOD

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Rear left door open? G70_DOOR_RL

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 39 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Rear right door open? G70_DOOR_RR

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Trunk open? G70_TRUNK

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Electrical

Cluster voltage G70_CLUSTER_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

In testing for 2017 to 2026.

Engine

4WD clutch duty G70_AWD_CLU_DUTY

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 %
Unit
%

In testing for 2017 to 2026.

4WD clutch pressure G70_AWD_CLU_P

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
val×0.001953
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2017 to 2026.

4WD clutch stress G70_AWD_CLU_STRESS

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val×0.001953
Range
-63.99 to 63.99 %
Unit
%

In testing for 2017 to 2026.

4WD clutch torque G70_AWD_CLU_TQ

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 N·m
Unit
N·m

In testing for 2017 to 2026.

4WD front axle ratio G70_AWD_FRONT_AXLE_RAT

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val×265535
Range
-1 to 0.999
Unit
Number

In testing for 2017 to 2026.

Adaptation value for lower stop of wastegate actuator G70_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2017 to 2026.

Air conditioning pressure G70_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×3520255
Range
0 to 3520 kPa
Unit
kPa

In testing for 2017 to 2026.

Air conditioning relay G70_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Automatic transmission fluid temperature G70_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Barometric pressure G70_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2017 to 2026.

Boost pressure G70_BOOST_P_7E0

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream G70_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream, desired G70_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Butane in liquefied petroleum gas G70_BUTANE_LPG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Calculated oil temperature G70_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Camshaft exhaust position, actual G70_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft exhaust position, commanded G70_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, actual G70_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, commanded G70_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Catalyst damaging misfires total all cylinders G70_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total all cylinders G70_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 G70_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 G70_CATDMG_MIS_TOT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 G70_CATDMG_MIS_TOT_1_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 G70_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 G70_CATDMG_MIS_TOT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 G70_CATDMG_MIS_TOT_2_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 G70_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 G70_CATDMG_MIS_TOT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 G70_CATDMG_MIS_TOT_3_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 G70_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 G70_CATDMG_MIS_TOT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 G70_CATDMG_MIS_TOT_4_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 5 G70_CATDMG_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 6 G70_CATDMG_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Commanded evaporative purge G70_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2017 to 2026.

Commanded throttle actuator G70_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2017 to 2026.

Coolant G70_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Coolant fan PWM G70_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Coolant temperature G70_HVAC_COOLANT_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Coverage driven length G70_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Crankshaft torque G70_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2017 to 2026.

Cylinder 1 injection time, 1st pulse G70_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 1 injection time, 2nd pulse G70_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 1st pulse G70_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 2nd pulse G70_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 1st pulse G70_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 2nd pulse G70_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 1st pulse G70_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 2nd pulse G70_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Diesel particulate filter regeneration count G70_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter regeneration state G70_DPF_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Diesel particulate filter successful regeneration count G70_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Direct injection time 1 G70_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 1 G70_DI_TIME_1ST_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 2 G70_DI_TIME_1ST_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 3 G70_DI_TIME_1ST_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 4 G70_DI_TIME_1ST_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 5 G70_CYL5_INJ_TIME_1ST

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 6 G70_CYL6_INJ_TIME_1ST

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2 G70_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 1 G70_DI_TIME_2ND_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 2 G70_DI_TIME_2ND_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 3 G70_DI_TIME_2ND_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 4 G70_DI_TIME_2ND_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 5 G70_CYL5_INJ_TIME_2ND

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 6 G70_CYL6_INJ_TIME_2ND

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 3 G70_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 4 G70_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 5 G70_DI_TIME_5

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 6 G70_DI_TIME_6

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a G70_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b G70_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 1 G70_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 2 G70_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission line pressure, sensor c G70_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders G70_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders G70_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 G70_EMIS_MIS_TOT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 G70_EMIS_MIS_TOT_1_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 G70_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 G70_EMIS_MIS_TOT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 G70_EMIS_MIS_TOT_2_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 G70_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 G70_EMIS_MIS_TOT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 G70_EMIS_MIS_TOT_3_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 G70_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 G70_EMIS_MIS_TOT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 G70_EMIS_MIS_TOT_4_7E0

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 G70_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 5 G70_EMIS_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 6 G70_EMIS_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Engine oil temperature G70_EOT

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val1.3333−48
Range
0 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature G70_EOT_7E0

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature G70_EOT_V2

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251 °C
Unit
°C

In testing for 2017 to 2026.

Engine run time, total G70_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2017 to 2026.

Engine, actual torque G70_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2.3529
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2017 to 2026.

Exhaust cam oil control valve duty G70_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Exhaust camshaft position G70_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Exhaust gas temperature G70_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 1 G70_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 G70_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst G70_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust temperature 2, upstream of DPF G70_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Front left tire temperature G70_FL_TT

Pelican can show this parameter as the front left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Front right tire temperature G70_FR_TT

Pelican can show this parameter as the front right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 1 G70_GDI_IT_A1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 2 G70_GDI_IT_A2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 3 G70_GDI_IT_A3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 4 G70_GDI_IT_A4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 1 G70_GDI_IT_B1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 2 G70_GDI_IT_B2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 3 G70_GDI_IT_B3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 4 G70_GDI_IT_B4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Idle control mode G70_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Ignition retard due to knock control 1 G70_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 2 G70_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 3 G70_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 4 G70_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Injection duration cylinder 1 G70_INJ_DUR_1

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 2 G70_INJ_DUR_2

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 3 G70_INJ_DUR_3

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 4 G70_INJ_DUR_4

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 5 G70_INJ_DUR_5

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 6 G70_INJ_DUR_6

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.68 ms
Unit
ms

In testing for 2017 to 2026.

Injector correction factor 1 G70_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 2 G70_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 3 G70_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 4 G70_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Intake air temperature G70_IAT

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val1.3333−48
Range
0 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Intake cam oil control valve duty G70_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Intake camshaft position G70_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Intake camshaft position actual G70_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Intake camshaft position commanded G70_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2017 to 2026.

Inverter temperature G70_HVAC_INVERTER_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Knock detected G70_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Knock learn cylinder 1 G70_KNOCK_LEARN_1

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 2 G70_KNOCK_LEARN_2

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 3 G70_KNOCK_LEARN_3

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 4 G70_KNOCK_LEARN_4

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #1 G70_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #2 G70_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #3 G70_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #4 G70_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1 G70_KNOCK_RETARD_1

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1 G70_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1, alternate G70_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1, alternate G70_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 G70_KNOCK_RETARD_2

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 G70_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2, alternate G70_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2, alternate G70_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 G70_KNOCK_RETARD_3

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 G70_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3, alternate G70_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3, alternate G70_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 G70_KNOCK_RETARD_4

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 G70_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4, alternate G70_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4, alternate G70_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Liquefied petroleum gas low side temperature G70_LPG_LOW_SIDE_T

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Main injection volume G70_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2017 to 2026.

Mass air flow rate G70_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2017 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running G70_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G70_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running G70_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G70_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Misfire count #1 G70_MIS_1

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #2 G70_MIS_2

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #3 G70_MIS_3

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #4 G70_MIS_4

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires current total G70_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 1 G70_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 2 G70_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 3 G70_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 4 G70_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 5 G70_MIS_CURRENT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 6 G70_MIS_CURRENT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 1 G70_MISFIRES_C1_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 2 G70_MISFIRES_C2_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 3 G70_MISFIRES_C3_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 4 G70_MISFIRES_C4_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Motor-driven power steering current G70_MDPS_MOTOR_CURRENT

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

In testing for 2017 to 2026.

Oil pump PWM G70_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2017 to 2026.

Oxygen sensor 1 bank 1 G70_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2017 to 2026.

Oxygen sensor 2 bank 1 G70_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2017 to 2026.

Parking sensor rear center left level G70_PARKING_SENS_REAR

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Parking sensor rear center right level G70_PARKING_SENS_REAR_CENTER

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Pilot injection volume G70_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2017 to 2026.

Post injection volume G70_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2017 to 2026.

Rear left tire temperature G70_RL_TT

Pelican can show this parameter as the rear left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Rear right tire temperature G70_RR_TT

Pelican can show this parameter as the rear right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Requested torque G70_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Requested torque limitation from traction control G70_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Throttle position #1 G70_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2017 to 2026.

Throttle position #2 G70_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2017 to 2026.

Timing advance #1 G70_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #2 G70_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #3 G70_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #4 G70_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Torque converter slip G70_TORQUE_CONVERTER_SLIP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque converter slip G70_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque, actual G70_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2017 to 2026.

Transmission fluid temperature G70_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Turbo boost gauge pressure G70_TURBO_BOOST

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val831.556909−12
Range
-10 to 66.81 psi
Unit
psi

In testing for 2017 to 2026.

Turbo boost pressure G70_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2017 to 2026.

Turbo boost pressure G70_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2017 to 2026.

Variable valve timing temperature G70_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2017 to 2026.

Waste gate duty G70_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2017 to 2026.

Waste gate duty G70_WG_DUTY

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×20065535
Range
0 to 200 %
Unit
%

In testing for 2017 to 2026.

Waste gate position G70_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate position G70_WG_POSITION

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 199.99 %
Unit
%

In testing for 2017 to 2026.

Waste gate set point G70_WG_SETPOINT

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 100 %
Unit
%

In testing for 2017 to 2026.

Waste gate target G70_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate voltage G70_WG_VOLTAGE

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×1065535
Range
0 to 10 V
Unit
V

In testing for 2017 to 2026.

Wastegate control PWM, wastegate actuator G70_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2017 to 2026.

Wastegate position target, wastegate actuator G70_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2017 to 2026.

Wastegate position, wastegate actuator G70_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2017 to 2026.

Misfires

Emission-relevant misfires, cylinder #1 G70_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #2 G70_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #3 G70_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #4 G70_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 1 G70_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 2 G70_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 3 G70_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 4 G70_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, all cylinders G70_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #1 G70_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #2 G70_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #3 G70_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #4 G70_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 1 G70_MIS_1_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 2 G70_MIS_2_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 3 G70_MIS_3_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 4 G70_MIS_4_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Unknown

Unknown G70_22E004

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2017 to 2026.

Fuel

Fuel consumption since last DPF regeneration G70_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2017 to 2026.

Fuel cut G70_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Fuel injection timing #1 G70_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2017 to 2026.

Fuel injection timing #2 G70_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2017 to 2026.

Fuel injection timing #3 G70_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2017 to 2026.

Fuel injection timing #4 G70_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2017 to 2026.

Fuel level G70_FLI_VOL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

In testing for 2017 to 2026.

Fuel level input G70_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2017 to 2026.

Fuel pressure G70_FUEL_P

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6110000
Range
0 to 399.7635
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure G70_FUEL_P_7E0

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure deviation G70_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure set point G70_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure target G70_FUEL_P_TGT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6110000
Range
0 to 399.7635
Unit
Raw value

In testing for 2017 to 2026.

Fuel temperature G70_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Liquefied petroleum gas electrical fuel pump PWM G70_LPG_ELECTRICAL_FUEL

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Liquefied petroleum gas pressure in fuel rail, average G70_LPG_P_FUEL_RAIL_AVG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2017 to 2026.

Short term fuel % trim, bank 1 G70_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2017 to 2026.

Short term fuel % trim, bank 1 idle G70_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Lights

Brake light G70_BRAKE_LIGHT

  • Service 22DID BC06
  • Module770 → 778
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Defog light G70_DEFOG_LIGHT

  • Service 22DID BC07
  • Module770 → 778
  • Every5 s
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Exterior lights state code G70_LIGHTS_CODE

  • Service 22DID BC10
  • Module770 → 778
  • Every5 s
  • Testing

Bits 32 to 35 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2017 to 2026.

Hazard switch G70_HAZARD_SW

  • Service 22DID BC05
  • Module770 → 778
  • Every2 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Headlight high beam G70_HL_HIGH

  • Service 22DID BC09
  • Module770 → 778
  • Every2 s
  • Testing

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Headlight low beam G70_HL_LOW

  • Service 22DID BC09
  • Module770 → 778
  • Every2 s
  • Testing

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Headlight switch G70_HL_SW

  • Service 22DID BC05
  • Module770 → 778
  • Every2 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Left turn signal on? G70_TURN_L

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Right turn signal on? G70_TURN_R

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Movement

4WD delta speed between front and rear axle G70_AWD_AXLE_SPD_DIFF

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 rpm
Unit
rpm

In testing for 2017 to 2026.

Actual acceleration G70_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2017 to 2026.

Average wheel speed G70_VSS_AVG_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Coolant fan high speed G70_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Coolant fan high speed, 1.8 G70_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Coolant fan low speed G70_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Coolant fan low speed, 1.8 G70_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Engine coolant fan high speed, on/off G70_ENG_CLT_FAN_HIGH_SPD_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Engine coolant fan low speed G70_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Engine RPM G70_RPM_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Front left wheel speed G70_FL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 km/h
Unit
km/h

In testing for 2017 to 2026.

Front left wheel speed G70_TIRE_FL_VSS_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Front left wheel speed G70_TIRE_FL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Front left wheel speed, high resolution G70_WHEEL_FL_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2017 to 2026.

Front right wheel speed G70_FR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 km/h
Unit
km/h

In testing for 2017 to 2026.

Front right wheel speed G70_TIRE_FR_VSS_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Front right wheel speed G70_TIRE_FR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Front right wheel speed, high resolution G70_WHEEL_FR_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2017 to 2026.

Output speed G70_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Output speed G70_OUTPUT_SPEED

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Rear left wheel speed G70_RL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear left wheel speed G70_TIRE_RL_VSS_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear left wheel speed G70_TIRE_RL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear left wheel speed, high resolution G70_WHEEL_RL_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear right wheel speed G70_RR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear right wheel speed G70_TIRE_RR_VSS_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear right wheel speed G70_TIRE_RR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear right wheel speed, high resolution G70_WHEEL_RR_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2017 to 2026.

Relative accelerator pedal position G70_REL_APP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Relative accelerator pedal position G70_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2017 to 2026.

Traction control switch G70_TC_SWITCH_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Turbine speed G70_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Turbine speed G70_TURBINE_SPEED

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Vehicle speed G70_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Vehicle speed G70_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Vehicle speed G70_VSS_AVG

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Vehicle speed G70_VSS_V3

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Vehicle speed, v2 G70_VSS_V2_7E0

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2017 to 2026.

Wheel traction control switch G70_TC_SWITCH

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Orientation

Lateral acceleration G70_LATERAL_ACCELERATION

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.1769 to 4.1769 m/s²
Unit
m/s²

In testing for 2017 to 2026.

Longitudinal acceleration G70_LONGITUDINAL_ACCELERATION

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.1769 to 4.1769 m/s²
Unit
m/s²

In testing for 2017 to 2026.

Yaw rate G70_YAW_RATE

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 °
Unit
°

In testing for 2017 to 2026.

Seatbelts

Driver seatbelt latched? G70_BELT_DRIV

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Passenger seatbelt latched? G70_BELT_PASS

  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Rear left seatbelt latched? G70_BELT_RL

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Rear middle seatbelt latched? G70_BELT_RM

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 52 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Rear right seatbelt latched? G70_BELT_RR

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Tires

4WD steering wheel angle G70_AWD_STEER_WHL_ANG

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 184 to 199 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 °
Unit
°

In testing for 2017 to 2026.

Front left tire pressure G70_FL_TP

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2017 to 2026.

Front left wheel speed G70_FL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Front right tire pressure G70_FR_TP

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2017 to 2026.

Front right wheel speed G70_FR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear left tire pressure G70_RL_TP

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2017 to 2026.

Rear left wheel speed G70_RL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Rear right tire pressure G70_RR_TP

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2017 to 2026.

Rear right wheel speed G70_RR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Tire pressure front left G70_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2017 to 2026.

Tire pressure front right G70_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2017 to 2026.

Tire pressure rear left G70_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2017 to 2026.

Tire pressure rear right G70_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2017 to 2026.

Tire sensor 1 ID G70_TID_1

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2017 to 2026.

Tire sensor 2 ID G70_TID_2

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2017 to 2026.

Tire sensor 3 ID G70_TID_3

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2017 to 2026.

Tire sensor 4 ID G70_TID_4

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2017 to 2026.

Tire temperature front left G70_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Tire temperature front right G70_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Tire temperature rear left G70_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Tire temperature rear right G70_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2026.

Transmission

Automatic transmission fluid temperature G70_ATF_T

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Clutch #1 temperature G70_CLUTCH_1_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2017 to 2026.

Clutch #2 temperature G70_CLUTCH_2_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2017 to 2026.

Commanded gear G70_COMMANDED_GEAR

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Current gear G70_CURRENT_GEAR

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Current gear G70_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Current gear G70_GEAR

The automatic transmission gear.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1NEUTRALNeutral
2REVERSEReverse
3PARKPark
4MANUALManual

In testing for 2017 to 2026.

Current gear G70_GEAR_CUR

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2017 to 2026.

Dual-clutch transmission even shaft, gear engaged G70_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Dual-clutch transmission odd shaft, gear engaged G70_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Gear G70_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Gear selector G70_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Next gear G70_GEAR_NXT

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2017 to 2026.

Reverse gear selected G70_GEAR_R

  • Service 22DID BC04
  • Module770 → 778
  • Every2 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2017 to 2026.

Transmission fluid temperature G70_ATF_TEMP

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2017 to 2026.

Trips

Diesel particulate filter distance since last regeneration G70_DPF_DIST_SINCE_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Diesel particulate filter odometer at last regeneration G70_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Distance since last DPF regeneration G70_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Distance since last gasoline particulate filter regeneration G70_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer G70_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer G70_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer at last DPF regeneration G70_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer at last gasoline particulate filter regeneration G70_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer, imperial G70_ODO_MI

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

In testing for 2017 to 2026.

Odometer, metric G70_ODO_KM

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2017 to 2026.

Sensor #1 odometer event #1 G70_SENS_1_ODO_EVT_1

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #1 odometer event #2 G70_SENS_1_ODO_EVT_2

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #1 odometer event #3 G70_SENS_1_ODO_EVT_3

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #2 odometer event #1 G70_SENS_2_ODO_EVT_1

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #2 odometer event #2 G70_SENS_2_ODO_EVT_2

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #2 odometer event #3 G70_SENS_2_ODO_EVT_3

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #3 odometer event #1 G70_SENS_3_ODO_EVT_1

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #3 odometer event #2 G70_SENS_3_ODO_EVT_2

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #3 odometer event #3 G70_SENS_3_ODO_EVT_3

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #4 odometer event #1 G70_SENS_4_ODO_EVT_1

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #4 odometer event #2 G70_SENS_4_ODO_EVT_2

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Sensor #4 odometer event #3 G70_SENS_4_ODO_EVT_3

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2017 to 2026.

Vehicle total distance G70_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2017 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.