Parameters
The Haval Jolion has 69 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery voltage JOLION_BATTERY_VOLTAGE
- Service 22
DID 1702 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 31.875 V
- Unit
- V
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Climate
A/C pressure JOLION_AC_PRESSURE_HVAC
- Service 22
DID 1469 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095.875 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
A/C pressure, enhanced JOLION_AC_PRESSURE_HVAC2Confirmed
- Service 22
DID 210C - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Drivetrain
Engine net torque JOLION_TRANSMISSION_ENGINE_NET_TORQUE
- Service 22
DID 6915 - Module
7E1 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -510 to 65025 N·m
- Unit
- N·m
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Engine torque JOLION_TRANSMISSION_ENGINE_TORQUE
- Service 22
DID 6915 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -512 to 508 N·m
- Unit
- N·m
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Engine
Boost pressure JOLION_BOOST_PRESSURE_VALUEConfirmed
- Service 22
DID 016A - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Boost pressure, actual JOLION_BP_ACTUALConfirmed
- Service 22
DID 010F - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x26B8 = 9912 → = 77.4375 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Boost pressure, target JOLION_BP_TARGETConfirmed
- Service 22
DID 0112 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Injection pulse width JOLION_INJECTION_PULSE_WIDTHConfirmed
- Service 22
DID 016D - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 ms
- Unit
- ms
0x00000000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock counter JOLION_KNOCK_COUNTER
- Service 22
DID 11A0 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard JOLION_KNOCK_RETARD
- Service 22
DID 11A6 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 22.491 °
- Unit
- °
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 1 JOLION_INJECTION_KNOCK_RETARD_CYL_1Confirmed
- Service 22
DID 0170 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard cylinder 2 JOLION_INJECTION_KNOCK_RETARD_CYL_2Confirmed
- Service 22
DID 0171 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard cylinder 3 JOLION_INJECTION_KNOCK_RETARD_CYL_3Confirmed
- Service 22
DID 0172 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard cylinder 4 JOLION_INJECTION_KNOCK_RETARD_CYL_4Confirmed
- Service 22
DID 0173 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor reference voltage cylinder 1 JOLION_KNOCK_SENSOR_REFERENCE_CYL_1Confirmed
- Service 22
DID 0174 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99704375 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor reference voltage cylinder 2 JOLION_KNOCK_SENSOR_REFERENCE_CYL_2Confirmed
- Service 22
DID 0175 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99704375 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor reference voltage cylinder 3 JOLION_KNOCK_SENSOR_REFERENCE_CYL_3Confirmed
- Service 22
DID 0176 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99704375 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor reference voltage cylinder 4 JOLION_KNOCK_SENSOR_REFERENCE_CYL_4Confirmed
- Service 22
DID 0177 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99704375 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfire current, total JOLION_MISFIRE_CURRENT_TOTAL
- Service 22
DID 1200 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 65280
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Oil pressure JOLION_OIL_PRESSURE
- Service 22
DID FD19 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.984375 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Oil temperature JOLION_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1602 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Oil temperature, model JOLION_OIL_TConfirmed
- Service 22
DID 0107 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 6280.35 °C
- Unit
- °C
0x0B59 = 2905 → = 17.35 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet pressure, model JOLION_PRESSURE_BEFORE_TURBOCHARGERConfirmed
- Service 22
DID 0113 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x26D1 = 9937 → = 77.632813 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet temperature, model JOLION_AIR_T_BEFORE_TURBOCHARGERConfirmed
- Service 22
DID 0114 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
0x56C8 = 22216 → = 247.526392 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Variable clutch pressure control, min oil temperature JOLION_OT_VCPC_MIN
- Service 22
DID 1603 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires
Misfire current cylinder 1 JOLION_MISFIRE_CURRENT_CYL_1
- Service 22
DID 1206 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire current cylinder 2 JOLION_MISFIRE_CURRENT_CYL_2
- Service 22
DID 1205 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire current cylinder 3 JOLION_MISFIRE_CURRENT_CYL_3
- Service 22
DID 1207 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire current cylinder 4 JOLION_MISFIRE_CURRENT_CYL_4
- Service 22
DID 1208 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire history cylinder 1 JOLION_MISFIRE_HISTORY_CYL_1
- Service 22
DID 1201 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire history cylinder 2 JOLION_MISFIRE_HISTORY_CYL_2
- Service 22
DID 1202 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire history cylinder 3 JOLION_MISFIRE_HISTORY_CYL_3
- Service 22
DID 1203 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire history cylinder 4 JOLION_MISFIRE_HISTORY_CYL_4
- Service 22
DID 1204 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires cylinder 1 JOLION_MISFIRES_CYL_1Confirmed
- Service 22
DID 0180 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires cylinder 2 JOLION_MISFIRES_CYL_2Confirmed
- Service 22
DID 0183 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires cylinder 3 JOLION_MISFIRES_CYL_3Confirmed
- Service 22
DID 0181 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires cylinder 4 JOLION_MISFIRES_CYL_4Confirmed
- Service 22
DID 0182 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires total JOLION_MISFIRES_TOTALConfirmed
- Service 22
DID 017F - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel
Fuel flow JOLION_FUEL_FLOWConfirmed
- Service 22
DID 0111 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 281.2473846 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel level JOLION_FUEL_LEVEL_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 002F - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Fuel level, liters JOLION_FUEL_LEVEL_LITERSConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 0106 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
0x0046 = 70 → = 7 L
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel level, output JOLION_FUEL_LEVEL_OUTPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 12C5 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Movement
Front left wheel speed JOLION_FRONT_LEFT_VSSConfirmed
- Service 22
DID 6303 - Module
782 → 7C2 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686.34375 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Front right wheel speed JOLION_FRONT_RIGHT_VSSConfirmed
- Service 22
DID 6303 - Module
782 → 7C2 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686.34375 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Rear left wheel speed JOLION_REAR_LEFT_VSSConfirmed
- Service 22
DID 6303 - Module
782 → 7C2 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686.34375 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Rear right wheel speed JOLION_REAR_RIGHT_VSSConfirmed
- Service 22
DID 6303 - Module
782 → 7C2 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686.34375 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Transmission electric pump speed JOLION_TRANSMISSION_ELECTRIC_PUMP_SPEED
- Service 22
DID 6A1A - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission even axis speed JOLION_TRANSMISSION_EVEN_AXIS_SPEED
- Service 22
DID 6903 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission input shaft speed JOLION_TRANSMISSION_INPUT_SHAFT_SPEED
- Service 22
DID 690D - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission odd axis speed JOLION_TRANSMISSION_ODD_AXIS_SPEED
- Service 22
DID 6902 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission
Clutch 1 pressure JOLION_TRANSMISSION_CLUTCH_1_PRESSURE
- Service 22
DID 690B - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 6353.5 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clutch 1 torque JOLION_TRANSMISSION_CLUTCH_1_TORQUE
- Service 22
DID 6932 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4080 N·m
- Unit
- N·m
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clutch 2 pressure JOLION_TRANSMISSION_CLUTCH_2_PRESSURE
- Service 22
DID 690C - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 6353.5 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clutch 2 torque JOLION_TRANSMISSION_CLUTCH_2_TORQUE
- Service 22
DID 6933 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4080 N·m
- Unit
- N·m
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clutch temperature JOLION_TRANSMISSION_CLUTCH_TEMP
- Service 22
DID 6934 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 965 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clutch temperature v2 JOLION_TRANSMISSION_CLUTCH_TEMP_V1
- Service 22
DID 6A0A - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 965 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Current gear JOLION_GEARConfirmed
- Service 22
DID 0132 - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Current gear JOLION_TRANSMISSION_CURRENT_GEAR
- Service 22
DID 6925 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Even clutch actual pressure JOLION_TRANSMISSION_EVEN_CLUTCH_ACTUAL_PRESSURE
- Service 22
DID 690C - Module
7E1 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -2000 to 63535 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Even clutch requested pressure JOLION_TRANSMISSION_EVEN_CLUTCH_REQUESTED_PRESSURE
- Service 22
DID 69BD - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Odd clutch actual pressure JOLION_TRANSMISSION_ODD_CLUTCH_ACTUAL_PRESSURE
- Service 22
DID 690B - Module
7E1 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -2000 to 63535 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Odd clutch requested pressure JOLION_TRANSMISSION_ODD_CLUTCH_REQUESTED_PRESSURE
- Service 22
DID 69BC - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Target gear JOLION_TRANSMISSION_TARGET_GEAR
- Service 22
DID 6926 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission fluid temperature JOLION_TFT
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D126 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission temperature, pan JOLION_TFT_PAN
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 6A0A - Module
7E1 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -55 to 65480 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Trips
Odometer, engine JOLION_ODO_ENG
Pelican can show this parameter as the odometer.
- Service 22
DID 121E - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission odometer JOLION_ODO_TRANS
Pelican can show this parameter as the odometer.
- Service 22
DID 6901 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Vehicle odometer JOLION_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 00A6 - Module
7E0 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.