INFINITI Q70

Parameters

The INFINITI Q70 has 887 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery current INFINITI_12V_CURR

  • Service 22DID 1183
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 128 A
Unit
A

In testing for 2011 to 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery current INFINITI_12V_CURR

  • Service 22DID 1183
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 128 A
Unit
A

In testing for 2011 to 2019.

12V battery supply voltage INFINITI_12V_BAT_SUP_V

  • Service 22DID CF00
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2011 to 2019.

12V battery voltage INFINITI_VPWR

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1103
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val12.5
Range
0 to 30 V
Unit
V

In testing for 2011 to 2019.

Absolute time since first ignition INFINITI_ABS_TIME_SINCE_FIRST

  • Service 22DID 9261
  • ModuleDADB → DAF1DB
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2011 to 2019.

Accelerator pedal position sensor 1, volts INFINITI_ACCEL_PEDAL_POS_SENS_1

  • Service 22DID 120D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Accelerator pedal position sensor 2, volts INFINITI_ACCEL_PEDAL_POS_SENS_2

  • Service 22DID 120E
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

ALTERNATOR set point VOLTAGE INFINITI_ALTERNATOR_SETPOINT_V

  • Service 21PID 69
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 V
Unit
V

In testing for 2011 to 2019.

Battery cell 01 INFINITI_BAT_CELL_01

  • Service 22DID CF1D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 02 INFINITI_BAT_CELL_02

  • Service 22DID CF1E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 03 INFINITI_BAT_CELL_03

  • Service 22DID CF1F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 04 INFINITI_BAT_CELL_04

  • Service 22DID CF20
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 05 INFINITI_BAT_CELL_05

  • Service 22DID CF21
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 06 INFINITI_BAT_CELL_06

  • Service 22DID CF22
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 07 INFINITI_BAT_CELL_07

  • Service 22DID CF23
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 08 INFINITI_BAT_CELL_08

  • Service 22DID CF24
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 09 INFINITI_BAT_CELL_09

  • Service 22DID CF25
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 10 INFINITI_BAT_CELL_10

  • Service 22DID CF26
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 11 INFINITI_BAT_CELL_11

  • Service 22DID CF27
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 12 INFINITI_BAT_CELL_12

  • Service 22DID CF28
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 13 INFINITI_BAT_CELL_13

  • Service 22DID CF29
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 14 INFINITI_BAT_CELL_14

  • Service 22DID CF2A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 15 INFINITI_BAT_CELL_15

  • Service 22DID CF2B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 16 INFINITI_BAT_CELL_16

  • Service 22DID CF2C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 17 INFINITI_BAT_CELL_17

  • Service 22DID CF2D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 18 INFINITI_BAT_CELL_18

  • Service 22DID CF2E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 19 INFINITI_BAT_CELL_19

  • Service 22DID CF2F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 20 INFINITI_BAT_CELL_20

  • Service 22DID CF30
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 21 INFINITI_BAT_CELL_21

  • Service 22DID CF31
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 22 INFINITI_BAT_CELL_22

  • Service 22DID CF32
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 23 INFINITI_BAT_CELL_23

  • Service 22DID CF33
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 24 INFINITI_BAT_CELL_24

  • Service 22DID CF34
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 25 INFINITI_BAT_CELL_25

  • Service 22DID CF35
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 26 INFINITI_BAT_CELL_26

  • Service 22DID CF36
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 27 INFINITI_BAT_CELL_27

  • Service 22DID CF37
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 28 INFINITI_BAT_CELL_28

  • Service 22DID CF38
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 29 INFINITI_BAT_CELL_29

  • Service 22DID CF39
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 30 INFINITI_BAT_CELL_30

  • Service 22DID CF3A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 31 INFINITI_BAT_CELL_31

  • Service 22DID CF3B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 32 INFINITI_BAT_CELL_32

  • Service 22DID CF3C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 33 INFINITI_BAT_CELL_33

  • Service 22DID CF3D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 34 INFINITI_BAT_CELL_34

  • Service 22DID CF3E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 35 INFINITI_BAT_CELL_35

  • Service 22DID CF3F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 36 INFINITI_BAT_CELL_36

  • Service 22DID CF40
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 37 INFINITI_BAT_CELL_37

  • Service 22DID CF41
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 38 INFINITI_BAT_CELL_38

  • Service 22DID CF42
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 39 INFINITI_BAT_CELL_39

  • Service 22DID CF43
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 40 INFINITI_BAT_CELL_40

  • Service 22DID CF44
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 41 INFINITI_BAT_CELL_41

  • Service 22DID CF45
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 42 INFINITI_BAT_CELL_42

  • Service 22DID CF46
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 43 INFINITI_BAT_CELL_43

  • Service 22DID CF47
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 44 INFINITI_BAT_CELL_44

  • Service 22DID CF48
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 45 INFINITI_BAT_CELL_45

  • Service 22DID CF49
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 46 INFINITI_BAT_CELL_46

  • Service 22DID CF4A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 47 INFINITI_BAT_CELL_47

  • Service 22DID CF4B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 48 INFINITI_BAT_CELL_48

  • Service 22DID CF4C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 49 INFINITI_BAT_CELL_49

  • Service 22DID CF4D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 50 INFINITI_BAT_CELL_50

  • Service 22DID CF4E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 51 INFINITI_BAT_CELL_51

  • Service 22DID CF4F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 52 INFINITI_BAT_CELL_52

  • Service 22DID CF50
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 53 INFINITI_BAT_CELL_53

  • Service 22DID CF51
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 54 INFINITI_BAT_CELL_54

  • Service 22DID CF52
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 55 INFINITI_BAT_CELL_55

  • Service 22DID CF53
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 56 INFINITI_BAT_CELL_56

  • Service 22DID CF54
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 57 INFINITI_BAT_CELL_57

  • Service 22DID CF55
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 58 INFINITI_BAT_CELL_58

  • Service 22DID CF56
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 59 INFINITI_BAT_CELL_59

  • Service 22DID CF57
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 60 INFINITI_BAT_CELL_60

  • Service 22DID CF58
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 61 INFINITI_BAT_CELL_61

  • Service 22DID CF59
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 62 INFINITI_BAT_CELL_62

  • Service 22DID CF5A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 63 INFINITI_BAT_CELL_63

  • Service 22DID CF5B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 64 INFINITI_BAT_CELL_64

  • Service 22DID CF5C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 65 INFINITI_BAT_CELL_65

  • Service 22DID CF5D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 66 INFINITI_BAT_CELL_66

  • Service 22DID CF5E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 67 INFINITI_BAT_CELL_67

  • Service 22DID CF5F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 68 INFINITI_BAT_CELL_68

  • Service 22DID CF60
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 69 INFINITI_BAT_CELL_69

  • Service 22DID CF61
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 70 INFINITI_BAT_CELL_70

  • Service 22DID CF62
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 71 INFINITI_BAT_CELL_71

  • Service 22DID CF63
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 72 INFINITI_BAT_CELL_72

  • Service 22DID CF64
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 73 INFINITI_BAT_CELL_73

  • Service 22DID CF65
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 74 INFINITI_BAT_CELL_74

  • Service 22DID CF66
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 75 INFINITI_BAT_CELL_75

  • Service 22DID CF67
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 76 INFINITI_BAT_CELL_76

  • Service 22DID CF68
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 77 INFINITI_BAT_CELL_77

  • Service 22DID CF69
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 78 INFINITI_BAT_CELL_78

  • Service 22DID CF6A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 79 INFINITI_BAT_CELL_79

  • Service 22DID CF6B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery cell 80 INFINITI_BAT_CELL_80

  • Service 22DID CF6C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Battery voltage INFINITI_BAT_V

  • Service 22DID 2005
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2011 to 2019.

Battery voltage, engine module INFINITI_VPWR_ECM

  • Service 22DID 1103
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.08
Range
0 to 20.4 V
Unit
V

In testing for 2011 to 2019.

Boost pressure sensor voltage INFINITI_BOOST_P_SENS_V

  • Service 22DID 20C6
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2011 to 2019.

Bus bar 1 flag INFINITI_BUSBAR_NO_1

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 1 voltage INFINITI_BUSBAR_V_NO_1

  • Service 22DID 9221
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 2 flag INFINITI_BUSBAR_NO_2

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 2 voltage INFINITI_BUSBAR_V_NO_2

  • Service 22DID 9222
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 3 flag INFINITI_BUSBAR_NO_3

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 3 voltage INFINITI_BUSBAR_V_NO_3

  • Service 22DID 9223
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 4 flag INFINITI_BUSBAR_NO_4

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 4 voltage INFINITI_BUSBAR_V_NO_4

  • Service 22DID 9224
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 5 flag INFINITI_BUSBAR_NO_5

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 5 voltage INFINITI_BUSBAR_V_NO_5

  • Service 22DID 9225
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 6 flag INFINITI_BUSBAR_NO_6

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 6 voltage INFINITI_BUSBAR_V_NO_6

  • Service 22DID 9226
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 7 flag INFINITI_BUSBAR_NO_7

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 7 voltage INFINITI_BUSBAR_V_NO_7

  • Service 22DID 9227
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 8 flag INFINITI_BUSBAR_NO_8

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 8 voltage INFINITI_BUSBAR_V_NO_8

  • Service 22DID 9228
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2011 to 2019.

Bus bar 9 flag INFINITI_BUSBAR_NO_9

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 10 flag INFINITI_BUSBAR_NO_10

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 11 flag INFINITI_BUSBAR_NO_11

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Bus bar 12 flag INFINITI_BUSBAR_NO_12

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 1 flag INFINITI_CELL_NUMBER_1

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 1 state of health flag INFINITI_SOH_CELL_1

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 1 voltage INFINITI_HVBAT_CELL_1_V

  • Service 22DID 9021
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 2 flag INFINITI_CELL_NUMBER_2

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 2 state of health flag INFINITI_SOH_CELL_2

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 2 voltage INFINITI_HVBAT_CELL_2_V

  • Service 22DID 9022
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 3 flag INFINITI_CELL_NUMBER_3

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 3 state of health flag INFINITI_SOH_CELL_3

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 3 voltage INFINITI_HVBAT_CELL_3_V

  • Service 22DID 9023
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 4 flag INFINITI_CELL_NUMBER_4

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 4 state of health flag INFINITI_SOH_CELL_4

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 4 voltage INFINITI_HVBAT_CELL_4_V

  • Service 22DID 9024
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 5 flag INFINITI_CELL_NUMBER_5

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 5 state of health flag INFINITI_SOH_CELL_5

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 5 voltage INFINITI_HVBAT_CELL_5_V

  • Service 22DID 9025
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 6 flag INFINITI_CELL_NUMBER_6

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 6 state of health flag INFINITI_SOH_CELL_6

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 6 voltage INFINITI_HVBAT_CELL_6_V

  • Service 22DID 9026
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 7 flag INFINITI_CELL_NUMBER_7

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 7 state of health flag INFINITI_SOH_CELL_7

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 7 voltage INFINITI_HVBAT_CELL_7_V

  • Service 22DID 9027
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 8 flag INFINITI_CELL_NUMBER_8

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 8 state of health flag INFINITI_SOH_CELL_8

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 8 voltage INFINITI_HVBAT_CELL_8_V

  • Service 22DID 9028
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 9 flag INFINITI_CELL_NUMBER_9

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 9 state of health flag INFINITI_SOH_CELL_9

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 9 voltage INFINITI_HVBAT_CELL_9_V

  • Service 22DID 9029
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 10 flag INFINITI_CELL_NUMBER_10

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 10 state of health flag INFINITI_SOH_CELL_10

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 10 voltage INFINITI_HVBAT_CELL_10_V

  • Service 22DID 902A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 11 flag INFINITI_CELL_NUMBER_11

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 11 state of health flag INFINITI_SOH_CELL_11

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 11 voltage INFINITI_HVBAT_CELL_11_V

  • Service 22DID 902B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 12 flag INFINITI_CELL_NUMBER_12

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 12 state of health flag INFINITI_SOH_CELL_12

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 12 voltage INFINITI_HVBAT_CELL_12_V

  • Service 22DID 902C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 13 flag INFINITI_CELL_NUMBER_13

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 13 state of health flag INFINITI_SOH_CELL_13

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 13 voltage INFINITI_HVBAT_CELL_13_V

  • Service 22DID 902D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 14 flag INFINITI_CELL_NUMBER_14

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 14 state of health flag INFINITI_SOH_CELL_14

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 14 voltage INFINITI_HVBAT_CELL_14_V

  • Service 22DID 902E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 15 flag INFINITI_CELL_NUMBER_15

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 15 state of health flag INFINITI_SOH_CELL_15

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 15 voltage INFINITI_HVBAT_CELL_15_V

  • Service 22DID 902F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 16 flag INFINITI_CELL_NUMBER_16

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 16 state of health flag INFINITI_SOH_CELL_16

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 16 voltage INFINITI_HVBAT_CELL_16_V

  • Service 22DID 9030
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 17 flag INFINITI_CELL_NUMBER_17

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 17 state of health flag INFINITI_SOH_CELL_17

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 17 voltage INFINITI_HVBAT_CELL_17_V

  • Service 22DID 9031
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 18 flag INFINITI_CELL_NUMBER_18

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 18 state of health flag INFINITI_SOH_CELL_18

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 18 voltage INFINITI_HVBAT_CELL_18_V

  • Service 22DID 9032
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 19 flag INFINITI_CELL_NUMBER_19

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 19 state of health flag INFINITI_SOH_CELL_19

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 19 voltage INFINITI_HVBAT_CELL_19_V

  • Service 22DID 9033
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 20 flag INFINITI_CELL_NUMBER_20

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 20 state of health flag INFINITI_SOH_CELL_20

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 20 voltage INFINITI_HVBAT_CELL_20_V

  • Service 22DID 9034
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 21 flag INFINITI_CELL_NUMBER_21

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 21 state of health flag INFINITI_SOH_CELL_21

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 21 voltage INFINITI_HVBAT_CELL_21_V

  • Service 22DID 9035
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 22 flag INFINITI_CELL_NUMBER_22

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 22 state of health flag INFINITI_SOH_CELL_22

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 22 voltage INFINITI_HVBAT_CELL_22_V

  • Service 22DID 9036
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 23 flag INFINITI_CELL_NUMBER_23

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 23 state of health flag INFINITI_SOH_CELL_23

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 23 voltage INFINITI_HVBAT_CELL_23_V

  • Service 22DID 9037
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 24 flag INFINITI_CELL_NUMBER_24

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 24 state of health flag INFINITI_SOH_CELL_24

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 24 voltage INFINITI_HVBAT_CELL_24_V

  • Service 22DID 9038
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 25 flag INFINITI_CELL_NUMBER_25

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 25 state of health flag INFINITI_SOH_CELL_25

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 25 voltage INFINITI_HVBAT_CELL_25_V

  • Service 22DID 9039
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 26 flag INFINITI_CELL_NUMBER_26

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 26 state of health flag INFINITI_SOH_CELL_26

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 26 voltage INFINITI_HVBAT_CELL_26_V

  • Service 22DID 903A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 27 flag INFINITI_CELL_NUMBER_27

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 27 state of health flag INFINITI_SOH_CELL_27

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 27 voltage INFINITI_HVBAT_CELL_27_V

  • Service 22DID 903B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 28 flag INFINITI_CELL_NUMBER_28

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 28 state of health flag INFINITI_SOH_CELL_28

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 28 voltage INFINITI_HVBAT_CELL_28_V

  • Service 22DID 903C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 29 flag INFINITI_CELL_NUMBER_29

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 29 state of health flag INFINITI_SOH_CELL_29

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 29 voltage INFINITI_HVBAT_CELL_29_V

  • Service 22DID 903D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 30 flag INFINITI_CELL_NUMBER_30

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 30 state of health flag INFINITI_SOH_CELL_30

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 30 voltage INFINITI_HVBAT_CELL_30_V

  • Service 22DID 903E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 31 flag INFINITI_CELL_NUMBER_31

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 31 state of health flag INFINITI_SOH_CELL_31

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 31 voltage INFINITI_HVBAT_CELL_31_V

  • Service 22DID 903F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 32 flag INFINITI_CELL_NUMBER_32

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 32 state of health flag INFINITI_SOH_CELL_32

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 32 voltage INFINITI_HVBAT_CELL_32_V

  • Service 22DID 9041
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 33 flag INFINITI_CELL_NUMBER_33

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 33 state of health flag INFINITI_SOH_CELL_33

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 33 voltage INFINITI_HVBAT_CELL_33_V

  • Service 22DID 9042
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 34 flag INFINITI_CELL_NUMBER_34

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 34 state of health flag INFINITI_SOH_CELL_34

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 34 voltage INFINITI_HVBAT_CELL_34_V

  • Service 22DID 9043
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 35 flag INFINITI_CELL_NUMBER_35

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 35 state of health flag INFINITI_SOH_CELL_35

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 35 voltage INFINITI_HVBAT_CELL_35_V

  • Service 22DID 9044
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 36 flag INFINITI_CELL_NUMBER_36

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 36 state of health flag INFINITI_SOH_CELL_36

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 36 voltage INFINITI_HVBAT_CELL_36_V

  • Service 22DID 9045
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 37 flag INFINITI_CELL_NUMBER_37

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 37 state of health flag INFINITI_SOH_CELL_37

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 37 voltage INFINITI_HVBAT_CELL_37_V

  • Service 22DID 9046
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 38 flag INFINITI_CELL_NUMBER_38

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 38 state of health flag INFINITI_SOH_CELL_38

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 38 voltage INFINITI_HVBAT_CELL_38_V

  • Service 22DID 9047
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 39 flag INFINITI_CELL_NUMBER_39

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 39 state of health flag INFINITI_SOH_CELL_39

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 39 voltage INFINITI_HVBAT_CELL_39_V

  • Service 22DID 9048
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 40 flag INFINITI_CELL_NUMBER_40

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 40 state of health flag INFINITI_SOH_CELL_40

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 40 voltage INFINITI_HVBAT_CELL_40_V

  • Service 22DID 9049
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 41 flag INFINITI_CELL_NUMBER_41

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 41 state of health flag INFINITI_SOH_CELL_41

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 41 voltage INFINITI_HVBAT_CELL_41_V

  • Service 22DID 904A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 42 flag INFINITI_CELL_NUMBER_42

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 42 state of health flag INFINITI_SOH_CELL_42

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 42 voltage INFINITI_HVBAT_CELL_42_V

  • Service 22DID 904B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 43 flag INFINITI_CELL_NUMBER_43

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 43 state of health flag INFINITI_SOH_CELL_43

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 43 voltage INFINITI_HVBAT_CELL_43_V

  • Service 22DID 904C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 44 flag INFINITI_CELL_NUMBER_44

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 44 state of health flag INFINITI_SOH_CELL_44

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 44 voltage INFINITI_HVBAT_CELL_44_V

  • Service 22DID 904D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 45 flag INFINITI_CELL_NUMBER_45

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 45 state of health flag INFINITI_SOH_CELL_45

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 45 voltage INFINITI_HVBAT_CELL_45_V

  • Service 22DID 904E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 46 flag INFINITI_CELL_NUMBER_46

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 46 state of health flag INFINITI_SOH_CELL_46

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 46 voltage INFINITI_HVBAT_CELL_46_V

  • Service 22DID 904F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 47 flag INFINITI_CELL_NUMBER_47

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 47 state of health flag INFINITI_SOH_CELL_47

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 47 voltage INFINITI_HVBAT_CELL_47_V

  • Service 22DID 9050
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 48 flag INFINITI_CELL_NUMBER_48

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 48 state of health flag INFINITI_SOH_CELL_48

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 48 voltage INFINITI_HVBAT_CELL_48_V

  • Service 22DID 9051
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 49 flag INFINITI_CELL_NUMBER_49

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 49 state of health flag INFINITI_SOH_CELL_49

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 49 voltage INFINITI_HVBAT_CELL_49_V

  • Service 22DID 9052
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 50 flag INFINITI_CELL_NUMBER_50

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 50 state of health flag INFINITI_SOH_CELL_50

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 50 voltage INFINITI_HVBAT_CELL_50_V

  • Service 22DID 9053
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 51 flag INFINITI_CELL_NUMBER_51

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 51 state of health flag INFINITI_SOH_CELL_51

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 51 voltage INFINITI_HVBAT_CELL_51_V

  • Service 22DID 9054
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 52 flag INFINITI_CELL_NUMBER_52

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 52 state of health flag INFINITI_SOH_CELL_52

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 52 voltage INFINITI_HVBAT_CELL_52_V

  • Service 22DID 9055
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 53 flag INFINITI_CELL_NUMBER_53

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 53 state of health flag INFINITI_SOH_CELL_53

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 53 voltage INFINITI_HVBAT_CELL_53_V

  • Service 22DID 9056
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 54 flag INFINITI_CELL_NUMBER_54

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 54 state of health flag INFINITI_SOH_CELL_54

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 54 voltage INFINITI_HVBAT_CELL_54_V

  • Service 22DID 9057
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 55 flag INFINITI_CELL_NUMBER_55

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 55 state of health flag INFINITI_SOH_CELL_55

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 55 voltage INFINITI_HVBAT_CELL_55_V

  • Service 22DID 9058
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 56 flag INFINITI_CELL_NUMBER_56

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 56 state of health flag INFINITI_SOH_CELL_56

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 56 voltage INFINITI_HVBAT_CELL_56_V

  • Service 22DID 9059
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 57 flag INFINITI_CELL_NUMBER_57

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 57 state of health flag INFINITI_SOH_CELL_57

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 57 voltage INFINITI_HVBAT_CELL_57_V

  • Service 22DID 905A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 58 flag INFINITI_CELL_NUMBER_58

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 58 state of health flag INFINITI_SOH_CELL_58

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 58 voltage INFINITI_HVBAT_CELL_58_V

  • Service 22DID 905B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 59 flag INFINITI_CELL_NUMBER_59

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 59 state of health flag INFINITI_SOH_CELL_59

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 59 voltage INFINITI_HVBAT_CELL_59_V

  • Service 22DID 905C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 60 flag INFINITI_CELL_NUMBER_60

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 60 state of health flag INFINITI_SOH_CELL_60

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 60 voltage INFINITI_HVBAT_CELL_60_V

  • Service 22DID 905D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 61 flag INFINITI_CELL_NUMBER_61

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 61 state of health flag INFINITI_SOH_CELL_61

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 61 voltage INFINITI_HVBAT_CELL_61_V

  • Service 22DID 905E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 62 flag INFINITI_CELL_NUMBER_62

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 62 state of health flag INFINITI_SOH_CELL_62

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 62 voltage INFINITI_HVBAT_CELL_62_V

  • Service 22DID 905F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 63 flag INFINITI_CELL_NUMBER_63

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 63 state of health flag INFINITI_SOH_CELL_63

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 63 voltage INFINITI_HVBAT_CELL_63_V

  • Service 22DID 9061
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 64 flag INFINITI_CELL_NUMBER_64

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 64 state of health flag INFINITI_SOH_CELL_64

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 64 voltage INFINITI_HVBAT_CELL_64_V

  • Service 22DID 9062
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 65 flag INFINITI_CELL_NUMBER_65

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 65 state of health flag INFINITI_SOH_CELL_65

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 65 voltage INFINITI_HVBAT_CELL_65_V

  • Service 22DID 9063
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 66 flag INFINITI_CELL_NUMBER_66

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 66 state of health flag INFINITI_SOH_CELL_66

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 66 voltage INFINITI_HVBAT_CELL_66_V

  • Service 22DID 9064
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 67 flag INFINITI_CELL_NUMBER_67

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 67 state of health flag INFINITI_SOH_CELL_67

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 67 voltage INFINITI_HVBAT_CELL_67_V

  • Service 22DID 9065
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 68 flag INFINITI_CELL_NUMBER_68

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 68 state of health flag INFINITI_SOH_CELL_68

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 68 voltage INFINITI_HVBAT_CELL_68_V

  • Service 22DID 9066
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 69 flag INFINITI_CELL_NUMBER_69

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 69 state of health flag INFINITI_SOH_CELL_69

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 69 voltage INFINITI_HVBAT_CELL_69_V

  • Service 22DID 9067
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 70 flag INFINITI_CELL_NUMBER_70

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 70 state of health flag INFINITI_SOH_CELL_70

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 70 voltage INFINITI_HVBAT_CELL_70_V

  • Service 22DID 9068
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 71 flag INFINITI_CELL_NUMBER_71

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 71 state of health flag INFINITI_SOH_CELL_71

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 71 voltage INFINITI_HVBAT_CELL_71_V

  • Service 22DID 9069
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 72 flag INFINITI_CELL_NUMBER_72

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 72 state of health flag INFINITI_SOH_CELL_72

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 72 voltage INFINITI_HVBAT_CELL_72_V

  • Service 22DID 906A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 73 flag INFINITI_CELL_NUMBER_73

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 73 state of health flag INFINITI_SOH_CELL_73

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 73 voltage INFINITI_HVBAT_CELL_73_V

  • Service 22DID 906B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 74 flag INFINITI_CELL_NUMBER_74

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 74 state of health flag INFINITI_SOH_CELL_74

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 74 voltage INFINITI_HVBAT_CELL_74_V

  • Service 22DID 906C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 75 flag INFINITI_CELL_NUMBER_75

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 75 state of health flag INFINITI_SOH_CELL_75

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 75 voltage INFINITI_HVBAT_CELL_75_V

  • Service 22DID 906D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 76 flag INFINITI_CELL_NUMBER_76

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 76 state of health flag INFINITI_SOH_CELL_76

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 76 voltage INFINITI_HVBAT_CELL_76_V

  • Service 22DID 906E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 77 flag INFINITI_CELL_NUMBER_77

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 77 state of health flag INFINITI_SOH_CELL_77

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 77 voltage INFINITI_HVBAT_CELL_77_V

  • Service 22DID 906F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 78 flag INFINITI_CELL_NUMBER_78

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 78 state of health flag INFINITI_SOH_CELL_78

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 78 voltage INFINITI_HVBAT_CELL_78_V

  • Service 22DID 9070
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 79 state of health flag INFINITI_SOH_CELL_79

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 79 voltage INFINITI_HVBAT_CELL_79_V

  • Service 22DID 9071
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 80 flag INFINITI_CELL_NUMBER_80

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 80 state of health flag INFINITI_SOH_CELL_80

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 80 voltage INFINITI_HVBAT_CELL_80_V

  • Service 22DID 9072
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 81 flag INFINITI_CELL_NUMBER_81

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 81 state of health flag INFINITI_SOH_CELL_81

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 81 voltage INFINITI_HVBAT_CELL_81_V

  • Service 22DID 9073
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 82 flag INFINITI_CELL_NUMBER_82

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 82 state of health flag INFINITI_SOH_CELL_82

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 82 voltage INFINITI_HVBAT_CELL_82_V

  • Service 22DID 9074
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 83 flag INFINITI_CELL_NUMBER_83

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 83 state of health flag INFINITI_SOH_CELL_83

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 83 voltage INFINITI_HVBAT_CELL_83_V

  • Service 22DID 9075
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 84 flag INFINITI_CELL_NUMBER_84

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 84 state of health flag INFINITI_SOH_CELL_84

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 84 voltage INFINITI_HVBAT_CELL_84_V

  • Service 22DID 9076
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 85 flag INFINITI_CELL_NUMBER_85

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 85 state of health flag INFINITI_SOH_CELL_85

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 85 voltage INFINITI_HVBAT_CELL_85_V

  • Service 22DID 9077
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 86 flag INFINITI_CELL_NUMBER_86

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 86 state of health flag INFINITI_SOH_CELL_86

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 86 voltage INFINITI_HVBAT_CELL_86_V

  • Service 22DID 9078
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 87 flag INFINITI_CELL_NUMBER_87

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 87 state of health flag INFINITI_SOH_CELL_87

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 87 voltage INFINITI_HVBAT_CELL_87_V

  • Service 22DID 9079
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 88 flag INFINITI_CELL_NUMBER_88

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 88 state of health flag INFINITI_SOH_CELL_88

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 88 voltage INFINITI_HVBAT_CELL_88_V

  • Service 22DID 907A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 89 flag INFINITI_CELL_NUMBER_89

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 89 state of health flag INFINITI_SOH_CELL_89

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 89 voltage INFINITI_HVBAT_CELL_89_V

  • Service 22DID 907B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 90 flag INFINITI_CELL_NUMBER_90

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 90 state of health flag INFINITI_SOH_CELL_90

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 90 voltage INFINITI_HVBAT_CELL_90_V

  • Service 22DID 907C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 91 flag INFINITI_CELL_NUMBER_91

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 91 state of health flag INFINITI_SOH_CELL_91

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 91 voltage INFINITI_HVBAT_CELL_91_V

  • Service 22DID 907D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 92 flag INFINITI_CELL_NUMBER_92

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 92 state of health flag INFINITI_SOH_CELL_92

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 92 voltage INFINITI_HVBAT_CELL_92_V

  • Service 22DID 907E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 93 flag INFINITI_CELL_NUMBER_93

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 93 state of health flag INFINITI_SOH_CELL_93

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 93 voltage INFINITI_HVBAT_CELL_93_V

  • Service 22DID 907F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 94 flag INFINITI_CELL_NUMBER_94

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 94 state of health flag INFINITI_SOH_CELL_94

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 94 voltage INFINITI_HVBAT_CELL_94_V

  • Service 22DID 9081
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 95 flag INFINITI_CELL_NUMBER_95

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 95 state of health flag INFINITI_SOH_CELL_95

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 95 voltage INFINITI_HVBAT_CELL_95_V

  • Service 22DID 9082
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell 96 flag INFINITI_CELL_NUMBER_96

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 96 state of health flag INFINITI_SOH_CELL_96

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cell 96 voltage INFINITI_HVBAT_CELL_96_V

  • Service 22DID 9083
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cell with the highest voltage INFINITI_CELL_HIGHEST_V

  • Service 22DID 9008
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2011 to 2019.

Cell with the lowest voltage INFINITI_CELL_LOWEST_V

  • Service 22DID 900A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2011 to 2019.

Cells overvoltage INFINITI_CELLS_OVERVOLAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Cells undervoltage INFINITI_CELLS_UNDERVOLTAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Charging mode INFINITI_CHARGE_MODE

Pelican can show this parameter as the charging state.

  • Service 22DID 114E
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_CHARGINGNot charging
1CHARGING_L1L1 charging (100-120V)
2CHARGING_L2L2 charging (200-240V)
3CHARGING_L3L3 quick charging

In testing for 2011 to 2019.

Charging power INFINITI_CHRG_PWR

Power entering the high voltage battery while charging.

  • Service 22DID 1236
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500 W
Unit
W

In testing for 2011 to 2019.

Computer power supply INFINITI_COMPUTER_POWER_SUP

  • Service 22DID 9011
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Cumulative energy when discharging INFINITI_CUM_ENERGY

  • Service 22DID 9245
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 kWh
Unit
kWh

In testing for 2011 to 2019.

DC battery capacity INFINITI_DC_BAT_CAP

  • Service 22DID 91C8
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777 kWh
Unit
kWh

In testing for 2011 to 2019.

DC battery current INFINITI_DC_BAT_CURRENT

  • Service 22DID 21CC
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-14+500
Range
-15883 to 500 A
Unit
A

In testing for 2011 to 2019.

DC battery state of charge INFINITI_DC_BAT_ST_CHG

  • Service 22DID 9002
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2011 to 2019.

DC battery state of health INFINITI_DC_BAT_ST_HEALTH

  • Service 22DID 9003
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2011 to 2019.

DC battery voltage INFINITI_DC_BAT_V

  • Service 22DID 20FE
  • ModuleDADA → DAF1DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2011 to 2019.

EVAP pressure sensor voltage INFINITI_EVAP_P_SENS_V

  • Service 22DID 1115
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2011 to 2019.

Exhaust gas recirculation temperature sensor voltage INFINITI_EGR_T_SENS_V

  • Service 22DID 1105
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2011 to 2019.

Fan unit INFINITI_FAN_UNIT

  • Service 22DID 91EF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Fan unit feed INFINITI_FAN_UNIT_FEED

  • Service 22DID 925A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 Hz
Unit
Hz

In testing for 2011 to 2019.

Fault finding version INFINITI_FAULT_FINDING

  • Service 22DID F1A0
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Fuel pressure sensor voltage INFINITI_FUEL_P_SENS_V

  • Service 22DID 120C
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×413107
Range
0 to 20 V
Unit
V

In testing for 2011 to 2019.

Fuel rail temperature sensor voltage INFINITI_FUEL_RAIL_T_SENS_V

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2011 to 2019.

Fuel tank temperature sensor voltage INFINITI_FUEL_TANK_T_SENS_V

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2011 to 2019.

High voltage battery available charge display INFINITI_HVBAT_AVAILABLE_CHG

  • Service 22DID 114B
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

High voltage battery capacity INFINITI_HVBAT_CAP

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 280 to 303 of the reply, 24 bits.

Formula
val10000
Range
0 to 1000 Ah
Unit
Ah

In testing for 2011 to 2019.

High voltage battery capacity INFINITI_HVBAT_CAP_PRE18

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 264 to 287 of the reply, 24 bits.

Formula
val10000
Range
0 to 1000 Ah
Unit
Ah

In testing for 2011 to 2019.

High voltage battery charge INFINITI_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 248 to 271 of the reply, 24 bits.

Formula
val8190−17
Range
0 to 100 %
Unit
%

In testing for 2011 to 2019.

High voltage battery charge INFINITI_HVBAT_SOC_PRE18

Pelican can show this parameter as the state of charge.

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 232 to 255 of the reply, 24 bits.

Formula
val10000
Range
0 to 100 %
Unit
%

In testing for 2011 to 2019.

High voltage battery current INFINITI_HVBAT_CURRENT

  • Service 22DID CF08
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676 A
Unit
A

In testing for 2011 to 2019.

High voltage battery current, high INFINITI_HVBAT_CURRENT_HIGH

  • Service 22DID CF0A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676 A
Unit
A

In testing for 2011 to 2019.

High voltage battery current, low INFINITI_HVBAT_CURRENT_LOW

  • Service 22DID CF09
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676 A
Unit
A

In testing for 2011 to 2019.

High voltage battery health INFINITI_HVBAT_SOH

When the battery is new, its health should be ~100%.

Pelican can show this parameter as the state of health.

  • Service 21PID 61
  • Module79B → 7BB
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2011 to 2019.

High voltage battery intake air temperature INFINITI_HVBAT_IAT

  • Service 22DID CF12
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2011 to 2019.

High voltage battery temperature sensor 1 INFINITI_HVBAT_T_SENS_1

  • Service 22DID CF0D
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2011 to 2019.

High voltage battery temperature sensor 2 INFINITI_HVBAT_T_SENS_2

  • Service 22DID CF0E
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2011 to 2019.

High voltage battery temperature sensor 3 INFINITI_HVBAT_T_SENS_3

  • Service 22DID CF0F
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2011 to 2019.

High voltage battery temperature sensor 4 INFINITI_HVBAT_T_SENS_4

  • Service 22DID CF11
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2011 to 2019.

High voltage battery voltage INFINITI_HVBAT_V_V2

  • Service 22DID CF05
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2011 to 2019.

High voltage battery voltage INFINITI_HVBAT_VOLT

Pelican can show this parameter as the traction battery voltage.

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2011 to 2019.

High voltage battery voltage INFINITI_HVBAT_VOLT_PRE18

Pelican can show this parameter as the traction battery voltage.

  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2011 to 2019.

High voltage state of charge INFINITI_HIGH_V_ST_CHG

  • Service 22DID CF04
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2011 to 2019.

Highest cell voltage level INFINITI_HIGHEST_CELL_V_LEVEL

  • Service 22DID 9007
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

HV battery current INFINITI_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1248
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 A
Unit
A

In testing for 2011 to 2019.

HV battery pack 1 temperature INFINITI_HVBAT_PACK_1_T

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2019.

HV battery pack 2 temperature INFINITI_HVBAT_PACK_2_T

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2019.

HV battery pack 4 temperature INFINITI_HVBAT_PACK_4_T

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2019.

HV battery pack 5 temperature INFINITI_HVBAT_PACK_5_T

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2019.

HV battery pack voltage INFINITI_HVBAT_PACK_V

Pelican can show this parameter as the traction battery voltage.

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2011 to 2019.

HV bus voltage INFINITI_HVBAT_BUS_V

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2011 to 2019.

L1/L2 charge port plug state INFINITI_CHARGE_PLUG

Pelican can show this parameter as the plug state.

  • Service 22DID 1234
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNPLUGGEDNot plugged in
1PLUGGED_PARTIALPartially plugged in
2PLUGGEDPlugged in

In testing for 2011 to 2019.

Lowest cell voltage level INFINITI_LOWEST_CELL_V_LEVEL

  • Service 22DID 9009
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2011 to 2019.

Manifold pressure sensor voltage INFINITI_MANIFOLD_P_SENS_V

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2011 to 2019.

Mass air flow volts INFINITI_MAF_VOLTS

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Max cell voltage INFINITI_MAX_CELL_V_V2

  • Service 22DID CF06
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Maximum cell voltage INFINITI_MAX_CELL_V

  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 4.5 V
Unit
V

In testing for 2011 to 2019.

Min cell voltage INFINITI_MIN_CELL_V_V2

  • Service 22DID CF07
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2011 to 2019.

Minimum cell voltage INFINITI_MIN_CELL_V

  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 4.5 V
Unit
V

In testing for 2011 to 2019.

Module 1 temperature INFINITI_MODULE_T_NUMBER_1

  • Service 22DID 9131
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 1 temperature sensor flag INFINITI_T_SENS_MODULE_N_1

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 2 temperature INFINITI_MODULE_T_NUMBER_2

  • Service 22DID 9132
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 2 temperature sensor flag INFINITI_T_SENS_MODULE_N_2

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 3 temperature INFINITI_MODULE_T_NUMBER_3

  • Service 22DID 9133
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 3 temperature sensor flag INFINITI_T_SENS_MODULE_N_3

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 4 temperature INFINITI_MODULE_T_NUMBER_4

  • Service 22DID 9134
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 4 temperature sensor flag INFINITI_T_SENS_MODULE_N_4

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 5 temperature INFINITI_MODULE_T_NUMBER_5

  • Service 22DID 9135
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 5 temperature sensor flag INFINITI_T_SENS_MODULE_N_5

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 6 temperature INFINITI_MODULE_T_NUMBER_6

  • Service 22DID 9136
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 6 temperature sensor flag INFINITI_T_SENS_MODULE_N_6

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 7 temperature INFINITI_MODULE_T_NUMBER_7

  • Service 22DID 9137
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 7 temperature sensor flag INFINITI_T_SENS_MODULE_N_7

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 8 temperature INFINITI_MODULE_T_NUMBER_8

  • Service 22DID 9138
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 8 temperature sensor flag INFINITI_T_SENS_MODULE_N_8

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 9 temperature INFINITI_MODULE_T_NUMBER_9

  • Service 22DID 9139
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 9 temperature sensor flag INFINITI_T_SENS_MODULE_N_9

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 10 temperature INFINITI_MODULE_T_NUMBER_10

  • Service 22DID 913A
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 10 temperature sensor flag INFINITI_T_SENS_MODULE_N_10

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 11 temperature INFINITI_MODULE_T_NUMBER_11

  • Service 22DID 913B
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 11 temperature sensor flag INFINITI_T_SENS_MODULE_N_11

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module 12 temperature INFINITI_MODULE_T_NUMBER_12

  • Service 22DID 913C
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Module 12 temperature sensor flag INFINITI_T_SENS_MODULE_N_12

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Module with the minimum temperature INFINITI_MODULE_MIN_T

  • Service 22DID 9242
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Motor-driven fan unit request INFINITI_MOTOR_DRIVEN_FAN

  • Service 22DID 91C9
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2011 to 2019.

Open circuit voltage INFINITI_OPEN_CIRCUIT_V

  • Service 22DID 9005
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2011 to 2019.

Refrigerant fluid sensor voltage INFINITI_REFRIGERANT_FLUID_V

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Roll-over sensor voltage INFINITI_ROLL_OVER_SENS_V

  • Service 22DID 121F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Rough turbocharger pressure INFINITI_ROUGH_TURBOCHARGER_P

  • Service 22DID F40B
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2011 to 2019.

Secondary battery management board 1 INFINITI_SECONDARY_BMS_NO_1

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 2 INFINITI_SECONDARY_BMS_NO_2

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 3 INFINITI_SECONDARY_BMS_NO_3

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 4 INFINITI_SECONDARY_BMS_NO_4

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 5 INFINITI_SECONDARY_BMS_NO_5

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 6 INFINITI_SECONDARY_BMS_NO_6

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 7 INFINITI_SECONDARY_BMS_NO_7

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 8 INFINITI_SECONDARY_BMS_NO_8

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 9 INFINITI_SECONDARY_BMS_NO_9

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 10 INFINITI_SECONDARY_BMS_NO_10

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 11 INFINITI_SECONDARY_BMS_NO_11

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Secondary battery management board 12 INFINITI_SECONDARY_BMS_NO_12

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

State of charge, as the dash shows it INFINITI_SOC_DASH

Pelican can show this parameter as the state of charge.

  • Service 22DID 0E2D
  • Module743 → 763
  • Every30 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2011 to 2019.

Throttle position sensor 1, volts INFINITI_THROTTLE_POS_SENS_1

  • Service 22DID 120F
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Throttle position sensor 2, volts INFINITI_THROTTLE_POS_SENS_2

  • Service 22DID 1210
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Traction battery compartment temperature INFINITI_TRACTION_BAT_T

  • Service 22DID 9012
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Traction battery current INFINITI_TRACTION_BAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 9284
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×-11000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2011 to 2019.

Traction battery input water temperature INFINITI_TRACTION_BAT_INPUT_T

  • Service 22DID 91CD
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Traction battery interlock INFINITI_TRACTION_BAT_INTERLOCK

  • Service 22DID 91F7
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Traction battery maximum temperature INFINITI_TRACTION_BAT_MAX_T

  • Service 22DID 9014
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Traction battery minimum temperature INFINITI_TRACTION_BAT_MIN_T

  • Service 22DID 9013
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2011 to 2019.

Traction battery overcurrent INFINITI_TRACTION_BAT_OVERCURRENT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Traction battery overheating INFINITI_TRACTION_BAT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

Traction battery service plug interlock INFINITI_TRACTION_BAT_SERVICE

  • Service 22DID 91F6
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Traction battery state of charge INFINITI_TRACTION_BAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 9001
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−3
Range
-3 to 652 %
Unit
%

In testing for 2011 to 2019.

Traction battery total mileage INFINITI_TRACTION_BAT_TOT

  • Service 22DID 91CF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val32+67108864
Range
0 to 134217727 km
Unit
km

In testing for 2011 to 2019.

Traction battery voltage INFINITI_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 9006
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
0 to 1000 V
Unit
V

In testing for 2011 to 2019.

Upstream oxygen sensor voltage INFINITI_UP_OXYGEN_SENS_V

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Cells

HV battery cell 1 voltage INFINITI_HVBAT_CELL_1_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 2 voltage INFINITI_HVBAT_CELL_2_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 3 voltage INFINITI_HVBAT_CELL_3_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 4 voltage INFINITI_HVBAT_CELL_4_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 5 voltage INFINITI_HVBAT_CELL_5_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 6 voltage INFINITI_HVBAT_CELL_6_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 7 voltage INFINITI_HVBAT_CELL_7_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 8 voltage INFINITI_HVBAT_CELL_8_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 9 voltage INFINITI_HVBAT_CELL_9_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 10 voltage INFINITI_HVBAT_CELL_10_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 11 voltage INFINITI_HVBAT_CELL_11_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 12 voltage INFINITI_HVBAT_CELL_12_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 13 voltage INFINITI_HVBAT_CELL_13_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 14 voltage INFINITI_HVBAT_CELL_14_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 15 voltage INFINITI_HVBAT_CELL_15_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 16 voltage INFINITI_HVBAT_CELL_16_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 17 voltage INFINITI_HVBAT_CELL_17_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 18 voltage INFINITI_HVBAT_CELL_18_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 19 voltage INFINITI_HVBAT_CELL_19_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 20 voltage INFINITI_HVBAT_CELL_20_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 21 voltage INFINITI_HVBAT_CELL_21_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 22 voltage INFINITI_HVBAT_CELL_22_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 23 voltage INFINITI_HVBAT_CELL_23_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 24 voltage INFINITI_HVBAT_CELL_24_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 25 voltage INFINITI_HVBAT_CELL_25_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 26 voltage INFINITI_HVBAT_CELL_26_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 27 voltage INFINITI_HVBAT_CELL_27_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 28 voltage INFINITI_HVBAT_CELL_28_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 29 voltage INFINITI_HVBAT_CELL_29_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 30 voltage INFINITI_HVBAT_CELL_30_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 31 voltage INFINITI_HVBAT_CELL_31_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 32 voltage INFINITI_HVBAT_CELL_32_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 33 voltage INFINITI_HVBAT_CELL_33_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 34 voltage INFINITI_HVBAT_CELL_34_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 35 voltage INFINITI_HVBAT_CELL_35_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 36 voltage INFINITI_HVBAT_CELL_36_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 37 voltage INFINITI_HVBAT_CELL_37_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 38 voltage INFINITI_HVBAT_CELL_38_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 39 voltage INFINITI_HVBAT_CELL_39_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 40 voltage INFINITI_HVBAT_CELL_40_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 41 voltage INFINITI_HVBAT_CELL_41_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 42 voltage INFINITI_HVBAT_CELL_42_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 43 voltage INFINITI_HVBAT_CELL_43_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 44 voltage INFINITI_HVBAT_CELL_44_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 45 voltage INFINITI_HVBAT_CELL_45_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 46 voltage INFINITI_HVBAT_CELL_46_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 47 voltage INFINITI_HVBAT_CELL_47_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 48 voltage INFINITI_HVBAT_CELL_48_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 49 voltage INFINITI_HVBAT_CELL_49_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 50 voltage INFINITI_HVBAT_CELL_50_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 51 voltage INFINITI_HVBAT_CELL_51_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 52 voltage INFINITI_HVBAT_CELL_52_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 53 voltage INFINITI_HVBAT_CELL_53_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 54 voltage INFINITI_HVBAT_CELL_54_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 55 voltage INFINITI_HVBAT_CELL_55_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 56 voltage INFINITI_HVBAT_CELL_56_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 57 voltage INFINITI_HVBAT_CELL_57_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 58 voltage INFINITI_HVBAT_CELL_58_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 59 voltage INFINITI_HVBAT_CELL_59_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 60 voltage INFINITI_HVBAT_CELL_60_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 61 voltage INFINITI_HVBAT_CELL_61_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 62 voltage INFINITI_HVBAT_CELL_62_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 63 voltage INFINITI_HVBAT_CELL_63_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 64 voltage INFINITI_HVBAT_CELL_64_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 65 voltage INFINITI_HVBAT_CELL_65_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 66 voltage INFINITI_HVBAT_CELL_66_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 67 voltage INFINITI_HVBAT_CELL_67_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 68 voltage INFINITI_HVBAT_CELL_68_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 69 voltage INFINITI_HVBAT_CELL_69_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 70 voltage INFINITI_HVBAT_CELL_70_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 71 voltage INFINITI_HVBAT_CELL_71_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 72 voltage INFINITI_HVBAT_CELL_72_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 73 voltage INFINITI_HVBAT_CELL_73_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 74 voltage INFINITI_HVBAT_CELL_74_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 75 voltage INFINITI_HVBAT_CELL_75_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 76 voltage INFINITI_HVBAT_CELL_76_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 77 voltage INFINITI_HVBAT_CELL_77_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 78 voltage INFINITI_HVBAT_CELL_78_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 79 voltage INFINITI_HVBAT_CELL_79_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 80 voltage INFINITI_HVBAT_CELL_80_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 81 voltage INFINITI_HVBAT_CELL_81_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 82 voltage INFINITI_HVBAT_CELL_82_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 83 voltage INFINITI_HVBAT_CELL_83_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 84 voltage INFINITI_HVBAT_CELL_84_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 85 voltage INFINITI_HVBAT_CELL_85_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 86 voltage INFINITI_HVBAT_CELL_86_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 87 voltage INFINITI_HVBAT_CELL_87_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 88 voltage INFINITI_HVBAT_CELL_88_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 89 voltage INFINITI_HVBAT_CELL_89_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 90 voltage INFINITI_HVBAT_CELL_90_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 91 voltage INFINITI_HVBAT_CELL_91_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 92 voltage INFINITI_HVBAT_CELL_92_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 93 voltage INFINITI_HVBAT_CELL_93_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 94 voltage INFINITI_HVBAT_CELL_94_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 95 voltage INFINITI_HVBAT_CELL_95_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

HV battery cell 96 voltage INFINITI_HVBAT_CELL_96_V_V2

  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2011 to 2019.

Draw

Power used by air conditioning INFINITI_AC_PWR_EST

  • Service 22DID 1261
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

In testing for 2011 to 2019.

Power used by auxiliary equipment (lights, radio, navigation, rear defroster, etc...). INFINITI_AUX_PWR

  • Service 22DID 1152
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 W
Unit
W

In testing for 2011 to 2019.

Power used by both the A/C and PTC heater. INFINITI_AC_PWR

  • Service 22DID 1151
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×250
Range
0 to 63750 W
Unit
W

In testing for 2011 to 2019.

Power used by cabin positive temperature coefficient (PTC) heaters. INFINITI_HTR_PWR

  • Service 22DID 1262
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×250
Range
0 to 63750 W
Unit
W

In testing for 2011 to 2019.

Statistics

Quick charge count INFINITI_L1L2CHRG_CNT

Increments each time an L1/L2 charge occurs, even if only partially.

  • Service 22DID 1205
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Quick charge count INFINITI_QCKCHRG_CNT

Increments each time a quick charge occurs, even if only partially.

  • Service 22DID 1203
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Climate

A/C state INFINITI_AC_ON

  • Service 22DID 1106
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

A/C status INFINITI_AC_STATUS

  • Service 22DID 4007
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Off or on

In testing for 2011 to 2019.

Air conditioning compressor speed INFINITI_AC_COMP_RPM

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Air conditioning on INFINITI_HVAC_AC_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Ambient air temperature INFINITI_AAT

  • Service 22DID 4008
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Ambient air temperature INFINITI_AAT_V2

  • Service 22DID 115D
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.9−40.9
Range
-36.81 to 192.69 °F
Unit
°F

In testing for 2011 to 2019.

Ambient air temperature, climate module INFINITI_HVAC_AAT

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Blower on INFINITI_HVAC_FAN_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Blower voltage INFINITI_HVAC_BLOWER_V

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2011 to 2019.

Cabin temperature INFINITI_HVAC_CABIN_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

ECO mode state INFINITI_ECO_MODE

  • Service 22DID 1318
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0ECO_OFFECO is off
16ECO_ON_1ECO is on
17ECO_ON_2ECO is on

In testing for 2011 to 2019.

Engine coolant temperature INFINITI_ECT

  • Service 22DID F467
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Evaporator temperature INFINITI_HVAC_EVAP_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Rear heater state INFINITI_HTR_REAR

  • Service 22DID 110F
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
162HEATER_ONHeater is on

In testing for 2011 to 2019.

Sun load INFINITI_HVAC_SUNLOAD

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Control

Accelerator pedal position INFINITI_APP

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2011 to 2019.

Anti-lock brake steering angle INFINITI_ABS_STEER_ANG

  • Service 22DID 1208
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2011 to 2019.

Brake master cylinder pressure INFINITI_BRAKE_MC_P

  • Service 22DID 1209
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.536
Range
0 to 42666.015
Unit
Raw value

In testing for 2011 to 2019.

Brake switch INFINITI_BRAKE_SWITCH

  • Service 22DID 1305
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2019.

BRAKE SWITCH, number 1 INFINITI_BRAKE_SWITCH_NUMBER_1

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

BRAKE SWITCH, number 2 INFINITI_BRAKE_SWITCH_NUMBER_2

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

E-pedal mode INFINITI_EPEDAL_MODE

  • Service 22DID 131A
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0EPEDAL_OFFE-pedal mode is off
4EPEDAL_ONE-pedal mode is on

In testing for 2011 to 2019.

Left turn signal INFINITI_TURN_SIGNAL_LEFT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Main brake cylinder pressure INFINITI_MAIN_BRAKE_CYL_P

  • Service 22DID 4B0E
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2011 to 2019.

Parking brake INFINITI_PARKING_BRAKE

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Right turn signal INFINITI_TURN_SIGNAL_RIGHT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Steering wheel angle INFINITI_STEER_ANGLE

Negative values are clockwise, positive values are counter-clockwise.

  • Service 22DID 0110
  • Module723 → 735
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2011 to 2019.

Wired brake contact INFINITI_WIRED_BRAKE_CONTACT

  • Service 22DID 2026
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Yaw rate INFINITI_YAW_RATE

  • Service 22DID 0101
  • Module723 → 735
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2011 to 2019.

Cruise control

Cruise control set speed INFINITI_CC_S

  • Service 22DID 122B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 3686 km/h
Unit
km/h

In testing for 2011 to 2019.

Radar distance INFINITI_RADAR_DISTANCE

  • Service 22DID 0107
  • Module723 → 735
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 m
Unit
m

In testing for 2011 to 2019.

Relative speed INFINITI_RADAR_SPEED

  • Service 22DID 0108
  • Module723 → 735
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 m/s
Unit
m/s

In testing for 2011 to 2019.

Engine

A/F ratio adj INFINITI_F_RAT_ADJ

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2011 to 2019.

Air conditioning compressor INFINITI_AC_COMP

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive coupling temperature INFINITI_AWD_COUPLING_T

  • Service 22DID 1114
  • Module748 → 768
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive electronic traction support solenoid INFINITI_AWD_ELECTRONIC

  • Service 22DID 1103
  • Module748 → 768
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val50
Range
0 to 0.02
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive estimated engine torque INFINITI_AWD_ESTIMATED_ENG_TQ

  • Service 22DID 1105
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply. The value is signed.

Formula
val×52
Range
-2.5 to 0
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive request engine torque INFINITI_AWD_REQ_ENG_TQ

  • Service 22DID 1104
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply. The value is signed.

Formula
val×52
Range
-2.5 to 0
Unit
Off or on

In testing for 2011 to 2019.

Alternator power INFINITI_ALTERNATOR_POWER

  • Service 22DID 2057
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

In testing for 2011 to 2019.

Auto emergency braking system request INFINITI_AUTO_EMERGENCY

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Available motor, maximum output INFINITI_AVAILABLE_MOTOR_MAX

  • Service 22DID 1144
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Average knock signal INFINITI_AVG_KNOCK_SIG

  • Service 22DID FDC2
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

In testing for 2011 to 2019.

AWD, target traction control torque INFINITI_AWD_TGT_TRACTION

  • Service 22DID 1107
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val×2
Range
0 to 2
Unit
Off or on

In testing for 2011 to 2019.

Base injection timing INFINITI_BASE_INJ_TIM

  • Service 22DID 1207
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99 ms
Unit
ms

In testing for 2011 to 2019.

Boost pressure wastegate control INFINITI_BOOST_P_WASTEGATE

  • Service 22DID FE1D
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Braking detected multiplex signal INFINITI_BRAKING_DETECTED

  • Service 22DID 200F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Butane percentage INFINITI_BUTANE_PERCENTAGE

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×781320000
Range
0 to 99.61 %
Unit
%

In testing for 2011 to 2019.

Camshaft adv angle INFINITI_CAM_ADV_ANG

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2011 to 2019.

Camshaft phase, measured position INFINITI_CAM_DEPHASE_MEAS_POS

  • Service 22DID 2255
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 %
Unit
%

In testing for 2011 to 2019.

Camshaft phaser solenoid valve duty cycle INFINITI_CAM_DEPHASE_SOLENOID

  • Service 22DID 2033
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2011 to 2019.

Camshaft valve duty INFINITI_CAM_VLV_DUTY

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2011 to 2019.

Cold starting programming INFINITI_COLD_STARTING

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Combustion misfire counter INFINITI_COMBUSTION_MIS_CNT

  • Service 22DID 2874
  • ModuleDA15 → 15
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Coolant temperature INFINITI_ECT_7E0

  • Service 22DID 1406
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Cooling fan high INFINITI_COOLING_FAN_HIGH

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Cooling fan low INFINITI_COOLING_FAN_LOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Crank signal, correction INFINITI_CRANK_SIG_CORR

  • Service 22DID 2161
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Cruise control INFINITI_CRUISE_CTRL

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Duration of - button press INFINITI_DUR_BUTTON_PRESS_7E0

  • Service 22DID 207C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2011 to 2019.

Duration of + button press INFINITI_DUR_BUTTON_PRESS

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2011 to 2019.

Duration of resume button press INFINITI_DUR_RESUME_BUTTON

  • Service 22DID 207A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2011 to 2019.

Duration of suspend button press INFINITI_DUR_SUSPEND_BUTTON

  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2011 to 2019.

Electric fuel pump learning value INFINITI_EFP_LEARNING

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val65535−0.5
Range
-0.5 to 0.5 %
Unit
%

In testing for 2011 to 2019.

Engine control module temperature INFINITI_ENG_CTRL_MODULE_T

  • Service 22DID FDDA
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2019.

Engine oil temperature INFINITI_EOT

  • Service 22DID 2095
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2011 to 2019.

Engine oil temperature INFINITI_EOT_DA15

  • Service 22DID 2007
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2019.

Engine oil temperature INFINITI_EOT_V2

  • Service 22DID 111F
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2019.

Engine reference torque INFINITI_ENG_REFERENCE_TQ

  • Service 22DID 2069
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine RPM INFINITI_RPM

  • Service 22DID 1255
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32767 to 32767
Unit
Number

In testing for 2011 to 2019.

Engine starts after PF regen INFINITI_ENG_STARTS_AFTER_PF

  • Service 22DID 30D9
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Engine torque INFINITI_ENG_TQ

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−400
Range
-400 to 32367 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine torque INFINITI_ENG_TQ_DA15

  • Service 22DID 2004
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−400
Range
-400 to 1647 N·m
Unit
N·m

In testing for 2011 to 2019.

Estimated manifold pressure INFINITI_ESTIMATED_MANIFOLD_P

  • Service 22DID 24D7
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2011 to 2019.

EVAP purge duty INFINITI_EVAP_PURGE_DUTY

  • Service 22DID 1110
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2011 to 2019.

Front pinion angle INFINITI_FRONT_PINION_ANG

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2011 to 2019.

Gear INFINITI_GEAR

  • Service 22DID 1156
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1PARKPark
2REVERSEReverse
3NEUTRALNeutral
4DRIVEDrive
7ECOEco

In testing for 2011 to 2019.

Head lamp INFINITI_HEAD_LAMP

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bit 56 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Headlamp level INFINITI_HEADLAMP_LEVEL

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×49125
Range
0 to 25689 %
Unit
%

In testing for 2011 to 2019.

Height sensor initial value front INFINITI_HEIGHT_SENS_INIT_FRONT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×51024
Range
0 to 319.99 V
Unit
V

In testing for 2011 to 2019.

Height sensor initial value rear INFINITI_HEIGHT_SENS_INIT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×51024
Range
0 to 319.99 V
Unit
V

In testing for 2011 to 2019.

Height sensor signal front INFINITI_HEIGHT_SENS_SIG

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×5+1024
Range
0 to 328699 V
Unit
V

In testing for 2011 to 2019.

Height sensor signal rear INFINITI_HEIGHT_SENS_SIG_REAR

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×5+1024
Range
0 to 328699 V
Unit
V

In testing for 2011 to 2019.

High voltage coolant temperature INFINITI_HIGH_V_ECT

  • Service 22DID 111A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 °C
Unit
°C

In testing for 2011 to 2019.

Idle control mode INFINITI_IDLE_CTRL_MODE

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Ignition advance INFINITI_IGN_ADVANCE

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×-1+112
Range
-143 to 112
Unit
Number

In testing for 2011 to 2019.

Ignition timing advance INFINITI_IGN_TIM_ADVANCE

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×-1+110
Range
-145 to 110 °
Unit
°

In testing for 2011 to 2019.

Ih_defactrposition INFINITI_IH_DEFACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_feetventactrposition INFINITI_IH

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_leftmixactrposition INFINITI_IH_LEFTMIXACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_rearmixactrposition INFINITI_IH_REARMIXACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_recyactrposition INFINITI_IH_RECYACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_reserveactrposition INFINITI_IH_RESERVEACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Ih_rightmixactrposition INFINITI_IH_RIGHTMIXACTRPOSITION

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Inlet air temperature INFINITI_INLET_AIR_T

  • Service 22DID 243F
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2019.

Inlet pressure INFINITI_INLET_P

  • Service 22DID 2401
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2011 to 2019.

Input possible power INFINITI_INPUT_POSSIBLE_POWER

  • Service 22DID CF1B
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 kW
Unit
kW

In testing for 2011 to 2019.

Input possible power, short INFINITI_INPUT_POSSIBLE_POWER_SHORT

  • Service 22DID CF1C
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 kW
Unit
kW

In testing for 2011 to 2019.

Intake camshaft advance, bank 2 INFINITI_CAM_ADV_B2

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2011 to 2019.

Intake camshaft phase position target INFINITI_INT_CAM_PHASE_POS_TGT

  • Service 22DID 2030
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 °
Unit
°

In testing for 2011 to 2019.

Intake valve timing solenoid duty, bank 2 INFINITI_CAM_DUTY_B2

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2011 to 2019.

Knock value 1 INFINITI_KNOCK_1

  • Service 22DID FD7F
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1613107
Range
0 to 80 V
Unit
V

In testing for 2011 to 2019.

Knock value 2 INFINITI_KNOCK_2

  • Service 22DID FD7E
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1613107
Range
0 to 80 V
Unit
V

In testing for 2011 to 2019.

Low-pressure fuel pump drive duty INFINITI_LPLI_PMP_PWM_SIG

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val×0.0015259
Range
0 to 99.99 %
Unit
%

In testing for 2011 to 2019.

Manifold air temperature INFINITI_MANIFOLD_AIR_T

  • Service 22DID 244D
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2019.

Manifold pressure INFINITI_MANIFOLD_P

  • Service 22DID 140E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000
Range
0 to 255000
Unit
Raw value

In testing for 2011 to 2019.

Manual or assisted parking brake INFINITI_MANUAL_OR_ASSISTED

  • Service 22DID 222B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Mass air flow INFINITI_MAF

  • Service 22DID 1209
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2011 to 2019.

Mass air flow sensor voltage, bank 2 INFINITI_MAF_V_B2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2011 to 2019.

Misfire counter 1 INFINITI_MIS_CNT_1

  • Service 22DID FD7A
  • ModuleDA15 → 15
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Misfire counter 2 INFINITI_MIS_CNT_2

  • Service 22DID FD7B
  • ModuleDA15 → 15
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Misfire counter 3 INFINITI_MIS_CNT_3

  • Service 22DID FD7C
  • ModuleDA15 → 15
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Misfire counter 4 INFINITI_MIS_CNT_4

  • Service 22DID FD7D
  • ModuleDA15 → 15
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Motor power INFINITI_MOTOR_PWR

  • Service 22DID 1146
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×40
Range
0 to 2621400 W
Unit
W

In testing for 2011 to 2019.

Motor power consumption INFINITI_MOTOR_POWER_CONS

  • Service 22DID 1146
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2011 to 2019.

Motor regenerative power, maximum INFINITI_MOTOR_REGENERABLE_MAX

  • Service 22DID 1145
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Motor torque, actual INFINITI_MOTOR_TQ

  • Service 22DID 1254
  • Module797 → 79A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 N·m
Unit
N·m

In testing for 2011 to 2019.

Motor torque, nominal INFINITI_MOTOR_TQ_NOMINAL

  • Service 22DID 1128
  • Module797 → 79A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 N·m
Unit
N·m

In testing for 2011 to 2019.

Number of abnormal cc/sl transitions INFINITI_NUM_ABNORMAL_CC_SL

  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Oh_defactrreq INFINITI_OH_DEFACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_feetventactrreq INFINITI_OH_FEETVENTACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_leftmixactrreq INFINITI_OH_LEFTMIXACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_rearmixactrreq INFINITI_OH_REARMIXACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_recyactrreq INFINITI_OH_RECYACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_reserveactrreq INFINITI_OH_RESERVEACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oh_rightmixactrreq INFINITI_OH_RIGHTMIXACTRREQ

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2019.

Oil temperature INFINITI_OIL_T

  • Service 22DID 2113
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2019.

Output possible power INFINITI_OUTPUT_POSSIBLE

  • Service 22DID CF19
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 kW
Unit
kW

In testing for 2011 to 2019.

Output possible power, short INFINITI_OUTPUT_POSSIBLE_POWER

  • Service 22DID CF1A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 kW
Unit
kW

In testing for 2011 to 2019.

Power switch INFINITI_IGN

  • Service 22DID 1304
  • Module797 → 79A
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Refrigerant pressure INFINITI_REFRIGERANT_P

  • Service 22DID 222A
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2011 to 2019.

Refrigerant pressure sensor INFINITI_REFRIGERANT_P_SENS

  • Service 22DID 112E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val500000
Range
0 to 0.0005
Unit
Raw value

In testing for 2011 to 2019.

Reverse INFINITI_REVERSE

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bit 57 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Selector position INFINITI_SELECTOR_POS

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Starter button INFINITI_STARTER_BUTTON

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Starter wear counter INFINITI_STARTER_WEAR_CNT

  • Service 22DID 22AA
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 63 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2011 to 2019.

Steer angle INFINITI_STEER_ANG

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °
Unit
°

In testing for 2011 to 2019.

Steering angle INFINITI_STEER_ANG_DA2D

  • Service 22DID 0100
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276 to 3276 °
Unit
°

In testing for 2011 to 2019.

Swivel angle left INFINITI_SWIVEL_ANG_LEFT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val10−32000
Range
-32000 to -25447 °
Unit
°

In testing for 2011 to 2019.

Swivel angle right INFINITI_SWIVEL_ANG_RIGHT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val10−32000
Range
-32000 to -25447 °
Unit
°

In testing for 2011 to 2019.

Swivel sensor left INFINITI_SWIVEL_SENS_LEFT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10−32000
Range
-32000 to -25447 °
Unit
°

In testing for 2011 to 2019.

Swivel sensor right INFINITI_SWIVEL_SENS_RIGHT

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val10−32000
Range
-32000 to -25447 °
Unit
°

In testing for 2011 to 2019.

Tank pressure INFINITI_TANK_P

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2011 to 2019.

Target motor torque INFINITI_TGT_MOTOR_TQ

  • Service 22DID 1128
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 N·m
Unit
N·m

In testing for 2011 to 2019.

Throttle opening INFINITI_THROTTLE_OPENING

  • Service 22DID 140F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×720
Range
0 to 89.25 °
Unit
°

In testing for 2011 to 2019.

Traction control/anti-yaw control INFINITI_TRACTION_CTRL_ANTI

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Traction motor temperature INFINITI_TRACTION_MOTOR_T

  • Service 22DID 111C
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Vapor lock temperature INFINITI_VAPOR_LOCK_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2011 to 2019.

Variable valve timing oil temperature INFINITI_VARIABLE_VLV_TIM_OIL_T

  • Service 22DID 111F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2019.

Variable valve timing oil temperature INFINITI_VVT_EOT

  • Service 22DID 1266
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3128−273
Range
-273 to 1262 °C
Unit
°C

In testing for 2011 to 2019.

Water pump 1 INFINITI_WATER_PMP_1

  • Service 22DID 1104
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 %
Unit
%

In testing for 2011 to 2019.

Water pump 1, target duty INFINITI_WATER_PMP_1_TGT_DUTY

  • Service 22DID 1105
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 %
Unit
%

In testing for 2011 to 2019.

Fuel

Air/fuel ratio adjustment, bank 2 INFINITI_AF_ADJ_B2

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2011 to 2019.

Fuel base pulse width INFINITI_FUEL_BASE_WIDTH

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99 ms
Unit
ms

In testing for 2011 to 2019.

Fuel flow INFINITI_FUEL_FLOW

  • Service 22DID 28C6
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2563125
Range
0 to 5368
Unit
Raw value

In testing for 2011 to 2019.

Fuel level input INFINITI_FLI_INPUT

  • Service 22DID 1114
  • ModuleDA18 → 18
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val25
Range
0 to 10.2 V
Unit
V

In testing for 2011 to 2019.

Fuel pump flow INFINITI_FUEL_PMP_FLOW

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 g/s
Unit
g/s

In testing for 2011 to 2019.

Fuel rail temperature INFINITI_FUEL_RAIL_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2011 to 2019.

Fuel tank temperature INFINITI_FUEL_TANK_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2011 to 2019.

Fuel temperature INFINITI_FUEL_T

  • Service 22DID 1111
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2019.

Fuel temperature INFINITI_FUEL_T_7E0

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2019.

Remaining fuel INFINITI_REMAINING_FUEL

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2011 to 2019.

Lights

Stop warning light INFINITI_STOP_WARN_LIGHT

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Movement

Change of vehicle speed unit INFINITI_CHANGE_VSS_UNIT

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Cruise control/speed limiter buttons INFINITI_CRUISE_CTRL_SPD

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Current engine speed INFINITI_CURRENT_RPM

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×252
Range
0 to 819187 rpm
Unit
rpm

In testing for 2011 to 2019.

Engine speed INFINITI_TCM_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID 1204
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Engine speed, alternate INFINITI_TCM_RPM_2

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Fan speed INFINITI_FAN_SPD

  • Service 22DID 912E
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2011 to 2019.

Fan speed INFINITI_FAN_SPD_DADB

  • Service 22DID 91F0
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Input speed INFINITI_TCM_INPUT_RPM

  • Service 22DID 1201
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Motor RPM INFINITI_MOTOR_RPM

  • Service 22DID 1254
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2011 to 2019.

Output speed INFINITI_OUTPUT_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Primary pulley speed INFINITI_TCM_PRI_RPM

  • Service 22DID 1202
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Primary pulley speed, alternate INFINITI_TCM_PRI_RPM_2

  • Service 22DID 120D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Secondary pulley speed INFINITI_TCM_SEC_RPM

  • Service 22DID 1203
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Secondary pulley speed, alternate INFINITI_TCM_SEC_RPM_2

  • Service 22DID 120E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Turbine speed INFINITI_TURBINE_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Vehicle speed INFINITI_TCM_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Vehicle speed INFINITI_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 2003
  • ModuleDADA → DAF1DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2011 to 2019.

Vehicle speed INFINITI_VSS_DADA

  • Service 22DID 1102
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Vehicle speed INFINITI_VSS_V2

Pelican can show this parameter as the speed.

  • Service 22DID 121A
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2011 to 2019.

Vehicle speed INFINITI_VSS_V3

  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2011 to 2019.

Vehicle speed multiplexed information INFINITI_VSS_MULTIPLEXED

  • Service 22DID 2225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Vehicle speed, vehicle control module INFINITI_VSS_VCM

  • Service 22DID 1102
  • Module797 → 79A
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Water pump 1 current speed duty INFINITI_WATER_PMP_1_CURRENT

  • Service 22DID 1106
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 %
Unit
%

In testing for 2011 to 2019.

Tires

All-wheel drive front left wheel speed INFINITI_AWD_FL_WHL_SPD

  • Service 22DID 1202
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val×25665535
Range
0 to 0.0039
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive front right wheel speed INFINITI_AWD_FR_WHL_SPD

  • Service 22DID 1201
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val×25665535
Range
0 to 0.0039
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive rear left wheel speed INFINITI_AWD_RL_WHL_SPD

  • Service 22DID 1204
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val×25665535
Range
0 to 0.0039
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive rear right wheel speed INFINITI_AWD_RR_WHL_SPD

  • Service 22DID 1203
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val×25665535
Range
0 to 0.0039
Unit
Off or on

In testing for 2011 to 2019.

Front left tire pressure INFINITI_FL_TIRE_P

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0201
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front left tire pressure INFINITI_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

In testing for 2011 to 2019.

Front left tire pressure INFINITI_TP_FL_743

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front left tire pressure INFINITI_TP_FL_V2

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0201
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front left tire pressure, warning INFINITI_TPW_FL

  • Service 22DID 020D
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front left wheel speed INFINITI_FL_WHL_SPD

  • Service 22DID 4B00
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2011 to 2019.

Front right tire pressure INFINITI_FR_TIRE_P

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0202
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front right tire pressure INFINITI_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0E25
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

In testing for 2011 to 2019.

Front right tire pressure INFINITI_TP_FR_743

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0E25
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front right tire pressure INFINITI_TP_FR_V2

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0202
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front right tire pressure, warning INFINITI_TPW_FR

  • Service 22DID 020E
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Front right wheel speed INFINITI_FR_WHL_SPD

  • Service 22DID 4B01
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2011 to 2019.

Rear left tire pressure INFINITI_RL_TIRE_P

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0204
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear left tire pressure INFINITI_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0E28
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

In testing for 2011 to 2019.

Rear left tire pressure INFINITI_TP_RL_743

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0E28
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear left tire pressure INFINITI_TP_RL_V2

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0204
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear left tire pressure, warning INFINITI_TPW_RL

  • Service 22DID 0210
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear left wheel speed INFINITI_RL_WHL_SPD

  • Service 22DID 4B02
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2011 to 2019.

Rear right tire pressure INFINITI_RR_TIRE_P

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0203
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear right tire pressure INFINITI_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0E27
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

In testing for 2011 to 2019.

Rear right tire pressure INFINITI_TP_RR_743

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0E27
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear right tire pressure INFINITI_TP_RR_V2

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0203
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear right tire pressure, warning INFINITI_TPW_RR

  • Service 22DID 020F
  • Module758 → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Rear right wheel speed INFINITI_RR_WHL_SPD

  • Service 22DID 4B03
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2011 to 2019.

Wheel 1 pressure INFINITI_WHL_1_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Wheel 2 pressure INFINITI_WHL_2_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Wheel 3 pressure INFINITI_WHL_3_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Wheel 4 pressure INFINITI_WHL_4_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2011 to 2019.

Transmission

Acceleration sensor voltage INFINITI_TCM_G_V

  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.27 to 3.27 V
Unit
V

In testing for 2011 to 2019.

All-wheel drive clutch high temperature signal 1 INFINITI_AWD_CLU_HIGH_T_SIG_1

  • Service 22DID 1314
  • Module748 → 768
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive clutch high temperature signal 2 INFINITI_AWD_CLU_HIGH_T_SIG_2

  • Service 22DID 1315
  • Module748 → 768
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Engage reverse gear INFINITI_ENGAGE_REVERSE_GEAR

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Engine torque INFINITI_TCM_ENG_TQ

  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine torque, active INFINITI_TCM_ENG_TQ_ACT

  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine torque, transmitted INFINITI_TCM_ENG_TQ_TX

  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Estimated vehicle speed INFINITI_TCM_VSS_EST

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Fluid temperature sensor voltage INFINITI_TCM_ATF_T_V

  • Service 22DID 1207
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Gearbox ratio INFINITI_GEARBOX_RAT

  • Service 22DID 2C04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Input speed, alternate INFINITI_TCM_INPUT_RPM_2

  • Service 22DID 120C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Isolation solenoid 1 current INFINITI_TCM_ISO_1_C

  • Service 22DID 1219
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Isolation solenoid 2 current INFINITI_TCM_ISO_2_C

  • Service 22DID 121A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Line pressure INFINITI_TCM_LINE_P

  • Service 22DID 110E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Lubrication pressure INFINITI_TCM_LUBE_P

  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270 kPa
Unit
kPa

In testing for 2011 to 2019.

Primary pressure sensor voltage INFINITI_TCM_PRI_P_V

  • Service 22DID 1206
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Primary pulley pressure INFINITI_TCM_PRI_P

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2011 to 2019.

Primary pulley pressure count INFINITI_TCM_PRI_P_RAW

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Primary pulley torque INFINITI_TCM_PRI_TQ

  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Primary solenoid current INFINITI_TCM_PRI_SOL_C

  • Service 22DID 121B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Primary solenoid monitor current INFINITI_TCM_PRI_SOL_MON

  • Service 22DID 1221
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Pulley ratio INFINITI_TCM_PULLEY_RAT

  • Service 22DID 1210
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2011 to 2019.

Requested engine speed INFINITI_TCM_REQ_RPM

  • Service 22DID 1114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2019.

Requested torque INFINITI_TCM_REQ_TQ

  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2011 to 2019.

Requested torque delta INFINITI_TCM_REQ_TQ_D

  • Service 22DID 1112
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2011 to 2019.

Secondary pressure sensor voltage INFINITI_TCM_SEC_P_V

  • Service 22DID 1205
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Secondary pulley pressure INFINITI_TCM_SEC_P

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2011 to 2019.

Secondary pulley pressure count INFINITI_TCM_SEC_P_RAW

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Secondary solenoid current INFINITI_TCM_SEC_SOL_C

  • Service 22DID 121C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Secondary solenoid monitor current INFINITI_TCM_SEC_SOL_MON

  • Service 22DID 1222
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Select solenoid current INFINITI_TCM_SEL_SOL_C

  • Service 22DID 121D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Select solenoid monitor current INFINITI_TCM_SEL_SOL_MON

  • Service 22DID 1223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Solenoid 1 monitor current INFINITI_TCM_SOL_MON_1

  • Service 22DID 121E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Solenoid 2 monitor current INFINITI_TCM_SOL_MON_2

  • Service 22DID 121F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Target primary pulley pressure INFINITI_TCM_PRI_P_TGT

  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Target pulley ratio INFINITI_TCM_PULLEY_RAT_TGT

  • Service 22DID 1218
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2011 to 2019.

Target secondary pulley pressure INFINITI_TCM_SEC_P_TGT

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Target select pressure INFINITI_TCM_SEL_P_TGT

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Torque converter slip INFINITI_TQ_CONV_SLIP

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2011 to 2019.

Torque ratio INFINITI_TCM_TQ_RAT

  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×577160000
Range
0 to 236
Unit
Number

In testing for 2011 to 2019.

Transmission ATF deterioration date INFINITI_TRANS_ATF

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2019.

Transmission fluid temperature INFINITI_ATF_T

  • Service 22DID 2170
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Transmission fluid temperature INFINITI_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Transmission fluid temperature, variant 1 INFINITI_ATF_T_VAR_1

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2011 to 2019.

Transmission fluid temperature, variant 1 INFINITI_ATF_T_VAR_1_7E1

  • Service 22DID 0230
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2011 to 2019.

Transmission fluid temperature, variant 2 INFINITI_ATF_T_VAR_2

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2011 to 2019.

Transmission fluid temperature, variant 2 INFINITI_ATF_T_VAR_2_7E1

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2011 to 2019.

Transmission work hours INFINITI_TRANS_WORK_HOURS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2011 to 2019.

Transmission work hours warm engine INFINITI_TRANS_WORK_HOURS_WARM_ENG

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2011 to 2019.

Transmission-A INFINITI_TRANS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Transmission-B INFINITI_TRANS_B

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Vehicle speed sensor INFINITI_TCM_VSS_SENS

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Trips

Battery controller distance counter INFINITI_BAT_CONTROLLER_DIST

  • Service 21PID 0C
  • Module79B → 7BB
  • Every3600 s
  • Testing

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4500
Unit
Number

In testing for 2011 to 2019.

Odometer INFINITI_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 0E01
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

In testing for 2011 to 2019.

Odometer, meter group 1 INFINITI_MTR_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 56 to 79 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2011 to 2019.

Odometer, meter group 1 INFINITI_ODO_METER

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 56 to 79 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2011 to 2019.

Range remaining INFINITI_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 0E2E
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2047 km
Unit
km

In testing for 2011 to 2019.

Range shown on the display INFINITI_RANGE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 1155
  • Module797 → 79A
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2011 to 2019.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.