HV battery state of charge EQV_HV_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x069E = 1694 → 1694100 = 16.94 %

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Coolant pump voltage, M13/5 EQV_CLT_PMP_V_M13_5

  • Service 22DID 5504
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 V
Unit
V

In testing for 2020 to 2026.

Coolant pump voltage, M43/1 EQV_CLT_PMP_V_M43_1

  • Service 22DID 5506
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 V
Unit
V

In testing for 2020 to 2026.

DC converter requested voltage EQV_CNVRTR_REQ_VConfirmed

  • Service 22DID 6071
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 1638.375 V
Unit
V

0x1798 = 6040 → 6040×25010000 = 151 V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

High voltage PTC heater voltage, N33/5 EQV_HIGH_V_PTC_HEATER_V_5

  • Service 22DID 550A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 V
Unit
V

In testing for 2020 to 2026.

HV battery amperage EQV_HV_AConfirmed

  • Service 22DID 6053
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery coolant temperature EQV_HV_COOLANT_TConfirmed

  • Service 22DID 2526
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
0 to 100 °C
Unit
°C

0x0000 = 0 → 0×125010000 = 0 °C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery state of charge EQV_HV_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x069E = 1694 → 1694100 = 16.94 %

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery voltage EQV_HV_VConfirmed

  • Service 22DID 6075
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638.375 V
Unit
V

0x0010 = 16 → 16×251000 = 0.4 V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Engine

DC/DC module state, boost EQV_DC_DC_MODULE_ST

  • Service 22DID 6074
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2020 to 2026.

Distance to next service EQV_SERVICE_DISTConfirmed

  • Service 22DID 6504
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Mercedes-Benz EQV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1F40 = 8000 → 8,000 km

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Fan motor duty, M4/7 EQV_FAN_MOTOR_DUTY_M4_7

  • Service 22DID D50A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

High voltage PTC heater state, N33/5 EQV_HIGH_V_PTC_HEATER_ST_5

  • Service 22DID 550C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Power electric unit temperature sensor, B11/5 EQV_POWER_ELEC_UNIT_T_5

  • Service 22DID 2525
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 °C
Unit
°C

In testing for 2020 to 2026.

Radiator grill, M2/39 position EQV_RADIATOR_GRILL_M2_39_POS

  • Service 22DID 550F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Radiator grill, M2/39 status, closing EQV_RADIATOR_GRILL_M2_39

  • Service 22DID 5510
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Remaining operating time EQV_REMAINING_OP_TIME

  • Service 22DID 6503
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−2048
Range
-2048 to 63487
Unit
Raw value

In testing for 2020 to 2026.

Terminal 15 status EQV_KLEMME_15_STAT

  • Service 22DID 3008
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Terminal 50 status EQV_KLEMME_50_STAT

  • Service 22DID 3505
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Terminal 87 feedback EQV_KLEMME_87_FEEDBACK

  • Service 22DID 2006
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 1279 V
Unit
V

In testing for 2020 to 2026.

Terminal 87 status EQV_KLEMME_87_STAT

  • Service 22DID D027
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.