MG MG5

Parameters

The MG MG5 has 120 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery health MG5_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x2530 = 9520 → 9520100 = 95.2 %

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

HV battery coolant temperature MG5_HVBAT_COOLANT_TEMPConfirmed

  • Service 22DID B05C
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x64 = 100 → 1002−40 = 10 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery current MG5_HVBAT_CURRENTConfirmed

  • Service 22DID B043
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
-1000 to 638.375 A
Unit
A

0x7F9C = 32668 → 3266840−1000 = -183.3 A

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery health MG5_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x2530 = 9520 → 9520100 = 95.2 %

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery temperature MG5_HVBAT_TEMPConfirmed

  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x65 = 101 → 1012−40 = 10.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery voltage MG5_HVBAT_VOLTAGEConfirmed

  • Service 22DID B042
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 500 V
Unit
V

0x04F3 = 1267 → 12674 = 316.75 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Knock sensor voltage MG5_KNOCK_SNS_V

  • Service 22DID B140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

EVCC

Charging MG5_EVCC_CHARGING

  • Service 22DID B00F
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2024 to 2026. Not supported for 2021 to 2023.

Max current MG5_EVCC_MAX_CURRENT

  • Service 22DID B003
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.869565 A
Unit
A

In testing for 2020, 2024 to 2026. Not supported for 2021 to 2023.

Voltage MG5_EVCC_VOLTAGE

  • Service 22DID B010
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val97
Range
0 to 675.618556 V
Unit
V

In testing for 2020, 2024 to 2026. Not supported for 2021 to 2023.

Internal

Battery management system status MG5_BMS_STATUSConfirmed

  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery bus voltage MG5_HVBAT_BUS_VOLTAGEConfirmed

  • Service 22DID B041
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1023.75 V
Unit
V

0x04F4 = 1268 → 12684 = 317 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery internal resistance MG5_HVBAT_RESISTANCEConfirmed

  • Service 22DID B045
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 8191.5
Unit
Number

0x2AFB = 11003 → 110032 = 5,501.5

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery raw charge MG5_HVBAT_RAW_SOCConfirmed

HV battery raw charge

  • Service 22DID B046
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0002 = 2 → 210 = 0.2 %

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 01

HV battery module 01 max temperature MG5_HVBAT_CMU01_MAXTEMP

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing for 2020, 2022 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2020, 2024 to 2026. Supported for 2021. Not supported for 2022 to 2023.

HV battery module 01 max voltage MG5_HVBAT_CMU01_MAXVOLT

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing for 2020, 2022 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2020, 2024 to 2026. Supported for 2021. Not supported for 2022 to 2023.

HV battery module 01 min temperature MG5_HVBAT_CMU01_MINTEMP

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing for 2020, 2022 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2020, 2024 to 2026. Supported for 2021. Not supported for 2022 to 2023.

HV battery module 01 min voltage MG5_HVBAT_CMU01_MINVOLT

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing for 2020, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2020, 2024 to 2026. Supported for 2021. Not supported for 2022 to 2023.

Modules › 02

HV battery module 02 max temperature MG5_HVBAT_CMU02_MAXTEMPConfirmed

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x81 = 129 → 1292−40 = 24.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 02 max voltage MG5_HVBAT_CMU02_MAXVOLTConfirmed

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1291 = 4753 → 47532000+1 = 3.3765 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 02 min temperature MG5_HVBAT_CMU02_MINTEMPConfirmed

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x81 = 129 → 1292−40 = 24.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 02 min voltage MG5_HVBAT_CMU02_MINVOLTConfirmed

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x125A = 4698 → 46982000+1 = 3.349 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 03

HV battery module 03 max temperature MG5_HVBAT_CMU03_MAXTEMPConfirmed

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x84 = 132 → 1322−40 = 26 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 03 max voltage MG5_HVBAT_CMU03_MAXVOLTConfirmed

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1297 = 4759 → 47592000+1 = 3.3795 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 03 min temperature MG5_HVBAT_CMU03_MINTEMPConfirmed

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x84 = 132 → 1322−40 = 26 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 03 min voltage MG5_HVBAT_CMU03_MINVOLTConfirmed

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x127D = 4733 → 47332000+1 = 3.3665 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 04

HV battery module 04 max temperature MG5_HVBAT_CMU04_MAXTEMPConfirmed

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 04 max voltage MG5_HVBAT_CMU04_MAXVOLTConfirmed

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1271 = 4721 → 47212000+1 = 3.3605 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 04 min temperature MG5_HVBAT_CMU04_MINTEMPConfirmed

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 04 min voltage MG5_HVBAT_CMU04_MINVOLTConfirmed

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1246 = 4678 → 46782000+1 = 3.339 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 05

HV battery module 05 max temperature MG5_HVBAT_CMU05_MAXTEMPConfirmed

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 05 max voltage MG5_HVBAT_CMU05_MAXVOLTConfirmed

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1262 = 4706 → 47062000+1 = 3.353 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 05 min temperature MG5_HVBAT_CMU05_MINTEMPConfirmed

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 05 min voltage MG5_HVBAT_CMU05_MINVOLTConfirmed

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x121F = 4639 → 46392000+1 = 3.3195 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 06

HV battery module 06 max temperature MG5_HVBAT_CMU06_MAXTEMPConfirmed

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7F = 127 → 1272−40 = 23.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 06 max voltage MG5_HVBAT_CMU06_MAXVOLTConfirmed

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x128F = 4751 → 47512000+1 = 3.3755 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 06 min temperature MG5_HVBAT_CMU06_MINTEMPConfirmed

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7F = 127 → 1272−40 = 23.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 06 min voltage MG5_HVBAT_CMU06_MINVOLTConfirmed

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1234 = 4660 → 46602000+1 = 3.33 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 07

HV battery module 07 max temperature MG5_HVBAT_CMU07_MAXTEMPConfirmed

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x80 = 128 → 1282−40 = 24 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 07 max voltage MG5_HVBAT_CMU07_MAXVOLTConfirmed

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1273 = 4723 → 47232000+1 = 3.3615 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 07 min temperature MG5_HVBAT_CMU07_MINTEMPConfirmed

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x80 = 128 → 1282−40 = 24 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 07 min voltage MG5_HVBAT_CMU07_MINVOLTConfirmed

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x123C = 4668 → 46682000+1 = 3.334 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 08

HV battery module 08 max temperature MG5_HVBAT_CMU08_MAXTEMPConfirmed

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x80 = 128 → 1282−40 = 24 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 08 max voltage MG5_HVBAT_CMU08_MAXVOLTConfirmed

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126F = 4719 → 47192000+1 = 3.3595 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 08 min temperature MG5_HVBAT_CMU08_MINTEMPConfirmed

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x80 = 128 → 1282−40 = 24 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 08 min voltage MG5_HVBAT_CMU08_MINVOLTConfirmed

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x123D = 4669 → 46692000+1 = 3.3345 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 09

HV battery module 09 max temperature MG5_HVBAT_CMU09_MAXTEMPConfirmed

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 09 max voltage MG5_HVBAT_CMU09_MAXVOLTConfirmed

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x128B = 4747 → 47472000+1 = 3.3735 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 09 min temperature MG5_HVBAT_CMU09_MINTEMPConfirmed

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 09 min voltage MG5_HVBAT_CMU09_MINVOLTConfirmed

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1258 = 4696 → 46962000+1 = 3.348 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 10

HV battery module 10 max temperature MG5_HVBAT_CMU10_MAXTEMPConfirmed

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7F = 127 → 1272−40 = 23.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 10 max voltage MG5_HVBAT_CMU10_MAXVOLTConfirmed

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1282 = 4738 → 47382000+1 = 3.369 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 10 min temperature MG5_HVBAT_CMU10_MINTEMPConfirmed

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7F = 127 → 1272−40 = 23.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 10 min voltage MG5_HVBAT_CMU10_MINVOLTConfirmed

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1249 = 4681 → 46812000+1 = 3.3405 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 11

HV battery module 11 max temperature MG5_HVBAT_CMU11_MAXTEMPConfirmed

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 11 max voltage MG5_HVBAT_CMU11_MAXVOLTConfirmed

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1264 = 4708 → 47082000+1 = 3.354 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 11 min temperature MG5_HVBAT_CMU11_MINTEMPConfirmed

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x83 = 131 → 1312−40 = 25.5 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 11 min voltage MG5_HVBAT_CMU11_MINVOLTConfirmed

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x122D = 4653 → 46532000+1 = 3.3265 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 12

HV battery module 12 max temperature MG5_HVBAT_CMU12_MAXTEMPConfirmed

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 12 max voltage MG5_HVBAT_CMU12_MAXVOLTConfirmed

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1270 = 4720 → 47202000+1 = 3.36 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 12 min temperature MG5_HVBAT_CMU12_MINTEMPConfirmed

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 12 min voltage MG5_HVBAT_CMU12_MINVOLTConfirmed

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1246 = 4678 → 46782000+1 = 3.339 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 13

HV battery module 13 max temperature MG5_HVBAT_CMU13_MAXTEMPConfirmed

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 13 max voltage MG5_HVBAT_CMU13_MAXVOLTConfirmed

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1279 = 4729 → 47292000+1 = 3.3645 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 13 min temperature MG5_HVBAT_CMU13_MINTEMPConfirmed

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 13 min voltage MG5_HVBAT_CMU13_MINVOLTConfirmed

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x123D = 4669 → 46692000+1 = 3.3345 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 14

HV battery module 14 max temperature MG5_HVBAT_CMU14_MAXTEMPConfirmed

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 14 max voltage MG5_HVBAT_CMU14_MAXVOLTConfirmed

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1292 = 4754 → 47542000+1 = 3.377 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 14 min temperature MG5_HVBAT_CMU14_MINTEMPConfirmed

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 14 min voltage MG5_HVBAT_CMU14_MINVOLTConfirmed

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126A = 4714 → 47142000+1 = 3.357 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 15

HV battery module 15 max temperature MG5_HVBAT_CMU15_MAXTEMPConfirmed

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 15 max voltage MG5_HVBAT_CMU15_MAXVOLTConfirmed

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1287 = 4743 → 47432000+1 = 3.3715 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 15 min temperature MG5_HVBAT_CMU15_MINTEMPConfirmed

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 15 min voltage MG5_HVBAT_CMU15_MINVOLTConfirmed

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1264 = 4708 → 47082000+1 = 3.354 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 16

HV battery module 16 max temperature MG5_HVBAT_CMU16_MAXTEMPConfirmed

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 16 max voltage MG5_HVBAT_CMU16_MAXVOLTConfirmed

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x127C = 4732 → 47322000+1 = 3.366 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 16 min temperature MG5_HVBAT_CMU16_MINTEMPConfirmed

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 16 min voltage MG5_HVBAT_CMU16_MINVOLTConfirmed

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1250 = 4688 → 46882000+1 = 3.344 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 17

HV battery module 17 max temperature MG5_HVBAT_CMU17_MAXTEMPConfirmed

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 17 max voltage MG5_HVBAT_CMU17_MAXVOLTConfirmed

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x129C = 4764 → 47642000+1 = 3.382 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 17 min temperature MG5_HVBAT_CMU17_MINTEMPConfirmed

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 17 min voltage MG5_HVBAT_CMU17_MINVOLTConfirmed

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126C = 4716 → 47162000+1 = 3.358 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 18

HV battery module 18 max temperature MG5_HVBAT_CMU18_MAXTEMPConfirmed

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 18 max voltage MG5_HVBAT_CMU18_MAXVOLTConfirmed

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1278 = 4728 → 47282000+1 = 3.364 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 18 min temperature MG5_HVBAT_CMU18_MINTEMPConfirmed

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 18 min voltage MG5_HVBAT_CMU18_MINVOLTConfirmed

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1243 = 4675 → 46752000+1 = 3.3375 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 19

HV battery module 19 max temperature MG5_HVBAT_CMU19_MAXTEMPConfirmed

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 19 max voltage MG5_HVBAT_CMU19_MAXVOLTConfirmed

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1292 = 4754 → 47542000+1 = 3.377 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 19 min temperature MG5_HVBAT_CMU19_MINTEMPConfirmed

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 19 min voltage MG5_HVBAT_CMU19_MINVOLTConfirmed

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x125F = 4703 → 47032000+1 = 3.3515 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 20

HV battery module 20 max temperature MG5_HVBAT_CMU20_MAXTEMPConfirmed

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 20 max voltage MG5_HVBAT_CMU20_MAXVOLTConfirmed

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126F = 4719 → 47192000+1 = 3.3595 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 20 min temperature MG5_HVBAT_CMU20_MINTEMPConfirmed

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 20 min voltage MG5_HVBAT_CMU20_MINVOLTConfirmed

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x124A = 4682 → 46822000+1 = 3.341 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 21

HV battery module 21 max temperature MG5_HVBAT_CMU21_MAXTEMPConfirmed

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 21 max voltage MG5_HVBAT_CMU21_MAXVOLTConfirmed

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1291 = 4753 → 47532000+1 = 3.3765 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 21 min temperature MG5_HVBAT_CMU21_MINTEMPConfirmed

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 21 min voltage MG5_HVBAT_CMU21_MINVOLTConfirmed

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1267 = 4711 → 47112000+1 = 3.3555 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 22

HV battery module 22 max temperature MG5_HVBAT_CMU22_MAXTEMPConfirmed

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 22 max voltage MG5_HVBAT_CMU22_MAXVOLTConfirmed

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1298 = 4760 → 47602000+1 = 3.38 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 22 min temperature MG5_HVBAT_CMU22_MINTEMPConfirmed

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 22 min voltage MG5_HVBAT_CMU22_MINVOLTConfirmed

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126C = 4716 → 47162000+1 = 3.358 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 23

HV battery module 23 max temperature MG5_HVBAT_CMU23_MAXTEMPConfirmed

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 23 max voltage MG5_HVBAT_CMU23_MAXVOLTConfirmed

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1279 = 4729 → 47292000+1 = 3.3645 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 23 min temperature MG5_HVBAT_CMU23_MINTEMPConfirmed

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 23 min voltage MG5_HVBAT_CMU23_MINVOLTConfirmed

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x1243 = 4675 → 46752000+1 = 3.3375 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Modules › 24

HV battery module 24 max temperature MG5_HVBAT_CMU24_MAXTEMPConfirmed

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 24 max voltage MG5_HVBAT_CMU24_MAXVOLTConfirmed

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x126F = 4719 → 47192000+1 = 3.3595 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 24 min temperature MG5_HVBAT_CMU24_MINTEMPConfirmed

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

0x7E = 126 → 1262−40 = 23 °C

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

HV battery module 24 min voltage MG5_HVBAT_CMU24_MINVOLTConfirmed

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

0x123E = 4670 → 46702000+1 = 3.335 V

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

ECU

Vehicle gateway status MG5_GWM_STATUSConfirmed

  • Service 22DID D001
  • Module710 → 718
  • Every4 s
  • Testing for 2020, 2024 to 2026

Example reply from a 2023 MG MG5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Engine

Engine oil pressure MG5_EOP

  • Service 22DID B036
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×22910000
Range
0 to 1500.7515 kPa
Unit
kPa

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Engine oil temperature MG5_EO_T

  • Service 22DID B034
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Misfires, cylinder 1 MG5_MISFIRES_C1

  • Service 22DID B143
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Misfires, cylinder 2 MG5_MISFIRES_C2

  • Service 22DID B144
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Misfires, cylinder 3 MG5_MISFIRES_C3

  • Service 22DID B145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Misfires, cylinder 4 MG5_MISFIRES_C4

  • Service 22DID B146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Transmission fluid temperature, ECU 10472701 and 11194479 MG5_ATF_T_ECU_10472701_11194479

  • Service 22DID B423
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Transmission fluid temperature, ECU 10513229 MG5_ATF_T_ECU_10513229

  • Service 22DID 1940
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Fuel

Fuel tank level MG5_FUEL_TANK_LEVEL

  • Service 22DID B043
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2020 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Trips

Odometer MG5_GWM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B921
  • Module710 → 718
  • Every1 s
  • Testing for 2020, 2024 to 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2021 to 2023. In testing for 2020, 2024 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.