SAE J1979

Parameters

The SAE J1979 standard has 1,091 parameters.

How to read a parameter card

Battery capacity calculation BCAP_R

  • Service 01PID D8
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
0Not ready
1Ready
  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery capacity calculation BCAP_R

  • Service 01PID D8
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
0Not ready
1Ready

Control module voltage VPWR

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Distance since state of health update HEALTH_DIST

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODE

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode
3Not PSA

Fuel cell current over the last second FC_CUMUL_CURR

Charge over the last second, 0.02 mAh/s per bit, shown as average current.

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val×721000
Range
0 to 4718.52 A
Unit
A

Fuel cell fuel consumption FC_FUEL_RATE

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675 g/s
Unit
g/s

Fuel cell power over the last second FC_CUMUL_ENER

Energy over the last second, 0.0001 Wh/s per bit, shown as average power.

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 87 of the reply, 32 bits.

Formula
val×36100000
Range
0 to 1546188.226 kW
Unit
kW

Fuel cell system voltage FC_VOLT

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery active time since cell balancing HEV_BATT_BAL_TIME

  • Service 01PID B8
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

HV battery actual charge rate HVESS_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery average cell temperature HEV_BATT_AVG_CELL_T

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery bus bar temperature HEV_BATT_BUS_BAR_T

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery calculated usable energy CALCULATED_ESS_CAP

  • Service 01PID D9
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

HV battery charging limit HVESS_CHARGE_LIM

  • Service 01PID D1
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery charging power HVESS_CHARGE_ACT

  • Service 01PID D1
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery continuous charge current limit HEV_BATT_CHG_I_LIM

  • Service 01PID BA
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

HV battery continuous discharge current limit HEV_BATT_DCHG_I_LIM

  • Service 01PID BA
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

HV battery continuous rated power available HEV_BATT_PWR_AVAIL

  • Service 01PID BA
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

HV battery coolant temperature HEV_BATT_COOLANT_T

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery cumulative energy in HVESS_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery cumulative energy out HVESS_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery current HVESS_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery current over the last second HVESS_CURR

Charge over the last second, 0.000001 Ah/s per bit, shown as average current. Positive is charging.

  • Service 01PID DA
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×3610000
Range
-7730941.133 to 7730941.129 A
Unit
A

HV battery discharge energy capacity HVESS_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 31 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery initial reserve energy INIT_ESS_RSRV_CAP

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kWh
Unit
kWh

HV battery maximum cell temperature HEV_BATT_MAX_CELL_T

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery maximum cell voltage HEV_BATT_MAX_CELL_V

  • Service 01PID B9
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

HV battery minimum cell temperature HEV_BATT_MIN_CELL_T

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery minimum cell voltage HEV_BATT_MIN_CELL_V

  • Service 01PID B9
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

HV battery pack A actual charge rate HVESPA_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack A cumulative energy in HVESPA_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack A cumulative energy out HVESPA_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack A current HVESPA_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack A discharge energy capacity HVESPA_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 55 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack A recommended maximum state of charge HVESPA_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack A recommended minimum state of charge HVESPA_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack A state of health HVESPA_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack A temperature HVESPA_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack A total energy throughput HVESPA_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack A voltage HVESPA_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack B actual charge rate HVESPB_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack B cumulative energy in HVESPB_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack B cumulative energy out HVESPB_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack B current HVESPB_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack B discharge energy capacity HVESPB_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 56 to 79 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack B recommended maximum state of charge HVESPB_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack B recommended minimum state of charge HVESPB_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack B state of health HVESPB_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack B temperature HVESPB_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack B total energy throughput HVESPB_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack B voltage HVESPB_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack C actual charge rate HVESPC_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack C cumulative energy in HVESPC_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack C cumulative energy out HVESPC_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack C current HVESPC_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack C discharge energy capacity HVESPC_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 80 to 103 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack C recommended maximum state of charge HVESPC_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack C recommended minimum state of charge HVESPC_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack C state of health HVESPC_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack C temperature HVESPC_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack C total energy throughput HVESPC_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack C voltage HVESPC_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack D actual charge rate HVESPD_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack D cumulative energy in HVESPD_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack D cumulative energy out HVESPD_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack D current HVESPD_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack D discharge energy capacity HVESPD_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 104 to 127 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack D recommended maximum state of charge HVESPD_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack D recommended minimum state of charge HVESPD_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack D state of health HVESPD_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 47 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack D temperature HVESPD_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack D total energy throughput HVESPD_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack D voltage HVESPD_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack E actual charge rate HVESPE_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack E cumulative energy in HVESPE_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack E cumulative energy out HVESPE_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack E current HVESPE_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack E discharge energy capacity HVESPE_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 128 to 151 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack E recommended maximum state of charge HVESPE_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack E recommended minimum state of charge HVESPE_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack E state of health HVESPE_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 48 to 55 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack E temperature HVESPE_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack E total energy throughput HVESPE_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack E voltage HVESPE_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack F actual charge rate HVESPF_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack F cumulative energy in HVESPF_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack F cumulative energy out HVESPF_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack F current HVESPF_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack F discharge energy capacity HVESPF_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 152 to 175 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack F recommended maximum state of charge HVESPF_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack F recommended minimum state of charge HVESPF_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack F state of health HVESPF_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 56 to 63 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack F temperature HVESPF_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack F total energy throughput HVESPF_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack F voltage HVESPF_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack G actual charge rate HVESPG_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack G cumulative energy in HVESPG_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack G cumulative energy out HVESPG_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack G current HVESPG_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack G discharge energy capacity HVESPG_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 176 to 199 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack G recommended maximum state of charge HVESPG_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack G recommended minimum state of charge HVESPG_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack G state of health HVESPG_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 64 to 71 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack G temperature HVESPG_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack G total energy throughput HVESPG_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack G voltage HVESPG_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery pack H actual charge rate HVESPH_ACR

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bits 136 to 151 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV battery pack H cumulative energy in HVESPH_Enrg_In

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack H cumulative energy out HVESPH_Enrg_Out

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

HV battery pack H current HVESPH_Cur

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bits 136 to 151 of the reply, 16 bits.

Formula
val20−1600
Range
-1600 to 1676.75 A
Unit
A

HV battery pack H discharge energy capacity HVESPH_DEnrg_CAP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bits 200 to 223 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

HV battery pack H recommended maximum state of charge HVESPH_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 136 to 151 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack H recommended minimum state of charge HVESPH_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 136 to 151 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery pack H state of health HVESPH_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 72 to 79 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery pack H temperature HVESPH_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery pack H total energy throughput HVESPH_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery pack H voltage HVESPH_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 136 to 151 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

HV battery power over the last second HVESS_ENER

Energy over the last second, 0.000001 Wh/s per bit, shown as average power. Positive is charging.

  • Service 01PID D4
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×3610000000
Range
-7730.941133 to 7730.941129 kW
Unit
kW

HV battery recommended maximum state of charge HVESS_MAX_SOC

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery recommended minimum state of charge HVESS_MIN_SOC

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val640
Range
0 to 102.3984375 %
Unit
%

HV battery remaining reserve energy REMAINING_ESS_RSRV_CAP

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kWh
Unit
kWh

HV battery state of health HVESS_SOH

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

HV battery temperature HVESS_Temp

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV battery thermal state HEV_BATT_THERM_MODE

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bits 48 to 55 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffThermal system off
1Active cooling
2Passive cooling
3Active heating
4Passive heating

HV battery total energy throughput HVESS_Enrg_Tput

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

HV battery voltage HVESS_Volt

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 V
Unit
V

Hybrid battery pack remaining charge BAT_SOC

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Hybrid/EV Battery System Current HEV_BATT_A

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Hybrid/EV Battery System Voltage HEV_BATT_V

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.98 V
Unit
V

Hybrid/EV Vehicle Charging State HEV_MODE

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

State of certified energy SOCE

Estimation of the battery's certified usable energy.

Pelican can show this parameter as the state of health.

  • Service 01PID D2
  • Module7E0 → 7E8
  • Every300 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

State of certified energy supported SOCE_SUP

  • Service 01PID D2
  • Module7E0 → 7E8
  • Every300 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

State of certified range SOCR

Estimation of the battery's certified usable range. This is a best-effort representation of the degradation of components that contribute to the range of the vehicle.

Pelican can show this parameter as the state of health.

  • Service 01PID D2
  • Module7E0 → 7E8
  • Every300 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

State of certified range supported SOCR_SUP

  • Service 01PID D2
  • Module7E0 → 7E8
  • Every300 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Traction battery pack State of Health BAT_SOH

  • Service 01PID B2
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Internal

Distance since state of health update supported HEALTH_DIST_SUP

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUP

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel cell current supported FC_CUMUL_CURR_SUP

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel cell energy supported FC_CUMUL_ENER_SUP

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel cell fuel consumption supported FC_FUEL_RATE_SUP

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel cell system voltage supported FC_VOLT_SUP

  • Service 01PID D5
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery average cell temperature supported HEV_BATT_AVG_CELL_T_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery bus bar temperature supported HEV_BATT_BUS_BAR_T_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery coolant temperature supported HEV_BATT_COOLANT_T_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery maximum cell temperature supported HEV_BATT_MAX_CELL_T_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery minimum cell temperature supported HEV_BATT_MIN_CELL_T_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A actual charge rate supported HVESPA_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A cumulative energy in supported HVESPA_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A cumulative energy out supported HVESPA_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A current supported HVESPA_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A discharge energy capacity supported HVESPA_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A recommended maximum state of charge supported HVESPA_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A recommended minimum state of charge supported HVESPA_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A state of health supported HVESPA_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A temperature supported HVESPA_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A total energy throughput supported HVESPA_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack A voltage supported HVESPA_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B actual charge rate supported HVESPB_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B cumulative energy in supported HVESPB_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B cumulative energy out supported HVESPB_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B current supported HVESPB_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B discharge energy capacity supported HVESPB_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B recommended maximum state of charge supported HVESPB_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B recommended minimum state of charge supported HVESPB_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B state of health supported HVESPB_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B temperature supported HVESPB_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B total energy throughput supported HVESPB_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack B voltage supported HVESPB_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C actual charge rate supported HVESPC_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C cumulative energy in supported HVESPC_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C cumulative energy out supported HVESPC_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C current supported HVESPC_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C discharge energy capacity supported HVESPC_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C recommended maximum state of charge supported HVESPC_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C recommended minimum state of charge supported HVESPC_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C state of health supported HVESPC_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C temperature supported HVESPC_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C total energy throughput supported HVESPC_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack C voltage supported HVESPC_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D actual charge rate supported HVESPD_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D cumulative energy in supported HVESPD_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D cumulative energy out supported HVESPD_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D current supported HVESPD_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D discharge energy capacity supported HVESPD_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D recommended maximum state of charge supported HVESPD_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D recommended minimum state of charge supported HVESPD_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D state of health supported HVESPD_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D temperature supported HVESPD_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D total energy throughput supported HVESPD_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack D voltage supported HVESPD_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E actual charge rate supported HVESPE_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E cumulative energy in supported HVESPE_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E cumulative energy out supported HVESPE_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E current supported HVESPE_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E discharge energy capacity supported HVESPE_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E recommended maximum state of charge supported HVESPE_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E recommended minimum state of charge supported HVESPE_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E state of health supported HVESPE_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E temperature supported HVESPE_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E total energy throughput supported HVESPE_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack E voltage supported HVESPE_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F actual charge rate supported HVESPF_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F cumulative energy in supported HVESPF_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F cumulative energy out supported HVESPF_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F current supported HVESPF_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F discharge energy capacity supported HVESPF_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F recommended maximum state of charge supported HVESPF_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F recommended minimum state of charge supported HVESPF_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F state of health supported HVESPF_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F temperature supported HVESPF_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F total energy throughput supported HVESPF_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack F voltage supported HVESPF_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G actual charge rate supported HVESPG_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G cumulative energy in supported HVESPG_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G cumulative energy out supported HVESPG_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G current supported HVESPG_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G discharge energy capacity supported HVESPG_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G recommended maximum state of charge supported HVESPG_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G recommended minimum state of charge supported HVESPG_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G state of health supported HVESPG_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G temperature supported HVESPG_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G total energy throughput supported HVESPG_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack G voltage supported HVESPG_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H actual charge rate supported HVESPH_ACR_SUP

  • Service 01PID B3
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H cumulative energy in supported HVESPH_Enrg_In_SUP

  • Service 01PID BB
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H cumulative energy out supported HVESPH_Enrg_Out_SUP

  • Service 01PID BC
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H current supported HVESPH_Cur_SUP

  • Service 01PID B5
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H discharge energy capacity supported HVESPH_DEnrg_CAP_SUP

  • Service 01PID C2
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H recommended maximum state of charge supported HVESPH_MAX_SOC_SUP

  • Service 01PID C1
  • Module7E0 → 7E8
  • Every30 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H recommended minimum state of charge supported HVESPH_MIN_SOC_SUP

  • Service 01PID BF
  • Module7E0 → 7E8
  • Every30 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H state of health supported HVESPH_SOH_SUP

  • Service 01PID BE
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H temperature supported HVESPH_Temp_SUP

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every5 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H total energy throughput supported HVESPH_Enrg_Tput_SUP

  • Service 01PID BD
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery pack H voltage supported HVESPH_Volt_SUP

  • Service 01PID B6
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

HV battery thermal state supported HEV_BATT_THERM_MODE_SUP

  • Service 01PID B7
  • Module7E0 → 7E8
  • Every5 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hybrid/EV Battery Current supported? HEV_BATT_A_SUP

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUP

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUP

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Initial reserve energy supported INIT_ESS_RSRV_CAP_SUP

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Remaining reserve energy supported REMAINING_ESS_RSRV_CAP_SUP

  • Service 01PID D0
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Climate

Ambient air temperature AAT

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Clocks

Time since engine start RUNTM

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Control

Absolute throttle position TP

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Absolute throttle position B TP_B

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Absolute throttle position C TP_C

Pelican can show this parameter as the throttle position.

  • Service 01PID 48
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Relative throttle position TP_R

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Pedals

Accelerator pedal position (relative) APP_R

  • Service 01PID 5A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Accelerator pedal position D APP_D

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Accelerator pedal position E APP_E

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Accelerator pedal position F APP_F

  • Service 01PID 4B
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

DTCs

Cumulative engine hours with the continuous MI active MI_TIME_CUM

  • Service 01PID 93
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Distance traveled since diagnostic trouble codes cleared CLR_DIST

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance traveled while MIL was activated MIL_DIST

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

DTC that caused required freeze frame data storage DTCFRZF

0 indicates no freeze frame data.

  • Service 01PID 02
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Hexadecimal

ECU engine hours with the continuous MI active OBD_MI_TIME

  • Service 01PID 91
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

ECU malfunction indicator status MI_MODE_ECU

  • Service 01PID 91
  • Module7E0 → 7E8
  • Every1 s

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffMI activation mode 1, MI off
1On demandMI activation mode 2, on-demand MI
2ShortMI activation mode 3, short MI
3ContinuousMI activation mode 4, continuous MI
14Error
15Not availableNot available or not required of this ECU

Emission system readiness VOBD_RDY

  • Service 01PID 90
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CompleteAll vehicle emission system monitors complete
1Not completeNot all vehicle emission system monitors complete

Engine hours with the continuous MI active VOBD_MI_TIME

  • Service 01PID 90
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine run time since diagnostic trouble codes cleared CLR_TIME

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Highest ECU class B1 malfunction counter OBD_B1_TIME

  • Service 01PID 91
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Malfunction indicator lamp MIL

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

MI display strategy MI_DISP_VOBD

  • Service 01PID 90
  • Module7E0 → 7E8
  • Every1 s

Bits 6 to 7 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0Non-discriminatoryAll ECUs employ a non-discriminatory MI display strategy
1DiscriminatoryAll ECUs employ a discriminatory MI display strategy
3Not availableNot available or not required of this vehicle

Number of DTCs stored in this ECU DTC_CNT

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Number of warm-ups since diagnostic trouble codes cleared WARM_UPS

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Propulsion system active trips since DTCs cleared NUMPSATRIPSFLTMEMCLR

  • Service 01PID D6
  • Module7E0 → 7E8
  • Every30 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Time run by the engine while MIL was activated MIL_TIME

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Vehicle malfunction indicator status MI_MODE_VOBD

  • Service 01PID 90
  • Module7E0 → 7E8
  • Every1 s

Bits 2 to 5 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffMI activation mode 1, MI off
1On demandMI activation mode 2, on-demand MI
2ShortMI activation mode 3, short MI
3ContinuousMI activation mode 4, continuous MI
14Error
15Not availableNot available or not required of this vehicle

Status

A/C system refrigerant monitoring ACRF_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

A/C system refrigerant monitoring completed ACRFCMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

A/C system refrigerant monitoring ready ACRF_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Catalyst monitoring CAT_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst monitoring completed CAT_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Catalyst monitoring ready CAT_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Comprehensive component monitoring completed CCM_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Comprehensive component monitoring ready CCM_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

EGR system monitoring EGR_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR system monitoring completed EGR_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

EGR system monitoring ready EGR_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Evaporative system monitoring EVAP_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evaporative system monitoring completed EVAPCMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Evaporative system monitoring ready EVAP_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Fuel system monitoring completed FUEL_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Fuel system monitoring ready FUEL_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Heated catalyst monitoring HCAT_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Heated catalyst monitoring completed HCATCMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Heated catalyst monitoring ready HCAT_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Misfire monitoring completed MIS_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Misfire monitoring ready MIS_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Oxygen sensor heater monitoring HTR_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Oxygen sensor heater monitoring completed HTR_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Oxygen sensor heater monitoring ready HTR_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Oxygen sensor monitoring O2S_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Oxygen sensor monitoring completed O2S_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Oxygen sensor monitoring ready O2S_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Secondary air system monitoring AIR_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Secondary air system monitoring completed AIR_CMPL

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Secondary air system monitoring ready AIR_RDY

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Support

A/C system refrigerant monitoring supported ACRF_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst monitoring supported CAT_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Comprehensive component monitoring enabled CCM_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Comprehensive component monitoring supported CCM_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Compression ignition monitoring supported CIM_SUP

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Compression ignition monitoring supported CIM_SUP_FLAG

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

EGR system monitoring supported EGR_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evaporative system monitoring supported EVAP_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system monitoring enabled FUEL_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system monitoring supported FUEL_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Heated catalyst monitoring supported HCAT_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Misfire monitoring enabled MIS_ENA

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Misfire monitoring supported MIS_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Oxygen sensor heater monitoring supported HTR_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Oxygen sensor monitoring supported O2S_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Secondary air system monitoring supported AIR_SUP

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Emissions

Actual SCR catalyst A NH3 storage SCR_NH3_ACT_A

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/L
Unit
g/L

Actual SCR catalyst B NH3 storage SCR_NH3_ACT_B

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/L
Unit
g/L

Aftertreatment fuel pressure AFT_FP

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

Average demanded reagent consumption REAG_DEMD

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 L/h
Unit
L/h

Average distance between particulate filter regens PF_REGEN_AVGD

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Average reagent consumption REAG_RATE

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 L/h
Unit
L/h

Average time between particulate filter regens PF_REGEN_AVGT

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Commanded DEF dosing DEF_CMD

  • Service 01PID A5
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

Corrected NOx concentration bank 1, sensor 1 NOXC11

Parts per million.

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 1, sensor 2 NOXC12

Parts per million.

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 1, sensor 3 NOXC13

Parts per million.

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 1, sensor 4 NOXC14

Parts per million.

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 2, sensor 1 NOXC21

Parts per million.

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 2, sensor 2 NOXC22

Parts per million.

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 2, sensor 3 NOXC23

Parts per million.

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Corrected NOx concentration bank 2, sensor 4 NOXC24

Parts per million.

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

DEF concentration DEF_CON

Concentration of urea in water. 32.5% is the proper concentration.

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 %
Unit
%

DEF doser A dosing mode DEFA_MODE

0 means the dosing system is off. 1 to 253 are manufacturer-specific modes. 254 (error, not dosing) and 255 (not available) read as no value.

  • Service 01PID AC
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

DEF doser A maximum dosing rate DEFA_MAX

  • Service 01PID AC
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val×310000
Range
0 to 19.6605 kg/h
Unit
kg/h

DEF doser B commanded dosing DEFB_CMD

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

DEF doser B dosing mode DEFB_MODE

0 means the dosing system is off. 1 to 253 are manufacturer-specific modes. 254 (error, not dosing) and 255 (not available) read as no value.

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

DEF doser B maximum dosing rate DEFB_MAX

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×310000
Range
0 to 19.2765 kg/h
Unit
kg/h

DEF tank level DEF_LVL

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

DEF tank temperature DEF_T

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

DEF type DEF_TYPE

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 3 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0Urea too highUrea concentration too high
1Urea too lowUrea concentration too low
2Diesel or otherFluid is diesel or another fluid
3Proper mixtureDEF is the proper mixture
13UnknownNo concentration sensor fault, fluid type cannot be determined
14Sensor faultConcentration sensor fault, no result

DEF used in the current driving cycle DEF_UCDC

  • Service 01PID A5
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675 L
Unit
L

Distance travelled in the current 10,000 km block SCR_IND_DIST_1D

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance with SCR inducement active in the 10,000-20,000 km block SCR_IND_DIST_2N

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance with SCR inducement active in the 20,000-30,000 km block SCR_IND_DIST_3N

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance with SCR inducement active in the 30,000-40,000 km block SCR_IND_DIST_4N

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance with SCR inducement active in the current 10,000 km block SCR_IND_DIST_1N

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Emission requirements to which vehicle is designed EMIS_SUP

  • Service 01PID 5F
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEV) C
17EURO VIHeavy Duty Vehicles (Euro VI)

Engine hours with a liquid reagent injection system failure LRIS_FAILURE_TIME

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with a NOx control monitoring system fault MON_SYS_TIME

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with a particulate control monitoring system fault PCD_FAILURE_TIME

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with an impeded EGR valve EGR_TIME

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with incorrect reagent consumption REAG_CON_TIME

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with incorrect reagent quality REAG_QUAL_TIME

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with reagent dosing interrupted REAG_DOSE_TIME

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine hours with the particulate filter removed or blocked DPF_REMOVAL_BLOCKED_TIME

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

Engine-out NOx mass emission rate NOX_EO

  • Service 01PID 97
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/s
Unit
g/s

Exhaust particulate control diagnostic count EXH_PM_OCC_CNT

  • Service 01PID C4
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

Exhaust particulate control diagnostic time EXH_PM_TIME

  • Service 01PID C4
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Hydrocarbon doser flow rate HC_INJ_FL

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val1200
Range
0 to 54.6125 g/s
Unit
g/s

Hydrocarbon doser injector duty cycle HC_INJ_DC

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Inside manufacturer-specific PM NTE carve-out area PM_NTE_CARVE

  • Service 01PID 7E
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Inside PM control area PM_NTE_IN

  • Service 01PID 7E
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Level one inducement status INDUC_L1

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel one inducement inactive
1EnabledLevel one inducement enabled
2ActiveLevel one inducement active
3Not supportedLevel one inducement not supported

Level three inducement status INDUC_L3

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 9 to 10 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel three inducement inactive
1EnabledLevel three inducement enabled
2ActiveLevel three inducement active
3Not supportedLevel three inducement not supported

Level two inducement status INDUC_L2

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bits 11 to 12 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel two inducement inactive
1EnabledLevel two inducement enabled
2ActiveLevel two inducement active
3Not supportedLevel two inducement not supported

Normalized trigger for particulate filter regen PF_REGEN_PCT

0% means the filter is clean and a regen just finished. 100% means the filter is ready to regenerate.

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

NOx adsorber desulfurization in progress NOX_ADS_DESULF

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx adsorber regen in progress NOX_ADS_REGEN

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx concentration bank 1, sensor 1 NOX11

Parts per million.

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 1, sensor 2 NOX12

Parts per million.

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 1, sensor 3 NOX13

Parts per million.

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 1, sensor 4 NOX14

Parts per million.

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 2, sensor 1 NOX21

Parts per million.

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 2, sensor 2 NOX22

Parts per million.

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 2, sensor 3 NOX23

Parts per million.

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx concentration bank 2, sensor 4 NOX24

Parts per million.

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

NOx control (NCD) warning lamp NCD_WL

  • Service 01PID C8
  • Module7E0 → 7E8
  • Every1 s

Bits 4 to 5 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffWarning lamp off
1OnWarning lamp continuously on
2BlinkWarning lamp blinking
3Not usedNot utilized

NOx warning system active NOX_WARN_ACT

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NTE deficiency for PM active area PM_NTE_DEF

  • Service 01PID 7E
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Outside PM control area PM_NTE_OUT

  • Service 01PID 7E
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate control (PCD) warning lamp PCD_WL

  • Service 01PID C8
  • Module7E0 → 7E8
  • Every1 s

Bits 2 to 3 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffWarning lamp off
1OnWarning lamp continuously on
2BlinkWarning lamp blinking
3Not usedNot utilized

Particulate filter regen in progress PF_REGEN_STAT

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter regen type PF_REGEN_TYPE

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0PassivePassive regen
1ActiveActive regen

Particulate level one inducement status PM_INDUC_L1

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel one inducement inactive
1EnabledLevel one inducement enabled
2ActiveLevel one inducement active
3Not supportedLevel one inducement not supported

Particulate level three inducement status PM_INDUC_L3

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 9 to 10 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel three inducement inactive
1EnabledLevel three inducement enabled
2ActiveLevel three inducement active
3Not supportedLevel three inducement not supported

Particulate level two inducement status PM_INDUC_L2

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bits 11 to 12 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0InactiveLevel two inducement inactive
1EnabledLevel two inducement enabled
2ActiveLevel two inducement active
3Not supportedLevel two inducement not supported

Particulate warning system active PM_WARN_ACT

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM mass concentration bank 1, sensor 1 PM11

Milligrams per cubic meter.

  • Service 01PID 86
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val80
Range
0 to 819.1875
Unit
Number

PM mass concentration bank 2, sensor 1 PM21

Milligrams per cubic meter.

  • Service 01PID 86
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val80
Range
0 to 819.1875
Unit
Number

PM sensor bank 1, sensor 1 measuring PM11_ACTIVE

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 1, sensor 1 regenerating PM11_REGEN

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 2, sensor 1 measuring PM21_ACTIVE

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 39 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 2, sensor 1 regenerating PM21_REGEN

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor normalized output bank 1, sensor 1 PM11_OUT

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 %
Unit
%

PM sensor normalized output bank 2, sensor 1 PM21_OUT

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 %
Unit
%

Reagent tank level REAG_LVL

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Run time with NOx warning active NWI_TIME

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bits 48 to 79 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

SCR inducement for incorrect reagent SCR_IND_INCORR_REAG

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for incorrect reagent in the 0-10,000 km history block SCR_IND_INCORR_REAG1

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for incorrect reagent in the 10,000-20,000 km history block SCR_IND_INCORR_REAG2

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for incorrect reagent in the 20,000-30,000 km history block SCR_IND_INCORR_REAG3

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for incorrect reagent in the 30,000-40,000 km history block SCR_IND_INCORR_REAG4

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for NOx emissions too high SCR_IND_NOX_LEVEL

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for NOx emissions too high in the 0-10,000 km history block SCR_IND_NOX_LEVEL1

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for NOx emissions too high in the 10,000-20,000 km history block SCR_IND_NOX_LEVEL2

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for NOx emissions too high in the 20,000-30,000 km history block SCR_IND_NOX_LEVEL3

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for NOx emissions too high in the 30,000-40,000 km history block SCR_IND_NOX_LEVEL4

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent consumption deviation SCR_IND_CONSUMP_DEVIATION

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent consumption deviation in the 0-10,000 km history block SCR_IND_CONSUMP_DEVIATION1

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent consumption deviation in the 10,000-20,000 km history block SCR_IND_CONSUMP_DEVIATION2

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent consumption deviation in the 20,000-30,000 km history block SCR_IND_CONSUMP_DEVIATION3

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent consumption deviation in the 30,000-40,000 km history block SCR_IND_CONSUMP_DEVIATION4

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent level too low SCR_IND_LEVEL_LOW

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent level too low in the 0-10,000 km history block SCR_IND_LEVEL_LOW1

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent level too low in the 10,000-20,000 km history block SCR_IND_LEVEL_LOW2

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent level too low in the 20,000-30,000 km history block SCR_IND_LEVEL_LOW3

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement for reagent level too low in the 30,000-40,000 km history block SCR_IND_LEVEL_LOW4

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

SCR inducement system active SCR_IND_ACTIVE

  • Service 01PID 88
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Shared NCD and PCD warning lamp NCD_PCD_WL

Used only when one lamp serves both the NOx control and particulate control systems.

  • Service 01PID C8
  • Module7E0 → 7E8
  • Every1 s

Bits 6 to 7 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0OffWarning lamp off
1OnWarning lamp continuously on
2BlinkWarning lamp blinking
3Not usedNot utilized

Tailpipe NOx mass emission rate NOX_TP

  • Service 01PID 97
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/s
Unit
g/s

Target SCR catalyst A NH3 storage SCR_NH3_TGT_A

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/L
Unit
g/L

Target SCR catalyst B NH3 storage SCR_NH3_TGT_B

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 g/L
Unit
g/L

Engine

02S Bank 3, Sensor 1 present O2S31_EXISTS

  • Service 01PID 1D
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 3, Sensor 2 present O2S32_EXISTS

  • Service 01PID 1D
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 4, Sensor 1 present O2S41_EXISTS

  • Service 01PID 1D
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 4, Sensor 2 present O2S42_EXISTS

  • Service 01PID 1D
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Absolute evap system vapor pressure EVAP_VPA

Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 53
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kPa
Unit
kPa

Absolute load value LOAD_ABS

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Absolute Throttle Position G TP_G

Pelican can show this parameter as the throttle position.

  • Service 01PID 8D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Actual EGR A duty cycle/position EGR_A_ACT

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Actual EGR B duty cycle/position EGR_B_ACT

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Actual engine torque TQ_ACT

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Air flow rate from mass air flow sensor MAF

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Barometric pressure BARO

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Boost pressure sensor A BP_A_ACT

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Boost pressure sensor B BP_B_ACT

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Calculated engine load LOAD_PCT

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Catalyst temperature A CATEMP_A

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature B CATEMP_B

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature bank 1, sensor 1 CATEMP11

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature bank 1, sensor 2 CATEMP12

  • Service 01PID 3E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature bank 2, sensor 1 CATEMP21

  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature bank 2, sensor 2 CATEMP22

  • Service 01PID 3F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature C CATEMP_C

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Catalyst temperature D CATEMP_D

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Charge air cooler temperature bank 1, sensor 1 CACT_11

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Charge air cooler temperature bank 1, sensor 2 CACT_12

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Charge air cooler temperature bank 2, sensor 1 CACT_21

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Charge air cooler temperature bank 2, sensor 2 CACT_22

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Commanded boost pressure A BP_A_CMD

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Commanded boost pressure B BP_B_CMD

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Commanded EGR EGR_PCT

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded EGR A duty cycle/position EGR_A_CMD

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded EGR B duty cycle/position EGR_B_CMD

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded equivalence ratio EQ_RAT

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Commanded evaporative purge EVAP_PCT

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded fresh air flow AIR_FL_TGT

  • Service 01PID AF
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kg/h
Unit
kg/h

Commanded injection control pressure A ICP_A_CMD

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Commanded injection control pressure B ICP_B_CMD

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Commanded intake air flow A control IAF_A_CMD

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded intake air flow B control IAF_B_CMD

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded secondary air status AIR_STAT

  • Service 01PID 12
  • Module7E0 → 7E8
  • Every60 s

Bits 5 to 7 of the reply, 3 bits.

Unit
Named states
States
Raw valueStateMeaning
1UPSUpstream of first catalytic converter
2DNSDownstream of first catalytic converter inlet
4OFFAtmosphere / off
8DIAGPump commanded on for diagnostics

Commanded Throttle Actuator A Control TAC_A_CMD

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded Throttle Actuator B Control TAC_B_CMD

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded throttle actuator control TAC_PCT

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded variable geometry turbo A position VGT_A_CMD

0% is vanes bypassed, 100% vanes not bypassed.

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded variable geometry turbo B position VGT_B_CMD

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded wastegate A position WG_A_CMD

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Commanded wastegate B position WG_B_CMD

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Cylinder fuel rate CYL_RATE

  • Service 01PID A2
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 mg/stroke
Unit
mg/stroke

Driver's demand engine torque TQ_DD

  • Service 01PID 61
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

EGR A error EGR_A_ERR

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

EGR B error EGR_B_ERR

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

EGR error EGR_ERR

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

EGR mass flow rate A EGR_M_FL_A

  • Service 01PID B0
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kg/h
Unit
kg/h

EGR mass flow rate B EGR_M_FL_B

  • Service 01PID B0
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kg/h
Unit
kg/h

Electric motor A speed EMA_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor A torque EMA_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor B speed EMB_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor B torque EMB_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor C speed EMC_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor C torque EMC_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor D speed EMD_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor D torque EMD_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor E speed EME_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor E torque EME_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor F speed EMF_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 88 to 103 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor F torque EMF_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 88 to 103 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor G speed EMG_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor G torque EMG_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Electric motor H speed EMH_RPM

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Electric motor H torque EMH_TQ

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Engine coolant temperature ECT

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine coolant temperature 1 ECT_1

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine coolant temperature 2 ECT_2

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine Friction - Percent Torque TQ_FR

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine oil temperature EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine reference torque TQ_REF

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Engine RPM RPM

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Evap system vapor pressure EVAP_VP

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Evap system vapor pressure (wide) EVAP_VP_WIDE

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 54
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32767 to 32768 kPa
Unit
kPa

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTA

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTB

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTC

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTD

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Exhaust gas temperature bank 1, sensor 1 EGT11

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 1, sensor 2 EGT12

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 1, sensor 3 EGT13

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 1, sensor 4 EGT14

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 2, sensor 1 EGT21

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 2, sensor 2 EGT22

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 2, sensor 3 EGT23

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust gas temperature bank 2, sensor 4 EGT24

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Exhaust pressure bank 1, sensor 1 EP_11

  • Service 01PID 73
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Exhaust pressure bank 1, sensor 2 EP_12

  • Service 01PID CB
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Exhaust pressure bank 2, sensor 1 EP_21

  • Service 01PID 73
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Exhaust pressure bank 2, sensor 2 EP_22

  • Service 01PID CB
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Fuel injection timing FUEL_TIMING

Start of main fuel injection relative to Top Dead Center (TDC). Positive degrees indicate before TDC, negative degrees indicate after TDC.

  • Service 01PID 5D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−38665
Range
-210 to 301.992 °
Unit
°

Fuel pressure FP

  • Service 01PID 0A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3
Range
0 to 765 kPa
Unit
kPa

Fuel pressure relative to manifold vacuum FRP_REL

Fuel rail pressure at the engine when the reading is referenced to manifold vacuum (relative pressure).

  • Service 01PID 22
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.079
Range
0 to 5177.27 kPa
Unit
kPa

Fuel rail pressure FRP

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Fuel rail pressure (absolute) FRP_ABS

Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.

  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Injection control pressure A ICP_A

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Injection control pressure B ICP_B

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Intake air temperature IAT

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 1, sensor 1 IAT_11

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 1, sensor 2 IAT_12

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 1, sensor 3 IAT_13

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 2, sensor 1 IAT_21

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 2, sensor 2 IAT_22

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake air temperature, bank 2, sensor 3 IAT_23

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Intake manifold absolute pressure MAP

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Long term fuel trim (bank 1) LONGFT1

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Long term fuel trim (bank 2) LONGFT2

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Long term fuel trim (bank 4) LONGFT4

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2

  • Service 01PID 58
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Manifold surface temperature MST

  • Service 01PID 84
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Mass Air Flow Sensor A MAFA

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Mass Air Flow Sensor B MAFB

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Particulate filter bank 1 delta pressure DPF1_DP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 kPa
Unit
kPa

Particulate filter bank 1 inlet pressure DPF1_INP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Particulate filter bank 1 inlet temperature DPF1_INT

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Particulate filter bank 1 outlet pressure DPF1_OUTP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Particulate filter bank 1 outlet temperature DPF1_OUTT

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Particulate filter bank 2 delta pressure DPF2_DP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 kPa
Unit
kPa

Particulate filter bank 2 inlet pressure DPF2_INP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Particulate filter bank 2 inlet temperature DPF2_INT

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Particulate filter bank 2 outlet pressure DPF2_OUTP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kPa
Unit
kPa

Particulate filter bank 2 outlet temperature DPF2_OUTT

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Power take off (PTO) status PTO_STAT

  • Service 01PID 1E
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Relative intake air flow A position IAF_A_REL

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Relative intake air flow B position IAF_B_REL

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Relative Throttle A Position TP_A_REL

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Relative Throttle B Position TP_B_REL

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Short term fuel trim (bank 1) SHRTFT1

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Short term fuel trim (bank 2) SHRTFT2

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Short term fuel trim (bank 4) SHRTFT4

Correction being used by the closed-loop fuel algorithm.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1

  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Short term secondary O2 sensor fuel trim (bank 2) STSO2FT2

  • Service 01PID 57
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Timing advance SPARKADV

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Total Engine Run Time RUN_TIME

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total Idle Run Time IDLE_TIME

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #1 timer 1 active AECD1_TIME1

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #1 timer 2 active AECD1_TIME2

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #2 timer 1 active AECD2_TIME1

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #2 timer 2 active AECD2_TIME2

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #3 timer 1 active AECD3_TIME1

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #3 timer 2 active AECD3_TIME2

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #4 timer 1 active AECD4_TIME1

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #4 timer 2 active AECD4_TIME2

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #5 timer 1 active AECD5_TIME1

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #5 timer 2 active AECD5_TIME2

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bits 296 to 327 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #6 timer 1 active AECD6_TIME1

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #6 timer 2 active AECD6_TIME2

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #7 timer 1 active AECD7_TIME1

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #7 timer 2 active AECD7_TIME2

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #8 timer 1 active AECD8_TIME1

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #8 timer 2 active AECD8_TIME2

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #9 timer 1 active AECD9_TIME1

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #9 timer 2 active AECD9_TIME2

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #10 timer 1 active AECD10_TIME1

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #10 timer 2 active AECD10_TIME2

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bits 296 to 327 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #11 timer 1 active AECD11_TIME1

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #11 timer 2 active AECD11_TIME2

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #12 timer 1 active AECD12_TIME1

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #12 timer 2 active AECD12_TIME2

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #13 timer 1 active AECD13_TIME1

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #13 timer 2 active AECD13_TIME2

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #14 timer 1 active AECD14_TIME1

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #14 timer 2 active AECD14_TIME2

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #15 timer 1 active AECD15_TIME1

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #15 timer 2 active AECD15_TIME2

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bits 296 to 327 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #16 timer 1 active AECD16_TIME1

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #16 timer 2 active AECD16_TIME2

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #17 timer 1 active AECD17_TIME1

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #17 timer 2 active AECD17_TIME2

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #18 timer 1 active AECD18_TIME1

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #18 timer 2 active AECD18_TIME2

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #19 timer 1 active AECD19_TIME1

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #19 timer 2 active AECD19_TIME2

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #20 timer 1 active AECD20_TIME1

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #20 timer 2 active AECD20_TIME2

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bits 296 to 327 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #21 timer 1 active AECD21_TIME1

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #21 timer 2 active AECD21_TIME2

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #22 timer 1 active AECD22_TIME1

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #22 timer 2 active AECD22_TIME2

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #23 timer 1 active AECD23_TIME1

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #23 timer 2 active AECD23_TIME2

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #24 timer 1 active AECD24_TIME1

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #24 timer 2 active AECD24_TIME2

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #25 timer 1 active AECD25_TIME1

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 264 to 295 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total run time with EI-AECD #25 timer 2 active AECD25_TIME2

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bits 296 to 327 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Total Run Time With PTO Active PTO_TIME

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Transmission actual gear GEAR_ACT

0 is neutral, and 1 to 15 are gears. 1 can also mean reverse.

  • Service 01PID A4
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Transmission actual gear ratio GEAR_RAT

Input shaft speed over output shaft speed.

  • Service 01PID A4
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

Turbocharger A compressor inlet temperature TCA_CINT

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Turbocharger A compressor outlet temperature TCA_COUTT

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Turbocharger A speed TCA_RPM

  • Service 01PID 74
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 rpm
Unit
rpm

Turbocharger A turbine inlet temperature TCA_TINT

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Turbocharger A turbine outlet temperature TCA_TOUTT

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Turbocharger B compressor inlet temperature TCB_CINT

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Turbocharger B compressor outlet temperature TCB_COUTT

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Turbocharger B speed TCB_RPM

  • Service 01PID 74
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 rpm
Unit
rpm

Turbocharger B turbine inlet temperature TCB_TINT

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Turbocharger B turbine outlet temperature TCB_TOUTT

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Type of fuel currently being used by the vehicle FUEL_TYP

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Variable geometry turbo A control status VGT_A_STAT

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 46 to 47 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1VGT_A_OLOpen loop, no fault present
2VGT_A_CLClosed loop, no fault present
3VGT_A_FAULTFault present, VGT data unreliable

Variable geometry turbo A position VGT_A_ACT

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Variable geometry turbo B control status VGT_B_STAT

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 44 to 45 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1VGT_B_OLOpen loop, no fault present
2VGT_B_CLClosed loop, no fault present
3VGT_B_FAULTFault present, VGT data unreliable

Variable geometry turbo B position VGT_B_ACT

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Wastegate A position WG_A_ACT

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Wastegate B position WG_B_ACT

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

AuxInputs

Auto Trans Neutral Drive Status N/D_STAT

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Glow plug lamp status GPL_STAT

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Manual Trans Neutral Gear Status N/G_STAT

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Power Take Off (PTO) Output Status PTO_STAT_AUX

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Recommended gear GEAR_RCMD

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUP

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Glow plug lamp status supported GPL_SUP

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Manual trans neutral gear status supported N/G_SUP

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Power Take Off (PTO) output status supported PTO_SUP

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Recommended gear supported GEAR_SUP

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Internal

Absence of reagent dosing counter supported REAG_DOSE_TIME_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Actual EGR A supported EGR_A_ACT_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Actual EGR A supported EGR_B_ACT_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Actual SCR catalyst A NH3 storage supported SCR_NH3_ACT_A_SUP

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Actual SCR catalyst B NH3 storage supported SCR_NH3_ACT_B_SUP

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Aftertreatment fuel pressure supported AFT_FP_SUP

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Alternative fuel rail pressure supported FRP_AF_SUP

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Alternative fuel rail temperature supported FRT_AF_SUP

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Alternative fuel tank pressure supported FTP_AF_SUP

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Alternative fuel tank pressure wide range supported FTPW_AF_SUP

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Alternative fuel tank temperature supported FTT_AF_SUP

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Average demanded reagent consumption supported REAG_DEMD_SUP

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Average distance between particulate filter regens supported PF_REGEN_AVGD_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Average reagent consumption supported REAG_RATE_SUP

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Average time between particulate filter regens supported PF_REGEN_AVGT_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Boost bressure A control status BP_A

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Boost bressure A control status BP_B

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 76 to 77 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_B_OLOpen loop
2BP_B_CLClosed loop
3BP_B_FAULTFault

Boost pressure A control status supported BP_A_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Boost pressure A supported BP_A_ACT_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Boost pressure B control status supported BP_B_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Boost pressure B supported BP_B_ACT_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst temperature sensor A supported CATEMP_A_SUP

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst temperature sensor B supported CATEMP_B_SUP

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst temperature sensor C supported CATEMP_C_SUP

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Catalyst temperature sensor D supported CATEMP_D_SUP

  • Service 01PID CF
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Charge air cooler temperature bank 1, sensor 1 supported CACT_11_SUP

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Charge air cooler temperature bank 1, sensor 2 supported CACT_12_SUP

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Charge air cooler temperature bank 2, sensor 1 supported CACT_21_SUP

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Charge air cooler temperature bank 2, sensor 2 supported CACT_22_SUP

  • Service 01PID 77
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded boost pressure A supported BP_A_CMD_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded boost pressure B supported BP_B_CMD_SUP

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded DEF dosing supported DEF_CMD_SUP

  • Service 01PID A5
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded EGR A supported EGR_A_CMD_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded EGR A supported EGR_B_CMD_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded injection control pressure A supported ICP_A_CMD_SUP

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded injection control pressure B supported ICP_B_CMD_SUP

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded intake air flow A control supported IAF_A_CMD_SUP

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded intake air flow B control supported IAF_B_CMD_SUP

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded Throttle Actuator A Control supported? CTAC_A_SUP

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded Throttle Actuator B Control supported? CTAC_B_SUP

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded VGT A position supported VGT_A_CMD_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded VGT B position supported VGT_B_CMD_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded wastegate A position supported WG_A_CMD_SUP

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded wastegate B position supported WG_B_CMD_SUP

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 1 has no result NOXC11_NA

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 1 supported NOXC11_SUP

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 2 has no result NOXC12_NA

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 2 supported NOXC12_SUP

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 3 has no result NOXC13_NA

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 3 supported NOXC13_SUP

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 4 has no result NOXC14_NA

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 1, sensor 4 supported NOXC14_SUP

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 1 has no result NOXC21_NA

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 1 supported NOXC21_SUP

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 2 has no result NOXC22_NA

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 2 supported NOXC22_SUP

  • Service 01PID A1
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 3 has no result NOXC23_NA

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 3 supported NOXC23_SUP

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 4 has no result NOXC24_NA

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Corrected NOx sensor bank 2, sensor 4 supported NOXC24_SUP

  • Service 01PID A8
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Cumulative continuous MI counter supported MI_TIME_CUM_SUP

  • Service 01PID 93
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF concentration supported DEF_CON_SUP

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF doser A dosing mode supported DEFA_MODE_SUP

  • Service 01PID AC
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF doser A maximum dosing rate supported DEFA_MAX_SUP

  • Service 01PID AC
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF doser B commanded dosing supported DEFB_CMD_SUP

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF doser B dosing mode supported DEFB_MODE_SUP

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF doser B maximum dosing rate supported DEFB_MAX_SUP

  • Service 01PID D7
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF tank level supported DEF_LVL_SUP

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF tank temperature supported DEF_T_SUP

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF type supported DEF_TYPE_SUP

  • Service 01PID 9B
  • Module7E0 → 7E8
  • Every5 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

DEF used in the current driving cycle supported DEF_UCDC_SUP

  • Service 01PID A5
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR A error supported EGR_A_ERR_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR A error supported EGR_B_ERR_SUP

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR mass flow rate A supported EGR_M_FL_A_SUP

  • Service 01PID B0
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR mass flow rate B supported EGR_M_FL_B_SUP

  • Service 01PID B0
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUP

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

EGR valve counter supported EGR_TIME_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor A speed supported EMA_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor A torque supported EMA_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor B speed supported EMB_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor B torque supported EMB_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor C speed supported EMC_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor C torque supported EMC_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor D speed supported EMD_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor D torque supported EMD_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor E speed supported EME_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor E torque supported EME_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor F speed supported EMF_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor F torque supported EMF_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor G speed supported EMG_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor G torque supported EMG_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor H speed supported EMH_RPM_SUP

  • Service 01PID CC
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Electric motor H torque supported EMH_TQ_SUP

  • Service 01PID CD
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Engine Percent Torque At Idle, Point 1 TQ_MAX1

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine Percent Torque At Point 2 TQ_MAX2

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine Percent Torque At Point 3 TQ_MAX3

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine Percent Torque At Point 4 TQ_MAX4

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine Percent Torque At Point 5 TQ_MAX5

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Engine-out NOx mass emission rate supported NOX_EO_SUP

  • Service 01PID 97
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system purge pressure supported EVAP_PP_SUP

  • Service 01PID AE
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system purge pressure wide range supported EVAP_PPW_SUP

  • Service 01PID AE
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system sealing status supported EVAP_SEAL_SUP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure A supported EVAP_A_VP_SUP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure A wide range supported EVAP_A_VPW_SUP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure B supported EVAP_B_VP_SUP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure B wide range supported EVAP_B_VPW_SUP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure C supported EVAP_C_VP_SUP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure C wide range supported EVAP_C_VPW_SUP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure D supported EVAP_D_VP_SUP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure D wide range supported EVAP_D_VPW_SUP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 1, sensor 1 supported EGT11_SUP

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 1, sensor 2 supported EGT12_SUP

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 1, sensor 3 supported EGT13_SUP

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 1, sensor 4 supported EGT14_SUP

  • Service 01PID 78
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 2, sensor 1 supported EGT21_SUP

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 2, sensor 2 supported EGT22_SUP

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 2, sensor 3 supported EGT23_SUP

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust gas temperature bank 2, sensor 4 supported EGT24_SUP

  • Service 01PID 79
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust pressure bank 1, sensor 1 supported EP_11_SUP

  • Service 01PID 73
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust pressure bank 1, sensor 2 supported EP_12_SUP

  • Service 01PID CB
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust pressure bank 2, sensor 1 supported EP_21_SUP

  • Service 01PID 73
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Exhaust pressure bank 2, sensor 2 supported EP_22_SUP

  • Service 01PID CB
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection quantity control 1 supported FIQ1_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection quantity control 2 supported FIQ2_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection timing control 1 supported FIT1_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection timing control 2 supported FIT2_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel level input A supported FLI_A_SUP

  • Service 01PID C3
  • Module7E0 → 7E8
  • Every30 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel level input B supported FLI_B_SUP

  • Service 01PID C3
  • Module7E0 → 7E8
  • Every30 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel pressure control 1 supported FP1_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel pressure control 2 supported FP2_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system status bank 1 supported FUELSYS1_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system status bank 2 supported FUELSYS2_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hydrocarbon doser flow rate supported HC_INJ_FL_SUP

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hydrocarbon doser injector duty cycle supported HC_INJ_DC_SUP

  • Service 01PID 96
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 1, Sensor 1 supported IAT_11_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 1, Sensor 1 supported IAT_21_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 1, Sensor 2 supported IAT_12_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 1, Sensor 3 supported IAT_13_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 2, Sensor 2 supported IAT_22_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

IAT Bank 2, Sensor 3 supported IAT_23_SUP

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Idle fuel balance control 1 supported IFB1_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Idle fuel balance control 2 supported IFB2_CL_SUP

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Injection control pressure A supported ICP_A_SUP

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Injection control pressure B supported ICP_B_SUP

  • Service 01PID 6E
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Is ECT sensor 1 supported? ECT_1_SUP

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Is ECT sensor 2 supported? ECT_2_SUP

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Liquid reagent injection system failure counter supported LRIS_FAILURE_TIME_SUP

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Long term fuel trim bank 1 supported LONGFT1_CI_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Long term fuel trim bank 2 supported LONGFT2_CI_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Low-pressure fuel pressure A supported LFP_A_SUP

  • Service 01PID C5
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Low-pressure fuel pressure B supported LFP_B_SUP

  • Service 01PID C5
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

MAF Sensor A supported MAFA_SUP

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

MAF Sensor B supported MAFB_SUP

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Maximum value for air flow rate from mass air flow sensor MAX_MAF

  • Service 01PID 50
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 g/s
Unit
g/s

Maximum value for equivalence ratio MAX_EQ_RAT

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Maximum value for intake manifold absolute pressure (MAP) MAX_MAP

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

Maximum value for oxygen sensor current MAX_O2_CURR

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Maximum value for oxygen sensor voltage MAX_O2_VOLT

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Normalized trigger for particulate filter regen supported PF_REGEN_PCT_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx adsorber desulfurization status supported NOX_ADS_DESULF_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx adsorber regen status supported NOX_ADS_REGEN_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx control monitoring system counter supported MON_SYS_TIME_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 1 has no result NOX11_NA

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 1 supported NOX11_SUP

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 2 has no result NOX12_NA

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 2 supported NOX12_SUP

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 3 has no result NOX13_NA

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 3 supported NOX13_SUP

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 4 has no result NOX14_NA

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 1, sensor 4 supported NOX14_SUP

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 1 has no result NOX21_NA

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 1 supported NOX21_SUP

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 2 has no result NOX22_NA

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 2 supported NOX22_SUP

  • Service 01PID 83
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 3 has no result NOX23_NA

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 3 supported NOX23_SUP

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 4 has no result NOX24_NA

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx sensor bank 2, sensor 4 supported NOX24_SUP

  • Service 01PID A7
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

NOx warning system activation status supported NOX_WARN_ACT_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 1 concentration supported O2S11_PCT_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 1 lambda supported LAMBDA11_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 2 concentration supported O2S12_PCT_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 2 lambda supported LAMBDA12_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 3 concentration supported O2S13_PCT_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 3 lambda supported LAMBDA13_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 4 concentration supported O2S14_PCT_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 4 lambda supported LAMBDA14_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 5 concentration supported O2S15_PCT_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 5 lambda supported LAMBDA15_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 6 concentration supported O2S16_PCT_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 1, sensor 6 lambda supported LAMBDA16_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 1 concentration supported O2S21_PCT_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 1 lambda supported LAMBDA21_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 2 concentration supported O2S22_PCT_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 2 lambda supported LAMBDA22_SUP

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 3 concentration supported O2S23_PCT_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 3 lambda supported LAMBDA23_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 4 concentration supported O2S24_PCT_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 4 lambda supported LAMBDA24_SUP

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 5 concentration supported O2S25_PCT_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 5 lambda supported LAMBDA25_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 6 concentration supported O2S26_PCT_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

O2 sensor bank 2, sensor 6 lambda supported LAMBDA26_SUP

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate control monitoring system counter supported PCD_FAILURE_TIME_SUP

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 1 delta pressure supported DPF1_DP_SUP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 1 inlet pressure supported DPF1_INP_SUP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 1 inlet temperature supported DPF1_INT_SUP

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 1 outlet pressure supported DPF1_OUTP_SUP

  • Service 01PID 7A
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 1 outlet temperature supported DPF1_OUTT_SUP

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 2 delta pressure supported DPF2_DP_SUP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 2 inlet pressure supported DPF2_INP_SUP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 2 inlet temperature supported DPF2_INT_SUP

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 2 outlet pressure supported DPF2_OUTP_SUP

  • Service 01PID 7B
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter bank 2 outlet temperature supported DPF2_OUTT_SUP

  • Service 01PID 7C
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter regen status supported PF_REGEN_STAT_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter regen type supported PF_REGEN_TYPE_SUP

  • Service 01PID 8B
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate filter removal or block counter supported DPF_REMOVAL_BLOCKED_TIME_SUP

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Particulate warning system activation status supported PM_WARN_ACT_SUP

  • Service 01PID C6
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 1, sensor 1 mass concentration supported PM11_SUP

  • Service 01PID 86
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 1, sensor 1 operating status supported PM11_STAT_SUP

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 1, sensor 1 signal supported PM11_OUT_SUP

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 2, sensor 1 mass concentration supported PM21_SUP

  • Service 01PID 86
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 2, sensor 1 operating status supported PM21_STAT_SUP

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

PM sensor bank 2, sensor 1 signal supported PM21_OUT_SUP

  • Service 01PID 8F
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Reagent consumption counter supported REAG_CON_TIME_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Reagent quality counter supported REAG_QUAL_TIME_SUP

  • Service 01PID 94
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Reagent tank level supported REAG_LVL_SUP

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Relative intake air flow A position supported IAF_A_REL_SUP

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Relative intake air flow B position supported IAF_B_REL_SUP

  • Service 01PID 6A
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Relative Throttle A Position data supported? RTP_A_SUP

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Relative Throttle B Position data supported? RTP_B_SUP

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Run time with NOx warning active supported NWI_TIME_SUP

  • Service 01PID 85
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Short term fuel trim bank 1 supported SHRTFT1_CI_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Short term fuel trim bank 2 supported SHRTFT2_CI_SUP

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Tailpipe NOx mass emission rate supported NOX_TP_SUP

  • Service 01PID 97
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Target SCR catalyst A NH3 storage supported SCR_NH3_TGT_A_SUP

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Target SCR catalyst B NH3 storage supported SCR_NH3_TGT_B_SUP

  • Service 01PID 95
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total Engine Run Time supported? RUN_TIME_SUP

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total Idle Run Time supported? IDLE_TIME_SUP

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #1 active supported AECD1_SUP

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #2 active supported AECD2_SUP

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #3 active supported AECD3_SUP

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #4 active supported AECD4_SUP

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #5 active supported AECD5_SUP

  • Service 01PID 81
  • Module7E0 → 7E8
  • Every60 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #6 active supported AECD6_SUP

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #7 active supported AECD7_SUP

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #8 active supported AECD8_SUP

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #9 active supported AECD9_SUP

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #10 active supported AECD10_SUP

  • Service 01PID 82
  • Module7E0 → 7E8
  • Every60 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #11 active supported AECD11_SUP

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #12 active supported AECD12_SUP

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #13 active supported AECD13_SUP

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #14 active supported AECD14_SUP

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #15 active supported AECD15_SUP

  • Service 01PID 89
  • Module7E0 → 7E8
  • Every60 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #16 active supported AECD16_SUP

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #17 active supported AECD17_SUP

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #18 active supported AECD18_SUP

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #19 active supported AECD19_SUP

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #20 active supported AECD20_SUP

  • Service 01PID 8A
  • Module7E0 → 7E8
  • Every60 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #21 active supported AECD21_SUP

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #22 active supported AECD22_SUP

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #23 active supported AECD23_SUP

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #24 active supported AECD24_SUP

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total run time with EI-AECD #25 active supported AECD25_SUP

  • Service 01PID DC
  • Module7E0 → 7E8
  • Every60 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Total Run Time With PTO Active supported? PTO_TIME_SUP

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Transmission actual gear ratio supported GEAR_RAT_SUP

  • Service 01PID A4
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Transmission actual gear supported GEAR_ACT_SUP

  • Service 01PID A4
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo A compressor inlet temperature supported TCA_CINT_SUP

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo A compressor outlet temperature supported TCA_COUTT_SUP

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo A turbine inlet temperature supported TCA_TINT_SUP

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo A turbine outlet temperature supported TCA_TOUTT_SUP

  • Service 01PID 75
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo B compressor inlet temperature supported TCB_CINT_SUP

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo B compressor outlet temperature supported TCB_COUTT_SUP

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo B turbine inlet temperature supported TCB_TINT_SUP

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbo B turbine outlet temperature supported TCB_TOUTT_SUP

  • Service 01PID 76
  • Module7E0 → 7E8
  • Every1 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbocharger A speed supported TCA_RPM_SUP

  • Service 01PID 74
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Turbocharger B speed supported TCB_RPM_SUP

  • Service 01PID 74
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

VGT A control status supported VGT_A_STAT_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

VGT A position supported VGT_A_ACT_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

VGT B control status supported VGT_B_STAT_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

VGT B position supported VGT_B_ACT_SUP

  • Service 01PID 71
  • Module7E0 → 7E8
  • Every1 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Wastegate A position supported WG_A_ACT_SUP

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Wastegate B position supported WG_B_ACT_SUP

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 1, Sensor 2 present O2S12_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 1, Sensor 3 present O2S13_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 1, Sensor 4 present O2S14_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 2, Sensor 1 present O2S21_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 2, Sensor 2 present O2S22_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 2, Sensor 3 present O2S23_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

02S Bank 2, Sensor 4 present O2S24_EXISTS

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENT

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLT

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 2 LAMBDA12_CURRENT

  • Service 01PID 35
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 2 LAMBDA12_VOLT

  • Service 01PID 25
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 3 LAMBDA13_CURRENT

Bank 1, sensor 3 on engines that report sensor locations with 01 13; bank 2, sensor 1 with 01 1D.

  • Service 01PID 36
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 3 LAMBDA13_VOLT

Bank 1, sensor 3 on engines that report sensor locations with 01 13; bank 2, sensor 1 with 01 1D.

  • Service 01PID 26
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 4 LAMBDA14_CURRENT

Bank 1, sensor 4 on engines that report sensor locations with 01 13; bank 2, sensor 2 with 01 1D.

  • Service 01PID 37
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 1, Sensor 4 LAMBDA14_VOLT

Bank 1, sensor 4 on engines that report sensor locations with 01 13; bank 2, sensor 2 with 01 1D.

  • Service 01PID 27
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 1 LAMBDA21_CURRENT

Bank 2, sensor 1 on engines that report sensor locations with 01 13; bank 3, sensor 1 with 01 1D.

  • Service 01PID 38
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 1 LAMBDA21_VOLT

Bank 2, sensor 1 on engines that report sensor locations with 01 13; bank 3, sensor 1 with 01 1D.

  • Service 01PID 28
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 2 LAMBDA22_CURRENT

Bank 2, sensor 2 on engines that report sensor locations with 01 13; bank 3, sensor 2 with 01 1D.

  • Service 01PID 39
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 2 LAMBDA22_VOLT

Bank 2, sensor 2 on engines that report sensor locations with 01 13; bank 3, sensor 2 with 01 1D.

  • Service 01PID 29
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 3 LAMBDA23_CURRENT

Bank 2, sensor 3 on engines that report sensor locations with 01 13; bank 4, sensor 1 with 01 1D.

  • Service 01PID 3A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 3 LAMBDA23_VOLT

Bank 2, sensor 3 on engines that report sensor locations with 01 13; bank 4, sensor 1 with 01 1D.

  • Service 01PID 2A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 4 LAMBDA24_CURRENT

Bank 2, sensor 4 on engines that report sensor locations with 01 13; bank 4, sensor 2 with 01 1D.

  • Service 01PID 3B
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Lambda value, Equivalence Ratio Bank 2, Sensor 4 LAMBDA24_VOLT

Bank 2, sensor 4 on engines that report sensor locations with 01 13; bank 4, sensor 2 with 01 1D.

  • Service 01PID 2B
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

O2 concentration bank 1, sensor 1 O2S11_PCT

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 1, sensor 2 O2S12_PCT

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 1, sensor 3 O2S13_PCT

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 1, sensor 4 O2S14_PCT

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 1, sensor 5 O2S15_PCT

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 1, sensor 6 O2S16_PCT

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 1 O2S21_PCT

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 2 O2S22_PCT

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 3 O2S23_PCT

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 4 O2S24_PCT

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 5 O2S25_PCT

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 concentration bank 2, sensor 6 O2S26_PCT

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

O2 sensor lambda bank 1, sensor 1 LAMBDA11

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 1, sensor 2 LAMBDA12

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 1, sensor 3 LAMBDA13

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 1, sensor 4 LAMBDA14

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 1, sensor 5 LAMBDA15

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 87 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 1, sensor 6 LAMBDA16

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 88 to 103 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 1 LAMBDA21

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 2 LAMBDA22

  • Service 01PID 8C
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 3 LAMBDA23

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 4 LAMBDA24

  • Service 01PID 9C
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 5 LAMBDA25

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 104 to 119 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2 sensor lambda bank 2, sensor 6 LAMBDA26

  • Service 01PID C9
  • Module7E0 → 7E8
  • Every1 s

Bits 120 to 135 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.99987793
Unit
Number

O2S Output Voltage Bank 1, Sensor 1 O2S11

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 1, Sensor 2 O2S12

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 1, Sensor 3 O2S13

Bank 1, sensor 3 on engines that report sensor locations with 01 13; bank 2, sensor 1 with 01 1D.

  • Service 01PID 16
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 1, Sensor 4 O2S14

Bank 1, sensor 4 on engines that report sensor locations with 01 13; bank 2, sensor 2 with 01 1D.

  • Service 01PID 17
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 2, Sensor 1 O2S21

  • Service 01PID 18
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 2, Sensor 2 O2S22

  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 2, Sensor 3 O2S23

Bank 2, sensor 3 on engines that report sensor locations with 01 13; bank 4, sensor 1 with 01 1D.

  • Service 01PID 1A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

O2S Output Voltage Bank 2, Sensor 4 O2S24

Bank 2, sensor 4 on engines that report sensor locations with 01 13; bank 4, sensor 2 with 01 1D.

  • Service 01PID 1B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

SHRTFT associated with O2S11 SHRTFT11

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S12 SHRTFT12

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S13 SHRTFT13

  • Service 01PID 16
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S14 SHRTFT14

  • Service 01PID 17
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S21 SHRTFT21

  • Service 01PID 18
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S22 SHRTFT22

  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S23 SHRTFT23

  • Service 01PID 1A
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

SHRTFT associated with O2S24 SHRTFT24

  • Service 01PID 1B
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENT

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 2 O2S12_CURRENT

  • Service 01PID 35
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 3 O2S13_CURRENT

  • Service 01PID 36
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 4 O2S14_CURRENT

  • Service 01PID 37
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 2, Sensor 1 O2S21_CURRENT

  • Service 01PID 38
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 2, Sensor 2 O2S22_CURRENT

  • Service 01PID 39
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 2, Sensor 3 O2S23_CURRENT

  • Service 01PID 3A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Current, O2 Sensor Bank 2, Sensor 4 O2S24_CURRENT

  • Service 01PID 3B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLT

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 2 O2S12_VOLT

  • Service 01PID 25
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 3 O2S13_VOLT

  • Service 01PID 26
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 4 O2S14_VOLT

  • Service 01PID 27
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 2, Sensor 1 O2S21_VOLT

  • Service 01PID 28
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 2, Sensor 2 O2S22_VOLT

  • Service 01PID 29
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 2, Sensor 3 O2S23_VOLT

  • Service 01PID 2A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Wide Range O2S Voltage, O2 Sensor Bank 2, Sensor 4 O2S24_VOLT

  • Service 01PID 2B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Fuel

Alcohol fuel percentage ALCH_PCT

Indicates the percentage of alcohol contained in ethanol or methanol fuels, if used. For example, ethanol fuel (E85) normally contains 85% ethanol, in which case this parameter will display 85%

  • Service 01PID 52
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Alternative fuel rail pressure FRP_AF

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Alternative fuel rail temperature FRT_AF

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Alternative fuel tank pressure FTP_AF

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 47 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 kPa
Unit
kPa

Alternative fuel tank pressure, wide range FTPW_AF

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Alternative fuel tank temperature FTT_AF

  • Service 01PID AB
  • Module7E0 → 7E8
  • Every1 s

Bits 64 to 71 of the reply, 8 bits.

Formula
val×2−256
Range
-256 to 254 °C
Unit
°C

Commanded Fuel Rail Pressure A FRP_A_CMD

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Commanded Fuel Rail Pressure B FRP_B_CMD

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Engine exhaust flow rate EXH_RATE

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Engine fuel rate FUEL_RATE

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Engine fuel rate (alternate) FUEL_RATE_ALT

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Evap system purge pressure EVAP_PP

  • Service 01PID AE
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8.192 to 8.19175 kPa
Unit
kPa

Evap system purge pressure, wide range EVAP_PPW

  • Service 01PID AE
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.536 to 65.534 kPa
Unit
kPa

Evap system sealed EVAP_SEAL

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Evap system vapor pressure A EVAP_A_VP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8.192 to 8.19175 kPa
Unit
kPa

Evap system vapor pressure A, wide range EVAP_A_VPW

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.536 to 65.534 kPa
Unit
kPa

Evap system vapor pressure B EVAP_B_VP

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8.192 to 8.19175 kPa
Unit
kPa

Evap system vapor pressure B, wide range EVAP_B_VPW

  • Service 01PID A3
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.536 to 65.534 kPa
Unit
kPa

Evap system vapor pressure C EVAP_C_VP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8.192 to 8.19175 kPa
Unit
kPa

Evap system vapor pressure C, wide range EVAP_C_VPW

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.536 to 65.534 kPa
Unit
kPa

Evap system vapor pressure D EVAP_D_VP

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8.192 to 8.19175 kPa
Unit
kPa

Evap system vapor pressure D, wide range EVAP_D_VPW

  • Service 01PID CE
  • Module7E0 → 7E8
  • Every1 s

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.536 to 65.534 kPa
Unit
kPa

Fuel injection quantity control 1 in closed loop FIQ1_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection quantity control 2 in closed loop FIQ2_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection timing control 1 in closed loop FIT1_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel injection timing control 2 in closed loop FIT2_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel level input A FLI_A

  • Service 01PID C3
  • Module7E0 → 7E8
  • Every30 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel level input B FLI_B

  • Service 01PID C3
  • Module7E0 → 7E8
  • Every30 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel pressure control 1 in closed loop FP1_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel pressure control 2 in closed loop FP2_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel Rail Pressure A FRP_A

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Fuel Rail Pressure B FRP_B

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Fuel Rail Temperature A FRT_A

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Fuel Rail Temperature B FRT_B

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Fuel system 1 status FUELSYS1

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Fuel system 2 status FUELSYS2

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Fuel system A use percentage bank 1 FUELSYSA_B1

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system A use percentage bank 2 FUELSYSA_B2

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system A use percentage bank 3 FUELSYSA_B3

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system A use percentage bank 4 FUELSYSA_B4

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system B use percentage bank 1 FUELSYSB_B1

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system B use percentage bank 2 FUELSYSB_B2

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system B use percentage bank 3 FUELSYSB_B3

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system B use percentage bank 4 FUELSYSB_B4

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel system bank 1 in closed loop FUELSYS1_CL

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system bank 1 in open loop FUELSYS1_OL

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system bank 1 in open loop due to a malfunction FUELSYS1_OL_FAULT

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system bank 2 in closed loop FUELSYS2_CL

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system bank 2 in open loop FUELSYS2_OL

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system bank 2 in open loop due to a malfunction FUELSYS2_OL_FAULT

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel tank level FLI

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Idle fuel balance control 1 in closed loop IFB1_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Idle fuel balance control 2 in closed loop IFB2_CL

  • Service 01PID 92
  • Module7E0 → 7E8
  • Every1 s

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Long term fuel trim bank 1, compression ignition LONGFT1_CI

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.21875 %
Unit
%

Long term fuel trim bank 2, compression ignition LONGFT2_CI

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.21875 %
Unit
%

Low-pressure fuel pressure A LFP_A

  • Service 01PID C5
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 23 of the reply, 16 bits.

Formula
val×791000
Range
0 to 5177.265 kPa
Unit
kPa

Low-pressure fuel pressure B LFP_B

  • Service 01PID C5
  • Module7E0 → 7E8
  • Every1 s

Bits 24 to 39 of the reply, 16 bits.

Formula
val×791000
Range
0 to 5177.265 kPa
Unit
kPa

Short term fuel trim bank 1, compression ignition SHRTFT1_CI

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.21875 %
Unit
%

Short term fuel trim bank 2, compression ignition SHRTFT2_CI

  • Service 01PID B1
  • Module7E0 → 7E8
  • Every1 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.21875 %
Unit
%

Vehicle fuel rate VFUEL_RATE

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel Rail Pressure A data supported? FRP_A_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel Rail Pressure B data supported? FRP_B_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUP

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel Temperature A data supported? FRT_A_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Fuel Temperature B data supported? FRT_B_SUP

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Movement

Maximum current vehicle speed limit V_SET

  • Service 01PID AA
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Vehicle speed VSS

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

OBD

OBD requirements to which vehicle is designed OBDSUP

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Trips

Distance since module reflash or replacement REFLASH_DIST

  • Service 01PID C7
  • Module7E0 → 7E8
  • Every30 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Engine odometer ODO_ENG

  • Service 01PID D3
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Odometer ODO

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Keyboard shortcuts