Parameters
The smart fortwo has 329 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V system voltage, hd FORTWO_EQA_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 1998 to 2024.
Auxiliary battery voltage FORTWO_EQA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.9 V
- Unit
- V
In testing for 1998 to 2024.
Battery age condition FORTWO_ED_BAT_AGE
- Service 22
DID 6308 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1998 to 2024.
Battery heater on FORTWO_ED_HEATER_ON
- Service 22
DID D302 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2024.
Battery module 1 temperature FORTWO_ED_MOD_T1
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 2 temperature FORTWO_ED_MOD_T2
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 3 temperature FORTWO_ED_MOD_T3
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 4 temperature FORTWO_ED_MOD_T4
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 5 temperature FORTWO_ED_MOD_T5
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 6 temperature FORTWO_ED_MOD_T6
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 7 temperature FORTWO_ED_MOD_T7
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 8 temperature FORTWO_ED_MOD_T8
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery module 9 temperature FORTWO_ED_MOD_T9
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
Battery operating mode FORTWO_EV_MODE
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 7
- Unit
- Number
In testing for 1998 to 2024.
Capacity loss FORTWO_CAP_LOSS
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
Cell capacity, average FORTWO_ED_CAP_AS_AVG
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Cell capacity, maximum FORTWO_ED_CAP_AS_MAX
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Cell capacity, minimum FORTWO_ED_CAP_AS_MIN
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Cell voltage reference, average FORTWO_ED_ADC_V_AVG
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1998 to 2024.
Cell voltage reference, maximum FORTWO_ED_ADC_V_MAX
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 1998 to 2024.
Cell voltage reference, minimum FORTWO_ED_ADC_V_MIN
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 1998 to 2024.
Charger 12V output voltage FORTWO_ED_OBL_LV
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1998 to 2024.
Charger cooling plate temperature FORTWO_ED_OBL_PLATE_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2024.
Charger current set point FORTWO_ED_OBL_A_SET
- Service 22
DID 022A - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
In testing for 1998 to 2024.
Charger HV output current FORTWO_ED_OBL_HV_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 204.7 A
- Unit
- A
In testing for 1998 to 2024.
Charger HV output voltage FORTWO_ED_OBL_HV
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 819 V
- Unit
- V
In testing for 1998 to 2024.
Charger mains current FORTWO_ED_OBL_MAINS_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 204.7 A
- Unit
- A
In testing for 1998 to 2024.
Charger mains current, phase 1 FORTWO_OBL_A1
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 1998 to 2024.
Charger mains current, phase 2 FORTWO_OBL_A2
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 1998 to 2024.
Charger mains voltage FORTWO_ED_OBL_MAINS_V
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 819 V
- Unit
- V
In testing for 1998 to 2024.
Charger mains voltage FORTWO_OBL_V
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 V
- Unit
- V
In testing for 1998 to 2024.
Charger power 1 FORTWO_OBL_P1
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 1998 to 2024.
Charger power 2 FORTWO_OBL_P2
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 1998 to 2024.
Charger temperature FORTWO_ED_OBL_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2024.
Charging cable current code FORTWO_ED_OBL_CABLE_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 1998 to 2024.
Charging plug detected FORTWO_PLUG
Pelican can show this parameter as the plug state.
- Service 22
DID 339D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Charging socket temperature FORTWO_ED_OBL_SOCKET_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2024.
DC converter requested voltage FORTWO_EQA_CNVRTR_REQ_V
- Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 1998 to 2024.
Estimated capacity FORTWO_CAP_EST
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Highest cell voltage FORTWO_CELL_V_MAX
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
HV battery amperage FORTWO_EQA_HV_A
- Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 A
- Unit
- A
In testing for 1998 to 2024.
HV battery available energy FORTWO_HV_E
- Service 22
DID 320C - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kWh
- Unit
- kWh
In testing for 1998 to 2024.
HV battery coolant temperature FORTWO_EQA_HV_COOLANT_T
- Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 °C
- Unit
- °C
In testing for 1998 to 2024.
HV battery current FORTWO_ED_HV_A
- Service 22
DID 0203 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.9687 A
- Unit
- A
In testing for 1998 to 2024.
HV battery current FORTWO_HV_A
Pelican can show this parameter as the traction battery current.
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1023.9687 to 1024 A
- Unit
- A
In testing for 1998 to 2024.
HV battery open-circuit voltage FORTWO_OCV
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1998 to 2024.
HV battery state of charge FORTWO_EQA_HV_SOC
Pelican can show this parameter as the state of charge.
- Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2024.
HV battery temperature FORTWO_ED_HV_T
- Service 22
DID 0201 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
HV battery temperature, average FORTWO_HV_T_AVG
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
HV battery temperature, maximum FORTWO_HV_T_MAX
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
HV battery temperature, minimum FORTWO_HV_T_MIN
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1998 to 2024.
HV battery voltage FORTWO_ED_HV_V
- Service 22
DID 0204 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1998 to 2024.
HV battery voltage FORTWO_EQA_HV_V
- Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 1998 to 2024.
HV battery voltage FORTWO_HV_V
Pelican can show this parameter as the traction battery voltage.
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1998 to 2024.
HV contactor cycles remaining FORTWO_ED_CONT_LEFT
- Service 22
DID 030B - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
In testing for 1998 to 2024.
HV contactor cycles remaining FORTWO_HV_CONT_LEFT
- Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1998 to 2024.
HV contactor cycles, maximum FORTWO_ED_CONT_MAX
- Service 22
DID 030C - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
In testing for 1998 to 2024.
HV contactor cycles, maximum FORTWO_HV_CONT_MAX
- Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1998 to 2024.
HV contactor state FORTWO_ED_CONTACTOR
- Service 22
DID D000 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
HV contactor state FORTWO_HV_CONTACTOR
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
In testing for 1998 to 2024.
HV DC fault code FORTWO_ED_DC_FAULT
- Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
HV isolation resistance FORTWO_ED_ISO
- Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65534 kΩ
- Unit
- kΩ
In testing for 1998 to 2024.
HV link voltage FORTWO_HV_LINK_V
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1998 to 2024.
HV plug interlock closed FORTWO_HV_INTERLOCK_PLUG
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Initial capacity FORTWO_CAP_INIT
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Leakage current, 10 kilohertz FORTWO_LEAK_HF10
- Service 22
DID 5066 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Leakage DC current FORTWO_LEAK_DC
- Service 22
DID 5065 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Leakage diagnostic code FORTWO_LEAK_DIAG
- Service 22
DID 5064 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
Leakage high-frequency current FORTWO_LEAK_HF
- Service 22
DID 5067 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Leakage low-frequency current FORTWO_LEAK_LF
- Service 22
DID 5068 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Lowest cell voltage FORTWO_CELL_V_MIN
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Mains active power FORTWO_MAINS_P
- Service 22
DID 504A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -20 to 45.5349 kW
- Unit
- kW
In testing for 1998 to 2024.
Mains current limit FORTWO_MAINS_A_LIMIT
- Service 22
DID 5070 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Mains current, phase 2 FORTWO_MAINS_A_2
- Service 22
DID 503A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 1998 to 2024.
Mains current, phase 3 FORTWO_MAINS_A_3
- Service 22
DID 503B - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 1998 to 2024.
Mains frequency FORTWO_MAINS_HZ
- Service 22
DID 5049 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 10 to 521.9921 Hz
- Unit
- Hz
In testing for 1998 to 2024.
Mains ground resistance FORTWO_MAINS_GND_R
- Service 22
DID 5062 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1998 to 2024.
Mains voltage, phases 1-2 FORTWO_MAINS_V_12
- Service 22
DID 503F - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1998 to 2024.
Mains voltage, phases 2-3 FORTWO_MAINS_V_23
- Service 22
DID 5041 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1998 to 2024.
Mains voltage, phases 3-1 FORTWO_MAINS_V_31
- Service 22
DID 5042 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1998 to 2024.
Open-circuit voltage state FORTWO_OCV_STATE
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4
- Unit
- Number
In testing for 1998 to 2024.
Real state of charge, maximum FORTWO_SOC_REAL_MAX
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
Real state of charge, minimum FORTWO_SOC_REAL_MIN
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
Service interlock closed FORTWO_HV_INTERLOCK_SVC
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
State of charge FORTWO_SOC
Pelican can show this parameter as the state of charge.
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
State of charge recalibration state FORTWO_SOC_RECAL
- Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
In testing for 1998 to 2024.
State of charge, displayed FORTWO_SOC_DISPLAY
- Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
State of health FORTWO_SOH
Pelican can show this parameter as the state of health.
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1998 to 2024.
State of health, raw FORTWO_ED_SOH
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
Sum of cell voltages FORTWO_HV_CELL_SUM_V
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1998 to 2024.
Time with HV off FORTWO_ED_HV_OFF_TIME
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 1998 to 2024.
Usable capacity, full FORTWO_CAP_FULL
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -91.0222 to 91.0194 Ah
- Unit
- Ah
In testing for 1998 to 2024.
Cells
Cell 1 voltage FORTWO_CELL_V1
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 1 voltage FORTWO_ED_CELL_V1
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 2 voltage FORTWO_CELL_V2
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 2 voltage FORTWO_ED_CELL_V2
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 3 voltage FORTWO_CELL_V3
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 3 voltage FORTWO_ED_CELL_V3
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 4 voltage FORTWO_CELL_V4
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 4 voltage FORTWO_ED_CELL_V4
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 5 voltage FORTWO_CELL_V5
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 5 voltage FORTWO_ED_CELL_V5
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 6 voltage FORTWO_CELL_V6
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 6 voltage FORTWO_ED_CELL_V6
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 7 voltage FORTWO_CELL_V7
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 7 voltage FORTWO_ED_CELL_V7
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 8 voltage FORTWO_CELL_V8
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 8 voltage FORTWO_ED_CELL_V8
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 9 voltage FORTWO_CELL_V9
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 9 voltage FORTWO_ED_CELL_V9
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 10 voltage FORTWO_CELL_V10
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 10 voltage FORTWO_ED_CELL_V10
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 11 voltage FORTWO_CELL_V11
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 11 voltage FORTWO_ED_CELL_V11
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 12 voltage FORTWO_CELL_V12
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 12 voltage FORTWO_ED_CELL_V12
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 13 voltage FORTWO_CELL_V13
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 13 voltage FORTWO_ED_CELL_V13
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 14 voltage FORTWO_CELL_V14
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 14 voltage FORTWO_ED_CELL_V14
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 15 voltage FORTWO_CELL_V15
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 15 voltage FORTWO_ED_CELL_V15
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 16 voltage FORTWO_CELL_V16
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 16 voltage FORTWO_ED_CELL_V16
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 17 voltage FORTWO_CELL_V17
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 17 voltage FORTWO_ED_CELL_V17
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 18 voltage FORTWO_CELL_V18
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 18 voltage FORTWO_ED_CELL_V18
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 19 voltage FORTWO_CELL_V19
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 19 voltage FORTWO_ED_CELL_V19
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 20 voltage FORTWO_CELL_V20
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 20 voltage FORTWO_ED_CELL_V20
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 21 voltage FORTWO_CELL_V21
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 21 voltage FORTWO_ED_CELL_V21
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 22 voltage FORTWO_CELL_V22
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 22 voltage FORTWO_ED_CELL_V22
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 23 voltage FORTWO_CELL_V23
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 23 voltage FORTWO_ED_CELL_V23
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 24 voltage FORTWO_CELL_V24
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 24 voltage FORTWO_ED_CELL_V24
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 25 voltage FORTWO_CELL_V25
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 25 voltage FORTWO_ED_CELL_V25
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 26 voltage FORTWO_CELL_V26
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 26 voltage FORTWO_ED_CELL_V26
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 27 voltage FORTWO_CELL_V27
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 27 voltage FORTWO_ED_CELL_V27
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 28 voltage FORTWO_CELL_V28
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 28 voltage FORTWO_ED_CELL_V28
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 29 voltage FORTWO_CELL_V29
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 29 voltage FORTWO_ED_CELL_V29
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 30 voltage FORTWO_CELL_V30
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 30 voltage FORTWO_ED_CELL_V30
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 31 voltage FORTWO_CELL_V31
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 31 voltage FORTWO_ED_CELL_V31
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 32 voltage FORTWO_CELL_V32
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 32 voltage FORTWO_ED_CELL_V32
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 33 voltage FORTWO_CELL_V33
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 33 voltage FORTWO_ED_CELL_V33
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 34 voltage FORTWO_CELL_V34
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 34 voltage FORTWO_ED_CELL_V34
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 35 voltage FORTWO_CELL_V35
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 35 voltage FORTWO_ED_CELL_V35
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 36 voltage FORTWO_CELL_V36
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 36 voltage FORTWO_ED_CELL_V36
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 37 voltage FORTWO_CELL_V37
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 37 voltage FORTWO_ED_CELL_V37
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 38 voltage FORTWO_CELL_V38
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 38 voltage FORTWO_ED_CELL_V38
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 39 voltage FORTWO_CELL_V39
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 39 voltage FORTWO_ED_CELL_V39
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 40 voltage FORTWO_CELL_V40
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 40 voltage FORTWO_ED_CELL_V40
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 41 voltage FORTWO_CELL_V41
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 41 voltage FORTWO_ED_CELL_V41
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 42 voltage FORTWO_CELL_V42
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 42 voltage FORTWO_ED_CELL_V42
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 43 voltage FORTWO_CELL_V43
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 43 voltage FORTWO_ED_CELL_V43
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 44 voltage FORTWO_CELL_V44
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 44 voltage FORTWO_ED_CELL_V44
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 45 voltage FORTWO_CELL_V45
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 45 voltage FORTWO_ED_CELL_V45
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 46 voltage FORTWO_CELL_V46
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 46 voltage FORTWO_ED_CELL_V46
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 47 voltage FORTWO_CELL_V47
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 47 voltage FORTWO_ED_CELL_V47
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 48 voltage FORTWO_CELL_V48
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 48 voltage FORTWO_ED_CELL_V48
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 49 voltage FORTWO_CELL_V49
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 49 voltage FORTWO_ED_CELL_V49
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 50 voltage FORTWO_CELL_V50
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 50 voltage FORTWO_ED_CELL_V50
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 51 voltage FORTWO_CELL_V51
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 51 voltage FORTWO_ED_CELL_V51
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 52 voltage FORTWO_CELL_V52
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 52 voltage FORTWO_ED_CELL_V52
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 53 voltage FORTWO_CELL_V53
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 53 voltage FORTWO_ED_CELL_V53
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 54 voltage FORTWO_CELL_V54
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 54 voltage FORTWO_ED_CELL_V54
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 55 voltage FORTWO_CELL_V55
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 55 voltage FORTWO_ED_CELL_V55
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 56 voltage FORTWO_CELL_V56
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 56 voltage FORTWO_ED_CELL_V56
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 57 voltage FORTWO_CELL_V57
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 57 voltage FORTWO_ED_CELL_V57
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 58 voltage FORTWO_CELL_V58
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 58 voltage FORTWO_ED_CELL_V58
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 59 voltage FORTWO_CELL_V59
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 59 voltage FORTWO_ED_CELL_V59
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 60 voltage FORTWO_CELL_V60
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 60 voltage FORTWO_ED_CELL_V60
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 61 voltage FORTWO_CELL_V61
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 61 voltage FORTWO_ED_CELL_V61
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 62 voltage FORTWO_CELL_V62
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 62 voltage FORTWO_ED_CELL_V62
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 63 voltage FORTWO_CELL_V63
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 63 voltage FORTWO_ED_CELL_V63
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 64 voltage FORTWO_CELL_V64
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 64 voltage FORTWO_ED_CELL_V64
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 65 voltage FORTWO_CELL_V65
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 65 voltage FORTWO_ED_CELL_V65
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 66 voltage FORTWO_CELL_V66
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 66 voltage FORTWO_ED_CELL_V66
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 67 voltage FORTWO_CELL_V67
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 67 voltage FORTWO_ED_CELL_V67
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 68 voltage FORTWO_CELL_V68
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 68 voltage FORTWO_ED_CELL_V68
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 69 voltage FORTWO_CELL_V69
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 69 voltage FORTWO_ED_CELL_V69
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 70 voltage FORTWO_CELL_V70
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 70 voltage FORTWO_ED_CELL_V70
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 71 voltage FORTWO_CELL_V71
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 71 voltage FORTWO_ED_CELL_V71
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 72 voltage FORTWO_CELL_V72
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 72 voltage FORTWO_ED_CELL_V72
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 73 voltage FORTWO_CELL_V73
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 73 voltage FORTWO_ED_CELL_V73
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 74 voltage FORTWO_CELL_V74
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 74 voltage FORTWO_ED_CELL_V74
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 75 voltage FORTWO_CELL_V75
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 75 voltage FORTWO_ED_CELL_V75
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 76 voltage FORTWO_CELL_V76
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 76 voltage FORTWO_ED_CELL_V76
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 77 voltage FORTWO_CELL_V77
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 77 voltage FORTWO_ED_CELL_V77
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 78 voltage FORTWO_CELL_V78
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 78 voltage FORTWO_ED_CELL_V78
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 79 voltage FORTWO_CELL_V79
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 79 voltage FORTWO_ED_CELL_V79
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 80 voltage FORTWO_CELL_V80
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 80 voltage FORTWO_ED_CELL_V80
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 81 voltage FORTWO_CELL_V81
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 81 voltage FORTWO_ED_CELL_V81
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 82 voltage FORTWO_CELL_V82
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 82 voltage FORTWO_ED_CELL_V82
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 83 voltage FORTWO_CELL_V83
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 83 voltage FORTWO_ED_CELL_V83
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 84 voltage FORTWO_CELL_V84
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 84 voltage FORTWO_ED_CELL_V84
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 85 voltage FORTWO_CELL_V85
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 85 voltage FORTWO_ED_CELL_V85
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 86 voltage FORTWO_CELL_V86
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 86 voltage FORTWO_ED_CELL_V86
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 87 voltage FORTWO_CELL_V87
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 87 voltage FORTWO_ED_CELL_V87
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 88 voltage FORTWO_CELL_V88
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 88 voltage FORTWO_ED_CELL_V88
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 89 voltage FORTWO_CELL_V89
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 89 voltage FORTWO_ED_CELL_V89
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 90 voltage FORTWO_CELL_V90
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 90 voltage FORTWO_ED_CELL_V90
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 91 voltage FORTWO_CELL_V91
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 91 voltage FORTWO_ED_CELL_V91
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 92 voltage FORTWO_CELL_V92
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 92 voltage FORTWO_ED_CELL_V92
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 93 voltage FORTWO_CELL_V93
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 93 voltage FORTWO_ED_CELL_V93
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2024.
Cell 94 voltage FORTWO_CELL_V94
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 95 voltage FORTWO_CELL_V95
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Cell 96 voltage FORTWO_CELL_V96
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1998 to 2024.
Brakes
Vacuum pump pressure 1 FORTWO_ED_VAC_P1
- Service 22
DID 2041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 1998 to 2024.
Vacuum pump pressure 2 FORTWO_ED_VAC_P2
- Service 22
DID 2043 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 1998 to 2024.
Climate
Cabin blower command FORTWO_BLOWER
- Service 22
DID 34CB - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2024.
Outside temperature FORTWO_AAT
- Service 22
DID 200C - Module
743 → 763 - Every
20 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1998 to 2024.
Details
Days to next service FORTWO_SVC_DAYS
- Service 22
DID 0204 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2024.
Distance to next service FORTWO_SVC_DIST
- Service 22
DID 0203 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2024.
Service level FORTWO_SVC_LEVEL
- Service 22
DID 0188 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2024.
Doors
Driver door locked FORTWO_DRIVER_LOCKED
- Service 21
PID 25 - Module
745 → 765 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Drivetrain
Motor speed FORTWO_MOTOR_RPM
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 1998 to 2024.
Electrical
12V supply voltage, battery controller FORTWO_12V_V_BMS
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 31.875 V
- Unit
- V
In testing for 1998 to 2024.
DC/DC activation request FORTWO_DCDC_REQ
- Service 22
DID 3022 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
DC/DC load FORTWO_DCDC_LOAD
- Service 22
DID 3495 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.21875 %
- Unit
- %
In testing for 1998 to 2024.
DC/DC output current FORTWO_DCDC_A
- Service 22
DID 3025 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 A
- Unit
- A
In testing for 1998 to 2024.
DC/DC output power FORTWO_DCDC_P
- Service 22
DID 3494 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 W
- Unit
- W
In testing for 1998 to 2024.
DC/DC output voltage FORTWO_DCDC_V
- Service 22
DID 3024 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 4 to 29.5 V
- Unit
- V
In testing for 1998 to 2024.
DC/DC voltage request FORTWO_DCDC_V_REQ
- Service 22
DID 3023 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 12 to 24.75 V
- Unit
- V
In testing for 1998 to 2024.
Power distribution 12V voltage FORTWO_USM_V
- Service 22
DID 3301 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 6 to 21.2999 V
- Unit
- V
In testing for 1998 to 2024.
Engine
Coolant pump current FORTWO_ED_PUMP_A
- Service 22
DID 2309 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 1998 to 2024.
Coolant pump speed FORTWO_ED_PUMP_DUTY
- Service 22
DID D032 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2024.
Coolant pump temperature FORTWO_ED_PUMP_T
- Service 22
DID 230A - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1998 to 2024.
Coolant pump voltage FORTWO_ED_PUMP_V
- Service 22
DID 2308 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1998 to 2024.
Coolant temperature FORTWO_ED_COOLANT_T
- Service 22
DID 2047 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191.875 °C
- Unit
- °C
In testing for 1998 to 2024.
Cooling fan speed FORTWO_ED_FAN_DUTY
- Service 22
DID D041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2024.
Distance to next service FORTWO_EQA_SERVICE_DIST
- Service 22
DID 6504 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2024.
Stats
Battery heater operating time FORTWO_ED_HEATER_HOURS
- Service 22
DID 6321 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 1998 to 2024.
Coolant pump operating time FORTWO_ED_PUMP_HOURS
- Service 22
DID 6309 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 1998 to 2024.
Cooling fan operating time FORTWO_ED_FAN_HOURS
- Service 22
DID 630A - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 1998 to 2024.
Tires
Tire sensor 1 battery low FORTWO_TPMS_LOWBAT_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 1 missing FORTWO_TPMS_MISSING_1
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 207 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 1 pressure FORTWO_TP_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 1998 to 2024.
Tire sensor 1 temperature FORTWO_TT_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 1998 to 2024.
Tire sensor 2 battery low FORTWO_TPMS_LOWBAT_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 174 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 2 missing FORTWO_TPMS_MISSING_2
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 206 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 2 pressure FORTWO_TP_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 1998 to 2024.
Tire sensor 2 temperature FORTWO_TT_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 1998 to 2024.
Tire sensor 3 battery low FORTWO_TPMS_LOWBAT_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 173 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 3 missing FORTWO_TPMS_MISSING_3
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 205 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 3 pressure FORTWO_TP_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 1998 to 2024.
Tire sensor 3 temperature FORTWO_TT_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 1998 to 2024.
Tire sensor 4 battery low FORTWO_TPMS_LOWBAT_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 172 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 4 missing FORTWO_TPMS_MISSING_4
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 204 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Tire sensor 4 pressure FORTWO_TP_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 1998 to 2024.
Tire sensor 4 temperature FORTWO_TT_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 1998 to 2024.
Trips
Distance at trip start FORTWO_TRIP_START_DIST
- Service 22
DID 01A0 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2024.
Distance, battery controller FORTWO_BMS_ODO
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 72 to 103 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1998 to 2024.
HV battery remaining distance FORTWO_EQA_HV_RANGE
Pelican can show this parameter as the electric range.
- Service 22
DID 6502 - Module
7E5 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000 km
- Unit
- km
In testing for 1998 to 2024.
Time at trip start FORTWO_TRIP_START_TIME
- Service 22
DID 01A2 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 1998 to 2024.
Trip time FORTWO_TRIP_TIME
- Service 22
DID 2104 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 1998 to 2024.