Suzuki XL7

Parameters

The Suzuki XL7 has 128 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air fuel sensor voltage, bank 1 sensor 1 XL7_AFS_VOLTAGE_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2007 to 2009, 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Air fuel sensor voltage, bank 1 sensor 1 XL7_AFS_VOLTAGE_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2007 to 2009, 2020 to 2026.

Battery voltage XL7_BATTERY_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2009, 2020 to 2026.

Climate

Air conditioner feedback XL7_AC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Ambient temperature for A/C XL7_AC_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Communication with air conditioner XL7_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Communication with HV XL7_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Communication with valvematic XL7_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Control

A/C compressor XL7_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Communication with brake XL7_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Cruise control live brake cancel XL7_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Electrical load signal 1 XL7_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Electrical load signal 2 XL7_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Ignition trigger count XL7_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65534
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Neutral position XL7_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Pattern switch XL7_PATTERN_SWITCH_PWR_M

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Power steering XL7_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Shift SW status, drive XL7_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Shift SW status, neutral XL7_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Shift SW status, parking XL7_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Shift SW status, reverse XL7_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Sports mode selection XL7_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Sports shift down XL7_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Sports shift up XL7_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Starter control XL7_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Starter signal XL7_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

TC XL7_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Cruise control

Cancel switch XL7_CC_CANCEL_SWITCH_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Coast switch XL7_CC_LIVE_SET_COAST_SWITCH_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Cruise control indicator XL7_CC_CCS_INDICATOR_M_CPU_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Cruise control ready? XL7_CC_CCS_READY_M_CPU_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2009, 2020 to 2026.

Cruise control speed XL7_CC_S

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2009, 2020 to 2026.

Cruise control speed XL7_CC_VSS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2009, 2020 to 2026.

Cruise control, activated? XL7_CC_CC_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2009, 2020 to 2026.

Cruise control, main switch XL7_CC_MAIN_SW_M_CPU_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Cruise control, on XL7_CC_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Requested driving force XL7_CC_DRIVING_FORCE

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×102255−51.2
Range
-51.2 to 50.8
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Resume/accelerate switch XL7_CC_RES_ACC_SWITCH_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

DTCs

2nd air monitor_avail XL7_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

2nd air monitor_incmpl XL7_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

A/C monitor_avail XL7_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

A/C monitor_incmpl XL7_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Catalyst monitor_avail XL7_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Catalyst monitor_incmpl XL7_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Complete parts monitor_avail XL7_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

EGR/VVT monitor_avail XL7_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

EGR/VVT monitor_incmpl XL7_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

EVAP monitor_avail XL7_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

EVAP monitor_icmpl XL7_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Fuel system monitor_avail XL7_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Heated catalyst monitor_avail XL7_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Heated catalyst monitor_incmpl XL7_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

MIL XL7_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

MIL ON run distance XL7_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2009, 2020 to 2026.

Misfire monitor_avail XL7_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Number of emission DTC XL7_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

O2S heater monitor_avail XL7_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

O2S heater monitor_incmpl XL7_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

O2S monitor_avail XL7_O2S_A_FS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

O2S monitor_incmpl XL7_O2S_A_FS_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Running time from MIL ON XL7_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2007 to 2009, 2020 to 2026.

ECU

Engine module 2128 first value, raw XL7_2128_RAW

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777214
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Electrical

Electric load feedback XL7_ELEC_LOAD_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Engine

Accelerator sensor volt %, 1 XL7_ACCEL_SENS_NO_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Accelerator sensor volt %, 2 XL7_ACCEL_SENS_NO_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

AF lambda, bank 1 sensor 1 XL7_AF_LAMBDA_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Air fuel sensor current, bank 1 sensor 1 XL7_AFS_CURRENT_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val−128
Range
-128 to 127.99 mA
Unit
mA

In testing for 2007 to 2009, 2020 to 2026.

Ambient temperature XL7_AAT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Atmosphere pressure XL7_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2009, 2020 to 2026.

Calculated load_7e0 XL7_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Catalyst temperature B1S1 XL7_CATALYST_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Catalyst temperature B1S2 XL7_CATALYST_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Coolant temp XL7_COOLANT_TEMP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Engine oil temperature XL7_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Engine oil temperature, previous trip XL7_PREV_TRIP_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Engine run time XL7_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2007 to 2009, 2020 to 2026.

Engine start hesitation XL7_ENG_START_HESIT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Engine starting time XL7_ENG_START_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2007 to 2009, 2020 to 2026.

EVAP purge duty XL7_EVAP_PURGE_DUTY

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Idle speed control feedback XL7_ISC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Idle speed control flow XL7_ISC_FLOW

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val×108192
Range
0 to 79.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Idle speed control learning value XL7_ISC_LEARN

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Idle speed control position XL7_ISC_POS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 2007 to 2009, 2020 to 2026.

Ignition advance XL7_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2007 to 2009, 2020 to 2026.

Intake air XL7_INTAKE_AIR

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Intake air temperature, previous trip XL7_PREV_TRIP_IAT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Long FT B1S1 XL7_LONG_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Low revolution control XL7_LOW_RPM_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Low revolution for engine start XL7_LOW_RPM_START

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Manifold absolute pressure XL7_MAP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2009, 2020 to 2026.

Mass air flow XL7_MAF_V2

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2007 to 2009, 2020 to 2026.

Misfire RPM XL7_MISFIRE_RPM_V2

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2007 to 2009, 2020 to 2026.

O2S, bank 1 sensor 2 XL7_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 2007 to 2009, 2020 to 2026.

Short FT B1S1 XL7_SHORT_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Starter count XL7_STARTER_CNT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 33 to 39 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Throttle motor DUTY XL7_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Throttle position XL7_TPS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 2007 to 2009, 2020 to 2026.

Throttle sensor position XL7_THROTTLE_SENSOR_POSITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Throttle sensor volt %, 1 XL7_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Throttle sensor volt %, 2 XL7_THROTTL_SENSOR_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Time after DTC cleared XL7_TIME_AFTER_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2007 to 2009, 2020 to 2026.

Variable valve timing advance fail XL7_VVT_ADV_FAIL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Variable valve timing oil temperature XL7_VVTOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Vehicle load XL7_VEHICLE_LOAD

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Warm-up cycle cleared DTC XL7_WARMUP_CYCLE_CLEARED_DTC

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Misfires

All cylinders misfire count XL7_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 254
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Cylinder #1 misfire count XL7_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 254
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Cylinder #2 misfire count XL7_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 254
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Cylinder #3 misfire count XL7_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 254
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Cylinder #4 misfire count XL7_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 254
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Misfire load XL7_MISFIRE_LOAD_V2

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Misfire margin XL7_MISFIRE_MARGIN_V2

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 2007 to 2009, 2020 to 2026.

Fuel

Immobilizer fuel cut XL7_IMMOB_FUEL_CUT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Target air-fuel ratio XL7_TARGET_AIR_FUEL_RATIO

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Lights

Cruise control stop light switch 1 XL7_CC_STOP_LIGHT_SWITCH_1_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Cruise control stop light switch 2 XL7_CC_STOP_LIGHT_SWITCH_2_ON

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Stop light XL7_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Movement

Engine speed XL7_ENGINE_SPEED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 16383 rpm
Unit
rpm

In testing for 2007 to 2009, 2020 to 2026.

Engine speed, starter off XL7_ENG_SPD_START_OFF

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100128
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2009, 2020 to 2026.

Vehicle speed XL7_VEHICLE_SPEED_V2

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2009, 2020 to 2026.

Transmission

Current gear XL7_GEAR_V3

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Gear XL7_GEAR

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

In testing for 2007 to 2009, 2020 to 2026.

Neutral control XL7_NEUTRAL_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Neutral range status XL7_N_RANGE_STS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Torque converter lock-up XL7_TQC_LOCKUP

Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2009, 2020 to 2026.

Transmission temperature, pan XL7_ATF_PAN_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Transmission temperature, torque converter XL7_ATF_TQC_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Trips

Ambient temperature, previous trip XL7_PREV_TRIP_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2009, 2020 to 2026.

Previous trip distance XL7_PREV_TRIP_DST

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

In testing for 2007 to 2009, 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.