Volkswagen Crafter

Parameters

The Volkswagen Crafter has 613 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage CRAFTER_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1FE1 = 8161 → 81611000+4 = 12.161 V

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal, sensor 1 voltage CRAFTER_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2006 to 2026.

Accelerator pedal, sensor 2 voltage CRAFTER_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2006 to 2026.

Battery charge level CRAFTER_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x54 = 84 → 84 %

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery current CRAFTER_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000 to 1000 A
Unit
A

0x00002DB0 = 11696 → 116961000 = 11.696 A

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery internal resistance CRAFTER_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x17 = 23 → 23×20100 = 4.6

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery internal resistance, raw CRAFTER_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2006 to 2026.

Battery temperature CRAFTER_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x46 = 70 → 70−40 = 30 °C

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery voltage CRAFTER_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1FE1 = 8161 → 81611000+4 = 12.161 V

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery voltage CRAFTER_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2006 to 2026.

Battery voltage at rest CRAFTER_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x24 = 36 → 3610+9 = 12.6 V

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Battery voltage variant CRAFTER_PQ35_BAT_V_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2006 to 2026.

Boost pressure CRAFTER_PQ35_CHG_P

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2006 to 2026.

Calculated nitrogen oxide concentration behind turbocharger CRAFTER_MQB_NOX_CONC_BEHIND_TURBO

  • Service 22DID 1526
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2006 to 2026.

Charge air pressure CRAFTER_PQ35_CHG_AIR_P

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Charge air pressure: actual CRAFTER_PQ35_CHARGE_AIR_P_ACTUAL

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2006 to 2026.

Charge air pressure: specified CRAFTER_PQ35_CHARGE_AIR_P_SPECIFIED

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2006 to 2026.

Charge air temp at the turbocharger outlet, calculated CRAFTER_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED

  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Charge limit overcharge protection CRAFTER_PQ35_CHG_LIM_OVER

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Charge pressure actuator, maximum sensor voltage CRAFTER_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2006 to 2026.

Charge pressure regulator, lower threshold adaptation CRAFTER_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2006 to 2026.

Charge pressure regulator, upper threshold adaptation CRAFTER_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2006 to 2026.

Control module voltage CRAFTER_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2EF0 = 12016 → 120161000 = 12.016 V

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Exhaust gas recirculation valve 1, B1, mass current: specified value CRAFTER_MQB_EGR_VALVE_1_B1_MASS_I_SPEC

  • Service 22DID 1813
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2006 to 2026.

Exhaust gas recirculation valve 2, B1, mass current: specified value CRAFTER_MQB_EGR_VALVE_2_B1_MASS_I_SPEC

  • Service 22DID 1814
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2006 to 2026.

High voltage battery energy information CRAFTER_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2006 to 2026.

High voltage battery energy information CRAFTER_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2006 to 2026.

HV battery maximum power CRAFTER_HVBAT_PWR_MAX

  • Service 22DID 1502
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2006 to 2026.

HV battery temperature load CRAFTER_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Start/stop battery target voltage CRAFTER_SSB_VTConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

0x10 = 16 → 1610+10.6 = 12.2 V

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Start/stop battery total charge CRAFTER_SSB_TOTAL_CHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00003161 = 12641 → 1264110 = 1,264.1 Ah

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Start/stop battery total discharge CRAFTER_SSB_TOTAL_DISCHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x000030BF = 12479 → 1247910 = 1,247.9 Ah

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Turbocharger inlet pressure corrected value CRAFTER_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Usable battery charge CRAFTER_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x2C = 44 → 44 Ah

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Climate

Air conditioning compressor shutdown requirement CRAFTER_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Air conditioning compressor torque CRAFTER_PQ35_AC_COMP_TRQ

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Ambient air temperature CRAFTER_AAT_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2026.

Barometric pressure CRAFTER_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2006 to 2026.

Clocks

Time since engine start CRAFTER_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x2695 = 9877 → 9,877 s

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Control

Accelerator pedal release detection threshold voltage CRAFTER_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2006 to 2026.

Brake booster low pressure, actual CRAFTER_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 2006 to 2026.

Brake booster pressure CRAFTER_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2006 to 2026.

Brake booster raw pressure CRAFTER_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2006 to 2026.

Brake pedal position CRAFTER_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Brake pressure CRAFTER_MQB_TCM_BRAKE_P

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Brake pressure CRAFTER_PQ35_BRAKE_P

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Brake system vacuum pump active CRAFTER_BRAKE_SYSTEM_VACUUM

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Downshift point adaptation voltage CRAFTER_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2006 to 2026.

Requested brake torque, auxiliary system CRAFTER_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2006 to 2026.

CRAFTER_PQ35_TIME_LAST

Time since last regeneration CRAFTER_PQ35_TIME_LAST_REGEN

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10066666667
Range
0 to 0.426 min
Unit
min

In testing for 2006 to 2026.

Drivetrain

Driver torque requested #1 CRAFTER_ENG_TRQ_REQ_1

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2006 to 2026.

Driver torque requested #2 CRAFTER_ENG_TRQ_REQ_2

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2006 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CRAFTER_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x11BD = 4541 → 4,541 km

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Distance traveled while mil was activated CRAFTER_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Number of warm-ups since diagnostic trouble codes cleared CRAFTER_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x81 = 129 → 129

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

ECU

Torque converter slip CRAFTER_TORQUE_CONVERTER_SLIP

  • Service 22DID 2131
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Engine

A/C compressor torque CRAFTER_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

A/C refrigerant pressure CRAFTER_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2006 to 2026.

Adaptation of throttle valve CRAFTER_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Air conditioning compressor pressure, linear raw value CRAFTER_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2006 to 2026.

Air filling CRAFTER_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Air leakage CRAFTER_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Air mass meter 1 CRAFTER_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2006 to 2026.

Ambient air pressure CRAFTER_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 2006 to 2026.

Ambient air temperature CRAFTER_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x7D = 125 → 1252−50 = 12.5 °C

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Ambient air temperature, v1 CRAFTER_AAT_V1

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2006 to 2026.

Analysis, clutch 1, maximum temperature CRAFTER_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2006 to 2026.

Analysis, clutch 2, maximum temperature CRAFTER_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2006 to 2026.

Automatic engine starts counter CRAFTER_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Automatic transmission fluid temperature, lifetime max CRAFTER_ATF_MAX

  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2026.

Avg. injection time CRAFTER_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

In testing for 2006 to 2026.

Boost press before throttle: calculated actual value CRAFTER_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2006 to 2026.

Boost pressure actuator, commanded duty CRAFTER_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 2006 to 2026.

Boost pressure, actual CRAFTER_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Boost regulator feedback CRAFTER_BOOST_REGULATOR_FEEDBACK

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Calculated oil temperature CRAFTER_PQ35_CALCULATED_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2026.

Camshaft adaptation, counter due to knock CRAFTER_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Camshaft adaptation, exhaust bank 1, phase position CRAFTER_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Camshaft adaptation, intake bank 1, phase position CRAFTER_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Camshaft adaptation, intake deviation CRAFTER_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2006 to 2026.

Camshaft adjustment, exhaust bank 1, actual value CRAFTER_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2006 to 2026.

Camshaft adjustment, exhaust bank 1, specified value CRAFTER_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2006 to 2026.

Camshaft adjustment, exhaust, actual value CRAFTER_CAM_ADJ_EXH_ACT

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2006 to 2026.

Camshaft adjustment, intake bank 1, actual value CRAFTER_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2006 to 2026.

Camshaft adjustment, intake bank 1, specified value CRAFTER_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2006 to 2026.

Camshaft end position CRAFTER_PQ35_CAMS_END

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2006 to 2026.

Camshaft position, deviation from the base position CRAFTER_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2006 to 2026.

Camshaft start position CRAFTER_PQ35_CAMS_START

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2006 to 2026.

Cat. converter oxygen storage capacity measured CRAFTER_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Catalyst temperature, calculated CRAFTER_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2006 to 2026.

Centrifugal oil temperature CRAFTER_PQ35_CENTRIFUGAL_OIL_T

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2006 to 2026.

Chain elongation inlet, mileage at last adaptation CRAFTER_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006 to 2026.

Chain elongation outlet, mileage at last adaptation CRAFTER_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 CRAFTER_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Chain elongation, no of valid initial values, intake bank 1 CRAFTER_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Clutch #1 maximum temperature CRAFTER_PQ35_CLUTCH_1_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2006 to 2026.

Clutch #2 maximum temperature CRAFTER_PQ35_CLUTCH_2_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2006 to 2026.

Clutch 1 temperature CRAFTER_PQ35_CLUTCH_1_T

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2006 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity CRAFTER_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 1 temperature protection warning 1 quantity CRAFTER_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 1 temperature protection warning 2 quantity CRAFTER_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 2 temperature CRAFTER_PQ35_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2006 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity CRAFTER_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 2 temperature protection warning 1 quantity CRAFTER_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 2 temperature protection warning 2 quantity CRAFTER_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch center central plate temperature CRAFTER_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2006 to 2026.

Commanded crankshaft torque CRAFTER_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Compression test cylinder 1 CRAFTER_PQ35_COMPRESSION_TEST_CYL_1

  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Compression test cylinder 2 CRAFTER_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Compression test cylinder 3 CRAFTER_PQ35_COMP_TEST_CYL_3

  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Control module temperature CRAFTER_MQB_TCM_ECU_T

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2006 to 2026.

Converter loss torque CRAFTER_MQB_TCM_CONVERTER_LOSS_TORQUE

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Coolant circulation pump, control CRAFTER_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Coolant fan 1 duty cycle CRAFTER_PQ35_COOL_FAN_1_DUTY

  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Coolant fan 1, activation CRAFTER_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Coolant fan 2 duty cycle CRAFTER_PQ35_COOL_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Coolant fan, requested by A/C CRAFTER_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2006 to 2026.

Coolant temperature at engine start CRAFTER_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Coolant temperature at radiator outlet CRAFTER_COOLANT_T

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 300 °C
Unit
°C

In testing for 2006 to 2026.

Coolant temperature at radiator outlet v.1 CRAFTER_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Coolant temperature modeled value CRAFTER_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Correction values for main pressure adaptation CRAFTER_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Crankshaft rotation angle when closing the quantity control valve CRAFTER_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2006 to 2026.

Cylinder head temperature CRAFTER_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 600 °F
Unit
°F

In testing for 2006 to 2026.

Diesel particulate filter air pressure sensor, raw CRAFTER_MQB_DPF_AIR_P_SENSOR_RAW_VALUE

  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter differential pressure offset CRAFTER_PQ35_DPF_DIFF_P_OFFSET

  • Service 22DID 10F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter differential pressure variant 2 CRAFTER_PQ35_DPF_DIFF_P_2

  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter differential pressure, dynamic offset CRAFTER_MQB_DPF_DIFF_P_DYNAMIC_OFFSET

  • Service 22DID 15B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter exhaust gas flow volume CRAFTER_MQB_DPF_EXH_VOL

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter inlet temperature CRAFTER_PQ35_DPF_IN_T

  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Diesel particulate filter oil ash mass CRAFTER_MQB_DPF_OIL_ASH_MASS

  • Service 22DID 1ABD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.001192110000
Range
0 to 512
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter outlet temperature CRAFTER_PQ35_DPF_OUT_T

  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Diesel particulate filter surface temperature CRAFTER_DPF_SFC_T

  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 1200 °C
Unit
°C

In testing for 2006 to 2026.

Differential pressure CRAFTER_PQ35_DIFF_P

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Drive motor current CRAFTER_MOTOR_I

  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2006 to 2026.

Drive motor torque CRAFTER_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2006 to 2026.

Driver demand torque CRAFTER_MQB_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Ea888b boost pressure control, adaptation value 0 CRAFTER_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2006 to 2026.

Ea888b boost pressure control, adaptation value 1 CRAFTER_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2006 to 2026.

Ea888b boost pressure control, adaptation value 2 CRAFTER_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2006 to 2026.

Ea888b boost pressure control, adaptation value 3 CRAFTER_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2006 to 2026.

Ea888b boost pressure regulator, commanded CRAFTER_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Early ignition counter, cylinder 1 CRAFTER_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, cylinder 2 CRAFTER_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, cylinder 3 CRAFTER_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, cylinder 4 CRAFTER_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, total, cylinder 1 CRAFTER_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, total, cylinder 2 CRAFTER_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, total, cylinder 3 CRAFTER_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Early ignition counter, total, cylinder 4 CRAFTER_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Effective injection duration CRAFTER_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2006 to 2026.

Electric additional coolant pump control, high circle CRAFTER_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2006 to 2026.

Energy content CRAFTER_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2006 to 2026.

Engine control module temperature CRAFTER_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x00B6 = 182 → 18210 = 18.2 °C

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Engine oil level CRAFTER_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2006 to 2026.

Engine oil sump temperature CRAFTER_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2006 to 2026.

Engine outlet coolant temperature calculated CRAFTER_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Engine start quantity CRAFTER_PQ35_ENG_START_QTY

  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Engine torque CRAFTER_ENGINE_TORQUE

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Engine torque CRAFTER_MQB_TCM_ENG_TORQUE

  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006 to 2026.

Engine torque CRAFTER_MQB_TCM_ENGINE_TORQUE

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Engine torque CRAFTER_PQ35_ENG_TRQ

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Engine torque limitation CRAFTER_MQB_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Engine torque loss CRAFTER_MQB_TCM_ENGINE_TORQUE_LOSS

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Exhaust camshaft, adaptation bias CRAFTER_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2006 to 2026.

Exhaust camshaft, adaptation sensor tolerance CRAFTER_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2006 to 2026.

Exhaust gas recirculation valve 2 bank 1 mass flow CRAFTER_MQB_EGR_VALVE_2_B1_FLOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2006 to 2026.

Exhaust gas recirculation valve duty CRAFTER_PQ35_EGR_DUTY

  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Exhaust gas temperature CRAFTER_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2006 to 2026.

Exhaust gas temperature before catalyst CRAFTER_EXHAUST_GAS_T_BEFORE_CATALYST

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2006 to 2026.

Exhaust gas temperature sensor 1 CRAFTER_PQ35_EXH_GAS_T_1

  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Exhaust gas temperature sensor 2 CRAFTER_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error CRAFTER_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Field limit value CRAFTER_PQ35_FIELD_LIM

  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Fuel temperature CRAFTER_PQ35_FUEL_T

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 300 °C
Unit
°C

In testing for 2006 to 2026.

Generator current CRAFTER_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2006 to 2026.

Generator load CRAFTER_PQ35_GEN_LOAD

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Generator load normalized value CRAFTER_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Generator load signal CRAFTER_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Generator performance CRAFTER_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2006 to 2026.

Generator torque request CRAFTER_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Glow plug preheat time CRAFTER_PQ35_PREHEAT_T

  • Service 22DID 111F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 ms
Unit
ms

In testing for 2006 to 2026.

Heater circulation pump, nominal value CRAFTER_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Height correction CRAFTER_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2006 to 2026.

High pressure control, adaptation CRAFTER_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2006 to 2026.

IGA_CYL_KNK, 0 CRAFTER_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

IGA_CYL_KNK, 1 CRAFTER_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

IGA_CYL_KNK, 2 CRAFTER_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

IGA_CYL_KNK, 3 CRAFTER_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

IGA_IGC, 3 CRAFTER_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2006 to 2026.

Ignition timing angle retard, cylinder 4 CRAFTER_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2006 to 2026.

Injection amount deviation cylinder 1 CRAFTER_PQ35_INJ_DEV_CYL_1

  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Injection amount deviation cylinder 2 CRAFTER_PQ35_INJ_DEV_CYL_2

  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Injection amount deviation cylinder 3 CRAFTER_PQ35_INJ_DEV_CYL_3

  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Injection amount deviation cylinder 4 CRAFTER_PQ35_INJ_DEV_CYL_4

  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Injector 1 rail pressure calibration point 1 CRAFTER_PQ35_INJ_1_RAIL_P_1

  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 1 rail pressure calibration point 2 CRAFTER_PQ35_INJ_1_RAIL_P_2

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 1 rail pressure calibration point 3 CRAFTER_PQ35_INJ_1_RAIL_P_3

  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 2 rail pressure calibration point 1 CRAFTER_PQ35_INJ_2_RAIL_P_1

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 2 rail pressure calibration point 2 CRAFTER_PQ35_INJ_2_RAIL_P_2

  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 2 rail pressure calibration point 3 CRAFTER_PQ35_INJ_2_RAIL_P_3

  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 2: rail pressure calibration point 1 CRAFTER_INJ_2_RAIL_P_CAL_PT_1_146E

  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Injector 2: rail pressure calibration point 2 CRAFTER_INJ_2_RAIL_P_CAL_PT_2_1474

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Injector 2: rail pressure calibration point 3 CRAFTER_INJ_2_RAIL_P_CAL_PT_3_147A

  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Injector 3 rail pressure calibration point 1 CRAFTER_PQ35_INJ_3_RAIL_P_1

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 3 rail pressure calibration point 2 CRAFTER_PQ35_INJ_3_RAIL_P_2

  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 3 rail pressure calibration point 3 CRAFTER_PQ35_INJ_3_RAIL_P_3

  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 4 rail pressure calibration point 2 CRAFTER_PQ35_INJ_4_RAIL_P_2

  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 4 rail pressure calibration point 3 CRAFTER_PQ35_INJ_4_RAIL_P_3

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2006 to 2026.

Injector 7: rail pressure calibration point 1 CRAFTER_INJ_7_RAIL_P_CAL_PT_1

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Injector 7: rail pressure calibration point 2 CRAFTER_INJ_7_RAIL_P_CAL_PT_2

  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Injector 7: rail pressure calibration point 3 CRAFTER_INJ_7_RAIL_P_CAL_PT_3

  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2006 to 2026.

Inlet flaps - actual value CRAFTER_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Inlet flaps - requested value CRAFTER_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Intake air temperature in intake manifold CRAFTER_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2006 to 2026.

Intake air temperature raw value CRAFTER_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Intake camshaft adaptation unit 1 phase length CRAFTER_PQ35_CAMS_ADAPT_PHASE_1

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Intake camshaft signal edge position adapted edge 2 CRAFTER_PQ35_CAMS_EDGE_POS_2

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2006 to 2026.

Intake camshaft signal edge position adapted edge 3 CRAFTER_PQ35_CAMS_EDGE_POS_3

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2006 to 2026.

Intake camshaft signal edge position adapted edge 4 CRAFTER_PQ35_CAMS_EDGE_POS_4

  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2006 to 2026.

Intake camshaft, adaptation bias CRAFTER_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2006 to 2026.

Intake camshaft, adaptation sensor tolerance CRAFTER_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2006 to 2026.

Intake manifold pressure calculated CRAFTER_MQB_INT_MAN_P

  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Intake manifold pressure, commanded CRAFTER_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Intake manifold pressure, corrected CRAFTER_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Intake model air mass flow filtered value CRAFTER_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Intake phase deviation, actual value CRAFTER_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2006 to 2026.

Integrated mass of air since engine start CRAFTER_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2006 to 2026.

Integrated mass of air since the first engine start CRAFTER_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2006 to 2026.

Intercooler air output temperature CRAFTER_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Kick down CRAFTER_MQB_TCM_KICK_DOWN

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Kilometers driven since last event on K1 CRAFTER_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2006 to 2026.

Kilometers driven since last event on K2 CRAFTER_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2006 to 2026.

Knock retard 2 CRAFTER_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2006 to 2026.

Knock sensor, cylinder 1 CRAFTER_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2006 to 2026.

Knock sensor, cylinder 2 CRAFTER_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2006 to 2026.

Knock sensor, cylinder 3 CRAFTER_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2006 to 2026.

Knock sensor, cylinder 4 CRAFTER_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2006 to 2026.

Lambda output value CRAFTER_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2006 to 2026.

Launch control counter, variant 1 CRAFTER_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Long term fuel trim at idle, direct injection CRAFTER_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2006 to 2026.

Long term fuel trim at idle, port injection CRAFTER_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2006 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation CRAFTER_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Main cat oxygen storage capacity age correction factor CRAFTER_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2006 to 2026.

Main injection duration CRAFTER_PQ35_MAIN_INJ_DURATION

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Main injection start position CRAFTER_PQ35_MAIN_INJ_START

  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Manifold absolute pressure, raw value CRAFTER_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Manual engine starts counter CRAFTER_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Mass air flow through throttle CRAFTER_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Mass air flow, commanded CRAFTER_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Mass airflow sensor 1 bank 1 raw value CRAFTER_MQB_MAF_1_B1_RAW

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2006 to 2026.

Maximum oil level for the service interval CRAFTER_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Mean engine air mass CRAFTER_PQ35_MEAN_AIR_MASS

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968
Unit
Raw value

In testing for 2006 to 2026.

Mean injection quantity CRAFTER_MEAN_INJ_QUANTITY

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Minimum oil level for the service interval CRAFTER_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Misfires / 1000 revolutions, cylinder 1 CRAFTER_MISFIRES_1000REV_C1

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires / 1000 revolutions, cylinder 2 CRAFTER_MISFIRES_1000REV_C2

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires / 1000 revolutions, cylinder 3 CRAFTER_MISFIRES_1000REV_C3

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires / 1000 revolutions, cylinder 4 CRAFTER_MISFIRES_1000REV_C4

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires per 1000 revolutions 4 CRAFTER_MIS_PER_1000_REVOLUTIONS_4_7E0

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires total CRAFTER_MISFIRES_TOTAL

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires, cylinder 1 CRAFTER_MISFIRES_C1

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Misfires, cylinder 3 CRAFTER_MISFIRES_C3

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

N_32 CRAFTER_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2006 to 2026.

Number of injections CRAFTER_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

NV energy requirement CRAFTER_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2006 to 2026.

Oil ash residue CRAFTER_PQ35_OIL_ASH_RESIDUE

  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2006 to 2026.

Oil dynamic average measurement CRAFTER_PQ35_OIL_DYN_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Oil fill level CRAFTER_PQ35_OIL_FILL_LEVEL

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2006 to 2026.

Oil last dynamic measurement CRAFTER_PQ35_OIL_DYN_LAST

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Oil level, average dynamic value CRAFTER_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Oil level, static measured CRAFTER_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2006 to 2026.

Oil pressure actual CRAFTER_MQB_TCM_EOP_ACTUAL

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

In testing for 2006 to 2026.

Oil pressure actual current CRAFTER_MQB_TCM_EOP_ACTUAL_I

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2006 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status CRAFTER_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Oil pressure valve switch, control CRAFTER_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Oil temp 2 CRAFTER_PQ35_ENGINE_OIL_T_2

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Oil thermal wear CRAFTER_DASH_OIL_THERMAL_WEAR

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2026.

Open cam shaft angle at quantity control valve CRAFTER_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2006 to 2026.

Outside temperature CRAFTER_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2006 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature CRAFTER_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2006 to 2026.

Oxygen sensor 1 bank 1 lambda value CRAFTER_PQ35_O2_SEN_1_LAMBDA

  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Number

In testing for 2006 to 2026.

Pilot injection 1 duration CRAFTER_PQ35_PRE_INJ_1_DURATION

  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Pilot injection 1 start position CRAFTER_PQ35_PRE_INJ_1_START

  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Pilot injection 2 duration CRAFTER_PQ35_PRE_INJ_2_DURATION

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Pilot injection 2 start CRAFTER_PQ35_PRE_INJ_2_START

  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Piston cooling nozzles, control CRAFTER_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Post injection 1: quantity specified value CRAFTER_PQ35_POST_INJ_1_QTY_SPEC

  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Post injection 2: quantity specified value CRAFTER_PQ35_POST_INJ_2_QTY_SPEC

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Post injection 3: quantity specified value CRAFTER_PQ35_POST_INJ_3_QTY_SPEC

  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Post-injection 1 duration CRAFTER_PQ35_POST_INJ_1_DURATION

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Post-injection 1 start position CRAFTER_PQ35_POST_INJ_1_START

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Post-injection 2 duration CRAFTER_PQ35_POST_INJ_2_DURATION

  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Post-injection 2 start position CRAFTER_PQ35_POST_INJ_2_START

  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Post-injection 3 activation duration CRAFTER_PQ35_POST_INJ_3_ACTIVATION_DURATION

  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2006 to 2026.

Post-injection 3 start position CRAFTER_PQ35_POST_INJ_3_START

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2006 to 2026.

Pressure before throttle valve - actual value CRAFTER_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2006 to 2026.

Pressure before throttle valve - sensor measured CRAFTER_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2006 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 CRAFTER_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2006 to 2026.

Radiator outlet coolant temperature commanded CRAFTER_PQ35_RAD_COOL_T_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2006 to 2026.

Radiator output coolant temp: actual CRAFTER_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 300 °C
Unit
°C

In testing for 2006 to 2026.

Rated drive torque CRAFTER_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2006 to 2026.

Reached maximum temperature CRAFTER_PQ35_REACHED_MAXIMUM_T

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2006 to 2026.

Rear cat converter temperature, main catalytic converter model value CRAFTER_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2006 to 2026.

Regulation factor total CRAFTER_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2006 to 2026.

Relative load value CRAFTER_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 2006 to 2026.

Requested torque, amount for auxiliary units CRAFTER_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Result of crankcase ventilation test, fail CRAFTER_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Result of crankcase ventilation test, successful CRAFTER_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

SEG_AD_MMV_ER_H, 2 CRAFTER_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2006 to 2026.

SEG_AD_MMV_ER_L, 3 CRAFTER_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2006 to 2026.

Service limit value CRAFTER_PQ35_SRV_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Smoke limit CRAFTER_PQ35_LIM_SMOKE

  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Spark efficiency deviation at part load CRAFTER_SPARK_EFF_DEV

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×78.1100
Range
0 to 199.14 %
Unit
%

In testing for 2006 to 2026.

Stop signal switch CRAFTER_MQB_TCM_STOP_SIGNAL_SWITCH

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Tank fill level diagnostic reference value CRAFTER_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2006 to 2026.

TCO_1_ST CRAFTER_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2026.

TCO_1_SYS CRAFTER_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2026.

Throttle regulator nominal value CRAFTER_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Throttle valve adapter position CRAFTER_PQ35_THROT_VALVE_ADAPT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Timing angle retardation cylinder 1 CRAFTER_PQ35_TIMING_ANGLE_RETARDATION_CYL_1

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

Timing angle retardation cylinder 2 CRAFTER_PQ35_TIMING_ANGLE_RETARDATION_CYL_2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

Timing angle retardation cylinder 3 CRAFTER_PQ35_TIMING_ANGLE_RETARDATION_CYL_3

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

Timing angle retardation cylinder 4 CRAFTER_PQ35_TIMING_ANGLE_RETARDATION_CYL_4

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2006 to 2026.

Timing deviation after chain replacement, exhaust bank 1 CRAFTER_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Timing deviation after chain replacement, intake bank 1 CRAFTER_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Timing deviation after other repairs, intake bank 1 CRAFTER_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Timing deviation after other repairs, intake bank 1 CRAFTER_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Timing deviation current value exhaust bank 1 CRAFTER_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Timing deviation current value intake bank 1 CRAFTER_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2006 to 2026.

Torque converter: torque loss CRAFTER_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque increase request from ESP CRAFTER_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque limit CRAFTER_PQ35_LIM_TRQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque limitation CRAFTER_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque limitation CRAFTER_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque loss adaptation at idle CRAFTER_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque loss adaptation, A/C compressor CRAFTER_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque reduction due to exhaust temperature CRAFTER_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.276
Unit
Number

In testing for 2006 to 2026.

Torque reduction request from ESP CRAFTER_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2006 to 2026.

Total mass of gasoline and ethyl alcohol in oil CRAFTER_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 2006 to 2026.

Transmission fluid temperature, calculated CRAFTER_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2026.

Transmission fluid temperature, modeled maximum reached CRAFTER_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2006 to 2026.

Turbine actuator 1 bank 1 activation CRAFTER_PQ35_TURB_ACT_1_B1

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Turbine actuator 1 bank 1: activation CRAFTER_ACT

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation CRAFTER_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation CRAFTER_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Valve lift system, result of last switch, intake CRAFTER_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Valve lift system, valve lift, exhaust CRAFTER_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Valve lift system, valve lift, intake CRAFTER_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Valve timing, the difference between the, actual and the set angle CRAFTER_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 2006 to 2026.

Variable valve timing, intake, bank 1, regulation CRAFTER_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Variable valve timing, intake, bank 1, switch on CRAFTER_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Wear index CRAFTER_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2006 to 2026.

DPF

Diesel particulate filter ash load limit CRAFTER_MQB_DPF_ASH_LOAD_LIMIT

  • Service 22DID 1ABF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×78.12510000
Range
0 to 511.992
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter diff pressure: raw value 1 CRAFTER_MQB_DPF_DIFF_P_RAW_VALUE_1

  • Service 22DID 269A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter diff pressure: raw value 2 CRAFTER_MQB_DPF_DIFF_P_RAW_VALUE_2

  • Service 22DID 269B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter field regeneration lock status CRAFTER_PQ35_DPF_FIELD_REGEN_LOCK

  • Service 22DID 11C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter field regeneration request CRAFTER_MQB_DPF_FIELD_REGEN_REQUEST

  • Service 22DID 1AC2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter fuel consumption since last regeneration CRAFTER_MQB_DPF_FUEL_CONSUMPTION_SINCE_LAST_REGEN

  • Service 22DID 1AC1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 L
Unit
L

In testing for 2006 to 2026.

Diesel particulate filter fuel consumption since last regeneration CRAFTER_PQ35_DPF_FUEL_CON_REGEN

  • Service 22DID 115A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2006 to 2026.

Diesel particulate filter inlet lambda value CRAFTER_MQB_DPF_INLET_LAMBDA_VALUE

  • Service 22DID 1AD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter regeneration level current CRAFTER_MQB_DPF_REGEN_LEVEL_I

  • Service 22DID 1AD3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter regeneration release requirement CRAFTER_MQB_DPF_REGEN_RELEASE_REQUIREMENT

  • Service 22DID 1AD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter regeneration status CRAFTER_MQB_DPF_REGEN_STATUS

  • Service 22DID 1AD4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter regeneration time counter CRAFTER_MQB_DPF_REGEN_TIME_COUNTER

  • Service 22DID 1AC0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×640010000
Range
0 to 41942.4 s
Unit
s

In testing for 2006 to 2026.

Diesel particulate filter service regeneration current duration CRAFTER_MQB_DPF_SERVICE_REGEN_I_DURATION

  • Service 22DID 1AC4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×640010000
Range
0 to 41942.4 s
Unit
s

In testing for 2006 to 2026.

Diesel particulate filter soot mass calculated CRAFTER_MQB_DPF_SOOT_MASS_CALCULATED

  • Service 22DID 2609
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter soot mass measured CRAFTER_MQB_DPF_SOOT_MASS_MEASURED

  • Service 22DID 1ABE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter statistics average drive cycle time during charge cycle CRAFTER_MQB_DPF_STATISTICS_AVERAGE_DRIVE_CYCLE_TIME_DURING_CHARGE_CYCLE

  • Service 22DID 1ACC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1600100
Range
0 to 4080 s
Unit
s

In testing for 2006 to 2026.

Diesel particulate filter statistics error status CRAFTER_MQB_DPF_STATISTICS_ERROR_STATUS

  • Service 22DID 1ACA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics exhaust temperature regulation average value CRAFTER_MQB_DPF_STATISTICS_EXHAUST_T_REGULATION_AVERAGE_VALUE

  • Service 22DID 1AC7
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.98127
Range
-1.99 to 1.98
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics number of interrupted regenerations CRAFTER_MQB_DPF_STATISTICS_NUMBER_INTERRUPTED_REGENS

  • Service 22DID 1AC9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics regeneration blocked status CRAFTER_MQB_DPF_STATISTICS_REGEN_BLOCKED_STATUS

  • Service 22DID 1AC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics regeneration request CRAFTER_MQB_DPF_STATISTICS_REGEN_REQUEST

  • Service 22DID 1AC5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics regeneration time CRAFTER_MQB_DPF_STATISTICS_REGEN_TIME

  • Service 22DID 1ACD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6400100
Range
0 to 16320 s
Unit
s

In testing for 2006 to 2026.

Diesel particulate filter statistics regeneration time slice not possible in charge cycle CRAFTER_MQB_DPF_STATISTICS_REGEN_TIME_SLICE_NOT_POSS_IN_CHARGE_CYCLE

  • Service 22DID 1ACE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.498255
Range
0 to 0.498
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter statistics route in charge cycle CRAFTER_MQB_DPF_STATISTICS_ROUTE_IN_CHARGE_CYCLE

  • Service 22DID 1ACB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×800100
Range
0 to 2040 km
Unit
km

In testing for 2006 to 2026.

Diesel particulate filter time since last regeneration CRAFTER_MQB_DPF_TIME_SINCE_LAST_REGEN

  • Service 22DID 1AC3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×127.99865535
Range
0 to 127.998 h
Unit
h

In testing for 2006 to 2026.

Diesel particulate filter unburned fuel calculated CRAFTER_MQB_DPF_UNBURNED_FUEL_CALCULATED

  • Service 22DID 18BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2006 to 2026.

Diesel particulate filter, charge limit for service regeneration while driving CRAFTER_MQB_DPF_CHARGE_LIMIT_SERVICE_REGEN_WHILE_DRIVING

  • Service 22DID 1ABB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter, charge limit over-charge CRAFTER_MQB_DPF_CHARGE_LIMIT_OVER_CHARGE

  • Service 22DID 1ABC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

Diesel particulate filter, distance since last regeneration CRAFTER_MQB_DPF_DISTANCE_SINCE_LAST_REGEN

  • Service 22DID 1ABA
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2006 to 2026.

Regeneration duration CRAFTER_PQ35_REGEN_DUR

  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2006 to 2026.

Service regeneration status CRAFTER_PQ35_SRV_REGEN_STAT

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Soot index CRAFTER_PQ35_SOOT_IDX

  • Service 22DID 1354
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2006 to 2026.

Soot mass measured CRAFTER_PQ35_SOOT_MASS_MEAS

  • Service 22DID 114E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2006 to 2026.

EGR

Exhaust gas recirculation 2: filter press loss, modeled CRAFTER_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2006 to 2026.

Exhaust gas recirculation 2: filter press loss, simulated CRAFTER_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2006 to 2026.

High press EGR closing v1 CRAFTER_PQ35_HIGH_P_EGR_CLOSING_VAR_1

  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Fluids

Automatic transmission fluid temperature CRAFTER_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x78 = 120 → 120−40 = 80 °C

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Fuel

Average fuel consumption CRAFTER_DASH_AVG_FUEL_CONS

  • Service 22DID 2299
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2006 to 2026.

Fuel consumption CRAFTER_FUEL_CONS

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2006 to 2026.

Fuel consumption - actual drive cycle CRAFTER_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2006 to 2026.

Fuel filter: water level sensor 1 CRAFTER_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1

  • Service 22DID 197C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Fuel flow rate CRAFTER_PQ35_FUEL_FLOW

Pelican can show this parameter as the fuel rate.

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2006 to 2026.

Fuel level CRAFTER_PQ35_FUEL_LEVEL_7E0_2206

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2006 to 2026.

Fuel level CRAFTER_PQ35_FUEL_LVL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2006 to 2026.

Fuel level input % CRAFTER_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Fuel level input, v1 CRAFTER_FUEL_LEVEL_INPUT_V1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2006 to 2026.

Fuel level variant CRAFTER_PQ35_FUEL_LVL_2

  • Service 22DID 100C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2006 to 2026.

Fuel mix correction coefficient CRAFTER_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2006 to 2026.

Fuel pressure regulator position CRAFTER_PQ35_FUEL_P_REG

  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Fuel pressure regulator valve: specified value rail pressure CRAFTER_SPEC_VALUE_RAIL_P

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2006 to 2026.

Fuel pump adaptation CRAFTER_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2006 to 2026.

Fuel pump, commanded duty CRAFTER_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 2006 to 2026.

Fuel rate difference, injector/sensor CRAFTER_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2006 to 2026.

Fuel temperature CRAFTER_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2006 to 2026.

High fuel pressure control deviation CRAFTER_HIGH_FUEL_P_CONTROL_DEVIATION

  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2006 to 2026.

High fuel pressure, actual CRAFTER_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2006 to 2026.

High fuel pressure, commanded CRAFTER_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2006 to 2026.

High fuel pressure, regulation error CRAFTER_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2006 to 2026.

High pressure fuel pressure actual CRAFTER_PQ35_FUEL_P_HIGH

  • Service 22DID 1169
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2006 to 2026.

High pressure fuel pressure commanded CRAFTER_PQ35_FUEL_P_HIGH_CMD

  • Service 22DID 116A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2006 to 2026.

Long term fuel trim bank 1 CRAFTER_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2006 to 2026.

Long term fuel trim direct injection at load CRAFTER_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2006 to 2026.

Long term fuel trim port injection at load CRAFTER_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2006 to 2026.

Low fuel pressure, actual CRAFTER_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2006 to 2026.

Low fuel pressure, commanded CRAFTER_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2006 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual CRAFTER_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2006 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum CRAFTER_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2006 to 2026.

Short term fuel trim bank 1 CRAFTER_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2006 to 2026.

Movement

Acceleration CRAFTER_ACCELERATION

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Acceleration CRAFTER_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Accelerator pedal limit CRAFTER_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Accelerator pedal position 1 CRAFTER_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Accelerator pedal position 2 CRAFTER_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Accelerator pedal sensor 1 CRAFTER_PQ35_ACCEL_PED_1

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2006 to 2026.

Accelerator pedal sensor 2 CRAFTER_PQ35_ACCEL_PED_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2006 to 2026.

Accelerator pedal torque limit CRAFTER_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Camshaft speed CRAFTER_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2026.

Camshaft speed CRAFTER_PQ35_CAMS_SPD

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.3
Range
-9830.4 to 9830.1 rpm
Unit
rpm

In testing for 2006 to 2026.

Crankshaft speed CRAFTER_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Engine RPM CRAFTER_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2006 to 2026.

Engine RPM at idle required CRAFTER_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Front right wheel speed CRAFTER_TIRE_FR_SPD_V3

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2023, 2025 to 2026. Not supported for 2024.

Injection speed injector 0 CRAFTER_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2026.

Lateral acceleration CRAFTER_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Longitudinal acceleration CRAFTER_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Longitudinal acceleration, raw CRAFTER_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Specified idle RPM CRAFTER_MQB_DQ250_SPECIFIED_IDLE_RPM

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2006 to 2026.

Speed ​​output CRAFTER_MQB_DQ250_SPD_OUTPUT

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2006 to 2026.

Transmission input shaft speed CRAFTER_PQ35_TRANS_IN_SPD

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2006 to 2026.

Transmission input speed CRAFTER_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2006 to 2026.

Transmission output speed CRAFTER_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Vehicle lateral acceleration, raw value CRAFTER_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2006 to 2026.

Vehicle speed CRAFTER_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x4B = 75 → 75 km/h

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Vehicle speed from transmission CRAFTER_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 400 km/h
Unit
km/h

In testing for 2006 to 2026.

Yaw acceleration, raw value CRAFTER_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2006 to 2026.

Transmission

Actual position of gear positioner a CRAFTER_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Actual position of gear positioner b CRAFTER_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Actual position of gear positioner c CRAFTER_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Actual position of gear positioner d CRAFTER_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Automatic transmission input speed CRAFTER_AT_INPUT_SPEED

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2026.

Automatic transmission output speed CRAFTER_AT_OUTPUT_SPEED

  • Service 22DID 2103
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2026.

Clutch 1 actual pressure CRAFTER_PQ35_CLUTCH_1_ACTUAL_P

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 actual pressure raw value CRAFTER_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 0 position CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 1 moment CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 1 position CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 2 moment CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 2 position CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 3 moment CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 1 adaptation basic characteristic point 3 position CRAFTER_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 characteristic curve shift CRAFTER_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

In testing for 2006 to 2026.

Clutch 1 commanded pressure CRAFTER_PQ35_CLUTCH_1_CMD_P

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 1 failed adaptations counter CRAFTER_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 1 friction value correction factor CRAFTER_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Clutch 1 protection function engaged quantity CRAFTER_PQ35_CLUTCH_1_PROT_ENGAGED_QTY

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2006 to 2026.

Clutch 1 successful adaptations counter CRAFTER_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 1 valve current: actual CRAFTER_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2006 to 2026.

Clutch 1 valve current: specified CRAFTER_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2006 to 2026.

Clutch 2 actual pressure CRAFTER_PQ35_CLUTCH_2_ACTUAL_P

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 actual torque CRAFTER_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 0 moment CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 0 position CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 1 moment CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 1 position CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 2 moment CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 2 position CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 3 moment CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Clutch 2 adaptation basic characteristic point 3 position CRAFTER_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 adaptation end position closed CRAFTER_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 adaptation end position opened CRAFTER_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 characteristic curve shift CRAFTER_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

In testing for 2006 to 2026.

Clutch 2 commanded pressure CRAFTER_PQ35_CLUTCH_2_CMD_P

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Clutch 2 failed adaptations counter CRAFTER_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 2 friction value correction factor CRAFTER_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Clutch 2 protection function engaged quantity CRAFTER_PQ35_CLUTCH_2_PROT_ENGAGED_QTY

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2006 to 2026.

Clutch 2 successful adaptations counter CRAFTER_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Clutch 2 valve current: actual CRAFTER_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2006 to 2026.

Clutch 2 valve current: specified CRAFTER_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2006 to 2026.

Clutch adaptation values initial kill point 0 for K1 CRAFTER_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Clutch adaptation values initial kill point 0 for K2 CRAFTER_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Clutch adaptation values lower current point adaptation K1 CRAFTER_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Clutch adaptation values lower current point adaptation K2 CRAFTER_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Clutch engagement point rapid adaptation remaining CRAFTER_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2026.

Correction values for main press adaptation: high press on clutch 1 CRAFTER_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Correction values for main press adaptation: low press on clutch 1 CRAFTER_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 CRAFTER_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 CRAFTER_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2006 to 2026.

Current gear CRAFTER_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x08 = 8 → 8

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Current gear CRAFTER_MQB_TCM_I_GEAR_DQ200

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2006 to 2026.

Current gear CRAFTER_PQ35_GEAR

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2006 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation CRAFTER_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation CRAFTER_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation CRAFTER_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation CRAFTER_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2006 to 2026.

Driving strategy mountain factor CRAFTER_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Driving strategy sport factor CRAFTER_PQ35_DRIVING_STRATEGY_SPORT_FACTOR

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Engaged position side a gear selector 1-3 CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side a gear selector 2-4 CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side a gear selector 5 and neutral CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side a gear selector 6 and reverse CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side b gear selector 1-3 CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side b gear selector 2-4 CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side b gear selector 5 and neutral CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engaged position side b gear selector 6 and reverse CRAFTER_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Engine specified torque during transmission intervention CRAFTER_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006 to 2026.

Gear CRAFTER_GEAR_V2

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G1 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G2 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G3 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G4 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G5 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G6 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position G7 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation engaged position GR CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G1 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G2 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G3 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G4 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G5 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G6 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position G7 CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear actuator adaptation synchronization position reverse CRAFTER_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear selector a adaptation neutral position CRAFTER_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear selector b adaptation neutral position CRAFTER_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear selector c adaptation neutral position CRAFTER_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear selector d adaptation neutral position CRAFTER_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2006 to 2026.

Gear selector synchronous position G1 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position G2 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position G3 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position G4 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position G5 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position G6 CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Gear selector synchronous position, reverse CRAFTER_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2006 to 2026.

Input shaft 1 CRAFTER_MQB_INPUT_SHAFT_1

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Input shaft 2 CRAFTER_MQB_INPUT_SHAFT_2

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation CRAFTER_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2006 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation CRAFTER_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2006 to 2026.

Neutral position gear selector 1-3 CRAFTER_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Neutral position gear selector 2-4 CRAFTER_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Neutral position gear selector 5 and neutral CRAFTER_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Neutral position gear selector 6 and reverse CRAFTER_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Output shaft 1 CRAFTER_MQB_OUTPUT_SHAFT_1

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Output shaft 2 CRAFTER_MQB_OUTPUT_SHAFT_2

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2026.

Powertrain overall gear ratio CRAFTER_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2006 to 2026.

Road resistance CRAFTER_PQ35_ROAD_RESISTANCE

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

In testing for 2006 to 2026.

Selected gear CRAFTER_PQ35_SELECTED_GEAR

  • Service 22DID 15AA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Selected gear CRAFTER_SELECTED_GEAR

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2006 to 2026.

Specified torque clutch 1 CRAFTER_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Specified torque clutch 2 CRAFTER_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

In testing for 2006 to 2026.

Synchronous position side a gear selector 1-3 CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side a gear selector 2-4 CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side a gear selector 5 and neutral CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side a gear selector 6 and reverse CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side b gear selector 1-3 CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side b gear selector 2-4 CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side b gear selector 5 and neutral CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Synchronous position side b gear selector 6 and reverse CRAFTER_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2006 to 2026.

Torque converter lockup clutch status CRAFTER_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS

  • Service 22DID 7078
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2026.

Torque loss adaptation, A/C compressor + gear engaged CRAFTER_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Torque loss adaptation, gear engaged CRAFTER_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2006 to 2026.

Transmission gear ratio CRAFTER_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2006 to 2026.

Transmission part 1 pressure actual CRAFTER_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2006 to 2026.

Transmission part 1 pressure commanded CRAFTER_MQB_TCM_TRANSMISSION_PART_1_P_CMD

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2006 to 2026.

Transmission part 1 valve current actual CRAFTER_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2006 to 2026.

Transmission part 1 valve current commanded CRAFTER_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2006 to 2026.

Transmission part 2 pressure actual CRAFTER_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2006 to 2026.

Transmission part 2 pressure commanded CRAFTER_MQB_TCM_TRANSMISSION_PART_2_P_CMD

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2006 to 2026.

Transmission part 2 valve current actual CRAFTER_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2006 to 2026.

Transmission part 2 valve current commanded CRAFTER_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2006 to 2026.

Upper adapted coupling point clutch 1 from slip adaptation CRAFTER_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2006 to 2026.

Upper adapted coupling point clutch 2 from slip adaptation CRAFTER_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2006 to 2026.

Working hours CRAFTER_PQ35_WORKING_HOURS

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

In testing for 2006 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 CRAFTER_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 1 temperature time in range 2 CRAFTER_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 1 temperature time in range 3 CRAFTER_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 2 temperature time in range 0 CRAFTER_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 2 temperature time in range 1 CRAFTER_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 2 temperature time in range 2 CRAFTER_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Analysis, clutch 2 temperature time in range 3 CRAFTER_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Clutch 1 adaptation kiss point part 1 odometer reading CRAFTER_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2006 to 2026.

Clutch 1 temperature time in range 0 CRAFTER_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2006 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading CRAFTER_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2006 to 2026.

Distance to empty CRAFTER_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2023, 2025 to 2026. Not supported for 2024.

Drive cycles counter CRAFTER_MQB_TCM_DRIVE_CYCLES_COUNTER

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Driving time ecological CRAFTER_MQB_TCM_DRIVING_TIME_ECOLOGICAL

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Driving time manual CRAFTER_MQB_TCM_DRIVING_TIME_MANUAL

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Driving time sporty CRAFTER_MQB_TCM_DRIVING_TIME_SPORTY

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2026.

Ignition cycles CRAFTER_MQB_TCM_IGNITION_CYCLES

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2026.

Odometer CRAFTER_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0
  • Every30 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x00874F = 34639 → 34,639 km

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Odometer CRAFTER_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4000000000 km
Unit
km

In testing for 2006 to 2023, 2025 to 2026. Not supported for 2024.

Odometer CRAFTER_ODO_V1Confirmed

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x00054916 = 346390 → 34639010 = 34,639 km

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Odometer #2 CRAFTER_MQB_TCM_ODO_2Confirmed

  • Service 22DID 3887
  • Module7E1
  • Every30 s
  • Testing for 2006 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Crafter.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x00000000 = 0 → 010 = 0 km

Confirmed for 2024. In testing for 2006 to 2023, 2025 to 2026.

Odometer, alternate CRAFTER_PQ35_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2006 to 2026.

Odometer, mileage, HR CRAFTER_ODO_MILEAGE_HR

Pelican can show this parameter as the odometer.

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2006 to 2026.

Operating time, temperature range 1 CRAFTER_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Operating time, temperature range 2 CRAFTER_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Operating time, temperature range 3 CRAFTER_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Operating time, temperature range 4 CRAFTER_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Operating time, temperature range 5 CRAFTER_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Operating time, temperature range 6 CRAFTER_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2006 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.