Acura ILX

Parameters

The Acura ILX has 321 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery coolant temperature ILX_BATTERY_COOLANT_TEMPERATURE

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery coolant temperature ILX_BATTERY_COOLANT_TEMPERATURE

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Battery module power ILX_BATTERY_MODULE_POWER

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val×0.016
Range
-524.288 to 524.272 kW
Unit
kW

In testing for 2013 to 2022.

Cell voltage limit during charge ILX_CEL_V_LIM

  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Charging voltage target ILX_CHG_V_TGT

  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2016. Supported for 2013, 2015.

Distance traveled since last charge ILX_BAT_DIST

  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

In testing for 2013 to 2022.

High voltage battery cells, max state of charge ILX_CELL_MAX_SOC

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

High voltage battery cells, max state of charge ILX_CELL_MIN_SOC

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

High voltage battery module 1A temperature ILX_HVB_MOD_1A_T

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery module 1B temperature ILX_HVB_MOD_1B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery module 2A temperature ILX_HVB_MOD_2A_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 488 to 503 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery module 3A temperature ILX_HVB_MOD_3A_T

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery module 3B temperature ILX_HVB_MOD_3B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery module 4B temperature ILX_HVB_MOD_4B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 520 to 535 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

High voltage battery total capacity ILX_HVB_CAP

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2013 to 2022.

High voltage battery total current ILX_HVB_C_TOTAL

Pelican can show this parameter as the traction battery current.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-100 to 200 A
Unit
A

In testing for 2013 to 2022.

High voltage battery voltage ILX_HVB_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

In testing for 2013 to 2022.

High voltage battery voltage, line b ILX_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

In testing for 2013 to 2022.

HV battery cell max state of charge ILX_HV_BATTERY_CELL_MAX_STATE_OF_CHARGE

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2013 to 2022.

HV battery current ILX_HV_BATTERY_CURRENT

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2013 to 2022.

HV battery fan 3 speed ILX_HV_BATTERY_FAN_3_SPEED

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2013 to 2022.

HV battery max cell voltage ILX_HV_BATTERY_MAX_CELL_VOLTAGE

  • Service 22DID 2222
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2022.

HV battery usable capacity ILX_HV_BATTERY_USABLE_CAPACITY

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

Normal charger input voltage ILX_CHG_V_IN

  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val10
Range
0 to 500 V
Unit
V

In testing for 2013 to 2022.

Normal charger output voltage ILX_CHG_V_OUT

  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val10
Range
0 to 500 V
Unit
V

In testing for 2013 to 2022.

State of charge ILX_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

State of charge ILX_STATE_OF_CHARGE

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

Cells

Battery capacity, line b ILX_HVB_CAP_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2013 to 2022.

Cell voltage, 1 ILX_CEL_V_B1

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 2 ILX_CEL_V_B2

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 3 ILX_CEL_V_B3

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 4 ILX_CEL_V_B4

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 5 ILX_CEL_V_B5

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 6 ILX_CEL_V_B6

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 7 ILX_CEL_V_B7

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 8 ILX_CEL_V_B8

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 9 ILX_CEL_V_B9

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 10 ILX_CEL_V_B10

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 11 ILX_CEL_V_B11

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 12 ILX_CEL_V_B12

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 13 ILX_CEL_V_B13

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 14 ILX_CEL_V_B14

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 15 ILX_CEL_V_B15

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 16 ILX_CEL_V_B16

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 17 ILX_CEL_V_B17

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 18 ILX_CEL_V_B18

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 19 ILX_CEL_V_B19

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 20 ILX_CEL_V_B20

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 21 ILX_CEL_V_B21

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 22 ILX_CEL_V_B22

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 23 ILX_CEL_V_B23

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 24 ILX_CEL_V_B24

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 25 ILX_CEL_V_B25

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 26 ILX_CEL_V_B26

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 27 ILX_CEL_V_B27

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 28 ILX_CEL_V_B28

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 29 ILX_CEL_V_B29

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 30 ILX_CEL_V_B30

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 31 ILX_CEL_V_B31

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 32 ILX_CEL_V_B32

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 33 ILX_CEL_V_B33

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 34 ILX_CEL_V_B34

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 35 ILX_CEL_V_B35

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 36 ILX_CEL_V_B36

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 37 ILX_CEL_V_B37

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 38 ILX_CEL_V_B38

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 39 ILX_CEL_V_B39

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 40 ILX_CEL_V_B40

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 41 ILX_CEL_V_B41

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 42 ILX_CEL_V_B42

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 43 ILX_CEL_V_B43

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 44 ILX_CEL_V_B44

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 45 ILX_CEL_V_B45

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 46 ILX_CEL_V_B46

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 47 ILX_CEL_V_B47

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 48 ILX_CEL_V_B48

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 49 ILX_CEL_V_B49

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 50 ILX_CEL_V_B50

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 51 ILX_CEL_V_B51

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 52 ILX_CEL_V_B52

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 53 ILX_CEL_V_B53

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 54 ILX_CEL_V_B54

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 55 ILX_CEL_V_B55

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 56 ILX_CEL_V_B56

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 57 ILX_CEL_V_B57

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 58 ILX_CEL_V_B58

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 59 ILX_CEL_V_B59

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 60 ILX_CEL_V_B60

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 61 ILX_CEL_V_B61

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 62 ILX_CEL_V_B62

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 63 ILX_CEL_V_B63

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 64 ILX_CEL_V_B64

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 65 ILX_CEL_V_B65

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 66 ILX_CEL_V_B66

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 67 ILX_CEL_V_B67

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 68 ILX_CEL_V_B68

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 69 ILX_CEL_V_B69

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 70 ILX_CEL_V_B70

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 71 ILX_CEL_V_B71

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 72 ILX_CEL_V_B72

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 73 ILX_CEL_V_B73

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 74 ILX_CEL_V_B74

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 75 ILX_CEL_V_B75

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 76 ILX_CEL_V_B76

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 77 ILX_CEL_V_B77

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 78 ILX_CEL_V_B78

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 79 ILX_CEL_V_B79

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 80 ILX_CEL_V_B80

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 81 ILX_CEL_V_B81

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 82 ILX_CEL_V_B82

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 83 ILX_CEL_V_B83

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Cell voltage, 84 ILX_CEL_V_B84

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell max SOC, line b ILX_CEL_MAX_SOC_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

Individual cell min SOC, line b ILX_CEL_MIN_SOC_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

Individual cell voltage A1 ILX_CEL_V_A1

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A2 ILX_CEL_V_A2

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A3 ILX_CEL_V_A3

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A4 ILX_CEL_V_A4

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A5 ILX_CEL_V_A5

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A6 ILX_CEL_V_A6

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A7 ILX_CEL_V_A7

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A8 ILX_CEL_V_A8

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A9 ILX_CEL_V_A9

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A10 ILX_CEL_V_A10

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A11 ILX_CEL_V_A11

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A12 ILX_CEL_V_A12

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A13 ILX_CEL_V_A13

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A14 ILX_CEL_V_A14

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A15 ILX_CEL_V_A15

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A16 ILX_CEL_V_A16

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A17 ILX_CEL_V_A17

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A18 ILX_CEL_V_A18

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A19 ILX_CEL_V_A19

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A20 ILX_CEL_V_A20

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A21 ILX_CEL_V_A21

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A22 ILX_CEL_V_A22

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A23 ILX_CEL_V_A23

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A24 ILX_CEL_V_A24

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A25 ILX_CEL_V_A25

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A26 ILX_CEL_V_A26

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A27 ILX_CEL_V_A27

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A28 ILX_CEL_V_A28

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A29 ILX_CEL_V_A29

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A30 ILX_CEL_V_A30

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A31 ILX_CEL_V_A31

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A32 ILX_CEL_V_A32

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A33 ILX_CEL_V_A33

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A34 ILX_CEL_V_A34

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A35 ILX_CEL_V_A35

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A36 ILX_CEL_V_A36

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A37 ILX_CEL_V_A37

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A38 ILX_CEL_V_A38

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A39 ILX_CEL_V_A39

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A40 ILX_CEL_V_A40

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A41 ILX_CEL_V_A41

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A42 ILX_CEL_V_A42

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A43 ILX_CEL_V_A43

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A44 ILX_CEL_V_A44

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A45 ILX_CEL_V_A45

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A46 ILX_CEL_V_A46

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A47 ILX_CEL_V_A47

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A48 ILX_CEL_V_A48

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A49 ILX_CEL_V_A49

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A50 ILX_CEL_V_A50

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A51 ILX_CEL_V_A51

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A52 ILX_CEL_V_A52

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A53 ILX_CEL_V_A53

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A54 ILX_CEL_V_A54

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A55 ILX_CEL_V_A55

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A56 ILX_CEL_V_A56

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A57 ILX_CEL_V_A57

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A58 ILX_CEL_V_A58

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A59 ILX_CEL_V_A59

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A60 ILX_CEL_V_A60

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A61 ILX_CEL_V_A61

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A62 ILX_CEL_V_A62

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A63 ILX_CEL_V_A63

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A64 ILX_CEL_V_A64

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A65 ILX_CEL_V_A65

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A66 ILX_CEL_V_A66

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A67 ILX_CEL_V_A67

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A68 ILX_CEL_V_A68

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A69 ILX_CEL_V_A69

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A70 ILX_CEL_V_A70

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A71 ILX_CEL_V_A71

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A72 ILX_CEL_V_A72

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A73 ILX_CEL_V_A73

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A74 ILX_CEL_V_A74

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A75 ILX_CEL_V_A75

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A76 ILX_CEL_V_A76

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A77 ILX_CEL_V_A77

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A78 ILX_CEL_V_A78

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A79 ILX_CEL_V_A79

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A80 ILX_CEL_V_A80

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A81 ILX_CEL_V_A81

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A82 ILX_CEL_V_A82

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A83 ILX_CEL_V_A83

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Individual cell voltage A84 ILX_CEL_V_A84

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2013 to 2022.

Climate

A/C pressure ILX_AC_P

  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 4000 kPa
Unit
kPa

In testing for 2013 to 2022.

Outside air temperature ILX_AATConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 2013 to 2014, 2017 to 2022

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °F
Unit
°F

Confirmed for 2015 to 2016. In testing for 2013 to 2014, 2017 to 2022.

Clocks

Time since engine start ILX_RUNTM_PCM

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2013 to 2022.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016. Supported for 2013, 2015.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016. Supported for 2013, 2015.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2016. Supported for 2013, 2015.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2016. Supported for 2013, 2015.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2016. Supported for 2013, 2015.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2016. Supported for 2013, 2015.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2016. Supported for 2013, 2015.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016. Supported for 2013, 2015.

ECU

Knock control ILX_KNOCK_CTRL_PCM

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 1 ILX_MIS_1_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 2 ILX_MIS_2_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 3 ILX_MIS_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 4 ILX_MIS_4_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 5 ILX_MIS_5_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count, cylinder 6 ILX_MIS_6_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Electrical

Brake fluid pressure ILX_BRK_FLD_P

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

In testing for 2013 to 2022.

Brake pedal stroke ILX_BRK_PED_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

In testing for 2013 to 2022.

Brake pressure ILX_BRK_P

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

In testing for 2013 to 2022.

Brake switch ILX_BRK_SW

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022.

Master cylinder stroke ILX_MSTR_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

In testing for 2013 to 2022.

Slave cylinder stroke ILX_SLV_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

In testing for 2013 to 2022.

Engine

A/C clutch ILX_AC_CLU_PCM

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Active cylinders ILX_ACTIVE_CYL_PCM

  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2013 to 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2016. Supported for 2013, 2015.

Air/gas ratio ILX_AIRGAS_RAT_PCM

  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

In testing for 2013 to 2022.

Ambient air temperature, cabin ILX_AAT_CAB

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2013 to 2022.

Ambient air temperature, outside ILX_AAT_OUT

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2013 to 2022.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2016. Supported for 2013, 2015.

Cabin air temperature ILX_CABIN_AIR_TEMPERATURE

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

In testing for 2013 to 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2016. Supported for 2013, 2015.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016. Supported for 2013, 2015.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

DC-DC converter temperature ILX_DC_DC_CONVERTER_TEMPERATURE

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2013 to 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016. Supported for 2013, 2015.

Engine coolant temperature sensor 1 ILX_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine coolant temperature sensor 2 ILX_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine coolant temperature sensor 3 ILX_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine coolant temperature sensor 4 ILX_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine oil temperature, variant 3 ILX_EOT_VAR_3_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine oil temperature, variant 4 ILX_EOT_VAR_4_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2022.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2016. Supported for 2013, 2015.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2016. Supported for 2013, 2015.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2016.

Fuel/air commanded equivalence ratio ILX_FUELAIR_CAR_PCM

  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

In testing for 2013 to 2022.

Generator ILX_GENERATOR_PCM

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016. Supported for 2013, 2015.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2016. Supported for 2013, 2015.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Maintenance, air cleaner ILX_MAINT_AIR_CLN

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, cabin filter ILX_MAINT_CABIN_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, engine coolant ILX_MAINT_COOL

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, general inspection ILX_MAINT_INSP

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, oil & filter ILX_MAINT_OIL_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, rake fluid ILX_MAINT_BRK_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, spark plugs & valves ILX_MAINT_SPARK

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Maintenance, transmission fluid ILX_MAINT_TRANS_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Misfire count #1, variant 1 ILX_MIS_CNT_1_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #1, variant 3 ILX_MIS_CNT_1_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count #2, variant 1 ILX_MIS_CNT_2_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #2, variant 3 ILX_MIS_CNT_2_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count #3, variant 1 ILX_MIS_CNT_3_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #3, variant 3 ILX_MIS_CNT_3_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count #4, variant 1 ILX_MIS_CNT_4_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #4, variant 3 ILX_MIS_CNT_4_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count #5, variant 1 ILX_MIS_CNT_5_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #5, variant 3 ILX_MIS_CNT_5_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Misfire count #6, variant 1 ILX_MIS_CNT_6_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Misfire count #6, variant 3 ILX_MIS_CNT_6_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2022.

Motor inverter, current ILX_MOTOR_INVERTER_CURRENT

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2013 to 2022.

Outside air temperature ILX_OUTSIDE_AIR_TEMPERATURE

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

In testing for 2013 to 2022.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2016. Supported for 2013, 2015.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2016. Supported for 2013, 2015.

Variable valve timing duty ILX_VTC_DUTY_PCM

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2022.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016. Supported for 2015.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2016. Supported for 2015.

Fuel

Air-fuel mixture heater ILX_AIR_FUEL_MIXTURE

  • Service 22DID 266D
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2013 to 2022.

Fuel level ILX_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2013 to 2014, 2017 to 2022

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

Confirmed for 2015 to 2016. In testing for 2013 to 2014, 2017 to 2022.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2013, 2015.

Movement

Generator motor speed ILX_GENERATOR_MOTOR_SPEED

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×64
Range
0 to 16320 rpm
Unit
rpm

In testing for 2013 to 2022.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2016. Supported for 2013, 2015.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2016. Supported for 2013, 2015.

Tires

Front left tire pressure ILX_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Front left tire temperature ILX_TT_FLConfirmed

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 200 to 207 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Front right tire pressure ILX_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Front right tire temperature ILX_TT_FRConfirmed

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Maintenance, tire rotation ILX_MAINT_TIRE

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2022.

Rear left tire pressure ILX_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Rear left tire temperature ILX_TT_RLConfirmed

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Rear right tire pressure ILX_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Rear right tire temperature ILX_TT_RRConfirmed

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.

Transmission

Current gear var.2 ILX_CURRENT_GEAR_VAR_2

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Current gear var.3 ILX_CURRENT_GEAR_VAR_3

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2022.

Trips

Odometer ILX_ODO_PCM

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2022.

Odometer, variation 3 ILX_ODO_V3

  • Service 22DID 7022
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 200000 mi
Unit
mi

In testing for 2013 to 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.