Acura Integra

Parameters

The Acura Integra has 207 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage VPWRConfirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023 to 2025. Supported for 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023 to 2025. Supported for 2026.

Climate

A/C clutch INTEGRA_AC_CLUTCHConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2026.

Outside air temperature INTEGRA_AATConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 1996 to 2006

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °F
Unit
°F

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Clocks

Time since engine start INTEGRA_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023 to 2026.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023, 2025. Supported for 2024, 2026.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023, 2025. Supported for 2024, 2026.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2023, 2025. Supported for 2024, 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023, 2025. Supported for 2024, 2026.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023, 2025. Supported for 2024, 2026.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023, 2025. Supported for 2024, 2026.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023, 2025. Supported for 2024, 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024, 2026.

ECU

Variable valve control INTEGRA_VTEC_CTRLConfirmed

  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1996 to 2006

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Electrical

Brake fluid pressure INTEGRA_BRK_FLD_P

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

In testing for 1996 to 2006, 2025. Not supported for 2023 to 2024, 2026.

Brake pedal stroke INTEGRA_BRK_PED_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

In testing for 1996 to 2006, 2025. Not supported for 2023 to 2024, 2026.

Brake pressure INTEGRA_BRK_PConfirmed

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every250 ms
  • Testing for 1996 to 2006

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Brake switch INTEGRA_BRK_SWConfirmed

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every250 ms
  • Testing for 1996 to 2006

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Master cylinder stroke INTEGRA_MSTR_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

In testing for 1996 to 2006, 2025. Not supported for 2023 to 2024, 2026.

Slave cylinder stroke INTEGRA_SLV_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

In testing for 1996 to 2006, 2025. Not supported for 2023 to 2024, 2026.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

Active cylinders INTEGRA_ACTIVE_CYLConfirmed

  • Service 22DID 2615
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2006

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024 to 2026.

Air/gas ratio INTEGRA_AIRGAS_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1996 to 2006

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2025. Supported for 2023.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2025. Supported for 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2025. Supported for 2023.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2025. Supported for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023 to 2026.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024.

Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2025 to 2026.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Engine oil temperature, variant 3 INTEGRA_EOT_VAR_3Confirmed

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006, 2023, 2025 to 2026

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 1996 to 2006, 2025. Not supported for 2023, 2026.

Engine oil temperature, variant 4 INTEGRA_EOT_VAR_4Confirmed

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006, 2023, 2025 to 2026

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 1996 to 2006, 2025. Not supported for 2023, 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023 to 2025. Supported for 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Fuel/air commanded equivalence ratio INTEGRA_FUELAIR_CARConfirmed

  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1996 to 2006

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Generator INTEGRA_GENERATORConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Knock control INTEGRA_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1996 to 2006

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Raw value

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Maintenance, air cleaner INTEGRA_MAINT_AIR_CLN

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, brake fluid INTEGRA_MAINT_BRK_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, cabin filter INTEGRA_MAINT_CABIN_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, engine coolant INTEGRA_MAINT_COOL

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, general inspection INTEGRA_MAINT_INSP

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, oil & filter INTEGRA_MAINT_OIL_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, spark plugs & valves INTEGRA_MAINT_SPARK

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Maintenance, transmission fluid INTEGRA_MAINT_TRANS_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2023.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2023.

Misfire count, cylinder 1 INTEGRA_MIS_1Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2006

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Misfire count, cylinder 2 INTEGRA_MIS_2Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2006

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Misfire count, cylinder 3 INTEGRA_MIS_3Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2006

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Misfire count, cylinder 4 INTEGRA_MIS_4Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2006

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Relative Throttle A Position TP_A_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024.

Relative Throttle B Position TP_B_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023 to 2026.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Variable valve timing duty INTEGRA_VTC_DUTYConfirmed

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1996 to 2006

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025.

Internal

Boost bressure A control status BP_ASAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2025. Supported for 2023.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023.

Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024 to 2025. Supported for 2023, 2026.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. Supported for 2023 to 2024.

Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

Confirmed for 2025. Supported for 2023 to 2024.

Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2025. Supported for 2023 to 2024.

Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2025. Supported for 2023 to 2024.

Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023, 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2024 to 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023 to 2025.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2024 to 2025. Supported for 2023, 2026.

SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2025. Supported for 2023 to 2024, 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2024 to 2026.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2023 to 2025.

Fuel

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024 to 2026. Supported for 2023.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024 to 2026. Supported for 2023.

Fuel level INTEGRA_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 1996 to 2006

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2024 to 2026. Supported for 2023.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2024 to 2026. Supported for 2023.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024 to 2026. Supported for 2023.

Internal

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2023 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2023 to 2025. Supported for 2026.

Tires

Front left tire pressure INTEGRA_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Front left tire temperature INTEGRA_TT_FLConfirmed

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 200 to 207 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Front right tire pressure INTEGRA_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Front right tire temperature INTEGRA_TT_FRConfirmed

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Maintenance, tire rotation INTEGRA_MAINT_TIRE

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1996 to 2006. Not supported for 2023 to 2026.

Rear left tire pressure INTEGRA_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Rear left tire temperature INTEGRA_TT_RLConfirmed

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Rear right tire pressure INTEGRA_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Rear right tire temperature INTEGRA_TT_RRConfirmed

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing for 1996 to 2006

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Trips

Odometer INTEGRA_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2006

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024 to 2025. Supported for 2023.

Odometer, variation 3 INTEGRA_ODO_V3Confirmed

  • Service 22DID 7022
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 1996 to 2006

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 200000 mi
Unit
mi

Confirmed for 2023 to 2026. In testing for 1996 to 2006.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.