Audi A3 e-tron

Parameters

The Audi A3 e-tron has 1,313 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage A3E_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x287D = 10365 → 103651000+4 = 14.365 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery capacity A3E_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

AC charging A3E_AC_CHARGINGConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Accelerator pedal, sensor 1 voltage A3E_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal, sensor 2 voltage A3E_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Aux. hydraulic pump voltage A3E_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Battery acid stratification A3E_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Battery cell soc max, ID A3E_HVBAT_CELL_SOC_MAX_ID

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

Battery cell soc min, ID A3E_HVBAT_CELL_SOC_MIN_ID

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

Battery cell soc, maximum A3E_HVBAT_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery cell soc, minimum A3E_HVBAT_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery charge level A3E_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x42 = 66 → 66 %

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery condition for display A3E_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Battery current A3E_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483 A
Unit
A

0x00000C1E = 3102 → 31021000 = 3.102 A

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery current filtered A3E_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Battery current limit, charging A3E_HVBAT_I_LIM_CHGConfirmed

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery current limit, discharging A3E_HVBAT_I_LIM_DSCHConfirmed

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery energy content A3E_BAT_ENERGY_CONTENTConfirmed

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

0x01360000 = 20316160 → 203161601310770 = 15.499409 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery internal resistance A3E_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x19 = 25 → 25×20100 = 5

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery internal resistance, raw A3E_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Battery power reduction active A3E_BMS_PWR_REDUCE_ACTConfirmed

  • Service 22DID 1E0A
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery sensor temperature A3E_MQB_BAT_SEN_TConfirmed

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery temperature A3E_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery temperature, inlet A3E_HVBAT_T_IN

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

Battery temperature, max A3E_HVBAT_T_MAX_V2Confirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery temperature, max sensor ID A3E_HVBAT_T_MAX_ID

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

Battery temperature, min A3E_HVBAT_T_MINConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery temperature, min sensor ID A3E_HVBAT_T_MIN_ID

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

Battery temperature, outlet A3E_HVBAT_T_OUTConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery total charge A3E_MQB_BAT_TOT_CHGConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00012519 = 75033 → 7503310 = 7,503.3 Ah

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery total discharge A3E_MQB_BAT_TOT_DISConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x0001168A = 71306 → 7130610 = 7,130.6 Ah

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery voltage A3E_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x287D = 10365 → 103651000+4 = 14.365 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery voltage A3E_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Battery voltage at rest A3E_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x21 = 33 → 3310+9 = 12.3 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Battery voltage, after main switch A3E_HVBAT_V_AFTERConfirmed

  • Service 22DID 1E38
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Battery voltage, sum of all cells A3E_HVBAT_V_CELLS_SUM

  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×2441406251000000000
Range
-524288 to 524287.99 V
Unit
V

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Bypass valve high pressure turbine inlet, raw voltage A3E_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Cell state of charge max, index A3E_BMS_CELL_SOC_MAX_IDXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell state of charge max, value A3E_BMS_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x0F = 15 → 15 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell state of charge min, index A3E_BMS_CELL_SOC_MIN_IDXConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell state of charge min, value A3E_BMS_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x0F = 15 → 15 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell voltage max, index A3E_BMS_CELL_V_MAX_IDXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell voltage max, value A3E_BMS_CELL_V_MAXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0BF4 = 3060 → 30601000 = 3.06 V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell voltage min, index A3E_BMS_CELL_V_MIN_IDXConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cell voltage min, value A3E_BMS_CELL_V_MINConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0B43 = 2883 → 28831000 = 2.883 V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Charge adjuster output stage A3E_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value A3E_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Charge air pressure A3E_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Charge air pressure actuator position digit.value A3E_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Charge air pressure actuator, acknowledgment A3E_CHG_AIR_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Charge air pressure, actual value A3E_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Charge air pressure, actual value A3E_CHG_AIR_P_ACT

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Charge air pressure, specified value A3E_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, actual position A3E_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, adaptation for lower stop A3E_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, adaptation for upper stop A3E_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, maximum sensor voltage A3E_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, specified position A3E_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure actuator, specified value A3E_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure before throttle valve, calculated actual value A3E_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control adaptation higher than max. threshold A3E_CHG_P_CTRL_ADPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control adaptation lower than min. threshold A3E_CHG_P_CTRL_ADPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control specified value A3E_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve activation pulse duty factor A3E_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve position, actual value A3E_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve position, target value A3E_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve sensor voltage A3E_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve voltage, position closed A3E_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure control valve voltage, position opened A3E_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure regulator, lower threshold adaptation A3E_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure regulator, upper threshold adaptation A3E_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Charge pressure sensor, unconditioned voltage A3E_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Charger coolant temperature A3E_CHRGR_COOLANT_TConfirmed

  • Service 22DID 15E2
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x18 = 24 → 24−40 = -16 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Charger output current A3E_CHG_HV_I

  • Service 22DID 4237
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Charger output current set point A3E_CHG_HV_I_SET

  • Service 22DID 4238
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Charging, rapid? A3E_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Control module voltage A3E_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x3804 = 14340 → 143401000 = 14.34 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2017. Supported for 2018.

Current gear A3E_DRIVE_MODEConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Cylinder charge specified value A3E_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Cylinder charge, actual value A3E_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

DC battery voltage A3E_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

DC to DC converter high-voltage side voltage A3E_DCDC_HV_V

  • Service 22DID 1587
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

DC-DC converter, current A3E_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

DC-DC converter, low voltage A3E_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x72 = 114 → 11410 = 11.4 V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

DC-DC converter, reserved current A3E_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Electric machine high-voltage battery energy information A3E_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2014 to 2018, 2020 to 2026.

Estimated reserve range A3E_RANGE_EST_CANConfirmed

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Exhaust gas recirculation valve 1, B1, mass current: specified value A3E_MQB_EGR_VALVE_1_B1_MASS_I_SPECConfirmed

  • Service 22DID 1813
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Exhaust gas recirculation valve 2, B1, mass current: specified value A3E_MQB_EGR_VALVE_2_B1_MASS_I_SPECConfirmed

  • Service 22DID 1814
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Generator target voltage A3E_MQB_GEN_TRG_VConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
10.6 to 36.1 V
Unit
V

0x26 = 38 → 3810+10.6 = 14.4 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Generator voltage, actual A3E_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

High pressure exhaust gas recirculation actuator, actual unconditioned voltage A3E_HIGH_P_EGR_ACTUATOR_ACT_V

  • Service 22DID 11A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

High voltage battery energy information A3E_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2014 to 2018, 2020 to 2026.

High voltage output A3E_OBC_HIGH_V_OUTPUTConfirmed

  • Service 22DID 1DA7
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery after contacts voltage A3E_HVBAT_AFTER_CONTACTS_V

  • Service 22DID 189B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 V
Unit
V

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

HV battery cell 1 voltage A3E_HVBAT_CELL_1_V

  • Service 22DID 1E40
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 2 voltage A3E_HVBAT_CELL_2_V

  • Service 22DID 1E41
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 3 voltage A3E_HVBAT_CELL_3_V

  • Service 22DID 1E42
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 4 voltage A3E_HVBAT_CELL_4_V

  • Service 22DID 1E43
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 5 voltage A3E_HVBAT_CELL_5_V

  • Service 22DID 1E44
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 6 voltage A3E_HVBAT_CELL_6_V

  • Service 22DID 1E45
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 7 voltage A3E_HVBAT_CELL_7_V

  • Service 22DID 1E46
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 8 voltage A3E_HVBAT_CELL_8_V

  • Service 22DID 1E47
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 9 voltage A3E_HVBAT_CELL_9_V

  • Service 22DID 1E48
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 10 voltage A3E_HVBAT_CELL_10_V

  • Service 22DID 1E49
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 11 voltage A3E_HVBAT_CELL_11_V

  • Service 22DID 1E4A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 12 voltage A3E_HVBAT_CELL_12_V

  • Service 22DID 1E4B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 13 voltage A3E_HVBAT_CELL_13_V

  • Service 22DID 1E4C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 14 voltage A3E_HVBAT_CELL_14_V

  • Service 22DID 1E4D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 15 voltage A3E_HVBAT_CELL_15_V

  • Service 22DID 1E4E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 16 voltage A3E_HVBAT_CELL_16_V

  • Service 22DID 1E4F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 17 voltage A3E_HVBAT_CELL_17_V

  • Service 22DID 1E50
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 18 voltage A3E_HVBAT_CELL_18_V

  • Service 22DID 1E51
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 19 voltage A3E_HVBAT_CELL_19_V

  • Service 22DID 1E52
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 20 voltage A3E_HVBAT_CELL_20_V

  • Service 22DID 1E53
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 21 voltage A3E_HVBAT_CELL_21_V

  • Service 22DID 1E54
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 22 voltage A3E_HVBAT_CELL_22_V

  • Service 22DID 1E55
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 23 voltage A3E_HVBAT_CELL_23_V

  • Service 22DID 1E56
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 24 voltage A3E_HVBAT_CELL_24_V

  • Service 22DID 1E57
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 25 voltage A3E_HVBAT_CELL_25_V

  • Service 22DID 1E58
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 26 voltage A3E_HVBAT_CELL_26_V

  • Service 22DID 1E59
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 27 voltage A3E_HVBAT_CELL_27_V

  • Service 22DID 1E5A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 28 voltage A3E_HVBAT_CELL_28_V

  • Service 22DID 1E5B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 29 voltage A3E_HVBAT_CELL_29_V

  • Service 22DID 1E5C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 30 voltage A3E_HVBAT_CELL_30_V

  • Service 22DID 1E5D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 31 voltage A3E_HVBAT_CELL_31_V

  • Service 22DID 1E5E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 32 voltage A3E_HVBAT_CELL_32_V

  • Service 22DID 1E5F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 33 voltage A3E_HVBAT_CELL_33_V

  • Service 22DID 1E60
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 34 voltage A3E_HVBAT_CELL_34_V

  • Service 22DID 1E61
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 35 voltage A3E_HVBAT_CELL_35_V

  • Service 22DID 1E62
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 36 voltage A3E_HVBAT_CELL_36_V

  • Service 22DID 1E63
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 37 voltage A3E_HVBAT_CELL_37_V

  • Service 22DID 1E64
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 38 voltage A3E_HVBAT_CELL_38_V

  • Service 22DID 1E65
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 39 voltage A3E_HVBAT_CELL_39_V

  • Service 22DID 1E66
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 40 voltage A3E_HVBAT_CELL_40_V

  • Service 22DID 1E67
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 41 voltage A3E_HVBAT_CELL_41_V

  • Service 22DID 1E68
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 42 voltage A3E_HVBAT_CELL_42_V

  • Service 22DID 1E69
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 43 voltage A3E_HVBAT_CELL_43_V

  • Service 22DID 1E6A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 44 voltage A3E_HVBAT_CELL_44_V

  • Service 22DID 1E6B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 45 voltage A3E_HVBAT_CELL_45_V

  • Service 22DID 1E6C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 46 voltage A3E_HVBAT_CELL_46_V

  • Service 22DID 1E6D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 47 voltage A3E_HVBAT_CELL_47_V

  • Service 22DID 1E6E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 48 voltage A3E_HVBAT_CELL_48_V

  • Service 22DID 1E6F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 49 voltage A3E_HVBAT_CELL_49_V

  • Service 22DID 1E70
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 50 voltage A3E_HVBAT_CELL_50_V

  • Service 22DID 1E71
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 51 voltage A3E_HVBAT_CELL_51_V

  • Service 22DID 1E72
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 52 voltage A3E_HVBAT_CELL_52_V

  • Service 22DID 1E73
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 53 voltage A3E_HVBAT_CELL_53_V

  • Service 22DID 1E74
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 54 voltage A3E_HVBAT_CELL_54_V

  • Service 22DID 1E75
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 55 voltage A3E_HVBAT_CELL_55_V

  • Service 22DID 1E76
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 56 voltage A3E_HVBAT_CELL_56_V

  • Service 22DID 1E77
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 57 voltage A3E_HVBAT_CELL_57_V

  • Service 22DID 1E78
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 58 voltage A3E_HVBAT_CELL_58_V

  • Service 22DID 1E79
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 59 voltage A3E_HVBAT_CELL_59_V

  • Service 22DID 1E7A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 60 voltage A3E_HVBAT_CELL_60_V

  • Service 22DID 1E7B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 61 voltage A3E_HVBAT_CELL_61_V

  • Service 22DID 1E7C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 62 voltage A3E_HVBAT_CELL_62_V

  • Service 22DID 1E7D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 63 voltage A3E_HVBAT_CELL_63_V

  • Service 22DID 1E7E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 64 voltage A3E_HVBAT_CELL_64_V

  • Service 22DID 1E7F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 65 voltage A3E_HVBAT_CELL_65_V

  • Service 22DID 1E80
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 66 voltage A3E_HVBAT_CELL_66_V

  • Service 22DID 1E81
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 67 voltage A3E_HVBAT_CELL_67_V

  • Service 22DID 1E82
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 68 voltage A3E_HVBAT_CELL_68_V

  • Service 22DID 1E83
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 69 voltage A3E_HVBAT_CELL_69_V

  • Service 22DID 1E84
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 70 voltage A3E_HVBAT_CELL_70_V

  • Service 22DID 1E85
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 71 voltage A3E_HVBAT_CELL_71_V

  • Service 22DID 1E86
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 72 voltage A3E_HVBAT_CELL_72_V

  • Service 22DID 1E87
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 73 voltage A3E_HVBAT_CELL_73_V

  • Service 22DID 1E88
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 74 voltage A3E_HVBAT_CELL_74_V

  • Service 22DID 1E89
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 75 voltage A3E_HVBAT_CELL_75_V

  • Service 22DID 1E8A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 76 voltage A3E_HVBAT_CELL_76_V

  • Service 22DID 1E8B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 77 voltage A3E_HVBAT_CELL_77_V

  • Service 22DID 1E8C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 78 voltage A3E_HVBAT_CELL_78_V

  • Service 22DID 1E8D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 79 voltage A3E_HVBAT_CELL_79_V

  • Service 22DID 1E8E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 80 voltage A3E_HVBAT_CELL_80_V

  • Service 22DID 1E8F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 81 voltage A3E_HVBAT_CELL_81_V

  • Service 22DID 1E90
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 82 voltage A3E_HVBAT_CELL_82_V

  • Service 22DID 1E91
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 83 voltage A3E_HVBAT_CELL_83_V

  • Service 22DID 1E92
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 84 voltage A3E_HVBAT_CELL_84_V

  • Service 22DID 1E93
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 85 voltage A3E_HVBAT_CELL_85_V

  • Service 22DID 1E94
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 86 voltage A3E_HVBAT_CELL_86_V

  • Service 22DID 1E95
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 87 voltage A3E_HVBAT_CELL_87_V

  • Service 22DID 1E96
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 88 voltage A3E_HVBAT_CELL_88_V

  • Service 22DID 1E97
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 89 voltage A3E_HVBAT_CELL_89_V

  • Service 22DID 1E98
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 90 voltage A3E_HVBAT_CELL_90_V

  • Service 22DID 1E99
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 91 voltage A3E_HVBAT_CELL_91_V

  • Service 22DID 1E9A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 92 voltage A3E_HVBAT_CELL_92_V

  • Service 22DID 1E9B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 93 voltage A3E_HVBAT_CELL_93_V

  • Service 22DID 1E9C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 94 voltage A3E_HVBAT_CELL_94_V

  • Service 22DID 1E9D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 95 voltage A3E_HVBAT_CELL_95_V

  • Service 22DID 1E9E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 96 voltage A3E_HVBAT_CELL_96_V

  • Service 22DID 1E9F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 97 voltage A3E_HVBAT_CELL_97_V

  • Service 22DID 1EA0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 98 voltage A3E_HVBAT_CELL_98_V

  • Service 22DID 1EA1
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 99 voltage A3E_HVBAT_CELL_99_V

  • Service 22DID 1EA2
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 100 voltage A3E_HVBAT_CELL_100_V

  • Service 22DID 1EA3
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 101 voltage A3E_HVBAT_CELL_101_V

  • Service 22DID 1EA4
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell 102 voltage A3E_HVBAT_CELL_102_V

  • Service 22DID 1EA5
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell voltage max, ID A3E_HVBAT_CELL_V_MAX_IDConfirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage min, ID A3E_HVBAT_CELL_V_MIN_IDConfirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage sum A3E_HVBAT_CELL_SUM_V

  • Service 22DID 1E3C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val4096
Range
0 to 4095.999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV battery cell voltage, maximum A3E_HVBAT_CELL_V_MAX_V2Confirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×244110000
Range
0 to 15.997 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, minimum A3E_HVBAT_CELL_V_MIN_V2Confirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×244110000
Range
0 to 15.997 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery charge A3E_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x15 = 21 → 21×100255 = 8.235294 %

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

HV battery charge, displayed A3E_HVBAT_SOC_DISPConfirmed

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x02F9 = 761 → 761100 = 7.61 %

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

HV battery coldest sensor A3E_HVBAT_T_MIN_NO

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Supported for 2017.

HV battery current, raw A3E_HVBAT_I_RAWConfirmed

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

0x02495A = 149850 → 149,850

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

HV battery highest cell A3E_HVBAT_CELL_V_MAX_NOConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x31 = 49 → 49

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery isolation resistance, negative A3E_HVBAT_ISO_NEG

  • Service 22DID 1E1A
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2014 to 2018, 2020 to 2026.

HV battery isolation resistance, positive A3E_HVBAT_ISO_POS

  • Service 22DID 1E18
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2014 to 2018, 2020 to 2026.

HV battery lowest cell A3E_HVBAT_CELL_V_MIN_NOConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x4C = 76 → 76

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery maximum power A3E_HVBAT_PWR_MAX

  • Service 22DID 1502
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2014 to 2018, 2020 to 2026.

HV battery maximum temperature A3E_BMS_T_MAXConfirmed

  • Service 22DID 1E0E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

0x57 = 87 → 87−100 = -13 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery maximum temperature, sensor number A3E_BMS_T_MAX_CELLConfirmed

  • Service 22DID 1E0E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery state of charge display A3E_CHRGR_SOC_DISPConfirmed

  • Service 22DID 1DD0
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x02 = 2 → 22 = 1 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery temperature load A3E_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

HV battery temperature, minimum A3E_BMS_T_MINConfirmed

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

0x56 = 86 → 86−100 = -14 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery temperature, minimum, cell number A3E_BMS_T_MIN_CELLConfirmed

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x3C = 60 → 60

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery voltage A3E_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

0x0D4F = 3407 → 34074 = 851.75 V

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

HV battery: circulation pump flow A3E_CIRC_PUMP_FLOWConfirmed

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV interlock detector voltage A3E_HV_INTERLOCK_DET_V

  • Service 22DID 74B9
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV interlock source current A3E_HV_INTERLOCK_SRC_I

  • Service 22DID 74BC
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

HV interlock source voltage A3E_HV_INTERLOCK_SRC_V

  • Service 22DID 74BA
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

HV system isolation resistance, negative A3E_HV_ISO_NEG_SYS

  • Service 22DID 1E19
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2014 to 2018, 2020 to 2026.

HV system isolation resistance, positive A3E_HV_ISO_POS_SYS

  • Service 22DID 1E17
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage, cylinder 1 A3E_KNOCK_SENS_V_CYL_1

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage, cylinder 3 A3E_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage:, cylinder 2 A3E_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage:, cylinder 3 A3E_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage:, cylinder 5 A3E_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor voltage:, cylinder 6 A3E_KNOCK_SENS_V_CYL_6

  • Service 22DID 13FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensors average voltage bank 1, variant 2 A3E_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Maximum charge power A3E_CHRGR_CHG_PWR_MAXConfirmed

  • Service 22DID 1DD3
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Maximum dynamic charge current limit A3E_BMS_I_CHG_LIM_DYNConfirmed

  • Service 22DID 1E1B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0001 = 1 → 1 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Maximum dynamic discharge current limit A3E_BMS_I_DCHG_LIM_DYNConfirmed

  • Service 22DID 1E1C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x00A9 = 169 → 169 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Maximum energy content of the traction battery A3E_MAX_ENERGY_CONTENTConfirmed

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

0x6D000600 = 1828718080 → 18287180801310770 = 1,395.147951 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Maximum predicted charge current limit A3E_BMS_I_CHG_LIM_PREDConfirmed

  • Service 22DID 1E1D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0000 = 0 → 0 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Maximum predicted discharge current limit A3E_BMS_I_DCHG_LIM_PREDConfirmed

  • Service 22DID 1E1E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x003F = 63 → 63 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Onboard electrical system power A3E_AUX_PWR

  • Service 22DID 1077
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2014 to 2018, 2020 to 2026.

Power efficiency A3E_CHRGR_EFFICIENCYConfirmed

  • Service 22DID 15D6
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
75 to 100.5 A
Unit
A

0xB4 = 180 → 18010+75 = 93 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Power loss battery charger A3E_CHRGR_PWR_LOSSConfirmed

  • Service 22DID 15E1
  • Module744 → 7AE
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100
Unit
Raw value

0x00 = 0 → 0×20 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

State of charge A3E_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2014 to 2016, 2020 to 2026. Not supported for 2018.

Temperature sensor for engine temperature management voltage A3E_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor, socket a A3E_OBC_T_AConfirmed

  • Service 22DID 1DDA
  • Module744 → 7AE
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498.5 °C
Unit
°C

0x0002 = 2 → 210−55 = -54.8 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Temperature, battery A3E_BATTERY_TConfirmed

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Turbocharger inlet pressure corrected value A3E_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Usable battery charge A3E_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x16 = 22 → 22 Ah

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Cells

HV battery cell voltage, #1 A3E_HVBAT_CELL_V_001Confirmed

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #2 A3E_HVBAT_CELL_V_002Confirmed

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #3 A3E_HVBAT_CELL_V_003Confirmed

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #4 A3E_HVBAT_CELL_V_004Confirmed

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #5 A3E_HVBAT_CELL_V_005Confirmed

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #6 A3E_HVBAT_CELL_V_006Confirmed

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #7 A3E_HVBAT_CELL_V_007Confirmed

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #8 A3E_HVBAT_CELL_V_008Confirmed

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #9 A3E_HVBAT_CELL_V_009Confirmed

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #10 A3E_HVBAT_CELL_V_010Confirmed

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #11 A3E_HVBAT_CELL_V_011Confirmed

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #12 A3E_HVBAT_CELL_V_012Confirmed

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #13 A3E_HVBAT_CELL_V_013Confirmed

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #14 A3E_HVBAT_CELL_V_014Confirmed

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #15 A3E_HVBAT_CELL_V_015Confirmed

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #16 A3E_HVBAT_CELL_V_016Confirmed

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #17 A3E_HVBAT_CELL_V_017Confirmed

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #18 A3E_HVBAT_CELL_V_018Confirmed

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #19 A3E_HVBAT_CELL_V_019Confirmed

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #20 A3E_HVBAT_CELL_V_020Confirmed

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #21 A3E_HVBAT_CELL_V_021Confirmed

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #22 A3E_HVBAT_CELL_V_022Confirmed

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #23 A3E_HVBAT_CELL_V_023Confirmed

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #24 A3E_HVBAT_CELL_V_024Confirmed

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #25 A3E_HVBAT_CELL_V_025Confirmed

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #26 A3E_HVBAT_CELL_V_026Confirmed

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #27 A3E_HVBAT_CELL_V_027Confirmed

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #28 A3E_HVBAT_CELL_V_028Confirmed

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #29 A3E_HVBAT_CELL_V_029Confirmed

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #30 A3E_HVBAT_CELL_V_030Confirmed

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #31 A3E_HVBAT_CELL_V_031Confirmed

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #32 A3E_HVBAT_CELL_V_032Confirmed

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #33 A3E_HVBAT_CELL_V_033Confirmed

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #34 A3E_HVBAT_CELL_V_034Confirmed

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #35 A3E_HVBAT_CELL_V_035Confirmed

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #36 A3E_HVBAT_CELL_V_036Confirmed

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #37 A3E_HVBAT_CELL_V_037Confirmed

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #38 A3E_HVBAT_CELL_V_038Confirmed

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #39 A3E_HVBAT_CELL_V_039Confirmed

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #40 A3E_HVBAT_CELL_V_040Confirmed

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #41 A3E_HVBAT_CELL_V_041Confirmed

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #42 A3E_HVBAT_CELL_V_042Confirmed

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #43 A3E_HVBAT_CELL_V_043Confirmed

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #44 A3E_HVBAT_CELL_V_044Confirmed

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #45 A3E_HVBAT_CELL_V_045Confirmed

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #46 A3E_HVBAT_CELL_V_046Confirmed

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #47 A3E_HVBAT_CELL_V_047Confirmed

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #48 A3E_HVBAT_CELL_V_048Confirmed

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #49 A3E_HVBAT_CELL_V_049Confirmed

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #50 A3E_HVBAT_CELL_V_050Confirmed

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #51 A3E_HVBAT_CELL_V_051Confirmed

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #52 A3E_HVBAT_CELL_V_052Confirmed

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #53 A3E_HVBAT_CELL_V_053Confirmed

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #54 A3E_HVBAT_CELL_V_054Confirmed

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #55 A3E_HVBAT_CELL_V_055Confirmed

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #56 A3E_HVBAT_CELL_V_056Confirmed

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #57 A3E_HVBAT_CELL_V_057Confirmed

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #58 A3E_HVBAT_CELL_V_058Confirmed

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #59 A3E_HVBAT_CELL_V_059Confirmed

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #60 A3E_HVBAT_CELL_V_060Confirmed

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #61 A3E_HVBAT_CELL_V_061Confirmed

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #62 A3E_HVBAT_CELL_V_062Confirmed

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #63 A3E_HVBAT_CELL_V_063Confirmed

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #64 A3E_HVBAT_CELL_V_064Confirmed

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #65 A3E_HVBAT_CELL_V_065Confirmed

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #66 A3E_HVBAT_CELL_V_066Confirmed

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #67 A3E_HVBAT_CELL_V_067Confirmed

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #68 A3E_HVBAT_CELL_V_068Confirmed

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #69 A3E_HVBAT_CELL_V_069Confirmed

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #70 A3E_HVBAT_CELL_V_070Confirmed

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #71 A3E_HVBAT_CELL_V_071Confirmed

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #72 A3E_HVBAT_CELL_V_072Confirmed

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #73 A3E_HVBAT_CELL_V_073Confirmed

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #74 A3E_HVBAT_CELL_V_074Confirmed

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #75 A3E_HVBAT_CELL_V_075Confirmed

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #76 A3E_HVBAT_CELL_V_076Confirmed

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #77 A3E_HVBAT_CELL_V_077Confirmed

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #78 A3E_HVBAT_CELL_V_078Confirmed

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #79 A3E_HVBAT_CELL_V_079Confirmed

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #80 A3E_HVBAT_CELL_V_080Confirmed

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #81 A3E_HVBAT_CELL_V_081Confirmed

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #82 A3E_HVBAT_CELL_V_082Confirmed

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #83 A3E_HVBAT_CELL_V_083Confirmed

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #84 A3E_HVBAT_CELL_V_084Confirmed

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #85 A3E_HVBAT_CELL_V_085Confirmed

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #86 A3E_HVBAT_CELL_V_086Confirmed

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #87 A3E_HVBAT_CELL_V_087Confirmed

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #88 A3E_HVBAT_CELL_V_088Confirmed

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #89 A3E_HVBAT_CELL_V_089Confirmed

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #90 A3E_HVBAT_CELL_V_090Confirmed

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #91 A3E_HVBAT_CELL_V_091Confirmed

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #92 A3E_HVBAT_CELL_V_092Confirmed

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #93 A3E_HVBAT_CELL_V_093Confirmed

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #94 A3E_HVBAT_CELL_V_094Confirmed

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #95 A3E_HVBAT_CELL_V_095Confirmed

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

HV battery cell voltage, #96 A3E_HVBAT_CELL_V_096Confirmed

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Internal

Average battery consumption A3E_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x30 = 48 → 48 A

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Estimated electric power reserve A3E_RANGE_EST_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Climate

A/C compressor torque, requested A3E_AC_COMP_TConfirmed

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Air conditioning compressor shutdown requirement A3E_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENTConfirmed

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Ambient air temperature A3E_AAT_7E0_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Ambient temperature A3E_AAT_V2Confirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

0x0000 = 0 → 0128 = 0 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Barometric pressure A3E_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Interior air temperature A3E_INTERIOR_TConfirmed

  • Service 22DID 2613
  • Module714
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 °C
Unit
°C

0x0144 = 324 → 32410 = 32.4 °C

Confirmed for 2017. In testing for 2014 to 2016, 2020 to 2026. Not supported for 2018.

Outside humidity A3E_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Outside temperature A3E_AATConfirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

0x45 = 69 → 692 = 34.5 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Recirculation flap actual position A3E_MQB_RECIRC_FLAP_ACTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x5E = 94 → 942 = 47 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Recirculation flap fresh air threshold A3E_MQB_RECIRC_FLAP_FRESH_THRConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00AD = 173 → 173

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Recirculation flap target position A3E_MQB_RECIRC_FLAP_TRGConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00C8 = 200 → 200

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Recirculation flap threshold A3E_MQB_RECIRC_FLAP_THRConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x035E = 862 → 862

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clocks

Time since engine start A3E_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x011A = 282 → 282 s

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Control

Absolute pedal position, drive A3E_APP_DConfirmed

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

0x25 = 37 → 372.55 = 14.509804 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2018.

Accelerator pedal release detection threshold voltage A3E_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Air gab vacuum sensor A3E_AIR_GAB_VACUUM_SNSConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Brake booster low pressure, actual A3E_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Brake booster pressure A3E_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Brake booster raw pressure A3E_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Brake disk drying A3E_BDD_ACTIVEConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Brake disk drying, odometer at last activation A3E_BDD_ODOConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x01A48E = 107662 → 107,662 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Brake pedal position A3E_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Brake pressure A3E_BRAKE_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Brake pressure A3E_BRAKE_P_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Brake pressure A3E_MQB_TCM_BRAKE_PConfirmed

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Brake pressure sensor A3E_BRAKE_P_SNSConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Downshift point adaptation voltage A3E_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2014 to 2018, 2020 to 2026.

Electronic differential lock: active A3E_EDL_ACTIVEConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Electronic differential lock: front left brake temperature A3E_EDL_FR_L_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Electronic differential lock: front right brake temperature A3E_EDL_FR_R_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Electronic differential lock: rear left brake temperature A3E_EDL_RR_L_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Electronic differential lock: rear right brake temperature A3E_EDL_RR_R_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Hydraulic brake booster: active A3E_HYD_BRAKE_BOOST_ACTIVEConfirmed

  • Service 22DID 1810
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Parking brake, air gap - left A3E_PARKING_BRAKE_AIR

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Parking brake, air gap - right A3E_PARKING_BRAKE_AIR_GAP

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Pressure in brake servo unit A3E_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Requested brake torque, auxiliary system A3E_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared A3E_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1308 = 4872 → 4,872 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017 to 2018.

Distance traveled while mil was activated A3E_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1288 = 4744 → 4,744 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Number of warm-ups since diagnostic trouble codes cleared A3E_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x51 = 81 → 81

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

ECU

Misfires, cylinder 2 A3E_MISFIRES__CYL__2Confirmed

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x539D = 21405 → 21,405

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Misfires, cylinder 4 A3E_MISFIRES__CYL__4Confirmed

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x3B4D = 15181 → 15,181

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Engine

A/C compressor torque A3E_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

A/C refrigerant pressure A3E_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Adaptation of loss torque A3E_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Adaptation of throttle valve A3E_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder1 fast diagnosis A3E_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder1 slow diagnosis A3E_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder2 fast diagnosis A3E_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder2 slow diagnosis A3E_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder3 fast diagnosis A3E_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder3 slow diagnosis A3E_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder4 fast diagnosis A3E_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation val.cylinder4 slow diagnosis A3E_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptive mode A3E_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Air conditioning compressor pressure, linear raw value A3E_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air conditioning compressor refrigerant pressure A3E_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air conditioning compressor torque A3E_AC_COMP_TQ

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Air conditioning compressor torque A3E_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Air conditioning refrigerant pressure A3E_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air filling A3E_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Air leakage A3E_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air mass, actual value, mg/stroke A3E_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air mass, specified value A3E_AIR_MASS_SPEC

  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Air pollution level A3E_CLIMATE_AIR_POLUTION_LVLConfirmed

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Ambient air pressure A3E_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Ambient air temperature A3E_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x95 = 149 → 1492−50 = 24.5 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Ambient air temperature, v1 A3E_AAT_V1Confirmed

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

0x0A0D = 2573 → 2573×0.18−460 = 3.14 °F

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Ambient temperature A3E_AAT_7E0

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Ambient temperature A3E_AAT_7E0_2

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 1, maximum temperature A3E_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 2, maximum temperature A3E_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Automatic engine starts counter A3E_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Automatic transmission fluid temperature A3E_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x27 = 39 → 39 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Aux. hydraulic pump internal temperature A3E_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Aux. hydraulic pump, current A3E_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Average ignition timing angle delay adjustment A3E_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Avg. injection time A3E_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Avg. injection time A3E_AVG_INJ_TIME_7E0

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Basic correction factor:, cylinder 1, filtered A3E_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Basic correction factor:, cylinder 2, filtered A3E_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Basic correction factor:, cylinder 3, filtered A3E_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Basic correction factor:, cylinder 4, filtered A3E_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Battery module controller temperature, 3 A3E_BMS_BMCE_T3Confirmed

  • Service 22DID 180E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x01 = 1 → 1−50 = -49 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Boost press before throttle: calculated actual value A3E_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACTConfirmed

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

0x0000 = 0 → 0×2500 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Boost pressure actuator, commanded duty A3E_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Boost pressure commanded A3E_PQ35_BOOST_P_CMDConfirmed

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Boost pressure, actual A3E_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Boost pressure, actual A3E_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Boost pressure, target A3E_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Boost regulation duty, commanded value A3E_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bypass valve high pressure turbine inlet, activation A3E_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bypass valve high pressure turbine inlet, actual value A3E_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bypass valve high pressure turbine inlet, offset closed A3E_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bypass valve high pressure turbine inlet, offset open A3E_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bypass valve high pressure turbine inlet, target value A3E_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Bze_q_elad A3E_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

Bze_q_lad A3E_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

Cabin temperature A3E_CABIN_T

  • Service 22DID 2613
  • Module714 → 77E
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2014 to 2016, 2018, 2020 to 2026.

Cabin temperature A3E_CABIN_T_V2Confirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x008E = 142 → 14210 = 14.2 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2018.

Camshaft adaptation exhaust bank 1, phase position A3E_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation intake bank 1, phase position A3E_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation intake, phase position A3E_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation, counter due to knock A3E_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation, exhaust bank 1, phase position A3E_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation, intake bank 1, phase position A3E_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adaptation, intake deviation A3E_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment intake bank 1, activation % A3E_CAM_ADJ_INT_BANK_1

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment intake test bank 1 A3E_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment outlet test bank 1 A3E_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, exhaust bank 1, actual value A3E_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, exhaust bank 1, specified value A3E_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, exhaust bank 2, actual value A3E_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, exhaust bank 2, specified value A3E_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, exhaust, specified value A3E_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, intake bank 1, actual value A3E_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, intake bank 1, specified value A3E_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, intake, actual value A3E_CAM_ADJ_INT_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft adjustment, intake, specified value A3E_CAM_ADJ_INT_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Camshaft end position A3E_PQ35_CAMS_ENDConfirmed

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

0x000F = 15 → 155 = 3 °

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Camshaft position, deviation from the base position A3E_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Cat. converter oxygen storage capacity measured A3E_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Cat. temperature, bank 1 A3E_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Cat. temperature, bank 2 A3E_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Centrifugal oil temperature A3E_PQ35_CENTRIFUGAL_OIL_TConfirmed

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Chain elongation inlet, mileage at last adaptation A3E_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Chain elongation outlet, mileage at last adaptation A3E_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 A3E_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Chain elongation, no of valid initial values, intake bank 1 A3E_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Clutch #1 maximum temperature A3E_PQ35_CLUTCH_1_MAXIMUM_TConfirmed

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

0x012B = 299 → 299 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch #2 maximum temperature A3E_PQ35_CLUTCH_2_MAXIMUM_TConfirmed

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

0x00AD = 173 → 173 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 temperature A3E_PQ35_CLUTCH_1_TConfirmed

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

0x05 = 5 → 5 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity A3E_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTYConfirmed

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 temperature protection warning 1 quantity A3E_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTYConfirmed

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 temperature protection warning 2 quantity A3E_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTYConfirmed

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 temperature A3E_PQ35_CLUTCH_2_TConfirmed

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

0x05 = 5 → 5 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity A3E_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTYConfirmed

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 temperature protection warning 1 quantity A3E_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTYConfirmed

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 temperature protection warning 2 quantity A3E_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTYConfirmed

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch center central plate temperature A3E_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Commanded crankshaft torque A3E_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017. Supported for 2018.

Compression test cylinder 2 A3E_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Compression test, cylinder 1 A3E_COMPRESSION_TEST_CYL_1

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Compression test, cylinder 2 A3E_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Compression test, cylinder 3 A3E_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Compression test, cylinder 4 A3E_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Control module temperature A3E_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Control module temperature A3E_MQB_TCM_ECU_TConfirmed

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x05 = 5 → 5 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Converter loss torque A3E_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Coolant circulation pump, activation A3E_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant circulation pump, control A3E_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant fan 1 activation, $1117 A3E_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant fan 1, activation A3E_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant fan 1, activation A3E_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant fan 2, activation A3E_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant fan, requested by A/C A3E_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Coolant shut-off valve, closed A3E_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at engine outlet, calculated A3E_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at engine outlet, calculated A3E_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_V2

  • Service 22DID 4490
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at engine outlet, calculated A3E_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at engine start A3E_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at engine start A3E_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet A3E_COOLANT_TConfirmed

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0E61 = 3681 → 368110−273.1 = 95 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Coolant temperature at radiator outlet A3E_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet 2 A3E_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet v.1 A3E_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet, actual value A3E_ECT_RADIATOR_OUTLET_ACT

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet, actual value A3E_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature at radiator outlet, specified value A3E_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature difference between engine and radiator A3E_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature linear A3E_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2929710000000−48
Range
-48 to 143.9978 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature modeled value A3E_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature, maximum value A3E_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Coolant temperature, minimum value A3E_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Cooling outlet temperature A3E_BMS_COOL_OUT_TConfirmed

  • Service 22DID 181D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x5A = 90 → 90−50 = 40 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Correction factor of oil temperature for engine protection A3E_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Counter steer support A3E_CNT_STEER_SUPPORT_ACTIVEConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Counter steer support, steering torque A3E_CNT_STEER_SUPPORT_STEERING_TRQConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

0x0000 = 0 → 01000 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Crankshaft rotation angle when closing the quantity control valve A3E_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Critical engine oil level A3E_PQ35_OIL_LVL_CRITConfirmed

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

0x0C1B = 3099 → 3099250 = 12.396 mm

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 A3E_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 A3E_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 A3E_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Current N215 pressure control valve 1 A3E_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current N216 pressure control valve 2 A3E_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current N217 pressure control valve 3 A3E_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current N218 pressure control valve 4 A3E_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current N233 pressure control valve 5 A3E_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current solenoid A3E_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Current type of driver counter A3E_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Cylinder 1 internal torque A3E_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Cylinder 2 internal torque A3E_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Cylinder 3 internal torque A3E_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Cylinder 4 internal torque A3E_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Cylinder block temperature sensor A3E_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Cylinder head temperature A3E_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2014 to 2018, 2020 to 2026.

Desired torque raw A3E_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Diesel particulate filter exhaust gas flow volume A3E_MQB_DPF_EXH_VOLConfirmed

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Direct injections counter A3E_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Drive motor current A3E_MOTOR_I

  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Drive motor speed A3E_MOTOR_RPM_ECM

  • Service 22DID 149A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Drive motor torque A3E_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Driver demand torque A3E_MQB_TCM_DRIVER_DEMAND_TORQUEConfirmed

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Driving mode sensor, hall sensor a A3E_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Driving position A3E_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Driving resistance index A3E_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Dynamic average of ignition angle delay adjustment A3E_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Ea888b boost pressure control, adaptation value 0 A3E_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Ea888b boost pressure control, adaptation value 1 A3E_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Ea888b boost pressure control, adaptation value 2 A3E_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Ea888b boost pressure control, adaptation value 3 A3E_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Ea888b boost pressure regulator, commanded A3E_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for toque reduction, cylinder 1 A3E_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for toque reduction, cylinder 2 A3E_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for toque reduction, cylinder 3 A3E_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for toque reduction, cylinder 4 A3E_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder 1 A3E_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder 2 A3E_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder 3 A3E_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder 4 A3E_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 A3E_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, total, cylinder 1 A3E_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, total, cylinder 2 A3E_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, total, cylinder 3 A3E_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter, total, cylinder 4 A3E_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Effective injection duration A3E_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

EGT after catalyst, model bank b A3E_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Electric additional coolant pump control, high circle A3E_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Energy balance of last driving cycle A3E_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

Energy content A3E_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2014 to 2018, 2020 to 2026.

Engine air mass, specified value A3E_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Engine compartment temperature raw value A3E_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017. Supported for 2018.

Engine drag torque A3E_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine oil level A3E_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Engine oil level A3E_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Engine oil level current value A3E_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Engine oil pressure A3E_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 2014 to 2018, 2020 to 2026.

Engine oil sump temperature A3E_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2014 to 2018, 2020 to 2026.

Engine oil temperature A3E_EOT_7E0

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine oil temperature A3E_EOT_7E0_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine oil temperature measured value A3E_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine oil temperature sensor 2 A3E_EOT_SENS_2

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine oil temperature, pulse sensor A3E_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine outlet coolant temperature calculated A3E_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Engine protection, torque limit A3E_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine radiator fan request A3E_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature control actuator A3E_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature management actuator, after-run stop A3E_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature management actuator, duty cycle activation A3E_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature management actuator, raw value A3E_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature management actuator, specified value A3E_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Engine temperature management actuator, stop open A3E_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Engine torque A3E_ENG_TQ

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine torque A3E_ENG_TQ_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine torque A3E_ENGINE_TORQUE

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine torque A3E_MQB_TCM_ENGINE_TORQUEConfirmed

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Engine torque limitation A3E_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Engine torque limitation A3E_MQB_TCM_ENGINE_TORQUE_LIMITATIONConfirmed

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Engine torque loss A3E_MQB_TCM_ENGINE_TORQUE_LOSSConfirmed

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Excessive temperature protection A3E_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Exhaust camshaft, adaptation bias A3E_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Exhaust camshaft, adaptation sensor tolerance A3E_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas jet volume in particle filter A3E_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature A3E_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature - calculated after catalyst A3E_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature before catalyst A3E_EXHAUST_GAS_T_BEFORE_CATALYSTConfirmed

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

0x2B7C = 11132 → 1113250−193.93 = 28.71 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Exhaust gas temperature before catalytic converter A3E_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature before the front catalytic converter, model value A3E_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 1 A3E_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 1 A3E_EXH_GAS_T_SENS_1_7E0

  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 1, bank 2 A3E_EXH_GAS_T_SENS_1_2

  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 3 A3E_EXH_GAS_T_SENS_3

  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 3, bank 2 A3E_EXH_GAS_T_SENS_3_2

  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature sensor 4 A3E_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust gas temperature, sensor 4, bank 2 A3E_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Exhaust temperature before the catalyst, modeled A3E_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Front left deflector temperature A3E_CLIMATE_FR_L_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x46 = 70 → 703 = 23.333333 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front left temperature flap actual value A3E_CLIMATE_FR_L_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x71 = 113 → 1132 = 56.5 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front right deflector temperature A3E_CLIMATE_FR_R_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x49 = 73 → 733 = 24.333333 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front right temperature flap actual value A3E_CLIMATE_FR_R_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x6C = 108 → 1082 = 54 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Fuel metering valve position A3E_PQ35_FUEL_METERConfirmed

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Fuel temperature A3E_PQ35_FUEL_TConfirmed

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0000 = 0 → 010−273.1 = -273.1 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Generator current A3E_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2014 to 2018, 2020 to 2026.

Generator load A3E_PQ35_GEN_LOADConfirmed

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Generator load normalized value A3E_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Generator load signal A3E_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Generator load signal A3E_GEN_LOAD_SIG_7E0

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Generator load signal A3E_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Generator performance A3E_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2014 to 2018, 2020 to 2026.

Generator torque request A3E_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Heater circulation pump, nominal value A3E_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Heater support pump, specified value A3E_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Height correction A3E_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

High pressure control, adaptation A3E_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

High pressure EGR actuator, activation A3E_HIGH_P_EGR_ACTUATOR

  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

High pressure regulation, adaptation value A3E_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Hill descent control A3E_HDC_ACTIVEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Hill descent control, incline A3E_HDC_INCLINEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

ID of current driving program A3E_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

IGA_CYL_KNK, 0 A3E_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_CYL_KNK, 1 A3E_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_CYL_KNK, 2 A3E_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_CYL_KNK, 3 A3E_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_IGC, 0 A3E_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_IGC, 1 A3E_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_IGC, 2 A3E_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

IGA_IGC, 3 A3E_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Ignition angle current cylinder, actual value A3E_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Ignition timing angle retard, cylinder 4 A3E_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 1 A3E_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 2 A3E_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 2 A3E_INJ_AMOUNT_DEV_CYL_2_7E0

  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 3 A3E_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 4 A3E_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection amount deviation cylinder 5 A3E_INJ_AMOUNT_DEV_CYL_5

  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection quantity deviation, cylinder 2 A3E_INJ_QTY_DEV_CYL_2

  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injection quantity deviation, cylinder 5 A3E_INJ_QTY_DEV_CYL_5

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Injector 1 rail pressure calibration point 2 A3E_PQ35_INJ_1_RAIL_P_2Confirmed

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Injector 2, rail pressure calibration point 1 A3E_INJ_2_RAIL_P_1

  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Injector 2, rail pressure calibration point 2 A3E_INJ_2_RAIL_P_2

  • Service 22DID 10DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Injector 2: rail pressure calibration point 2 A3E_INJ_2_RAIL_P_CAL_PT_2_1474

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Injector 4, rail pressure calibration point 2 A3E_INJ_4_RAIL_P_2

  • Service 22DID 10D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Injector 5, rail pressure calibration point 2 A3E_INJ_5_RAIL_P_2

  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Injector 5, rail pressure calibration point 3 A3E_INJ_5_RAIL_P_3

  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Injector 7: rail pressure calibration point 1 A3E_INJ_7_RAIL_P_CAL_PT_1

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Inlet flaps - actual value A3E_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Inlet flaps - requested value A3E_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Intake air temperature A3E_IAT_7E0

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Intake air temperature before throttle valve, raw value A3E_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Intake air temperature in intake manifold A3E_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Intake air temperature raw value A3E_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Intake camshaft, adaptation bias A3E_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Intake camshaft, adaptation sensor tolerance A3E_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Intake manifold pressure raw value A3E_INT_MANIFOLD_P_RAW

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Intake manifold pressure, commanded A3E_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Intake manifold pressure, corrected A3E_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Intake manifold runner control, acknowledgment A3E_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Intake manifold runner control, activation A3E_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Intake model air mass flow filtered value A3E_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Intake phase deviation, actual value A3E_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Integrated mass of air since engine start A3E_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Integrated mass of air since the first engine start A3E_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Intercooler air output temperature A3E_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Kick down A3E_MQB_TCM_KICK_DOWNConfirmed

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Knock retard 2 A3E_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Knock retard 4 A3E_KNOCK_RETARD_4

  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor 1 test A3E_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor 2 test A3E_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor 3 test A3E_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor 4 test A3E_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 1 A3E_KNOCK_SENS_CYL_1

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 1 A3E_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 2 A3E_KNOCK_SENS_CYL_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 2 A3E_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 2 A3E_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 3 A3E_KNOCK_SENS_CYL_3

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 3 A3E_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 4 A3E_KNOCK_SENS_CYL_4

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Knock sensor, cylinder 4 A3E_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Lambda output value A3E_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Lambda, actual value A3E_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Launch control counter, variant 1 A3E_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Launch control counter, variant 2 A3E_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Leg deflector temperature A3E_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x41 = 65 → 653 = 21.666667 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Long term fuel trim at idle, direct injection A3E_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim at idle, port injection A3E_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Long-term adaptation of intake manifold injection A3E_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Long-term adaptation of intake manifold injection at idle A3E_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Lost torque adaptation A/C + driving mode A3E_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Lost torque adaptation driving mode A3E_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Low pressure EGR closing A3E_LOW_P_EGR_CLOSING

  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-252048+100
Range
-699 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

M009, desired solenoid out 10 A3E_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

M009, desired solenoid out 11 A3E_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

M009, desired solenoid out 12 A3E_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

M009, desired solenoid out 13 A3E_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

M009, desired solenoid out 14 A3E_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Main cat oxygen storage capacity age correction factor A3E_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Main injection duration A3E_PQ35_MAIN_INJ_DURATIONConfirmed

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

0x6075 = 24693 → 24693×0.41000 = 9.8772 ms

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Manifold absolute pressure, raw value A3E_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Manual engine starts counter A3E_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Mass air flow over throttle valve A3E_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mass air flow rate A3E_MAF_RATE

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mass air flow through throttle A3E_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mass air flow, commanded A3E_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mass airflow sensor 1 bank 1 raw value A3E_MQB_MAF_1_B1_RAWConfirmed

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Mass flow through throttle valve A3E_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Max permissible engine torque A3E_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Maximum ECU temperature A3E_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Maximum filling correction factor from knock control A3E_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Maximum oil level for the service interval A3E_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Mean engine air mass A3E_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mean injection quantity A3E_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Mean injection quantity A3E_MEAN_INJ_QUANTITYConfirmed

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

0x340B = 13323 → 13323100 = 133.23

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Mileage with ECU installed A3E_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Minimum oil level for the service interval A3E_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Misfires / 1000 revolutions, cylinder 1 A3E_MISFIRES_1000REV_C1Confirmed

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Misfires / 1000 revolutions, cylinder 2 A3E_MISFIRES_1000REV_C2Confirmed

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Misfires counter:, cylinder 1 A3E_MIS_CNT_1

  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires counter:, cylinder 2 A3E_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires counter:, cylinder 3 A3E_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires counter:, cylinder 5 A3E_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires counter:, cylinder 6 A3E_MIS_CNT_6

  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions 2 A3E_MIS_PER_1000_2_7E0_7E0

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions 4 A3E_MIS_PER_1000_REVOLUTIONS_4_7E0

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection A3E_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 2 A3E_MIS_PER_1000_2_7E0

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection A3E_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 3 A3E_MIS_PER_1000_3_7E0

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection A3E_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection A3E_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires total A3E_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires total A3E_MISFIRES_TOTALConfirmed

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Misfires, cylinder 1 A3E_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 1 A3E_MIS_1_V2Confirmed

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x4EF3 = 20211 → 20,211

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Misfires, cylinder 1 A3E_MISFIRES_C1_7E0

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 2 A3E_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 2 A3E_MISFIRES_C2

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 3 A3E_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 3 A3E_MISFIRES_C3_7E0

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 3 A3E_MISFIRES_C3_ECMConfirmed

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x5B1D = 23325 → 23,325

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Misfires, cylinder 4 A3E_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires, cylinder 4 A3E_MISFIRES_C4

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Mixture adaptation factor at partial load A3E_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

N_32 A3E_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

NL_PRE, 0 A3E_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

NL_PRE, 1 A3E_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

NL_PRE, 2 A3E_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

NL_PRE, 3 A3E_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2014 to 2018, 2020 to 2026.

Number of injections A3E_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded A3E_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Number of warnings due to increased centrifugal oil temperature A3E_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

NV energy requirement A3E_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2014 to 2018, 2020 to 2026.

Oil ash limit A3E_OIL_ASH_LIM

  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Oil ash residue A3E_OIL_ASH_RESIDUE

  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×3.052e-7
Range
0 to 1310
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Oil level A3E_OIL_LEVELConfirmed

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x4D76 = 19830 → 198302500 = 7.932 cm

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Oil level method 1 A3E_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level method 2 A3E_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level method 3 A3E_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level test method 1 A3E_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level test method 2 A3E_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level test method 3 A3E_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil level, average dynamic value A3E_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Oil level, last dynamic value A3E_OIL_LEVEL_LASTConfirmed

  • Service 22DID 15B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

0x1D50 = 7504 → 7504250 = 30.016 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Oil level, static measured A3E_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Oil level, static measurement A3E_OIL_LEVEL_STATIC_7E0

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Oil p A3E_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure actual A3E_MQB_TCM_EOP_ACTUALConfirmed

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

0x0000 = 0 → 0×10010000 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Oil pressure actual current A3E_MQB_TCM_EOP_ACTUAL_IConfirmed

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x0014 = 20 → 2010 = 2 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Oil pressure control valve activation pulse duty factor A3E_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure control valve, activation pulse duty factor A3E_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure sensor raw value A3E_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status A3E_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure sensor, raw value A3E_OIL_P_SENS_RAW_7E0

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure switch activation, high pressure A3E_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure switch for high pressure, closed A3E_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure switch for low pressure, closed A3E_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure switch for piston-cooling jets, closed A3E_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure switch valve activation A3E_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure target A3E_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure target A3E_OIL_P_TGT_7E0

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio A3E_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure valve switch, control A3E_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure, actual value A3E_OIL_P_ACT_7E0

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure, actual value A3E_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Oil pressure, actual value A3E_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Oil temperature A3E_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Oil temperature variant A3E_PQ35_OIL_T_2Confirmed

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0xFFD0 = 65488 → 6548810−273.1 = 6,275.7 °C

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Oil thermal wear A3E_DASH_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x007B = 123 → 123 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Oil warning threshold A3E_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2014 to 2018, 2020 to 2026.

Open cam shaft angle at quantity control valve A3E_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Outside temperature A3E_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Outside temperature, system calculated A3E_OUTSIDE_T_SYSTEMConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x44 = 68 → 682−50 = -16 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Overall energy balance A3E_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

Oxygen control, adaptation value at part. load A3E_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature A3E_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Particle sensor, time in op.mode measurement A3E_PARTICLE_SENS_TIME

  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Pilot injection 1, activation start A3E_PRE_INJ_1_ACTIVATION

  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Pilot injection 2 duration A3E_PQ35_PRE_INJ_2_DURATIONConfirmed

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

0x0000 = 0 → 0×0.41000 = 0 ms

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Pilot injection 2, activation start A3E_PRE_INJ_2_ACTIVATION

  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Pilot injection 3 start A3E_PRE_INJ_3_START

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219731000000
Range
-720 to 719 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Pilot injection 3, activation duration A3E_PRE_INJ_3_ACTIVATION

  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Pilot injection 3, activation start A3E_PRE_INJ_3_ACTIVATION_START

  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Piston cooling nozzles, control A3E_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Piston-cooling jets, activation A3E_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Port injection injections counter A3E_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Post injection 1 A3E_POST_INJ_1

  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Post injection 1 A3E_POST_INJ_1_7E0

  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Post injection 2 A3E_POST_INJ_2

  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Post injection 2 A3E_POST_INJ_2_7E0_7E0

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Post injection 3 A3E_POST_INJ_3

  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Post injection 3 A3E_POST_INJ_3_7E0

  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Post-injection 2, activation duration A3E_POST_INJ_2_7E0

  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Pressure before throttle valve - actual value A3E_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Pressure before throttle valve - sensor measured A3E_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Pressure supply actual pressure A3E_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed

  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x1301 = 4865 → 4865100 = 48.65 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Pressure supply actual pressure analog digital value A3E_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUEConfirmed

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0A03 = 2563 → 2,563

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 A3E_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 A3E_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 A3E_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Radiator fan 1, commanded duty A3E_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Radiator fan 2, commanded duty A3E_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Radiator fan actual duty A3E_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Radiator fan commanded duty A3E_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rated drive torque A3E_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Reached maximum temperature A3E_PQ35_REACHED_MAXIMUM_TConfirmed

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x005C = 92 → 92 °C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rear cat converter temperature, main catalytic converter model value A3E_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Reducing agent tank volume, act. value filtered A3E_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Refrigerant pressure A3E_CLIMATE_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x0B = 11 → 115 = 2.2 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Regulation factor total A3E_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Relative load value A3E_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Relay for reserve coolant pump status A3E_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Requested torque, amount for auxiliary units A3E_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Reserve torque A3E_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Result of crankcase ventilation test, fail A3E_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Result of crankcase ventilation test, successful A3E_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Route data, active A3E_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Secondary air injection sensor 1 A3E_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_H, 0 A3E_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_H, 2 A3E_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_H, 3 A3E_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_L, 0 A3E_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_L, 2 A3E_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_L, 3 A3E_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_MID, 0 A3E_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_MID, 1 A3E_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER_MID, 2 A3E_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER, 1 A3E_SEG_AD_MMV_ER_1

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER, 2 A3E_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

SEG_AD_MMV_ER, 3 A3E_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Sensor for particle filter differential pressure, raw value A3E_SENS_PARTICLE_FLT_P

  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Service limit A3E_SERVICE_LIM

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Service limit A3E_SERVICE_LIM_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017. Supported for 2018.

SIM card, SIM card in main unit A3E_SIM_CARD_SIM_CARD

  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Spark efficiency deviation at idle, maximum A3E_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Spark efficiency deviation at part load, maximum A3E_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Stop signal switch A3E_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Sum of misfires counter A3E_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Tank fill level diagnostic reference value A3E_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

TCO_1_ST A3E_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

TCO_1_SYS A3E_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature after evaporator A3E_CLIMATE_T_AFTER_EVAPConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val3
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Temperature at air conditioner heat exchanger output A3E_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 1 A3E_T_SENS_1

  • Service 22DID 1EAE
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 2 A3E_T_SENS_2

  • Service 22DID 1EAF
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 3 A3E_T_SENS_3

  • Service 22DID 1EB0
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 4 A3E_T_SENS_4

  • Service 22DID 1EB1
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 5 A3E_T_SENS_5

  • Service 22DID 1EB2
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 6 A3E_T_SENS_6

  • Service 22DID 1EB3
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 7 A3E_T_SENS_7

  • Service 22DID 1EB4
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 8 A3E_T_SENS_8

  • Service 22DID 1EB5
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 9 A3E_T_SENS_9

  • Service 22DID 1EB6
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 10 A3E_T_SENS_10

  • Service 22DID 1EB7
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 11 A3E_T_SENS_11

  • Service 22DID 1EB8
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 12 A3E_T_SENS_12

  • Service 22DID 1EB9
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 13 A3E_T_SENS_13

  • Service 22DID 1EBA
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 14 A3E_T_SENS_14

  • Service 22DID 1EBB
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 15 A3E_T_SENS_15

  • Service 22DID 1EBC
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 16 A3E_T_SENS_16

  • Service 22DID 1EBD
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor 17 A3E_T_SENS_17

  • Service 22DID 7425
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor for engine temperature management A3E_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Temperature sensor for engine temperature management, target value A3E_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Test of catalytic converter status, canceled A3E_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Test of catalytic converter, measured value A3E_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Thermostat, actual A3E_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Thermostat, commanded A3E_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Throttle regulator nominal value A3E_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

TI_1_MPI, 0 A3E_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_1_MPI, 1 A3E_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_1_MPI, 2 A3E_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_1_MPI, 3 A3E_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_1, 1 A3E_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_1, 2 A3E_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_1, 3 A3E_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_2, 0 A3E_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_2, 1 A3E_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_2, 2 A3E_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_2, 3 A3E_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_3, 0 A3E_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_3, 1 A3E_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_3, 2 A3E_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

TI_MES4_PLS_3, 3 A3E_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Time in after-run A3E_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Time since reset A3E_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation after chain replacement, exhaust bank 1 A3E_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation after chain replacement, intake bank 1 A3E_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation after other repairs, intake bank 1 A3E_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation after other repairs, intake bank 1 A3E_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation current value exhaust bank 1 A3E_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Timing deviation current value intake bank 1 A3E_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Torque converter: torque loss A3E_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque factor A3E_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Torque increase request from ESP A3E_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque limitation A3E_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque limitation A3E_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque limitation A3E_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque limitation, clutch protection A3E_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque loss adaptation A3E_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque loss adaptation at idle A3E_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque loss adaptation, A/C compressor A3E_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque reduction due to exhaust temperature A3E_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.276
Unit
Number

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Torque reduction request from ESP A3E_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque request, sum of auxiliary aggregate A3E_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque transmitting function, ratio A3E_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Total mass of gasoline and ethyl alcohol in oil A3E_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Transmission drag torque A3E_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Transmission fluid temperature, calculated A3E_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Transmission fluid temperature, modeled maximum reached A3E_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Transmission torque losses A3E_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Valve lift system, result of last switch, intake A3E_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Valve lift system, valve lift, exhaust A3E_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Valve lift system, valve lift, intake A3E_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Valve timing, the difference between the, actual and the set angle A3E_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Variable valve timing, intake, bank 1, regulation A3E_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Variable valve timing, intake, bank 1, switch on A3E_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Washer nozzle heater active A3E_MQB_HTR_NOZZLEConfirmed

  • Service 22DID 1945
  • Module70E → 778
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Wear index A3E_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2014 to 2016, 2018, 2020 to 2026. Not supported for 2017.

Wear index %, 0=new engine A3E_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

DPF

Service regeneration status A3E_PQ35_SRV_REGEN_STATConfirmed

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017. Supported for 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2017. Supported for 2018.

Fluids

Oil level, critical A3E_OIL_CRITConfirmed

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x2328 = 9000 → 90002500 = 3.6 cm

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Fuel

Activation of fuel pump electronics A3E_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Counter of fuel entry in oil A3E_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Error counter bad fuel A3E_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Fuel consumption A3E_FUEL_CONSConfirmed

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Fuel consumption - actual drive cycle A3E_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel consumption per driving cycle A3E_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel flow A3E_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel high pressure, actual value A3E_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Fuel high pressure, control deviation A3E_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Fuel high pressure, specified value A3E_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Fuel injector time deviation, cylinder 1 A3E_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel injector time deviation, cylinder 2 A3E_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel injector time deviation, cylinder 2 A3E_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel injector time deviation, cylinder 3 A3E_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel injector time deviation, cylinder 4 A3E_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel level A3E_FLI_7E0

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Fuel level input % A3E_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Fuel level input, v1 A3E_FUEL_LEVEL_INPUT_V1Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x01F4 = 500 → 500100 = 5 L

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Fuel low pressure, actual value A3E_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Fuel low pressure, specified value A3E_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Fuel mass request, integral controller A3E_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel mass request, proportional controller A3E_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fuel metering valve A3E_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Fuel mix correction coefficient A3E_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Fuel part from EVAP system A3E_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Fuel pressure, low actual A3E_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Fuel pump adaptation A3E_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Fuel pump specified value A3E_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Fuel pump, commanded duty A3E_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Fuel rate A3E_FUEL_RATE

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel rate difference, injector/sensor A3E_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel tank fill level A3E_FUEL_TANK_FILL_LEVEL

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 2014 to 2018, 2020 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2018.

Fuel temperature A3E_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Fuel temperature A3E_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Fuel temperature A3E_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

High fuel pressure, actual A3E_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

High fuel pressure, actual value A3E_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

High fuel pressure, commanded A3E_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

High fuel pressure, regulation error A3E_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

High fuel pressure, target A3E_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim at idle A3E_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim at idle A3E_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim bank 1 A3E_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim direct injection at load A3E_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Long term fuel trim port injection at load A3E_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Low fuel pressure, actual A3E_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Low fuel pressure, commanded A3E_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2014 to 2018, 2020 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual A3E_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum A3E_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Short term fuel trim bank 1 A3E_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

GPS

Satellites, tracked A3E_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2014 to 2017, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x07 = 7 → 7

Confirmed for 2018. In testing for 2014 to 2016, 2020 to 2026. Not supported for 2017.

Satellites, visible A3E_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2014 to 2017, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2018. In testing for 2014 to 2016, 2020 to 2026. Not supported for 2017.

Movement

Acceleration A3E_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Acceleration A3E_ACCEL_7E0

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Acceleration A3E_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Acceleration or deceleration mode A3E_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal position A3E_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal position A3E_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal position 1 A3E_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal position 2 A3E_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Accelerator pedal sensor 1 A3E_PQ35_ACCEL_PED_1Confirmed

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

0x0000 = 0 → 05 = 0 mV

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Accelerator pedal torque limit A3E_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Aux. hydraulic pump RPM A3E_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Camshaft speed A3E_CAM_SPD

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Camshaft speed A3E_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Compressor speed A3E_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Crankshaft speed A3E_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Crankshaft speed, RPM A3E_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Engine RPM A3E_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Engine RPM at idle required A3E_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Front left wheel speed A3E_TIRE_FL_SPD_V3

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016, 2020 to 2026. Not supported for 2017 to 2018.

Front right wheel speed A3E_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Idle speed specified rpm A3E_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Injection speed injector 0 A3E_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Injection speed injector 1 A3E_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Injection speed injector 2 A3E_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Injection speed injector 3 A3E_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Input shaft speed 1 A3E_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Input shaft speed 2 A3E_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Lateral acceleration A3E_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Longitudinal acceleration A3E_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Longitudinal acceleration, raw A3E_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm, all cylinders A3E_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm:, cylinder 1 A3E_MIS_PER_1000_RPM_1

  • Service 22DID 1484
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm:, cylinder 3 A3E_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm:, cylinder 4 A3E_MIS_PER_1000_RPM_4

  • Service 22DID 1485
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm:, cylinder 5 A3E_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires per 1000 rpm:, cylinder 6 A3E_MIS_PER_1000_RPM_6

  • Service 22DID 1487
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires/1000 rpm, cylinder 1 A3E_MISFIRES_1000_RPM_C1

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires/1000 rpm, cylinder 2 A3E_MISFIRES_1000_RPM_C2

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires/1000 rpm, cylinder 3 A3E_MISFIRES_1000_RPM_C3

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Misfires/1000 rpm, cylinder 4 A3E_MISFIRES_1000_RPM_C4

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Mixture adaptation factor at idle speed A3E_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Rear left wheel speed A3E_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Rear right wheel speed A3E_TIRE_RR_SPD_V3

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016, 2020 to 2026. Not supported for 2017 to 2018.

Reducing agent pump, differential speed calculated A3E_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2014 to 2018, 2020 to 2026.

Specified idle RPM A3E_MQB_DQ250_SPECIFIED_IDLE_RPMConfirmed

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Speed ​​output A3E_MQB_DQ250_SPD_OUTPUTConfirmed

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission input shaft speed A3E_PQ35_TRANS_IN_SPDConfirmed

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x0D4E = 3406 → 34062 = 1,703 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission input speed A3E_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380AConfirmed

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission output speed A3E_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380BConfirmed

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Vehicle lateral acceleration, raw value A3E_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2014 to 2018, 2020 to 2026.

Vehicle speed A3E_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Vehicle speed A3E_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017. Supported for 2018.

Vehicle speed ESP A3E_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Vehicle speed from transmission A3E_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSIONConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Vehicle speed, HR A3E_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Yaw acceleration, raw value A3E_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2014 to 2018, 2020 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2017. Supported for 2018.

Tires

Entire energy throughput A3E_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 2014 to 2018, 2020 to 2026.

Front left flat tire indicator A3E_TPMS_FR_L_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFE = 254 → 254

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front left tire pressure diffusion indicator A3E_TPMS_FR_L_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front left wheel speed A3E_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Front right flat tire indicator A3E_TPMS_FR_R_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFE = 254 → 254

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front right tire pressure diffusion indicator A3E_TPMS_FR_R_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Front right wheel speed A3E_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Rear left flat tire indicator A3E_TPMS_RR_L_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFE = 254 → 254

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rear left tire pressure diffusion indicator A3E_TPMS_RR_L_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rear left wheel speed A3E_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Rear right flat tire indicator A3E_TPMS_RR_R_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFE = 254 → 254

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rear right tire pressure diffusion indicator A3E_TPMS_RR_R_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Rear right wheel speed A3E_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2014 to 2018, 2020 to 2026.

Steering wheel angle A3E_MQB_SWAConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8+0.06
Range
-4095.94 to 4095.935 °
Unit
°

0x0000 = 0 → 08+0.06 = 0.06 °

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Steering wheel angle A3E_MQB_SWA_ALTConfirmed

  • Service 22DID 1804
  • Module713 → 77D
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.562 °
Unit
°

0xFEC1 = -319 → -319×0.4375 = -139.5625 °

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Steering wheel temperature A3E_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Steering wheel torque sensor 1 A3E_STEER_WHL_TQ_SENS_1

  • Service 22DID 1805
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Steering wheel torque sensor 2 A3E_STEER_WHL_TQ_SENS_2

  • Service 22DID 1806
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2014 to 2018, 2020 to 2026.

Tire pressure monitoring available A3E_TPMS_AVAILConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission

Actual position of gear positioner a A3E_MQB_DQ250_ACUTAL_POS_GEAR_POSER_AConfirmed

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0304 = 772 → 772×10010000 = 7.72 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Actual position of gear positioner b A3E_MQB_DQ250_ACUTAL_POS_GEAR_POSER_BConfirmed

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0300 = 768 → 768×10010000 = 7.68 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Actual position of gear positioner c A3E_MQB_DQ250_ACUTAL_POS_GEAR_POSER_CConfirmed

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Actual position of gear positioner d A3E_MQB_DQ250_ACUTAL_POS_GEAR_POSER_DConfirmed

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0000 = 0 → 0×10010000 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Adaptation counter PF lockup clutch A3E_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, clutch a A3E_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, clutch b A3E_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, clutch c A3E_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, clutch d A3E_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, clutch e A3E_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, fast fill time, clutch a A3E_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, fast fill time, clutch b A3E_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, fast fill time, clutch c A3E_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, fast fill time, clutch d A3E_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, fast fill time, clutch e A3E_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation counter, torque converter lockup clutch A3E_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Adaptation fill time, torque converter lockup clutch A3E_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Adaptation inflation current PF lockup clutch A3E_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

All-wheel drive clutch blockage degree A3E_MQB_HAL_CLUTCH_BLOCKConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 15 of the reply.

Formula
val×8
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0×8 = 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

All-wheel drive clutch fully open A3E_MQB_HAL_CLUTCH_OPENConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 actual pressure A3E_PQ35_CLUTCH_1_ACTUAL_PConfirmed

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0002 = 2 → 2100 = 0.02 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENTConfirmed

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 0 position A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POSConfirmed

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x02A1 = 673 → 673100 = 6.73 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 1 moment A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENTConfirmed

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x07D0 = 2000 → 200020 = 100 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 1 position A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POSConfirmed

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0524 = 1316 → 1316100 = 13.16 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 2 moment A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENTConfirmed

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x1F40 = 8000 → 800020 = 400 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 2 position A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POSConfirmed

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0C5D = 3165 → 3165100 = 31.65 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 3 moment A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENTConfirmed

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x2710 = 10000 → 1000020 = 500 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 adaptation basic characteristic point 3 position A3E_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POSConfirmed

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0FA0 = 4000 → 4000100 = 40 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 characteristic curve shift A3E_PQ35_CLUTCH_1_CHAR_CURVE_SHIFTConfirmed

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

0x0000 = 0 → 0×9.810000 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 commanded pressure A3E_PQ35_CLUTCH_1_CMD_PConfirmed

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 failed adaptations counter A3E_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 friction value correction factor A3E_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTORConfirmed

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 lower adaptation point A3E_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Clutch 1 nominal pressure A3E_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Clutch 1 protection function engaged quantity A3E_PQ35_CLUTCH_1_PROT_ENGAGED_QTYConfirmed

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000005 = 5 → 5

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 successful adaptations counter A3E_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1C07 = 7175 → 7,175

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 upper adaptation point A3E_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Clutch 1 valve current: actual A3E_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUALConfirmed

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 valve current: specified A3E_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 actual pressure A3E_PQ35_CLUTCH_2_ACTUAL_PConfirmed

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0302 = 770 → 770100 = 7.7 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 actual torque A3E_MQB_TCM_CLUTCH_2_ACTUAL_TORQUEConfirmed

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 0 moment A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENTConfirmed

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 0 position A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POSConfirmed

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x02B4 = 692 → 692100 = 6.92 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 1 moment A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENTConfirmed

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x07D0 = 2000 → 200020 = 100 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 1 position A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POSConfirmed

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x054E = 1358 → 1358100 = 13.58 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 2 moment A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENTConfirmed

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x1F40 = 8000 → 800020 = 400 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 2 position A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POSConfirmed

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0D0B = 3339 → 3339100 = 33.39 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 3 moment A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENTConfirmed

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x2710 = 10000 → 1000020 = 500 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation basic characteristic point 3 position A3E_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POSConfirmed

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0FA0 = 4000 → 4000100 = 40 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation end position closed A3E_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSEDConfirmed

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x05DC = 1500 → 1500100 = 15 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 adaptation end position opened A3E_PQ35_CLUTCH_2_ADAPT_END_POS_OPENEDConfirmed

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 characteristic curve shift A3E_PQ35_CLUTCH_2_CHAR_CURVE_SHIFTConfirmed

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

0x0000 = 0 → 0×9.810000 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 commanded pressure A3E_PQ35_CLUTCH_2_CMD_PConfirmed

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 failed adaptations counter A3E_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 friction value correction factor A3E_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTORConfirmed

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

0x0004 = 4 → 4×0.09766 = 0.39064 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 lower adaptation point A3E_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Clutch 2 protection function engaged quantity A3E_PQ35_CLUTCH_2_PROT_ENGAGED_QTYConfirmed

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000011 = 17 → 17

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 successful adaptations counter A3E_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1141 = 4417 → 4,417

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 upper adaptation point A3E_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Clutch 2 valve current: actual A3E_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUALConfirmed

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 2 valve current: specified A3E_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch kiss point rapid adaptation remaining A3E_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAININGConfirmed

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch overheating, clutch A3E_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Clutch temperature A3E_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Current gear A3E_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Current gear A3E_MQB_TCM_I_GEAR_DQ200Confirmed

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

0x00 = 0 → 0−2 = -2

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Current N371 pressure control valve 6 lock-up clutch A3E_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2014 to 2018, 2020 to 2026.

Driving strategy mountain factor A3E_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTORConfirmed

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Driving strategy sport factor A3E_PQ35_DRIVING_STRATEGY_SPORT_FACTORConfirmed

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×1700255 = 0 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Dynamic shift program A3E_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for oxygen shift, cylinder 1 A3E_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for oxygen shift, cylinder 2 A3E_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for oxygen shift, cylinder 3 A3E_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Early ignition counter for oxygen shift, cylinder 4 A3E_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Engine specified torque during transmission intervention A3E_ENG_SPEC_TQ_DURINGConfirmed

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x005A = 90 → 90 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Fast fill time, clutch a A3E_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Fast fill time, clutch b A3E_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Fast fill time, clutch c A3E_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Fast fill time, clutch d A3E_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Fast fill time, clutch e A3E_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Fill pressure, clutch a A3E_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fill pressure, clutch b A3E_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fill pressure, clutch c A3E_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fill pressure, clutch d A3E_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Fill pressure, clutch e A3E_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2014 to 2018, 2020 to 2026.

Gear A3E_GEAR_V2Confirmed

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G1 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1Confirmed

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0300 = 768 → 768100 = 7.68 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G2 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2Confirmed

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFCB5 = -843 → -843100 = -8.43 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G3 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3Confirmed

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFCAF = -849 → -849100 = -8.49 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G4 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4Confirmed

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0300 = 768 → 768100 = 7.68 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G5 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5Confirmed

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0301 = 769 → 769100 = 7.69 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G6 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6Confirmed

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0302 = 770 → 770100 = 7.7 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position G7 A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7Confirmed

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation engaged position GR A3E_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GRConfirmed

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFCC2 = -830 → -830100 = -8.3 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G1 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1Confirmed

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x00DD = 221 → 221100 = 2.21 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G2 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2Confirmed

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFF00 = -256 → -256100 = -2.56 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G3 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3Confirmed

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFF18 = -232 → -232100 = -2.32 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G4 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4Confirmed

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x00E5 = 229 → 229100 = 2.29 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G5 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5Confirmed

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x00B1 = 177 → 177100 = 1.77 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G6 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6Confirmed

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x00E3 = 227 → 227100 = 2.27 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position G7 A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7Confirmed

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear actuator adaptation synchronization position reverse A3E_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GRConfirmed

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFF01 = -255 → -255100 = -2.55 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear selector a adaptation neutral position A3E_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFFE4 = -28 → -28100 = -0.28 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear selector b adaptation neutral position A3E_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFFED = -19 → -19100 = -0.19 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear selector c adaptation neutral position A3E_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Gear selector d adaptation neutral position A3E_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xFFF3 = -13 → -13100 = -0.13 mm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Input shaft 1 A3E_MQB_INPUT_SHAFT_1Confirmed

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Input shaft 2 A3E_MQB_INPUT_SHAFT_2Confirmed

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Launch control counter, clutch 1 A3E_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Load shift flaps, actual value A3E_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Load shift flaps, specified value A3E_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Mileage of oxidation catalytic converter A3E_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Mileage of SCR catalytic converter A3E_MILEAGE_SCR

  • Service 22DID 519E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Nominal pressure clutch 2 A3E_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Output shaft 1 A3E_MQB_OUTPUT_SHAFT_1Confirmed

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Output shaft 2 A3E_MQB_OUTPUT_SHAFT_2Confirmed

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Powertrain overall gear ratio A3E_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Pressure_clutch_1 A3E_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Pressure_clutch_2 A3E_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2014 to 2018, 2020 to 2026.

Road resistance A3E_PQ35_ROAD_RESISTANCEConfirmed

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

0x45 = 69 → 69×24.9100−31.6 = -14.419 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Selected gear A3E_SELECTED_GEAR

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Shift process, selected gear A3E_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Shift process, target gear A3E_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Specified torque clutch 1 A3E_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1Confirmed

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 0×5100 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Specified torque clutch 1 - data A3E_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Specified torque clutch 2 A3E_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2Confirmed

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 0×5100 = 0 N·m

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Specified torque clutch 2 - data A3E_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Time since shift A3E_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2014 to 2018, 2020 to 2026.

Torque converter amplification A3E_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Torque loss adaptation, A/C compressor + gear engaged A3E_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Torque loss adaptation, gear engaged A3E_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2014 to 2018, 2020 to 2026.

Transmission coolant valve, open A3E_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Transmission fluid temperature 2 A3E_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2014 to 2018, 2020 to 2026.

Transmission gear ratio A3E_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2014 to 2018, 2020 to 2026.

Transmission part 1 pressure actual A3E_MQB_TCM_TRANSMISSION_PART_1_P_ACTUALConfirmed

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 1 pressure commanded A3E_MQB_TCM_TRANSMISSION_PART_1_P_CMDConfirmed

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 1 valve current actual A3E_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUALConfirmed

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x001E = 30 → 3010 = 3 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 1 valve current commanded A3E_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMDConfirmed

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 2 pressure actual A3E_MQB_TCM_TRANSMISSION_PART_2_P_ACTUALConfirmed

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 2 pressure commanded A3E_MQB_TCM_TRANSMISSION_PART_2_P_CMDConfirmed

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 2 valve current actual A3E_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUALConfirmed

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x0910 = 2320 → 232010 = 232 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Transmission part 2 valve current commanded A3E_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMDConfirmed

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Working hours A3E_PQ35_WORKING_HOURSConfirmed

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

0x30BF2E00 = 817835520 → 817835520×2360000 = 4,543.530667

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 A3E_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 1 temperature time in range 2 A3E_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 1 temperature time in range 3 A3E_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 2 temperature time in range 0 A3E_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 2 temperature time in range 1 A3E_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 2 temperature time in range 2 A3E_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Analysis, clutch 2 temperature time in range 3 A3E_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Average consumption, category 0 A3E_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 1 A3E_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 2 A3E_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 3 A3E_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 4 A3E_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 5 A3E_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008C = 140 → 14010 = 14 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Average consumption, category 6 A3E_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00A0 = 160 → 16010 = 16 kWh

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Clutch 1 adaptation kiss point part 1 odometer reading A3E_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

0x2B07 = 11015 → 11015×10 = 110,150 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Clutch 1 temperature time in range 0 A3E_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2014 to 2018, 2020 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading A3E_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

0x2B02 = 11010 → 11010×10 = 110,100 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Counter steer support, odometer, last activated A3E_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACTConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Distance to detected pedestrian A3E_DIST_DETECTED

  • Service 22DID F41B
  • Module74F → 7B9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 m
Unit
m

In testing for 2014 to 2018, 2020 to 2026.

Drive cycles counter A3E_MQB_TCM_DRIVE_CYCLES_COUNTERConfirmed

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x081C = 2076 → 2,076

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Driving time ecological A3E_MQB_TCM_DRIVING_TIME_ECOLOGICALConfirmed

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x51 = 81 → 81 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Driving time manual A3E_MQB_TCM_DRIVING_TIME_MANUALConfirmed

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x07 = 7 → 7 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Driving time sporty A3E_MQB_TCM_DRIVING_TIME_SPORTYConfirmed

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x0C = 12 → 12 %

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Ignition cycles A3E_MQB_TCM_IGNITION_CYCLESConfirmed

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Mixture variation in adapted part load range 1 A3E_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2018, 2020 to 2026.

Odometer A3E_MQB_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777175 km
Unit
km

In testing for 2014 to 2016, 2020 to 2026. Supported for 2017 to 2018.

Odometer A3E_MQB_TCM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x53650B00 = 1399130880 → 139913088010 = 139,913,088 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Odometer A3E_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x0001268E = 75406 → 75,406 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Odometer A3E_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Odometer A3E_ODO_7E1

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Odometer #2 A3E_MQB_TCM_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x000B51A6 = 741798 → 74179810 = 74,179.8 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Odometer #3 A3E_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x01268E = 75406 → 75,406 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Odometer at oxidation catalytic converter replacement A3E_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Odometer at SCR catalytic converter replacement A3E_ODO_SCR_CATALYTIC

  • Service 22DID 4F41
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Odometer reading at fourth-to-last warning A3E_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARNConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0001194E = 72014 → 72,014 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading at last adaptation A3E_TPMS_ODO_RDG_AT_LAST_ADAPTConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00017F79 = 98169 → 98,169 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading at last warning A3E_TPMS_ODO_RDG_AT_LAST_WARNConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00017DFC = 97788 → 97,788 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading at next-to-last warning A3E_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARNConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x000172BE = 94910 → 94,910 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading at third-to-last warning A3E_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARNConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00015BDC = 89052 → 89,052 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading four adaptations ago A3E_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00013991 = 80273 → 80,273 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading three adaptations ago A3E_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00016119 = 90393 → 90,393 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer reading two adaptations ago A3E_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2014 to 2016, 2018, 2020 to 2026

Example reply from a 2017 Audi A3 e-tron.

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0001748D = 95373 → 95,373 km

Confirmed for 2017. In testing for 2014 to 2016, 2018, 2020 to 2026.

Odometer with ECU installed A3E_ODO_ECU_INSTALLED

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2014 to 2018, 2020 to 2026.

Odometer, high resolution A3E_ODO_HDConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

0x047CD249 = 75289161 → 752891611000 = 75,289.161 km

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Odometer, mileage, HR A3E_ODO_MILEAGE_HR

Pelican can show this parameter as the odometer.

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 1 A3E_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 2 A3E_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 3 A3E_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 4 A3E_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 5 A3E_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Operating time, temperature range 6 A3E_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2014 to 2018, 2020 to 2026.

Range remaining A3E_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2014 to 2016, 2020 to 2026

Example reply from a 2018 Audi A3 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x0131 = 305 → 305 mi

Confirmed for 2017 to 2018. In testing for 2014 to 2016, 2020 to 2026.

Remaining distance until reducing agent deficiency A3E_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 1 A3E_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 2 A3E_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 3 A3E_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 4 A3E_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 5 A3E_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 6 A3E_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 7 A3E_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Torque converter time in temperature range 8 A3E_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2014 to 2018, 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.