Audi Q8 e-tron

Parameters

The Audi Q8 e-tron has 902 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage Q8_E_TRON_TRON_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x20E5 = 8421 → 84211000+4 = 12.421 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

3V supply voltage Q8_E_TRON_CHRGR_3V_SUPPLYConfirmed

  • Service 22DID 15F7
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val100+3.1
Range
3.1 to 5.65 V
Unit
V

0x15 = 21 → 21100+3.1 = 3.31 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

12V battery adapted capacity Q8_AUX_BAT_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery aging by capacity Q8_AUX_BAT_AGE_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery aging by power Q8_AUX_BAT_AGE_POW

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery capacity Q8_E_TRON_TRON_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2018 to 2025.

12V battery current Q8_AUX_BAT_C

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery soc Q8_AUX_BAT_SOC

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery total charge Q8_AUX_BAT_CHRG_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery total discharge Q8_AUX_BAT_DSCH_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

12V battery voltage Q8_AUX_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

Battery acid stratification Q8_E_TRON_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2018 to 2025.

Battery charge level Q8_E_TRON_TRON_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x53 = 83 → 83 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery condition for display Q8_E_TRON_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2018 to 2025.

Battery current Q8_E_TRON_TRON_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483 A
Unit
A

0x00000000 = 0 → 01000 = 0 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery current filtered Q8_E_TRON_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2018 to 2025.

Battery internal resistance Q8_E_TRON_TRON_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x12 = 18 → 18×20100 = 3.6

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery internal resistance, raw Q8_E_TRON_TRON_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2018 to 2025.

Battery power reduction active Q8_E_TRON_BMS_PWR_REDUCE_ACTConfirmed

  • Service 22DID 1E0A
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery sensor temperature Q8_E_TRON_TRON_MQB_BAT_SEN_TConfirmed

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x43 = 67 → 67−40 = 27 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery temperature Q8_E_TRON_TRON_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery total charge Q8_BAT_TOT_CHG

  • Service 22DID 2A61
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

Battery total discharge Q8_BAT_TOT_DIS

  • Service 22DID 2A61
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

Battery voltage Q8_E_TRON_TRON_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x20E5 = 8421 → 84211000+4 = 12.421 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery voltage at rest Q8_E_TRON_TRON_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x24 = 36 → 3610+9 = 12.6 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell state of charge max, index Q8_E_TRON_BMS_CELL_SOC_MAX_IDXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell state of charge max, value Q8_E_TRON_BMS_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x26 = 38 → 38 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell state of charge min, index Q8_E_TRON_BMS_CELL_SOC_MIN_IDXConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell state of charge min, value Q8_E_TRON_BMS_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x25 = 37 → 37 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell voltage max, index Q8_E_TRON_BMS_CELL_V_MAX_IDXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell voltage max, value Q8_E_TRON_BMS_CELL_V_MAXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0E28 = 3624 → 36241000 = 3.624 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell voltage min, index Q8_E_TRON_BMS_CELL_V_MIN_IDXConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell voltage min, value Q8_E_TRON_BMS_CELL_V_MINConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0E23 = 3619 → 36191000 = 3.619 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cell voltage sum Q8_E_TRON_BMS_CELL_V_SUMConfirmed

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0F1E = 3870 → 387010 = 387 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Charge air pressure Q8_E_TRON_TRON_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Charger AC input current Q8_CHG_AC_I

  • Service 22DID 1DA8
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2018 to 2025.

Charger AC input current set point Q8_CHG_AC_I_SET

  • Service 22DID 15D3
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2018 to 2025.

Charger AC input voltage Q8_CHG_AC_V

  • Service 22DID 1DA9
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2018 to 2025.

Charger coolant temperature Q8_E_TRON_CHRGR_COOLANT_TConfirmed

  • Service 22DID 15E2
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x47 = 71 → 71−40 = 31 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Charger DC to DC coil temperature Q8_CHG_DCDC_COIL_T

  • Service 22DID 15DA
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2025.

Charger DC to DC gate driver voltage Q8_CHG_DCDC_GATE_V

  • Service 22DID 15DD
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2018 to 2025.

Charger DC to DC power line temperature Q8_CHG_DCDC_LINE_T

  • Service 22DID 15EC
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2025.

Charger output current Q8_E_TRON_CHG_HV_I

  • Service 22DID 4237
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2018 to 2025.

Charger output current set point Q8_E_TRON_CHG_HV_I_SET

  • Service 22DID 4238
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2018 to 2025.

Charger power factor coil temperature Q8_CHG_PFC_COIL_T

  • Service 22DID 15D9
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2025.

Charger power factor gate driver voltage Q8_CHG_PFC_GATE_V

  • Service 22DID 15DC
  • Module744 → 7AE
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2018 to 2025.

Charger temperature Q8_CHG_T

  • Service 22DID 15D8
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2025.

Charging duration total Q8_E_TRON_CHRGR_DUR_TOTALConfirmed

  • Service 22DID 15EE
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

0x00012D21 = 77089 → 77,089 min

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Control module voltage Q8_E_TRON_TRON_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2E4F = 11855 → 118551000 = 11.855 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2024.

Cooling pump power set point Q8_E_TRON_BMS_COOL_PUMP_PWR_SP

  • Service 22DID 192B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

Cycle energy transformation Q8_OBC_CYCLE_ENERGY

  • Service 22DID 103E
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kWh
Unit
kWh

In testing for 2018 to 2023, 2025. Not supported for 2024.

DC-DC converter, current Q8_E_TRON_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

DC-DC converter, low voltage Q8_E_TRON_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x7D = 125 → 12510 = 12.5 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

DC-DC converter, reserved current Q8_E_TRON_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Electric motor battery energy Q8_HV_EM_HVBAT_ENERGY_INFORMATION

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2018 to 2023, 2025. Not supported for 2024.

Emergency call battery critical status Q8_ECALL_BAT_CRIT

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

Emergency call battery level Q8_ECALL_BAT_LVL

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

Energy turnover total Q8_E_TRON_CHRGR_E_TOTALConfirmed

  • Service 22DID 15EF
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

0x0001D3AA = 119722 → 119,722 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Estimated reserve range Q8_E_TRON_RANGE_EST_CANConfirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00AB = 171 → 171 km

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Generator target voltage Q8_E_TRON_TRON_MQB_GEN_TRG_VConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
10.6 to 36.1 V
Unit
V

0x00 = 0 → 010+10.6 = 10.6 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Generator voltage, actual Q8_E_TRON_TRON_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2018 to 2025.

High-voltage battery charge Q8_E_TRON_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x4C = 76 → 762 = 38 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery cell 1 voltage Q8_E_TRON_HVBAT_CELL_1_V

  • Service 22DID 1E40
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 2 voltage Q8_E_TRON_HVBAT_CELL_2_V

  • Service 22DID 1E41
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 3 voltage Q8_E_TRON_HVBAT_CELL_3_V

  • Service 22DID 1E42
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 4 voltage Q8_E_TRON_HVBAT_CELL_4_V

  • Service 22DID 1E43
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 5 voltage Q8_E_TRON_HVBAT_CELL_5_V

  • Service 22DID 1E44
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 6 voltage Q8_E_TRON_HVBAT_CELL_6_V

  • Service 22DID 1E45
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 7 voltage Q8_E_TRON_HVBAT_CELL_7_V

  • Service 22DID 1E46
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 8 voltage Q8_E_TRON_HVBAT_CELL_8_V

  • Service 22DID 1E47
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 9 voltage Q8_E_TRON_HVBAT_CELL_9_V

  • Service 22DID 1E48
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 10 voltage Q8_E_TRON_HVBAT_CELL_10_V

  • Service 22DID 1E49
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 11 voltage Q8_E_TRON_HVBAT_CELL_11_V

  • Service 22DID 1E4A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 12 voltage Q8_E_TRON_HVBAT_CELL_12_V

  • Service 22DID 1E4B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 13 voltage Q8_E_TRON_HVBAT_CELL_13_V

  • Service 22DID 1E4C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 14 voltage Q8_E_TRON_HVBAT_CELL_14_V

  • Service 22DID 1E4D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 15 voltage Q8_E_TRON_HVBAT_CELL_15_V

  • Service 22DID 1E4E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 16 voltage Q8_E_TRON_HVBAT_CELL_16_V

  • Service 22DID 1E4F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 17 voltage Q8_E_TRON_HVBAT_CELL_17_V

  • Service 22DID 1E50
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 18 voltage Q8_E_TRON_HVBAT_CELL_18_V

  • Service 22DID 1E51
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 19 voltage Q8_E_TRON_HVBAT_CELL_19_V

  • Service 22DID 1E52
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 20 voltage Q8_E_TRON_HVBAT_CELL_20_V

  • Service 22DID 1E53
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 21 voltage Q8_E_TRON_HVBAT_CELL_21_V

  • Service 22DID 1E54
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 22 voltage Q8_E_TRON_HVBAT_CELL_22_V

  • Service 22DID 1E55
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 23 voltage Q8_E_TRON_HVBAT_CELL_23_V

  • Service 22DID 1E56
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 24 voltage Q8_E_TRON_HVBAT_CELL_24_V

  • Service 22DID 1E57
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 25 voltage Q8_E_TRON_HVBAT_CELL_25_V

  • Service 22DID 1E58
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 26 voltage Q8_E_TRON_HVBAT_CELL_26_V

  • Service 22DID 1E59
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 27 voltage Q8_E_TRON_HVBAT_CELL_27_V

  • Service 22DID 1E5A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 28 voltage Q8_E_TRON_HVBAT_CELL_28_V

  • Service 22DID 1E5B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 29 voltage Q8_E_TRON_HVBAT_CELL_29_V

  • Service 22DID 1E5C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 30 voltage Q8_E_TRON_HVBAT_CELL_30_V

  • Service 22DID 1E5D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 31 voltage Q8_E_TRON_HVBAT_CELL_31_V

  • Service 22DID 1E5E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 32 voltage Q8_E_TRON_HVBAT_CELL_32_V

  • Service 22DID 1E5F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 33 voltage Q8_E_TRON_HVBAT_CELL_33_V

  • Service 22DID 1E60
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 34 voltage Q8_E_TRON_HVBAT_CELL_34_V

  • Service 22DID 1E61
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 35 voltage Q8_E_TRON_HVBAT_CELL_35_V

  • Service 22DID 1E62
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 36 voltage Q8_E_TRON_HVBAT_CELL_36_V

  • Service 22DID 1E63
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 37 voltage Q8_E_TRON_HVBAT_CELL_37_V

  • Service 22DID 1E64
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 38 voltage Q8_E_TRON_HVBAT_CELL_38_V

  • Service 22DID 1E65
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 39 voltage Q8_E_TRON_HVBAT_CELL_39_V

  • Service 22DID 1E66
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 40 voltage Q8_E_TRON_HVBAT_CELL_40_V

  • Service 22DID 1E67
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 41 voltage Q8_E_TRON_HVBAT_CELL_41_V

  • Service 22DID 1E68
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 42 voltage Q8_E_TRON_HVBAT_CELL_42_V

  • Service 22DID 1E69
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 43 voltage Q8_E_TRON_HVBAT_CELL_43_V

  • Service 22DID 1E6A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 44 voltage Q8_E_TRON_HVBAT_CELL_44_V

  • Service 22DID 1E6B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 45 voltage Q8_E_TRON_HVBAT_CELL_45_V

  • Service 22DID 1E6C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 46 voltage Q8_E_TRON_HVBAT_CELL_46_V

  • Service 22DID 1E6D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 47 voltage Q8_E_TRON_HVBAT_CELL_47_V

  • Service 22DID 1E6E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 48 voltage Q8_E_TRON_HVBAT_CELL_48_V

  • Service 22DID 1E6F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 49 voltage Q8_E_TRON_HVBAT_CELL_49_V

  • Service 22DID 1E70
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 50 voltage Q8_E_TRON_HVBAT_CELL_50_V

  • Service 22DID 1E71
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 51 voltage Q8_E_TRON_HVBAT_CELL_51_V

  • Service 22DID 1E72
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 52 voltage Q8_E_TRON_HVBAT_CELL_52_V

  • Service 22DID 1E73
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 53 voltage Q8_E_TRON_HVBAT_CELL_53_V

  • Service 22DID 1E74
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 54 voltage Q8_E_TRON_HVBAT_CELL_54_V

  • Service 22DID 1E75
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 55 voltage Q8_E_TRON_HVBAT_CELL_55_V

  • Service 22DID 1E76
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 56 voltage Q8_E_TRON_HVBAT_CELL_56_V

  • Service 22DID 1E77
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 57 voltage Q8_E_TRON_HVBAT_CELL_57_V

  • Service 22DID 1E78
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 58 voltage Q8_E_TRON_HVBAT_CELL_58_V

  • Service 22DID 1E79
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 59 voltage Q8_E_TRON_HVBAT_CELL_59_V

  • Service 22DID 1E7A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 60 voltage Q8_E_TRON_HVBAT_CELL_60_V

  • Service 22DID 1E7B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 61 voltage Q8_E_TRON_HVBAT_CELL_61_V

  • Service 22DID 1E7C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 62 voltage Q8_E_TRON_HVBAT_CELL_62_V

  • Service 22DID 1E7D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 63 voltage Q8_E_TRON_HVBAT_CELL_63_V

  • Service 22DID 1E7E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 64 voltage Q8_E_TRON_HVBAT_CELL_64_V

  • Service 22DID 1E7F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 65 voltage Q8_E_TRON_HVBAT_CELL_65_V

  • Service 22DID 1E80
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 66 voltage Q8_E_TRON_HVBAT_CELL_66_V

  • Service 22DID 1E81
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 67 voltage Q8_E_TRON_HVBAT_CELL_67_V

  • Service 22DID 1E82
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 68 voltage Q8_E_TRON_HVBAT_CELL_68_V

  • Service 22DID 1E83
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 69 voltage Q8_E_TRON_HVBAT_CELL_69_V

  • Service 22DID 1E84
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 70 voltage Q8_E_TRON_HVBAT_CELL_70_V

  • Service 22DID 1E85
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 71 voltage Q8_E_TRON_HVBAT_CELL_71_V

  • Service 22DID 1E86
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 72 voltage Q8_E_TRON_HVBAT_CELL_72_V

  • Service 22DID 1E87
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 73 voltage Q8_E_TRON_HVBAT_CELL_73_V

  • Service 22DID 1E88
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 74 voltage Q8_E_TRON_HVBAT_CELL_74_V

  • Service 22DID 1E89
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 75 voltage Q8_E_TRON_HVBAT_CELL_75_V

  • Service 22DID 1E8A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 76 voltage Q8_E_TRON_HVBAT_CELL_76_V

  • Service 22DID 1E8B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 77 voltage Q8_E_TRON_HVBAT_CELL_77_V

  • Service 22DID 1E8C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 78 voltage Q8_E_TRON_HVBAT_CELL_78_V

  • Service 22DID 1E8D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 79 voltage Q8_E_TRON_HVBAT_CELL_79_V

  • Service 22DID 1E8E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 80 voltage Q8_E_TRON_HVBAT_CELL_80_V

  • Service 22DID 1E8F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 81 voltage Q8_E_TRON_HVBAT_CELL_81_V

  • Service 22DID 1E90
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 82 voltage Q8_E_TRON_HVBAT_CELL_82_V

  • Service 22DID 1E91
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 83 voltage Q8_E_TRON_HVBAT_CELL_83_V

  • Service 22DID 1E92
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 84 voltage Q8_E_TRON_HVBAT_CELL_84_V

  • Service 22DID 1E93
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 85 voltage Q8_E_TRON_HVBAT_CELL_85_V

  • Service 22DID 1E94
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 86 voltage Q8_E_TRON_HVBAT_CELL_86_V

  • Service 22DID 1E95
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 87 voltage Q8_E_TRON_HVBAT_CELL_87_V

  • Service 22DID 1E96
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 88 voltage Q8_E_TRON_HVBAT_CELL_88_V

  • Service 22DID 1E97
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 89 voltage Q8_E_TRON_HVBAT_CELL_89_V

  • Service 22DID 1E98
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 90 voltage Q8_E_TRON_HVBAT_CELL_90_V

  • Service 22DID 1E99
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 91 voltage Q8_E_TRON_HVBAT_CELL_91_V

  • Service 22DID 1E9A
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 92 voltage Q8_E_TRON_HVBAT_CELL_92_V

  • Service 22DID 1E9B
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 93 voltage Q8_E_TRON_HVBAT_CELL_93_V

  • Service 22DID 1E9C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 94 voltage Q8_E_TRON_HVBAT_CELL_94_V

  • Service 22DID 1E9D
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 95 voltage Q8_E_TRON_HVBAT_CELL_95_V

  • Service 22DID 1E9E
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 96 voltage Q8_E_TRON_HVBAT_CELL_96_V

  • Service 22DID 1E9F
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 97 voltage Q8_E_TRON_HVBAT_CELL_97_V

  • Service 22DID 1EA0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 98 voltage Q8_E_TRON_HVBAT_CELL_98_V

  • Service 22DID 1EA1
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 99 voltage Q8_E_TRON_HVBAT_CELL_99_V

  • Service 22DID 1EA2
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 100 voltage Q8_E_TRON_HVBAT_CELL_100_V

  • Service 22DID 1EA3
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 101 voltage Q8_E_TRON_HVBAT_CELL_101_V

  • Service 22DID 1EA4
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell 102 voltage Q8_E_TRON_HVBAT_CELL_102_V

  • Service 22DID 1EA5
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2018 to 2025.

HV battery cell voltage sum Q8_E_TRON_HVBAT_CELL_SUM_V

  • Service 22DID 1E3C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val4096
Range
0 to 4095.999 V
Unit
V

In testing for 2018 to 2025.

HV battery charge, displayed Q8_E_TRON_HVBAT_SOC_DISP

HV battery charge displayed on the dashboard

Pelican can show this parameter as the state of charge.

  • Service 22DID 08D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery coolant pump control value Q8_E_TRON_BMS_COOL_PUMP_CTL

  • Service 22DID 80EC
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery current Q8_E_TRON_BMS_I

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1802
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2.56−1500
Range
-1500 to 166269 A
Unit
A

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery current Q8_E_TRON_HVBAT_CURRENTConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2018 to 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−511
Range
-200 to 200 A
Unit
A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery energy Q8_E_TRON_HVBAT_KWHConfirmed

Energy stored in the high voltage battery

Pelican can show this parameter as the traction battery capacity.

  • Service 22DID 4965
  • Module744 → 7AE
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kWh
Unit
kWh

0x02B2 = 690 → 69020 = 34.5 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery energy content Q8_E_TRON_HVBAT_E_CONTENTConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638 kWh
Unit
kWh

0x0006 = 6 → 6×251000 = 0.15 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery health Q8_E_TRON_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 6524 %
Unit
%

0x3A0F = 14863 → 14863×0.127−1798.574 = 89.027 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery isolation resistance, negative Q8_E_TRON_HVBAT_ISO_NEG

  • Service 22DID 1E1A
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2018 to 2025.

HV battery isolation resistance, positive Q8_E_TRON_HVBAT_ISO_POS

  • Service 22DID 1E18
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2018 to 2025.

HV battery negative voltage before the contactors Q8_HVBAT_NEG_V_PRE

  • Service 22DID 1E35
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 V
Unit
V

In testing for 2018 to 2025.

HV battery positive voltage after the charging contactors Q8_HVBAT_POS_V_POST

  • Service 22DID 1E39
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 V
Unit
V

In testing for 2018 to 2025.

HV battery positive voltage before the contactors Q8_HVBAT_POS_V_PRE

  • Service 22DID 1E36
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2018 to 2025.

HV battery state of charge Q8_E_TRON_BMS_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x25 = 37 → 37 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery state of charge display Q8_E_TRON_CHRGR_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 1DD0
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x47 = 71 → 712 = 35.5 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery state of charge, hd Q8_E_TRON_BMS_SOC_HIRESConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID F45B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x62 = 98 → 98×100255 = 38.431373 %

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery temperature Q8_HVBAT_T

  • Service 22DID 2A0B
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 1 Q8_HVBAT_T_1

  • Service 22DID 1EAE
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 2 Q8_HVBAT_T_2

  • Service 22DID 1EAF
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 3 Q8_HVBAT_T_3

  • Service 22DID 1EB0
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 4 Q8_HVBAT_T_4

  • Service 22DID 1EB1
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 5 Q8_HVBAT_T_5

  • Service 22DID 1EB2
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 6 Q8_HVBAT_T_6

  • Service 22DID 1EB3
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 7 Q8_HVBAT_T_7

  • Service 22DID 1EB4
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 8 Q8_HVBAT_T_8

  • Service 22DID 1EB5
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 9 Q8_HVBAT_T_9

  • Service 22DID 1EB6
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 10 Q8_HVBAT_T_10

  • Service 22DID 1EB7
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 11 Q8_HVBAT_T_11

  • Service 22DID 1EB8
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 12 Q8_HVBAT_T_12

  • Service 22DID 1EB9
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 13 Q8_HVBAT_T_13

  • Service 22DID 1EBA
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 15 Q8_HVBAT_T_15

  • Service 22DID 1EBC
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 16 Q8_HVBAT_T_16

  • Service 22DID 1EBD
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature sensor 17 Q8_HVBAT_T_17

  • Service 22DID 7425
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2018 to 2025.

HV battery temperature, average Q8_E_TRON_BMS_T_AVG

  • Service 22DID 1E10
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery temperature, maximum Q8_E_TRON_BMS_T_MAXConfirmed

  • Service 22DID 1E0E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

0x83 = 131 → 131−100 = 31 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery temperature, maximum, cell # Q8_E_TRON_BMS_T_MAX_CELLConfirmed

  • Service 22DID 1E0E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x26 = 38 → 38

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery temperature, minimum Q8_E_TRON_BMS_T_MINConfirmed

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

0x81 = 129 → 129−100 = 29 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery temperature, minimum, cell # Q8_E_TRON_BMS_T_MIN_CELLConfirmed

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x48 = 72 → 72

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV battery total ampere hours of charge Q8_HVBAT_TOT_AH_CHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery total ampere hours of discharge Q8_HVBAT_TOT_AH_DCHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val549.31642
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery total kilowatt hours of charge Q8_HVBAT_TOT_KWH_CHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500300 kWh
Unit
kWh

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery total kilowatt hours of discharge Q8_HVBAT_TOT_KWH_DCHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199 to 250199 kWh
Unit
kWh

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery voltage Q8_E_TRON_HVBAT_VOLT

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1801
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery voltage, measurement 2 Q8_HVBAT_V_180A

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 180A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2025.

HV battery voltage, measurement 3 Q8_HVBAT_V_180B

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 180B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2025.

HV battery voltage, measurement 4 Q8_HVBAT_V_1818

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 1818
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2025.

HV battery voltage, measurement 5 Q8_HVBAT_V_181B

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 181B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2025.

HV battery, max energy Q8_E_TRON_HVBAT_E_MAXConfirmed

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0221 = 545 → 545×50 = 27,250 W

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, commanded current Q8_E_TRON_CHRGR_BOOST_CMD_IConfirmed

  • Service 22DID 155A
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

0x0FFC = 4092 → 40924−512 = 511 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, commanded voltage Q8_E_TRON_CHRGR_BOOST_CMD_VConfirmed

  • Service 22DID 1559
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

0x0000 = 0 → 04 = 0 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, HV high side current Q8_E_TRON_CHRGR_BOOST_HI_IConfirmed

  • Service 22DID 1553
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

0x0800 = 2048 → 20484−512 = 0 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, HV high side voltage Q8_E_TRON_CHRGR_BOOST_HI_VConfirmed

  • Service 22DID 1554
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

0x0000 = 0 → 04 = 0 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, HV low side current Q8_E_TRON_CHRGR_BOOST_LO_IConfirmed

  • Service 22DID 1557
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

0x0000 = 0 → 04−512 = -512 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV booster, HV low side voltage Q8_E_TRON_CHRGR_BOOST_LO_VConfirmed

  • Service 22DID 1558
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

0x0800 = 2048 → 20484 = 512 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV charger output voltage Q8_E_TRON_CHRGR_V_OUTConfirmed

  • Service 22DID 1DA7
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

0x01 = 1 → 1 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

HV interlock detector voltage Q8_E_TRON_HV_INTERLOCK_DET_V

  • Service 22DID 74B9
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2018 to 2025.

HV interlock source current Q8_E_TRON_HV_INTERLOCK_SRC_I

  • Service 22DID 74BC
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 mA
Unit
mA

In testing for 2018 to 2025.

HV interlock source voltage Q8_E_TRON_HV_INTERLOCK_SRC_V

  • Service 22DID 74BA
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2018 to 2025.

HV system isolation resistance, negative Q8_E_TRON_HV_ISO_NEG_SYS

  • Service 22DID 1E19
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2018 to 2025.

HV system isolation resistance, positive Q8_E_TRON_HV_ISO_POS_SYS

  • Service 22DID 1E17
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2018 to 2025.

Maximum charge current Q8_E_TRON_MAX_CHA_CUR_2Confirmed

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0x0316 = 790 → 79010 = 79 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum charge power Q8_E_TRON_CHRGR_CHG_PWR_MAXConfirmed

  • Service 22DID 1DD3
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum charge voltage Q8_E_TRON_BMS_V_CHG_MAXConfirmed

  • Service 22DID 5171
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x11B2 = 4530 → 453010 = 453 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum charging power Q8_E_TRON_CHRGR_PWR_MAXConfirmed

  • Service 22DID 15D5
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0000 = 0 → 0 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum discharge current Q8_E_TRON_MAX_DCHA_CUR_2Confirmed

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0xD508 = -11000 → -1100010 = -1,100 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum dynamic charge current limit Q8_E_TRON_BMS_I_CHG_LIM_DYNConfirmed

  • Service 22DID 1E1B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0077 = 119 → 119 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum dynamic discharge current limit Q8_E_TRON_BMS_I_DCHG_LIM_DYNConfirmed

  • Service 22DID 1E1C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0404 = 1028 → 1,028 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum predicted charge current limit Q8_E_TRON_BMS_I_CHG_LIM_PREDConfirmed

  • Service 22DID 1E1D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0025 = 37 → 37 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Maximum predicted discharge current limit Q8_E_TRON_BMS_I_DCHG_LIM_PREDConfirmed

  • Service 22DID 1E1E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0190 = 400 → 400 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Minimum discharge voltage Q8_E_TRON_BMS_V_DCHG_MINConfirmed

  • Service 22DID 5170
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0ABE = 2750 → 275010 = 275 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Minimum dynamic charge voltage Q8_E_TRON_BMS_V_CHG_DYN_MINConfirmed

  • Service 22DID 5174
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0FD7 = 4055 → 405510 = 405.5 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Minimum dynamic discharge voltage Q8_E_TRON_BMS_V_DCHG_DYN_MINConfirmed

  • Service 22DID 5175
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0E47 = 3655 → 365510 = 365.5 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Minimum predicted charge voltage Q8_E_TRON_BMS_V_CHG_PRED_MINConfirmed

  • Service 22DID 5172
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0FA4 = 4004 → 400410 = 400.4 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Minimum predicted discharge voltage Q8_E_TRON_BMS_V_DCHG_PRED_MINConfirmed

  • Service 22DID 5173
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0EE4 = 3812 → 381210 = 381.2 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Non-vehicle energy requirement Q8_NV_ENERGY_REQUIREMENT

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2018 to 2023, 2025. Not supported for 2024.

On-board charger, hv/dc current Q8_OBC_HVDC_C

  • Service 22DID 103D
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2018 to 2023, 2025. Not supported for 2024.

Power efficiency Q8_E_TRON_CHRGR_EFFICIENCYConfirmed

  • Service 22DID 15D6
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
75 to 100.5 A
Unit
A

0xFE = 254 → 25410+75 = 100.4 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Power loss battery charger Q8_E_TRON_CHRGR_PWR_LOSSConfirmed

  • Service 22DID 15E1
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100
Unit
Raw value

0x00 = 0 → 0×20 = 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Proximity voltage, charging connector b Q8_E_TRON_CHRGR_PRX_V_CONN_BConfirmed

  • Service 22DID 1529
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x1129 = 4393 → 4,393 mV

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Rail 1 energy transformation Q8_E_TRON_CHRGR_RAIL1_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x000073 = 115 → 11510 = 11.5 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Rail 2 energy transformation Q8_E_TRON_CHRGR_RAIL2_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 24 to 47 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x00006E = 110 → 11010 = 11 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Rail 3 energy transformation Q8_E_TRON_CHRGR_RAIL3_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 48 to 71 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x00006E = 110 → 11010 = 11 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Temperature sensor, socket a Q8_E_TRON_OBC_T_AConfirmed

  • Service 22DID 1DDA
  • Module744 → 7AE
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498.5 °C
Unit
°C

0x00FF = 255 → 25510−55 = -29.5 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Temperature, 12V battery Q8_AUX_BAT_T

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Temperature, 12V battery sensor Q8_AUX_BAT_T_S

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Usable battery charge Q8_E_TRON_TRON_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x29 = 41 → 41 Ah

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Voltage proximity, socket a Q8_E_TRON_OBC_V_PROX_AConfirmed

  • Service 22DID 1525
  • Module744 → 7AE
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x1129 = 4393 → 4,393 mV

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cells

HV battery module 1 cell 1 state of charge Q8_E_TRON_HVBAT_MOD1_C1_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 1 voltage Q8_E_TRON_HVBAT_MOD1_C1_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 2 state of charge Q8_E_TRON_HVBAT_MOD1_C2_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 2 voltage Q8_E_TRON_HVBAT_MOD1_C2_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 3 state of charge Q8_E_TRON_HVBAT_MOD1_C3_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 3 voltage Q8_E_TRON_HVBAT_MOD1_C3_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 4 state of charge Q8_E_TRON_HVBAT_MOD1_C4_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 4 voltage Q8_E_TRON_HVBAT_MOD1_C4_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 5 state of charge Q8_E_TRON_HVBAT_MOD1_C5_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 5 voltage Q8_E_TRON_HVBAT_MOD1_C5_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 6 state of charge Q8_E_TRON_HVBAT_MOD1_C6_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 cell 6 voltage Q8_E_TRON_HVBAT_MOD1_C6_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 1 id Q8_E_TRON_HVBAT_MOD1_ID

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 1 state of charge Q8_E_TRON_HVBAT_MOD2_C1_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 1 voltage Q8_E_TRON_HVBAT_MOD2_C1_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 2 state of charge Q8_E_TRON_HVBAT_MOD2_C2_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 2 voltage Q8_E_TRON_HVBAT_MOD2_C2_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 3 state of charge Q8_E_TRON_HVBAT_MOD2_C3_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 3 voltage Q8_E_TRON_HVBAT_MOD2_C3_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 4 state of charge Q8_E_TRON_HVBAT_MOD2_C4_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 4 voltage Q8_E_TRON_HVBAT_MOD2_C4_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 5 state of charge Q8_E_TRON_HVBAT_MOD2_C5_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 5 voltage Q8_E_TRON_HVBAT_MOD2_C5_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 6 state of charge Q8_E_TRON_HVBAT_MOD2_C6_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 cell 6 voltage Q8_E_TRON_HVBAT_MOD2_C6_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 2 id Q8_E_TRON_HVBAT_MOD2_ID

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 1 state of charge Q8_E_TRON_HVBAT_MOD3_C1_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 1 voltage Q8_E_TRON_HVBAT_MOD3_C1_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 2 state of charge Q8_E_TRON_HVBAT_MOD3_C2_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 2 voltage Q8_E_TRON_HVBAT_MOD3_C2_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 3 state of charge Q8_E_TRON_HVBAT_MOD3_C3_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 3 voltage Q8_E_TRON_HVBAT_MOD3_C3_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 4 state of charge Q8_E_TRON_HVBAT_MOD3_C4_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 4 voltage Q8_E_TRON_HVBAT_MOD3_C4_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 5 state of charge Q8_E_TRON_HVBAT_MOD3_C5_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 5 voltage Q8_E_TRON_HVBAT_MOD3_C5_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 6 state of charge Q8_E_TRON_HVBAT_MOD3_C6_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 cell 6 voltage Q8_E_TRON_HVBAT_MOD3_C6_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 3 id Q8_E_TRON_HVBAT_MOD3_ID

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 1 state of charge Q8_E_TRON_HVBAT_MOD4_C1_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 1 voltage Q8_E_TRON_HVBAT_MOD4_C1_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 2 state of charge Q8_E_TRON_HVBAT_MOD4_C2_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 2 voltage Q8_E_TRON_HVBAT_MOD4_C2_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 3 state of charge Q8_E_TRON_HVBAT_MOD4_C3_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 3 voltage Q8_E_TRON_HVBAT_MOD4_C3_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 4 state of charge Q8_E_TRON_HVBAT_MOD4_C4_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 4 voltage Q8_E_TRON_HVBAT_MOD4_C4_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 5 state of charge Q8_E_TRON_HVBAT_MOD4_C5_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 5 voltage Q8_E_TRON_HVBAT_MOD4_C5_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 6 state of charge Q8_E_TRON_HVBAT_MOD4_C6_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 cell 6 voltage Q8_E_TRON_HVBAT_MOD4_C6_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 4 id Q8_E_TRON_HVBAT_MOD4_ID

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 1 state of charge Q8_E_TRON_HVBAT_MOD5_C1_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 1 voltage Q8_E_TRON_HVBAT_MOD5_C1_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 2 state of charge Q8_E_TRON_HVBAT_MOD5_C2_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 2 voltage Q8_E_TRON_HVBAT_MOD5_C2_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 3 state of charge Q8_E_TRON_HVBAT_MOD5_C3_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 3 voltage Q8_E_TRON_HVBAT_MOD5_C3_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 4 state of charge Q8_E_TRON_HVBAT_MOD5_C4_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 4 voltage Q8_E_TRON_HVBAT_MOD5_C4_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 5 state of charge Q8_E_TRON_HVBAT_MOD5_C5_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 5 voltage Q8_E_TRON_HVBAT_MOD5_C5_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 6 state of charge Q8_E_TRON_HVBAT_MOD5_C6_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 cell 6 voltage Q8_E_TRON_HVBAT_MOD5_C6_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 5 id Q8_E_TRON_HVBAT_MOD5_ID

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 1 state of charge Q8_E_TRON_HVBAT_MOD6_C1_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 1 voltage Q8_E_TRON_HVBAT_MOD6_C1_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 2 state of charge Q8_E_TRON_HVBAT_MOD6_C2_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 2 voltage Q8_E_TRON_HVBAT_MOD6_C2_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 3 state of charge Q8_E_TRON_HVBAT_MOD6_C3_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 3 voltage Q8_E_TRON_HVBAT_MOD6_C3_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 4 state of charge Q8_E_TRON_HVBAT_MOD6_C4_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 4 voltage Q8_E_TRON_HVBAT_MOD6_C4_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 5 state of charge Q8_E_TRON_HVBAT_MOD6_C5_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 5 voltage Q8_E_TRON_HVBAT_MOD6_C5_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 6 state of charge Q8_E_TRON_HVBAT_MOD6_C6_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 cell 6 voltage Q8_E_TRON_HVBAT_MOD6_C6_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 6 id Q8_E_TRON_HVBAT_MOD6_ID

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 1 state of charge Q8_E_TRON_HVBAT_MOD7_C1_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 1 voltage Q8_E_TRON_HVBAT_MOD7_C1_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 2 state of charge Q8_E_TRON_HVBAT_MOD7_C2_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 2 voltage Q8_E_TRON_HVBAT_MOD7_C2_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 3 state of charge Q8_E_TRON_HVBAT_MOD7_C3_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 3 voltage Q8_E_TRON_HVBAT_MOD7_C3_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 4 state of charge Q8_E_TRON_HVBAT_MOD7_C4_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 4 voltage Q8_E_TRON_HVBAT_MOD7_C4_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 5 state of charge Q8_E_TRON_HVBAT_MOD7_C5_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 5 voltage Q8_E_TRON_HVBAT_MOD7_C5_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 6 state of charge Q8_E_TRON_HVBAT_MOD7_C6_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 cell 6 voltage Q8_E_TRON_HVBAT_MOD7_C6_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 7 id Q8_E_TRON_HVBAT_MOD7_ID

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 1 state of charge Q8_E_TRON_HVBAT_MOD8_C1_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 1 voltage Q8_E_TRON_HVBAT_MOD8_C1_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 2 state of charge Q8_E_TRON_HVBAT_MOD8_C2_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 2 voltage Q8_E_TRON_HVBAT_MOD8_C2_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 3 state of charge Q8_E_TRON_HVBAT_MOD8_C3_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 3 voltage Q8_E_TRON_HVBAT_MOD8_C3_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 4 state of charge Q8_E_TRON_HVBAT_MOD8_C4_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 4 voltage Q8_E_TRON_HVBAT_MOD8_C4_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 5 state of charge Q8_E_TRON_HVBAT_MOD8_C5_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 5 voltage Q8_E_TRON_HVBAT_MOD8_C5_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 6 state of charge Q8_E_TRON_HVBAT_MOD8_C6_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 cell 6 voltage Q8_E_TRON_HVBAT_MOD8_C6_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 8 id Q8_E_TRON_HVBAT_MOD8_ID

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 1 state of charge Q8_E_TRON_HVBAT_MOD9_C1_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 1 voltage Q8_E_TRON_HVBAT_MOD9_C1_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 2 state of charge Q8_E_TRON_HVBAT_MOD9_C2_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 2 voltage Q8_E_TRON_HVBAT_MOD9_C2_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 3 state of charge Q8_E_TRON_HVBAT_MOD9_C3_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 3 voltage Q8_E_TRON_HVBAT_MOD9_C3_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 4 state of charge Q8_E_TRON_HVBAT_MOD9_C4_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 4 voltage Q8_E_TRON_HVBAT_MOD9_C4_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 5 state of charge Q8_E_TRON_HVBAT_MOD9_C5_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 5 voltage Q8_E_TRON_HVBAT_MOD9_C5_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 6 state of charge Q8_E_TRON_HVBAT_MOD9_C6_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 cell 6 voltage Q8_E_TRON_HVBAT_MOD9_C6_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 9 id Q8_E_TRON_HVBAT_MOD9_ID

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 1 state of charge Q8_E_TRON_HVBAT_MOD10_C1_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 1 voltage Q8_E_TRON_HVBAT_MOD10_C1_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 2 state of charge Q8_E_TRON_HVBAT_MOD10_C2_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 2 voltage Q8_E_TRON_HVBAT_MOD10_C2_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 3 state of charge Q8_E_TRON_HVBAT_MOD10_C3_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 3 voltage Q8_E_TRON_HVBAT_MOD10_C3_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 4 state of charge Q8_E_TRON_HVBAT_MOD10_C4_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 4 voltage Q8_E_TRON_HVBAT_MOD10_C4_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 5 state of charge Q8_E_TRON_HVBAT_MOD10_C5_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 5 voltage Q8_E_TRON_HVBAT_MOD10_C5_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 6 state of charge Q8_E_TRON_HVBAT_MOD10_C6_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 cell 6 voltage Q8_E_TRON_HVBAT_MOD10_C6_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 10 id Q8_E_TRON_HVBAT_MOD10_ID

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 1 state of charge Q8_E_TRON_HVBAT_MOD11_C1_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 1 voltage Q8_E_TRON_HVBAT_MOD11_C1_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 2 state of charge Q8_E_TRON_HVBAT_MOD11_C2_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 2 voltage Q8_E_TRON_HVBAT_MOD11_C2_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 3 state of charge Q8_E_TRON_HVBAT_MOD11_C3_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 3 voltage Q8_E_TRON_HVBAT_MOD11_C3_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 4 state of charge Q8_E_TRON_HVBAT_MOD11_C4_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 4 voltage Q8_E_TRON_HVBAT_MOD11_C4_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 5 state of charge Q8_E_TRON_HVBAT_MOD11_C5_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 5 voltage Q8_E_TRON_HVBAT_MOD11_C5_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 6 state of charge Q8_E_TRON_HVBAT_MOD11_C6_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 cell 6 voltage Q8_E_TRON_HVBAT_MOD11_C6_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 11 id Q8_E_TRON_HVBAT_MOD11_ID

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 1 state of charge Q8_E_TRON_HVBAT_MOD12_C1_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 1 voltage Q8_E_TRON_HVBAT_MOD12_C1_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 2 state of charge Q8_E_TRON_HVBAT_MOD12_C2_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 2 voltage Q8_E_TRON_HVBAT_MOD12_C2_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 3 state of charge Q8_E_TRON_HVBAT_MOD12_C3_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 3 voltage Q8_E_TRON_HVBAT_MOD12_C3_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 4 state of charge Q8_E_TRON_HVBAT_MOD12_C4_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 4 voltage Q8_E_TRON_HVBAT_MOD12_C4_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 5 state of charge Q8_E_TRON_HVBAT_MOD12_C5_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 5 voltage Q8_E_TRON_HVBAT_MOD12_C5_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 6 state of charge Q8_E_TRON_HVBAT_MOD12_C6_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 cell 6 voltage Q8_E_TRON_HVBAT_MOD12_C6_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 12 id Q8_E_TRON_HVBAT_MOD12_ID

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 1 state of charge Q8_E_TRON_HVBAT_MOD13_C1_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 1 voltage Q8_E_TRON_HVBAT_MOD13_C1_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 2 state of charge Q8_E_TRON_HVBAT_MOD13_C2_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 2 voltage Q8_E_TRON_HVBAT_MOD13_C2_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 3 state of charge Q8_E_TRON_HVBAT_MOD13_C3_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 3 voltage Q8_E_TRON_HVBAT_MOD13_C3_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 4 state of charge Q8_E_TRON_HVBAT_MOD13_C4_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 4 voltage Q8_E_TRON_HVBAT_MOD13_C4_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 5 state of charge Q8_E_TRON_HVBAT_MOD13_C5_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 5 voltage Q8_E_TRON_HVBAT_MOD13_C5_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 6 state of charge Q8_E_TRON_HVBAT_MOD13_C6_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 cell 6 voltage Q8_E_TRON_HVBAT_MOD13_C6_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 13 id Q8_E_TRON_HVBAT_MOD13_ID

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 1 state of charge Q8_E_TRON_HVBAT_MOD14_C1_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 1 voltage Q8_E_TRON_HVBAT_MOD14_C1_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 2 state of charge Q8_E_TRON_HVBAT_MOD14_C2_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 2 voltage Q8_E_TRON_HVBAT_MOD14_C2_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 3 state of charge Q8_E_TRON_HVBAT_MOD14_C3_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 3 voltage Q8_E_TRON_HVBAT_MOD14_C3_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 4 state of charge Q8_E_TRON_HVBAT_MOD14_C4_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 4 voltage Q8_E_TRON_HVBAT_MOD14_C4_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 5 state of charge Q8_E_TRON_HVBAT_MOD14_C5_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 5 voltage Q8_E_TRON_HVBAT_MOD14_C5_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 6 state of charge Q8_E_TRON_HVBAT_MOD14_C6_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 cell 6 voltage Q8_E_TRON_HVBAT_MOD14_C6_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 14 id Q8_E_TRON_HVBAT_MOD14_ID

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 1 state of charge Q8_E_TRON_HVBAT_MOD15_C1_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 1 voltage Q8_E_TRON_HVBAT_MOD15_C1_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 2 state of charge Q8_E_TRON_HVBAT_MOD15_C2_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 2 voltage Q8_E_TRON_HVBAT_MOD15_C2_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 3 state of charge Q8_E_TRON_HVBAT_MOD15_C3_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 3 voltage Q8_E_TRON_HVBAT_MOD15_C3_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 4 state of charge Q8_E_TRON_HVBAT_MOD15_C4_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 4 voltage Q8_E_TRON_HVBAT_MOD15_C4_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 5 state of charge Q8_E_TRON_HVBAT_MOD15_C5_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 5 voltage Q8_E_TRON_HVBAT_MOD15_C5_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 6 state of charge Q8_E_TRON_HVBAT_MOD15_C6_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 cell 6 voltage Q8_E_TRON_HVBAT_MOD15_C6_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 15 id Q8_E_TRON_HVBAT_MOD15_ID

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 1 state of charge Q8_E_TRON_HVBAT_MOD16_C1_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 1 voltage Q8_E_TRON_HVBAT_MOD16_C1_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 2 state of charge Q8_E_TRON_HVBAT_MOD16_C2_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 2 voltage Q8_E_TRON_HVBAT_MOD16_C2_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 3 state of charge Q8_E_TRON_HVBAT_MOD16_C3_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 3 voltage Q8_E_TRON_HVBAT_MOD16_C3_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 4 state of charge Q8_E_TRON_HVBAT_MOD16_C4_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 4 voltage Q8_E_TRON_HVBAT_MOD16_C4_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 5 state of charge Q8_E_TRON_HVBAT_MOD16_C5_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 5 voltage Q8_E_TRON_HVBAT_MOD16_C5_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 6 state of charge Q8_E_TRON_HVBAT_MOD16_C6_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 cell 6 voltage Q8_E_TRON_HVBAT_MOD16_C6_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 16 id Q8_E_TRON_HVBAT_MOD16_ID

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 1 state of charge Q8_E_TRON_HVBAT_MOD17_C1_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 1 voltage Q8_E_TRON_HVBAT_MOD17_C1_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 2 state of charge Q8_E_TRON_HVBAT_MOD17_C2_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 2 voltage Q8_E_TRON_HVBAT_MOD17_C2_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 3 state of charge Q8_E_TRON_HVBAT_MOD17_C3_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 3 voltage Q8_E_TRON_HVBAT_MOD17_C3_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 4 state of charge Q8_E_TRON_HVBAT_MOD17_C4_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 4 voltage Q8_E_TRON_HVBAT_MOD17_C4_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 5 state of charge Q8_E_TRON_HVBAT_MOD17_C5_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 5 voltage Q8_E_TRON_HVBAT_MOD17_C5_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 6 state of charge Q8_E_TRON_HVBAT_MOD17_C6_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 cell 6 voltage Q8_E_TRON_HVBAT_MOD17_C6_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 17 id Q8_E_TRON_HVBAT_MOD17_ID

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 1 state of charge Q8_E_TRON_HVBAT_MOD18_C1_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 1 voltage Q8_E_TRON_HVBAT_MOD18_C1_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 2 state of charge Q8_E_TRON_HVBAT_MOD18_C2_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 2 voltage Q8_E_TRON_HVBAT_MOD18_C2_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 3 state of charge Q8_E_TRON_HVBAT_MOD18_C3_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 3 voltage Q8_E_TRON_HVBAT_MOD18_C3_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 4 state of charge Q8_E_TRON_HVBAT_MOD18_C4_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 4 voltage Q8_E_TRON_HVBAT_MOD18_C4_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 5 state of charge Q8_E_TRON_HVBAT_MOD18_C5_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 5 voltage Q8_E_TRON_HVBAT_MOD18_C5_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 6 state of charge Q8_E_TRON_HVBAT_MOD18_C6_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 cell 6 voltage Q8_E_TRON_HVBAT_MOD18_C6_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 18 id Q8_E_TRON_HVBAT_MOD18_ID

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 1 state of charge Q8_E_TRON_HVBAT_MOD19_C1_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 1 voltage Q8_E_TRON_HVBAT_MOD19_C1_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 2 state of charge Q8_E_TRON_HVBAT_MOD19_C2_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 2 voltage Q8_E_TRON_HVBAT_MOD19_C2_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 3 state of charge Q8_E_TRON_HVBAT_MOD19_C3_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 3 voltage Q8_E_TRON_HVBAT_MOD19_C3_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 4 state of charge Q8_E_TRON_HVBAT_MOD19_C4_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 4 voltage Q8_E_TRON_HVBAT_MOD19_C4_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 5 state of charge Q8_E_TRON_HVBAT_MOD19_C5_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 5 voltage Q8_E_TRON_HVBAT_MOD19_C5_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 6 state of charge Q8_E_TRON_HVBAT_MOD19_C6_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 cell 6 voltage Q8_E_TRON_HVBAT_MOD19_C6_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 19 id Q8_E_TRON_HVBAT_MOD19_ID

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 1 state of charge Q8_E_TRON_HVBAT_MOD20_C1_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 1 voltage Q8_E_TRON_HVBAT_MOD20_C1_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 2 state of charge Q8_E_TRON_HVBAT_MOD20_C2_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 2 voltage Q8_E_TRON_HVBAT_MOD20_C2_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 3 state of charge Q8_E_TRON_HVBAT_MOD20_C3_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 3 voltage Q8_E_TRON_HVBAT_MOD20_C3_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 4 state of charge Q8_E_TRON_HVBAT_MOD20_C4_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 4 voltage Q8_E_TRON_HVBAT_MOD20_C4_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 5 state of charge Q8_E_TRON_HVBAT_MOD20_C5_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 5 voltage Q8_E_TRON_HVBAT_MOD20_C5_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 6 state of charge Q8_E_TRON_HVBAT_MOD20_C6_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 cell 6 voltage Q8_E_TRON_HVBAT_MOD20_C6_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 20 id Q8_E_TRON_HVBAT_MOD20_ID

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 1 state of charge Q8_E_TRON_HVBAT_MOD21_C1_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 1 voltage Q8_E_TRON_HVBAT_MOD21_C1_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 2 state of charge Q8_E_TRON_HVBAT_MOD21_C2_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 2 voltage Q8_E_TRON_HVBAT_MOD21_C2_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 3 state of charge Q8_E_TRON_HVBAT_MOD21_C3_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 3 voltage Q8_E_TRON_HVBAT_MOD21_C3_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 4 state of charge Q8_E_TRON_HVBAT_MOD21_C4_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 4 voltage Q8_E_TRON_HVBAT_MOD21_C4_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 5 state of charge Q8_E_TRON_HVBAT_MOD21_C5_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 5 voltage Q8_E_TRON_HVBAT_MOD21_C5_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 6 state of charge Q8_E_TRON_HVBAT_MOD21_C6_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 cell 6 voltage Q8_E_TRON_HVBAT_MOD21_C6_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 21 id Q8_E_TRON_HVBAT_MOD21_ID

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 1 state of charge Q8_E_TRON_HVBAT_MOD22_C1_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 1 voltage Q8_E_TRON_HVBAT_MOD22_C1_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 2 state of charge Q8_E_TRON_HVBAT_MOD22_C2_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 2 voltage Q8_E_TRON_HVBAT_MOD22_C2_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 3 state of charge Q8_E_TRON_HVBAT_MOD22_C3_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 3 voltage Q8_E_TRON_HVBAT_MOD22_C3_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 4 state of charge Q8_E_TRON_HVBAT_MOD22_C4_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 4 voltage Q8_E_TRON_HVBAT_MOD22_C4_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 5 state of charge Q8_E_TRON_HVBAT_MOD22_C5_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 5 voltage Q8_E_TRON_HVBAT_MOD22_C5_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 6 state of charge Q8_E_TRON_HVBAT_MOD22_C6_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 cell 6 voltage Q8_E_TRON_HVBAT_MOD22_C6_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 22 id Q8_E_TRON_HVBAT_MOD22_ID

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 1 state of charge Q8_E_TRON_HVBAT_MOD23_C1_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 1 voltage Q8_E_TRON_HVBAT_MOD23_C1_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 2 state of charge Q8_E_TRON_HVBAT_MOD23_C2_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 2 voltage Q8_E_TRON_HVBAT_MOD23_C2_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 3 state of charge Q8_E_TRON_HVBAT_MOD23_C3_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 3 voltage Q8_E_TRON_HVBAT_MOD23_C3_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 4 state of charge Q8_E_TRON_HVBAT_MOD23_C4_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 4 voltage Q8_E_TRON_HVBAT_MOD23_C4_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 5 state of charge Q8_E_TRON_HVBAT_MOD23_C5_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 5 voltage Q8_E_TRON_HVBAT_MOD23_C5_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 6 state of charge Q8_E_TRON_HVBAT_MOD23_C6_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 cell 6 voltage Q8_E_TRON_HVBAT_MOD23_C6_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 23 id Q8_E_TRON_HVBAT_MOD23_ID

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 1 state of charge Q8_E_TRON_HVBAT_MOD24_C1_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 1 voltage Q8_E_TRON_HVBAT_MOD24_C1_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 2 state of charge Q8_E_TRON_HVBAT_MOD24_C2_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 2 voltage Q8_E_TRON_HVBAT_MOD24_C2_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 3 state of charge Q8_E_TRON_HVBAT_MOD24_C3_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 3 voltage Q8_E_TRON_HVBAT_MOD24_C3_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 4 state of charge Q8_E_TRON_HVBAT_MOD24_C4_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 4 voltage Q8_E_TRON_HVBAT_MOD24_C4_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 5 state of charge Q8_E_TRON_HVBAT_MOD24_C5_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 5 voltage Q8_E_TRON_HVBAT_MOD24_C5_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 6 state of charge Q8_E_TRON_HVBAT_MOD24_C6_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 cell 6 voltage Q8_E_TRON_HVBAT_MOD24_C6_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 24 id Q8_E_TRON_HVBAT_MOD24_ID

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 1 state of charge Q8_E_TRON_HVBAT_MOD25_C1_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 1 voltage Q8_E_TRON_HVBAT_MOD25_C1_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 2 state of charge Q8_E_TRON_HVBAT_MOD25_C2_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 2 voltage Q8_E_TRON_HVBAT_MOD25_C2_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 3 state of charge Q8_E_TRON_HVBAT_MOD25_C3_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 3 voltage Q8_E_TRON_HVBAT_MOD25_C3_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 4 state of charge Q8_E_TRON_HVBAT_MOD25_C4_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 4 voltage Q8_E_TRON_HVBAT_MOD25_C4_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 5 state of charge Q8_E_TRON_HVBAT_MOD25_C5_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 5 voltage Q8_E_TRON_HVBAT_MOD25_C5_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 6 state of charge Q8_E_TRON_HVBAT_MOD25_C6_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 cell 6 voltage Q8_E_TRON_HVBAT_MOD25_C6_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 25 id Q8_E_TRON_HVBAT_MOD25_ID

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 1 state of charge Q8_E_TRON_HVBAT_MOD26_C1_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 1 voltage Q8_E_TRON_HVBAT_MOD26_C1_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 2 state of charge Q8_E_TRON_HVBAT_MOD26_C2_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 2 voltage Q8_E_TRON_HVBAT_MOD26_C2_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 3 state of charge Q8_E_TRON_HVBAT_MOD26_C3_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 3 voltage Q8_E_TRON_HVBAT_MOD26_C3_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 4 state of charge Q8_E_TRON_HVBAT_MOD26_C4_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 4 voltage Q8_E_TRON_HVBAT_MOD26_C4_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 5 state of charge Q8_E_TRON_HVBAT_MOD26_C5_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 5 voltage Q8_E_TRON_HVBAT_MOD26_C5_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 6 state of charge Q8_E_TRON_HVBAT_MOD26_C6_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 cell 6 voltage Q8_E_TRON_HVBAT_MOD26_C6_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 26 id Q8_E_TRON_HVBAT_MOD26_ID

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 1 state of charge Q8_E_TRON_HVBAT_MOD27_C1_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 1 voltage Q8_E_TRON_HVBAT_MOD27_C1_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 2 state of charge Q8_E_TRON_HVBAT_MOD27_C2_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 2 voltage Q8_E_TRON_HVBAT_MOD27_C2_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 3 state of charge Q8_E_TRON_HVBAT_MOD27_C3_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 3 voltage Q8_E_TRON_HVBAT_MOD27_C3_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 4 state of charge Q8_E_TRON_HVBAT_MOD27_C4_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 4 voltage Q8_E_TRON_HVBAT_MOD27_C4_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 5 state of charge Q8_E_TRON_HVBAT_MOD27_C5_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 5 voltage Q8_E_TRON_HVBAT_MOD27_C5_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 6 state of charge Q8_E_TRON_HVBAT_MOD27_C6_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 cell 6 voltage Q8_E_TRON_HVBAT_MOD27_C6_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 27 id Q8_E_TRON_HVBAT_MOD27_ID

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 1 state of charge Q8_E_TRON_HVBAT_MOD28_C1_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 1 voltage Q8_E_TRON_HVBAT_MOD28_C1_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 2 state of charge Q8_E_TRON_HVBAT_MOD28_C2_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 2 voltage Q8_E_TRON_HVBAT_MOD28_C2_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 3 state of charge Q8_E_TRON_HVBAT_MOD28_C3_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 3 voltage Q8_E_TRON_HVBAT_MOD28_C3_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 4 state of charge Q8_E_TRON_HVBAT_MOD28_C4_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 4 voltage Q8_E_TRON_HVBAT_MOD28_C4_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 5 state of charge Q8_E_TRON_HVBAT_MOD28_C5_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 5 voltage Q8_E_TRON_HVBAT_MOD28_C5_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 6 state of charge Q8_E_TRON_HVBAT_MOD28_C6_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 cell 6 voltage Q8_E_TRON_HVBAT_MOD28_C6_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 28 id Q8_E_TRON_HVBAT_MOD28_ID

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 1 state of charge Q8_E_TRON_HVBAT_MOD29_C1_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 1 voltage Q8_E_TRON_HVBAT_MOD29_C1_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 2 state of charge Q8_E_TRON_HVBAT_MOD29_C2_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 2 voltage Q8_E_TRON_HVBAT_MOD29_C2_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 3 state of charge Q8_E_TRON_HVBAT_MOD29_C3_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 3 voltage Q8_E_TRON_HVBAT_MOD29_C3_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 4 state of charge Q8_E_TRON_HVBAT_MOD29_C4_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 4 voltage Q8_E_TRON_HVBAT_MOD29_C4_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 5 state of charge Q8_E_TRON_HVBAT_MOD29_C5_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 5 voltage Q8_E_TRON_HVBAT_MOD29_C5_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 6 state of charge Q8_E_TRON_HVBAT_MOD29_C6_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 cell 6 voltage Q8_E_TRON_HVBAT_MOD29_C6_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 29 id Q8_E_TRON_HVBAT_MOD29_ID

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 1 state of charge Q8_E_TRON_HVBAT_MOD30_C1_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 1 voltage Q8_E_TRON_HVBAT_MOD30_C1_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 2 state of charge Q8_E_TRON_HVBAT_MOD30_C2_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 2 voltage Q8_E_TRON_HVBAT_MOD30_C2_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 3 state of charge Q8_E_TRON_HVBAT_MOD30_C3_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 3 voltage Q8_E_TRON_HVBAT_MOD30_C3_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 4 state of charge Q8_E_TRON_HVBAT_MOD30_C4_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 4 voltage Q8_E_TRON_HVBAT_MOD30_C4_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 5 state of charge Q8_E_TRON_HVBAT_MOD30_C5_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 5 voltage Q8_E_TRON_HVBAT_MOD30_C5_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 6 state of charge Q8_E_TRON_HVBAT_MOD30_C6_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 cell 6 voltage Q8_E_TRON_HVBAT_MOD30_C6_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 30 id Q8_E_TRON_HVBAT_MOD30_ID

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 1 state of charge Q8_E_TRON_HVBAT_MOD31_C1_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 1 voltage Q8_E_TRON_HVBAT_MOD31_C1_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 2 state of charge Q8_E_TRON_HVBAT_MOD31_C2_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 2 voltage Q8_E_TRON_HVBAT_MOD31_C2_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 3 state of charge Q8_E_TRON_HVBAT_MOD31_C3_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 3 voltage Q8_E_TRON_HVBAT_MOD31_C3_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 4 state of charge Q8_E_TRON_HVBAT_MOD31_C4_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 4 voltage Q8_E_TRON_HVBAT_MOD31_C4_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 5 state of charge Q8_E_TRON_HVBAT_MOD31_C5_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 5 voltage Q8_E_TRON_HVBAT_MOD31_C5_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 6 state of charge Q8_E_TRON_HVBAT_MOD31_C6_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 cell 6 voltage Q8_E_TRON_HVBAT_MOD31_C6_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 id Q8_E_TRON_HVBAT_MOD31_ID

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 31 id Q8_E_TRON_HVBAT_MOD33_ID

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 1 state of charge Q8_E_TRON_HVBAT_MOD32_C1_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 1 voltage Q8_E_TRON_HVBAT_MOD32_C1_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 2 state of charge Q8_E_TRON_HVBAT_MOD32_C2_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 2 voltage Q8_E_TRON_HVBAT_MOD32_C2_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 3 state of charge Q8_E_TRON_HVBAT_MOD32_C3_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 3 voltage Q8_E_TRON_HVBAT_MOD32_C3_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 4 state of charge Q8_E_TRON_HVBAT_MOD32_C4_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 4 voltage Q8_E_TRON_HVBAT_MOD32_C4_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 5 state of charge Q8_E_TRON_HVBAT_MOD32_C5_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 5 voltage Q8_E_TRON_HVBAT_MOD32_C5_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 6 state of charge Q8_E_TRON_HVBAT_MOD32_C6_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 cell 6 voltage Q8_E_TRON_HVBAT_MOD32_C6_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 32 id Q8_E_TRON_HVBAT_MOD32_ID

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 1 state of charge Q8_E_TRON_HVBAT_MOD33_C1_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 1 voltage Q8_E_TRON_HVBAT_MOD33_C1_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 2 state of charge Q8_E_TRON_HVBAT_MOD33_C2_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 2 voltage Q8_E_TRON_HVBAT_MOD33_C2_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 3 state of charge Q8_E_TRON_HVBAT_MOD33_C3_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 3 voltage Q8_E_TRON_HVBAT_MOD33_C3_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 4 state of charge Q8_E_TRON_HVBAT_MOD33_C4_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 4 voltage Q8_E_TRON_HVBAT_MOD33_C4_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 5 state of charge Q8_E_TRON_HVBAT_MOD33_C5_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 5 voltage Q8_E_TRON_HVBAT_MOD33_C5_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 6 state of charge Q8_E_TRON_HVBAT_MOD33_C6_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2023, 2025. Not supported for 2024.

HV battery module 33 cell 6 voltage Q8_E_TRON_HVBAT_MOD33_C6_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2018 to 2023, 2025. Not supported for 2024.

Internal

Average battery consumption Q8_E_TRON_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x26 = 38 → 38 A

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Estimated electric power reserve Q8_E_TRON_RANGE_EST_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00AB = 171 → 171 km

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Modules

Module 1, temperature 1 Q8_E_TRON_HVBAT_MOD1_T1

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 1, temperature 2 Q8_E_TRON_HVBAT_MOD1_T2

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 1, temperature 3 Q8_E_TRON_HVBAT_MOD1_T3

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 2, temperature 1 Q8_E_TRON_HVBAT_MOD2_T1

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 2, temperature 2 Q8_E_TRON_HVBAT_MOD2_T2

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 2, temperature 3 Q8_E_TRON_HVBAT_MOD2_T3

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 3, temperature 1 Q8_E_TRON_HVBAT_MOD3_T1Confirmed

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x00 = 0 → 0−50 = -50 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Module 3, temperature 2 Q8_E_TRON_HVBAT_MOD3_T2

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Supported for 2024.

Module 3, temperature 3 Q8_E_TRON_HVBAT_MOD3_T3

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Supported for 2024.

Module 4, temperature 1 Q8_E_TRON_HVBAT_MOD4_T1

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 4, temperature 2 Q8_E_TRON_HVBAT_MOD4_T2

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 4, temperature 3 Q8_E_TRON_HVBAT_MOD4_T3

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 5, temperature 1 Q8_E_TRON_HVBAT_MOD5_T1

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 5, temperature 2 Q8_E_TRON_HVBAT_MOD5_T2

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 5, temperature 3 Q8_E_TRON_HVBAT_MOD5_T3

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 6, temperature 1 Q8_E_TRON_HVBAT_MOD6_T1

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 6, temperature 2 Q8_E_TRON_HVBAT_MOD6_T2

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 6, temperature 3 Q8_E_TRON_HVBAT_MOD6_T3

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 7, temperature 1 Q8_E_TRON_HVBAT_MOD7_T1

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 7, temperature 2 Q8_E_TRON_HVBAT_MOD7_T2

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 7, temperature 3 Q8_E_TRON_HVBAT_MOD7_T3

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 8, temperature 1 Q8_E_TRON_HVBAT_MOD8_T1

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 8, temperature 2 Q8_E_TRON_HVBAT_MOD8_T2

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 8, temperature 3 Q8_E_TRON_HVBAT_MOD8_T3

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 9, temperature 1 Q8_E_TRON_HVBAT_MOD9_T1

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 9, temperature 2 Q8_E_TRON_HVBAT_MOD9_T2

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 9, temperature 3 Q8_E_TRON_HVBAT_MOD9_T3

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 10, temperature 1 Q8_E_TRON_HVBAT_MOD10_T1

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 10, temperature 2 Q8_E_TRON_HVBAT_MOD10_T2

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 10, temperature 3 Q8_E_TRON_HVBAT_MOD10_T3

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 11, temperature 1 Q8_E_TRON_HVBAT_MOD11_T1

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 11, temperature 2 Q8_E_TRON_HVBAT_MOD11_T2

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 11, temperature 3 Q8_E_TRON_HVBAT_MOD11_T3

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 12, temperature 1 Q8_E_TRON_HVBAT_MOD12_T1

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 12, temperature 2 Q8_E_TRON_HVBAT_MOD12_T2

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 12, temperature 3 Q8_E_TRON_HVBAT_MOD12_T3

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 13, temperature 1 Q8_E_TRON_HVBAT_MOD13_T1

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 13, temperature 2 Q8_E_TRON_HVBAT_MOD13_T2

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 13, temperature 3 Q8_E_TRON_HVBAT_MOD13_T3

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 14, temperature 1 Q8_E_TRON_HVBAT_MOD14_T1

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 14, temperature 2 Q8_E_TRON_HVBAT_MOD14_T2

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 14, temperature 3 Q8_E_TRON_HVBAT_MOD14_T3

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 15, temperature 1 Q8_E_TRON_HVBAT_MOD15_T1

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 15, temperature 2 Q8_E_TRON_HVBAT_MOD15_T2

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 15, temperature 3 Q8_E_TRON_HVBAT_MOD15_T3

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 16, temperature 1 Q8_E_TRON_HVBAT_MOD16_T1

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 16, temperature 2 Q8_E_TRON_HVBAT_MOD16_T2

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 16, temperature 3 Q8_E_TRON_HVBAT_MOD16_T3

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 17, temperature 1 Q8_E_TRON_HVBAT_MOD17_T1

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 17, temperature 2 Q8_E_TRON_HVBAT_MOD17_T2

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 17, temperature 3 Q8_E_TRON_HVBAT_MOD17_T3

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 18, temperature 1 Q8_E_TRON_HVBAT_MOD18_T1

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 18, temperature 2 Q8_E_TRON_HVBAT_MOD18_T2

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 18, temperature 3 Q8_E_TRON_HVBAT_MOD18_T3

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 19, temperature 1 Q8_E_TRON_HVBAT_MOD19_T1

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 19, temperature 2 Q8_E_TRON_HVBAT_MOD19_T2

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 19, temperature 3 Q8_E_TRON_HVBAT_MOD19_T3

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 20, temperature 1 Q8_E_TRON_HVBAT_MOD20_T1

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 20, temperature 2 Q8_E_TRON_HVBAT_MOD20_T2

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 20, temperature 3 Q8_E_TRON_HVBAT_MOD20_T3

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 21, temperature 1 Q8_E_TRON_HVBAT_MOD21_T1

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 21, temperature 2 Q8_E_TRON_HVBAT_MOD21_T2

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 21, temperature 3 Q8_E_TRON_HVBAT_MOD21_T3

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 22, temperature 1 Q8_E_TRON_HVBAT_MOD22_T1

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 22, temperature 2 Q8_E_TRON_HVBAT_MOD22_T2

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 22, temperature 3 Q8_E_TRON_HVBAT_MOD22_T3

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 23, temperature 1 Q8_E_TRON_HVBAT_MOD23_T1

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 23, temperature 2 Q8_E_TRON_HVBAT_MOD23_T2

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 23, temperature 3 Q8_E_TRON_HVBAT_MOD23_T3

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 24, temperature 1 Q8_E_TRON_HVBAT_MOD24_T1

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 24, temperature 2 Q8_E_TRON_HVBAT_MOD24_T2

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 24, temperature 3 Q8_E_TRON_HVBAT_MOD24_T3

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 25, temperature 1 Q8_E_TRON_HVBAT_MOD25_T1

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 25, temperature 2 Q8_E_TRON_HVBAT_MOD25_T2

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 25, temperature 3 Q8_E_TRON_HVBAT_MOD25_T3

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 26, temperature 1 Q8_E_TRON_HVBAT_MOD26_T1

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 26, temperature 2 Q8_E_TRON_HVBAT_MOD26_T2

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 26, temperature 3 Q8_E_TRON_HVBAT_MOD26_T3

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 27, temperature 1 Q8_E_TRON_HVBAT_MOD27_T1

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 27, temperature 2 Q8_E_TRON_HVBAT_MOD27_T2

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 27, temperature 3 Q8_E_TRON_HVBAT_MOD27_T3

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 28, temperature 1 Q8_E_TRON_HVBAT_MOD28_T1

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 28, temperature 2 Q8_E_TRON_HVBAT_MOD28_T2

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 28, temperature 3 Q8_E_TRON_HVBAT_MOD28_T3

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 29, temperature 1 Q8_E_TRON_HVBAT_MOD29_T1

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 29, temperature 2 Q8_E_TRON_HVBAT_MOD29_T2

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 29, temperature 3 Q8_E_TRON_HVBAT_MOD29_T3

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 30, temperature 1 Q8_E_TRON_HVBAT_MOD30_T1

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 30, temperature 2 Q8_E_TRON_HVBAT_MOD30_T2

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 30, temperature 3 Q8_E_TRON_HVBAT_MOD30_T3

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 31, temperature 1 Q8_E_TRON_HVBAT_MOD31_T1

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 31, temperature 2 Q8_E_TRON_HVBAT_MOD31_T2

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 31, temperature 3 Q8_E_TRON_HVBAT_MOD31_T3

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 32, temperature 1 Q8_E_TRON_HVBAT_MOD32_T1

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 32, temperature 2 Q8_E_TRON_HVBAT_MOD32_T2

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 32, temperature 3 Q8_E_TRON_HVBAT_MOD32_T3

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 33, temperature 1 Q8_E_TRON_HVBAT_MOD33_T1

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 33, temperature 2 Q8_E_TRON_HVBAT_MOD33_T2

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Module 33, temperature 3 Q8_E_TRON_HVBAT_MOD33_T3

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Brakes

Brake disk drying active Q8_BRK_DRY_ACT

  • Service 22DID 180E
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2023, 2025. Not supported for 2024.

Brake disk drying last activation distance Q8_BRK_DRY_ODO_LAST

  • Service 22DID 180E
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Brake pressure Q8_BRK_PRESS

  • Service 22DID 1816
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

In testing for 2018 to 2023, 2025. Not supported for 2024.

Climate

Ambient temperature Q8_AATConfirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

0x0000 = 0 → 0128 = 0 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Outside temperature Q8_E_TRON_PTC_OUTSIDE_TConfirmed

  • Service 22DID 2609
  • Module742 → 7AC
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x94 = 148 → 1482−50 = 24 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Heater

Heater current Q8_E_TRON_PTC_HTR_I

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.74 A
Unit
A

In testing for 2018 to 2023, 2025. Not supported for 2024.

Heater fluid temperature #1 Q8_E_TRON_PTC_HTR_FLUID_T1

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Heater fluid temperature #2 Q8_E_TRON_PTC_HTR_FLUID_T2

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Clocks

Time since engine start Q8_E_TRON_TRON_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Control

Brake booster pressure Q8_BRAKE_BST_PConfirmed

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

0x0000 = 0 → 01000 = 0 bar

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Brake pressure Q8_E_TRON_TRON_BRAKE_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2018 to 2025.

Brake vacuum pump Q8_ENG_BRAKE_PUMPConfirmed

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Directional stability control active Q8_CSS_ACT

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2023, 2025. Not supported for 2024.

Directional stability control last activation distance Q8_CSS_ODO_LAST

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Directional stability control steering torque Q8_CSS_STR_TRQ

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

In testing for 2018 to 2023, 2025. Not supported for 2024.

Parking brake, air gap - left Q8_E_TRON_PARKING_BRAKE_AIR

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2018 to 2025.

Parking brake, air gap - right Q8_E_TRON_PARKING_BRAKE_AIR_GAP

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2018 to 2025.

Pressure in brake servo unit Q8_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2018 to 2025.

Steering wheel angle Q8_E_TRON_STEER_ANGLEConfirmed

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 2B29
  • Module713 → 77D
  • Every100 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 rad
Unit
rad

0x0000 = 0 → 01000 = 0 rad

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Pedals

Accelerator pedal position sensor 1 Q8_E_TRON_APP_POS1Confirmed

  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x02EF = 751 → 7511000 = 0.751 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Accelerator pedal position sensor 2 Q8_E_TRON_APP_POS2Confirmed

  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x0178 = 376 → 3761000 = 0.376 V

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Drivetrain

Driver torque requested #1 Q8_E_TRON_ENG_TRQ_REQ_1Confirmed

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Driver torque requested #2 Q8_ENG_TRQ_REQ_2Confirmed

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2024. In testing for 2018 to 2023, 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024.

Distance traveled since diagnostic trouble codes cleared Q8_E_TRON_TRON_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1568 = 5480 → 5,480 km

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Distance traveled while MIL was activated Q8_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Number of warm-ups since diagnostic trouble codes cleared Q8_E_TRON_TRON_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xBE = 190 → 190

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Engine

Air intake vacuum Q8_AIR_VAC

  • Service 22DID 1816
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

In testing for 2018 to 2023, 2025. Not supported for 2024.

Ambient air temperature Q8_E_TRON_TRON_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x7E = 126 → 1262−50 = 13 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Ambient air temperature, v1 Q8_AAT_V1Confirmed

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery management controller e temperature 1 Q8_E_TRON_BMS_BMCE_T1

  • Service 22DID 180C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Battery management controller e temperature 2 Q8_E_TRON_BMS_BMCE_T2

  • Service 22DID 180D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Battery management controller e temperature 3 Q8_E_TRON_BMS_BMCE_T3Confirmed

  • Service 22DID 180E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x01 = 1 → 1−50 = -49 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Battery management controller e temperature 4 Q8_E_TRON_BMS_BMCE_T_CAN

  • Service 22DID 1810
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Cabin temperature Q8_IAT

  • Service 22DID 2613
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Clutch 2 temperature Q8_E_TRON_TRON_PQ35_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Control module temperature Q8_E_TRON_TRON_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x015E = 350 → 35010 = 35 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Cooling inlet temperature Q8_E_TRON_BMS_COOL_IN_T

  • Service 22DID 181C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Cooling outlet temperature Q8_E_TRON_BMS_COOL_OUT_T

  • Service 22DID 181D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Differential pressure Q8_PQ35_DIFF_PConfirmed

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Elector motor 1 torque Q8_E_TRON_EM_TORQ_1Confirmed

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x0000 = 0 → 032 = 0 N·m

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Elector motor 2 torque Q8_E_TRON_EM_TORQ_2Confirmed

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x0000 = 0 → 032 = 0 N·m

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Elector motor 3 torque Q8_EM_TORQ_3Confirmed

  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Electric motor 1 rpm Q8_E_TRON_EM_RPM_1Confirmed

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-100 to 100 rpm
Unit
rpm

0x0000 = 0 → 02 = 0 rpm

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Electric motor 2 rpm Q8_EM_RPM_2Confirmed

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x7FFF = 32767 → 327672 = 16,383.5 rpm

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Electric motor non-vehicle power limitation Q8_HV_EM_NV_PWR_LIMITATION

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electric motor power limitation Q8_HV_EM_PWR_LIMITATION

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electric motor RPM Q8_E_TRON_ENG_MOTOR_RPMConfirmed

  • Service 22DID 3DF8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x0000 = 0 → 02 = 0 rpm

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Electronic differential lock active Q8_ELEC_DIFF_ACT

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electronic differential lock front left brake temperature Q8_ELEC_DIFF_FL_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electronic differential lock front right brake temperature Q8_ELEC_DIFF_FR_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electronic differential lock rear left brake temperature Q8_ELEC_DIFF_RL_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Electronic differential lock rear right brake temperature Q8_ELEC_DIFF_RR_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Engine torque limitation Q8_E_TRON_TRON_MQB_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2023, 2025. Not supported for 2024.

Exhaust gas temperature sensor 2 Q8_PQ35_EXHAUST_GAS_T_SENSOR_2Confirmed

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

0x0000 = 0 → 010−273.1 = -273.1 °C

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Generator current Q8_E_TRON_TRON_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2018 to 2025.

Hill descent control Q8_E_TRON_TRON_HDC_ACTIVEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Hill descent control, incline Q8_E_TRON_TRON_HDC_INCLINE

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2023, 2025

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2023, 2025. Supported for 2024.

Hydraulic brake booster active Q8_HYD_BRK_BST_ACT

  • Service 22DID 1810
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2023, 2025. Not supported for 2024.

Intake camshaft signal edge position adapted value edge 1 Q8_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1Confirmed

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

0x0000 = 0 → 016−32 = -32 °

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Oil thermal wear Q8_E_TRON_TRON_DASH_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Outside temperature Q8_E_TRON_TRON_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2018 to 2025.

Pressure supply actual pressure analog digital value Q8_E_TRON_TRON_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Shunt temperature Q8_E_TRON_BMS_SHUNT_T

  • Service 22DID 180F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2023, 2025. Not supported for 2024.

Water pump

Water pump power Q8_E_TRON_PTC_PUMP_PWRConfirmed

  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200
Unit
Raw value

0x00 = 0 → 0×40 = 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Water pump RPM Q8_E_TRON_PTC_PUMP_RPMConfirmed

  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×300
Range
0 to 76500 rpm
Unit
rpm

0x00 = 0 → 0×300 = 0 rpm

Confirmed for 2024. In testing for 2018 to 2023, 2025.

GPS

Satellites, tracked Q8_E_TRON_TRON_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Satellites, visible Q8_E_TRON_TRON_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Movement

Accelerator pedal position 1 Q8_E_TRON_TRON_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2025.

Accelerator pedal position 2 Q8_E_TRON_TRON_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2025.

Front left wheel speed Q8_FL_VSS_V2

  • Service 22DID 1800
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Front left wheel speed Q8_TIRE_FL_SPD

  • Service 22DID 2B1B
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Front left wheel speed Q8_TIRE_FL_SPD_7E1

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Front right wheel speed Q8_FR_VSS_V2

  • Service 22DID 1801
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Front right wheel speed Q8_TIRE_FR_SPD

  • Service 22DID 2B1C
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Rear left wheel speed Q8_RL_VSS_V2

  • Service 22DID 1802
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Rear left wheel speed Q8_TIRE_RL_SPD

  • Service 22DID 2B1D
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Rear right wheel speed Q8_RR_VSS_V2

  • Service 22DID 1803
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Rear right wheel speed Q8_TIRE_RR_SPD

  • Service 22DID 2B1E
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Vehicle speed Q8_E_TRON_TRON_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024.

Vehicle speed from transmission Q8_E_TRON_TRON_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2018 to 2023, 2025. Not supported for 2024.

Vehicle speed, directional Q8_E_TRON_VSS_DIRConfirmed

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 km/h
Unit
km/h

0x0000 = 0 → 064 = 0 km/h

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Stats

Launch control count Q8_E_TRON_LAUNCH

How many times you've initiated launch control on the car.

  • Service 22DID 5200
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000000
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tires

Front left wheel speed Q8_E_TRON_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2025.

Front right wheel speed Q8_E_TRON_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2025.

Rear left wheel speed Q8_E_TRON_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2025.

Rear right wheel speed Q8_E_TRON_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2025.

Steering wheel angle Q8_SWA_ALT

  • Service 22DID 1804
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.5625 °
Unit
°

In testing for 2018 to 2023, 2025. Not supported for 2024.

Steering wheel temperature Q8_E_TRON_TRON_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2025.

Tire pressure monitoring available Q8_TPMS_AVAIL

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring front left flat tire indicator Q8_TPMS_FL_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring front left tire leakage rate Q8_TPMS_FL_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring front right flat tire indicator Q8_TPMS_FR_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring front right tire leakage rate Q8_TPMS_FR_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading at fourth to last warning Q8_TPMS_ODO_WARN_4

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading at last adaptation Q8_TPMS_ODO_ADAPT_1

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading at last warning Q8_TPMS_ODO_WARN_1

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading at second to last warning Q8_TPMS_ODO_WARN_2

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading at third to last warning Q8_TPMS_ODO_WARN_3

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading four adaptations ago Q8_TPMS_ODO_ADAPT_4

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading three adaptations ago Q8_TPMS_ODO_ADAPT_3

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring odometer reading two adaptations ago Q8_TPMS_ODO_ADAPT_2

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring rear left flat tire indicator Q8_TPMS_RL_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring rear left tire leakage rate Q8_TPMS_RL_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring rear right flat tire indicator Q8_TPMS_RR_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Tire pressure monitoring rear right tire leakage rate Q8_TPMS_RR_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2023, 2025. Not supported for 2024.

Trips

Average consumption, category 0 Q8_E_TRON_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00DC = 220 → 22010 = 22 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 1 Q8_E_TRON_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00A0 = 160 → 16010 = 16 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 2 Q8_E_TRON_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0096 = 150 → 15010 = 15 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 3 Q8_E_TRON_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0096 = 150 → 15010 = 15 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 4 Q8_E_TRON_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 5 Q8_E_TRON_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B4 = 180 → 18010 = 18 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Average consumption, category 6 Q8_E_TRON_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Odometer Q8_E_TRON_TRON_MQB_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777175 km
Unit
km

In testing for 2018 to 2023, 2025. Supported for 2024.

Odometer Q8_ODO_714

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Odometer, mileage, HR Q8_E_TRON_TRON_ODO_MILEAGE_HR

Pelican can show this parameter as the odometer.

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2018 to 2025.

Range remaining, displayed Q8_RANGE_DSP

Pelican can show this parameter as the electric range.

  • Service 22DID 22E0
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2018 to 2023, 2025. Not supported for 2024.

Range remaining, unit unconfirmed Q8_E_TRON_RANGE_V2Confirmed

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2023, 2025

Example reply from a 2024 Audi Q8 e-tron.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x0065 = 101 → 101 mi

Confirmed for 2024. In testing for 2018 to 2023, 2025.

Trip consumption, short Q8_TRIP_USE_SHORT

Pelican can show this parameter as the traction battery efficiency.

  • Service 22DID 0530
  • Module714 → 77E
  • Every500 ms
  • Testing

Bits 238 to 255 of the reply, 18 bits. The value is signed.

Formula
val1000
Range
-131 to 131 kWh/100 mi
Unit
kWh/100 mi

In testing for 2018 to 2023, 2025. Not supported for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.