Audi S3

Parameters

The Audi S3 has 997 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage S3_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2191 = 8593 → 85931000 = 8.593 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery capacity S3_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal, sensor 1 voltage S3_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal, sensor 2 voltage S3_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

All-wheel drive voltage S3_PQ35_HAL_VConfirmed

  • Service 22DID 2BE9
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x00 = 0 → 010 = 0 V

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Aux. hydraulic pump voltage S3_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Battery acid stratification S3_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Battery condition for display S3_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Battery current filtered S3_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Battery internal resistance S3_SSB_RES_INTConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4
Unit
Number

0x17 = 23 → 235 = 4.6

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Battery internal resistance, raw S3_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Battery sensor temperature S3_BAT_TConfirmed

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x30 = 48 → 48−40 = 8 °C

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Battery voltage S3_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bypass valve high pressure turbine inlet, raw voltage S3_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge adjuster output stage S3_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value S3_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure S3_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Charge air pressure actuator position digit.value S3_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure actuator, acknowledgment S3_CHG_AIR_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure, actual value S3_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure, actual value S3_CHG_AIR_P_ACT

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure, specified value S3_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge air pressure: actual S3_PQ35_CHARGE_AIR_P_ACTUALConfirmed

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

0x03F3 = 1011 → 1011×0.08 = 80.88

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Charge air pressure: specified S3_PQ35_CHARGE_AIR_P_SPECIFIEDConfirmed

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

0x0316 = 790 → 790×0.08 = 63.2

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Charge pressure actuator, actual position S3_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure actuator, adaptation for lower stop S3_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure actuator, adaptation for upper stop S3_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure actuator, maximum sensor voltage S3_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure actuator, specified position S3_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure actuator, specified value S3_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure before throttle valve, calculated actual value S3_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control adaptation higher than max. threshold S3_CHG_P_CTRL_ADPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control adaptation lower than min. threshold S3_CHG_P_CTRL_ADPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control specified value S3_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve activation pulse duty factor S3_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve position, actual value S3_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve position, target value S3_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve sensor voltage S3_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve voltage, position closed S3_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure control valve voltage, position opened S3_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure regulator, lower threshold adaptation S3_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure regulator, upper threshold adaptation S3_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Charge pressure sensor, unconditioned voltage S3_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Control module voltage S3_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2191 = 8593 → 85931000 = 8.593 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Cylinder charge specified value S3_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder charge, actual value S3_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

DC to DC converter high-voltage side voltage S3_DCDC_HV_V

  • Service 22DID 1587
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

DC-DC converter, current S3_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2018.

DC-DC converter, low voltage S3_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x8F = 143 → 14310 = 14.3 V

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2018.

DC-DC converter, reserved current S3_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2018.

Generator voltage, actual S3_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High pressure exhaust gas recirculation actuator, actual unconditioned voltage S3_HIGH_P_EGR_ACTUATOR_ACT_V

  • Service 22DID 11A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High voltage battery energy information S3_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High voltage battery energy information S3_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

HV battery maximum power S3_HVBAT_PWR_MAX

  • Service 22DID 1502
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

HV battery temperature load S3_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage, cylinder 1 S3_KNOCK_SENS_V_CYL_1

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage, cylinder 3 S3_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage:, cylinder 2 S3_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage:, cylinder 3 S3_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage:, cylinder 5 S3_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor voltage:, cylinder 6 S3_KNOCK_SENS_V_CYL_6

  • Service 22DID 13FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensors average voltage bank 1, variant 2 S3_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Onboard electrical system power S3_AUX_PWR

  • Service 22DID 1077
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Start/stop battery charge S3_SSB_AHConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x00 = 0 → 0 Ah

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery current S3_SSB_CConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
0 to 100 A
Unit
A

0x00000000 = 0 → 01000 = 0 A

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery sensor temperature S3_SSB_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery state of charge S3_SSB_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery target voltage S3_SSB_VTConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

0x00 = 0 → 010+10.6 = 10.6 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery total charge S3_SSB_TOTAL_CHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 100 Ah
Unit
Ah

0x00000000 = 0 → 010 = 0 Ah

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery total discharge S3_SSB_TOTAL_DISCHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 100 Ah
Unit
Ah

0x00000000 = 0 → 010 = 0 Ah

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery voltage S3_SSB_VConfirmed

  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x0000 = 0 → 01000+4 = 4 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Start/stop battery voltage S3_SSB_V_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x1E = 30 → 3010+9 = 12 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Temperature sensor for engine temperature management voltage S3_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Turbocharger inlet pressure corrected value S3_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Climate

A/C compressor load S3_AC_COMPRESSOR_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x05 = 5 → 510 = 0.5 N·m

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

A/C compressor speed S3_AC_COMPRESSOR_SPEEDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Air pollution level S3_AIR_POLUTIONConfirmed

0 means clean air.

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.7 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Ambient air temperature S3_AATConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x60 = 96 → 962−50 = -2 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Ambient air temperature S3_AAT_7E0_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ambient temperature S3_AAT_V2Confirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

0x0000 = 0 → 0128 = 0 °C

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Barometric pressure S3_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cabin temperature S3_IAT_CABINConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x00B9 = 185 → 18510 = 18.5 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front left deflector temperature S3_FRONT_LEFT_DEFLECTOR_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x58 = 88 → 883 = 29.333333 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front left temperature flap actual value S3_FRONT_LEFT_T_FLAP_ACTUAL_VALUEConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x85 = 133 → 1332 = 66.5 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front right deflector temperature S3_FRONT_RIGHT_DEFLECTOR_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x57 = 87 → 873 = 29 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front right temperature flap actual value S3_FRONT_RIGHT_T_FLAP_ACTUAL_VALUEConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Leg deflector temperature S3_LEG_DEFLECTOR_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x4F = 79 → 793 = 26.333333 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Outside humidity S3_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016, 2018.

Outside temperature, from cabin S3_AAT_FROMCABINConfirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

0x60 = 96 → 962 = 48 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Radiator fan actual duty S3_RADIATOR_FAN_ACTUAL_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

0x19 = 25 → 25×0.4 = 10 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Radiator fan commanded duty S3_RADIATOR_FAN_COMMANDED_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×0.4 = 0 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Recirculation flap fresh air threshold S3_MQB_RECIRC_FLAP_FRESH_THRConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00B1 = 177 → 177

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Recirculation flap target position S3_MQB_RECIRC_FLAP_TRGConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00C8 = 200 → 200

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Recirculation flap threshold S3_MQB_RECIRC_FLAP_THRConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x035C = 860 → 860

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Recirculation flap, actual S3_MQB_RECIRC_FLAP_ACTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x7E = 126 → 1262 = 63 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Refrigerant pressure S3_REFRIGERANT_PRESSUREConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x00 = 0 → 05 = 0 bar

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Temperature after evaporator S3_T_AFTER_EVAPORATORConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val3
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Clocks

Time since engine start S3_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Control

Accelerator pedal release detection threshold voltage S3_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake booster low pressure, actual S3_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake booster pressure S3_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake booster pressure S3_PQ35_BRAKE_BOOSTER_PConfirmed

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

0x047E = 1150 → 11501000 = 1.15 bar

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Brake booster raw pressure S3_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake disk drying S3_BRAKE_DISK_DRYINGConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Brake pedal position S3_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake pressure S3_BRAKE_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake pressure S3_BRAKE_P_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Brake pressure sensor S3_BRAKE_PRESSURE_SENSORConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Brake system vacuum pump active S3_BRAKE_SYSTEM_VACUUMConfirmed

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Counter steer support S3_CSTEERConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Counter steer support, odometer S3_CSTEER_ODO_LAST_ACTIVATEDConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Counter steer support, steering torque S3_CSTEER_STEERING_TORQUEConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

0x0000 = 0 → 01000 = 0 N·m

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Distance since brake disk drying activated S3_BRAKE_DISK_DRYING_ODOConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x015112 = 86290 → 86,290 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Downshift point adaptation voltage S3_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Front left brake temperature S3_EDIFF_LOCK_FL_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front right brake temperature S3_EDIFF_LOCK_FR_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Parking brake, air gap - left S3_PARKING_BRAKE_AIR

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Parking brake, air gap - right S3_PARKING_BRAKE_AIR_GAP

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pressure in brake servo unit S3_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Rear left brake temperature S3_EDIFF_LOCK_RL_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear right brake temperature S3_EDIFF_LOCK_RR_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

0x0000 = 0 → 02 = 0 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Requested brake torque, auxiliary system S3_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pedals

Accelerator pedal position sensor 1 S3_APP_POS1Confirmed

  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x02EB = 747 → 7471000 = 0.747 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Accelerator pedal position sensor 2 S3_APP_POS2Confirmed

  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x0173 = 371 → 3711000 = 0.371 V

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Drivetrain

All-wheel drive current S3_PQ35_HAL_IConfirmed

  • Service 22DID 2BE6
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 A
Unit
A

0x0010 = 16 → 161000 = 0.016 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

All-wheel drive duty cycle S3_PQ35_HAL_DUTYConfirmed

  • Service 22DID 2BF3
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100.39255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100.39255 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

All-wheel drive mode S3_PQ35_HAL_MODEConfirmed

  • Service 22DID 0C0A
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

All-wheel drive pulse width modulation S3_PQ35_HAL_PWMConfirmed

  • Service 22DID 2BE7
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driver torque requested #1 S3_ENG_TRQ_REQ_1Confirmed

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Driver torque requested #2 S3_ENG_TRQ_REQ_2Confirmed

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016, 2018. Supported for 2017, 2019, 2022 to 2023.

Distance traveled since diagnostic trouble codes cleared S3_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0E53 = 3667 → 3,667 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Distance traveled while mil was activated S3_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Number of warm-ups since diagnostic trouble codes cleared S3_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x13 = 19 → 19

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

ECU

Oil thermal wear S3_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Engine

A/C compressor torque S3_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

A/C refrigerant pressure S3_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation of loss torque S3_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation of throttle valve S3_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder1 fast diagnosis S3_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder1 slow diagnosis S3_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder2 fast diagnosis S3_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder2 slow diagnosis S3_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder3 fast diagnosis S3_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder3 slow diagnosis S3_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder4 fast diagnosis S3_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation val.cylinder4 slow diagnosis S3_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptive mode S3_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air conditioning compressor pressure, linear raw value S3_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air conditioning compressor refrigerant pressure S3_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air conditioning compressor torque S3_AC_COMP_TQ

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air conditioning compressor torque S3_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air conditioning refrigerant pressure S3_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air filling S3_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air leakage S3_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air mass meter 1 S3_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026. Not supported for 2016.

Air mass, actual value, mg/stroke S3_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Air mass, specified value S3_AIR_MASS_SPEC

  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ambient air pressure S3_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ambient temperature S3_AAT_7E0

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ambient temperature S3_AAT_7E0_2

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 1, maximum temperature S3_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 2, maximum temperature S3_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Automatic engine starts counter S3_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Automatic transmission fluid temperature S3_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x03 = 3 → 3 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Aux. hydraulic pump internal temperature S3_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Aux. hydraulic pump, current S3_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Average ignition timing angle delay adjustment S3_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Avg. injection time S3_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Avg. injection time S3_AVG_INJ_TIME_7E0

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Basic correction factor:, cylinder 1, filtered S3_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Basic correction factor:, cylinder 2, filtered S3_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Basic correction factor:, cylinder 3, filtered S3_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Basic correction factor:, cylinder 4, filtered S3_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost pressure actuator, commanded duty S3_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost pressure, actual S3_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost pressure, actual S3_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost pressure, target S3_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost regulation duty, commanded value S3_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Boost regulator feedback S3_BOOST_REGULATOR_FEEDBACKConfirmed

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Bypass valve high pressure turbine inlet, activation S3_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bypass valve high pressure turbine inlet, actual value S3_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bypass valve high pressure turbine inlet, offset closed S3_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bypass valve high pressure turbine inlet, offset open S3_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bypass valve high pressure turbine inlet, target value S3_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bze_q_elad S3_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Bze_q_lad S3_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Calculated oil temperature S3_PQ35_CALCULATED_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Camshaft adaptation exhaust bank 1, phase position S3_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation intake bank 1, phase position S3_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation intake, phase position S3_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation, counter due to knock S3_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation, exhaust bank 1, phase position S3_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation, intake bank 1, phase position S3_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adaptation, intake deviation S3_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment intake bank 1, activation % S3_CAM_ADJ_INT_BANK_1

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment intake test bank 1 S3_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment outlet test bank 1 S3_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust bank 1, actual value S3_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust bank 1, specified value S3_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust bank 2, actual value S3_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust bank 2, specified value S3_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust, actual value S3_CAM_ADJ_EXH_ACT

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, exhaust, specified value S3_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, intake bank 1, actual value S3_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, intake bank 1, specified value S3_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, intake, actual value S3_CAM_ADJ_INT_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft adjustment, intake, specified value S3_CAM_ADJ_INT_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft position, deviation from the base position S3_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cat. converter oxygen storage capacity measured S3_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cat. temperature, bank 1 S3_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cat. temperature, bank 2 S3_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Catalyst temperature, calculated S3_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Centrifugal oil temperature S3_PQ35_CENTRIFUGAL_OIL_TConfirmed

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

0x10 = 16 → 16

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Chain elongation inlet, mileage at last adaptation S3_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Chain elongation outlet, mileage at last adaptation S3_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 S3_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Chain elongation, no of valid initial values, intake bank 1 S3_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch center central plate temperature S3_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Commanded crankshaft torque S3_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Compression test, cylinder 1 S3_COMPRESSION_TEST_CYL_1

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Compression test, cylinder 2 S3_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Compression test, cylinder 3 S3_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Compression test, cylinder 4 S3_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Control module temperature S3_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Control module temperature S3_MQB_TCM_ECU_TConfirmed

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x14 = 20 → 20 °C

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Converter loss torque S3_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x5000 = 20480 → 2048020 = 1,024 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Coolant circulation pump, activation S3_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant circulation pump, control S3_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant fan 1 activation, $1117 S3_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant fan 1, activation S3_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant fan 1, activation S3_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant fan 2, activation S3_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant fan, requested by A/C S3_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant shut-off valve, closed S3_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at engine outlet, calculated S3_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at engine outlet, calculated S3_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at engine start S3_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at engine start S3_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet S3_COOLANT_TConfirmed

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Coolant temperature at radiator outlet S3_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet 2 S3_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet v.1 S3_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet, actual value S3_ECT_RADIATOR_OUTLET_ACT

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet, actual value S3_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature at radiator outlet, specified value S3_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature difference between engine and radiator S3_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature linear S3_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2929710000000−48
Range
-48 to 143.9978 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature modeled value S3_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature, maximum value S3_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Coolant temperature, minimum value S3_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Correction factor of oil temperature for engine protection S3_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Correction values for main pressure adaptation S3_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPTConfirmed

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0089 = 137 → 137100 = 1.37 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Crankshaft rotation angle when closing the quantity control valve S3_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 S3_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 S3_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 S3_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current N215 pressure control valve 1 S3_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current N216 pressure control valve 2 S3_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current N217 pressure control valve 3 S3_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current N218 pressure control valve 4 S3_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current N233 pressure control valve 5 S3_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current solenoid S3_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current type of driver counter S3_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder 1 internal torque S3_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder 2 internal torque S3_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder 3 internal torque S3_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder 4 internal torque S3_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder block temperature sensor S3_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Cylinder head temperature S3_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Desired torque raw S3_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Diesel particulate filter exhaust gas flow volume S3_MQB_DPF_EXH_VOLConfirmed

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

0x4E4F = 20047 → 20047×100010000 = 2,004.7

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Diesel particulate filter surface temperature S3_DPF_SFC_TConfirmed

  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Direct injections counter S3_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Drive motor current S3_MOTOR_I

  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Drive motor speed S3_MOTOR_RPM_ECM

  • Service 22DID 149A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Drive motor torque S3_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Driver demand torque S3_MQB_TCM_DRIVER_DEMAND_TORQUEConfirmed

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0401 = 1025 → 102520 = 51.25 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving mode sensor, hall sensor a S3_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Driving position S3_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Driving resistance index S3_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Dynamic average of ignition angle delay adjustment S3_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ea888b boost pressure control, adaptation value 0 S3_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ea888b boost pressure control, adaptation value 1 S3_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ea888b boost pressure control, adaptation value 2 S3_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ea888b boost pressure control, adaptation value 3 S3_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ea888b boost pressure regulator, commanded S3_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for toque reduction, cylinder 1 S3_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for toque reduction, cylinder 2 S3_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for toque reduction, cylinder 3 S3_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for toque reduction, cylinder 4 S3_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder 1 S3_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder 2 S3_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder 3 S3_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder 4 S3_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 S3_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 S3_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 S3_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 S3_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 S3_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 S3_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 S3_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 S3_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, total, cylinder 1 S3_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, total, cylinder 2 S3_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, total, cylinder 3 S3_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter, total, cylinder 4 S3_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Effective injection duration S3_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

EGT after catalyst, model bank b S3_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Electric additional coolant pump control, high circle S3_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Energy balance of last driving cycle S3_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Energy content S3_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine air mass, specified value S3_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine compartment temperature raw value S3_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine control module temperature S3_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0082 = 130 → 13010 = 13 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Engine drag torque S3_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil level S3_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil level current value S3_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil pressure S3_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil sump temperature S3_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil temperature S3_EOTConfirmed

  • Service 22DID 202F
  • Module714 → 77E
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−58
Range
-58 to 197 °C
Unit
°C

0xA0 = 160 → 160−58 = 102 °C

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Engine oil temperature S3_EOT_7E0

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil temperature S3_EOT_7E0_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil temperature measured value S3_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil temperature sensor 2 S3_EOT_SENS_2

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine oil temperature, pulse sensor S3_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine outlet coolant temperature calculated S3_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine protection, torque limit S3_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine radiator fan request S3_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature control actuator S3_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature management actuator, after-run stop S3_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature management actuator, duty cycle activation S3_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature management actuator, raw value S3_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature management actuator, specified value S3_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine temperature management actuator, stop open S3_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque S3_ENG_TQ

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque S3_ENG_TQ_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque S3_ENG_TQ_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque S3_ENGINE_TORQUE

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque S3_MQB_TCM_ENGINE_TORQUEConfirmed

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0050 = 80 → 8020 = 4 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engine torque limitation S3_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine torque limitation S3_MQB_TCM_ENGINE_TORQUE_LIMITATIONConfirmed

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x1914 = 6420 → 642020 = 321 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engine torque loss S3_MQB_TCM_ENGINE_TORQUE_LOSSConfirmed

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0xFE20 = -480 → -48020 = -24 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Excessive temperature protection S3_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust camshaft, adaptation bias S3_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust camshaft, adaptation sensor tolerance S3_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas jet volume in particle filter S3_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature S3_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature - calculated after catalyst S3_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature before catalytic converter S3_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature before the front catalytic converter, model value S3_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 1 S3_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 1 S3_EXH_GAS_T_SENS_1_7E0

  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 1, bank 2 S3_EXH_GAS_T_SENS_1_2

  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 3 S3_EXH_GAS_T_SENS_3

  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 3, bank 2 S3_EXH_GAS_T_SENS_3_2

  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature sensor 4 S3_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust gas temperature, sensor 4, bank 2 S3_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Exhaust temperature before the catalyst, modeled S3_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator current S3_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator load normalized value S3_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator load signal S3_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator load signal S3_GEN_LOAD_SIG_7E0

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator load signal S3_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator performance S3_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Generator torque request S3_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Heater circulation pump, nominal value S3_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Heater support pump, specified value S3_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Height correction S3_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High pressure control, adaptation S3_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High pressure EGR actuator, activation S3_HIGH_P_EGR_ACTUATOR

  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High pressure regulation, adaptation value S3_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

ID of current driving program S3_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_CYL_KNK, 0 S3_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_CYL_KNK, 1 S3_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_CYL_KNK, 2 S3_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_CYL_KNK, 3 S3_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_IGC, 0 S3_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_IGC, 1 S3_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_IGC, 2 S3_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

IGA_IGC, 3 S3_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ignition angle current cylinder, actual value S3_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ignition timing angle retard, cylinder 4 S3_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 1 S3_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 2 S3_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 2 S3_INJ_AMOUNT_DEV_CYL_2_7E0

  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 3 S3_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 4 S3_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection amount deviation cylinder 5 S3_INJ_AMOUNT_DEV_CYL_5

  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection quantity deviation, cylinder 2 S3_INJ_QTY_DEV_CYL_2

  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection quantity deviation, cylinder 5 S3_INJ_QTY_DEV_CYL_5

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 2, rail pressure calibration point 1 S3_INJ_2_RAIL_P_1

  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 2, rail pressure calibration point 2 S3_INJ_2_RAIL_P_2

  • Service 22DID 10DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 2: rail pressure calibration point 1 S3_INJ_2_RAIL_P_CAL_PT_1_146EConfirmed

  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x0000 = 0 → 020 = 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Injector 2: rail pressure calibration point 2 S3_INJ_2_RAIL_P_CAL_PT_2_1474Confirmed

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x0000 = 0 → 020 = 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Injector 2: rail pressure calibration point 3 S3_INJ_2_RAIL_P_CAL_PT_3_147AConfirmed

  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x0000 = 0 → 020 = 0

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Injector 4, rail pressure calibration point 2 S3_INJ_4_RAIL_P_2

  • Service 22DID 10D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 5, rail pressure calibration point 2 S3_INJ_5_RAIL_P_2

  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 5, rail pressure calibration point 3 S3_INJ_5_RAIL_P_3

  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injector 7: rail pressure calibration point 1 S3_INJ_7_RAIL_P_CAL_PT_1Confirmed

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x000C = 12 → 1220 = 0.6

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Injector 7: rail pressure calibration point 2 S3_INJ_7_RAIL_P_CAL_PT_2Confirmed

  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x0000 = 0 → 020 = 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Injector 7: rail pressure calibration point 3 S3_INJ_7_RAIL_P_CAL_PT_3Confirmed

  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

0x0000 = 0 → 020 = 0

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Inlet flaps - actual value S3_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Inlet flaps - requested value S3_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake air temperature S3_IAT_7E0Confirmed

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x5F = 95 → 95×34−48 = 23.25 °C

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026.

Intake air temperature before throttle valve, raw value S3_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake air temperature in intake manifold S3_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake air temperature raw value S3_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake camshaft, adaptation bias S3_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake camshaft, adaptation sensor tolerance S3_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake manifold pressure raw value S3_INT_MANIFOLD_P_RAW

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake manifold pressure, commanded S3_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake manifold pressure, corrected S3_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake manifold runner control, acknowledgment S3_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake manifold runner control, activation S3_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake model air mass flow filtered value S3_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Intake phase deviation, actual value S3_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Integrated mass of air since engine start S3_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Integrated mass of air since the first engine start S3_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Kick down S3_MQB_TCM_KICK_DOWNConfirmed

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Kilometers driven since last event on K1 S3_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

0x0001 = 1 → 1×10 = 10 km

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Kilometers driven since last event on K2 S3_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

0x0001 = 1 → 1×10 = 10 km

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Knock retard 2 S3_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock retard 4 S3_KNOCK_RETARD_4

  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor 1 test S3_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor 2 test S3_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor 3 test S3_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor 4 test S3_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 1 S3_KNOCK_SENS_CYL_1

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 1 S3_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 2 S3_KNOCK_SENS_CYL_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 2 S3_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 2 S3_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 3 S3_KNOCK_SENS_CYL_3

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 3 S3_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 4 S3_KNOCK_SENS_CYL_4

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Knock sensor, cylinder 4 S3_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lambda output value S3_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lambda, actual value S3_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Launch control counter, variant 1 S3_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Launch control counter, variant 2 S3_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim at idle, direct injection S3_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim at idle, port injection S3_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long-term adaptation of intake manifold injection S3_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long-term adaptation of intake manifold injection at idle S3_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lost torque adaptation A/C + driving mode S3_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lost torque adaptation driving mode S3_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Low pressure EGR closing S3_LOW_P_EGR_CLOSING

  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-252048+100
Range
-699 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation S3_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2A = 42 → 42×5 = 210 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

M009, desired solenoid out 10 S3_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

M009, desired solenoid out 11 S3_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

M009, desired solenoid out 12 S3_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

M009, desired solenoid out 13 S3_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

M009, desired solenoid out 14 S3_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Main cat oxygen storage capacity age correction factor S3_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Manifold absolute pressure, raw value S3_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Manual engine starts counter S3_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mass air flow over throttle valve S3_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mass air flow rate S3_MAF_RATE

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mass air flow through throttle S3_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mass air flow, commanded S3_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mass flow through throttle valve S3_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Max permissible engine torque S3_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Maximum ECU temperature S3_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Maximum filling correction factor from knock control S3_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Maximum oil level for the service interval S3_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mean engine air mass S3_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mean injection quantity S3_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mean injection quantity S3_MEAN_INJ_QUANTITYConfirmed

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

0xE8CF = -5937 → -5937100 = -59.37

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Mileage with ECU installed S3_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Minimum oil level for the service interval S3_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires counter:, cylinder 1 S3_MIS_CNT_1

  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires counter:, cylinder 2 S3_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires counter:, cylinder 3 S3_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires counter:, cylinder 5 S3_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires counter:, cylinder 6 S3_MIS_CNT_6

  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions 2 S3_MIS_PER_1000_2_7E0_7E0

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions 4 S3_MIS_PER_1000_REVOLUTIONS_4_7E0

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection S3_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 2 S3_MIS_PER_1000_2_7E0

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection S3_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 3 S3_MIS_PER_1000_3_7E0

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection S3_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection S3_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires total S3_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 1 S3_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 1 S3_MISFIRES_C1_7E0

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 2 S3_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 2 S3_MISFIRES_C2

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 3 S3_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 3 S3_MISFIRES_C3_7E0

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 4 S3_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires, cylinder 4 S3_MISFIRES_C4

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mixture adaptation factor at partial load S3_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

N_32 S3_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

NL_PRE, 0 S3_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

NL_PRE, 1 S3_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

NL_PRE, 2 S3_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

NL_PRE, 3 S3_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Number of injections S3_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded S3_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Number of warnings due to increased centrifugal oil temperature S3_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

NV energy requirement S3_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil ash limit S3_OIL_ASH_LIM

  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil ash residue S3_OIL_ASH_RESIDUE

  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×3.052e-7
Range
0 to 1310
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil fill level S3_PQ35_OIL_FILL_LEVELConfirmed

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

0x0006 = 6 → 6×0.06 = 0.36 mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Oil level method 1 S3_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level method 2 S3_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level method 3 S3_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level test method 1 S3_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level test method 2 S3_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level test method 3 S3_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level, average dynamic value S3_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level, last valid dynamic value S3_OIL_LEVEL_LAST_VALIDConfirmed

  • Service 22DID 10F3
  • Module7E0
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

0x0F66 = 3942 → 394216−127 = 119.375 mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Oil level, static measured S3_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil level, static measurement S3_OIL_LEVEL_STATIC_7E0

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil p S3_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure actual current S3_MQB_TCM_EOP_ACTUAL_IConfirmed

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Oil pressure control valve activation pulse duty factor S3_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure control valve, activation pulse duty factor S3_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure sensor raw value S3_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status S3_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure sensor, raw value S3_OIL_P_SENS_RAW_7E0

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure switch activation, high pressure S3_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure switch for high pressure, closed S3_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure switch for low pressure, closed S3_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure switch for piston-cooling jets, closed S3_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure switch valve activation S3_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure target S3_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure target S3_OIL_P_TGT_7E0

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio S3_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure valve switch, control S3_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure, actual value S3_OIL_P_ACT_7E0

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure, actual value S3_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil pressure, actual value S3_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil temperature S3_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oil warning threshold S3_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Open cam shaft angle at quantity control valve S3_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Outside temperature S3_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Outside temperature, system calculated S3_OUTSIDE_T_SYSTEMConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x5D = 93 → 932−50 = -3.5 °C

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Overall energy balance S3_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oxygen control, adaptation value at part. load S3_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature S3_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Particle sensor, time in op.mode measurement S3_PARTICLE_SENS_TIME

  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pilot injection 1, activation start S3_PRE_INJ_1_ACTIVATION

  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pilot injection 2, activation start S3_PRE_INJ_2_ACTIVATION

  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pilot injection 3 start S3_PRE_INJ_3_START

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219731000000
Range
-720 to 719 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pilot injection 3, activation duration S3_PRE_INJ_3_ACTIVATION

  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pilot injection 3, activation start S3_PRE_INJ_3_ACTIVATION_START

  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Piston cooling nozzles, control S3_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Piston-cooling jets, activation S3_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Port injection injections counter S3_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 1 S3_POST_INJ_1

  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 1 S3_POST_INJ_1_7E0

  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 2 S3_POST_INJ_2

  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 2 S3_POST_INJ_2_7E0_7E0

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 3 S3_POST_INJ_3

  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post injection 3 S3_POST_INJ_3_7E0

  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Post-injection 1 duration S3_PQ35_POST_INJ_1_DURATION

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026. Not supported for 2016.

Post-injection 2, activation duration S3_POST_INJ_2_7E0

  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pressure before throttle valve - actual value S3_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pressure before throttle valve - sensor measured S3_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 S3_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 S3_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 S3_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Radiator fan 1, commanded duty S3_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Radiator fan 2, commanded duty S3_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Rated drive torque S3_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Reached maximum temperature S3_PQ35_REACHED_MAXIMUM_TConfirmed

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0072 = 114 → 114 °C

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Rear cat converter temperature, main catalytic converter model value S3_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Reducing agent tank volume, act. value filtered S3_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Relative load value S3_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Relay for reserve coolant pump status S3_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Requested torque, amount for auxiliary units S3_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Reserve torque S3_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Result of crankcase ventilation test, fail S3_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Result of crankcase ventilation test, successful S3_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Route data, active S3_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Secondary air injection sensor 1 S3_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_H, 0 S3_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_H, 2 S3_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_H, 3 S3_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_L, 0 S3_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_L, 2 S3_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_L, 3 S3_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_MID, 0 S3_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_MID, 1 S3_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER_MID, 2 S3_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER, 1 S3_SEG_AD_MMV_ER_1

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER, 2 S3_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

SEG_AD_MMV_ER, 3 S3_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Sensor for particle filter differential pressure, raw value S3_SENS_PARTICLE_FLT_P

  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Service limit S3_SERVICE_LIM

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Service limit S3_SERVICE_LIM_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

SIM card, SIM card in main unit S3_SIM_CARD_SIM_CARD

  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Spark efficiency deviation at idle, maximum S3_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Spark efficiency deviation at part load, maximum S3_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Stop signal switch S3_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Sum of misfires counter S3_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Tank fill level diagnostic reference value S3_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TCO_1_ST S3_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TCO_1_SYS S3_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Temperature at air conditioner heat exchanger output S3_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Temperature sensor for engine temperature management S3_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Temperature sensor for engine temperature management, target value S3_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Test of catalytic converter status, canceled S3_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Test of catalytic converter, measured value S3_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Thermostat, actual S3_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Thermostat, commanded S3_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Throttle regulator nominal value S3_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_1_MPI, 0 S3_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_1_MPI, 1 S3_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_1_MPI, 2 S3_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_1_MPI, 3 S3_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_1, 1 S3_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_1, 2 S3_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_1, 3 S3_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_2, 0 S3_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_2, 1 S3_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_2, 2 S3_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_2, 3 S3_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_3, 0 S3_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_3, 1 S3_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_3, 2 S3_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

TI_MES4_PLS_3, 3 S3_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Time in after-run S3_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Time since reset S3_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing angle retardation cylinder 1 S3_PQ35_TIMING_ANGLE_RETARDATION_CYL_1Confirmed

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

0x00 = 0 → 0×0.375−48 = -48 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Timing angle retardation cylinder 2 S3_PQ35_TIMING_ANGLE_RETARDATION_CYL_2Confirmed

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

0x00 = 0 → 0×0.375−48 = -48 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Timing angle retardation cylinder 3 S3_PQ35_TIMING_ANGLE_RETARDATION_CYL_3Confirmed

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

0x00 = 0 → 0×0.375−48 = -48 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Timing angle retardation cylinder 4 S3_PQ35_TIMING_ANGLE_RETARDATION_CYL_4Confirmed

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

0x00 = 0 → 0×0.375−48 = -48 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Timing deviation after chain replacement, exhaust bank 1 S3_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing deviation after chain replacement, intake bank 1 S3_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing deviation after other repairs, intake bank 1 S3_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing deviation after other repairs, intake bank 1 S3_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing deviation current value exhaust bank 1 S3_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Timing deviation current value intake bank 1 S3_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter: torque loss S3_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque factor S3_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque increase request from ESP S3_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque limitation S3_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque limitation S3_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque limitation S3_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque limitation, clutch protection S3_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque loss adaptation S3_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque loss adaptation at idle S3_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque loss adaptation, A/C compressor S3_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque reduction request from ESP S3_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque request, sum of auxiliary aggregate S3_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque transmitting function, ratio S3_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Total mass of gasoline and ethyl alcohol in oil S3_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission drag torque S3_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission fluid temperature, calculated S3_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission fluid temperature, modeled maximum reached S3_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission torque losses S3_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Turbine actuator 1 bank 1 activation S3_PQ35_TURB_ACT_1_B1Confirmed

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x001C = 28 → 28100 = 0.28 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Turbine actuator 1 bank 1: activation S3_ACTConfirmed

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation S3_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xB4 = 180 → 180×5 = 900 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation S3_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xA5 = 165 → 165×5 = 825 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Valve lift system, result of last switch, intake S3_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Valve lift system, valve lift, exhaust S3_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Valve lift system, valve lift, intake S3_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Valve timing, the difference between the, actual and the set angle S3_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Variable valve timing, intake, bank 1, regulation S3_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Variable valve timing, intake, bank 1, switch on S3_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Washer nozzle heater active S3_MQB_HTR_NOZZLEConfirmed

  • Service 22DID 1945
  • Module70E → 778
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Wear index %, 0=new engine S3_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016. Supported for 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2016. Supported for 2018.

Fuel

Activation of fuel pump electronics S3_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Counter of fuel entry in oil S3_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Error counter bad fuel S3_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel consumption S3_FUEL_CONSConfirmed

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0xE910 = 59664 → 59664100 = 596.64 L

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Fuel consumption - actual drive cycle S3_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel consumption per driving cycle S3_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel flow S3_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel high pressure, actual value S3_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel high pressure, control deviation S3_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel high pressure, specified value S3_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel injector time deviation, cylinder 1 S3_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel injector time deviation, cylinder 2 S3_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel injector time deviation, cylinder 2 S3_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel injector time deviation, cylinder 3 S3_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel injector time deviation, cylinder 4 S3_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel level S3_FLI_7E0

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel level input % S3_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel low pressure, actual value S3_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel low pressure, specified value S3_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel mass request, integral controller S3_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel mass request, proportional controller S3_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel metering valve S3_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel mix correction coefficient S3_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel part from EVAP system S3_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel pressure regulator valve: specified value rail pressure S3_SPEC_VALUE_RAIL_PConfirmed

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

0x0B6C = 2924 → 2924×100 = 292,400

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Fuel pressure, low actual S3_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel pump adaptation S3_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel pump specified value S3_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel pump, commanded duty S3_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel rate S3_FUEL_RATE

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel rate difference, injector/sensor S3_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel tank fill level S3_FUEL_TANK_FILL_LEVEL

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel temperature S3_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel temperature S3_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel temperature S3_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fuel volume S3_FLI_VOL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 22B0
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016, 2018.

High fuel pressure control deviation S3_HIGH_FUEL_P_CONTROL_DEVIATIONConfirmed

  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

0x18B7 = 6327 → 6327×100 = 632,700

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

High fuel pressure, actual S3_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High fuel pressure, actual value S3_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High fuel pressure, commanded S3_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High fuel pressure, regulation error S3_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

High fuel pressure, target S3_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim at idle S3_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim at idle S3_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim bank 1 S3_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim direct injection at load S3_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Long term fuel trim port injection at load S3_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Low fuel pressure, actual S3_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Low fuel pressure, commanded S3_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual S3_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum S3_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Short term fuel trim bank 1 S3_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Movement

Acceleration S3_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Acceleration S3_ACCEL_7E0

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Acceleration S3_ACCELERATIONConfirmed

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

0x0001 = 1 → 11000 = 0.001 m/s²

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Acceleration S3_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Acceleration or deceleration mode S3_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal limit S3_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026. Not supported for 2016.

Accelerator pedal position S3_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal position S3_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal position 1 S3_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal position 2 S3_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Accelerator pedal torque limit S3_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

All-wheel drive front-rear speed differential S3_PQ35_HAL_F_R_VSS_DIFFConfirmed

  • Service 22DID 2BF0
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Aux. hydraulic pump RPM S3_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft speed S3_CAM_SPD

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Camshaft speed S3_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Compressor speed S3_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Crankshaft speed S3_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Crankshaft speed, RPM S3_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine RPM S3_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engine RPM at idle required S3_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Front left wheel speed S3_PQ35_FL_VSSConfirmed

  • Service 22DID 2B1B
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Front left wheel speed S3_TIRE_FL_SPD_V3

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016, 2018.

Front right wheel speed S3_PQ35_FR_VSSConfirmed

  • Service 22DID 2B1C
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Front right wheel speed S3_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Idle speed specified rpm S3_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection speed injector 0 S3_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection speed injector 1 S3_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection speed injector 2 S3_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Injection speed injector 3 S3_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Input shaft speed 1 S3_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Input shaft speed 2 S3_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lateral acceleration S3_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Longitudinal acceleration S3_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Longitudinal acceleration, raw S3_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm, all cylinders S3_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm:, cylinder 1 S3_MIS_PER_1000_RPM_1

  • Service 22DID 1484
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm:, cylinder 3 S3_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm:, cylinder 4 S3_MIS_PER_1000_RPM_4

  • Service 22DID 1485
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm:, cylinder 5 S3_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires per 1000 rpm:, cylinder 6 S3_MIS_PER_1000_RPM_6

  • Service 22DID 1487
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires/1000 rpm, cylinder 1 S3_MISFIRES_1000_RPM_C1

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires/1000 rpm, cylinder 2 S3_MISFIRES_1000_RPM_C2

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires/1000 rpm, cylinder 3 S3_MISFIRES_1000_RPM_C3

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Misfires/1000 rpm, cylinder 4 S3_MISFIRES_1000_RPM_C4

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mixture adaptation factor at idle speed S3_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Rear left wheel speed S3_PQ35_RL_VSSConfirmed

  • Service 22DID 2B1D
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Rear left wheel speed S3_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0100 = 256 → 25610 = 25.6 km/h

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Rear right wheel speed S3_PQ35_RR_VSSConfirmed

  • Service 22DID 2B1E
  • Module70F → 779
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Rear right wheel speed S3_TIRE_RR_SPD_V3

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Supported for 2018. Not supported for 2016.

Reducing agent pump, differential speed calculated S3_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Specified idle RPM S3_MQB_DQ250_SPECIFIED_IDLE_RPMConfirmed

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0258 = 600 → 600 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Speed ​​output S3_MQB_DQ250_SPD_OUTPUTConfirmed

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Transmission input speed S3_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380AConfirmed

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Transmission output speed S3_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380BConfirmed

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Vehicle lateral acceleration, raw value S3_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Vehicle speed S3_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Vehicle speed S3_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Vehicle speed ESP S3_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Vehicle speed from transmission S3_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSIONConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Vehicle speed, HR S3_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Yaw acceleration, raw value S3_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2016. Supported for 2017 to 2019, 2022 to 2023.

Orientation

Hill descent control S3_HDC_ACTIVEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Hill descent control, incline S3_HDC_INCLINEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Tires

Air gab vacuum sensor S3_AIR_GAB_VACUUM_SENSORConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Electronic differential lock: active S3_EDIFF_LOCK_ACTIVEConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Entire energy throughput S3_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Front left flat tire flat? S3_TPMS_FL_FLAT_TIREConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xEB = 235 → 235

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front left tire pressure diffusion S3_TPMS_FL_TP_DIFFUSIONConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC6 = 198 → 198

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front left wheel speed S3_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Front right flat tire flat? S3_TPMS_FR_FLAT_TIREConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xEB = 235 → 235

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front right tire pressure diffusion S3_TPMS_FR_TP_DIFFUSIONConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC6 = 198 → 198

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Front right wheel speed S3_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Hydraulic brake booster S3_HYDR_BRAKEBOOSTConfirmed

  • Service 22DID 1810
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, four adaptations ago S3_TPMS_ODO_FOUR_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000D5ED = 54765 → 54,765 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, fourth-to-last warning S3_TPMS_ODO_FOURTH_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000C853 = 51283 → 51,283 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, last adaptation S3_TPMS_ODO_LAST_ADAPTATIONConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00013ED2 = 81618 → 81,618 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, last warning S3_TPMS_ODO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x00013ECB = 81611 → 81,611 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, next-to-last warning S3_TPMS_ODO_NEXT_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x000120CA = 73930 → 73,930 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, third-to-last warning S3_TPMS_ODO_THIRD_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000FEA5 = 65189 → 65,189 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, three adaptations ago S3_TPMS_ODO_THREE_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000FED0 = 65232 → 65,232 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer, two adaptations ago S3_TPMS_ODO_TWO_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x000120CA = 73930 → 73,930 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear left flat tire flat? S3_TPMS_RL_FLAT_TIREConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xEB = 235 → 235

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear left tire pressure diffusion S3_TPMS_RL_TP_DIFFUSIONConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC6 = 198 → 198

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear left wheel speed S3_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Rear right flat tire flat?r S3_TPMS_RR_FLAT_TIREConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xEB = 235 → 235

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear right tire pressure diffusion S3_TPMS_RR_TP_DIFFUSIONConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC6 = 198 → 198

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Rear right wheel speed S3_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Steering wheel angle S3_STEER_WHEEL_ANGLEConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 °
Unit
°

0x002F = 47 → 478 = 5.875 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Steering wheel angle S3_STEER_WHEEL_ANGLE_ABSConfirmed

  • Service 22DID 1804
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.5625 °
Unit
°

0x0146 = 326 → 326×0.4375 = 142.625 °

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Steering wheel temperature S3_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Steering wheel torque sensor 1 S3_STEER_WHL_TQ_SENS_1

  • Service 22DID 1805
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Steering wheel torque sensor 2 S3_STEER_WHL_TQ_SENS_2

  • Service 22DID 1806
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Tire pressure monitoring system available S3_TPMSConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Transmission

Actual position of gear positioner a S3_MQB_DQ250_ACUTAL_POS_GEAR_POSER_AConfirmed

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Actual position of gear positioner b S3_MQB_DQ250_ACUTAL_POS_GEAR_POSER_BConfirmed

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Actual position of gear positioner c S3_MQB_DQ250_ACUTAL_POS_GEAR_POSER_CConfirmed

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Actual position of gear positioner d S3_MQB_DQ250_ACUTAL_POS_GEAR_POSER_DConfirmed

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0352 = 850 → 850×10010000 = 8.5 mm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Adaptation counter PF lockup clutch S3_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, clutch a S3_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, clutch b S3_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, clutch c S3_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, clutch d S3_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, clutch e S3_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, fast fill time, clutch a S3_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, fast fill time, clutch b S3_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, fast fill time, clutch c S3_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, fast fill time, clutch d S3_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, fast fill time, clutch e S3_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation counter, torque converter lockup clutch S3_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation fill time, torque converter lockup clutch S3_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Adaptation inflation current PF lockup clutch S3_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

All-wheel drive clutch blockage degree S3_MQB_HAL_CLUTCH_BLOCKConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bit 15 of the reply.

Formula
val×8
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0×8 = 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

All-wheel drive clutch fully open S3_MQB_HAL_CLUTCH_OPENConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 actual pressure S3_PQ35_CLUTCH_1_ACTUAL_PConfirmed

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 actual pressure raw value S3_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUEConfirmed

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x32 = 50 → 5010−1 = 4 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 failed adaptations counter S3_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 lower adaptation point S3_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 1 nominal pressure S3_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 1 successful adaptations counter S3_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1453 = 5203 → 5,203

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 upper adaptation point S3_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 1 valve current: actual S3_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUALConfirmed

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 1 valve current: specified S3_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 2 actual pressure S3_PQ35_CLUTCH_2_ACTUAL_PConfirmed

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x000F = 15 → 15100 = 0.15 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 2 failed adaptations counter S3_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 2 lower adaptation point S3_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 2 successful adaptations counter S3_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0E0C = 3596 → 3,596

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 2 upper adaptation point S3_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 2 valve current: actual S3_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUALConfirmed

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch 2 valve current: specified S3_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x0000 = 0 → 010 = 0 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch adaptation values initial kill point 0 for K1 S3_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1Confirmed

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x34 = 52 → 52×5 = 260 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch adaptation values initial kill point 0 for K2 S3_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2Confirmed

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2E = 46 → 46×5 = 230 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch adaptation values lower current point adaptation K1 S3_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1Confirmed

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2D = 45 → 45×5 = 225 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch adaptation values lower current point adaptation K2 S3_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2Confirmed

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x28 = 40 → 40×5 = 200 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Clutch overheating, clutch S3_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch temperature S3_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Correction values for main press adaptation: high press on clutch 1 S3_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0075 = 117 → 117100 = 1.17 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Correction values for main press adaptation: low press on clutch 1 S3_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0087 = 135 → 135100 = 1.35 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 S3_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0069 = 105 → 105100 = 1.05 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 S3_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0082 = 130 → 130100 = 1.3 bar

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Current gear S3_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current gear S3_MQB_TCM_I_GEAR_DQ200Confirmed

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

0x00 = 0 → 0−2 = -2

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation S3_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2D = 45 → 45×5 = 225 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation S3_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x28 = 40 → 40×5 = 200 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Current N371 pressure control valve 6 lock-up clutch S3_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation S3_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xC8 = 200 → 200×5 = 1,000 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation S3_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xC8 = 200 → 200×5 = 1,000 mA

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving strategy mountain factor S3_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTORConfirmed

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving strategy sport factor S3_PQ35_DRIVING_STRATEGY_SPORT_FACTORConfirmed

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×1700255 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Dynamic shift program S3_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for oxygen shift, cylinder 1 S3_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for oxygen shift, cylinder 2 S3_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for oxygen shift, cylinder 3 S3_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Early ignition counter for oxygen shift, cylinder 4 S3_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Engaged position side a gear selector 1-3 S3_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side a gear selector 2-4 S3_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side a gear selector 5 and neutral S3_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side a gear selector 6 and reverse S3_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side b gear selector 1-3 S3_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side b gear selector 2-4 S3_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side b gear selector 5 and neutral S3_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engaged position side b gear selector 6 and reverse S3_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Engine specified torque during transmission intervention S3_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fast fill time, clutch a S3_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fast fill time, clutch b S3_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fast fill time, clutch c S3_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fast fill time, clutch d S3_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fast fill time, clutch e S3_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fill pressure, clutch a S3_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fill pressure, clutch b S3_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fill pressure, clutch c S3_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fill pressure, clutch d S3_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Fill pressure, clutch e S3_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Gear S3_GEAR_V2Confirmed

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G1 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1Confirmed

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x155D = 5469 → 5469100 = 54.69 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G2 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2Confirmed

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x11D4 = 4564 → 4564100 = 45.64 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G3 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3Confirmed

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x117E = 4478 → 4478100 = 44.78 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G4 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4Confirmed

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x155A = 5466 → 5466100 = 54.66 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G5 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5Confirmed

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x14DF = 5343 → 5343100 = 53.43 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position G6 S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6Confirmed

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x14D6 = 5334 → 5334100 = 53.34 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Gear selector synchronous position, reverse S3_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_RConfirmed

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x11D7 = 4567 → 4567100 = 45.67 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Input shaft 1 S3_MQB_INPUT_SHAFT_1Confirmed

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Input shaft 2 S3_MQB_INPUT_SHAFT_2Confirmed

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Launch control counter, clutch 1 S3_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Load shift flaps, actual value S3_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Load shift flaps, specified value S3_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation S3_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPTConfirmed

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0x34 = 52 → 52200 = 0.26 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation S3_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPTConfirmed

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0x2E = 46 → 46200 = 0.23 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Mileage of oxidation catalytic converter S3_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Mileage of SCR catalytic converter S3_MILEAGE_SCR

  • Service 22DID 519E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Neutral position gear selector 1-3 S3_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1376 = 4982 → 4982×10010000 = 49.82 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Neutral position gear selector 2-4 S3_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x139B = 5019 → 5019×10010000 = 50.19 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Neutral position gear selector 5 and neutral S3_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1371 = 4977 → 4977×10010000 = 49.77 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Neutral position gear selector 6 and reverse S3_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1381 = 4993 → 4993×10010000 = 49.93 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Nominal pressure clutch 2 S3_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Output shaft 1 S3_MQB_OUTPUT_SHAFT_1Confirmed

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Output shaft 2 S3_MQB_OUTPUT_SHAFT_2Confirmed

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Powertrain overall gear ratio S3_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pressure_clutch_1 S3_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Pressure_clutch_2 S3_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Road resistance S3_PQ35_ROAD_RESISTANCEConfirmed

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

0x7F = 127 → 127×24.9100−31.6 = 0.023 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Selected gear S3_SELECTED_GEAR

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Shift process, selected gear S3_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Shift process, target gear S3_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Specified torque clutch 1 S3_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1Confirmed

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Specified torque clutch 1 - data S3_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Specified torque clutch 2 S3_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2Confirmed

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

0x070D = 1805 → 1805×5100 = 90.25 N·m

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Specified torque clutch 2 - data S3_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Synchronous position side a gear selector 1-3 S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x117E = 4478 → 4478×10010000 = 44.78 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side a gear selector 2-4 S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x11D4 = 4564 → 4564×10010000 = 45.64 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side a gear selector 5 and neutral S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x124D = 4685 → 4685×10010000 = 46.85 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side a gear selector 6 and reverse S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x11D7 = 4567 → 4567×10010000 = 45.67 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side b gear selector 1-3 S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x155D = 5469 → 5469×10010000 = 54.69 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side b gear selector 2-4 S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x155A = 5466 → 5466×10010000 = 54.66 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side b gear selector 5 and neutral S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x14DF = 5343 → 5343×10010000 = 53.43 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Synchronous position side b gear selector 6 and reverse S3_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x14D6 = 5334 → 5334×10010000 = 53.34 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Time since shift S3_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter amplification S3_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque loss adaptation, A/C compressor + gear engaged S3_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque loss adaptation, gear engaged S3_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission coolant valve, open S3_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission fluid temperature 2 S3_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission gear ratio S3_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Upper adapted coupling point clutch 1 from microslip adaptation S3_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPTConfirmed

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0xB4 = 180 → 180200 = 0.9 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Upper adapted coupling point clutch 2 from microslip adaptation S3_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPTConfirmed

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0xA5 = 165 → 165200 = 0.825 A

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 S3_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 1 temperature time in range 2 S3_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 1 temperature time in range 3 S3_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 2 temperature time in range 0 S3_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 2 temperature time in range 1 S3_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 2 temperature time in range 2 S3_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Analysis, clutch 2 temperature time in range 3 S3_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Clutch 1 temperature time in range 0 S3_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Distance to empty S3_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016, 2018.

Drive cycles counter S3_MQB_TCM_DRIVE_CYCLES_COUNTERConfirmed

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x068C = 1676 → 1,676

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving time ecological S3_MQB_TCM_DRIVING_TIME_ECOLOGICALConfirmed

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x11 = 17 → 17 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving time manual S3_MQB_TCM_DRIVING_TIME_MANUALConfirmed

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x05 = 5 → 5 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Driving time sporty S3_MQB_TCM_DRIVING_TIME_SPORTYConfirmed

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x0D = 13 → 13 %

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Ignition cycles S3_MQB_TCM_IGNITION_CYCLESConfirmed

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026

Example reply from a 2016 Audi S3.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1D4F = 7503 → 7,503

Confirmed for 2016. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017 to 2026.

Mixture variation in adapted part load range 1 S3_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer S3_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer S3_ODO_7E1_2

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer S3_ODO_ECMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x014CDB = 85211 → 85,211 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer S3_ODO_V1Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x00020D00 = 134400 → 13440010 = 13,440 km

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Odometer S3_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Bits 8 to 31 of the reply, 24 bits.

Formula
val−40
Range
-40 to 16777175 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Supported for 2018. Not supported for 2016.

Odometer #2 S3_MQB_TCM_ODO_2Confirmed

  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x000D0600 = 853504 → 85350410 = 85,350.4 km

Confirmed for 2016, 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026.

Odometer at oxidation catalytic converter replacement S3_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer at SCR catalytic converter replacement S3_ODO_SCR_CATALYTIC

  • Service 22DID 4F41
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer with ECU installed S3_ODO_ECU_INSTALLED

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Odometer, dashboard S3_ODO_DASHConfirmed

  • Service 22DID 2203
  • Module714 → 77E
  • Every1 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x014227 = 82471 → 82,471 km

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Odometer, high resolution S3_ODO_HD

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016, 2018.

Odometer, mileage, HR S3_ODO_MILEAGE_HR

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 1 S3_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 2 S3_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 3 S3_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 4 S3_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 5 S3_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Operating time, temperature range 6 S3_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Remaining distance until reducing agent deficiency S3_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 1 S3_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 2 S3_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 3 S3_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 4 S3_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 5 S3_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 6 S3_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 7 S3_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Torque converter time in temperature range 8 S3_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 1999 to 2003, 2006 to 2012, 2014 to 2026.

Transmission module odometer S3_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 1999 to 2003, 2006 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Audi S3.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x014300 = 82688 → 82,688 km

Confirmed for 2018. In testing for 1999 to 2003, 2006 to 2012, 2014 to 2015, 2017, 2019 to 2026. Not supported for 2016.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.