Audi S5

Parameters

The Audi S5 has 1,265 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage S5_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1EDE = 7902 → 79021000+4 = 11.902 V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity S5_AUX_BAT_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery aging by capacity S5_AUX_BAT_AGE_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery aging by power S5_AUX_BAT_AGE_POW

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery capacity S5_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2007 to 2026.

12V battery current S5_AUX_BAT_C

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery sensor temperature S5_AUX_BAT_T_S

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery soc S5_AUX_BAT_SOC

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery temperature S5_AUX_BAT_T

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery total charge S5_AUX_BAT_CHRG_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery total discharge S5_AUX_BAT_DSCH_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery voltage S5_AUX_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Accelerator pedal, sensor 1 voltage S5_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Accelerator pedal, sensor 2 voltage S5_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Aux. hydraulic pump voltage S5_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2007 to 2026.

Battery acid stratification S5_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery charge level S5_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x43 = 67 → 67 %

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery condition for display S5_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery current S5_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483 A
Unit
A

0x00000001 = 1 → 11000 = 0.001 A

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery current filtered S5_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery internal resistance S5_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x12 = 18 → 18×20100 = 3.6

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery internal resistance, raw S5_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2007 to 2026.

Battery power reduction active S5_BMS_PWR_REDUCE_ACTConfirmed

  • Service 22DID 1E0A
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Battery sensor temperature S5_MQB_BAT_SEN_TConfirmed

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3D = 61 → 61−40 = 21 °C

Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023.

Battery temperature S5_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x33 = 51 → 51−40 = 11 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery total charge S5_MQB_BAT_TOT_CHG

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Battery total discharge S5_MQB_BAT_TOT_DIS

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Battery voltage S5_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1EDE = 7902 → 79021000+4 = 11.902 V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery voltage S5_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

In testing for 2007 to 2026.

Battery voltage at rest S5_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x21 = 33 → 3310+9 = 12.3 V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery voltage variant S5_PQ35_BAT_V_2Confirmed

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

0x0000 = 0 → 050 = 0 V

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Boost pressure S5_PQ35_CHG_PConfirmed

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

0x0D44 = 3396 → 33961000 = 3.396 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Bypass valve high pressure turbine inlet, raw voltage S5_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Cell state of charge max, index S5_BMS_CELL_SOC_MAX_IDXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge max, value S5_BMS_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x32 = 50 → 50 %

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge min, index S5_BMS_CELL_SOC_MIN_IDXConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge min, value S5_BMS_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x31 = 49 → 49 %

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage max, index S5_BMS_CELL_V_MAX_IDXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage max, value S5_BMS_CELL_V_MAXConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

0x0E5B = 3675 → 367510000 = 0.3675 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage min, index S5_BMS_CELL_V_MIN_IDXConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage min, value S5_BMS_CELL_V_MINConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

0x0E54 = 3668 → 366810000 = 0.3668 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage sum S5_BMS_CELL_V_SUMConfirmed

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x01DD = 477 → 47710 = 47.7 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value S5_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2007 to 2026.

Charge air pressure S5_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Charge air pressure actuator position digit.value S5_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Charge air pressure actuator, acknowledgment S5_CHG_AIR_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Charge air pressure, actual value S5_CHG_AIR_P_ACT

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2007 to 2026.

Charge air pressure, specified value S5_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2007 to 2026.

Charge air pressure: actual S5_PQ35_CHARGE_AIR_P_ACTUAL

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Charge air pressure: specified S5_PQ35_CHARGE_AIR_P_SPECIFIEDConfirmed

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

0x0C02 = 3074 → 3074×0.08 = 245.92

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Charge air temp at the turbocharger outlet, calculated S5_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATEDConfirmed

  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Charge limit overcharge protection S5_PQ35_CHG_LIM_OVER

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Charge pressure actuator, actual position S5_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure actuator, adaptation for lower stop S5_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, adaptation for upper stop S5_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, maximum sensor voltage S5_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, specified position S5_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2026.

Charge pressure actuator, specified value S5_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure before throttle valve, calculated actual value S5_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 2007 to 2026.

Charge pressure control adaptation higher than max. threshold S5_CHG_P_CTRL_ADPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control adaptation lower than min. threshold S5_CHG_P_CTRL_ADPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control specified value S5_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve activation pulse duty factor S5_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve position, actual value S5_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve position, target value S5_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve sensor voltage S5_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure control valve voltage, position closed S5_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure control valve voltage, position opened S5_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure regulator, lower threshold adaptation S5_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure regulator, upper threshold adaptation S5_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure sensor, unconditioned voltage S5_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Control module voltage S5_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x279C = 10140 → 101401000 = 10.14 V

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Cylinder charge specified value S5_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2007 to 2026.

Cylinder charge, actual value S5_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2007 to 2026.

DC-DC converter, current S5_DCDC_I

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

DC-DC converter, low voltage S5_DCDC_V_LOW

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

DC-DC converter, reserved current S5_DCDC_I_RSV

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

ECall battery charge level S5_ECALL_SOC

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

ECall battery status S5_ECALL_STATUS

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
1CRITICAL
2NORMAL

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electric motor battery energy S5_EM_HVBAT_E_INFO

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Generator target voltage S5_MQB_GEN_TRG_VConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
10.6 to 36.1 V
Unit
V

0x00 = 0 → 010+10.6 = 10.6 V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Generator voltage, actual S5_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2007 to 2026.

High pressure turbocharger actuator, activation S5_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

High voltage battery energy information S5_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2007 to 2026.

High voltage battery energy information S5_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2007 to 2026.

High voltage battery inlet temperature S5_HVBAT_INLET_T

  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

High voltage battery mode S5_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7

  • Service 22DID 7448
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

High voltage battery outlet temperature S5_HVBAT_OUTLET_T

  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

High voltage battery temperature S5_HVBAT_T

  • Service 22DID 2A0B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

HV battery coldest sensor S5_HVBAT_T_MIN_NO

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery current S5_HVBAT_CURRENTConfirmed

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−511
Range
-200 to 200 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery health S5_HVBAT_SOH

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 6524 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery highest cell S5_HVBAT_CELL_V_MAX_NOConfirmed

  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0C = 12 → 12

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery lowest cell S5_HVBAT_CELL_V_MIN_NOConfirmed

  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery state of charge S5_BMS_SOCConfirmed

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x31 = 49 → 49×100255 = 19.215686 %

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery state of charge, hd S5_BMS_SOC_HIRESConfirmed

  • Service 22DID F45B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x7D = 125 → 125×100255 = 49.019608 %

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery temperature load S5_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2026.

HV battery temperature, minimum S5_BMS_T_MIN

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery temperature, minimum, cell number S5_BMS_T_MIN_CELL

  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total ampere hours of charge S5_HVBAT_TOT_AH_CHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total ampere hours of discharge S5_HVBAT_TOT_AH_DCHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val549.31642
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total kilowatt hours of charge S5_HVBAT_TOT_KWH_CHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500300 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total kilowatt hours of discharge S5_HVBAT_TOT_KWH_DCHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199 to 250199 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Ignition angle current cylinder S5_PQ35_IGN_ANG_CYLConfirmed

  • Service 22DID 137A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−35.625
Range
-35.625 to 60 N·m
Unit
N·m

0x4D = 77 → 77×0.375−35.625 = -6.75 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Knock sensor voltage, cylinder 1 S5_KNOCK_SENS_V_CYL_1

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage, cylinder 3 S5_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 2 S5_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 3 S5_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 5 S5_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 6 S5_KNOCK_SENS_V_CYL_6

  • Service 22DID 13FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensors average voltage bank 1, variant 2 S5_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Maximum charge current S5_MAX_CHA_CUR_2Confirmed

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Maximum charge voltage S5_BMS_V_CHG_MAXConfirmed

  • Service 22DID 5171
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x021C = 540 → 54010 = 54 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum discharge current S5_MAX_DCHA_CUR_2

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Maximum dynamic charge current limit S5_BMS_I_CHG_LIM_DYNConfirmed

  • Service 22DID 1E1B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x00C8 = 200 → 200 A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum dynamic discharge current limit S5_BMS_I_DCHG_LIM_DYNConfirmed

  • Service 22DID 1E1C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x012C = 300 → 300 A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum predicted charge current limit S5_BMS_I_CHG_LIM_PREDConfirmed

  • Service 22DID 1E1D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0050 = 80 → 80 A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum predicted discharge current limit S5_BMS_I_DCHG_LIM_PREDConfirmed

  • Service 22DID 1E1E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0050 = 80 → 80 A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum discharge voltage S5_BMS_V_DCHG_MINConfirmed

  • Service 22DID 5170
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0186 = 390 → 39010 = 39 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum dynamic charge voltage S5_BMS_V_CHG_DYN_MINConfirmed

  • Service 22DID 5174
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0212 = 530 → 53010 = 53 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum dynamic discharge voltage S5_BMS_V_DCHG_DYN_MINConfirmed

  • Service 22DID 5175
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0191 = 401 → 40110 = 40.1 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum predicted charge voltage S5_BMS_V_CHG_PRED_MINConfirmed

  • Service 22DID 5172
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x01FA = 506 → 50610 = 50.6 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum predicted discharge voltage S5_BMS_V_DCHG_PRED_MINConfirmed

  • Service 22DID 5173
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x01C1 = 449 → 44910 = 44.9 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Non-vehicle energy requirement S5_NV_ENERGY_REQUIREMENT

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Service regeneration current duration S5_PQ35_SRV_REGEN_DUR

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.0001666667
Range
0 to 715827 min
Unit
min

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Temperature sensor for engine temperature management voltage S5_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Turbocharger inlet pressure corrected value S5_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Usable battery charge S5_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x1E = 30 → 30 Ah

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Modules

Module 3, temperature 1 S5_HVBAT_MOD3_T1Confirmed

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x00 = 0 → 0−50 = -50 °C

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Module 3, temperature 2 S5_HVBAT_MOD3_T2

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.

Module 3, temperature 3 S5_HVBAT_MOD3_T3

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.

Climate

A/C compressor power, actual S5_AC_CMPR_PWR_ACT

  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C compressor torque, requested S5_AC_COMP_TConfirmed

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

A/C refrigerant pressure, sensor 1 S5_AC_REFRIG_P_SENS1

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8810000
Range
0 to 576.708 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C refrigerant temperature, sensor 1 S5_AC_REFRIG_T_SENS1

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C refrigerant temperature, sensor 1 interior S5_AC_REFRIG_T_SENS1_INT

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Air conditioning compressor power consumption S5_PQ35_AC_COMP_PWR

  • Service 22DID 27D6
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val25
Range
0 to 10.2 kW
Unit
kW

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Air conditioning compressor shutdown requirement S5_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Air conditioning compressor torque S5_PQ35_AC_COMP_TRQ

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Ambient air temperature S5_AAT_7E0_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Ambient temperature S5_AAT_V2Confirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

0x0000 = 0 → 0128 = 0 °C

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Barometric pressure S5_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2026.

Cabin humidity S5_CABIN_HUMIDITY

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

CO2 content interior S5_CABIN_CO2

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Outside humidity S5_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Outside temperature S5_AATConfirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 °C
Unit
°C

0x003C = 60 → 6010 = 6 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Recirculation flap actual position S5_MQB_RECIRC_FLAP_ACT

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap fresh air threshold S5_MQB_RECIRC_FLAP_FRESH_THR

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap target position S5_MQB_RECIRC_FLAP_TRG

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap threshold S5_MQB_RECIRC_FLAP_THR

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Windshield temperature S5_WINDSHIELD_T

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Clocks

Time since engine start S5_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Control

Absolute pedal position, drive S5_APP_D

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Accelerator pedal release detection threshold voltage S5_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Air gab vacuum sensor S5_AIR_GAB_VACUUM_SNS

  • Service 22DID 1816
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Brake S5_BRAKE_PRESSEDConfirmed

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Brake booster low pressure, actual S5_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 2007 to 2026.

Brake booster pressure S5_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2007 to 2026.

Brake booster pressure S5_PQ35_BRAKE_BOOSTER_P

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08291753
Range
0 to 5434
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Brake booster raw pressure S5_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2007 to 2026.

Brake disk drying S5_BDD_ACTIVE

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Brake disk drying, odometer at last activation S5_BDD_ODO

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Brake pedal position S5_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Brake pressure S5_BRAKE_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2007 to 2026.

Brake pressure S5_BRAKE_P_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2026.

Brake pressure S5_MQB_TCM_BRAKE_P

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Brake pressure S5_PQ35_BRAKE_P

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Brake pressure reading valid? S5_BRAKE_PRESSED_VALIDConfirmed

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Brake pressure sensor S5_BRAKE_P_SNS

  • Service 22DID 1816
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Brake system vacuum pump active S5_BRAKE_SYSTEM_VACUUM

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Downshift point adaptation voltage S5_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Electronic differential lock: active S5_EDL_ACTIVE

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electronic differential lock: front left brake temperature S5_EDL_FR_L_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electronic differential lock: front right brake temperature S5_EDL_FR_R_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electronic differential lock: rear left brake temperature S5_EDL_RR_L_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electronic differential lock: rear right brake temperature S5_EDL_RR_R_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Hydraulic brake booster: active S5_HYD_BRAKE_BOOST_ACTIVE

  • Service 22DID 1810
  • Module713 → 77D
  • Every2 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Pressure in brake servo unit S5_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2007 to 2026.

Requested brake torque, auxiliary system S5_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2007 to 2026.

Steering wheel angle S5_STEER_ANGLEConfirmed

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 2B29
  • Module713 → 77D
  • Every100 ms
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 rad
Unit
rad

0x0000 = 0 → 01000 = 0 rad

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Pedals

Accelerator pedal position sensor 1 S5_APP_POS1Confirmed

  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x0EA3 = 3747 → 37471000 = 3.747 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Accelerator pedal position sensor 2 S5_APP_POS2Confirmed

  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x0751 = 1873 → 18731000 = 1.873 V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Drivetrain

Driver torque requested #1 S5_ENG_TRQ_REQ_1

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Driver torque requested #2 S5_ENG_TRQ_REQ_2

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016 to 2017, 2024. Supported for 2018.

Distance traveled since diagnostic trouble codes cleared S5_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1D2F = 7471 → 7,471 km

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Distance traveled while mil was activated S5_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Number of warm-ups since diagnostic trouble codes cleared S5_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

ECU

Misfires, cylinder 2 S5_MISFIRES__CYL__2Confirmed

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0851 = 2129 → 2,129

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Misfires, cylinder 4 S5_MISFIRES__CYL__4Confirmed

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0C3E = 3134 → 3,134

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Torque converter slip S5_TORQUE_CONVERTER_SLIP_TCMConfirmed

  • Service 22DID 2131
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Engine

A/C clutch S5_CLIMATE_A_C_CLCH

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C compressor load S5_CLIMATE_A_C_COMP_LOAD

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C compressor torque S5_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

A/C refrigerant pressure S5_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2007 to 2026.

Adaptation of loss torque S5_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2026.

Adaptation of throttle valve S5_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder1 fast diagnosis S5_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder1 slow diagnosis S5_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder2 fast diagnosis S5_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder2 slow diagnosis S5_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder3 fast diagnosis S5_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder3 slow diagnosis S5_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder4 fast diagnosis S5_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptation val.cylinder4 slow diagnosis S5_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2026.

Adaptive mode S5_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Air conditioning compressor pressure, linear raw value S5_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2007 to 2026.

Air conditioning compressor refrigerant pressure S5_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2007 to 2026.

Air conditioning compressor torque S5_AC_COMP_TQ

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2007 to 2026.

Air conditioning compressor torque request S5_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2026.

Air conditioning refrigerant pressure S5_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2007 to 2026.

Air filling S5_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Air leakage S5_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2007 to 2026.

Air mass meter 1 S5_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Air mass, actual value, mg/stroke S5_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2026.

Air mass, specified value S5_AIR_MASS_SPEC

  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Air pollution level S5_CLIMATE_AIR_POLUTION_LVLConfirmed

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Ambient air pressure S5_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 2007 to 2026.

Ambient air temperature S5_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x71 = 113 → 1132−50 = 6.5 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Ambient air temperature, v1 S5_AAT_V1Confirmed

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

0x0BEB = 3051 → 3051×0.18−460 = 89.18 °F

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Ambient temperature S5_AAT_7E0

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2007 to 2026.

Ambient temperature S5_AAT_7E0_2

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Analysis, clutch 1, maximum temperature S5_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2026.

Analysis, clutch 2, maximum temperature S5_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2026.

Automatic engine starts counter S5_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Automatic transmission fluid temperature, lifetime max S5_ATF_MAX

  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Aux. hydraulic pump internal temperature S5_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Aux. hydraulic pump, current S5_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2007 to 2026.

Average ignition timing angle delay adjustment S5_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Avg. injection time S5_AVG_INJ_TIMEConfirmed

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

0x0000056A = 1386 → 13862500 = 0.5544 ms

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Avg. injection time S5_AVG_INJ_TIME_7E0

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2007 to 2026.

Basic correction factor:, cylinder 1, filtered S5_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2007 to 2026.

Basic correction factor:, cylinder 2, filtered S5_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2007 to 2026.

Basic correction factor:, cylinder 3, filtered S5_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2007 to 2026.

Basic correction factor:, cylinder 4, filtered S5_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2007 to 2026.

Battery module controller temperature, 3 S5_BMS_BMCE_T3

  • Service 22DID 180E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Boost press before throttle: calculated actual value S5_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Boost pressure actuator, commanded duty S5_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 2007 to 2026.

Boost pressure commanded S5_PQ35_BOOST_P_CMDConfirmed

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure, actual S5_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Boost pressure, actual S5_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 2007 to 2026.

Boost pressure, target S5_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2007 to 2026.

Boost regulation duty, commanded value S5_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Boost regulator feedback S5_BOOST_REGULATOR_FEEDBACK

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Bypass valve high pressure turbine inlet, activation S5_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Bypass valve high pressure turbine inlet, actual value S5_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2007 to 2026.

Bypass valve high pressure turbine inlet, offset closed S5_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2007 to 2026.

Bypass valve high pressure turbine inlet, offset open S5_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2007 to 2026.

Bypass valve high pressure turbine inlet, target value S5_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2007 to 2026.

Bze_q_elad S5_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2007 to 2026.

Bze_q_lad S5_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2007 to 2026.

Cabin temperature S5_CABIN_TConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x007D = 125 → 12510 = 12.5 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Cabin temperature S5_IAT

  • Service 22DID 2613
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016 to 2017, 2024. Supported for 2018.

Calculated oil temperature S5_PQ35_CALCULATED_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Camshaft adaptation exhaust bank 1, phase position S5_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft adaptation intake bank 1, phase position S5_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft adaptation intake, phase position S5_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 2007 to 2026.

Camshaft adaptation, counter due to knock S5_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Camshaft adaptation, exhaust bank 1, phase position S5_CAM_ADPT_EXH_BANK_1Confirmed

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

0xFFDC = -36 → -3650 = -0.72 °

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Camshaft adaptation, intake bank 1, phase position S5_CAM_ADPT_INT_BANK_1Confirmed

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

0x001B = 27 → 2750 = 0.54 °

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Camshaft adaptation, intake deviation S5_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment intake bank 1, activation % S5_CAM_ADJ_INT_BANK_1

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Camshaft adjustment intake test bank 1 S5_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Camshaft adjustment outlet test bank 1 S5_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Camshaft adjustment, exhaust bank 1, actual value S5_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, exhaust bank 1, specified value S5_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, exhaust bank 2, actual value S5_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, exhaust bank 2, specified value S5_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, exhaust, actual value S5_CAM_ADJ_EXH_ACT

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, exhaust, specified value S5_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, intake bank 1, actual value S5_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, intake bank 1, specified value S5_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, intake, actual value S5_CAM_ADJ_INT_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft adjustment, intake, specified value S5_CAM_ADJ_INT_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Camshaft end position S5_PQ35_CAMS_ENDConfirmed

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

0x00D3 = 211 → 2115 = 42.2 °

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Camshaft position, deviation from the base position S5_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2007 to 2026.

Camshaft start position S5_PQ35_CAMS_START

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cat. converter oxygen storage capacity measured S5_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2007 to 2026.

Cat. temperature, bank 1 S5_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2007 to 2026.

Cat. temperature, bank 2 S5_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2007 to 2026.

Catalyst temperature, calculated S5_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2007 to 2026.

Centrifugal oil temperature S5_PQ35_CENTRIFUGAL_OIL_T

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Chain elongation inlet, mileage at last adaptation S5_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2026.

Chain elongation outlet, mileage at last adaptation S5_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 S5_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Chain elongation, no of valid initial values, intake bank 1 S5_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Charge air cooler downstream air pressure S5_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Clutch #1 maximum temperature S5_PQ35_CLUTCH_1_MAXIMUM_TConfirmed

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

0x0000 = 0 → 0 °C

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Supported for 2016.

Clutch #2 maximum temperature S5_PQ35_CLUTCH_2_MAXIMUM_TConfirmed

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

0x0000 = 0 → 0 °C

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Supported for 2016.

Clutch 0 temperature calculated S5_MQB_DL382_CLUTCH_0_T_CALCULATEDConfirmed

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x02B8 = 696 → 696 °C

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 temperature S5_PQ35_CLUTCH_1_TConfirmed

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

0x00 = 0 → 0 °C

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 temperature protection warning 1 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 temperature protection warning 2 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 temperature S5_PQ35_CLUTCH_2_TConfirmed

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

0xA3 = 163 → 163 °C

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 temperature protection warning 1 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 temperature protection warning 2 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch center central plate temperature S5_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2026.

Clutch temperature calculated S5_MQB_DL382_CLUTCH_T_CALCULATED

  • Service 22DID 18E3
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded crankshaft torque S5_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016 to 2017, 2024. Supported for 2018.

Compression test cylinder 1 S5_PQ35_COMPRESSION_TEST_CYL_1Confirmed

  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x0000 = 0 → 02 = 0 rpm

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Compression test cylinder 2 S5_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Compression test cylinder 3 S5_PQ35_COMP_TEST_CYL_3

  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Compression test, cylinder 1 S5_COMPRESSION_TEST_CYL_1

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2026.

Compression test, cylinder 2 S5_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2026.

Compression test, cylinder 3 S5_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2026.

Compression test, cylinder 4 S5_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2026.

Control module temperature S5_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Control module temperature S5_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-40 to 150 °C
Unit
°C

0x0B58 = 2904 → 290410−273.1 = 17.3 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Control module temperature S5_MQB_TCM_ECU_T

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Converter loss torque S5_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0046 = 70 → 7020 = 3.5 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Coolant circulation pump, activation S5_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant circulation pump, control S5_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant fan 1 activation, $1117 S5_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Coolant fan 1 duty cycle S5_PQ35_COOL_FAN_1_DUTYConfirmed

  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017.

Coolant fan 1, activation S5_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant fan 1, activation S5_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant fan 2 duty cycle S5_PQ35_COOL_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Coolant fan 2, activation S5_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant fan, requested by A/C S5_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2007 to 2026.

Coolant shut-off valve, closed S5_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2007 to 2026.

Coolant temperature at engine outlet, calculated S5_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at engine outlet, calculated S5_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at engine start S5_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at engine start S5_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet S5_COOLANT_TConfirmed

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0E6C = 3692 → 369210−273.1 = 96.1 °C

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Coolant temperature at radiator outlet S5_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet 2 S5_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet v.1 S5_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet, actual value S5_ECT_RADIATOR_OUTLET_ACT

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet, actual value S5_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature at radiator outlet, specified value S5_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature difference between engine and radiator S5_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature linear S5_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2929710000000−48
Range
-48 to 143.9978 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature modeled value S5_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature, maximum value S5_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2007 to 2026.

Coolant temperature, minimum value S5_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2007 to 2026.

Correction factor of oil temperature for engine protection S5_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 2007 to 2026.

Correction values for main pressure adaptation S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPTConfirmed

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0800 = 2048 → 2048100 = 20.48 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Counter steer support S5_CNT_STEER_SUPPORT_ACTIVE

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Counter steer support, steering torque S5_CNT_STEER_SUPPORT_STEERING_TRQ

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Crankshaft rotation angle when closing the quantity control valve S5_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Critical engine oil level S5_PQ35_OIL_LVL_CRITConfirmed

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

0x0B5F = 2911 → 2911250 = 11.644 mm

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

CTR_MIS_DC_MMV_CYL_SAE, 0 S5_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 S5_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 S5_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Current N215 pressure control valve 1 S5_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current N216 pressure control valve 2 S5_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current N217 pressure control valve 3 S5_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current N218 pressure control valve 4 S5_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current N233 pressure control valve 5 S5_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current solenoid S5_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current type of driver counter S5_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Cylinder 1 internal torque S5_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Cylinder 2 internal torque S5_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Cylinder 3 internal torque S5_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Cylinder 4 internal torque S5_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Cylinder block temperature sensor S5_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Cylinder head temperature S5_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2007 to 2026.

Desired torque raw S5_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2026.

Diesel particulate filter differential pressure variant 2 S5_PQ35_DPF_DIFF_P_2Confirmed

  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x0803 = 2051 → 2,051

Confirmed for 2016. In testing for 2007 to 2015, 2017 to 2026.

Diesel particulate filter exhaust gas flow volume S5_MQB_DPF_EXH_VOLConfirmed

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Diesel particulate filter surface temperature S5_DPF_SFC_TConfirmed

  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

0x00A9 = 169 → 16910−273.1 = -256.2 °C

Confirmed for 2016. In testing for 2007 to 2015. Not supported for 2017.

Differential pressure S5_PQ35_DIFF_P

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Direct injections counter S5_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2007 to 2026.

Driver demand torque S5_MQB_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Driving mode sensor, hall sensor a S5_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Driving position S5_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Driving resistance index S5_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2007 to 2026.

Dynamic average of ignition angle delay adjustment S5_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Ea888b boost pressure control, adaptation value 0 S5_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2007 to 2026.

Ea888b boost pressure control, adaptation value 1 S5_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2007 to 2026.

Ea888b boost pressure control, adaptation value 2 S5_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2007 to 2026.

Ea888b boost pressure control, adaptation value 3 S5_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2007 to 2026.

Ea888b boost pressure regulator, commanded S5_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Early ignition counter for toque reduction, cylinder 1 S5_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for toque reduction, cylinder 2 S5_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for toque reduction, cylinder 3 S5_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for toque reduction, cylinder 4 S5_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder 1 S5_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder 2 S5_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder 3 S5_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder 4 S5_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 S5_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 S5_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 S5_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 S5_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, total, cylinder 1 S5_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, total, cylinder 2 S5_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, total, cylinder 3 S5_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter, total, cylinder 4 S5_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Effective injection duration S5_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2007 to 2026.

EGT after catalyst, model bank b S5_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2007 to 2026.

Elector motor 1 torque S5_EM_TORQ_1Confirmed

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x06F2 = 1778 → 177832 = 55.5625 N·m

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Elector motor 3 torque S5_EM_TORQ_3Confirmed

  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x0000 = 0 → 032 = 0 N·m

Confirmed for 2016. In testing for 2007 to 2015. Not supported for 2017, 2023 to 2024.

Electric additional coolant pump control, high circle S5_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2007 to 2026.

Electric motor 2 torque S5_EM_TORQ_2Confirmed

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x063D = 1597 → 159732 = 49.90625 N·m

Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2023.

Electric motor non-vehicle power limitation S5_EM_NV_PWR_LIM

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electric motor power limitation S5_EM_PWR_LIM

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Energy balance of last driving cycle S5_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 2007 to 2026.

Energy content S5_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2007 to 2026.

Engine air mass, specified value S5_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2007 to 2026.

Engine compartment temperature raw value S5_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2007 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016 to 2017, 2024. Supported for 2018.

Engine drag torque S5_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine oil level S5_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2007 to 2026.

Engine oil level S5_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Engine oil level current value S5_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Engine oil pressure S5_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 2007 to 2026.

Engine oil sump temperature S5_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2007 to 2026.

Engine oil temperature S5_EOT

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Engine oil temperature S5_EOT_7E0Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

0x00 = 0 → 0−60 = -60 °C

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Engine oil temperature S5_EOT_7E0_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Engine oil temperature measured value S5_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Engine oil temperature sensor 2 S5_EOT_SENS_2

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Engine oil temperature, pulse sensor S5_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Engine outlet coolant temperature calculated S5_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Engine protection, torque limit S5_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine radiator fan request S5_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024. Supported for 2016 to 2018.

Engine start quantity S5_PQ35_ENG_START_QTY

  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engine temperature control actuator S5_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Engine temperature management actuator, after-run stop S5_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Engine temperature management actuator, duty cycle activation S5_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Engine temperature management actuator, raw value S5_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Engine temperature management actuator, specified value S5_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2007 to 2026.

Engine temperature management actuator, stop open S5_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Engine torque S5_ENG_TQ

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine torque S5_ENG_TQ_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine torque S5_ENG_TQ_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine torque S5_ENGINE_TORQUEConfirmed

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Engine torque S5_MQB_TCM_ENG_TORQUE

  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engine torque S5_MQB_TCM_ENGINE_TORQUE

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engine torque S5_PQ35_ENG_TORQUEConfirmed

  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 N·m
Unit
N·m

0x0000 = 0 → 032 = 0 N·m

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Engine torque S5_PQ35_ENG_TRQ

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Engine torque limitation S5_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2026.

Engine torque limitation S5_MQB_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engine torque loss S5_MQB_TCM_ENGINE_TORQUE_LOSS

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Environment data camshaft input 1 S5_PQ35_ENVD_CAM_IN_1Confirmed

  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Excessive temperature protection S5_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Exhaust camshaft, adaptation bias S5_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2007 to 2026.

Exhaust camshaft, adaptation sensor tolerance S5_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2007 to 2026.

Exhaust gas temperature S5_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature - calculated after catalyst S5_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature at probe before precat, model value S5_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature before catalyst S5_EXHAUST_GAS_T_BEFORE_CATALYST

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Exhaust gas temperature before catalytic converter S5_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature sensor 1 S5_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature sensor 1 S5_EXH_GAS_T_SENS_1_7E0

  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas temperature sensor 1 S5_PQ35_EXH_GAS_T_1

  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Exhaust gas temperature sensor 1, bank 2 S5_EXH_GAS_T_SENS_1_2

  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas temperature sensor 2 S5_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Exhaust gas temperature sensor 3 S5_EXH_GAS_T_SENS_3

  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas temperature sensor 3, bank 2 S5_EXH_GAS_T_SENS_3_2

  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas temperature sensor 4 S5_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust gas temperature, sensor 4, bank 2 S5_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust temperature before the catalyst, modeled S5_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error S5_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Field limit value S5_PQ35_FIELD_LIMConfirmed

  • Service 22DID 11F6
  • Module7E0
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

0x6673 = 26227 → 26227100 = 262.27

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Front left deflector temperature S5_CLIMATE_FR_L_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0059 = 89 → 8910 = 8.9 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Front left temperature flap actual value S5_CLIMATE_FR_L_T_FLP_ACT_VALUE

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front right deflector temperature S5_CLIMATE_FR_R_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0063 = 99 → 9910 = 9.9 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Front right temperature flap actual value S5_CLIMATE_FR_R_T_FLP_ACT_VALUE

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Fuel metering valve position S5_PQ35_FUEL_METERConfirmed

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Fuel temperature S5_PQ35_FUEL_TConfirmed

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0000 = 0 → 010−273.1 = -273.1 °C

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016, 2024.

Generator current S5_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2007 to 2026.

Generator load S5_PQ35_GEN_LOADConfirmed

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.

Generator load normalized value S5_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Generator load signal S5_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Generator load signal S5_GEN_LOAD_SIG_7E0

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Generator load signal S5_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Generator performance S5_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2007 to 2026.

Generator torque request S5_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Heater circulation pump, nominal value S5_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Heater support pump, specified value S5_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Height correction S5_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2007 to 2026.

High pressure control, adaptation S5_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2007 to 2026.

High pressure regulation, adaptation value S5_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2026.

Hill descent control S5_HDC_ACTIVE

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Hill descent control, incline S5_HDC_INCLINE

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Hybrid temperature S5_MQB_TCM_HYBRID_TConfirmed

  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

0x0393 = 915 → 915 °C

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

ID of current driving program S5_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

IGA_CYL_KNK, 0 S5_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2026.

IGA_CYL_KNK, 1 S5_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2026.

IGA_CYL_KNK, 2 S5_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2026.

IGA_CYL_KNK, 3 S5_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2026.

IGA_IGC, 0 S5_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2007 to 2026.

IGA_IGC, 1 S5_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2007 to 2026.

IGA_IGC, 2 S5_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2007 to 2026.

IGA_IGC, 3 S5_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2007 to 2026.

Ignition angle current cylinder, actual value S5_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2007 to 2026.

Ignition timing angle retard, cylinder 4 S5_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Injection amount deviation cylinder 1 S5_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2007 to 2026.

Injection amount deviation cylinder 2 S5_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2007 to 2026.

Injection amount deviation cylinder 2 S5_INJ_AMOUNT_DEV_CYL_2_7E0

  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Injection amount deviation cylinder 3 S5_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2007 to 2026.

Injection amount deviation cylinder 4 S5_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2007 to 2026.

Injection amount deviation cylinder 5 S5_INJ_AMOUNT_DEV_CYL_5

  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Injector 1 rail pressure calibration point 1 S5_PQ35_INJ_1_RAIL_P_1Confirmed

  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Injector 1 rail pressure calibration point 2 S5_PQ35_INJ_1_RAIL_P_2Confirmed

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0050 = 80 → 8020000 = 0.004 ms

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Injector 2 rail pressure calibration point 1 S5_PQ35_INJ_2_RAIL_P_1Confirmed

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0xFFFC = -4 → -420000 = -0.0002 ms

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Injector 2, rail pressure calibration point 1 S5_INJ_2_RAIL_P_1Confirmed

  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Injector 3 rail pressure calibration point 1 S5_PQ35_INJ_3_RAIL_P_1Confirmed

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x06A1 = 1697 → 169720000 = 0.08485 ms

Confirmed for 2016, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017.

Injector 4 rail pressure calibration point 3 S5_PQ35_INJ_4_RAIL_P_3Confirmed

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Injector 5, rail pressure calibration point 2 S5_INJ_5_RAIL_P_2Confirmed

  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Inlet flaps - actual value S5_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Inlet flaps - requested value S5_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Intake air temperature S5_IAT_7E0

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2007 to 2026.

Intake air temperature before throttle valve, raw value S5_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2007 to 2026.

Intake air temperature in intake manifold S5_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2007 to 2026.

Intake air temperature raw value S5_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Intake camshaft adaptation unit 1 phase length S5_PQ35_CAMS_ADAPT_PHASE_1

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Intake camshaft signal edge position adapted edge 2 S5_PQ35_CAMS_EDGE_POS_2Confirmed

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

0x6480 = 25728 → 2572816−32 = 1,576 °

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Intake camshaft signal edge position adapted edge 3 S5_PQ35_CAMS_EDGE_POS_3Confirmed

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

0x6480 = 25728 → 2572816−32 = 1,576 °

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Intake camshaft signal edge position adapted edge 4 S5_PQ35_CAMS_EDGE_POS_4

  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft signal edge position adapted edge 5 S5_PQ35_CAMS_EDGE_POS_5

  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft signal edge position adapted edge 6 S5_PQ35_CAMS_EDGE_POS_6

  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft signal edge position adapted edge 7 S5_PQ35_CAMS_EDGE_POS_7

  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft signal edge position adapted edge 8 S5_PQ35_CAMS_EDGE_POS_8

  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft signal edge position adapted value edge 1 S5_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake camshaft, adaptation bias S5_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2007 to 2026.

Intake camshaft, adaptation sensor tolerance S5_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2007 to 2026.

Intake manifold pressure calculated S5_MQB_INT_MAN_P

  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Intake manifold pressure raw value S5_INT_MANIFOLD_P_RAW

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2007 to 2026.

Intake manifold pressure, commanded S5_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Intake manifold pressure, corrected S5_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Intake manifold runner control, acknowledgment S5_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Intake manifold runner control, activation S5_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Intake model air mass flow filtered value S5_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2007 to 2026.

Intake phase deviation, actual value S5_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2007 to 2026.

Integrated mass of air since engine start S5_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2007 to 2026.

Integrated mass of air since the first engine start S5_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2007 to 2026.

Intercooler air output temperature S5_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Kick down S5_MQB_TCM_KICK_DOWNConfirmed

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Kilometers driven since last event on K1 S5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Kilometers driven since last event on K2 S5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Knock retard 4 S5_KNOCK_RETARD_4Confirmed

  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×34 = 0 °

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Knock sensor 1 test S5_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Knock sensor 2 test S5_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Knock sensor 3 test S5_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Knock sensor 4 test S5_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Knock sensor, cylinder 1 S5_KNOCK_SENS_CYL_1

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Knock sensor, cylinder 1 S5_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2007 to 2026.

Knock sensor, cylinder 2 S5_KNOCK_SENS_CYL_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Knock sensor, cylinder 2 S5_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 2007 to 2026.

Knock sensor, cylinder 2 S5_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2007 to 2026.

Knock sensor, cylinder 3 S5_KNOCK_SENS_CYL_3

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Knock sensor, cylinder 3 S5_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2007 to 2026.

Knock sensor, cylinder 4 S5_KNOCK_SENS_CYL_4

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Knock sensor, cylinder 4 S5_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2007 to 2026.

Lambda output value S5_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2007 to 2026.

Lambda, actual value S5_LAMBDA_ACTConfirmed

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

0x0000 = 0 → 0×1220750000000 = 0

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Launch control counter, variant 1 S5_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Launch control counter, variant 2 S5_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Leg deflector temperature S5_CLIMATE_LEG_DEFL_T

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Long term fuel trim at idle, direct injection S5_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2007 to 2026.

Long term fuel trim at idle, port injection S5_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2007 to 2026.

Long-term adaptation of intake manifold injection S5_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Long-term adaptation of intake manifold injection at idle S5_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2026.

Lost torque adaptation A/C + driving mode S5_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2026.

Lost torque adaptation driving mode S5_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation S5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

M009, desired solenoid out 10 S5_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

M009, desired solenoid out 11 S5_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

M009, desired solenoid out 12 S5_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

M009, desired solenoid out 13 S5_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

M009, desired solenoid out 14 S5_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Main cat oxygen storage capacity age correction factor S5_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2007 to 2026.

Manifold absolute pressure, raw value S5_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Manual engine starts counter S5_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Mass air flow over throttle valve S5_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2007 to 2026.

Mass air flow rate S5_MAF_RATE

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2007 to 2026.

Mass air flow through throttle S5_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2007 to 2026.

Mass air flow, commanded S5_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2007 to 2026.

Mass airflow sensor 1 bank 1 raw value S5_MQB_MAF_1_B1_RAWConfirmed

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Mass flow through throttle valve S5_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2007 to 2026.

Max permissible engine torque S5_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2026.

Maximum ECU temperature S5_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2026.

Maximum filling correction factor from knock control S5_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 2007 to 2026.

Maximum oil level for the service interval S5_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Mean engine air mass S5_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2007 to 2026.

Mean engine air mass S5_PQ35_MEAN_AIR_MASSConfirmed

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968
Unit
Raw value

0x0000 = 0 → 032 = 0

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Mean injection quantity S5_MEAN_INJ_QUANTITYConfirmed

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

0x3684 = 13956 → 13956100 = 139.56

Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2023.

Mileage with ECU installed S5_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2007 to 2026.

Minimum oil level for the service interval S5_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Misfires / 1000 revolutions, cylinder 1 S5_MISFIRES_1000REV_C1Confirmed

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Misfires / 1000 revolutions, cylinder 2 S5_MISFIRES_1000REV_C2Confirmed

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Misfires counter:, cylinder 1 S5_MIS_CNT_1

  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires counter:, cylinder 2 S5_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires counter:, cylinder 3 S5_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires counter:, cylinder 4 S5_MIS_CNT_4

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires counter:, cylinder 5 S5_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires counter:, cylinder 6 S5_MIS_CNT_6

  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions 2 S5_MIS_PER_1000_2_7E0_7E0Confirmed

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Misfires per 1000 revolutions 4 S5_MIS_PER_1000_4_7E0Confirmed

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection S5_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions, cylinder 2 S5_MIS_PER_1000_2_7E0

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection S5_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions, cylinder 3 S5_MIS_PER_1000_3_7E0

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection S5_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection S5_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires total S5_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires total S5_MISFIRES_TOTALConfirmed

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Misfires, cylinder 1 S5_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 1 S5_MISFIRES_C1

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 2 S5_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 2 S5_MISFIRES_C2

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 3 S5_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 3 S5_MISFIRES_C3

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 3 S5_MISFIRES_C3_ECMConfirmed

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x02F7 = 759 → 759

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Misfires, cylinder 4 S5_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires, cylinder 4 S5_MISFIRES_C4

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Mixture adaptation factor at partial load S5_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

N_32 S5_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2007 to 2026.

NL_PRE, 0 S5_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2007 to 2026.

NL_PRE, 1 S5_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2007 to 2026.

NL_PRE, 2 S5_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2007 to 2026.

NL_PRE, 3 S5_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2007 to 2026.

Number of injections S5_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded S5_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Number of warnings due to increased centrifugal oil temperature S5_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

NV energy requirement S5_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2007 to 2026.

Oil ash residue S5_PQ35_OIL_ASH_RESIDUEConfirmed

  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

0x0000 = 0 → 010 = 0

Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.

Oil dynamic average measurement S5_PQ35_OIL_DYN_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Oil fill level S5_PQ35_OIL_FILL_LEVEL

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Oil last dynamic measurement S5_PQ35_OIL_DYN_LAST

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Oil level S5_OIL_LEVELConfirmed

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x23FE = 9214 → 92142500 = 3.6856 cm

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Oil level method 1 S5_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2007 to 2026.

Oil level method 2 S5_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2007 to 2026.

Oil level method 3 S5_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2007 to 2026.

Oil level test method 1 S5_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Oil level test method 2 S5_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Oil level test method 3 S5_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Oil level, average dynamic value S5_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Oil level, static measured S5_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2007 to 2026.

Oil level, static measurement S5_OIL_LEVEL_STATIC_7E0

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2007 to 2026.

Oil p S5_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2026.

Oil pressure actual S5_MQB_TCM_EOP_ACTUAL

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Oil pressure actual current S5_MQB_TCM_EOP_ACTUAL_I

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Oil pressure control valve activation pulse duty factor S5_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Oil pressure control valve, activation pulse duty factor S5_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Oil pressure sensor raw value S5_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2007 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status S5_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Oil pressure sensor, raw value S5_OIL_P_SENS_RAW_7E0

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Oil pressure switch activation, high pressure S5_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Oil pressure switch for high pressure, closed S5_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Oil pressure switch for low pressure, closed S5_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2026.

Oil pressure switch for piston-cooling jets, closed S5_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Oil pressure switch valve activation S5_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Oil pressure target S5_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2007 to 2026.

Oil pressure target S5_OIL_P_TGT_7E0

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio S5_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Oil pressure valve switch, control S5_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Oil pressure, actual value S5_OIL_P_ACT_7E0

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2026.

Oil pressure, actual value S5_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Oil pressure, actual value S5_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2026.

Oil temp 2 S5_PQ35_ENGINE_OIL_T_2Confirmed

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Oil temperature S5_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Oil temperature S5_PQ35_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 202F
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−58
Range
-58 to 197 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Oil temperature variant S5_PQ35_OIL_T_2Confirmed

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0000 = 0 → 010−273.1 = -273.1 °C

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Oil thermal wear S5_DASH_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Oil warning threshold S5_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2007 to 2026.

Open cam shaft angle at quantity control valve S5_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2007 to 2026.

Outside temperature S5_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2007 to 2026.

Outside temperature, system calculated S5_OUTSIDE_T_SYSTEMConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 °C
Unit
°C

0x0049 = 73 → 7310 = 7.3 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Overall energy balance S5_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2007 to 2026.

Oxygen control, adaptation value at part. load S5_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature S5_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2007 to 2026.

Oxygen sensor 1 bank 1 lambda value S5_PQ35_O2_SEN_1_LAMBDAConfirmed

  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Number

0xF3B5 = -3147 → -3147100 = -31.47

Confirmed for 2016. In testing for 2007 to 2015, 2017 to 2026.

Particle filter, field regeneration lock status S5_PARTICLE_FLT_FIELD_REGENConfirmed

  • Service 22DID 11C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Piston cooling nozzles, control S5_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Piston-cooling jets, activation S5_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Port injection injections counter S5_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2007 to 2026.

Post-injection 1 start position S5_PQ35_POST_INJ_1_STARTConfirmed

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

0x6973 = 26995 → 2699550 = 539.9 °

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Post-injection 3 activation duration S5_PQ35_POST_INJ_3_ACTIVATION_DURATIONConfirmed

  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

0x1EF1 = 7921 → 7921×0.41000 = 3.1684 ms

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Post-injection 3 start position S5_PQ35_POST_INJ_3_STARTConfirmed

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

0xF6B3 = -2381 → -238150 = -47.62 °

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Pre-injection 2 duration S5_PQ35_PRE_INJ_2_DURATIONConfirmed

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

0xFFFE = -2 → -2×0.41000 = -0.0008 ms

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Pressure before throttle valve - actual value S5_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Pressure before throttle valve - sensor measured S5_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2007 to 2026.

Pressure sensor 1 temperature S5_MQB_DL382_P_SENSOR_1_T

  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Pressure sensor 2 temperature S5_MQB_DL382_P_SENSOR_2_T

  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Pressure supply actual pressure S5_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed

  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0xC803 = -14333 → -14333100 = -143.33 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Pressure supply actual pressure analog digital value S5_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 S5_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2007 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 S5_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2007 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 S5_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2007 to 2026.

Radiator fan 1, commanded duty S5_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Radiator fan 2, commanded duty S5_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

Radiator fan actual duty S5_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Radiator fan commanded duty S5_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Radiator outlet coolant temperature commanded S5_PQ35_RAD_COOL_T_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Radiator output coolant temp: actual S5_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Rated drive torque S5_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2007 to 2026.

Reached maximum temperature S5_PQ35_REACHED_MAXIMUM_TConfirmed

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0000 = 0 → 0 °C

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Rear cat converter temperature, main catalytic converter model value S5_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2007 to 2026.

Rear deflector temperature S5_CLIMATE_RR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 400 °C
Unit
°C

0x0073 = 115 → 11510 = 11.5 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Reducing agent tank volume, act. value filtered S5_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 2007 to 2026.

Refrigerant pressure S5_CLIMATE_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x00 = 0 → 05 = 0 bar

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Regulation factor total S5_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Relative load value S5_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 2007 to 2026.

Relay for reserve coolant pump status S5_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Requested torque, amount for auxiliary units S5_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Reserve torque S5_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2026.

Result of crankcase ventilation test, fail S5_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Result of crankcase ventilation test, successful S5_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Route data, active S5_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Secondary air injection sensor 1 S5_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2007 to 2026.

SEG_AD_MMV_ER_H, 0 S5_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_H, 2 S5_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_H, 3 S5_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_L, 0 S5_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_L, 2 S5_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_L, 3 S5_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_MID, 0 S5_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_MID, 1 S5_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER_MID, 2 S5_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER, 1 S5_SEG_AD_MMV_ER_1

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER, 2 S5_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

SEG_AD_MMV_ER, 3 S5_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2007 to 2026.

Service limit S5_SERVICE_LIM

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2026.

Service limit S5_SERVICE_LIM_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2026.

Service limit value S5_PQ35_SRV_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2007 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017, 2024. Supported for 2016, 2018.

SIM card, SIM card in main unit S5_SIM_CARD_SIM_CARD

  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Spark efficiency deviation at idle, maximum S5_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Spark efficiency deviation at part load, maximum S5_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Stop signal switch S5_MQB_TCM_STOP_SIGNAL_SWITCH

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Sum of misfires counter S5_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Tank fill level diagnostic reference value S5_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2007 to 2026.

TCO_1_ST S5_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

TCO_1_SYS S5_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Temperature after evaporator S5_CLIMATE_T_AFTER_EVAPConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0018 = 24 → 2410 = 2.4 °C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Temperature at air conditioner heat exchanger output S5_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Temperature sensor 14 S5_T_SENS_14

  • Service 22DID 1EBB
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2007 to 2026.

Temperature sensor for engine temperature management S5_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Temperature sensor for engine temperature management, target value S5_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Test of catalytic converter status, canceled S5_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Test of catalytic converter, measured value S5_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2007 to 2026.

Thermostat, actual S5_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Thermostat, commanded S5_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Throttle regulator nominal value S5_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Throttle valve adapter position S5_PQ35_THROT_VALVE_ADAPT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

TI_1_MPI, 0 S5_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_1_MPI, 1 S5_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_1_MPI, 2 S5_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_1_MPI, 3 S5_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_1, 1 S5_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_1, 2 S5_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_1, 3 S5_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_2, 0 S5_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_2, 1 S5_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_2, 2 S5_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_2, 3 S5_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_3, 0 S5_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_3, 1 S5_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_3, 2 S5_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

TI_MES4_PLS_3, 3 S5_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2007 to 2026.

Time in after-run S5_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2007 to 2026.

Time since reset S5_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2007 to 2026.

Timing angle retardation cylinder 1 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_1

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Timing angle retardation cylinder 2 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Timing angle retardation cylinder 3 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_3

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Timing angle retardation cylinder 4 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_4

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Timing deviation after chain replacement, exhaust bank 1 S5_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Timing deviation after chain replacement, intake bank 1 S5_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Timing deviation after other repairs, intake bank 1 S5_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Timing deviation after other repairs, intake bank 1 S5_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Timing deviation current value exhaust bank 1 S5_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Timing deviation current value intake bank 1 S5_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2007 to 2026.

Torque converter: torque loss S5_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque factor S5_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Torque increase request from ESP S5_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque limit S5_PQ35_LIM_TRQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Torque limitation S5_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque limitation S5_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque limitation S5_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque limitation, clutch protection S5_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque loss adaptation S5_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque loss adaptation at idle S5_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque loss adaptation, A/C compressor S5_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque reduction due to exhaust temperature S5_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.276
Unit
Number

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Torque reduction request from ESP S5_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque request, sum of auxiliary aggregate S5_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque transmitting function, ratio S5_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2007 to 2026.

Total mass of gasoline and ethyl alcohol in oil S5_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 2007 to 2026.

Transmission drag torque S5_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2026.

Transmission fluid temperature, calculated S5_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2026.

Transmission fluid temperature, modeled maximum reached S5_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2007 to 2026.

Transmission torque losses S5_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2026.

Turbine actuator 1 bank 1 activation S5_PQ35_TURB_ACT_1_B1Confirmed

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x059E = 1438 → 1438100 = 14.38 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Turbine actuator 1 bank 1: activation S5_ACTConfirmed

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2016. In testing for 2007 to 2015. Supported for 2024. Not supported for 2017, 2023.

Upper adapted coupling point K1 from macro slip path adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Upper adapted coupling point K2 from macro slip path adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Valve lift system, result of last switch, intake S5_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Valve lift system, valve lift, exhaust S5_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Valve lift system, valve lift, intake S5_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Valve timing, the difference between the, actual and the set angle S5_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 2007 to 2026.

Variable valve timing, intake, bank 1, regulation S5_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Variable valve timing, intake, bank 1, switch on S5_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Wear index S5_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Wear index %, 0=new engine S5_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

DPF

Service regeneration status S5_PQ35_SRV_REGEN_STATConfirmed

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x27 = 39 → 39

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Soot mass calculated S5_PQ35_SOOT_MASS_CALCConfirmed

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

0x057F = 1407 → 1407100 = 14.07

Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.

EGR

Exhaust gas recirculation 2: filter press loss, modeled S5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Exhaust gas recirculation 2: filter press loss, simulated S5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Internal

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016 to 2017, 2024.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2016 to 2017, 2024.

Fluids

Automatic transmission fluid temperature S5_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x41 = 65 → 65−40 = 25 °C

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Oil level, critical S5_OIL_CRIT

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Oil level, max S5_OIL_MAX

  • Service 22DID 11C4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Oil level, min S5_OIL_MIN

  • Service 22DID 11C5
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Fuel

Activation of fuel pump electronics S5_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Counter of fuel entry in oil S5_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Error counter bad fuel S5_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2007 to 2026.

Fuel consumption S5_FUEL_CONSConfirmed

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2023.

Fuel consumption - actual drive cycle S5_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2007 to 2026.

Fuel consumption per driving cycle S5_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2007 to 2026.

Fuel filter: water level sensor 1 S5_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1

  • Service 22DID 197C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Fuel flow S5_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2007 to 2026.

Fuel flow rate S5_PQ35_FUEL_FLOW

Pelican can show this parameter as the fuel rate.

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Fuel high pressure, actual value S5_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2007 to 2026.

Fuel high pressure, control deviation S5_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2007 to 2026.

Fuel high pressure, specified value S5_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2007 to 2026.

Fuel injector time deviation, cylinder 1 S5_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Fuel injector time deviation, cylinder 2 S5_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Fuel injector time deviation, cylinder 2 S5_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Fuel injector time deviation, cylinder 3 S5_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Fuel injector time deviation, cylinder 4 S5_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2026.

Fuel level S5_FLI

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2026.

Fuel level S5_PQ35_FUEL_LEVEL_7E0_2206

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Fuel level S5_PQ35_FUEL_LVL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Fuel level input S5_FLI_714

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 229A
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 L
Unit
L

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Fuel level input % S5_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Fuel level input, v1 S5_FUEL_LEVEL_INPUT_V1Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x1130 = 4400 → 4400100 = 44 L

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Fuel level variant S5_PQ35_FUEL_LVL_2Confirmed

  • Service 22DID 100C
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.

Fuel low pressure, actual value S5_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2007 to 2026.

Fuel low pressure, specified value S5_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2007 to 2026.

Fuel mass request, integral controller S5_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2007 to 2026.

Fuel mass request, proportional controller S5_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2007 to 2026.

Fuel mix correction coefficient S5_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2007 to 2026.

Fuel part from EVAP system S5_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2007 to 2026.

Fuel pressure regulator position S5_PQ35_FUEL_P_REGConfirmed

  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Fuel pressure regulator valve: specified value rail pressure S5_SPEC_VALUE_RAIL_PConfirmed

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

0x0CF6 = 3318 → 3318×100 = 331,800

Confirmed for 2016. In testing for 2007 to 2015. Not supported for 2017, 2023 to 2024.

Fuel pressure, low actual S5_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2026.

Fuel pump adaptation S5_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2007 to 2026.

Fuel pump specified value S5_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Fuel pump, commanded duty S5_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 2007 to 2026.

Fuel rate S5_FUEL_RATE

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2007 to 2026.

Fuel rate difference, injector/sensor S5_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2007 to 2026.

Fuel tank fill level S5_FUEL_TANK_FILL_LEVEL

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 2007 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2024. Supported for 2016, 2018.

Fuel temperature S5_FUEL_TConfirmed

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

0x9D = 157 → 157×0.75−48 = 69.75 °C

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Fuel temperature S5_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2007 to 2026.

Fuel temperature S5_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2026.

Fuel volume S5_FLI_VOL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 22B0
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

High fuel pressure control deviation S5_HIGH_FUEL_P_CONTROL_DEVIATIONConfirmed

  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

0x1BC7 = 7111 → 7111×100 = 711,100

Confirmed for 2016. In testing for 2007 to 2015. Not supported for 2017, 2023 to 2024.

High fuel pressure, actual S5_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2007 to 2026.

High fuel pressure, actual value S5_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2007 to 2026.

High fuel pressure, commanded S5_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2007 to 2026.

High fuel pressure, regulation error S5_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2007 to 2026.

High fuel pressure, target S5_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2007 to 2026.

High pressure fuel pressure actual S5_PQ35_FUEL_P_HIGHConfirmed

  • Service 22DID 1169
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

0x7FFF = 32767 → 32767×100 = 3,276,700

Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017.

High pressure fuel pressure commanded S5_PQ35_FUEL_P_HIGH_CMD

  • Service 22DID 116A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Long term fuel trim at idle S5_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 2007 to 2026.

Long term fuel trim at idle S5_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2007 to 2026.

Long term fuel trim bank 1 S5_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2007 to 2026.

Long term fuel trim direct injection at load S5_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2007 to 2026.

Long term fuel trim port injection at load S5_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2007 to 2026.

Low fuel pressure, actual S5_LOW_FUEL_P_ACTConfirmed

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

0x158D = 5517 → 551710 = 551.7 kPa

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Low fuel pressure, commanded S5_LOW_FUEL_P_CMDConfirmed

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

0x1655 = 5717 → 571710 = 571.7 kPa

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual S5_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2007 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum S5_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2007 to 2026.

Short term fuel trim bank 1 S5_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2007 to 2026.

GPS

Satellites, tracked S5_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2007 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x05 = 5 → 5

Confirmed for 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017.

Satellites, visible S5_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2007 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017.

Lights

Brake light S5_BRAKE_LIGHT_ONConfirmed

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Brake light reading valid? S5_BRAKE_LIGHT_ON_VALIDConfirmed

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Movement

A/C compressor speed S5_CLIMATE_A_C_COMP_SPD

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Acceleration S5_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Acceleration S5_ACCEL_7E0

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Acceleration S5_ACCELERATION

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Acceleration S5_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Acceleration/deceleration mode S5_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Accelerator pedal limit S5_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Accelerator pedal position S5_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Accelerator pedal position S5_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Accelerator pedal position 1 S5_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Accelerator pedal position 2 S5_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Accelerator pedal sensor 1 S5_PQ35_ACCEL_PED_1Confirmed

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

0x0008 = 8 → 85 = 1.6 mV

Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026.

Accelerator pedal sensor 2 S5_PQ35_ACCEL_PED_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Accelerator pedal torque limit S5_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Aux. hydraulic pump RPM S5_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2007 to 2026.

Camshaft speed S5_CAM_SPD

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2007 to 2026.

Camshaft speed S5_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2026.

Camshaft speed S5_PQ35_CAMS_SPD

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.3
Range
-9830.4 to 9830.1 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Compressor speed S5_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2026.

Crankshaft speed S5_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2007 to 2026.

Crankshaft speed, RPM S5_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2026.

Engine RPM S5_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2007 to 2026.

Engine RPM at idle required S5_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2007 to 2026.

Front left wheel speed S5_FL_VSS_V2

  • Service 22DID 1800
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front left wheel speed S5_TIRE_FL_SPDConfirmed

  • Service 22DID 2B1B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Front left wheel speed S5_TIRE_FL_SPD_713

  • Service 22DID 2B1B
  • Module713 → 77D
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front left wheel speed S5_TIRE_FL_SPD_V3Confirmed

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.

Front right wheel speed S5_FR_VSS_V2

  • Service 22DID 1801
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front right wheel speed S5_TIRE_FR_SPDConfirmed

  • Service 22DID 2B1C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Front right wheel speed S5_TIRE_FR_SPD_713

  • Service 22DID 2B1C
  • Module713 → 77D
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front right wheel speed S5_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.

Idle speed specified rpm S5_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2026.

Injection speed injector 0 S5_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2026.

Injection speed injector 1 S5_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2026.

Injection speed injector 2 S5_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2026.

Injection speed injector 3 S5_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2026.

Input shaft speed 1 S5_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2007 to 2026.

Input shaft speed 2 S5_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2007 to 2026.

Lateral acceleration S5_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Longitudinal acceleration S5_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Longitudinal acceleration, raw S5_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2007 to 2026.

Misfires per 1000 rpm, all cylinders S5_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 rpm:, cylinder 1 S5_MIS_PER_1000_RPM_1

  • Service 22DID 1484
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 rpm:, cylinder 3 S5_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 rpm:, cylinder 4 S5_MIS_PER_1000_RPM_4

  • Service 22DID 1485
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 rpm:, cylinder 5 S5_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires per 1000 rpm:, cylinder 6 S5_MIS_PER_1000_RPM_6

  • Service 22DID 1487
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires/1000 rpm, cylinder 1 S5_MISFIRES_1000_RPM_C1

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires/1000 rpm, cylinder 2 S5_MISFIRES_1000_RPM_C2

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires/1000 rpm, cylinder 3 S5_MISFIRES_1000_RPM_C3

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Misfires/1000 rpm, cylinder 4 S5_MISFIRES_1000_RPM_C4

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Mixture adaptation factor at idle speed S5_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Rear left wheel speed S5_RL_VSS_V2

  • Service 22DID 1802
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear left wheel speed S5_TIRE_RL_SPDConfirmed

  • Service 22DID 2B1D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Rear left wheel speed S5_TIRE_RL_SPD_713

  • Service 22DID 2B1D
  • Module713 → 77D
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear left wheel speed S5_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.

Rear right wheel speed S5_RR_VSS_V2

  • Service 22DID 1803
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear right wheel speed S5_TIRE_RR_SPDConfirmed

  • Service 22DID 2B1E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Rear right wheel speed S5_TIRE_RR_SPD_713

  • Service 22DID 2B1E
  • Module713 → 77D
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear right wheel speed S5_TIRE_RR_SPD_V3Confirmed

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.

Reducing agent pump, differential speed calculated S5_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2007 to 2026.

Specified idle RPM S5_MQB_DQ250_SPECIFIED_IDLE_RPM

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Speed ​​output S5_MQB_DQ250_SPD_OUTPUTConfirmed

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Transmission input shaft speed S5_PQ35_TRANS_IN_SPDConfirmed

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x0E72 = 3698 → 36982 = 1,849 rpm

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.

Transmission input speed S5_MQB_TCM_TRANSMISSION_INPUT_SPDConfirmed

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x014C = 332 → 3324 = 83 rpm

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Transmission input speed S5_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission output speed S5_MQB_TCM_TRANSMISSION_OUTPUT_SPDConfirmed

  • Service 22DID 2103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Transmission output speed S5_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Vehicle lateral acceleration, raw value S5_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2007 to 2026.

Vehicle speed S5_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Vehicle speed S5_VSS_7E1

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2026.

Vehicle speed ESP S5_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2007 to 2026.

Vehicle speed from transmission S5_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Vehicle speed, HR S5_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2007 to 2026.

Yaw acceleration, raw value S5_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2007 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2024. Supported for 2016 to 2018.

Stats

Driving time in eco mode S5_DRIVE_TIME_ECOConfirmed

Value may be wrong, needs more validation. Proportion of time spent driving in eco mode

  • Service 22DID 0303
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x44 = 68 → 682.5 = 27.2 %

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Driving time in manual mode S5_DRIVE_TIME_MANUALConfirmed

Value may be wrong, needs more validation. Proportion of time spent driving in manual mode

  • Service 22DID 0305
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Driving time in sport mode S5_DRIVE_TIME_SPORTConfirmed

Value may be wrong, needs more validation. Proportion of time spent driving in sport mode

  • Service 22DID 0304
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x17 = 23 → 232.5 = 9.2 %

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Launch control count S5_LAUNCH

How many times you've initiated launch control on the car.

  • Service 22DID 5200
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000000
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Total drive time S5_DRIVE_TIMEConfirmed

  • Service 22DID 0302
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 h
Unit
h

0x026F = 623 → 6234 = 155.75 h

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Tires

Entire energy throughput S5_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 2007 to 2026.

Front left flat tire indicator S5_TPMS_FR_L_FLAT_TIRE_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front left tire pressure diffusion indicator S5_TPMS_FR_L_TIRE_P_DIFF_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front left wheel speed S5_FL_WHL_SPD

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Front right flat tire indicator S5_TPMS_FR_R_FLAT_TIRE_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front right tire pressure diffusion indicator S5_TPMS_FR_R_TIRE_P_DIFF_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Front right wheel speed S5_FR_WHL_SPD

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Rear left flat tire indicator S5_TPMS_RR_L_FLAT_TIRE_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear left tire pressure diffusion indicator S5_TPMS_RR_L_TIRE_P_DIFF_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear left wheel speed S5_RL_WHL_SPD

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Rear right flat tire indicator S5_TPMS_RR_R_FLAT_TIRE_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear right tire pressure diffusion indicator S5_TPMS_RR_R_TIRE_P_DIFF_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Rear right wheel speed S5_RR_WHL_SPD

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Steering wheel angle S5_MQB_SWA_ALT

  • Service 22DID 1804
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.562 °
Unit
°

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Steering wheel temperature S5_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2007 to 2026.

Tire pressure monitoring available S5_TPMS_AVAIL

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Transmission

Actual position clutch 1 duty cycle factor 1 S5_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1

  • Service 22DID 3832
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position clutch 1 duty cycle factor 2 S5_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2

  • Service 22DID 3833
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position clutch 2 duty cycle factor 1 S5_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1

  • Service 22DID 383B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position clutch 2 duty cycle factor 2 S5_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2

  • Service 22DID 383C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position of gear positioner a S5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position of gear positioner b S5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position of gear positioner c S5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Actual position of gear positioner d S5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Adaptation counter PF lockup clutch S5_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Adaptation counter torque converter lockup clutch S5_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, clutch a S5_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, clutch b S5_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, clutch c S5_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, clutch d S5_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, clutch e S5_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, fast fill time, clutch a S5_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, fast fill time, clutch b S5_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, fast fill time, clutch c S5_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, fast fill time, clutch d S5_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation counter, fast fill time, clutch e S5_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Adaptation inflation current PF lockup clutch S5_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2007 to 2026.

Adaptation inflation time torque converter lockup clutch S5_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2007 to 2026.

All-wheel drive clutch blockage degree S5_MQB_HAL_CLUTCH_BLOCK

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val×8
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

All-wheel drive clutch fully open S5_MQB_HAL_CLUTCH_OPEN

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 0 commanded pressure offset S5_MQB_DL382_CLUTCH_0_CMD_P_OFFSET

  • Service 22DID 1426
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 absolute pressure S5_MQB_DL382_CLUTCH_1_ABSOLUTE_P

  • Service 22DID 13CC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 actual pressure S5_PQ35_CLUTCH_1_ACTUAL_P

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 actual pressure raw value S5_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUEConfirmed

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x00 = 0 → 010−1 = -1 bar

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristic point 0 position S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POSConfirmed

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 adaptation basic characteristic point 1 moment S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENTConfirmed

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 adaptation basic characteristic point 1 position S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristic point 2 moment S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENTConfirmed

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 adaptation basic characteristic point 2 position S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POSConfirmed

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 adaptation basic characteristic point 3 moment S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENTConfirmed

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 adaptation basic characteristic point 3 position S5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristics point 0 position S5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristics point 1 position S5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38AF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristics point 2 position S5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 7000
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation basic characteristics point 3 position S5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 7001
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation clutch end position closed S5_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38FF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 adaptation clutch end position open S5_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38FE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 characteristic curve shift S5_PQ35_CLUTCH_1_CHAR_CURVE_SHIFTConfirmed

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

0x0000 = 0 → 0×9.810000 = 0 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 commanded pressure S5_PQ35_CLUTCH_1_CMD_P

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 failed adaptations counter S5_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 friction value correction factor S5_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTORConfirmed

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×0.09766 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 lower adaptation point S5_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Clutch 1 nominal pressure S5_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2007 to 2026.

Clutch 1 pressure S5_MQB_DL382_CLUTCH_1_PConfirmed

  • Service 22DID 214C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x00 = 0 → 010−1 = -1 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 protection function engaged quantity S5_PQ35_CLUTCH_1_PROT_ENGAGED_QTY

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 successful adaptations counter S5_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0xE701 = 59137 → 59,137

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 upper adaptation point S5_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Clutch 1 valve current: actual S5_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 1 valve current: specified S5_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 absolute pressure S5_MQB_DL382_CLUTCH_2_ABSOLUTE_P

  • Service 22DID 13CD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 actual pressure S5_PQ35_CLUTCH_2_ACTUAL_P

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 actual pressure raw value S5_PQ35_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUEConfirmed

  • Service 22DID 10FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x00 = 0 → 010−1 = -1 bar

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Clutch 2 actual torque S5_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristic point 0 moment S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENTConfirmed

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0D03 = 3331 → 333120 = 166.55 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 adaptation basic characteristic point 0 position S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POSConfirmed

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 adaptation basic characteristic point 1 moment S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristic point 1 position S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristic point 2 moment S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENTConfirmed

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x0000 = 0 → 020 = 0 N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 adaptation basic characteristic point 2 position S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristic point 3 moment S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristic point 3 position S5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristics point 0 position S5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38FA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristics point 1 position S5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38FB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristics point 2 position S5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 38FC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation basic characteristics point 3 position S5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 38FD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation clutch end position closed S5_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38AB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation clutch end position open S5_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38AA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation end position closed S5_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 adaptation end position opened S5_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 characteristic curve shift S5_PQ35_CLUTCH_2_CHAR_CURVE_SHIFTConfirmed

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

0x0000 = 0 → 0×9.810000 = 0 mm

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Clutch 2 commanded pressure S5_PQ35_CLUTCH_2_CMD_P

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 failed adaptations counter S5_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0xFFFF = 65535 → 65,535

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 friction value correction factor S5_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 lower adaptation point S5_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Clutch 2 pressure S5_MQB_DL382_CLUTCH_2_PConfirmed

  • Service 22DID 214D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x00 = 0 → 010−1 = -1 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 protection function engaged quantity S5_PQ35_CLUTCH_2_PROT_ENGAGED_QTY

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 successful adaptations counter S5_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0xFFFF = 65535 → 65,535

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 2 upper adaptation point S5_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Clutch 2 valve current: actual S5_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch 2 valve current: specified S5_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch adaptation values initial kill point 0 for K1 S5_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1Confirmed

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch adaptation values initial kill point 0 for K2 S5_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2Confirmed

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch adaptation values lower current point adaptation K1 S5_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1Confirmed

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch adaptation values lower current point adaptation K2 S5_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2Confirmed

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch kiss point rapid adaptation remaining S5_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Clutch overheating, clutch S5_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Clutch temperature S5_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Correction values for main press adaptation: high press on clutch 1 S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x9502 = -27390 → -27390100 = -273.9 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Correction values for main press adaptation: low press on clutch 1 S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0xB802 = -18430 → -18430100 = -184.3 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Correction values for main pressure adaptation high pressure on clutch 2 S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x74FC = 29948 → 29948100 = 299.48 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Correction values for main pressure adaptation low pressure on clutch 2 S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0xE701 = -6399 → -6399100 = -63.99 bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Current gear S5_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2007 to 2026.

Current gear S5_MQB_TCM_I_GEARConfirmed

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

0x01 = 1 → 1−2 = -1

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Current gear S5_MQB_TCM_I_GEAR_DQ200

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Current gear S5_PQ35_GEAR

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Current lower pressure point clutch 1 from current to pressure adaptation S5_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x0A = 10 → 10×5 = 50 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Current lower pressure point clutch 2 from current to pressure adaptation S5_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Current N371 pressure control valve 6 lock-up clutch S5_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2007 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation S5_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x05 = 5 → 5×5 = 25 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Current upper pressure point clutch 2 from current to pressure adaptation S5_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x00 = 0 → 0×5 = 0 mA

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Driving strategy mountain factor S5_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTORConfirmed

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Driving strategy sport factor S5_PQ35_DRIVING_STRATEGY_SPORT_FACTORConfirmed

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×1700255 = 0 %

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Dynamic shift program S5_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for oxygen shift, cylinder 1 S5_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for oxygen shift, cylinder 2 S5_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for oxygen shift, cylinder 3 S5_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Early ignition counter for oxygen shift, cylinder 4 S5_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Engaged position side a gear selector 1-3 S5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Engaged position side a gear selector 2-4 S5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x3200 = 12800 → 12800×10010000 = 128 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Engaged position side a gear selector 5 and neutral S5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x6E00 = 28160 → 28160×10010000 = 281.6 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Engaged position side a gear selector 6 and reverse S5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0xB004 = 45060 → 45060×10010000 = 450.6 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Engaged position side b gear selector 1-3 S5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engaged position side b gear selector 2-4 S5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engaged position side b gear selector 5 and neutral S5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engaged position side b gear selector 6 and reverse S5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Engine specified torque during transmission intervention S5_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2026.

Fast fill time, clutch a S5_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2007 to 2026.

Fast fill time, clutch b S5_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2007 to 2026.

Fast fill time, clutch c S5_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2007 to 2026.

Fast fill time, clutch d S5_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2007 to 2026.

Fast fill time, clutch e S5_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2007 to 2026.

Fill pressure, clutch a S5_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2007 to 2026.

Fill pressure, clutch b S5_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2007 to 2026.

Fill pressure, clutch c S5_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2007 to 2026.

Fill pressure, clutch d S5_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2007 to 2026.

Fill pressure, clutch e S5_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2007 to 2026.

Gear S5_GEAR_V2Confirmed

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Gear actuator adaptation engaged position G1 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1Confirmed

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0003 = 3 → 3100 = 0.03 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position G2 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Gear actuator adaptation engaged position G3 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3Confirmed

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position G4 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4Confirmed

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position G5 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5Confirmed

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x3D16 = 15638 → 15638100 = 156.38 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position G6 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6Confirmed

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x6E03 = 28163 → 28163100 = 281.63 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position G7 S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7Confirmed

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x311B = 12571 → 12571100 = 125.71 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation engaged position GR S5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Gear actuator adaptation synchronization position G1 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1Confirmed

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x5A55 = 23125 → 23125100 = 231.25 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position G2 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2Confirmed

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position G3 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Gear actuator adaptation synchronization position G4 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4Confirmed

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0000 = 0 → 0100 = 0 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position G5 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5Confirmed

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x1F16 = 7958 → 7958100 = 79.58 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position G6 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6Confirmed

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0500 = 1280 → 1280100 = 12.8 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position G7 S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7Confirmed

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0xA11B = -24293 → -24293100 = -242.93 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear actuator adaptation synchronization position reverse S5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Gear selector a adaptation neutral position S5_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x0400 = 1024 → 1024100 = 10.24 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector b adaptation neutral position S5_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Gear selector c adaptation neutral position S5_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x041B = 1051 → 1051100 = 10.51 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector d adaptation neutral position S5_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOSConfirmed

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

0x1200 = 4608 → 4608100 = 46.08 mm

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G1 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1Confirmed

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x5A06 = 23046 → 23046100 = 230.46 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G2 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2Confirmed

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G3 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3Confirmed

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G4 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4Confirmed

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x4904 = 18692 → 18692100 = 186.92 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G5 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5Confirmed

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x2C04 = 11268 → 11268100 = 112.68 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position G6 S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6Confirmed

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Gear selector synchronous position, reverse S5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_RConfirmed

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x5903 = 22787 → 22787100 = 227.87 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Input shaft 1 S5_MQB_INPUT_SHAFT_1

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Input shaft 2 S5_MQB_INPUT_SHAFT_2

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Launch control counter, clutch 1 S5_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Load shift flaps, actual value S5_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Load shift flaps, specified value S5_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation S5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Lower adapted coupling point clutch 2 from kiss point adaptation S5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Mileage of oxidation catalytic converter S5_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2007 to 2026.

Neutral position gear selector 1-3 S5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x6400 = 25600 → 25600×10010000 = 256 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Neutral position gear selector 2-4 S5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Neutral position gear selector 5 and neutral S5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Neutral position gear selector 6 and reverse S5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Nominal pressure clutch 2 S5_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2007 to 2026.

Output shaft 1 S5_MQB_OUTPUT_SHAFT_1

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Output shaft 2 S5_MQB_OUTPUT_SHAFT_2

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Powertrain overall gear ratio S5_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2007 to 2026.

Pressure_clutch_1 S5_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Pressure_clutch_2 S5_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2007 to 2026.

Road resistance S5_PQ35_ROAD_RESISTANCEConfirmed

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Selected gear S5_PQ35_SELECTED_GEARConfirmed

  • Service 22DID 15AA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2015, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.

Selected gear S5_SELECTED_GEAR

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2007 to 2026.

Shift process, selected gear S5_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Shift process, target gear S5_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Specified torque clutch 1 S5_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Specified torque clutch 1 - data S5_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2007 to 2026.

Specified torque clutch 2 S5_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Specified torque clutch 2 - data S5_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2007 to 2026.

Stiffness point pressure clutch 1 S5_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1

  • Service 22DID 1419
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Stiffness point pressure clutch 2 S5_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2

  • Service 22DID 141A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Synchronous position side a gear selector 1-3 S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0xB004 = 45060 → 45060×10010000 = 450.6 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side a gear selector 2-4 S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0xB004 = 45060 → 45060×10010000 = 450.6 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side a gear selector 5 and neutral S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x5046 = 20550 → 20550×10010000 = 205.5 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side a gear selector 6 and reverse S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x2800 = 10240 → 10240×10010000 = 102.4 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side b gear selector 1-3 S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side b gear selector 2-4 S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side b gear selector 5 and neutral S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Synchronous position side b gear selector 6 and reverse S5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Time since shift S5_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2007 to 2026.

Torque converter amplification S5_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2007 to 2026.

Torque converter lockup clutch status S5_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUSConfirmed

  • Service 22DID 7078
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Torque loss adaptation, A/C compressor + gear engaged S5_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Torque loss adaptation, gear engaged S5_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2026.

Transmission coolant valve, open S5_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

Transmission fluid temperature 2 S5_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2026.

Transmission gear ratio S5_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2007 to 2026.

Transmission part 1 pressure actual S5_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 1 pressure commanded S5_MQB_TCM_TRANSMISSION_PART_1_P_CMD

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 1 valve current actual S5_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 1 valve current commanded S5_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 2 pressure actual S5_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 2 pressure commanded S5_MQB_TCM_TRANSMISSION_PART_2_P_CMD

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 2 valve current actual S5_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Transmission part 2 valve current commanded S5_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Upper adapted coupling point clutch 1 from microslip adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Upper adapted coupling point clutch 2 from microslip adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Working hours S5_PQ35_WORKING_HOURSConfirmed

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

0x0D000000 = 218103808 → 218103808×2360000 = 1,211.687822

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Trips

Analysis, clutch 1 temperature time in range 1 S5_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 1 temperature time in range 2 S5_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 1 temperature time in range 3 S5_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 2 temperature time in range 0 S5_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 2 temperature time in range 1 S5_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 2 temperature time in range 2 S5_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Analysis, clutch 2 temperature time in range 3 S5_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Average consumption, category 0 S5_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 1 S5_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 2 S5_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 3 S5_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 4 S5_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 5 S5_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Average consumption, category 6 S5_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Clutch 1 adaptation kiss point part 1 odometer reading S5_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

0x0000 = 0 → 0×10 = 0 km

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Clutch 1 temperature time in range 0 S5_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2007 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading S5_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

0xFFFF = 65535 → 65535×10 = 655,350 km

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Counter steer support, odometer, last activated S5_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACT

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Distance to empty S5_PQ35_DIST_EMPTY

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Drive cycles counter S5_MQB_TCM_DRIVE_CYCLES_COUNTER

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Driving time ecological S5_MQB_TCM_DRIVING_TIME_ECOLOGICAL

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Driving time manual S5_MQB_TCM_DRIVING_TIME_MANUAL

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Driving time sporty S5_MQB_TCM_DRIVING_TIME_SPORTY

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Ignition cycles S5_MQB_TCM_IGNITION_CYCLES

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Mixture variation in adapted part load range 1 S5_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Odometer S5_MQB_TCM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer S5_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00001D70 = 7536 → 7,536 km

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Odometer S5_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2007 to 2026.

Odometer S5_ODO_7E1_2

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2026.

Odometer S5_ODO_ECMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000124 = 292 → 292 km

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Odometer S5_PQ35_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer #2 S5_MQB_TCM_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer #3 S5_PQ35_ODO_3

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer at oxidation catalytic converter replacement S5_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2007 to 2026.

Odometer reading at fourth-to-last warning S5_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading at last adaptation S5_TPMS_ODO_RDG_AT_LAST_ADAPT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading at last warning S5_TPMS_ODO_RDG_AT_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading at next-to-last warning S5_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading at third-to-last warning S5_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading four adaptations ago S5_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading three adaptations ago S5_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer reading two adaptations ago S5_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Odometer with ECU installed S5_ODO_ECU_INSTALLED

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2007 to 2026.

Odometer, alternate S5_PQ35_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2007 to 2026.

Odometer, high resolution S5_ODO_HDConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 m
Unit
m

0x007249A4 = 7489956 → 7,489,956 m

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Odometer, mileage, HR S5_ODO_MILEAGE_HR

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2007 to 2026.

Operating time, temperature range 1 S5_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Operating time, temperature range 2 S5_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Operating time, temperature range 3 S5_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Operating time, temperature range 4 S5_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Operating time, temperature range 5 S5_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Operating time, temperature range 6 S5_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2007 to 2026.

Range remaining S5_RANGE_V2Confirmed

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x0000 = 0 → 0 mi

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Range remaining, displayed S5_RANGE_DSP

  • Service 22DID 22E0
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Remaining distance until reducing agent deficiency S5_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 2007 to 2026.

Torque converter time in temperature range 1 S5_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 2 S5_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 3 S5_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 4 S5_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 5 S5_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 6 S5_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 7 S5_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Torque converter time in temperature range 8 S5_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2007 to 2026.

Trip consumption, short S5_TRIP_USE_SHORT

  • Service 22DID 0530
  • Module714 → 77E
  • Every500 ms
  • Testing

Bits 238 to 255 of the reply, 18 bits. The value is signed.

Formula
val1000
Range
-131 to 131 kWh/100 mi
Unit
kWh/100 mi

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.