Cadillac XT5

Parameters

The Cadillac XT5 has 223 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Calculated engine oil temperature XT5_EOT_CALCConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x5A = 90 → 90−40 = 50 °C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Charge air cooler temperature sensor 1 XT5_CHARGE_AIR_COOLER_T_SNS_1

  • Service 22DID 30AD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Charge air cooler temperature sensor 2 XT5_CHARGE_AIR_COOLER_T_SNS_2

  • Service 22DID 30AE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018. Supported for 2019.

Ignition 1 voltage XT5_IGN_1_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

M control module voltage XT5_M_CTRL_MODULE_VConfirmed

  • Service 22DID 0042
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x0000 = 0 → 01000 = 0 V

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2019.

Clocks

Time since engine start XT5_RUNTMConfirmed

  • Service 22DID 11A1
  • Module7E0
  • Every1 s
  • Testing for 2016, 2020 to 2021, 2023 to 2026

Example reply from a 2022 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2017 to 2019, 2022. In testing for 2016, 2020 to 2021, 2023 to 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Brake pedal position circuit signal XT5_BRAKE_PEDAL_POSConfirmed

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x51 = 81 → 81

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Doors

Hood position XT5_HOOD_POSConfirmed

  • Service 22DID 905C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Hood switch XT5_HOOD_SWITCHConfirmed

  • Service 22DID 247A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

0x00 = 0 → 051 = 0 V

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017 to 2019, 2022. Supported for 2020.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Engine

1-2 shift error XT5_1_2_SHIFT_ERROR

  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

1-2 shift time XT5_1_2_SHIFT_TIME

  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2026.

2-3 shift error XT5_2_3_SHIFT_ERROR

  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

2-3 shift time XT5_2_3_SHIFT_TIME

  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

3-4 shift error XT5_3_4_SHIFT_ERROR

  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

3-4 shift time XT5_3_4_SHIFT_TIME

  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

14V auxiliary power module enable command XT5_14V_APM_ENABLEConfirmed

  • Service 22DID 1C39
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val128
Range
0 to 1.99
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

14V power module set point XT5_14V_POWER_MODULEConfirmed

  • Service 22DID 1C38
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×2051 = 0 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

14V power module set point voltage XT5_14V_POWER_MODULE_VConfirmed

  • Service 22DID 1C47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x00 = 0 → 010 = 0 V

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2018.

Active grille cold temperature mode XT5_ACTIVE_GRILLE_COLD_TConfirmed

  • Service 22DID 239B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Active grille shutter position XT5_ACTIVE_GRILLE_SHUTTER_POSConfirmed

  • Service 22DID 2366
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0xFF = 255 → 255×2051 = 100 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Active grille shutter position command XT5_ACTIVE_GRILLEConfirmed

  • Service 22DID 2364
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0xFF = 255 → 255×2051 = 100 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Air conditioning high side pressure XT5_AC_HIGH_SIDE_PConfirmed

  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2.02
Range
0 to 515.1 psi
Unit
psi

0x20 = 32 → 32×2.02 = 64.64 psi

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Air filter life remaining XT5_AIRFILT_LIFE

  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017 to 2019. Supported for 2020, 2022.

Air/fuel ratio, commanded XT5_AIR_FUEL_RAT_CMD

  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Ambient air temperature 2 XT5_AIR_TEMP_AMBIENT_2Confirmed

  • Service 22DID 232C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Axle torque driver requested XT5_AXLE_TQ_DRIVER_REQConfirmed

  • Service 22DID 2434
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val−22534
Range
-22534 to 43001 N·m
Unit
N·m

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Balance rate, cylinder 1 XT5_BALANCE_RATE_CYL_1

  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Balance rate, cylinder 2 XT5_BALANCE_RATE_CYL_2

  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Balance rate, cylinder 3 XT5_BALANCE_RATE_CYL_3

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Balance rate, cylinder 4 XT5_BALANCE_RATE_CYL_4

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Balance rate, cylinder 5 XT5_BALANCE_RATE_CYL_5

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Balance rate, cylinder 6 XT5_BALANCE_RATE_CYL_6

  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Barometric pressure, V6 XT5_BAROMETRIC_P_V6

  • Service 22DID 1251
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Barometric pressure, V8 XT5_BAROMETRIC_P_V8

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Boost pressure: actual XT5_BP_ACTConfirmed

  • Service 22DID 20E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

0x0000 = 0 → 0×10010000 = 0 kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Boost pressure: desired XT5_BP_DESConfirmed

  • Service 22DID 328A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

0x0000 = 0 → 0×10010000 = 0 kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Cabin A/C high side sensor voltage XT5_CABIN_AC_HIGH_SIDE_VConfirmed

  • Service 22DID 1144
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2019. Supported for 2020, 2022.

Calculated engine oil pressure XT5_EOP_CALCConfirmed

  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Calculated engine oil temperature XT5_EOT_CALCConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x5A = 90 → 90−40 = 50 °C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018. Supported for 2017, 2019 to 2020.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017 to 2019.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Cooling fan command XT5_COOLING_FAN_CMD

  • Service 22DID 3812
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Cooling fan motor command XT5_COOLING_FAN_MOTOR_CMDConfirmed

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Cruise control status XT5_CRUISE_CTRL_STATConfirmed

  • Service 22DID 2067
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2019. Supported for 2020, 2022.

Engine oil absolute pressure XT5_EOP_ABSConfirmed

  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

0x5D = 93 → 93×400100 = 372 kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil life remaining XT5_EO_LIFE_REMAINING

  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Engine oil pressure XT5_EOPConfirmed

  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

0x00 = 0 → 0×400100 = 0 kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil pressure XT5_EOP_DA11Confirmed

  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

0x00 = 0 → 0×400100 = 0 kPa

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil pressure 2 XT5_EOP_2Confirmed

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×35−21.6
Range
-21.6 to 131.39 psi
Unit
psi

0x23 = 35 → 35×35−21.6 = -0.6 psi

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil pressure control solenoid valve command XT5_EOP_CTRL_SOLENOID_VALVE_CMDConfirmed

  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil temperature XT5_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x7A = 122 → 122−40 = 82 °C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine oil temperature XT5_EOT_DA11Confirmed

  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Engine torque XT5_ENG_TQ

  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Engine torque XT5_ENG_TQ_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 N·m
Unit
N·m

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Evaporative emissions purge XT5_EVAPORATIVE

  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Exhaust gas recirculation duty cycle XT5_EGR_DUTYConfirmed

  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.55 = 0 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Exhaust gas recirculation voltage XT5_EGR_V

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel pressure FPSAE J1979Confirmed

  • Service 01PID 0A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3
Range
0 to 765 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Heated oxygen sensor XT5_HEATED_OXYGEN_SENSConfirmed

  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

0x00 = 0 → 0 mV

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Idle air control position XT5_IDLE_AIR_CTRL_POS

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Ignition input on/off/start XT5_IGN_INPUT_ON_OFFConfirmed

  • Service 22DID 20D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC0 = 192 → 192

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Ignition power mode XT5_IGN_POWER_MODEConfirmed

  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Injector duty cycle bank 1 XT5_INJECTOR_DUTY_CYCLE_BANK_1Confirmed

  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

0x0000 = 0 → 0×15010000 = 0 ms

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Injector duty cycle bank 2 XT5_INJECTOR_DUTY_CYCLE_BANK_2Confirmed

  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

0x0000 = 0 → 0×15010000 = 0 ms

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Injector pulse width, cylinder 1 XT5_INJ_WIDTH_CYL_1

  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2026.

Intake air temperature 2 XT5_IAT_2

  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake air temperature, bank 2, sensor 1 IAT_21SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake air temperature, bank 2, sensor 3 IAT_23SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2019 to 2020.

Knock retard XT5_KNOCK_RETARDConfirmed

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×22100
Range
0 to 56.1 °
Unit
°

0x00 = 0 → 0×22100 = 0 °

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Knock retard, alternate XT5_KNOCK_RETARD_ALT

  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2016 to 2026.

Knock sensor active counter XT5_KNOCK_SENS_ACTIVE

  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Last shift time XT5_LAST_SHIFT_TIME

  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2016 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Mass airflow sensor XT5_MAFConfirmed

Pelican can show this parameter as the mass air flow.

  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 g/s
Unit
g/s

0x0000 = 0 → 0×10010000 = 0 g/s

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

MIL cause XT5_MIL_CAUSEConfirmed

  • Service 22DID 135F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x15 = 21 → 21

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

MIL status XT5_MIL_STATConfirmed

  • Service 22DID 2020
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 1 XT5_MIS_HISTORY_1Confirmed

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 2 XT5_MIS_HISTORY_2Confirmed

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 3 XT5_MIS_HISTORY_3Confirmed

  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 4 XT5_MIS_HISTORY_4Confirmed

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 5 XT5_MIS_HISTORY_5Confirmed

  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfire history, cylinder 6 XT5_MIS_HISTORY_6Confirmed

  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 1 XT5_MISFIRES_C1_CURConfirmed

  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 2 XT5_MISFIRES_C2_CURConfirmed

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 3 XT5_MISFIRES_C3_CURConfirmed

  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 4 XT5_MISFIRES_C4_CURConfirmed

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 5 XT5_MISFIRES_C5_CURConfirmed

  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Misfires, current, cylinder 6 XT5_MISFIRES_C6_CURConfirmed

  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Outside air temperature XT5_AAT

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Pressure control solenoid current, actual XT5_P_CTRL_SOLENOID_ACT

  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Pressure control solenoid current, reference XT5_P_CTRL_SOLENOID

  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2016 to 2026.

Remaining oil life XT5_REMAINING_OIL_LIFE

  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Throttle position calculated XT5_THROTTLE_POS_CALCConfirmed

  • Service 22DID 2810
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×2051 = 0 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Total knock retard XT5_TOTAL_KNOCK_RETARDConfirmed

  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45100
Range
0 to 114.75 °
Unit
°

0x00 = 0 → 0×45100 = 0 °

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Total misfire XT5_TOTAL_MISFIREConfirmed

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission fluid temperature, variant 1 XT5_ATF_T_VAR_1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission fluid temperature, variant 7 XT5_ATF_T_VAR_7

  • Service 22DID 280D
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2018.

Internal

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Fuel

Ethanol content of fuel XT5_ETHANOL_CONTENT_FUELConfirmed

  • Service 22DID 0052
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x19 = 25 → 25×100255 = 9.803922 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Fuel consumption rate XT5_FUEL_RATE

  • Service 22DID 005E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50010000
Range
0 to 3276.75 L
Unit
L

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel injection, cylinder 1 XT5_FUEL_INJECTION_C1

  • Service 22DID 20AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel injection, cylinder 2 XT5_FUEL_INJECTION_C2

  • Service 22DID 1194
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2026.

Fuel injection, cylinder 3 XT5_FUEL_INJECTION_C3

  • Service 22DID 1195
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel injection, cylinder 4 XT5_FUEL_INJECTION_C4

  • Service 22DID 1196
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2026.

Fuel injection, cylinder 5 XT5_FUEL_INJECTION_C5

  • Service 22DID 1197
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel injection, cylinder 6 XT5_FUEL_INJECTION_C6

  • Service 22DID 1198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel remaining XT5_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xAD = 173 → 173×100255 = 67.843137 %

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2022. Supported for 2017, 2019 to 2020.

Fuel tank pressure XT5_FUEL_TANK_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val33333.33333
Range
0 to 1.96 psi
Unit
psi

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Fuel temperature XT5_FUEL_T

  • Service 22DID 3218
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Total fuel consumption rate XT5_TOTAL_FUEL_CONSUMPTION_RATE

  • Service 22DID 009D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Movement

Desired idle speed XT5_DES_IDLE_SPD

  • Service 22DID 1192
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5
Range
0 to 3187.5 rpm
Unit
rpm

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Torque converter clutch slip speed XT5_TQ_CONV_CLU_SLIP_SPD

  • Service 22DID 1991
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2018, 2022. Supported for 2017, 2019 to 2020.

Vehicle speed XT5_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 000D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016, 2020 to 2021, 2023 to 2026

Example reply from a 2022 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017 to 2019, 2022. In testing for 2016, 2020 to 2021, 2023 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2018. Supported for 2017, 2019 to 2020, 2022.

Tires

Left front tire pressure XT5_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 248E
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2016, 2020 to 2021, 2023 to 2026. Not supported for 2017 to 2019, 2022.

Left rear tire pressure XT5_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2491
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2016, 2020 to 2021, 2023 to 2026. Not supported for 2017 to 2019, 2022.

Right front tire pressure XT5_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 248F
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2016, 2020 to 2021, 2023 to 2026. Not supported for 2017 to 2019, 2022.

Right rear tire pressure XT5_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2490
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2016, 2020 to 2021, 2023 to 2026. Not supported for 2017 to 2019, 2022.

Transmission

Current gear XT5_CURRENT_GEAR_7E0

  • Service 22DID 199A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Current gear, variant 3 XT5_CURRENT_GEAR_VAR_3Confirmed

  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter position indicator XT5_SHIFTER_POSConfirmed

  • Service 22DID 1B1A
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−146
Range
-146 to 109
Unit
Number

0x77 = 119 → 119−146 = -27

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 1 duty cycle XT5_SHIFTER_X_POS_SENS_1Confirmed

  • Service 22DID 1B1B
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7C = 124 → 124

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 1 frequency XT5_SHIFTER_X_POS_SENS_1_FREQUENCYConfirmed

  • Service 22DID 1B1F
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x64 = 100 → 100

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 2 duty cycle XT5_SHIFTER_X_POS_SENS_2Confirmed

  • Service 22DID 1B1D
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x84 = 132 → 132

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 2 frequency XT5_SHIFTER_X_POS_SENS_2_FREQUENCYConfirmed

  • Service 22DID 1B21
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x64 = 100 → 100

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 1 duty cycle XT5_SHIFTER_Y_POS_SENS_1Confirmed

  • Service 22DID 1B1C
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x95 = 149 → 149

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 1 frequency XT5_SHIFTER_Y_POS_SENS_1_FREQUENCYConfirmed

  • Service 22DID 1B20
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 2 duty cycle XT5_SHIFTER_Y_POS_SENS_2Confirmed

  • Service 22DID 1B1E
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x6C = 108 → 108

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 2 frequency XT5_SHIFTER_Y_POS_SENS_2_FREQUENCYConfirmed

  • Service 22DID 1B22
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x64 = 100 → 100

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission park position switch 1 XT5_TRANS_PARK_POS_1Confirmed

  • Service 22DID 1B23
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xA3 = 163 → 163

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission park position switch 2 XT5_TRANS_PARK_POS_2Confirmed

  • Service 22DID 1B24
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xA3 = 163 → 163

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission shift interlock switch 1 XT5_TRANS_SHIFT_1Confirmed

  • Service 22DID 1B25
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC2 = 194 → 194

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission shift interlock switch 2 XT5_TRANS_SHIFT_2Confirmed

  • Service 22DID 1B26
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC3 = 195 → 195

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Trips

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.