Chevrolet Corvette

Parameters

The Chevrolet Corvette has 218 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature CORVETTE_EOT_DA11_2_2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x41 = 65 → 65−40 = 25 °C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Charge air cooler temperature sensor 1 CORVETTE_CHARGE_AIR_COOLER_T_SNS_1

  • Service 22DID 30AD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Charge air cooler temperature sensor 2 CORVETTE_CHARGE_AIR_COOLER_T_SNS_2

  • Service 22DID 30AE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Control module voltage CORVETTE_M_CTRL_MODULE_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0042
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 1996 to 2019.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2015, 2023, 2025. Supported for 2020 to 2021, 2024.

Ignition 1 voltage CORVETTE_IGN_1_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1996 to 2019.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2020 to 2021, 2023.

Clocks

Time since engine start CORVETTE_RUNTM

  • Service 22DID 11A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2008 to 2019.

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023 to 2024.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Steering wheel angle CORVETTE_STEER_ANGLEConfirmed

  • Service 22DID 4C2D
  • ModuleDA28
  • Every100 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×22010000
Range
-720.896 to 720.874 °
Unit
°

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2015, 2023 to 2025. Supported for 2006 to 2007, 2012, 2020 to 2021.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Engine

1-2 shift error CORVETTE_1_2_SHIFT_ERROR

  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

1-2 shift time CORVETTE_1_2_SHIFT_TIME

  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

2-3 shift error CORVETTE_2_3_SHIFT_ERROR

  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

2-3 shift time CORVETTE_2_3_SHIFT_TIME

  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

3-4 shift error CORVETTE_3_4_SHIFT_ERROR

  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

3-4 shift time CORVETTE_3_4_SHIFT_TIME

  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2024. Supported for 2020 to 2021, 2023, 2025.

Air conditioning high side pressure CORVETTE_AC_HIGH_SIDE_P

  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2.02
Range
0 to 515.1 psi
Unit
psi

In testing for 1996 to 2019.

Air filter life remaining CORVETTE_AIRFILT_LIFEConfirmed

  • Service 22DID 36A7
  • ModuleDA11
  • Every30 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Air filter life remaining CORVETTE_AIRFILT_LIFE_7E0

  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Air/fuel ratio, commanded CORVETTE_AIR_FUEL_RAT_CMD

  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 1 CORVETTE_BALANCE_RATE_CYL_1

  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 2 CORVETTE_BALANCE_RATE_CYL_2

  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 3 CORVETTE_BALANCE_RATE_CYL_3

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 4 CORVETTE_BALANCE_RATE_CYL_4

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 5 CORVETTE_BALANCE_RATE_CYL_5

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 6 CORVETTE_BALANCE_RATE_CYL_6

  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 7 CORVETTE_BALANCE_RATE_CYL_7

  • Service 22DID 1635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Balance rate, cylinder 8 CORVETTE_BALANCE_RATE_CYL_8

  • Service 22DID 1636
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 1996 to 2019.

Barometric pressure, V8 CORVETTE_BAROMETRIC_P_V8

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1996 to 2019.

Boost pressure, actual CORVETTE_BP_ACTConfirmed

  • Service 22DID 20E3
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Boost pressure, actual CORVETTE_BP_ACT_7E0

  • Service 22DID 20E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1996 to 2019.

Boost pressure, desired CORVETTE_BP_DES

  • Service 22DID 328A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1996 to 2019.

Brake pressure CORVETTE_BPConfirmed

  • Service 22DID 4A7C
  • ModuleDA28
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×100−1000
Range
-13800 to 11700 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Calculated engine oil pressure CORVETTE_EOP_CALC

  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 1996 to 2019.

Calculated engine oil temperature CORVETTE_EOT_CALC

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2024 to 2025. Supported for 2020 to 2021, 2023.

Cooling fan command CORVETTE_COOLING_FAN_CMD

  • Service 22DID 3812
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Cooling fan motor command CORVETTE_COOLING_FAN_MOTOR_CMD

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Engine oil absolute pressure CORVETTE_EOP_ABS

  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 1996 to 2019.

Engine oil absolute pressure sensor CORVETTE_EO_APConfirmed

  • Service 22DID 2344
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Engine oil life remaining CORVETTE_EO_LIFE_REMAINING

  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Engine oil life remaining CORVETTE_EOLConfirmed

  • Service 22DID 4DC0
  • ModuleDA11
  • Every30 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Engine oil pressure CORVETTE_EOP

  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 1996 to 2019.

Engine oil pressure CORVETTE_EOP_DA11

  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 1996 to 2019.

Engine oil pressure CORVETTE_EOP_DA11_2Confirmed

  • Service 22DID 1470
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

0x00 = 0 → 0×400100 = 0 kPa

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Engine oil pressure 2 CORVETTE_EOP_2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×35−21.6
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 1996 to 2019.

Engine oil pressure control solenoid valve command CORVETTE_EOP_CTRL_SOLENOID_VALVE_CMD

  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2019.

Engine oil pressure, actual CORVETTE_EOP_ACTConfirmed

  • Service 22DID 2345
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Engine oil temperature CORVETTE_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 153E
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Engine oil temperature CORVETTE_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Engine oil temperature CORVETTE_EOT_DA11

  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Engine oil temperature CORVETTE_EOT_DA11_2_2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x41 = 65 → 65−40 = 25 °C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023, 2025.

Engine torque CORVETTE_ENG_TQ

  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2019.

Engine torque CORVETTE_ENG_TQ_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 N·m
Unit
N·m

In testing for 1996 to 2019.

Evaporative emissions purge CORVETTE_EVAPORATIVE

  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Heated oxygen sensor CORVETTE_HEATED_OXYGEN_SENS

  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 1996 to 2019.

Idle air control position CORVETTE_IDLE_AIR_CTRL_POS

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Injector duty cycle bank 1 CORVETTE_INJECTOR_DUTY_CYCLE_BANK_1

  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 1996 to 2019.

Injector duty cycle bank 2 CORVETTE_INJECTOR_DUTY_CYCLE_BANK_2

  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 1996 to 2019.

Injector pulse width, cylinder 1 CORVETTE_INJ_WIDTH_CYL_1

  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Injector pulse width, cylinder 7 CORVETTE_INJ_WIDTH_CYL_7

  • Service 22DID 1199
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Injector pulse width, cylinder 8 CORVETTE_INJ_WIDTH_CYL_8

  • Service 22DID 129A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Intake air temperature 2 CORVETTE_IAT_2

  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Knock retard CORVETTE_KNOCK_RETARD

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×22100
Range
0 to 56.1 °
Unit
°

In testing for 1996 to 2019.

Knock retard, alternate CORVETTE_KNOCK_RETARD_ALT

  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1996 to 2019.

Knock sensor active counter CORVETTE_KNOCK_SENS_ACTIVE

  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Last shift time CORVETTE_LAST_SHIFT_TIME

  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 1996 to 2019.

Mass airflow sensor CORVETTE_MAFConfirmed

  • Service 22DID 0010
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Mass airflow sensor CORVETTE_MAF_7E0

  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1996 to 2019.

Misfire current, cylinder 7 CORVETTE_MIS_CURRENT_7

  • Service 22DID 11EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfire current, cylinder 8 CORVETTE_MIS_CURRENT_8

  • Service 22DID 11ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 1 CORVETTE_MIS_HISTORY_1

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 2 CORVETTE_MIS_HISTORY_2

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 3 CORVETTE_MIS_HISTORY_3

  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 4 CORVETTE_MIS_HISTORY_4

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 5 CORVETTE_MIS_HISTORY_5

  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 6 CORVETTE_MIS_HISTORY_6

  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 7 CORVETTE_MIS_HISTORY_7

  • Service 22DID 11FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfire history, cylinder 8 CORVETTE_MIS_HISTORY_8

  • Service 22DID 11FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 1 CORVETTE_MIS_1Confirmed

  • Service 22DID 1206
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 1 CORVETTE_MISFIRES_C1_CUR

  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 2 CORVETTE_MIS_2Confirmed

  • Service 22DID 1205
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 2 CORVETTE_MISFIRES_C2_CUR

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 3 CORVETTE_MIS_3Confirmed

  • Service 22DID 1207
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 3 CORVETTE_MISFIRES_C3_CUR

  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 4 CORVETTE_MIS_4Confirmed

  • Service 22DID 1208
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 4 CORVETTE_MISFIRES_C4_CUR

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 5 CORVETTE_MIS_5Confirmed

  • Service 22DID 11EA
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 5 CORVETTE_MISFIRES_C5_CUR

  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 6 CORVETTE_MIS_6Confirmed

  • Service 22DID 11EB
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Misfires, current, cylinder 6 CORVETTE_MISFIRES_C6_CUR

  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Misfires, current, cylinder 7 CORVETTE_MISFIRES_C7_CURConfirmed

  • Service 22DID 11EC
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Misfires, current, cylinder 8 CORVETTE_MISFIRES_C8_CURConfirmed

  • Service 22DID 11ED
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Outside air temperature CORVETTE_AAT

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Particulate filter pressure CORVETTE_DPF_PRESSConfirmed

  • Service 22DID 34D8
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Pressure control solenoid current, actual CORVETTE_P_CTRL_SOLENOID_ACT

  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2019.

Pressure control solenoid current, reference CORVETTE_P_CTRL_SOLENOID

  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2019.

Remaining oil life CORVETTE_REMAINING_OIL_LIFE

  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2019.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023 to 2024.

Total knock retard CORVETTE_TOTAL_KNOCK_RETARD

  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45100
Range
0 to 114.75 °
Unit
°

In testing for 1996 to 2019.

Total misfire CORVETTE_TOTAL_MISFIRE

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Transmission fluid temperature CORVETTE_TFTConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • ModuleDA18
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Transmission fluid temperature, variant 1 CORVETTE_ATF_T_VAR_1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Transmission fluid temperature, variant 3 CORVETTE_ATF_T_VAR_3

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

Transmission fluid temperature, variant 8 CORVETTE_ATF_T_VAR_8

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 280D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2019.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2024 to 2025. Supported for 2020.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2024 to 2025. Supported for 2020.

Fuel

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2015, 2025.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2015, 2025.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2025.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2025.

Ethanol content of fuel CORVETTE_ETHANOL_CONTENT_FUEL

  • Service 22DID 0052
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Fuel consumption rate CORVETTE_FUEL_RATEConfirmed

  • Service 22DID 005E
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50010000
Range
0 to 3276.75 L
Unit
L

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Fuel consumption rate CORVETTE_FUEL_RATE_7E0

  • Service 22DID 005E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50010000
Range
0 to 3276.75 L
Unit
L

In testing for 1996 to 2019.

Fuel injection, cylinder 1 CORVETTE_FUEL_INJECTION_C1

  • Service 22DID 20AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 2 CORVETTE_FUEL_INJECTION_C2

  • Service 22DID 1194
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 2 CORVETTE_FUEL_INJECTION_C2_DA11

  • Service 22DID 1194
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 3 CORVETTE_FUEL_INJECTION_C3

  • Service 22DID 1195
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 3 CORVETTE_FUEL_INJECTION_C3_DA11

  • Service 22DID 1195
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 4 CORVETTE_FUEL_INJECTION_C4

  • Service 22DID 1196
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 4 CORVETTE_FUEL_INJECTION_C4_DA11

  • Service 22DID 1196
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 5 CORVETTE_FUEL_INJECTION_C5

  • Service 22DID 1197
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 5 CORVETTE_FUEL_INJECTION_C5_DA11

  • Service 22DID 1197
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 6 CORVETTE_FUEL_INJECTION_C6

  • Service 22DID 1198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 1996 to 2019.

Fuel injection, cylinder 6 CORVETTE_FUEL_INJECTION_C6_DA11

  • Service 22DID 1198
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 7 CORVETTE_FUEL_INJECTION_C7

  • Service 22DID 1199
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection, cylinder 8 CORVETTE_FUEL_INJECTION_C8

  • Service 22DID 20B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 1996 to 2019.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2015, 2025.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2015, 2025.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2025.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2025.

Fuel remaining CORVETTE_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • ModuleDA11
  • Every1 s
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Fuel remaining CORVETTE_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2019.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2025. Supported for 2006 to 2007, 2012, 2020 to 2021, 2023 to 2024.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2025. Supported for 2006 to 2007, 2012, 2020 to 2021, 2023 to 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2015, 2023, 2025. Supported for 2006 to 2007, 2012, 2020 to 2021, 2024.

Fuel tank pressure CORVETTE_FUEL_TANK_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val33333.33333
Range
0 to 1.96 psi
Unit
psi

In testing for 1996 to 2019.

Fuel temperature CORVETTE_FUEL_T

  • Service 22DID 3218
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 1996 to 2019.

Fuel temperature CORVETTE_FUEL_T_DA11

  • Service 22DID 3218
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Total fuel consumption rate CORVETTE_TOTAL_FUEL_CONSUMPTION_RATE

  • Service 22DID 009D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 1996 to 2019.

Total fuel consumption rate CORVETTE_TOTAL_FUEL_CONSUMPTION_RATE_DA11Confirmed

  • Service 22DID 009D
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing for 1996 to 2023, 2025 to 2026

Example reply from a 2024 Chevrolet Corvette.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

0x0000 = 0 → 0×20010000 = 0 g/s

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2025.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2025.

Movement

Desired idle speed CORVETTE_DES_IDLE_SPD

  • Service 22DID 1192
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5
Range
0 to 3187.5 rpm
Unit
rpm

In testing for 1996 to 2019.

Front left wheel speed CORVETTE_TIRE_FL_VSSConfirmed

  • Service 22DID 4A7A
  • ModuleDA28
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Front right wheel speed CORVETTE_TIRE_FR_VSSConfirmed

  • Service 22DID 4A7A
  • ModuleDA28
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Rear left wheel speed CORVETTE_TIRE_RL_VSSConfirmed

  • Service 22DID 4A7A
  • ModuleDA28
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Rear right wheel speed CORVETTE_TIRE_RR_VSSConfirmed

  • Service 22DID 4A7A
  • ModuleDA28
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Torque converter clutch slip speed CORVETTE_TQ_CONV_CLU_SLIP_SPD

  • Service 22DID 1991
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 1996 to 2019.

Vehicle speed CORVETTE_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 000D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2011, 2013 to 2026

Example reply from a 2012 Chevrolet Corvette.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2012. In testing for 1996 to 2011, 2013 to 2019. Not supported for 2025.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2015, 2023 to 2025. Supported for 2006 to 2007, 2012, 2020 to 2021.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023 to 2024.

Orientation

Lateral acceleration CORVETTE_LAT_GConfirmed

  • Service 22DID 4C2F
  • ModuleDA28
  • Every100 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15.9279672510000
Range
-52 to 52 g
Unit
g

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Longitudinal acceleration CORVETTE_LNG_GConfirmed

  • Service 22DID 4C30
  • ModuleDA28
  • Every100 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15.9279672510000
Range
-52 to 52 g
Unit
g

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Tires

Front left tire pressure CORVETTE_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 5005
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 1996 to 2019.

Front left tire pressure CORVETTE_TP_FL_DA40

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 5005
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Front left tire sensor ID CORVETTE_TID_FL

  • Service 22DID 4005
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 1996 to 2019.

Front left tire sensor ID CORVETTE_TID_FL_DA40

  • Service 22DID 4005
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Front right tire pressure CORVETTE_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 5006
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 1996 to 2019.

Front right tire pressure CORVETTE_TP_FR_DA40Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 5006
  • ModuleDA40 → 40
  • Every15 s
  • Testing for 1996 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Front right tire sensor ID CORVETTE_TID_FR

  • Service 22DID 4006
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 1996 to 2019.

Front right tire sensor ID CORVETTE_TID_FR_DA40

  • Service 22DID 4006
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Left front tire pressure CORVETTE_TP_FL_7E0

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 248E
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2013 to 2019. Not supported for 2012, 2025.

Left rear tire pressure CORVETTE_TP_RL_7E0

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2491
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2013 to 2019. Not supported for 2012, 2025.

Rear left tire pressure CORVETTE_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 5008
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 1996 to 2019.

Rear left tire pressure CORVETTE_TP_RL_DA40

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 5008
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Rear left tire sensor ID CORVETTE_TID_RL

  • Service 22DID 4008
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 1996 to 2019.

Rear left tire sensor ID CORVETTE_TID_RL_DA40

  • Service 22DID 4008
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Rear right tire pressure CORVETTE_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 5007
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 1996 to 2019.

Rear right tire pressure CORVETTE_TP_RR_DA40Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 5007
  • ModuleDA40 → 40
  • Every15 s
  • Testing for 1996 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Rear right tire sensor ID CORVETTE_TID_RR

  • Service 22DID 4007
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 1996 to 2019.

Rear right tire sensor ID CORVETTE_TID_RR_DA40

  • Service 22DID 4007
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Right front tire pressure CORVETTE_TP_FR_7E0

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 248F
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2013 to 2019. Not supported for 2012, 2025.

Right rear tire pressure CORVETTE_TP_RR_7E0

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2490
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2013 to 2019. Not supported for 2012, 2025.

Transmission

Current gear CORVETTE_CURRENT_GEAR_7E0

  • Service 22DID 199A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Current gear, variant 3 CORVETTE_CURRENT_GEAR_VAR_3

  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2019.

Shift gear CORVETTE_GEARConfirmed

  • Service 22DID 1B30
  • ModuleDA18
  • Every250 ms
  • Testing for 1996 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1NEUTRALNeutral
2PARKPark
3REVERSEReverse
4D1Drive, gear 1
5D2Drive, gear 2
6D3Drive, gear 3
7D4Drive, gear 4
8D5Drive, gear 5
9D6Drive, gear 6
10D7Drive, gear 7
11D8Drive, gear 8

Confirmed for 2024 to 2025. In testing for 1996 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.

Trips

Odometer CORVETTE_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 448F
  • ModuleDA1A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×156.2510000
Range
0 to 1000000 km
Unit
km

In testing for 1996 to 2014, 2016 to 2022. Not supported for 2015, 2023 to 2025.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2023, 2025.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.