Dodge Charger

Parameters

The Dodge Charger has 222 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission fluid temperature CHARGER_ATF_T_3RDGEN_V2Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 5C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2026

Example reply from a 2006 Dodge Charger.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x4A = 74 → 74−50 = 24 °C

Confirmed for 2006. In testing for 2007 to 2012, 2014. Not supported for 2013, 2015, 2018 to 2019, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery temperature CHARGER_BAT_T

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Battery voltage, BCM CHARGER_BATT_V_BCMConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1004
  • ModuleDA40 → 40
  • Every30 s
  • Testing for 2006 to 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2026. In testing for 2024 to 2025.

Charge air cooler outlet temperature CHARGER_CHG_AIR_COOLER_TConfirmed

  • Service 21PID B4
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 96 to 111 of the reply, 16 bits.

Formula
val×9320+32
Range
0 to 1875 °F
Unit
°F

0x014B = 331 → 331×9320+32 = 41.309375 °F

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Charge air temperature CHARGER_CHG_AIR_TConfirmed

  • Service 22DID 1250
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−83
Range
-83 to 376 °F
Unit
°F

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018 to 2019, 2021. Supported for 2011 to 2012, 2015 to 2017, 2023, 2026.

Required fuel charge, cylinder 1 CHARGER_REQUIRED_FUEL_CHG_1Confirmed

  • Service 22DID 02B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Required fuel charge, cylinder 2 CHARGER_REQUIRED_FUEL_CHG_2Confirmed

  • Service 22DID 02B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x011A = 282 → 28264 = 4.40625

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Required fuel charge, cylinder 3 CHARGER_REQUIRED_FUEL_CHG_3Confirmed

  • Service 22DID 02B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x0118 = 280 → 28064 = 4.375

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Required fuel charge, cylinder 4 CHARGER_REQUIRED_FUEL_CHG_4Confirmed

  • Service 22DID 02B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x011E = 286 → 28664 = 4.46875

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2018 to 2019. Supported for 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2015, 2019. Supported for 2006, 2011 to 2013, 2016 to 2018, 2021, 2023, 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019. Supported for 2026.

Brake booster pressure CHARGER_BRAKE_BOOSTER_PConfirmed

  • Service 22DID 0944
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 kPa
Unit
kPa

0x167B = 5755 → 5755100 = 57.55 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

High beam mode CHARGER_HIGHBEAMS_MODEConfirmed

  • Service 22DID 032D
  • Module763 → 4E3
  • Every250 ms
  • Testing for 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states

0b0000 = 0 → OFF

States
Raw valueStateMeaning
0OFFOff
1ONOn
2HELDHeld

Confirmed for 2015 to 2016, 2018 to 2019, 2021. In testing for 2017, 2020, 2022 to 2023. Not supported for 2006, 2013, 2026.

High beams CHARGER_HIGHBEAMS_ONConfirmed

  • Service 22DID 032D
  • Module763 → 4E3
  • Every250 ms
  • Testing for 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2015 to 2016, 2018 to 2019, 2021. In testing for 2017, 2020, 2022 to 2023. Not supported for 2006, 2013, 2026.

Rear wiper CHARGER_REAR_WIPERConfirmed

  • Service 22DID 032D
  • Module763 → 4E3
  • Every250 ms
  • Testing for 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bits 12 to 15 of the reply, 4 bits.

Unit
Named states

0b0000 = 0 → OFF

States
Raw valueStateMeaning
0OFFOff
1SPRAYSpray
2AUTOAuto
4ONOn

Confirmed for 2015 to 2016, 2018 to 2019, 2021. In testing for 2017, 2020, 2022 to 2023. Not supported for 2006, 2013, 2026.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019. Supported for 2026.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019. Supported for 2026.

Doors

Driver door open CHARGER_DRIVER_DOOR_OPENConfirmed

  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing for 2006 to 2025

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Passenger door open CHARGER_PASSENGER_DOOR_OPENConfirmed

  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing for 2006 to 2025

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Rear left door open CHARGER_RLD_OPENConfirmed

  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing for 2006 to 2025

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Rear right door open CHARGER_RRD_OPENConfirmed

  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing for 2006 to 2025

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Trunk open CHARGER_TRUNK_OPENConfirmed

  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing for 2006 to 2025

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2006, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026. Supported for 2011 to 2013, 2017.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Distance with water in fuel warning CHARGER_WATER_FUEL_DISTConfirmed

  • Service 22DID 1009
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2006 to 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2026. In testing for 2007 to 2015, 2017, 2020 to 2025. Not supported for 2006, 2016, 2018 to 2019.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2016, 2018 to 2019. Supported for 2011, 2026.

Air conditioning high side pressure CHARGER_AC_HIGH_SIDE_PConfirmed

  • Service 22DID 0329
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14
Range
0 to 3570 kPa
Unit
kPa

0x1A = 26 → 26×14 = 364 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Air conditioning high side pressure CHARGER_AC_HIGH_SIDE_P_7E0

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val55
Range
0 to 1191 psi
Unit
psi

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Ambient air temperature CHARGER_AAT_7E0

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Ambient temperature CHARGER_AATConfirmed

  • Service 22DID 0127
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−83
Range
-83 to 376 °F
Unit
°F

0x46 = 70 → 70×95−83 = 43 °F

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Automatic transmission fluid temperature CHARGER_ATF_T_3RDGEN_V2Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 5C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2007 to 2026

Example reply from a 2006 Dodge Charger.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x4A = 74 → 74−50 = 24 °C

Confirmed for 2006. In testing for 2007 to 2012, 2014. Not supported for 2013, 2015, 2018 to 2019, 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Barometric pressure CHARGER_BAROMETRIC_PConfirmed

  • Service 22DID 0109
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

0x01EE = 494 → 4945 = 98.8 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006, 2016, 2018 to 2019, 2026. Supported for 2011 to 2013, 2015, 2017, 2021, 2023.

Catalyst modeled temperature CHARGER_CAT_MODEL_TConfirmed

  • Service 22DID 012B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

0x026C = 620 → 620 °C

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2006, 2016, 2018 to 2019, 2026.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2006, 2016, 2018 to 2019, 2026. Supported for 2011 to 2013, 2015, 2017, 2021, 2023.

Engine oil pressure CHARGER_EOPConfirmed

  • Service 22DID 022A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2950
Range
0 to 147.8999 psi
Unit
psi

0x51 = 81 → 81×2950 = 46.98 psi

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Engine oil temperature CHARGER_EOT_212D

Pelican can show this parameter as the engine oil temperature.

  • Service 21PID 2D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×95−83
Range
-83 to 376 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2023. Not supported for 2016.

Engine operational status CHARGER_ENGINE_STATUSConfirmed

  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2006 to 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2026. In testing for 2007 to 2015, 2017, 2020 to 2025. Not supported for 2006, 2016, 2018 to 2019.

Engine RPM CHARGER_RPM_ECUConfirmed

  • Service 22DID 1000
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2006 to 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

Confirmed for 2026. In testing for 2007 to 2015, 2017, 2020 to 2025. Not supported for 2006, 2016, 2018 to 2019.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2016, 2018 to 2019. Supported for 2006, 2011 to 2013, 2015, 2017, 2021, 2023, 2026.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2018 to 2019. Supported for 2012 to 2013, 2015 to 2017, 2021, 2023, 2026.

Exhaust camshaft 1 to crankshaft offset CHARGER_EXH_CAM_1_OFFSET

  • Service 22DID 061B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Fuel pressure FPSAE J1979Confirmed

  • Service 01PID 0A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3
Range
0 to 765 kPa
Unit
kPa

Confirmed for 2019. Supported for 2018, 2021, 2026.

Injector pulse width, cylinder 1 CHARGER_INJ_WIDTH_CYL_1Confirmed

  • Service 22DID 0234
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

0x00000000 = 0 → 01000 = 0 ms

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Injector pulse width, cylinder 2 CHARGER_INJ_WIDTH_CYL_2Confirmed

  • Service 22DID 0235
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

0x00000000 = 0 → 01000 = 0 ms

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Injector pulse width, cylinder 3 CHARGER_INJ_WIDTH_CYL_3Confirmed

  • Service 22DID 0236
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

0x00000000 = 0 → 01000 = 0 ms

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Injector pulse width, cylinder 4 CHARGER_INJ_WIDTH_CYL_4Confirmed

  • Service 22DID 0237
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

0x00000000 = 0 → 01000 = 0 ms

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019.

Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019.

Intake camshaft 1 to crankshaft offset CHARGER_INT_CAM_1_OFFSETConfirmed

  • Service 22DID 06C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0058 = 88 → 8810 = 8.8 °

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Intake manifold air pressure CHARGER_MAPConfirmed

  • Service 22DID 0174
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

0x0061 = 97 → 975 = 19.4 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Intake manifold air temperature CHARGER_IAT_01FFConfirmed

  • Service 22DID 01FF
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−64
Range
-64 to 191 °C
Unit
°C

0x50 = 80 → 80−64 = 16 °C

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Intake manifold air temperature CHARGER_IAT_1935

  • Service 22DID 1935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 65495 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Intake manifold air temperature CHARGER_IAT_70B8

  • Service 22DID 70B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0198412698−40
Range
-40 to 1260.2976 °C
Unit
°C

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Knock sensor 1 CHARGER_KNOCK_SENS_1Confirmed

  • Service 22DID 01A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val13107
Range
0 to 5 V
Unit
V

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Knock sensor 2 CHARGER_KNOCK_SENS_2Confirmed

  • Service 22DID 01AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val13107
Range
0 to 5 V
Unit
V

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Line pressure CHARGER_LINE_P

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Line pressure duty cycle CHARGER_LINE_P_DUTY

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val655
Range
0 to 100 %
Unit
%

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Multi-displacement system active CHARGER_MDS_ACTIVEConfirmed

  • Service 22DID 0ECA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Short term knock retard CHARGER_SHORT_TERM_KNOCK

  • Service 22DID 01AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °
Unit
°

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Throttle inlet air temperature filtered CHARGER_THROTTLE_INLET_AIR_T

  • Service 22DID 14B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−64
Range
-64 to 191 °C
Unit
°C

In testing for 2006 to 2015, 2017 to 2023. Not supported for 2016.

Throttle inlet pressure CHARGER_THROTTLE_INLET_PConfirmed

  • Service 22DID 1247
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val160
Range
0 to 409.5937 kPa
Unit
kPa

0x3D9E = 15774 → 15774160 = 98.5875 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Transmission main cylinder pressure CHARGER_MAIN_CYL_PConfirmed

  • Service 22DID 5034
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 bar
Unit
bar

0x0000 = 0 → 010−40 = -40 bar

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2018 to 2019.

Variable valve timing oil pressure CHARGER_VARIABLE_VLV_TIM_OIL_PConfirmed

  • Service 22DID 069E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

0x3F = 63 → 63×4 = 252 kPa

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Variable valve timing oil temperature CHARGER_VARIABLE_VLV_TIM_OIL_TConfirmed

  • Service 22DID 069F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−64
Range
-64 to 191 °C
Unit
°C

0x6B = 107 → 107−64 = 43 °C

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Internal

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2018, 2026.

O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2018, 2026.

Fuel

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2026.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2026.

Fuel level CHARGER_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val256
Range
0 to 255 %
Unit
%

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Fuel level input CHARGER_FLI_INPUTConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 0227
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xBE = 190 → 190×100255 = 74.509804 %

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel mass, cylinder 1 CHARGER_FUEL_MASS_CYL_1Confirmed

  • Service 22DID 0255
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x0000 = 0 → 064 = 0

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel mass, cylinder 2 CHARGER_FUEL_MASS_CYL_2Confirmed

  • Service 22DID 0256
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x0000 = 0 → 064 = 0

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel mass, cylinder 3 CHARGER_FUEL_MASS_CYL_3Confirmed

  • Service 22DID 0257
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel mass, cylinder 4 CHARGER_FUEL_MASS_CYL_4Confirmed

  • Service 22DID 0258
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843
Unit
Raw value

0x0000 = 0 → 064 = 0

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel pressure sensor, 1000's psi CHARGER_FUEL_P_SENS_1000_SConfirmed

  • Service 21PID B4
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val552
Range
0 to 118 psi
Unit
psi

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2018 to 2019, 2026. Supported for 2006, 2011 to 2013, 2016 to 2017, 2021, 2023.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2018 to 2019, 2026. Supported for 2006, 2011 to 2013, 2016 to 2017, 2021, 2023.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006, 2015, 2018 to 2019, 2021, 2023, 2026. Supported for 2011 to 2013, 2016 to 2017.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2026.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Movement

Odometer at last excess speed event CHARGER_ODO_LAST_OVERSPEED

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Output shaft speed CHARGER_OUTPUT_SHFT_SPD

  • Service 21PID CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2006 to 2015, 2017 to 2023. Supported for 2016.

Radiator fan speed CHARGER_RADIATOR_FAN_SPDConfirmed

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 80 to 87 of the reply, 8 bits.

Formula
val×520
Range
0 to 132600 rpm
Unit
rpm

0x00 = 0 → 0×520 = 0 rpm

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2015 to 2016, 2018 to 2019, 2021, 2023. Supported for 2006, 2011 to 2013, 2017, 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.

Tires

Front left tire pressure CHARGER_TP_FL_7DA

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID A020
  • Module7DA
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15414250
Range
0 to 92 psi
Unit
psi

In testing for 2006 to 2015. Not supported for 2016, 2018.

Front left tire pressure invalid? CHARGER_TP_FL_INVALIDConfirmed

  • Service 22DID 012F
  • ModuleDAC7 → C7
  • Every5 s
  • Testing for 2006 to 2025

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Front left tire sensor id CHARGER_TID_FLConfirmed

  • Service 22DID 0123
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing for 2006 to 2025

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

Confirmed for 2026. In testing for 2024 to 2025.

Front left wheel speed CHARGER_FL_WHL_SPDConfirmed

  • Service 22DID 1737
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 km/h
Unit
km/h

0x0000 = 0 → 064 = 0 km/h

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Front right tire pressure CHARGER_TP_FR_7DA

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID A021
  • Module7DA
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15414250
Range
0 to 92 psi
Unit
psi

In testing for 2006 to 2015. Not supported for 2016, 2018.

Front right tire pressure invalid? CHARGER_TP_FR_INVALIDConfirmed

  • Service 22DID 012F
  • ModuleDAC7 → C7
  • Every5 s
  • Testing for 2006 to 2025

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Front right tire sensor id CHARGER_TID_FRConfirmed

  • Service 22DID 0124
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing for 2006 to 2025

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

Confirmed for 2026. In testing for 2024 to 2025.

Front right wheel speed CHARGER_FR_WHL_SPDConfirmed

  • Service 22DID 1738
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 km/h
Unit
km/h

0x00C0 = 192 → 19264 = 3 km/h

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Rear left tire pressure CHARGER_TP_RL_7DA

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID A022
  • Module7DA
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15414250
Range
0 to 92 psi
Unit
psi

In testing for 2006 to 2015. Not supported for 2016, 2018.

Rear left tire pressure invalid? CHARGER_TP_RL_INVALIDConfirmed

  • Service 22DID 012F
  • ModuleDAC7 → C7
  • Every5 s
  • Testing for 2006 to 2025

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Rear left tire sensor id CHARGER_TID_RLConfirmed

  • Service 22DID 0125
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing for 2006 to 2025

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

Confirmed for 2026. In testing for 2024 to 2025.

Rear left wheel speed CHARGER_RL_WHL_SPDConfirmed

  • Service 22DID 1739
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 km/h
Unit
km/h

0x01AC = 428 → 42864 = 6.6875 km/h

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Rear right tire pressure CHARGER_TP_RR_7DA

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID A023
  • Module7DA
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15414250
Range
0 to 92 psi
Unit
psi

In testing for 2006 to 2015. Not supported for 2016, 2018.

Rear right tire pressure invalid? CHARGER_TP_RR_INVALIDConfirmed

  • Service 22DID 012F
  • ModuleDAC7 → C7
  • Every5 s
  • Testing for 2006 to 2025

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2024 to 2025.

Rear right tire sensor id CHARGER_TID_RRConfirmed

  • Service 22DID 0127
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing for 2006 to 2025

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

Confirmed for 2026. In testing for 2024 to 2025.

Rear right wheel speed CHARGER_RR_WHL_SPDConfirmed

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 km/h
Unit
km/h

0x0000 = 0 → 064 = 0 km/h

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Tire size CHARGER_TIRE_SIZEConfirmed

  • Service 22DID 2024
  • ModuleDA18 → 18
  • Every86400 s
  • Testing for 2006 to 2025

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

Confirmed for 2026. In testing for 2024 to 2025.

Transmission

Current gear CHARGER_CURRENT_GEAR

  • Service 22DID 3C22
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Current gear CHARGER_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 5503
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2012, 2014, 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states

0b0001 = 1 → 1

States
Raw valueStateMeaning
0NEUTRALNeutral
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear
11REARRear
13PARKPark

Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021. In testing for 2011 to 2012, 2014, 2017, 2020, 2022 to 2023. Not supported for 2006, 2026.

Current gear CHARGER_GEAR_CURRENTConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every250 ms
  • Testing for 2006 to 2025

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2026. In testing for 2024 to 2025.

Desired gear CHARGER_GEAR_DESIREDConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every250 ms
  • Testing for 2006 to 2025

Bits 0 to 3 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2026. In testing for 2024 to 2025.

Target gear CHARGER_GEAR_TARGETConfirmed

The target gear.

  • Service 22DID 5504
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2012, 2014, 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states

0b0001 = 1 → 1

States
Raw valueStateMeaning
0NEUTRALNeutral
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear
11REARRear
13PARKPark

Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021. In testing for 2011 to 2012, 2014, 2017, 2020, 2022 to 2023. Not supported for 2006, 2026.

Torque converter lock status CHARGER_TQ_CONV_LOCK

  • Service 22DID B09B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Torque converter slip CHARGER_TQ_CONV_SLIP

  • Service 22DID B028
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission fluid temperature CHARGER_ATF_T_08DF

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 08DF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission fluid temperature CHARGER_ATF_T_7E1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 5043
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Example reply from a 2016 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x53 = 83 → 83−40 = 43 °C

Confirmed for 2016. In testing for 2006 to 2015, 2017 to 2023.

Transmission fluid temperature CHARGER_ATF_T_DA18Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 04FE
  • ModuleDA18 → 18
  • Every5 s
  • Testing for 2006 to 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2024 to 2025.

Transmission fluid temperature, variant 1 CHARGER_ATF_T_VAR_1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 72
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission fluid temperature, variant 3 CHARGER_ATF_T_2130

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission fluid temperature, variant 3 CHARGER_ATF_T_VAR_3

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID B010
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission sump temperature CHARGER_TRANS_SUMP_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 3A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission sump temperature, variant 1 CHARGER_TRANS_SUMP_T_VAR_1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission sump temperature, variant 2 CHARGER_TRANS_SUMP_T_VAR_2

  • Service 21PID CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2023. Supported for 2016.

Transmission temperature CHARGER_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 04FE
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2006 to 2012, 2014, 2017, 2020, 2022 to 2026

Example reply from a 2021 Dodge Charger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.8−40
Range
-30 to 300 °F
Unit
°F

0x42 = 66 → 66×1.8−40 = 78.8 °F

Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021. In testing for 2011 to 2012, 2014, 2017, 2020, 2022 to 2023. Not supported for 2006, 2026.

Transmission temperature, variant 2 CHARGER_TRANS_T_VAR_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 0A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2023. Not supported for 2016.

Transmission torque converter temperature, variant 1 CHARGER_TRANS_TQ_CONV_T_VAR_1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×9320+32
Range
0 to 1875 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Transmission torque converter temperature, variant 2 CHARGER_TRANS_TQ_CONV_T_VAR_2

  • Service 21PID CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2015, 2017 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
val×9320+32
Range
0 to 1875 °F
Unit
°F

In testing for 2006 to 2015, 2017 to 2023. Supported for 2016.

Transmission-reported torque CHARGER_TCM_TORQUEConfirmed

  • Service 22DID 1018
  • ModuleDA18 → 18
  • Every2 s
  • Testing for 2006 to 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val−500
Range
-500 to 1000 N·m
Unit
N·m

Confirmed for 2026. In testing for 2024 to 2025.

Trips

Odometer CHARGER_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 043B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2006 to 2012, 2014, 2017, 2020 to 2026

Example reply from a 2019 Dodge Charger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8.192
Range
0 to 536862.72 mi
Unit
mi

0x2C91 = 11409 → 11409×8.192 = 93,462.528 mi

Confirmed for 2013, 2015 to 2016, 2018 to 2019. In testing for 2011 to 2012, 2014, 2017, 2020 to 2023. Not supported for 2006, 2026.

Odometer CHARGER_ODO_03BC

Pelican can show this parameter as the odometer.

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2006 to 2015, 2017 to 2018. Not supported for 2016.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2021, 2023.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.