Dodge Hornet

Parameters

The Dodge Hornet has 60 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage HORNET_BATT_V_ECUConfirmed

  • Service 22DID 1955
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 20 V
Unit
V

Confirmed for 2024. In testing for 2023, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery voltage HORNET_BATT_V_ECUConfirmed

  • Service 22DID 1955
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 20 V
Unit
V

Confirmed for 2024. In testing for 2023, 2025.

Battery voltage, BCM HORNET_BATT_V_BCMConfirmed

  • Service 22DID 1004
  • ModuleDA40 → 40
  • Every30 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 V
Unit
V

Confirmed for 2024. In testing for 2023, 2025.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2023.

Details

Model year HORNET_MODEL_YEARConfirmed

  • Service 22DID F158
  • ModuleDA18 → 18
  • Every86400 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val+2000
Range
0 to 2225
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024. Supported for 2023.

Distance with water in fuel warning HORNET_WATER_FUEL_DISTConfirmed

  • Service 22DID 1009
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024. In testing for 2023, 2025.

Emissions

Catalyst inlet temperature HORNET_CATALYST_INLET_T

  • Service 22DID 3914
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 2023, 2025. Not supported for 2024.

Forced regen state HORNET_FORCED_REGENConfirmed

  • Service 22DID 18EC
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Lambda downstream DPF O2 concentration HORNET_LAMBDA_DPF_DSConfirmed

  • Service 22DID 18ED
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 25 %
Unit
%

Confirmed for 2024. In testing for 2023, 2025.

Particulate filter flow resistance HORNET_DPF_FLOW_RESConfirmed

  • Service 22DID 18E8
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Particulate filter regeneration interruptions, consecutive HORNET_REGEN_CONSEC_INTERRUPTEDConfirmed

  • Service 22DID 18AE
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Particulate filter regeneration interruptions, total HORNET_REGEN_INTERRUPTEDConfirmed

  • Service 22DID 18A5
  • ModuleDA10 → 10
  • Every60 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Particulate filter regeneration starts, total HORNET_REGEN_TOTALConfirmed

  • Service 22DID 18A4
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Engine

Automatic transmission fluid temperature HORNET_ATF_T_4THGEN

  • Service 22DID 04FE
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023, 2025. Not supported for 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2024. Supported for 2023.

Coolant temperature HORNET_ECT_ECUConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 1003
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

Confirmed for 2024. In testing for 2023, 2025.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2023.

Engine oil degradation HORNET_OIL_DEGRAD

  • Service 22DID 3813
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2023, 2025. Not supported for 2024.

Engine operational status HORNET_ENGINE_STATUSConfirmed

  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Engine RPM HORNET_RPM_DA10

  • Service 22DID 1000
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2023, 2025. Not supported for 2024.

Exhaust gas recirculation cooler outlet temperature HORNET_EGR_COOLER_T

  • Service 22DID 3917
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 2023, 2025. Not supported for 2024.

Fuel correction cylinder 1 HORNET_FUEL_CORR_CYL1

  • Service 22DID 3800
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2023, 2025. Not supported for 2024.

Fuel correction cylinder 2 HORNET_FUEL_CORR_CYL2

  • Service 22DID 3801
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2023, 2025. Not supported for 2024.

Fuel correction cylinder 3 HORNET_FUEL_CORR_CYL3

  • Service 22DID 3802
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2023, 2025. Not supported for 2024.

Fuel correction cylinder 4 HORNET_FUEL_CORR_CYL4

  • Service 22DID 3803
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2023, 2025. Not supported for 2024.

Fuel rail pressure commanded HORNET_RAIL_PRESS_CMD

  • Service 22DID 1946
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3000 bar
Unit
bar

In testing for 2023, 2025. Not supported for 2024.

Fuel rail pressure measured HORNET_RAIL_PRESS

  • Service 22DID 1947
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3000 bar
Unit
bar

In testing for 2023, 2025. Not supported for 2024.

IAT post-intercooler HORNET_IAT_TURBO

  • Service 22DID 1935
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

In testing for 2023, 2025. Not supported for 2024.

M-Prop injection command HORNET_MPROP_CMD

  • Service 22DID 18D0
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2023, 2025. Not supported for 2024.

Mass airflow sensor temperature HORNET_MAF_TEMP

  • Service 22DID 193F
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

In testing for 2023, 2025. Not supported for 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2024. Supported for 2023.

Swirl actuator command HORNET_SWIRL_CMDConfirmed

  • Service 22DID 189B
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-100 to 100 %
Unit
%

Confirmed for 2024. In testing for 2023, 2025.

Turbo boost pressure HORNET_BOOST

  • Service 22DID 195A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
-100 to 300 kPa
Unit
kPa

In testing for 2023, 2025. Not supported for 2024.

Turbocharger vane position actual HORNET_VGT_ACTConfirmed

  • Service 22DID 18A0
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2023, 2025.

Turbocharger vane position commanded HORNET_VGT_CMDConfirmed

  • Service 22DID 189F
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2023, 2025.

Variable oil pump position HORNET_OIL_PUMPConfirmed

  • Service 22DID 194F
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2024.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2024.

Fuel

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2024. Supported for 2023.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2023.

Movement

Front left wheel speed HORNET_WSS_FL

  • Service 22DID 2B1E
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 2023, 2025. Not supported for 2024.

Front right wheel speed HORNET_WSS_FR

  • Service 22DID 2B1D
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 2023, 2025. Not supported for 2024.

Rear left wheel speed HORNET_WSS_RL

  • Service 22DID 2B1C
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 2023, 2025. Not supported for 2024.

Rear right wheel speed HORNET_WSS_RR

  • Service 22DID 2B1B
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 2023, 2025. Not supported for 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024. Supported for 2023.

Vehicle speed, engine module HORNET_VSS_ECU

Pelican can show this parameter as the speed.

  • Service 22DID 190B
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 2023, 2025. Not supported for 2024.

Tires

Tire size HORNET_TIRE_SIZEConfirmed

  • Service 22DID 2024
  • ModuleDA18 → 18
  • Every86400 s
  • Testing for 2023, 2025

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

Confirmed for 2024. In testing for 2023, 2025.

Transmission

Automatic transmission temperature HORNET_ATF_T_3

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1D09
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2025.

Current gear HORNET_GEAR_CURRENTConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every500 ms
  • Testing for 2023, 2025

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Desired gear HORNET_GEAR_DESIREDConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every500 ms
  • Testing for 2023, 2025

Bits 0 to 3 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Gear HORNET_GEAR_3

  • Service 22DID 1D12
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2025.

Gear engaged HORNET_GEAR_ECUConfirmed

  • Service 22DID 192D
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2024. In testing for 2023, 2025.

Gearbox output speed HORNET_GEARBOX_RPM

  • Service 22DID 2102
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2023, 2025. Not supported for 2024.

Transmission input speed HORNET_AT_INPUT_RPM

  • Service 22DID 1D08
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2023 to 2025.

Transmission oil temperature HORNET_TOT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 18
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-512 to 512 °F
Unit
°F

In testing for 2023, 2025. Not supported for 2024.

Transmission output speed HORNET_AT_OUTPUT_RPM

  • Service 22DID 1D07
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2023 to 2025.

Transmission reported torque HORNET_TCM_TORQUE

  • Service 22DID 1018
  • ModuleDA18 → 18
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−500
Range
-500 to 2000 N·m
Unit
N·m

In testing for 2023, 2025. Not supported for 2024.

Trips

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.