Ford C-Max Energi

Parameters

The Ford C-Max Energi has 247 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage CMAXE_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7D = 125 → 12520+6 = 12.25 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age CMAXE_12V_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

0x0092 = 146 → 146×24 = 3,504 h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

12V battery state of charge CMAXE_12V_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x50 = 80 → 80 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

12V battery temperature CMAXE_12V_TConfirmed

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

0x34 = 52 → 52−40 = 12 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

12V battery voltage CMAXE_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7D = 125 → 12520+6 = 12.25 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Aux 12V battery control mode CMAXE_AUX_12V_BAT_CTRLConfirmed

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Average battery module voltage CMAXE_AVG_MODULE_VConfirmed

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x0CB8 = 3256 → 32561000 = 3.256 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Battery capacity too low for start/stop CMAXE_BAT_CAP_TOO_LOWConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery current too high for start/stop CMAXE_BAT_CURRENT_TOO_HIGHConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery discharge power limit CMAXE_BAT_DCHG_POWER_LIMConfirmed

  • Service 22DID 4852
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

0x23 = 35 → 35 kW

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery quiescent current, low range CMAXE_BAT_QUIESCENTConfirmed

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

0x0724 = 1828 → 18282−1000 = -86 mA

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery refresh cycle in progress for start/stop CMAXE_BAT_REFRESH_CYCLEConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery state of charge too low for start/stop CMAXE_BAT_ST_CHG_TOO_LOWConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery temperature too low for auto stop CMAXE_BAT_T_TOO_LOW_AUTOConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery voltage too low for auto restart CMAXE_BAT_V_TOO_LOW_AUTOConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery voltage too low for cold cranking capability CMAXE_BAT_V_TOO_LOW_COLDConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Battery voltage too low for start/stop CMAXE_BAT_V_TOO_LOW_STARTConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Charging state CMAXE_CHRG_STATEConfirmed

Pelican can show this parameter as the charging state.

  • Service 22DID 484F
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → NOT_READY

States
Raw valueStateMeaning
0NOT_READYNot ready
1READYReady
2FAULTFault
3WAITWait Check
4PRE_CONDPre-condition
5CHARGINGCharging
6DONEDone
7EXTExternal Charger
8INITInitializing

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Commanded generator voltage CMAXE_CMD_GEN_VConfirmed

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

0x7490 = 29840 → 29840×0.000488 = 14.56192 V

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Contactor voltage negative CMAXE_CONTACTOR_V_NEGATIVEConfirmed

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

0x0000 = 0 → 0100 = 0 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Contactor voltage positive CMAXE_CONTACTOR_V_POSITIVEConfirmed

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

0x0005 = 5 → 5100 = 0.05 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2014. Supported for 2016 to 2017.

DC-DC converter CMAXE_DCDC_ENABLEDConfirmed

  • Service 22DID 483D
  • Module746 → 74E
  • Every10 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage AC charger coupler temperature CMAXE_HIGH_V_AC_CHARGER_COUPLER_TConfirmed

  • Service 22DID D117
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

0x36 = 54 → 54×95−40 = 57.2 °F

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage battery current CMAXE_HVBAT_CURRENTConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

0x0000 = 0 → 050 = 0 A

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage charger current, requested CMAXE_HIGH_V_CHARGERConfirmed

  • Service 22DID 4842
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0000 = 0 → 0 A

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage charger input power available, raw count CMAXE_HIGH_V_CHARGER_INPUTConfirmed

  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage charger output current measured CMAXE_HIGH_V_CHARGER_OUTPUTConfirmed

  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

0x0000 = 0 → 0 A

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage charger output voltage, raw count CMAXE_HIGH_V_CHARGER_VConfirmed

  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0170 = 368 → 368

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage charger status CMAXE_HIGH_V_CHARGER_STATConfirmed

  • Service 22DID 484D
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage charger status CMAXE_HIGH_V_CHARGER_STAT_7E2Confirmed

  • Service 22DID 484F
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage charger voltage, requested CMAXE_HIGH_V_CHARGER_V_REQConfirmed

  • Service 22DID 4844
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 V
Unit
V

0x00 = 0 → 0×2 = 0 V

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage DC charger coupler temperature CMAXE_HIGH_V_DC_CHARGER_TConfirmed

  • Service 22DID D00C
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

0x39 = 57 → 57×95−40 = 62.6 °F

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High-voltage battery voltage, raw count CMAXE_HVB_V_RAW_CNTConfirmed

  • Service 22DID 480D
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x7148 = 29000 → 29,000

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

HV battery age CMAXE_HVBAT_AGEConfirmed

  • Service 22DID 4810
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×720200
Range
0 to 235926 h
Unit
h

0x306F = 12399 → 12399×720200 = 44,636.4 h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery charge CMAXE_HVBAT_SOCConfirmed

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 100 %
Unit
%

0x14A9 = 5289 → 5289500 = 10.578 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery charge, displayed CMAXE_HVBAT_SOC_DISPConfirmed

The state of charge displayed on the vehicle's dashboard.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4845
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery coolant inlet temperature CMAXE_BAT_CLT_INLET_TConfirmed

  • Service 22DID 4846
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x40 = 64 → 64−50 = 14 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery energy CMAXE_HVBAT_KWHConfirmed

  • Service 22DID 4848
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131.07 kWh
Unit
kWh

0x012C = 300 → 300500 = 0.6 kWh

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery temperature CMAXE_HVBAT_TConfirmed

  • Service 22DID 4800
  • Module7E4 → 7EC
  • Every10 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x40 = 64 → 64−50 = 14 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV battery voltage CMAXE_HVBAT_VConfirmed

  • Service 22DID 480D
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

0x6B00 = 27392 → 27392100 = 273.92 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV negative leakage voltage CMAXE_NEGATIVE_LEAKAGE_VConfirmed

  • Service 22DID 4804
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0000 = 0 → 01000 = 0 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

HV positive leakage voltage CMAXE_POSITIVE_LEAKAGE_VConfirmed

  • Service 22DID 4803
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0000 = 0 → 01000 = 0 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Hybrid battery pack remaining charge CMAXE_HYBRID_BAT_PACKConfirmed

  • Service 22DID F45B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x28 = 40 → 40×2051 = 15.686275 %

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Maximum discharge power limit CMAXE_CHG_POWER_LIMConfirmed

  • Service 22DID 4815
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25100
Range
0 to 63.75 kW
Unit
kW

0x00 = 0 → 0×25100 = 0 kW

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Minimum battery module voltage CMAXE_MIN_MODULE_VConfirmed

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x0C4B = 3147 → 31471000 = 3.147 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Normalized cumulative charge when ignition is on CMAXE_NORM_CUM_CHG_IGN_ONConfirmed

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x0424 = 1060 → 106010 = 106

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Normalized cumulative discharge from battery with engine off CMAXE_NORM_CUM_DCHG_BAT_OFFConfirmed

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x02BB = 699 → 69910 = 69.9

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Normalized cumulative discharge from battery with engine on CMAXE_NORM_CUM_DCHG_BAT_ONConfirmed

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x0014 = 20 → 2010 = 2

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

PF differential pressure feedback EGR sensor voltage CMAXE_PF_DIFF_P_FEEDBACK_VConfirmed

  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9771000000
Range
-32.01 to 32.01 V
Unit
V

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Primary motor inverter voltage CMAXE_PRIMARY_MOTOR_VConfirmed

  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

0x0A8A = 2698 → 269810 = 269.8 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

SOC variation battery modules CMAXE_SOC_VARIATION_BATConfirmed

  • Service 22DID 483E
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 %
Unit
%

0x00DF = 223 → 2231000 = 0.223 %

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Temperature range CMAXE_T_RANGEConfirmed

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x33 = 51 → 51−50 = 1 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Temperature range average CMAXE_T_RANGE_AVGConfirmed

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x40 = 64 → 64−50 = 14 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Temperature range, maximum CMAXE_T_RANGE_MAXConfirmed

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x41 = 65 → 65−50 = 15 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Temperature range, minimum CMAXE_T_RANGE_MINConfirmed

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x3F = 63 → 63−50 = 13 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Voltage variation battery modules CMAXE_V_VARIATION_BATConfirmed

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x0002 = 2 → 21000 = 0.002 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Climate

A/C compressor current CMAXE_AC_COMP_AConfirmed

  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10032767
Range
-100 to 100 A
Unit
A

0x0000 = 0 → 0×10032767 = 0 A

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

A/C compressor pressure CMAXE_AC_PConfirmed

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

0x00E0 = 224 → 224×245251845473 = 64.976911 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

A/C compressor pressure sensor voltage CMAXE_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

A/C compressor, state CMAXE_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Ambient temperature sensor voltage CMAXE_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Ambient temperature, alternate CMAXE_AAT_ALTConfirmed

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x5C = 92 → 922−40 = 6 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Exterior temperature CMAXE_AATConfirmed

  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2E = 46 → 46−40 = 6 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Interior temperature CMAXE_IATConfirmed

  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x33 = 51 → 51−40 = 11 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2014. Supported for 2016 to 2017.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2016 to 2017.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014.

Brake hydraulic pressure, raw count CMAXE_BRK_FL_PConfirmed

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Parking brake state CMAXE_PARKING_BRAKEConfirmed

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014. Supported for 2016 to 2017.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014.

Doors

Driver door ajar CMAXE_DRIVER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Hood ajar CMAXE_HOOD_OPENConfirmed

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Lock status CMAXE_CENTRAL_LOCK_STATUSConfirmed

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → UNLOCKED

States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Passenger door ajar CMAXE_PASSENGER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Rear left door ajar CMAXE_RLD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Rear right door ajar CMAXE_RRD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Trunk ajar CMAXE_TRUNK_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Drivetrain

Primary motor coil temperature CMAXE_PRI_MOTOR_COIL_TConfirmed

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

0x0010 = 16 → 16 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Primary motor inverter temperature CMAXE_PRI_MOTOR_INV_TConfirmed

  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

0x0013 = 19 → 19 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Primary motor speed CMAXE_PRI_MOTOR_RPMConfirmed

  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Primary motor torque CMAXE_PRI_MOTOR_TQConfirmed

  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2014, 2016 to 2017.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2014. Supported for 2016 to 2017.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2014. Supported for 2016 to 2017.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2014. Supported for 2016 to 2017.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014. Supported for 2016 to 2017.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014. Supported for 2016 to 2017.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2014. Supported for 2016 to 2017.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2014. Supported for 2016 to 2017.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2016 to 2017.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2016. Supported for 2014, 2017.

Accelerator position CMAXE_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014, 2016 to 2017.

Ambient air temperature CMAXE_AAT_7E0Confirmed

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x30 = 48 → 48−40 = 8 °C

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Barometric pressure CMAXE_BAROConfirmed

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

0x017A = 378 → 378×61516963 = 13.704533 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Battery current CMAXE_BAT_CURRENT_726Confirmed

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

0x1F98 = 8088 → 808816−511.7 = -6.2 A

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2016. Supported for 2017.

Camshaft position error, intake CMAXE_VCT_INT_ERRConfirmed

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Camshaft position, intake actual CMAXE_VCT_INT_ACTConfirmed

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Camshaft position, intake desired CMAXE_VCT_INT_DESConfirmed

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Camshaft solenoid duty cycle, intake CMAXE_VCT_INT_DUTYConfirmed

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Catalyst temperature CMAXE_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x022C = 556 → 55610−40 = 15.6 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Charging station connection, raw count CMAXE_EVSE_CHG_RAW_CNTConfirmed

  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2014, 2016 to 2017.

Coolant temperature CMAXE_ECTConfirmed

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Cylinder head temperature CMAXE_PCM_CYL_HEAD_T_CORRConfirmed

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x03EB = 1003 → 100364 = 15.671875 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Distance since DTC clear CMAXE_DIST_DTC_CLRConfirmed

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x000D = 13 → 13 km

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Distance with MIL CMAXE_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

DTC counter CMAXE_DTC_CNTConfirmed

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2016 to 2017.

Engine load CMAXE_ENG_LOAD_PCTConfirmed

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Engine load, actual CMAXE_ENG_LOAD_ACTConfirmed

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

0x0000 = 0 → 0×100255 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2016 to 2017. Supported for 2014.

Engine run time CMAXE_ERTConfirmed

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

0x00 = 0 → 0 s

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Engine run time CMAXE_RUN_TIMEConfirmed

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Engine speed CMAXE_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Evaporative pressure sensor, raw count CMAXE_EVAP_RAWConfirmed

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x02C6 = 710 → 710

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Evaporative purge CMAXE_EVAP_PURGE_CMDConfirmed

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10032768 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Exhaust gas recirculation CMAXE_EGRConfirmed

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Fuel pump duty cycle, low pressure CMAXE_LPFP_DUTYConfirmed

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x312A = 12586 → 12586×258192 = 38.409424 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Fuel trim, long term CMAXE_LTFTConfirmed

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x7E = 126 → 126×100128−100 = -1.5625 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Fuel trim, short term CMAXE_STFTConfirmed

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x5B = 91 → 91×100128−100 = -28.90625 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Generator coil temperature CMAXE_GEN_COIL_T_7E6Confirmed

  • Service 22DID 4820
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95
Range
-58982 to 58980 °C
Unit
°C

0x0011 = 17 → 17×95 = 30.6 °C

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Generator current CMAXE_GEN_CURRENTConfirmed

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

0x0000 = 0 → 0×78150000 = 0 A

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Glow plug, commanded status CMAXE_GLOW_PLUG_CMD_STATConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

0x00 = 0 → 0−4 = -4

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Grill shutter duty cycle CMAXE_GRILL_SHUT_DCConfirmed

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Grill shutter position CMAXE_GRILL_SHUTTER_POSConfirmed

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High voltage leakage resistance bus negative CMAXE_HIGH_V_LEAKAGE_RESConfirmed

  • Service 22DID 4812
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

High voltage leakage resistance bus positive CMAXE_HIGH_V_LEAKAGE_RES_BUSConfirmed

  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Ignition correction, cylinder 1 CMAXE_IGN_CORR_CYL1Confirmed

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Ignition timing, cylinder 1 CMAXE_IGN_TIM_CYL1Confirmed

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

0x0000 = 0 → 04 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

In car temperature CMAXE_CAR_TConfirmed

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

0x36 = 54 → 548 = 6.75 °C

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Intake temperature fault CMAXE_IAT_FAULTConfirmed

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Intake temperature sensor voltage CMAXE_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Intake temperature, alternate CMAXE_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x31 = 49 → 49−40 = 9 °C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Knock sensor, 1 CMAXE_KS1_RAWConfirmed

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Knock sensor, 2 CMAXE_KS2_RAWConfirmed

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Lambda correction CMAXE_CL_LCConfirmed

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Leakage resistance bus overall CMAXE_LEAKAGE_RES_BUSConfirmed

  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Low oil pressure switch CMAXE_LOW_OIL_P_SWITCHConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Low voltage converter current, high side CMAXE_LVB_DCDC_HV_CURRENTConfirmed

  • Service 22DID 483A
  • Module746 → 74E
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

0x00 = 0 → 010 = 0 A

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Low voltage converter current, low side CMAXE_LVB_DCDC_LV_CURRENTConfirmed

  • Service 22DID 4836
  • Module746 → 74E
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x00 = 0 → 0 A

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Manifold pressure CMAXE_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

0x15 = 21 → 21×1000068947 = 3.045818 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Manifold pressure sensor voltage CMAXE_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Mass airflow sensor frequency CMAXE_MASS_AIRFLOW_SENSConfirmed

  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 Hz
Unit
Hz

0x0AA3 = 2723 → 27234 = 680.75 Hz

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Misfire acceleration, cylinder 1 CMAXE_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Misfire acceleration, cylinder 2 CMAXE_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Misfire acceleration, cylinder 3 CMAXE_PCM_MISF_ACCEL_CYL3_NORMConfirmed

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Misfire acceleration, cylinder 4 CMAXE_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Misfire events, latest cycle CMAXE_PCM_MISF_EVENTS_LATEST_CYCConfirmed

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Navigation altitude CMAXE_SYNC_GPS_ALTITUDEConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0027 = 39 → 39

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Navigation heading CMAXE_SYNC_GPS_HEADINGConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

0x0165 = 357 → 357 °

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

O2 sensor voltage, rear CMAXE_RO2_VConfirmed

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

0x0000 = 0 → 01024 = 0 V

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Octane adjustment CMAXE_OARConfirmed

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Oil life remaining CMAXE_PCM_ENG_OIL_LIFE_REMConfirmed

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x1B = 27 → 27 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Outside temperature CMAXE_OUTSIDE_TConfirmed

  • Service 22DID DD05
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

0x33 = 51 → 51×95−40 = 51.8 °F

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2014, 2016. Supported for 2017.

Steering angle from the body module, actual value CMAXE_BCM_STEER_ANG_ACTConfirmed

  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−780
Range
-780 to 5773 °
Unit
°

0x12EE = 4846 → 484610−780 = -295.4 °

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Steering shaft torque CMAXE_STEER_SHFT_TQConfirmed

  • Service 22DID 330C
  • Module730 → 738
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

0x59 = 89 → 8910−12.7 = -3.8 N·m

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Temperature inside car CMAXE_T_INSIDE_CARConfirmed

  • Service 22DID DD04
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

0x36 = 54 → 54×95−40 = 57.2 °F

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Throttle angle, actual CMAXE_ETC_ANG_ACTConfirmed

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

0x0203 = 515 → 515512 = 1.005859 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Throttle angle, desired CMAXE_ETC_ANG_DESConfirmed

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

0x0233 = 563 → 563512 = 1.099609 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Throttle control trim angle, learned CMAXE_ETC_TRIM_LRNConfirmed

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Torque request CMAXE_TRQ_CTRL_REQConfirmed

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Transmission oil temperature CMAXE_TOTConfirmed

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

0x00F8 = 248 → 24816 = 15.5 °C

Confirmed for 2014, 2016. In testing for 2013, 2015, 2018. Not supported for 2017.

Warm-ups since DTC clear CMAXE_WARMUP_CLRConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Yaw rate signal CMAXE_YAW_RATE_SIGConfirmed

  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

0x0000 = 0 → 05 = 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2014, 2016 to 2017.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2014, 2016 to 2017.

Fuel

Air/fuel ratio CMAXE_AIR_FUEL_RATConfirmed

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

0x0000 = 0 → 0×0.000446787 = 0

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Fuel level CMAXE_FLI_7E0_7E0Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2016. Supported for 2017.

Lights

Exterior lighting state CMAXE_EXTERIOR_LIGHT_STATEConfirmed

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bit 0 of the reply.

Unit
Named states

0b0 = 0 → 0

States
Raw valueState
00
2161

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

High beam status CMAXE_HIGHBEAM_STATUSConfirmed

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Movement

Fan speed demanded CMAXE_FAN_SPD_DEMANDEDConfirmed

  • Service 22DID 0701
  • Module7E4 → 7EC
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

0x00 = 0 → 0×25 = 0 rpm

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Fan speed indicated CMAXE_FAN_SPD_INDICATEDConfirmed

  • Service 22DID 0702
  • Module7E4 → 7EC
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

0x00 = 0 → 0×25 = 0 rpm

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Fan speed, desired CMAXE_FAN_SPD_DESConfirmed

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

0x0A3D = 2621 → 2621×4013107 = 7.998779 %

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Front left wheel speed CMAXE_FL_VSSConfirmed

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Front right wheel speed CMAXE_FR_VSSConfirmed

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Lateral acceleration CMAXE_LAT_GConfirmed

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

0x0000 = 0 → 050 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Lateral angle, raw count CMAXE_LAT_ANGConfirmed

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0x0000 = 0 → 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Navigation speed CMAXE_SYNC_GPS_SPDConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

0x0000 = 0 → 0×185 = 0 km/h

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Rear left wheel speed CMAXE_RL_VSSConfirmed

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Rear right wheel speed CMAXE_RR_VSSConfirmed

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Vehicle speed CMAXE_VSSConfirmed

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2014. Supported for 2016 to 2017.

Vehicle speed, high resolution CMAXE_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2014. Supported for 2016 to 2017.

Tires

Front left tire pressure CMAXE_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x0186 = 390 → 39020 = 19.5 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Front right tire pressure CMAXE_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x02AD = 685 → 68520 = 34.25 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Rear left outer tire pressure CMAXE_TP_RLOConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x02C1 = 705 → 70520 = 35.25 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Rear right outer tire pressure CMAXE_TP_RROConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x02B2 = 690 → 69020 = 34.5 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Tire pressure, rear left inner CMAXE_TP_RLIConfirmed

  • Service 22DID 2818
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x010E = 270 → 27020 = 13.5 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Tire pressure, rear right inner CMAXE_TP_RRIConfirmed

  • Service 22DID 2817
  • Module726 → 72E
  • Every15 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

0x010E = 270 → 27020 = 13.5 psi

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Tire temperature CMAXE_TYRE_TConfirmed

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing for 2013, 2015, 2017 to 2018

Example reply from a 2016 Ford C-Max Energi.

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2014, 2016. In testing for 2013, 2015, 2017 to 2018.

Transmission

Axle gear ratio, measured CMAXE_AXLE_GEAR_RATIO_MEASConfirmed

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

0x0000 = 0 → 04096 = 0

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Current gear CMAXE_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → 1

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Gear commanded CMAXE_GEAR_CMDConfirmed

  • Service 22DID 1E12
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNKNOWNUnknown
20L
40D
50N
60R
70P
255FAULTFault

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Gear ratio, commanded CMAXE_PCM_CMD_TRANS_GEAR_RATIOConfirmed

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Gear, shift CMAXE_GEAR_SHFTConfirmed

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x3C = 60 → REVERSE

States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Transmission temperature CMAXE_TTConfirmed

  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2013, 2015, 2018

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-300 to 300 °C
Unit
°C

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Trips

Odometer CMAXE_ODO_7E0Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x01D9FF = 121343 → 121,343 km

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Odometer, brake module CMAXE_ABS_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x01D9FE = 121342 → 121,342 km

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Odometer, instrument panel CMAXE_ODO_726Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing for 2013, 2015, 2018

Example reply from a 2017 Ford C-Max Energi.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x01D9FE = 121342 → 121,342 km

Confirmed for 2014, 2016 to 2017. In testing for 2013, 2015, 2018.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.