Ford C-Max

Parameters

The Ford C-Max has 307 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage CMAX_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7D = 125 → 12520+6 = 12.25 V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery voltage CMAX_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7D = 125 → 12520+6 = 12.25 V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Aux 12V battery control mode CMAX_AUX_12V_BAT_CTRL

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2019.

Battery age CMAX_BATT_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1825
Unit
Number

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Battery capacity too low for start/stop CMAX_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery charge CMAX_BATT_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every10 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x39 = 57 → 57 %

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Battery current too high for start/stop CMAX_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery current, predicted CMAX_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

In testing for 2003 to 2019.

Battery percentage, state of charge CMAX_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2019.

Battery quiescent current, low range CMAX_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 2003 to 2019.

Battery refresh cycle in progress for start/stop CMAX_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery state detection status CMAX_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2019.

Battery state of charge too low for start/stop CMAX_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery temperature CMAX_BATT_TEMPConfirmed

  • Service 22DID 4029
  • Module726 → 72E
  • Every10 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

0x51 = 81 → 81−40 = 41 °C

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Battery temperature too low for auto stop CMAX_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery voltage CMAX_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2003 to 2019.

Battery voltage CMAX_BAT_V_7E0

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2003 to 2019.

Battery voltage too low for auto restart CMAX_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery voltage too low for cold cranking capability CMAX_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Battery voltage too low for start/stop CMAX_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Charge air temperature CMAX_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Commanded generator voltage CMAX_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

In testing for 2003 to 2019.

Injection control pressure sensor voltage CMAX_ICP_V

  • Service 22DID 16AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2003 to 2019.

Normalized cumulative charge when ignition is on CMAX_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2019.

Normalized cumulative discharge from battery with engine off CMAX_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2019.

Normalized cumulative discharge from battery with engine on CMAX_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2019.

PF differential pressure feedback EGR sensor voltage CMAX_PF_DIFF_P_FEEDBACK_V

  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9771000000
Range
-32.01 to 32.01 V
Unit
V

In testing for 2003 to 2019.

Vehicle battery b current CMAX_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 2003 to 2019.

Vehicle battery b voltage CMAX_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2003 to 2019.

Vehicle battery current CMAX_VEH_BAT_CURRENT

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Climate

A/C compressor pressure CMAX_AC_PConfirmed

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

0x05AA = 1450 → 1450×245251845473 = 420.60947 psi

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

A/C compressor pressure sensor voltage CMAX_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

A/C compressor, state CMAX_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

A/C refrigerant pressure CMAX_PCM_A_C_REFRIG_P

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Ambient temperature sensor voltage CMAX_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Ambient temperature, alternate CMAX_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2013. Supported for 2008, 2012, 2015.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013. Supported for 2006, 2012, 2015.

Anti-lock brake lateral acceleration CMAX_ABS_LATERAL_ACCEL

  • Service 22DID 3A51
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g
Unit
g

In testing for 2003 to 2019.

Anti-lock brake wheel speed 1 CMAX_ABS_WHL_SPD_1

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019.

Anti-lock brake wheel speed 2 CMAX_ABS_WHL_SPD_2

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019.

Anti-lock brake wheel speed 3 CMAX_ABS_WHL_SPD_3

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019.

Anti-lock brake wheel speed 4 CMAX_ABS_WHL_SPD_4

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019.

Brake booster pressure CMAX_BRAKE_BOOSTER_P

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 kPa
Unit
kPa

In testing for 2003 to 2019.

Brake hydraulic pressure CMAX_BRK_FL_PConfirmed

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x00 = 0 → 0 kPa

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Foot brake CMAX_FOOT_BRAKE

  • Service 22DID 3B40
  • Module703 → 70B
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Parking brake CMAX_PARK_BRKConfirmed

  • Service 22DID 2B00
  • Module760 → 768
  • Every2 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Steering wheel angle CMAX_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×6.25
Range
-790 to 790 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Doors

Driver door ajar CMAX_DRIVER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Hood ajar? CMAX_HOOD_OPENConfirmed

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Lock status CMAX_CENTRAL_LOCK_STATUSConfirmed

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → UNLOCKED

States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Passenger door ajar? CMAX_PASSENGER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Rear left door ajar? CMAX_RLD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Rear right door ajar? CMAX_RRD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Trunk ajar? CMAX_TRUNK_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Engine

Accelerator position CMAX_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Actual engine percent torque CMAX_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Actuator cam position corrected CMAX_ACTUATOR_CAM_POS

  • Service 22DID 017C
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °
Unit
°

In testing for 2003 to 2019.

Actuator duty cycle output, commanded CMAX_ACTUATOR_DUTY_OUTPUT_CMD

  • Service 22DID 017F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1953500000
Range
-127 to 127 %
Unit
%

In testing for 2003 to 2019.

Air conditioning pressure CMAX_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

In testing for 2003 to 2019.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2013. Supported for 2006, 2008, 2012.

Alternator 2 monitor CMAX_ALTERNATOR_2_MON

  • Service 22DID 0455
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Alternator current output CMAX_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

In testing for 2003 to 2019.

Ambient air temperature CMAX_AAT_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Barometric pressure CMAX_BARO

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Barometric pressure CMAX_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2003 to 2019.

Barometric pressure sensor voltage CMAX_BARO_V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Battery current CMAX_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2003 to 2019.

Boost CMAX_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2003 to 2019.

Bypass valve CMAX_BPV_OPEN

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position error, exhaust CMAX_VCT_EXH_ERR

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position error, intake CMAX_VCT_INT_ERR

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position, exhaust actual CMAX_VCT_EXH_ACT

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position, exhaust desired CMAX_VCT_EXH_DES

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position, intake actual CMAX_VCT_INT_ACT

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft position, intake desired CMAX_VCT_INT_DES

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft solenoid duty cycle, exhaust CMAX_VCT_EXH_DUTY

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Camshaft solenoid duty cycle, intake CMAX_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Catalyst temperature CMAX_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x0578 = 1400 → 140010−40 = 100 °C

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Charge air temperature CMAX_CAT

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Charge air temperature sensor voltage CMAX_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Commanded generator duty CMAX_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Coolant temperature CMAX_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Cylinder 1 misfire count CMAX_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 2 misfire count CMAX_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 3 misfire count CMAX_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 4 misfire count CMAX_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 5 misfire count CMAX_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 6 misfire count CMAX_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 7 misfire count CMAX_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder 8 misfire count CMAX_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Cylinder head temperature CMAX_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Cylinder head temperature CMAX_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2019.

Cylinder head temperature CMAX_CYL_HEAD_T_7E0_2

  • Service 22DID F405
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Cylinder head temperature CMAX_PCM_CYL_HEAD_T_CORR

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Cylinder head temperature, alternate CMAX_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2003 to 2019.

Cylinder head temperature, sensor 2 CMAX_PCM_CYL_HEAD_T_SENS_2_RAW

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Distance since DTC clear CMAX_DIST_DTC_CLRConfirmed

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Distance with MIL CMAX_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

DTC counter CMAX_DTC_CNT

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2019.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013. Supported for 2006, 2008, 2012, 2015.

Engine load CMAX_ENG_LOAD_PCTConfirmed

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Engine load, actual CMAX_ENG_LOAD_ACT

Pelican can show this parameter as the engine load.

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Engine oil pressure - desired CMAX_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2003 to 2019.

Engine oil temperature CMAX_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2003 to 2019.

Engine oil temperature, alternate CMAX_EOT_F45C

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Engine oil temperature, variant 2 CMAX_EOT_VAR_2

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Engine reference torque CMAX_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Engine run time CMAX_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Engine run time CMAX_RUN_TIMEConfirmed

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Engine speed CMAX_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Evaporative pressure sensor voltage CMAX_EVAP_V

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Evaporative purge CMAX_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Exhaust back pressure CMAX_EXH_BACK_P

  • Service 22DID 1445
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29800
Range
0 to 2375 psi
Unit
psi

In testing for 2003 to 2019.

Exhaust gas recirculation CMAX_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas recirculation cooler inlet temperature CMAX_EGR_COOLER_INLET_T

  • Service 22DID 0569
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas recirculation cooler outlet temperature CMAX_EGR_COOLER_OUTLET_T

  • Service 22DID 055D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas recirculation duty cycle CMAX_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas recirculation inlet temperature CMAX_EGR_INLET_T

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2019.

Exhaust gas recirculation open CMAX_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas recirculation temperature CMAX_EGR_T_7E0

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas recirculation temperature CMAX_EGR_T_7E0_7E0

  • Service 22DID F46B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas recirculation temperature a CMAX_EGR_T

  • Service 22DID 115F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2019.

Exhaust gas recirculation throttle position signal CMAX_EGR_THROTTLE_POS_SIG

  • Service 22DID 096C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas recirculation valve position measured CMAX_EGR_VLV_POS_MEAS

  • Service 22DID 09FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas recirculation valve position, desired CMAX_EGR_VLV_POS_DES

  • Service 22DID 09D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Exhaust gas temperature 1 CMAX_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas temperature 2 CMAX_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas temperature after turbo, before oxidation catalyst CMAX_EGT_PRE_DOC

  • Service 22DID 0991
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2003 to 2019.

Exhaust gas temperature, bank 1 CMAX_EGT_B1

  • Service 22DID F478
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2003 to 2019.

Fuel pressure sensor voltage, low CMAX_LPFP_SENS_V

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Fuel pressure, high desired CMAX_HPFP_DESConfirmed

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0BB8 = 3000 → 3000×10 = 30,000 kPa

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Fuel pressure, low actual CMAX_LPFP_ACT

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Fuel pressure, low desired CMAX_LPFP_DES

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Fuel pump duty cycle, low pressure CMAX_LPFP_DUTY

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Fuel pump pulse width, bank 2 CMAX_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2003 to 2019.

Fuel rail sensor voltage, high pressure CMAX_HPFP_VConfirmed

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Fuel trim, long term CMAX_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Fuel trim, short term CMAX_STFT

Pelican can show this parameter as the short term fuel trim.

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Generator coil temperature CMAX_GEN_COIL_T

  • Service 22DID 4972
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×180+320
Range
0 to 11796620 °F
Unit
°F

In testing for 2003 to 2019.

Generator control CMAX_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Generator current CMAX_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

In testing for 2003 to 2019.

Glow plug, commanded status CMAX_GLOW_PLUG_CMD_STAT

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

In testing for 2003 to 2019.

Grill shutter duty cycle CMAX_GRILL_SHUT_DCConfirmed

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Grill shutter position CMAX_GRILL_SHUTTER_POS

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Hydraulic pump motor current CMAX_HYDRAULIC_PMP_MOTOR

  • Service 22DID D00F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2003 to 2019.

Ignition correction, cylinder 1 CMAX_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Ignition timing, cylinder 1 CMAX_IGN_TIM_CYL1

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

In car temperature CMAX_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2003 to 2019.

Injection control pressure CMAX_INJ_CTRL_P

  • Service 22DID 1446
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×57100
Range
0 to 37354 psi
Unit
psi

In testing for 2003 to 2019.

Injection mode CMAX_INJ_MODE

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Injection pressure regulator duty cycle CMAX_IPR_DUTY

  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2003 to 2019.

Injector control module cam and crank sync CMAX_FICM_SYNC

  • Service 22DID 09CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2003 to 2019.

Injector control module logic power CMAX_FICM_LOGIC_POWER

  • Service 22DID 09CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

In testing for 2003 to 2019.

Injector control module main power CMAX_FICM_MAIN_POWER

  • Service 22DID 09D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

In testing for 2003 to 2019.

Injector impulse width CMAX_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2003 to 2019.

Intake air temperature 1 CMAX_IAT_1

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2019.

Intake air temperature 2 CMAX_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2003 to 2019.

Intake temperature fault CMAX_IAT_FAULTConfirmed

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Intake temperature sensor voltage CMAX_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Intake temperature, alternate CMAX_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x72 = 114 → 114−40 = 74 °C

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Knock counter, cylinder 1 CMAX_PCM_CYL_1_KNK_COMB_PERF_CNT

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock counter, cylinder 2 CMAX_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock counter, cylinder 3 CMAX_PCM_CYL_3_KNK_COMB_PERF_CNT

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock counter, cylinder 4 CMAX_PCM_CYL_4_KNK_COMB_PERF_CNT

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock counter, cylinder 5 CMAX_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock counter, cylinder 6 CMAX_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock sensor, 1 CMAX_KS1_RAW

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Knock sensor, 2 CMAX_KS2_RAW

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Lambda correction CMAX_CL_LC

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Lambda, commanded CMAX_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Low oil pressure switch CMAX_LOW_OIL_P_SWITCH

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Manifold absolute pressure, high resolution CMAX_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

In testing for 2003 to 2019.

Manifold air temperature CMAX_MANIFOLD_AIR_T

  • Service 22DID 16E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2003 to 2019.

Manifold pressure CMAX_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

0x09 = 9 → 9×1000068947 = 1.30535 psi

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Manifold pressure sensor voltage CMAX_MAP_V

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Manifold temperature CMAX_MCT

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Mass airflow sensor frequency CMAX_MASS_AIRFLOW_SENS

  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 Hz
Unit
Hz

In testing for 2003 to 2019.

Misfire acceleration, cylinder 1 CMAX_PCM_MISF_ACCEL_CYL1_NORM

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 2 CMAX_PCM_MISF_ACCEL_CYL2_NORM

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 3 CMAX_PCM_MISF_ACCEL_CYL3_NORM

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 4 CMAX_PCM_MISF_ACCEL_CYL4_NORM

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 5 CMAX_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 6 CMAX_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire events, latest cycle CMAX_PCM_MISF_EVENTS_LATEST_CYC

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Misfire monitor status CMAX_MIS_MON_STAT

  • Service 22DID 03C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2019.

Navigation altitude CMAX_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Navigation heading CMAX_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2003 to 2019.

O2 sensor voltage, rear CMAX_RO2_V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Octane adjustment CMAX_OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Oil life remaining CMAX_PCM_ENG_OIL_LIFE_REM

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Oil pressure CMAX_PCM_ENG_EOP_RAW

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Power transfer unit sump temperature CMAX_POWER_TRANSFER_UNIT_T

  • Service 22DID 0184
  • Module703 → 70B
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °C
Unit
°C

In testing for 2003 to 2019.

Power transfer unit, requested torque CMAX_POWER_TRANSFER_UNIT_REQ_TQ

  • Service 22DID 0182
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2019.

Power transfer unit, requested torque capacity inferred CMAX_POWER_TRANSFER_UNIT_REQ_TQ_CAP

  • Service 22DID 0185
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2019.

Steering angle from the body module, actual value CMAX_BCM_STEER_ANG_ACT

  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−780
Range
-780 to 5773 °
Unit
°

In testing for 2003 to 2019.

Steering shaft torque CMAX_STEER_SHFT_TQ

  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

In testing for 2003 to 2019.

Sump oil temperature measured CMAX_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Throttle angle, actual CMAX_ETC_ANG_ACT

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Throttle angle, desired CMAX_ETC_ANG_DES

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Throttle control trim angle, learned CMAX_ETC_TRIM_LRN

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Throttle inlet pressure CMAX_TIP_ABS

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Throttle inlet pressure sensor voltage CMAX_TIP_VConfirmed

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2012, 2014 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Throttle inlet pressure, desired CMAX_TIP_DES_ABS

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Time since last oil change CMAX_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2003 to 2019.

Torque converter slip CMAX_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2003 to 2019.

Torque into torque converter CMAX_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2003 to 2019.

Torque into torque converter CMAX_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2019.

Torque request CMAX_TRQ_CTRL_REQ

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Total misfire count CMAX_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019.

Transfer case fluid temperature CMAX_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2003 to 2019.

Transmission fluid temperature, variant 1 CMAX_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2003 to 2019.

Transmission fluid temperature, variant 2 CMAX_ATF_T_VAR_2

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2019.

Transmission fluid temperature, variant 5 CMAX_ATF_T_VAR_5

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2003 to 2019.

Transmission fluid temperature, variant 6 CMAX_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2019.

Transmission oil temperature CMAX_TOT_7E0

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Turbo boost CMAX_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2003 to 2019.

Turbo inlet pressure CMAX_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2003 to 2019.

Variable geometry turbo duty cycle CMAX_VGT_DUTY

  • Service 22DID 096D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Warm-ups since DTC clear CMAX_WARMUP_CLRConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Wastegate control CMAX_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Wastegate duty cycle CMAX_WGDC

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Yaw rate signal CMAX_YAW_RATE_SIG

  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

In testing for 2003 to 2019.

Fuel

Air/fuel ratio CMAX_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

In testing for 2003 to 2019.

Cylinder 1 fuel balance correction CMAX_CYL_1_FUEL_BALANCE

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 1 fuel quantity CMAX_CYL_1_FUEL_QTY

  • Service 22DID 04AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 2 fuel balance correction CMAX_CYL_2_FUEL_BALANCE

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 2 fuel quantity CMAX_CYL_2_FUEL_QTY

  • Service 22DID 04AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 3 fuel balance correction CMAX_CYL_3_FUEL_BALANCE

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 3 fuel quantity CMAX_CYL_3_FUEL_QTY

  • Service 22DID 04AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 4 fuel balance correction CMAX_CYL_4_FUEL_BALANCE

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 4 fuel quantity CMAX_CYL_4_FUEL_QTY

  • Service 22DID 04AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 5 fuel balance correction CMAX_CYL_5_FUEL_BALANCE

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 5 fuel quantity CMAX_CYL_5_FUEL_QTY

  • Service 22DID 04AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 6 fuel balance correction CMAX_CYL_6_FUEL_BALANCE

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 6 fuel quantity CMAX_CYL_6_FUEL_QTY

  • Service 22DID 04AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 7 fuel balance correction CMAX_CYL_7_FUEL_BALANCE

  • Service 22DID 04A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 7 fuel quantity CMAX_CYL_7_FUEL_QTY

  • Service 22DID 04B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 8 fuel balance correction CMAX_CYL_8_FUEL_BALANCE

  • Service 22DID 04A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Cylinder 8 fuel quantity CMAX_CYL_8_FUEL_QTY

  • Service 22DID 04B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2019.

Dilution of oil with fuel CMAX_DILUTION_OIL_FUEL

  • Service 22DID 054C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2019.

Engine fuel rate CMAX_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

In testing for 2003 to 2019.

Fuel injection impulse width CMAX_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2003 to 2019.

Fuel level CMAX_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x30 = 48 → 48×100255 = 18.823529 %

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Fuel level CMAX_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2003 to 2019.

Fuel pump duty cycle CMAX_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2003 to 2019.

Fuel rail pressure control CMAX_FUEL_RAIL_P_CTRL

  • Service 22DID 03C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2003 to 2019.

Fuel tank pressure CMAX_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2003 to 2019.

Fuel temperature CMAX_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Fuel temperature a CMAX_FUEL_T_7E0

  • Service 22DID 0429
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2003 to 2019.

Low side fuel rail pressure CMAX_LOW_SIDE_FUEL_RAIL_P

  • Service 22DID 064E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 kPa
Unit
kPa

In testing for 2003 to 2019.

Mass fuel, desired CMAX_MASS_FUEL_DES

  • Service 22DID 1412
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2003 to 2019.

Volume fuel, desired CMAX_VOLUME_FUEL_DES

  • Service 22DID 1411
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2003 to 2019.

Lights

Exterior lighting state CMAX_EXTERIOR_LIGHT_STATEConfirmed

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bit 0 of the reply.

Unit
Named states

0b0 = 0 → 0

States
Raw valueState
00
2161

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

High beam status CMAX_HIGHBEAM_STATUSConfirmed

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

0x0000 = 0 → 0

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Movement

Accelerator pedal position CMAX_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2003 to 2019.

Actual output shaft speed CMAX_ACT_OUTPUT_SHFT_SPD

  • Service 22DID 1E1B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2003 to 2019.

Actual turbine shaft speed CMAX_ACT_TURBINE_SHFT_SPD

  • Service 22DID 1E13
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2003 to 2019.

Fan speed sensor CMAX_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2003 to 2019.

Fan speed, desired CMAX_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Front left wheel speed CMAX_FL_VSSConfirmed

  • Service 22DID 2B07
  • Module760 → 768
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Front right wheel speed CMAX_FR_VSSConfirmed

  • Service 22DID 2B06
  • Module760 → 768
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Lateral acceleration CMAX_LAT_GConfirmed

  • Service 22DID 2B11
  • Module760 → 768
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

0x0006 = 6 → 650 = 0.12

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Lateral angle CMAX_LAT_ANGConfirmed

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0xFFFC = -4 → -4

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Navigation speed CMAX_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

In testing for 2003 to 2019.

Power transfer unit input shaft speed CMAX_POWER_TRANSFER_UNIT

  • Service 22DID 017E
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2003 to 2019.

Rear left wheel speed CMAX_RL_VSSConfirmed

  • Service 22DID 2B09
  • Module760 → 768
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Rear right wheel speed CMAX_RR_VSSConfirmed

  • Service 22DID 2B08
  • Module760 → 768
  • Every100 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Vehicle speed CMAX_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Vehicle speed, high resolution CMAX_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Tires

4 wheel drive engaged CMAX_4_WHL_DRIVE_ENGAGED

  • Service 22DID A211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2003 to 2019.

Front left tire pressure CMAX_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Front right tire pressure CMAX_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Rear left inner tire pressure CMAX_TP_RLI

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Rear left outer tire pressure CMAX_TP_RLO

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Rear right inner tire pressure CMAX_TP_RRI

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Rear right outer tire pressure CMAX_TP_RRO

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 149.95 psi
Unit
psi

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Tire temperature CMAX_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2019.

Transmission

Actual torque converter slip CMAX_ACT_TQ_CONV_SLIP

  • Service 22DID 1E14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2003 to 2019.

All-wheel drive clutch diagnostic signal CMAX_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

All-wheel drive clutch, commanded control signal CMAX_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2019.

Axle gear ratio, measured CMAX_AXLE_GEAR_RATIO_MEAS

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Converter speed ratio CMAX_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2003 to 2019.

Current gear CMAX_GEAR

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Desired torque converter slip CMAX_DES_TQ_CONV_SLIP

  • Service 22DID 1E35
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2003 to 2019.

Gear CMAX_GEAR_7E1

  • Service 22DID 1E1F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047
Unit
Number

In testing for 2003 to 2019.

Gear ratio, commanded CMAX_PCM_CMD_TRANS_GEAR_RATIO

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Gear, engaged CMAX_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Measured current of clutch a actuator CMAX_MEAS_CURRENT_CLU

  • Service 22DID 1E9E
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 A
Unit
A

In testing for 2003 to 2019.

Shift gear CMAX_GEAR_SHFT

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Torque converter line pressure CMAX_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2003 to 2019.

Torque into torque converter, variant 2 CMAX_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2019.

Transmission fluid fluid quality CMAX_TRANS_FLUID_FLUID

  • Service 22DID 180F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2019.

Transmission gear CMAX_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2019.

Transmission gear CMAX_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2019.

Transmission gear ratio CMAX_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2003 to 2019.

Transmission odometer CMAX_TRANS_ODO

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 °C
Unit
°C

In testing for 2003 to 2019.

Transmission output shaft speed CMAX_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2003 to 2019.

Transmission pressure, commanded CMAX_PCM_CMD_TRANS_MAIN_LINE_P

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Trips

Distance since last complete regeneration CMAX_DIST_SINCE_COMPLETE

  • Service 22DID 0434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×625
Range
0 to 4026531 mi
Unit
mi

In testing for 2003 to 2019.

Distance since last oil change CMAX_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2019.

Distance to empty, calculated CMAX_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Distance to empty, displayed CMAX_DTE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.

Odometer CMAX_ODO_7E0Confirmed

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x032666 = 206438 → 206,438 km

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Odometer, brake module CMAX_ABS_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x032666 = 206438 → 206,438 km

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Odometer, instrument panel CMAX_ODO_726Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2019

Example reply from a 2013 Ford C-Max.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x032666 = 206438 → 206,438 km

Confirmed for 2013. In testing for 2003 to 2012, 2014 to 2019.

Total distance, lifetime CMAX_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2003 to 2019.

Vehicle odometer CMAX_PCM_VEH_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2003 to 2012, 2014 to 2019. Not supported for 2013.