Ford Everest

Parameters

The Ford Everest has 416 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage EVEREST_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7A = 122 → 12220+6 = 12.1 V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age EVEREST_12V_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

0x0000 = 0 → 0×24 = 0 h

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

12V battery current EVEREST_VEH_BAT_CURRENTConfirmed

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

0x48 = 72 → 72−127 = -55 A

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

12V battery state of charge EVEREST_12V_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x41 = 65 → 65 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

12V battery temperature EVEREST_12V_T

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

12V battery voltage EVEREST_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7A = 122 → 12220+6 = 12.1 V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Aux 12V battery control mode EVEREST_AUX_12V_BAT_CTRL

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2026.

Battery capacity too low for start/stop EVEREST_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery current too high for start/stop EVEREST_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery current, predicted EVEREST_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

In testing for 2003 to 2024, 2026. Not supported for 2025.

Battery percentage, state of charge EVEREST_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2026.

Battery quiescent current, low range EVEREST_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 2003 to 2026.

Battery refresh cycle in progress for start/stop EVEREST_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery state detection status EVEREST_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Battery state of charge too low for start/stop EVEREST_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery temperature too low for auto stop EVEREST_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery voltage EVEREST_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2003 to 2026.

Battery voltage too low for auto restart EVEREST_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery voltage too low for cold cranking capability EVEREST_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Battery voltage too low for start/stop EVEREST_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Charge air cooler temperature EVEREST_CHG_AIR_COOLER_T

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280
Unit
Raw value

In testing for 2003 to 2026.

Charge air temperature EVEREST_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Commanded generator voltage EVEREST_CMD_GEN_VConfirmed

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

0x72A9 = 29353 → 29353×0.000488 = 14.324264 V

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2024. Supported for 2025.

Normalized cumulative charge when ignition is on EVEREST_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Normalized cumulative discharge from battery with engine off EVEREST_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2026.

Normalized cumulative discharge from battery with engine on EVEREST_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2003 to 2026.

PF differential pressure feedback EGR sensor voltage EVEREST_PF_DIFF_P_FEEDBACK_VConfirmed

  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9771000000
Range
-32.01 to 32.01 V
Unit
V

0x0604 = 1540 → 1540×9771000000 = 1.50458 V

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Second battery current EVEREST_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 2003 to 2026.

Second battery voltage EVEREST_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2003 to 2026.

Climate

A/C compressor pressure EVEREST_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor pressure sensor voltage EVEREST_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

A/C compressor, state EVEREST_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

A/C refrigerant pressure EVEREST_PCM_A_C_REFRIG_PConfirmed

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

0x02BA = 698 → 698 kPa

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Ambient temperature sensor voltage EVEREST_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ambient temperature, alternate EVEREST_AAT_ALTConfirmed

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x94 = 148 → 1482−40 = 34 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2024. Supported for 2025.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Anti-lock brake lateral acceleration EVEREST_ABS_LATERAL_ACCEL

  • Service 22DID 3A51
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g
Unit
g

In testing for 2003 to 2026.

Anti-lock brake wheel speed 1 EVEREST_ABS_WHL_SPD_1

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2026.

Anti-lock brake wheel speed 2 EVEREST_ABS_WHL_SPD_2

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2026.

Anti-lock brake wheel speed 3 EVEREST_ABS_WHL_SPD_3

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2026.

Anti-lock brake wheel speed 4 EVEREST_ABS_WHL_SPD_4

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2026.

Brake booster pressure EVEREST_BRAKE_BOOSTER_P

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 kPa
Unit
kPa

In testing for 2003 to 2026.

Brake hydraulic pressure, raw count EVEREST_BRK_FL_PConfirmed

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Parking brake state EVEREST_PARKING_BRAKEConfirmed

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2024 Ford Everest.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2026. Supported for 2025.

Steering wheel angle EVEREST_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1638.4
Range
-1638 to 1638 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Cruise control

Target speed EVEREST_CC_TGT_VSSConfirmed

The speed of the vehicle ahead of you.

  • Service 22DID A224
  • Module764 → 76C
  • Every500 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×3.610
Range
-736 to 736 km/h
Unit
km/h

0x0000 = 0 → 0×3.610 = 0 km/h

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Doors

Driver door ajar EVEREST_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Hood ajar? EVEREST_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lock status EVEREST_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Passenger door ajar? EVEREST_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left door ajar? EVEREST_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right door ajar? EVEREST_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Trunk ajar? EVEREST_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024 to 2025.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024. Supported for 2025.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2024.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2024. Supported for 2025.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2024. Supported for 2025.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. Supported for 2025.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2024.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. Supported for 2025.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2024. Supported for 2025.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2024. Supported for 2025.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2025.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2025.

Accelerator position EVEREST_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual engine percent torque EVEREST_PCM_ACT_ENG_PCT_TRQConfirmed

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

0x84 = 132 → 132−125 = 7 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Air conditioning pressure EVEREST_AC_P_7E0Confirmed

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

0x00 = 0 → 0×12.156863 = 0 kPa

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024.

Alternator 2 monitor EVEREST_ALTERNATOR_2_MON

  • Service 22DID 0455
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Alternator current output EVEREST_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

In testing for 2003 to 2024, 2026. Not supported for 2025.

Ambient air temperature EVEREST_AAT_7E0Confirmed

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x52 = 82 → 82−40 = 42 °C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Barometric pressure EVEREST_BAROConfirmed

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

0x0178 = 376 → 376×61516963 = 13.632023 psi

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Barometric pressure EVEREST_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2003 to 2026.

Barometric pressure sensor voltage EVEREST_BARO_VConfirmed

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Battery current EVEREST_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2003 to 2026.

Boost EVEREST_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2003 to 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Bypass valve EVEREST_BPV_OPENConfirmed

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

0x00 = 0 → 0255 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2025.

Camshaft position error, exhaust EVEREST_VCT_EXH_ERRConfirmed

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0005 = 5 → 516 = 0.3125 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position error, intake EVEREST_VCT_INT_ERRConfirmed

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, exhaust actual EVEREST_VCT_EXH_ACTConfirmed

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, exhaust desired EVEREST_VCT_EXH_DESConfirmed

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, intake actual EVEREST_VCT_INT_ACTConfirmed

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, intake desired EVEREST_VCT_INT_DESConfirmed

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft solenoid duty cycle, exhaust EVEREST_VCT_EXH_DUTYConfirmed

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft solenoid duty cycle, intake EVEREST_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature EVEREST_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x1532 = 5426 → 542610−40 = 502.6 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Charge air temperature EVEREST_CATConfirmed

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

0x0000 = 0 → 064−40 = -40 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Charge air temperature sensor voltage EVEREST_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded generator duty EVEREST_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Coolant temperature EVEREST_ECTConfirmed

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x16A3 = 5795 → 579564 = 90.546875 °C

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Cylinder 1 misfire count EVEREST_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 2 misfire count EVEREST_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 3 misfire count EVEREST_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 4 misfire count EVEREST_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 5 misfire count EVEREST_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 6 misfire count EVEREST_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 7 misfire count EVEREST_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 8 misfire count EVEREST_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder head temperature EVEREST_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder head temperature EVEREST_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Cylinder head temperature EVEREST_PCM_CYL_HEAD_T_CORRConfirmed

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x168E = 5774 → 577464 = 90.21875 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Cylinder head temperature, alternate EVEREST_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2003 to 2026.

Cylinder head temperature, sensor 2 EVEREST_PCM_CYL_HEAD_T_SENS_2_RAWConfirmed

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x15B1 = 5553 → 555364 = 86.765625 °C

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Distance since DTC clear EVEREST_DIST_DTC_CLRConfirmed

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x19B2 = 6578 → 6,578 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Distance with MIL EVEREST_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

DTC counter EVEREST_DTC_CNTConfirmed

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2003 to 2024, 2026.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Engine load EVEREST_ENG_LOAD_PCTConfirmed

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine load, actual EVEREST_ENG_LOAD_ACTConfirmed

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

0x0024 = 36 → 36×100255 = 14.117647 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Engine oil pressure - desired EVEREST_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2003 to 2024, 2026. Not supported for 2025.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Engine oil temperature EVEREST_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2003 to 2026.

Engine oil temperature, alternate EVEREST_EOT_F45CConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x34 = 52 → 52−40 = 12 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine oil temperature, variant 2 EVEREST_EOT_VAR_2

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Engine reference torque EVEREST_PCM_ENG_REFERENCE_TRQConfirmed

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x01FC = 508 → 508 N·m

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024 to 2025.

Engine run time EVEREST_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Engine run time EVEREST_RUN_TIMEConfirmed

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x04AE = 1198 → 1,198 s

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Engine speed EVEREST_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0C61 = 3169 → 31694 = 792.25 rpm

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Evaporative pressure sensor voltage EVEREST_EVAP_V

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge EVEREST_EVAP_PURGE_CMDConfirmed

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x11F0 = 4592 → 4592×10032768 = 14.013672 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Exhaust back pressure EVEREST_EXH_BACK_P

  • Service 22DID 1445
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29800
Range
0 to 2375 psi
Unit
psi

In testing for 2003 to 2026.

Exhaust gas recirculation EVEREST_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation cooler inlet temperature EVEREST_EGR_COOLER_INLET_T

  • Service 22DID 0569
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation cooler outlet temperature EVEREST_EGR_COOLER_OUTLET_T

  • Service 22DID 055D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation duty cycle EVEREST_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation inlet temperature EVEREST_EGR_INLET_T

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2026.

Exhaust gas recirculation open EVEREST_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation temperature EVEREST_EGR_T

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation temperature EVEREST_EGR_T_7E0_7E0Confirmed

  • Service 22DID F46B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

0x4000 = 16384 → 1638410−40 = 1,598.4 °C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Exhaust gas recirculation temperature a EVEREST_EGR_T_115F

  • Service 22DID 115F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2026.

Exhaust gas recirculation throttle position signal EVEREST_EGR_THROTTLE_POS_SIG

  • Service 22DID 096C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation valve position measured EVEREST_EGR_VLV_POS_MEAS

  • Service 22DID 09FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation valve position, desired EVEREST_EGR_VLV_POS_DES

  • Service 22DID 09D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas temperature 1 EVEREST_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature 2 EVEREST_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature after turbo, before oxidation catalyst EVEREST_EGT_PRE_DOC

  • Service 22DID 0991
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature, bank 1 EVEREST_EGT_B1Confirmed

  • Service 22DID F478
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

0x0105 = 261 → 26110−40 = -13.9 °C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Fuel pressure sensor voltage, low EVEREST_LPFP_SENS_VConfirmed

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pressure, low actual EVEREST_LPFP_ACTConfirmed

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

0x036D = 877 → 877×10000137892 = 63.600499 psi

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel pressure, low desired EVEREST_LPFP_DESConfirmed

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

0x9F = 159 → 159×4351000 = 69.165 psi

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel pump duty cycle, low pressure EVEREST_LPFP_DUTYConfirmed

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x1D67 = 7527 → 7527×258192 = 22.970581 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel pump pulse width, bank 2 EVEREST_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2003 to 2026.

Fuel rail pressure, desired EVEREST_HPFP_DESConfirmed

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0012 = 18 → 18×10 = 180 kPa

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel rail sensor voltage, high pressure EVEREST_HPFP_VConfirmed

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel trim, long term EVEREST_LTFTConfirmed

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x83 = 131 → 131×100128−100 = 2.34375 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Fuel trim, short term EVEREST_STFTConfirmed

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x7D = 125 → 125×100128−100 = -2.34375 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Generator control EVEREST_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024, 2026. Not supported for 2025.

Generator current EVEREST_GEN_CURRENTConfirmed

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

0xF880 = -1920 → -1920×78150000 = -29.9904 A

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Glow plug, commanded status EVEREST_GLOW_PLUG_CMD_STATConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

0x00 = 0 → 0−4 = -4

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Grill shutter duty cycle EVEREST_GRILL_SHUT_DCConfirmed

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xB2 = 178 → 178×100255 = 69.803922 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Grill shutter position EVEREST_GRILL_SHUTTER_POSConfirmed

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xBD = 189 → 189×100255 = 74.117647 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ignition correction, cylinder 1 EVEREST_IGN_CORR_CYL1Confirmed

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Ignition timing, cylinder 1 EVEREST_IGN_TIM_CYL1Confirmed

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

0x0013 = 19 → 194 = 4.75 °

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

In car temperature EVEREST_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2003 to 2026.

Injection mode EVEREST_INJ_MODEConfirmed

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

0x07 = 7 → 7

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Injector impulse width EVEREST_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2003 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2025.

Intake air temperature 1 EVEREST_IAT_1

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Intake air temperature 2 EVEREST_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2003 to 2026.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake temperature fault EVEREST_IAT_FAULTConfirmed

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Intake temperature sensor voltage EVEREST_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Intake temperature, alternate EVEREST_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x5E = 94 → 94−40 = 54 °C

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Knock counter, cylinder 1 EVEREST_PCM_CYL_1_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 2 EVEREST_PCM_CYL_2_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 3 EVEREST_PCM_CYL_3_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 4 EVEREST_PCM_CYL_4_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 5 EVEREST_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Knock counter, cylinder 6 EVEREST_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock sensor, 1 EVEREST_KS1_RAWConfirmed

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0028 = 40 → 40

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock sensor, 2 EVEREST_KS2_RAWConfirmed

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0026 = 38 → 38

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Lambda correction EVEREST_CL_LCConfirmed

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

0x0000 = 0 → 08192 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Lambda, commanded EVEREST_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Low oil pressure switch EVEREST_LOW_OIL_P_SWITCHConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Manifold absolute pressure, high resolution EVEREST_MAP_HIRESConfirmed

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

0x006E = 110 → 1104 = 27.5 kPa

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Manifold air temperature EVEREST_MANIFOLD_AIR_T

  • Service 22DID 16E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2003 to 2026.

Manifold pressure EVEREST_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

0x2D = 45 → 45×1000068947 = 6.526752 psi

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Manifold pressure sensor voltage EVEREST_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Manifold temperature EVEREST_MCTConfirmed

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

0x57 = 87 → 87 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024.

Mass airflow sensor frequency EVEREST_MASS_AIRFLOW_SENS

  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 Hz
Unit
Hz

In testing for 2003 to 2026.

Misfire acceleration, cylinder 1 EVEREST_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 2 EVEREST_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 3 EVEREST_PCM_MISF_ACCEL_CYL3_NORMConfirmed

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 4 EVEREST_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 5 EVEREST_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Misfire acceleration, cylinder 6 EVEREST_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire events, latest cycle EVEREST_PCM_MISF_EVENTS_LATEST_CYCConfirmed

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000001 = 1 → 1

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Navigation altitude EVEREST_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Navigation heading EVEREST_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2003 to 2026.

O2 sensor voltage, rear EVEREST_RO2_VConfirmed

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Octane adjustment EVEREST_OARConfirmed

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Oil life remaining EVEREST_PCM_ENG_OIL_LIFE_REMConfirmed

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x2C = 44 → 44 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Oil pressure EVEREST_PCM_ENG_EOP_RAWConfirmed

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

0x012D = 301 → 301 kPa

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Sump oil temperature measured EVEREST_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Throttle angle, actual EVEREST_ETC_ANG_ACTConfirmed

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle angle, desired EVEREST_ETC_ANG_DESConfirmed

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle control trim angle, learned EVEREST_ETC_TRIM_LRNConfirmed

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle inlet pressure EVEREST_TIP_ABSConfirmed

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

0x2F92 = 12178 → 12178×3733441 = 13.474059 psi

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle inlet pressure sensor voltage EVEREST_TIP_VConfirmed

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle inlet pressure, desired EVEREST_TIP_DES_ABSConfirmed

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

0x2F26 = 12070 → 12070×3733441 = 13.354565 psi

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Time since last oil change EVEREST_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2003 to 2026.

Torque converter slip EVEREST_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2003 to 2026.

Torque into torque converter EVEREST_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2003 to 2024, 2026. Not supported for 2025.

Torque into torque converter EVEREST_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2026.

Torque request EVEREST_TRQ_CTRL_REQConfirmed

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Total misfire count EVEREST_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Transfer case fluid temperature EVEREST_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2003 to 2026.

Transmission fluid temperature, variant 1 EVEREST_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2003 to 2024, 2026. Not supported for 2025.

Transmission fluid temperature, variant 2 EVEREST_ATF_T_VAR_2

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Transmission fluid temperature, variant 5 EVEREST_ATF_T_VAR_5

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2003 to 2026.

Transmission fluid temperature, variant 6 EVEREST_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Turbo boost EVEREST_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2003 to 2026.

Turbo inlet pressure EVEREST_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2003 to 2024, 2026. Not supported for 2025.

Variable geometry turbo duty cycle EVEREST_VGT_DUTY

  • Service 22DID 096D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Warm-ups since DTC clear EVEREST_WARMUP_CLRConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xE5 = 229 → 229

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Wastegate control EVEREST_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Wastegate duty cycle EVEREST_WGDCConfirmed

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10032768 = 0 %

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2024.

AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost bressure A control status BP_ASAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2024.

Boost bressure A control status BP_BSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 76 to 77 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_B_OLOpen loop
2BP_B_CLClosed loop
3BP_B_FAULTFault

Confirmed for 2024.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2025.

Fuel

Air/fuel ratio EVEREST_AIR_FUEL_RATConfirmed

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

0x7E4A = 32330 → 32330×0.000446787 = 14.444624

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Cylinder 1 fuel quantity EVEREST_CYL_1_FUEL_QTY

  • Service 22DID 04AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2026.

Cylinder 2 fuel quantity EVEREST_CYL_2_FUEL_QTY

  • Service 22DID 04AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 3 fuel quantity EVEREST_CYL_3_FUEL_QTY

  • Service 22DID 04AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2026.

Cylinder 4 fuel quantity EVEREST_CYL_4_FUEL_QTY

  • Service 22DID 04AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2026.

Cylinder 5 fuel quantity EVEREST_CYL_5_FUEL_QTY

  • Service 22DID 04AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Cylinder 6 fuel quantity EVEREST_CYL_6_FUEL_QTY

  • Service 22DID 04AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2003 to 2026.

Dilution of oil with fuel EVEREST_DILUTION_OIL_FUEL

  • Service 22DID 054C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2026.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024.

Engine fuel rate EVEREST_ENG_FUEL_RATEConfirmed

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

0x0000 = 0 → 020 = 0 L

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2024 to 2025.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Fuel correction, cylinder 1 EVEREST_FUEL_CORR_CYL_1

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2026.

Fuel correction, cylinder 2 EVEREST_FUEL_CORR_CYL_2

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2026.

Fuel correction, cylinder 3 EVEREST_FUEL_CORR_CYL_3

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2026.

Fuel correction, cylinder 4 EVEREST_FUEL_CORR_CYL_4

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2026.

Fuel correction, cylinder 5 EVEREST_FUEL_CORR_CYL_5

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2024, 2026. Not supported for 2025.

Fuel correction, cylinder 6 EVEREST_FUEL_CORR_CYL_6

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2003 to 2026.

Fuel injection impulse width EVEREST_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2003 to 2026.

Fuel level EVEREST_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel level EVEREST_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Fuel pump duty cycle EVEREST_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2003 to 2026.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Fuel rail pressure control EVEREST_FUEL_RAIL_P_CTRL

  • Service 22DID 03C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2003 to 2026.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Fuel tank level EVEREST_FLI_720

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2025.

Fuel tank pressure EVEREST_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2003 to 2026.

Fuel temperature EVEREST_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Fuel temperature a EVEREST_FUEL_T_7E0Confirmed

  • Service 22DID 0429
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x03E3 = 995 → 99564 = 15.546875 °C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Low side fuel rail pressure EVEREST_LOW_SIDE_FUEL_RAIL_P

  • Service 22DID 064E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 kPa
Unit
kPa

In testing for 2003 to 2026.

Mass fuel, desired EVEREST_MASS_FUEL_DES

  • Service 22DID 1412
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2003 to 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Volume fuel, desired EVEREST_VOLUME_FUEL_DES

  • Service 22DID 1411
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2003 to 2026.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Lights

Exterior lighting state EVEREST_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

High beam status EVEREST_HIGHBEAM_STATUS

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Movement

Accelerator pedal position EVEREST_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2003 to 2026.

Fan speed sensor EVEREST_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2003 to 2026.

Fan speed, desired EVEREST_FAN_SPD_DESConfirmed

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×4013107 = 0 %

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Front left wheel speed EVEREST_FL_VSSConfirmed

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024. In testing for 2003 to 2023, 2026. Not supported for 2025.

Front right wheel speed EVEREST_FR_VSSConfirmed

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Lateral acceleration EVEREST_LAT_GConfirmed

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

0x0000 = 0 → 050 = 0

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Lateral angle, raw count EVEREST_LAT_ANGConfirmed

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2026. Not supported for 2025.

Navigation speed EVEREST_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

In testing for 2003 to 2026.

Rear left wheel speed EVEREST_RL_VSSConfirmed

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024. In testing for 2003 to 2023, 2026. Not supported for 2025.

Rear right wheel speed EVEREST_RR_VSSConfirmed

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Vehicle speed EVEREST_VSSConfirmed

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024. Supported for 2025.

Vehicle speed, high resolution EVEREST_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2024. Supported for 2025.

Tires

4 wheel drive engaged EVEREST_4_WHL_DRIVE_ENGAGED

  • Service 22DID A211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2003 to 2026.

Front left tire pressure EVEREST_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right tire pressure EVEREST_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left outer tire pressure EVEREST_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right outer tire pressure EVEREST_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Tire pressure warning EVEREST_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every15 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Tire temperature EVEREST_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Transmission

All-wheel drive clutch diagnostic signal EVEREST_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

All-wheel drive clutch, commanded control signal EVEREST_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Axle gear ratio, measured EVEREST_AXLE_GEAR_RATIO_MEASConfirmed

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Converter speed ratio EVEREST_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2003 to 2024, 2026. Not supported for 2025.

Current gear EVEREST_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → 1

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Gear EVEREST_GEAR_7E1

  • Service 22DID 1E1F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047
Unit
Number

In testing for 2003 to 2024, 2026. Supported for 2025.

Gear ratio, commanded EVEREST_PCM_CMD_TRANS_GEAR_RATIOConfirmed

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

0x2262 = 8802 → 8802×1665535 = 2.148959

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Gear, engaged EVEREST_GEAR_ENGConfirmed

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

0x01 = 1 → 1

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Shift gear EVEREST_GEAR_SHFT

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

In testing for 2003 to 2023, 2026. Supported for 2025. Not supported for 2024.

Torque converter line pressure EVEREST_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2003 to 2026.

Torque into torque converter, variant 2 EVEREST_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2024, 2026. Not supported for 2025.

Transmission fluid fluid quality EVEREST_TRANS_FLUID_FLUID

  • Service 22DID 180F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2026.

Transmission gear EVEREST_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2026.

Transmission gear EVEREST_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2026.

Transmission gear ratio EVEREST_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2003 to 2026.

Transmission odometer EVEREST_TRANS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2003 to 2024, 2026. Supported for 2025.

Transmission oil temperature EVEREST_TOTConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-40 to 255 °C
Unit
°C

0x039A = 922 → 92216 = 57.625 °C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Transmission output shaft speed EVEREST_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2003 to 2026.

Transmission pressure, commanded EVEREST_PCM_CMD_TRANS_MAIN_LINE_PConfirmed

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

0x00CD = 205 → 205×2 = 410 kPa

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Trips

Distance since last complete regeneration EVEREST_DIST_SINCE_COMPLETE

  • Service 22DID 0434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×625
Range
0 to 4026531 mi
Unit
mi

In testing for 2003 to 2024, 2026. Not supported for 2025.

Distance since last oil change EVEREST_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2024, 2026. Not supported for 2025.

Distance to empty, calculated EVEREST_DTEConfirmed

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

0x07AA = 1962 → 196210 = 196.2 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Distance to empty, displayed EVEREST_DTE_DISPConfirmed

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

0x0131 = 305 → 30510 = 30.5 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Odometer EVEREST_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2003 to 2023, 2026. Not supported for 2024 to 2025.

Odometer EVEREST_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2003 to 2024, 2026. Not supported for 2025.

Odometer EVEREST_ODO_7E0Confirmed

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000873 = 2163 → 2,163 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024 to 2025.

Odometer, brake module EVEREST_ABS_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x00439C = 17308 → 17,308 km

Confirmed for 2024. In testing for 2003 to 2023, 2026. Supported for 2025.

Odometer, instrument panel EVEREST_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2003 to 2023, 2026. Supported for 2025. Not supported for 2024.

Total distance, lifetime EVEREST_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2003 to 2026.

Trip distance EVEREST_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2003 to 2023, 2026. Supported for 2025. Not supported for 2024.

Vehicle odometer EVEREST_PCM_VEH_ODOConfirmed

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x0001011C = 65820 → 6582010 = 6,582 km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.