Ford Ranger

Parameters

The Ford Ranger has 375 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage RANGER_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7C = 124 → 12420+6 = 12.2 V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age RANGER_12V_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

0x0269 = 617 → 617×24 = 14,808 h

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

12V battery current RANGER_VEH_BAT_CURRENTConfirmed

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

0x51 = 81 → 81−127 = -46 A

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

12V battery state of charge RANGER_12V_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x4B = 75 → 75 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

12V battery temperature RANGER_12V_TConfirmed

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2020, 2022 to 2026

Example reply from a 2021 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

0x4D = 77 → 77−40 = 37 °C

Confirmed for 2021. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2022, 2024.

12V battery voltage RANGER_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7C = 124 → 12420+6 = 12.2 V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Battery capacity too low for start/stop RANGER_BAT_CAP_TOO_LOWConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery current too high for start/stop RANGER_BAT_CURRENT_TOO_HIGHConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery current, predicted RANGER_BAT_CURRENTConfirmed

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

0x000035 = 53 → 534 = 13.25 A

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery percentage, state of charge RANGER_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Battery quiescent current, low range RANGER_BAT_QUIESCENTConfirmed

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

0x0820 = 2080 → 20802−1000 = 40 mA

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery refresh cycle in progress for start/stop RANGER_BAT_REFRESH_CYCLEConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery state detection status RANGER_BAT_ST_DETECTIONConfirmed

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery state of charge too low for start/stop RANGER_BAT_ST_CHG_TOO_LOWConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery temperature too low for auto stop RANGER_BAT_T_TOO_LOW_AUTOConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery voltage RANGER_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Battery voltage too low for auto restart RANGER_BAT_V_TOO_LOW_AUTOConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery voltage too low for cold cranking capability RANGER_BAT_V_TOO_LOW_COLDConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Battery voltage too low for start/stop RANGER_BAT_V_TOO_LOW_STARTConfirmed

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Charge air cooler temperature RANGER_CHG_AIR_COOLER_T

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Charge air temperature RANGER_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Commanded generator voltage RANGER_CMD_GEN_VConfirmed

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

0x54CC = 21708 → 21708×0.000488 = 10.593504 V

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2013 to 2014, 2018 to 2026. Supported for 2008 to 2009, 2011 to 2012.

Normalized cumulative charge when ignition is on RANGER_NORM_CUM_CHG_IGN_ONConfirmed

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x012F = 303 → 30310 = 30.3

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Normalized cumulative discharge from battery with engine off RANGER_NORM_CUM_DCHG_BAT_OFFConfirmed

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x00C1 = 193 → 19310 = 19.3

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Normalized cumulative discharge from battery with engine on RANGER_NORM_CUM_DCHG_BAT_ONConfirmed

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x0041 = 65 → 6510 = 6.5

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Second battery current RANGER_VEH_BAT_B_CURRENTConfirmed

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

0x0000 = 0 → 032 = 0 A

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Second battery voltage RANGER_VEH_BAT_B_VConfirmed

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

0x7C = 124 → 12420+6 = 12.2 V

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Climate

A/C compressor pressure RANGER_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

A/C compressor pressure sensor voltage RANGER_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

A/C compressor, state RANGER_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

A/C refrigerant pressure RANGER_PCM_A_C_REFRIG_PConfirmed

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

0x02B2 = 690 → 690 kPa

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012 to 2014, 2018, 2020, 2022, 2024, 2026. Supported for 2011, 2019, 2021, 2023, 2025.

Ambient temperature sensor voltage RANGER_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Ambient temperature, alternate RANGER_AAT_ALTConfirmed

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x7C = 124 → 1242−40 = 22 °C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2013 to 2014, 2018, 2020, 2022, 2024, 2026. Supported for 2008 to 2009, 2011 to 2012, 2019, 2021, 2023, 2025.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012 to 2014, 2018 to 2022, 2024 to 2026. Supported for 2006, 2008 to 2009, 2011, 2023.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2020, 2022. Supported for 2019, 2021, 2023 to 2024.

Steering wheel angle RANGER_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×6.25
Range
-790 to 790 °
Unit
°

In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2014, 2018 to 2019, 2021, 2024.

Pedals

Accelerator pedal position (relative) APP_RSAE J1979Confirmed

  • Service 01PID 5A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013, 2018, 2020, 2022, 2024. Supported for 2011 to 2012, 2014, 2019, 2021, 2023, 2025.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013, 2018, 2020, 2022, 2024. Supported for 2011 to 2012, 2014, 2019, 2021, 2023, 2025.

Doors

Driver door ajar RANGER_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Hood ajar? RANGER_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Lock status RANGER_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Passenger door ajar? RANGER_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Rear left door ajar? RANGER_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Rear right door ajar? RANGER_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Trunk ajar? RANGER_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018 to 2026. Supported for 2008 to 2009, 2014.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018, 2020 to 2021, 2024. Supported for 2019, 2022 to 2023, 2025.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018, 2020 to 2021, 2024. Supported for 2019, 2022 to 2023, 2025.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2024. Supported for 2008 to 2009, 2011 to 2014, 2018 to 2020, 2022 to 2023, 2025 to 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013 to 2014, 2018, 2020 to 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2023, 2026.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2022, 2024. Supported for 2008 to 2009, 2019, 2021, 2023, 2025 to 2026.

Accelerator position RANGER_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual engine percent torque RANGER_PCM_ACT_ENG_PCT_TRQConfirmed

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

0x7D = 125 → 125−125 = 0 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2024. Supported for 2019, 2021 to 2023, 2025.

Air conditioning pressure RANGER_AC_P_7E0Confirmed

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

0x00 = 0 → 0×12.156863 = 0 kPa

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2012 to 2014, 2018, 2020 to 2021, 2024 to 2025. Supported for 2006, 2008 to 2009, 2011, 2019, 2022 to 2023.

Alternator current output RANGER_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013 to 2014, 2020, 2024. Supported for 2008 to 2009, 2011 to 2012, 2018 to 2019, 2021 to 2023, 2025 to 2026.

Barometric pressure RANGER_BAROConfirmed

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

0x0180 = 384 → 384×61516963 = 13.922066 psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Barometric pressure RANGER_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Barometric pressure sensor voltage RANGER_BARO_VConfirmed

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

0x02EE = 750 → 750×51023 = 3.665689 V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Battery current RANGER_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Boost RANGER_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Bypass valve RANGER_BPV_OPENConfirmed

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

0x00 = 0 → 0255 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012 to 2014, 2018 to 2022, 2024 to 2026. Supported for 2006, 2008 to 2009, 2011, 2023.

Camshaft position error, exhaust RANGER_VCT_EXH_ERRConfirmed

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position error, intake RANGER_VCT_INT_ERRConfirmed

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, exhaust actual RANGER_VCT_EXH_ACTConfirmed

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, exhaust desired RANGER_VCT_EXH_DESConfirmed

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, intake actual RANGER_VCT_INT_ACTConfirmed

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, intake desired RANGER_VCT_INT_DESConfirmed

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft solenoid duty cycle, exhaust RANGER_VCT_EXH_DUTYConfirmed

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft solenoid duty cycle, intake RANGER_VCT_INT_DUTYConfirmed

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Catalyst temperature RANGER_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x100B = 4107 → 410710−40 = 370.7 °C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2008 to 2009, 2018 to 2019, 2021 to 2026.

Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed

  • Service 01PID 3E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2022.

Charge air temperature RANGER_CATConfirmed

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

0x04FE = 1278 → 127864−40 = -20.03125 °C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Charge air temperature sensor voltage RANGER_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2008 to 2009, 2011 to 2012, 2018 to 2019, 2021 to 2022.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Commanded generator duty RANGER_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2011 to 2012, 2018 to 2019, 2021 to 2022.

Coolant temperature RANGER_ECTConfirmed

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x082E = 2094 → 209464 = 32.71875 °C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Current gear RANGER_GEARConfirmed

The automatic transmission gear. Numbers aren't yet mapped to named gears.

  • Service 22DID 1E12
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018 to 2025. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2026. Not supported for 2006, 2008, 2012 to 2013.

Cylinder 1 misfire count RANGER_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 2 misfire count RANGER_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 3 misfire count RANGER_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 4 misfire count RANGER_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 5 misfire count RANGER_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 6 misfire count RANGER_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 7 misfire count RANGER_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 8 misfire count RANGER_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_PCM_CYL_HEAD_T_CORRConfirmed

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x067F = 1663 → 166364 = 25.984375 °C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Cylinder head temperature, alternate RANGER_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature, sensor 2 RANGER_PCM_CYL_HEAD_T_SENS_2_RAWConfirmed

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x0B66 = 2918 → 291864 = 45.59375 °C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Distance since DTC clear RANGER_DIST_DTC_CLRConfirmed

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x142A = 5162 → 5,162 km

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Distance with MIL RANGER_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Driver's demand engine torque TQ_DDSAE J1979Confirmed

  • Service 01PID 61
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020. Supported for 2019, 2021 to 2025.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2011 to 2012, 2018 to 2019, 2021 to 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012 to 2014, 2018 to 2022, 2024 to 2026. Supported for 2006, 2008 to 2009, 2011, 2023.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020.

Engine load RANGER_ENG_LOAD_PCTConfirmed

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Engine load, actual RANGER_ENG_LOAD_ACTConfirmed

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

0x0000 = 0 → 0×100255 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Engine oil pressure RANGER_EOPConfirmed

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Supported for 2021. Not supported for 2006, 2008, 2012 to 2013, 2019, 2024.

Engine oil pressure - desired RANGER_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. Supported for 2019, 2021 to 2024.

Engine oil temperature RANGER_EOTConfirmed

  • Service 22DID 1310
  • Module7DF
  • Every30 s
  • Testing

Example reply from a 2014 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x12 = 18 → 18

Confirmed for 2012 to 2014. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2020, 2023, 2025 to 2026. Not supported for 2006, 2008, 2018 to 2019, 2021 to 2022, 2024.

Engine reference torque RANGER_PCM_ENG_REFERENCE_TRQConfirmed

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x02B2 = 690 → 690 N·m

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020. Supported for 2019, 2021, 2023 to 2025.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2013 to 2014, 2018, 2020, 2022, 2024. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2021, 2023, 2025 to 2026.

Engine run time RANGER_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Engine speed RANGER_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Evaporative pressure sensor voltage RANGER_EVAP_VConfirmed

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x078B = 1931 → 19311000 = 1.931 V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Evaporative purge RANGER_EVAP_PURGE_CMDConfirmed

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10032768 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Exhaust gas recirculation RANGER_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas recirculation duty cycle RANGER_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas recirculation open RANGER_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust gas recirculation temperature RANGER_EGR_T

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas temperature 1 RANGER_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas temperature 2 RANGER_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel injection timing FUEL_TIMINGSAE J1979Confirmed

Start of main fuel injection relative to Top Dead Center (TDC). Positive degrees indicate before TDC, negative degrees indicate after TDC.

  • Service 01PID 5D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−38665
Range
-210 to 301.992 °
Unit
°

Confirmed for 2020. Supported for 2019, 2021 to 2025.

Fuel pressure sensor voltage, low RANGER_LPFP_SENS_VConfirmed

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pressure, low actual RANGER_LPFP_ACTConfirmed

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

0x0329 = 809 → 809×10000137892 = 58.669103 psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pressure, low desired RANGER_LPFP_DESConfirmed

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

0x9F = 159 → 159×4351000 = 69.165 psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pump duty cycle, low pressure RANGER_LPFP_DUTYConfirmed

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x1953 = 6483 → 6483×258192 = 19.784546 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pump pulse width, bank 2 RANGER_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2013 to 2014. Supported for 2011 to 2012, 2019, 2021 to 2026.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.

  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2020. Supported for 2019, 2021 to 2025.

Fuel rail pressure, desired RANGER_HPFP_DESConfirmed

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0024 = 36 → 36×10 = 360 kPa

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Fuel rail sensor voltage, high pressure RANGER_HPFP_VConfirmed

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Fuel trim, long term RANGER_LTFTConfirmed

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x7B = 123 → 123×100128−100 = -3.90625 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel trim, short term RANGER_STFTConfirmed

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x75 = 117 → 117×100128−100 = -8.59375 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Generator control RANGER_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Generator current RANGER_GEN_CURRENTConfirmed

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

0xF880 = -1920 → -1920×78150000 = -29.9904 A

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Grill shutter duty cycle RANGER_GRILL_SHUT_DCConfirmed

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Grill shutter position RANGER_GRILL_SHUTTER_POSConfirmed

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Ignition correction, cylinder 1 RANGER_IGN_CORR_CYL1Confirmed

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Ignition timing, cylinder 1 RANGER_IGN_TIM_CYL1Confirmed

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

0x0004 = 4 → 44 = 1 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

In car temperature RANGER_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Injection mode RANGER_INJ_MODEConfirmed

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

0x07 = 7 → 7

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Injector impulse width RANGER_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013 to 2014. Supported for 2006, 2008 to 2009, 2011 to 2012, 2018 to 2026.

Intake air temperature 2 RANGER_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013 to 2014, 2020. Supported for 2008 to 2009, 2011 to 2012, 2018 to 2019, 2021 to 2026.

Intake temperature fault RANGER_IAT_FAULTConfirmed

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Intake temperature sensor voltage RANGER_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

0x0174 = 372 → 372×51023 = 1.818182 V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Intake temperature, alternate RANGER_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3C = 60 → 60−40 = 20 °C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Knock counter, cylinder 1 RANGER_PCM_CYL_1_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 2 RANGER_PCM_CYL_2_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 3 RANGER_PCM_CYL_3_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 4 RANGER_PCM_CYL_4_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 5 RANGER_PCM_CYL_5_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 6 RANGER_PCM_CYL_6_KNK_COMB_PERF_CNTConfirmed

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock sensor, 1 RANGER_KS1_RAWConfirmed

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0017 = 23 → 23

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock sensor, 2 RANGER_KS2_RAWConfirmed

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0013 = 19 → 19

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Lambda correction RANGER_CL_LCConfirmed

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

0x0000 = 0 → 08192 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Lambda, commanded RANGER_CLConfirmed

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

0x5536 = 21814 → 2181432768 = 0.66571

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Manifold absolute pressure, high resolution RANGER_MAP_HIRESConfirmed

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

0x0054 = 84 → 844 = 21 kPa

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Manifold pressure RANGER_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Manifold pressure sensor voltage RANGER_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Manifold temperature RANGER_MCTConfirmed

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

0x3E = 62 → 62 °C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2024 to 2025.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2024 to 2025.

Misfire acceleration, cylinder 1 RANGER_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 2 RANGER_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 3 RANGER_PCM_MISF_ACCEL_CYL3_NORMConfirmed

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 4 RANGER_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 5 RANGER_PCM_MISF_ACCEL_CYL5_NORMConfirmed

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 6 RANGER_PCM_MISF_ACCEL_CYL6_NORMConfirmed

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire events, latest cycle RANGER_PCM_MISF_EVENTS_LATEST_CYCConfirmed

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000001 = 1 → 1

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Navigation altitude RANGER_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Navigation heading RANGER_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

O2 sensor voltage, rear RANGER_RO2_VConfirmed

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Octane adjustment RANGER_OARConfirmed

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Oil life remaining RANGER_PCM_ENG_OIL_LIFE_REMConfirmed

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x3D = 61 → 61 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Oil pressure RANGER_PCM_ENG_EOP_RAWConfirmed

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

0x0062 = 98 → 98 kPa

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Shift gear RANGER_GEAR_SHFTConfirmed

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2019, 2021 to 2026. Not supported for 2006, 2008, 2012 to 2013, 2020.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2019, 2022, 2024 to 2025. Supported for 2006, 2008 to 2009, 2021, 2023, 2026.

Sump oil temperature measured RANGER_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Throttle angle, actual RANGER_ETC_ANG_ACTConfirmed

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle angle, desired RANGER_ETC_ANG_DESConfirmed

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle control trim angle, learned RANGER_ETC_TRIM_LRNConfirmed

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle inlet pressure RANGER_TIP_ABSConfirmed

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

0x3113 = 12563 → 12563×3733441 = 13.900033 psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Throttle inlet pressure sensor voltage RANGER_TIP_VConfirmed

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Throttle inlet pressure, desired RANGER_TIP_DES_ABSConfirmed

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

0x3008 = 12296 → 12296×3733441 = 13.604617 psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Time since last oil change RANGER_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque converter slip RANGER_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque into torque converter RANGER_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque into torque converter RANGER_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque request RANGER_TRQ_CTRL_REQConfirmed

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Total Engine Run Time RUN_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Total Idle Run Time IDLE_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Total misfire count RANGER_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Total Run Time With PTO Active PTO_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Transfer case fluid temperature RANGER_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission fluid temperature, variant 1 RANGER_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission fluid temperature, variant 6 RANGER_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission oil temperature RANGER_TOTConfirmed

  • Service 22DID 1E1C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2013, 2020.

Turbo boost RANGER_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Turbo inlet pressure RANGER_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2020, 2024. Supported for 2018 to 2019, 2021 to 2023, 2025.

Warm-ups since DTC clear RANGER_WARMUP_CLRConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x3C = 60 → 60

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Wastegate control RANGER_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Wastegate duty cycle RANGER_WGDCConfirmed

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10032768 = 0 %

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost bressure A control status BP_ASAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2024.

Boost bressure A control status BP_BSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 76 to 77 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_B_OLOpen loop
2BP_B_CLClosed loop
3BP_B_FAULTFault

Confirmed for 2024.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

Engine Percent Torque At Idle, Point 1 TQ_MAX1SAE J1979Confirmed

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 2 TQ_MAX2SAE J1979Confirmed

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 3 TQ_MAX3SAE J1979Confirmed

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 4 TQ_MAX4SAE J1979Confirmed

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 5 TQ_MAX5SAE J1979Confirmed

  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 39 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2024 to 2025.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2024 to 2025.

Total Engine Run Time supported? RUN_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Total Idle Run Time supported? IDLE_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Total Run Time With PTO Active supported? PTO_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Fuel

Air/fuel ratio RANGER_AIR_FUEL_RATConfirmed

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

0x0000 = 0 → 0×0.000446787 = 0

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2018, 2020 to 2022, 2024 to 2026. Supported for 2019, 2023.

Engine fuel rate RANGER_ENG_FUEL_RATEConfirmed

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

0x0000 = 0 → 020 = 0 L

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Fuel correction, cylinder 1 RANGER_FUEL_CORR_CYL_1

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel correction, cylinder 2 RANGER_FUEL_CORR_CYL_2

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel correction, cylinder 3 RANGER_FUEL_CORR_CYL_3

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel correction, cylinder 4 RANGER_FUEL_CORR_CYL_4

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel correction, cylinder 5 RANGER_FUEL_CORR_CYL_5

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel correction, cylinder 6 RANGER_FUEL_CORR_CYL_6

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel injection impulse width RANGER_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel level RANGER_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel pump duty cycle RANGER_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013 to 2014, 2018, 2020 to 2021, 2023 to 2026. Supported for 2008 to 2009, 2011 to 2012, 2019, 2022.

Fuel tank level RANGER_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every1 s

Example reply from a 2026 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xCF = 207 → 207×100255 = 81.176471 %

Confirmed for 2006, 2008, 2012 to 2014, 2018 to 2026. In testing for 1996 to 2005, 2007, 2009 to 2011, 2015 to 2017.

Fuel tank level RANGER_FLI_720

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing for 1996 to 2005, 2007, 2009 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020, 2023, 2025 to 2026. Not supported for 2019, 2021 to 2022, 2024.

Fuel tank pressure RANGER_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel temperature RANGER_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Lights

Exterior lighting state RANGER_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

High beam status RANGER_HIGHBEAM_STATUS

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Movement

Accelerator pedal position RANGER_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fan speed sensor RANGER_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fan speed, desired RANGER_FAN_SPD_DESConfirmed

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×4013107 = 0 %

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Navigation speed RANGER_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle speed RANGER_VSSConfirmed

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2012 to 2014, 2018 to 2020, 2022 to 2026. Supported for 2006, 2008 to 2009, 2011, 2021.

Vehicle speed, high resolution RANGER_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2013 to 2014, 2018, 2020, 2022, 2026. Supported for 2006, 2008 to 2009, 2011 to 2012, 2019, 2021, 2023 to 2025.

Tires

Front left tire pressure RANGER_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every30 s
  • Testing

Example reply from a 2026 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x034A = 842 → 84220 = 42.1 psi

Confirmed for 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2014, 2020.

Front right tire pressure RANGER_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every30 s
  • Testing

Example reply from a 2026 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x031D = 797 → 79720 = 39.85 psi

Confirmed for 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2014, 2020.

Rear left outer tire pressure RANGER_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every30 s
  • Testing

Example reply from a 2026 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x0354 = 852 → 85220 = 42.6 psi

Confirmed for 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2004, 2006, 2008, 2012 to 2014, 2020.

Rear right outer tire pressure RANGER_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every30 s
  • Testing

Example reply from a 2026 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x0336 = 822 → 82220 = 41.1 psi

Confirmed for 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2014, 2020.

Tire pressure warning RANGER_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every15 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Tire temperature RANGER_TYRE_TConfirmed

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x5C = 92 → 92−40 = 52 °C

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Transmission

All-wheel drive clutch diagnostic signal RANGER_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

All-wheel drive clutch, commanded control signal RANGER_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Axle gear ratio, measured RANGER_AXLE_GEAR_RATIO_MEASConfirmed

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Converter speed ratio RANGER_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Gear ratio, commanded RANGER_PCM_CMD_TRANS_GEAR_RATIOConfirmed

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Gear, engaged RANGER_GEAR_ENGConfirmed

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

0x01 = 1 → 1

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Torque converter line pressure RANGER_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission gear RANGER_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission gear ratio RANGER_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission output shaft speed RANGER_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission pressure, commanded RANGER_PCM_CMD_TRANS_MAIN_LINE_PConfirmed

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

0x00AF = 175 → 175×2 = 350 kPa

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Trips

Distance since last oil change RANGER_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Distance to empty, calculated RANGER_DTEConfirmed

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

0x0FC8 = 4040 → 404010 = 404 km

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Distance to empty, displayed RANGER_DTE_DISPConfirmed

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

0x0FCF = 4047 → 404710 = 404.7 km

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2019 to 2020, 2022 to 2026.

Odometer RANGER_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2020, 2023, 2025 to 2026. Not supported for 2006, 2008, 2012 to 2014, 2018 to 2019, 2021 to 2022, 2024.

Odometer RANGER_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2021, 2023, 2025 to 2026. Not supported for 2019, 2022, 2024.

Odometer RANGER_ODO_7E0Confirmed

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x005E2B = 24107 → 24,107 km

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Odometer, instrument panel RANGER_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Total distance, lifetime RANGER_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Trip distance RANGER_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Vehicle odometer RANGER_PCM_VEH_ODOConfirmed

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x0003ADB4 = 241076 → 24107610 = 24,107.6 km

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.