Parameters
The GMC Sierra 3500HD has 170 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Charge air cooler temperature sensor 1 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_1
- Service 22
DID 30AD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Charge air cooler temperature sensor 1 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_1_DA11
- Service 22
DID 30AD - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Charge air cooler temperature sensor 2 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_2
- Service 22
DID 30AE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Charge air cooler temperature sensor 2 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_2_DA11
- Service 22
DID 30AE - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Control module voltage SIERRA3500_M_CTRL_MODULE_V
- Service 22
DID 0042 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2007 to 2019.
Ignition 1 voltage SIERRA3500_IGN_1_V
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2007 to 2019.
Clocks
Time since engine start SIERRA3500_RUNTM
- Service 22
DID 11A1 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2014, 2024. Supported for 2020 to 2021.
Engine
1-2 shift error SIERRA3500_1_2_SHIFT_ERROR
- Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
1-2 shift time SIERRA3500_1_2_SHIFT_TIME
- Service 22
DID 1993 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
2-3 shift error SIERRA3500_2_3_SHIFT_ERROR
- Service 22
DID 1998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
2-3 shift time SIERRA3500_2_3_SHIFT_TIME
- Service 22
DID 1994 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
3-4 shift error SIERRA3500_3_4_SHIFT_ERROR
- Service 22
DID 1999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
3-4 shift time SIERRA3500_3_4_SHIFT_TIME
- Service 22
DID 1995 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
Air conditioning high side pressure SIERRA3500_AC_HIGH_SIDE_P
- Service 22
DID 1564 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 515.1 psi
- Unit
- psi
In testing for 2007 to 2019.
Air filter life remaining SIERRA3500_AIRFILT_LIFE
- Service 22
DID 36A7 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Air/fuel ratio, commanded SIERRA3500_AIR_FUEL_RAT_CMD
- Service 22
DID 119E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 1 SIERRA3500_BALANCE_RATE_CYL_1
- Service 22
DID 162F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 2 SIERRA3500_BALANCE_RATE_CYL_2
- Service 22
DID 1630 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 3 SIERRA3500_BALANCE_RATE_CYL_3
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 4 SIERRA3500_BALANCE_RATE_CYL_4
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 5 SIERRA3500_BALANCE_RATE_CYL_5
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 6 SIERRA3500_BALANCE_RATE_CYL_6
- Service 22
DID 1634 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 7 SIERRA3500_BALANCE_RATE_CYL_7
- Service 22
DID 1635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Balance rate, cylinder 8 SIERRA3500_BALANCE_RATE_CYL_8
- Service 22
DID 1636 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2007 to 2019.
Barometric pressure, V8 SIERRA3500_BAROMETRIC_P_V8
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Boost pressure: actual SIERRA3500_BP_ACT
- Service 22
DID 20E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Boost pressure: desired SIERRA3500_BP_DES
- Service 22
DID 328A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Boost pressure: desired SIERRA3500_BP_DES_DA11
- Service 22
DID 328A - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Calculated engine oil pressure SIERRA3500_EOP_CALC
- Service 22
DID 1C1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Calculated engine oil temperature SIERRA3500_EOT_CALC
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Cooling fan command SIERRA3500_COOLING_FAN_CMD
- Service 22
DID 3812 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Cooling fan motor command SIERRA3500_COOLING_FAN_MOTOR_CMD
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Diesel particulate filter, average filter inlet temperature during regeneration SIERRA3500_DPF_AVG_FLT_INLET_T_DURING_REGEN
- Service 22
DID 20F8 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 s
- Unit
- s
In testing for 2020 to 2026.
Diesel particulate filter, average regeneration duration SIERRA3500_DPF_AVG_REGEN_DURATION
- Service 22
DID 20F9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2040 s
- Unit
- s
In testing for 2020 to 2026.
Diesel particulate filter, calculated flow resistance SIERRA3500_DPF_CALCULATED_FLOW_RESISTANCE_KPA_L_S
- Service 22
DID 20F5 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, corrected pressure SIERRA3500_DPF_CORRECTED_PRES
- Service 22
DID 34D9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Diesel particulate filter, engine run time since last regeneration SIERRA3500_DPF_ENGINE_RUN_TIME_SINCE_LAST_REGEN_MIN
- Service 22
DID 20F3 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8738 min
- Unit
- min
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 1 SIERRA3500_DPF_EGT_1
- Service 22
DID 303A - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 2 SIERRA3500_DPF_EGT_2
- Service 22
DID 303B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 3 SIERRA3500_DPF_EGT_3
- Service 22
DID 30A9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 4 SIERRA3500_DPF_EGT_4
- Service 22
DID 0078 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 5 SIERRA3500_DPF_EGT_5
- Service 22
DID 30AB - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, number of completed regeneration events SIERRA3500_DPF_NUMBER_OF_COMPLETED_REGENS
- Service 22
DID 304B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, pressure sensor SIERRA3500_DPF_PRES_SNS
- Service 22
DID 3035 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Diesel particulate filter, regeneration reason SIERRA3500_DPF_REGEN_REASON
- Service 22
DID 303E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, regeneration status SIERRA3500_DPF_REGEN_STS
- Service 22
DID 3375 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Engine oil absolute pressure SIERRA3500_EOP_ABS
- Service 22
DID 2344 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Engine oil life remaining SIERRA3500_EO_LIFE_REMAINING
- Service 22
DID 4DC0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Engine oil pressure SIERRA3500_EOP
- Service 22
DID 2345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Engine oil pressure SIERRA3500_EOP_DA11
- Service 22
DID 1470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Engine oil pressure SIERRA3500_EOP_DA11_2
- Service 22
DID 1470 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure 2 SIERRA3500_EOP_2
Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.
- Service 22
DID 115C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -21.6 to 131.39 psi
- Unit
- psi
In testing for 2007 to 2019.
Engine oil pressure control solenoid valve command SIERRA3500_EOP_CTRL_SOLENOID_VALVE_CMD
- Service 22
DID 3318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2019.
Engine oil pressure, desired SIERRA3500_EOP_DES
- Service 22
DID 37A7 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil temperature SIERRA3500_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 005C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Engine oil temperature SIERRA3500_EOT_DA11
- Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Engine oil temperature SIERRA3500_EOT_DA11_2_2
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 005C - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine torque SIERRA3500_ENG_TQ
- Service 22
DID 19DE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2007 to 2019.
Engine torque SIERRA3500_ENG_TQ_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 N·m
- Unit
- N·m
In testing for 2007 to 2019.
Evaporative emissions purge SIERRA3500_EVAPORATIVE
- Service 22
DID 1170 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Exhaust gas recirculation duty cycle SIERRA3500_EGR_DUTY
- Service 22
DID 1171 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Exhaust gas recirculation voltage SIERRA3500_EGR_V
- Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2019.
Heated oxygen sensor SIERRA3500_HEATED_OXYGEN_SENS
- Service 22
DID 1145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mV
- Unit
- mV
In testing for 2007 to 2019.
Idle air control position SIERRA3500_IDLE_AIR_CTRL_POS
- Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Injector duty cycle bank 1 SIERRA3500_INJECTOR_DUTY_CYCLE_BANK_1
- Service 22
DID 12C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2007 to 2019.
Injector duty cycle bank 2 SIERRA3500_INJECTOR_DUTY_CYCLE_BANK_2
- Service 22
DID 12C4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2007 to 2019.
Injector pulse width, cylinder 1 SIERRA3500_INJ_WIDTH_CYL_1
- Service 22
DID 1193 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Injector pulse width, cylinder 7 SIERRA3500_INJ_WIDTH_CYL_7
- Service 22
DID 1199 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Injector pulse width, cylinder 8 SIERRA3500_INJ_WIDTH_CYL_8
- Service 22
DID 129A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Intake air temperature 2 SIERRA3500_IAT_2
- Service 22
DID 1538 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Knock retard SIERRA3500_KNOCK_RETARD
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1 °
- Unit
- °
In testing for 2007 to 2019.
Knock retard, alternate SIERRA3500_KNOCK_RETARD_ALT
- Service 22
DID 125D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2007 to 2019.
Knock sensor active counter SIERRA3500_KNOCK_SENS_ACTIVE
- Service 22
DID 125E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Last shift time SIERRA3500_LAST_SHIFT_TIME
- Service 22
DID 1992 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2007 to 2019.
Mass airflow sensor SIERRA3500_MAF
- Service 22
DID 0010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2007 to 2019.
Misfire current, cylinder 7 SIERRA3500_MIS_CURRENT_7
- Service 22
DID 11EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfire current, cylinder 8 SIERRA3500_MIS_CURRENT_8
- Service 22
DID 11ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 1 SIERRA3500_MIS_HISTORY_1
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 2 SIERRA3500_MIS_HISTORY_2
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 3 SIERRA3500_MIS_HISTORY_3
- Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 4 SIERRA3500_MIS_HISTORY_4
- Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 5 SIERRA3500_MIS_HISTORY_5
- Service 22
DID 11F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 6 SIERRA3500_MIS_HISTORY_6
- Service 22
DID 11F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 7 SIERRA3500_MIS_HISTORY_7
- Service 22
DID 11FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfire history, cylinder 8 SIERRA3500_MIS_HISTORY_8
- Service 22
DID 11FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 1 SIERRA3500_MISFIRES_C1_CUR
- Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 2 SIERRA3500_MISFIRES_C2_CUR
- Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 3 SIERRA3500_MISFIRES_C3_CUR
- Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 4 SIERRA3500_MISFIRES_C4_CUR
- Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 5 SIERRA3500_MISFIRES_C5_CUR
- Service 22
DID 11EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 6 SIERRA3500_MISFIRES_C6_CUR
- Service 22
DID 11EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Misfires, current, cylinder 7 SIERRA3500_MISFIRES_C7_CUR
- Service 22
DID 11EC - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 8 SIERRA3500_MISFIRES_C8_CUR
- Service 22
DID 11ED - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Outside air temperature SIERRA3500_AAT
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Particulate matter sensor soot accumulation SIERRA3500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION
- Service 22
DID 3635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Particulate matter sensor soot accumulation SIERRA3500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION_DA11
- Service 22
DID 3635 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Particulate matter sensor temperature SIERRA3500_PARTICULATE_MATTER_SNS_T
- Service 22
DID 3372 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2007 to 2019.
Particulate matter sensor temperature SIERRA3500_PARTICULATE_MATTER_SNS_T_DA11
- Service 22
DID 3372 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Pressure control solenoid current, actual SIERRA3500_P_CTRL_SOLENOID_ACT
- Service 22
DID 199E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2007 to 2019.
Pressure control solenoid current, reference SIERRA3500_P_CTRL_SOLENOID
- Service 22
DID 199F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2007 to 2019.
Remaining oil life SIERRA3500_REMAINING_OIL_LIFE
- Service 22
DID 119F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2007 to 2019.
Total knock retard SIERRA3500_TOTAL_KNOCK_RETARD
- Service 22
DID 12D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 114.75 °
- Unit
- °
In testing for 2007 to 2019.
Total misfire SIERRA3500_TOTAL_MISFIRE
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Transmission fluid temperature SIERRA3500_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1940 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Transmission fluid temperature, variant 1 SIERRA3500_ATF_T_VAR_1
- Service 22
DID 1940 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Transmission fluid temperature, variant 6 SIERRA3500_ATF_T_VAR_6
- Service 22
DID 280D - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Fuel
Ethanol content of fuel SIERRA3500_ETHANOL_CONTENT_FUEL
- Service 22
DID 0052 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Fuel consumption rate SIERRA3500_FUEL_RATE
- Service 22
DID 005E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L
- Unit
- L
In testing for 2007 to 2019.
Fuel injection, cylinder 1 SIERRA3500_FUEL_INJECTION_C1
- Service 22
DID 20AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 1 SIERRA3500_FUEL_INJECTION_C1_DA11
- Service 22
DID 20AC - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 2 SIERRA3500_FUEL_INJ_CYL_2
- Service 22
DID 20AD - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 2 SIERRA3500_FUEL_INJECTION_C2
- Service 22
DID 1194 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 2 SIERRA3500_FUEL_INJECTION_C2_DA11
- Service 22
DID 1194 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 3 SIERRA3500_FUEL_INJ_CYL_3
- Service 22
DID 20AE - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 3 SIERRA3500_FUEL_INJECTION_C3
- Service 22
DID 1195 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 3 SIERRA3500_FUEL_INJECTION_C3_DA11
- Service 22
DID 1195 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 4 SIERRA3500_FUEL_INJ_CYL_4
- Service 22
DID 20AF - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 4 SIERRA3500_FUEL_INJECTION_C4
- Service 22
DID 1196 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 4 SIERRA3500_FUEL_INJECTION_C4_DA11
- Service 22
DID 1196 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 5 SIERRA3500_FUEL_INJ_CYL_5
- Service 22
DID 20B0 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 5 SIERRA3500_FUEL_INJECTION_C5
- Service 22
DID 1197 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 5 SIERRA3500_FUEL_INJECTION_C5_DA11
- Service 22
DID 1197 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 6 SIERRA3500_FUEL_INJ_CYL_6
- Service 22
DID 20B1 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 6 SIERRA3500_FUEL_INJECTION_C6
- Service 22
DID 1198 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 6 SIERRA3500_FUEL_INJECTION_C6_DA11
- Service 22
DID 1198 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 7 SIERRA3500_FUEL_INJECTION_C7
- Service 22
DID 1199 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel injection, cylinder 8 SIERRA3500_FUEL_INJECTION_C8
- Service 22
DID 20B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2007 to 2019.
Fuel injection, cylinder 8 SIERRA3500_FUEL_INJECTION_C8_DA11
- Service 22
DID 20B3 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2020 to 2026.
Fuel remaining SIERRA3500_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 002F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2019.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2024. Supported for 2020 to 2021.
Fuel tank pressure SIERRA3500_FUEL_TANK_P
- Service 22
DID F432 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96 psi
- Unit
- psi
In testing for 2007 to 2019.
Fuel temperature SIERRA3500_FUEL_T
- Service 22
DID 3218 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2007 to 2019.
Fuel temperature SIERRA3500_FUEL_T_DA11
- Service 22
DID 3218 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Total fuel consumption rate SIERRA3500_TOTAL_FUEL_CONSUMPTION_RATE
- Service 22
DID 009D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2007 to 2019.
Total fuel consumption rate SIERRA3500_TOTAL_FUEL_CONSUMPTION_RATE_DA11
- Service 22
DID 009D - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2020 to 2026.
Movement
Desired idle speed SIERRA3500_DES_IDLE_SPD
- Service 22
DID 1192 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3187.5 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Torque converter clutch slip speed SIERRA3500_TC_SLIP_VSS
- Service 22
DID 1991 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Torque converter clutch slip speed SIERRA3500_TC_SLIP_VSS_DA18
- Service 22
DID 1991 - Module
DA18 → 2AF118 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Torque converter clutch slip speed SIERRA3500_TQ_CONV_CLU_SLIP_SPD
- Service 22
DID 1991 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Vehicle speed SIERRA3500_VSSConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID 000D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2007 to 2013, 2015 to 2018
Example reply from a 2014 GMC Sierra 3500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2014. In testing for 2007 to 2013, 2015 to 2018. Supported for 2021. Not supported for 2024.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024. Supported for 2014, 2020 to 2021.
Tires
Front left tire pressure SIERRA3500_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 5005 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Front left tire pressure SIERRA3500_TP_FL_DA40
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 5005 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Front left tire sensor ID SIERRA3500_TID_FL
- Service 22
DID 4005 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2007 to 2019.
Front left tire sensor ID SIERRA3500_TID_FL_DA40
- Service 22
DID 4005 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2020 to 2026.
Front right tire pressure SIERRA3500_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 5006 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Front right tire pressure SIERRA3500_TP_FR_DA40
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 5006 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Front right tire sensor ID SIERRA3500_TID_FR
- Service 22
DID 4006 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2007 to 2019.
Front right tire sensor ID SIERRA3500_TID_FR_DA40
- Service 22
DID 4006 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2020 to 2026.
Rear left tire pressure SIERRA3500_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 5008 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Rear left tire pressure SIERRA3500_TP_RL_DA40
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 5008 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Rear left tire sensor ID SIERRA3500_TID_RL
- Service 22
DID 4008 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2007 to 2019.
Rear left tire sensor ID SIERRA3500_TID_RL_DA40
- Service 22
DID 4008 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2020 to 2026.
Rear right tire pressure SIERRA3500_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 5007 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2007 to 2019.
Rear right tire pressure SIERRA3500_TP_RR_DA40
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 5007 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Rear right tire sensor ID SIERRA3500_TID_RR
- Service 22
DID 4007 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2007 to 2019.
Rear right tire sensor ID SIERRA3500_TID_RR_DA40
- Service 22
DID 4007 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2020 to 2026.
Transmission
Clutch slip, AT C1, ring SIERRA3500_CLU_SLIP_C1_RING
- Service 22
DID 2851 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Clutch slip, AT C3, ring SIERRA3500_CLU_SLIP_C3_RING
- Service 22
DID 19D4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Current gear SIERRA3500_CURRENT_GEAR
- Service 22
DID 1B30 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -3 to 252
- Unit
- Number
In testing for 2007 to 2019.
Current gear SIERRA3500_CURRENT_GEAR_7E0
- Service 22
DID 199A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Current gear, variant 2 SIERRA3500_CURRENT_GEAR_VAR_2
- Service 22
DID 199A - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Current gear, variant 3 SIERRA3500_CURRENT_GEAR_VAR_3
- Service 22
DID 3201 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2019.
Transmission fluid temperature, filtered SIERRA3500_TF_T_FLTED
- Service 22
DID 295A - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2019.
Transmission fluid temperature, filtered SIERRA3500_TF_T_FLTED_DA18
- Service 22
DID 295A - Module
DA18 → 2AF118 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission input shaft speed, 2 SIERRA3500_TRANS_ISS
- Service 22
DID 1941 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2007 to 2019.
Trips
Diesel particulate filter, average distance between regeneration events SIERRA3500_DPF_AVG_DIST_BETWEEN_REGENS
- Service 22
DID 20F7 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2020 to 2026.
Diesel particulate filter, distance since last regeneration SIERRA3500_DPF_DIST_SINCE_LAST_REGEN
- Service 22
DID 3039 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2020 to 2026.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2024.