Honda Prelude

Parameters

The Honda Prelude has 133 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery coolant temperature PRELUDE_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2026. In testing for 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery coolant temperature PRELUDE_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2026. In testing for 2025.

Battery module power PRELUDE_BATTERY_MODULE_POWERConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val×0.016
Range
-524.288 to 524.272 kW
Unit
kW

0x0000 = 0 → 0×0.016 = 0 kW

Confirmed for 2026. In testing for 2025.

High voltage battery cells, max state of charge PRELUDE_CELL_MAX_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2026. In testing for 2025.

High voltage battery cells, max state of charge PRELUDE_CELL_MIN_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2026. In testing for 2025.

High voltage battery module 1A temperature PRELUDE_HVB_MOD_1A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

High voltage battery module 3A temperature PRELUDE_HVB_MOD_3A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

High voltage battery total capacity PRELUDE_HVB_CAPConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

Confirmed for 2026. In testing for 2025.

High voltage battery total current PRELUDE_HVB_C_TOTALConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-100 to 200 A
Unit
A

Confirmed for 2026. In testing for 2025.

High voltage battery voltage PRELUDE_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

Confirmed for 2026. In testing for 2025.

HV battery cell max state of charge PRELUDE_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

0x10F4 = 4340 → 4340100 = 43.4 %

Confirmed for 2026. In testing for 2025.

HV battery current PRELUDE_HV_BATTERY_CURRENTConfirmed

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0104 = 260 → 260100 = 2.6 A

Confirmed for 2026. In testing for 2025.

HV battery fan 3 speed PRELUDE_HV_BATTERY_FAN_3_SPEED

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 288 to 295 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2025. Supported for 2026.

HV battery usable capacity PRELUDE_HV_BATTERY_USABLE_CAPACITYConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2026. In testing for 2025.

State of charge PRELUDE_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2026. In testing for 2025.

State of charge PRELUDE_STATE_OF_CHARGEConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x24 = 36 → 36 %

Confirmed for 2026. In testing for 2025.

Cells

Individual cell voltage A1 PRELUDE_CEL_V_A1Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A2 PRELUDE_CEL_V_A2Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A3 PRELUDE_CEL_V_A3Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A4 PRELUDE_CEL_V_A4Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A5 PRELUDE_CEL_V_A5Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A6 PRELUDE_CEL_V_A6Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A7 PRELUDE_CEL_V_A7Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A8 PRELUDE_CEL_V_A8Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A9 PRELUDE_CEL_V_A9Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A10 PRELUDE_CEL_V_A10Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A11 PRELUDE_CEL_V_A11Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A12 PRELUDE_CEL_V_A12Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A13 PRELUDE_CEL_V_A13Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A14 PRELUDE_CEL_V_A14Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A15 PRELUDE_CEL_V_A15Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A16 PRELUDE_CEL_V_A16Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A17 PRELUDE_CEL_V_A17Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A18 PRELUDE_CEL_V_A18Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A19 PRELUDE_CEL_V_A19Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A20 PRELUDE_CEL_V_A20Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A21 PRELUDE_CEL_V_A21Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A22 PRELUDE_CEL_V_A22Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A23 PRELUDE_CEL_V_A23Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A24 PRELUDE_CEL_V_A24Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A25 PRELUDE_CEL_V_A25Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A26 PRELUDE_CEL_V_A26Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A27 PRELUDE_CEL_V_A27Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A28 PRELUDE_CEL_V_A28Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A29 PRELUDE_CEL_V_A29Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A30 PRELUDE_CEL_V_A30Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A31 PRELUDE_CEL_V_A31Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A32 PRELUDE_CEL_V_A32Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A33 PRELUDE_CEL_V_A33Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A34 PRELUDE_CEL_V_A34Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A35 PRELUDE_CEL_V_A35Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A36 PRELUDE_CEL_V_A36Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A37 PRELUDE_CEL_V_A37Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A38 PRELUDE_CEL_V_A38Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A39 PRELUDE_CEL_V_A39Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A40 PRELUDE_CEL_V_A40Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A41 PRELUDE_CEL_V_A41Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A42 PRELUDE_CEL_V_A42Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A43 PRELUDE_CEL_V_A43Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A44 PRELUDE_CEL_V_A44Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A45 PRELUDE_CEL_V_A45Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A46 PRELUDE_CEL_V_A46Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A47 PRELUDE_CEL_V_A47Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A48 PRELUDE_CEL_V_A48Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A49 PRELUDE_CEL_V_A49Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A50 PRELUDE_CEL_V_A50Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A51 PRELUDE_CEL_V_A51Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A52 PRELUDE_CEL_V_A52Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A53 PRELUDE_CEL_V_A53Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A54 PRELUDE_CEL_V_A54Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A55 PRELUDE_CEL_V_A55Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A56 PRELUDE_CEL_V_A56Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A57 PRELUDE_CEL_V_A57Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A58 PRELUDE_CEL_V_A58Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A59 PRELUDE_CEL_V_A59Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A60 PRELUDE_CEL_V_A60Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A61 PRELUDE_CEL_V_A61Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A62 PRELUDE_CEL_V_A62Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A63 PRELUDE_CEL_V_A63Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A64 PRELUDE_CEL_V_A64Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A65 PRELUDE_CEL_V_A65Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A66 PRELUDE_CEL_V_A66Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A67 PRELUDE_CEL_V_A67Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A68 PRELUDE_CEL_V_A68Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A69 PRELUDE_CEL_V_A69Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A70 PRELUDE_CEL_V_A70Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A71 PRELUDE_CEL_V_A71Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A72 PRELUDE_CEL_V_A72Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A73 PRELUDE_CEL_V_A73Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A74 PRELUDE_CEL_V_A74Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A75 PRELUDE_CEL_V_A75Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A76 PRELUDE_CEL_V_A76Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A77 PRELUDE_CEL_V_A77Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A78 PRELUDE_CEL_V_A78Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A79 PRELUDE_CEL_V_A79Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A80 PRELUDE_CEL_V_A80Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A81 PRELUDE_CEL_V_A81Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A82 PRELUDE_CEL_V_A82Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A83 PRELUDE_CEL_V_A83Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Individual cell voltage A84 PRELUDE_CEL_V_A84Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2026. In testing for 2025.

Climate

Outside air temperature PRELUDE_AATConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °F
Unit
°F

Confirmed for 2026. In testing for 2025.

Clocks

Time since engine start PRELUDE_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2026. In testing for 2025.

ECU

Variable valve control PRELUDE_VTEC_CTRLConfirmed

  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1997 to 2001, 2025

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2026. In testing for 2025.

Electrical

Brake fluid pressure PRELUDE_BRK_FLD_PConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

Confirmed for 2026. In testing for 2025.

Brake pedal stroke PRELUDE_BRK_PED_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

Confirmed for 2026. In testing for 2025.

Brake pressure PRELUDE_BRK_PConfirmed

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

Confirmed for 2026. In testing for 2025.

Brake switch PRELUDE_BRK_SWConfirmed

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2026. In testing for 2025.

Master cylinder stroke PRELUDE_MSTR_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

Confirmed for 2026. In testing for 2025.

Slave cylinder stroke PRELUDE_SLV_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

Confirmed for 2026. In testing for 2025.

Engine

A/C clutch PRELUDE_AC_CLUTCHConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2026. In testing for 2025.

Air/gas ratio PRELUDE_AIRGAS_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2026. In testing for 2025.

Ambient air temperature, cabin PRELUDE_AAT_CABConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Ambient air temperature, outside PRELUDE_AAT_OUTConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Cabin air temperature PRELUDE_CABIN_AIR_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 200 to 207 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

0x1C = 28 → 28×1.8+32 = 82.4 °F

Confirmed for 2026. In testing for 2025.

DC-DC converter temperature PRELUDE_DC_DC_CONVERTER_TEMPERATUREConfirmed

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0000 = 0 → 010 = 0 °C

Confirmed for 2026. In testing for 2025.

Engine coolant temperature sensor 1 PRELUDE_ECT_1Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Engine coolant temperature sensor 2 PRELUDE_ECT_2Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Engine coolant temperature sensor 3 PRELUDE_ECT_3Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Engine coolant temperature sensor 4 PRELUDE_ECT_4Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026. In testing for 2025.

Fuel/air commanded equivalence ratio PRELUDE_FUELAIR_CARConfirmed

  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1997 to 2001, 2025

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2026. In testing for 2025.

Generator PRELUDE_GENERATORConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026. In testing for 2025.

Knock control PRELUDE_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1997 to 2001, 2025

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Raw value

Confirmed for 2026. In testing for 2025.

Misfire count #1 PRELUDE_MIS_1Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2026. In testing for 2025.

Misfire count #2 PRELUDE_MIS_2Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2026. In testing for 2025.

Misfire count #3 PRELUDE_MIS_3Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2026. In testing for 2025.

Misfire count #4 PRELUDE_MIS_4Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1997 to 2001, 2025

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2026. In testing for 2025.

Motor inverter, current PRELUDE_MOTOR_INVERTER_CURRENTConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2026. In testing for 2025.

Outside air temperature PRELUDE_OUTSIDE_AIR_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 208 to 215 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

0x00 = 0 → 0×1.8+32 = 32 °F

Confirmed for 2026. In testing for 2025.

Variable timing control duty PRELUDE_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1997 to 2001, 2025

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026. In testing for 2025.

Fuel

Fuel level PRELUDE_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 1997 to 2001, 2025

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

Confirmed for 2026. In testing for 2025.

Fuel/air commanded equivalence ratio PRELUDE_FUEL_AIR_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2026. In testing for 2025.

Movement

Generator motor speed PRELUDE_GENERATOR_MOTOR_SPEEDConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 1997 to 2001, 2025

Example reply from a 2026 Honda Prelude.

Bits 184 to 191 of the reply, 8 bits.

Formula
val×64
Range
0 to 16320 rpm
Unit
rpm

0x00 = 0 → 0×64 = 0 rpm

Confirmed for 2026. In testing for 2025.

Trips

Odometer PRELUDE_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1997 to 2001, 2025

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2026. In testing for 2025.

Odometer, variation 3 PRELUDE_ODO_V3Confirmed

  • Service 22DID 7022
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 1997 to 2001, 2025

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 200000 mi
Unit
mi

Confirmed for 2026. In testing for 2025.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.