Parameters
The Honda Prelude has 133 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery coolant temperature PRELUDE_BATTERY_COOLANT_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2026. In testing for 2025.
Battery module power PRELUDE_BATTERY_MODULE_POWERConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -524.288 to 524.272 kW
- Unit
- kW
0x0000 = 0 → = 0 kW
Confirmed for 2026. In testing for 2025.
High voltage battery cells, max state of charge PRELUDE_CELL_MAX_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2026. In testing for 2025.
High voltage battery cells, max state of charge PRELUDE_CELL_MIN_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2026. In testing for 2025.
High voltage battery module 1A temperature PRELUDE_HVB_MOD_1A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
High voltage battery module 3A temperature PRELUDE_HVB_MOD_3A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
High voltage battery total capacity PRELUDE_HVB_CAPConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
Confirmed for 2026. In testing for 2025.
High voltage battery total current PRELUDE_HVB_C_TOTALConfirmed
Pelican can show this parameter as the traction battery current.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 200 A
- Unit
- A
Confirmed for 2026. In testing for 2025.
High voltage battery voltage PRELUDE_HVB_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
Confirmed for 2026. In testing for 2025.
HV battery cell max state of charge PRELUDE_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
0x10F4 = 4340 → = 43.4 %
Confirmed for 2026. In testing for 2025.
HV battery current PRELUDE_HV_BATTERY_CURRENTConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
0x0104 = 260 → = 2.6 A
Confirmed for 2026. In testing for 2025.
HV battery fan 3 speed PRELUDE_HV_BATTERY_FAN_3_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2025. Supported for 2026.
HV battery usable capacity PRELUDE_HV_BATTERY_USABLE_CAPACITYConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2026. In testing for 2025.
State of charge PRELUDE_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2026. In testing for 2025.
State of charge PRELUDE_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x24 = 36 → 36 %
Confirmed for 2026. In testing for 2025.
Cells
Individual cell voltage A1 PRELUDE_CEL_V_A1Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A2 PRELUDE_CEL_V_A2Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A3 PRELUDE_CEL_V_A3Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A4 PRELUDE_CEL_V_A4Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A5 PRELUDE_CEL_V_A5Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A6 PRELUDE_CEL_V_A6Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A7 PRELUDE_CEL_V_A7Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A8 PRELUDE_CEL_V_A8Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A9 PRELUDE_CEL_V_A9Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A10 PRELUDE_CEL_V_A10Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A11 PRELUDE_CEL_V_A11Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A12 PRELUDE_CEL_V_A12Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A13 PRELUDE_CEL_V_A13Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A14 PRELUDE_CEL_V_A14Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A15 PRELUDE_CEL_V_A15Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A16 PRELUDE_CEL_V_A16Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A17 PRELUDE_CEL_V_A17Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A18 PRELUDE_CEL_V_A18Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A19 PRELUDE_CEL_V_A19Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A20 PRELUDE_CEL_V_A20Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A21 PRELUDE_CEL_V_A21Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A22 PRELUDE_CEL_V_A22Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A23 PRELUDE_CEL_V_A23Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A24 PRELUDE_CEL_V_A24Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A25 PRELUDE_CEL_V_A25Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A26 PRELUDE_CEL_V_A26Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A27 PRELUDE_CEL_V_A27Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A28 PRELUDE_CEL_V_A28Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A29 PRELUDE_CEL_V_A29Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A30 PRELUDE_CEL_V_A30Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A31 PRELUDE_CEL_V_A31Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A32 PRELUDE_CEL_V_A32Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A33 PRELUDE_CEL_V_A33Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A34 PRELUDE_CEL_V_A34Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A35 PRELUDE_CEL_V_A35Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A36 PRELUDE_CEL_V_A36Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A37 PRELUDE_CEL_V_A37Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A38 PRELUDE_CEL_V_A38Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A39 PRELUDE_CEL_V_A39Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A40 PRELUDE_CEL_V_A40Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A41 PRELUDE_CEL_V_A41Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A42 PRELUDE_CEL_V_A42Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A43 PRELUDE_CEL_V_A43Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A44 PRELUDE_CEL_V_A44Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A45 PRELUDE_CEL_V_A45Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A46 PRELUDE_CEL_V_A46Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A47 PRELUDE_CEL_V_A47Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A48 PRELUDE_CEL_V_A48Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A49 PRELUDE_CEL_V_A49Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A50 PRELUDE_CEL_V_A50Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A51 PRELUDE_CEL_V_A51Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A52 PRELUDE_CEL_V_A52Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A53 PRELUDE_CEL_V_A53Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A54 PRELUDE_CEL_V_A54Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A55 PRELUDE_CEL_V_A55Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A56 PRELUDE_CEL_V_A56Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A57 PRELUDE_CEL_V_A57Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A58 PRELUDE_CEL_V_A58Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A59 PRELUDE_CEL_V_A59Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A60 PRELUDE_CEL_V_A60Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A61 PRELUDE_CEL_V_A61Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A62 PRELUDE_CEL_V_A62Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A63 PRELUDE_CEL_V_A63Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A64 PRELUDE_CEL_V_A64Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A65 PRELUDE_CEL_V_A65Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A66 PRELUDE_CEL_V_A66Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A67 PRELUDE_CEL_V_A67Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A68 PRELUDE_CEL_V_A68Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A69 PRELUDE_CEL_V_A69Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A70 PRELUDE_CEL_V_A70Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A71 PRELUDE_CEL_V_A71Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A72 PRELUDE_CEL_V_A72Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A73 PRELUDE_CEL_V_A73Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A74 PRELUDE_CEL_V_A74Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A75 PRELUDE_CEL_V_A75Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A76 PRELUDE_CEL_V_A76Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A77 PRELUDE_CEL_V_A77Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A78 PRELUDE_CEL_V_A78Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A79 PRELUDE_CEL_V_A79Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A80 PRELUDE_CEL_V_A80Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A81 PRELUDE_CEL_V_A81Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A82 PRELUDE_CEL_V_A82Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A83 PRELUDE_CEL_V_A83Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Individual cell voltage A84 PRELUDE_CEL_V_A84Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2026. In testing for 2025.
Climate
Outside air temperature PRELUDE_AATConfirmed
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
Confirmed for 2026. In testing for 2025.
Clocks
Time since engine start PRELUDE_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2026. In testing for 2025.
ECU
Variable valve control PRELUDE_VTEC_CTRLConfirmed
- Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 1997 to 2001, 2025
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Electrical
Brake fluid pressure PRELUDE_BRK_FLD_PConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 1997 to 2001, 2025
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Raw value
Confirmed for 2026. In testing for 2025.
Brake pedal stroke PRELUDE_BRK_PED_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 1997 to 2001, 2025
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 mm
- Unit
- mm
Confirmed for 2026. In testing for 2025.
Brake pressure PRELUDE_BRK_PConfirmed
- Service 22
DID 4005 - Module
DA28 → 28 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2026. In testing for 2025.
Brake switch PRELUDE_BRK_SWConfirmed
- Service 22
DID 4004 - Module
DA28 → 28 - Every
1 s - Testing for 1997 to 2001, 2025
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2026. In testing for 2025.
Master cylinder stroke PRELUDE_MSTR_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 1997 to 2001, 2025
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
Confirmed for 2026. In testing for 2025.
Slave cylinder stroke PRELUDE_SLV_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 1997 to 2001, 2025
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 mm
- Unit
- mm
Confirmed for 2026. In testing for 2025.
Engine
A/C clutch PRELUDE_AC_CLUTCHConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2026. In testing for 2025.
Air/gas ratio PRELUDE_AIRGAS_RATIOConfirmed
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Ambient air temperature, cabin PRELUDE_AAT_CABConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Ambient air temperature, outside PRELUDE_AAT_OUTConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Cabin air temperature PRELUDE_CABIN_AIR_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
0x1C = 28 → = 82.4 °F
Confirmed for 2026. In testing for 2025.
DC-DC converter temperature PRELUDE_DC_DC_CONVERTER_TEMPERATUREConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0000 = 0 → = 0 °C
Confirmed for 2026. In testing for 2025.
Engine coolant temperature sensor 1 PRELUDE_ECT_1Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Engine coolant temperature sensor 2 PRELUDE_ECT_2Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Engine coolant temperature sensor 3 PRELUDE_ECT_3Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Engine coolant temperature sensor 4 PRELUDE_ECT_4Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2026. In testing for 2025.
Fuel/air commanded equivalence ratio PRELUDE_FUELAIR_CARConfirmed
- Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing for 1997 to 2001, 2025
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Generator PRELUDE_GENERATORConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2026. In testing for 2025.
Knock control PRELUDE_KNOCK_CONTROLConfirmed
ECU's determination of fuel quality.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1997 to 2001, 2025
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Raw value
Confirmed for 2026. In testing for 2025.
Misfire count #1 PRELUDE_MIS_1Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Misfire count #2 PRELUDE_MIS_2Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Misfire count #3 PRELUDE_MIS_3Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Misfire count #4 PRELUDE_MIS_4Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1997 to 2001, 2025
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Motor inverter, current PRELUDE_MOTOR_INVERTER_CURRENTConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2026. In testing for 2025.
Outside air temperature PRELUDE_OUTSIDE_AIR_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
0x00 = 0 → = 32 °F
Confirmed for 2026. In testing for 2025.
Variable timing control duty PRELUDE_VTC_DUTYConfirmed
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1997 to 2001, 2025
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2026. In testing for 2025.
Fuel
Fuel level PRELUDE_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 1997 to 2001, 2025
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2026. In testing for 2025.
Fuel/air commanded equivalence ratio PRELUDE_FUEL_AIR_RATIOConfirmed
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2026. In testing for 2025.
Movement
Generator motor speed PRELUDE_GENERATOR_MOTOR_SPEEDConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 1997 to 2001, 2025
Example reply from a 2026 Honda Prelude.
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 16320 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2026. In testing for 2025.
Trips
Odometer PRELUDE_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 1997 to 2001, 2025
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2026. In testing for 2025.
Odometer, variation 3 PRELUDE_ODO_V3Confirmed
- Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing for 1997 to 2001, 2025
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
Confirmed for 2026. In testing for 2025.