Hyundai i20

Parameters

The Hyundai i20 has 551 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level, volume I20_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x05 = 5 → 52 = 2.5 L

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery state of charge I20_BATTERY_SOCConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

12V battery temperature I20_12V_BAT_T

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2008 to 2026.

12V battery voltage I20_12V_BAT_V

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2008 to 2026.

Battery capacity, battery sensor I20_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2008 to 2026.

Battery charge flag, battery sensor I20_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Battery current I20_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2008 to 2026.

Battery current, battery sensor I20_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2008 to 2026.

Battery current, battery sensor I20_BAT_CURRENT_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 736 to 751 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val16
Range
-2048 to 2047.9375 A
Unit
A

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Battery current, battery sensor I20_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2008 to 2026.

Battery health aging flag, battery sensor I20_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Battery is in use to crank the engine flag, battery sensor I20_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Battery quiescent current flag, battery sensor I20_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Battery sensor invalid condition flag, battery sensor I20_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Battery state of charge, battery sensor I20_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Battery state of charge, battery sensor I20_BAT_ST_CHG_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 784 to 791 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Battery state of charge, battery sensor I20_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2026.

Battery state of function, battery sensor I20_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2008 to 2026.

Battery state of health, battery sensor I20_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Battery state of health, battery sensor I20_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2026.

Battery temperature I20_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2008 to 2026.

Battery temperature, battery sensor I20_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2026.

Battery temperature, battery sensor I20_BAT_T_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 768 to 783 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1953250000
Range
-255.9836 to 255.9758 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Battery temperature, battery sensor I20_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2008 to 2026.

Battery voltage I20_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2008 to 2026.

Battery voltage I20_BATTERY_VConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xB3 = 179 → 179×17.37255 = 12.193059 V

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Battery voltage after ignition I20_BATTERY_V_AFTER_IGNITIONConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xB4 = 180 → 180×17.37255 = 12.261176 V

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Battery voltage, battery sensor I20_BAT_V_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2008 to 2026.

Battery voltage, battery sensor I20_BAT_V_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 752 to 767 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×3265535
Range
0 to 32 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Battery voltage, battery sensor I20_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2008 to 2026.

Control module voltage I20_CONTROL_MODULE_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2021. Supported for 2023.

Control module voltage after ignition I20_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant temperature sensor voltage I20_COOLANT_T_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Dual-clutch transmission control module voltage I20_DUAL_CLU_TRANS_CTRL_V

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val13.6
Range
0 to 18.75 V
Unit
V

In testing for 2008 to 2026.

Gasoline particulate filter charge state I20_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Gasoline particulate filter inlet temperature sensor raw voltage I20_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2008 to 2026.

Gasoline particulate filter outlet temperature sensor raw voltage I20_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2008 to 2026.

IAT sensor voltage I20_IAT_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Manifold absolute pressure sensor voltage I20_MAP_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Relative accelerator pedal position voltage I20_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Response error from battery sensor flag, battery sensor I20_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Throttle position sensor voltage #1 I20_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Throttle position sensor voltage #2 I20_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Waste gate voltage I20_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2008 to 2026.

Wastegate position voltage I20_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2008 to 2026.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 2023.

Defogging? I20_DEFOG_SWConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Heated steering wheel I20_HEATED_WHEEL

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Heated steering wheel, alternate bit I20_HEATED_WHEEL_ALT

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Interior temperature, passenger legs vent I20_HVAC_IAT_PASSENGER_LEGS_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Interior temperature, passenger vent I20_HVAC_IAT_PASSENGER_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2021. Supported for 2023.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Brake booster pressure I20_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2008 to 2026.

Brake pedal I20_BRAKE_PEDAL

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Brake pedal I20_BRAKE_PEDAL_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Brake pressure I20_BRAKE_PConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

0x0000 = 0 → 086.7 = 0 %

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Brake switch I20_BRAKE_SW

  • Service 22DID B008
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Handbrake engaged? I20_HANDBRAKEConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Relative accelerator pedal position I20_APP_REL_TCM

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2023.

Steering angle I20_STEER_ANGLE_V2

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×10100
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Steering wheel angle I20_STEER_ANGLEConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x000B = 11 → 1110 = 1.1 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2023.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Doors

Front left door locked? I20_LOCK_FLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front left door open? I20_DOOR_FLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front right door locked? I20_LOCK_FRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front right door open? I20_DOOR_FRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Hood latched? I20_HOODConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear left door open? I20_DOOR_RLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 39 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear right door open? I20_DOOR_RRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Trunk open? I20_TRUNKConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021. Supported for 2023.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021. Supported for 2023.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2023.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2021. Supported for 2023.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Electrical

Cluster voltage I20_CLUSTER_VOLTAGEConfirmed

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0x00 = 0 → 012.8 = 0 V

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2021. Supported for 2023.

Adaptation value for lower stop of wastegate actuator I20_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2008 to 2026.

Air conditioning pressure I20_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×13.79
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2008 to 2026.

Air conditioning relay I20_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2021.

Automatic transmission fluid temperature I20_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission fluid temperature I20_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2021. Supported for 2023.

Barometric pressure I20_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Boost pressure I20_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2008 to 2026.

Boost pressure upstream I20_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2008 to 2026.

Boost pressure upstream, desired I20_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2008 to 2026.

Butane in liquefied petroleum gas I20_BUTANE_LPG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Calculated oil temperature I20_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2026.

Camshaft exhaust position, actual I20_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2008 to 2026.

Camshaft exhaust position, commanded I20_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2008 to 2026.

Camshaft intake position, actual I20_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2008 to 2026.

Camshaft intake position, commanded I20_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2008 to 2026.

Catalyst damaging misfires total all cylinders I20_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Catalyst damaging misfires total all cylinders I20_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 1 I20_CATALYST_DAMAGING_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Catalyst damaging misfires total, cylinder 1 I20_CATDMG_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 2 I20_CATALYST_DAMAGING_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Catalyst damaging misfires total, cylinder 2 I20_CATDMG_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 3 I20_CATALYST_DAMAGING_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Catalyst damaging misfires total, cylinder 3 I20_CATDMG_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 4 I20_CATALYST_DAMAGING_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Catalyst damaging misfires total, cylinder 4 I20_CATDMG_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 5 I20_CATDMG_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst damaging misfires total, cylinder 6 I20_CATDMG_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2021. Supported for 2023.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2021. Supported for 2023.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2023.

Commanded evaporative purge I20_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Commanded throttle actuator I20_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Coolant I20_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant fan PWM I20_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×15.2110000
Range
0 to 99.67 %
Unit
%

In testing for 2008 to 2026.

Coolant temperature I20_HVAC_COOLANT_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coverage driven length I20_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2026.

Crankshaft torque I20_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2008 to 2026.

Cylinder 1 injection time, 1st pulse I20_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 1 injection time, 2nd pulse I20_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 2 injection time, 1st pulse I20_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 2 injection time, 2nd pulse I20_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 3 injection time, 1st pulse I20_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 3 injection time, 2nd pulse I20_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 4 injection time, 1st pulse I20_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Cylinder 4 injection time, 2nd pulse I20_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Diesel particulate filter differential pressure I20_DPF_DIFF_P

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val×431.373100−100
Range
-100 to 1000
Unit
Raw value

In testing for 2008 to 2026.

Diesel particulate filter differential pressure I20_DPF_DIFF_P_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val×431.373100
Range
0 to 1100
Unit
Raw value

In testing for 2008 to 2026.

Diesel particulate filter regeneration count I20_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Diesel particulate filter regeneration state I20_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Diesel particulate filter successful regeneration count I20_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Direct injection time 1 I20_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Direct injection time 2 I20_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Direct injection time 3 I20_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Direct injection time 4 I20_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Direct injection time 5 I20_DI_TIME_5

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Direct injection time 6 I20_DI_TIME_6

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2008 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a I20_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2008 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b I20_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2008 to 2026.

Dual-clutch transmission fluid temperature 1 I20_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2026.

Dual-clutch transmission fluid temperature 2 I20_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2026.

Dual-clutch transmission line pressure, sensor c I20_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2008 to 2026.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021.

Emission relevant misfires total all cylinders I20_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total all cylinders I20_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Emission relevant misfires total, cylinder 1 I20_EMIS_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total, cylinder 1 I20_EMISSION_RELEVANT_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Emission relevant misfires total, cylinder 2 I20_EMIS_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total, cylinder 2 I20_EMISSION_RELEVANT_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Emission relevant misfires total, cylinder 3 I20_EMIS_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total, cylinder 3 I20_EMISSION_RELEVANT_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Emission relevant misfires total, cylinder 4 I20_EMIS_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total, cylinder 4 I20_EMISSION_RELEVANT_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Emission relevant misfires total, cylinder 5 I20_EMIS_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Emission relevant misfires total, cylinder 6 I20_EMIS_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Engine coolant temperature I20_ENGINE_COOLANT_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Engine oil temperature I20_ENGINE_OIL_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Engine oil temperature I20_EOTConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 272 to 279 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0xAC = 172 → 172×34−48 = 81 °C

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Engine oil temperature I20_EOT_7E0

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2008 to 2026.

Engine oil temperature I20_EOT_V2

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Engine RPM I20_ENGINE_RPM_TCM

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Engine run time, total I20_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2008 to 2026.

Engine running time total I20_ENG_RUNNING_TIME_TOT

  • Service 22DID E00E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393210 min
Unit
min

In testing for 2008 to 2026.

Engine, actual torque I20_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2352910000
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2008 to 2026.

Exhaust cam oil control valve duty I20_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Exhaust camshaft position I20_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2008 to 2026.

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021.

Exhaust gas temperature I20_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas temperature before gasoline particulate filter sensor 1 I20_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2008 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 I20_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2008 to 2026.

Exhaust gas volume flow I20_EXH_GAS_VOLUME_FLOW

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×7844910000
Range
0 to 2000
Unit
Raw value

In testing for 2008 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst I20_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2008 to 2026.

Exhaust temperature 2, upstream of DPF I20_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2008 to 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2021. Supported for 2023.

Gasoline direct injection time bank a, 1 I20_GDI_IT_A1Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank a, 2 I20_GDI_IT_A2Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank a, 3 I20_GDI_IT_A3Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank a, 4 I20_GDI_IT_A4Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank b, 1 I20_GDI_IT_B1Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank b, 2 I20_GDI_IT_B2Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank b, 3 I20_GDI_IT_B3Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Gasoline direct injection time bank b, 4 I20_GDI_IT_B4Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Idle control mode I20_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Ignition retard due to knock control 1 I20_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Ignition retard due to knock control 2 I20_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Ignition retard due to knock control 3 I20_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Ignition retard due to knock control 4 I20_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Injection duration cylinder 1 I20_INJ_DUR_1Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Injection duration cylinder 2 I20_INJ_DUR_2Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Injection duration cylinder 3 I20_INJ_DUR_3Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Injection duration cylinder 4 I20_INJ_DUR_4Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Injection impulse 1, cylinder 1 I20_INJ_IMPULSE_1_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 1, cylinder 2 I20_INJ_IMPULSE_1_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 1, cylinder 3 I20_INJ_IMPULSE_1_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 1, cylinder 4 I20_INJ_IMPULSE_1_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 2, cylinder 1 I20_INJ_IMPULSE_2_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 2, cylinder 2 I20_INJ_IMPULSE_2_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 2, cylinder 3 I20_INJ_IMPULSE_2_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 2, cylinder 4 I20_INJ_IMPULSE_2_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 3, cylinder 1 I20_INJ_IMPULSE_3_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 3, cylinder 2 I20_INJ_IMPULSE_3_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 3, cylinder 3 I20_INJ_IMPULSE_3_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2008 to 2026.

Injection impulse 3, cylinder 4 I20_INJ_IMPULSE_3_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2008 to 2026.

Injector correction factor 1 I20_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2008 to 2026.

Injector correction factor 2 I20_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2008 to 2026.

Injector correction factor 3 I20_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2008 to 2026.

Injector correction factor 4 I20_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2008 to 2026.

Intake air temperature I20_EITConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 264 to 271 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x64 = 100 → 100×34−48 = 27 °C

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Intake air temperature I20_INTAKE_AIR_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Intake cam oil control valve duty I20_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Intake camshaft position I20_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2008 to 2026.

Intake camshaft position actual I20_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Intake camshaft position commanded I20_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Intake manifold absolute pressure I20_INTAKE_MANIFOLD_ABSOLUTE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val256
Range
0 to 255 kPa
Unit
kPa

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Inverter temperature I20_HVAC_INVERTER_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock detected I20_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock detected I20_KNOCK_DETECTED_7E0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock learn, cylinder 1 I20_KNOCK_LEARN_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock learn, cylinder 2 I20_KNOCK_LEARN_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock learn, cylinder 3 I20_KNOCK_LEARN_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock learn, cylinder 4 I20_KNOCK_LEARN_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock retard cylinder #1 I20_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder #2 I20_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder #3 I20_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder #4 I20_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder 1 I20_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 1, alternate I20_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder 1, alternate I20_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 2 I20_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 2, alternate I20_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder 2, alternate I20_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 3 I20_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 3, alternate I20_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder 3, alternate I20_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 4 I20_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2026.

Knock retard cylinder 4, alternate I20_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Knock retard cylinder 4, alternate I20_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2008 to 2026.

Knock retard, cylinder 1 I20_KNOCK_RETARD_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock retard, cylinder 2 I20_KNOCK_RETARD_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock retard, cylinder 3 I20_KNOCK_RETARD_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Knock retard, cylinder 4 I20_KNOCK_RETARD_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Liquefied petroleum gas low side temperature I20_LPG_LOW_SIDE_T

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2008 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019.

Main injection volume I20_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Mass air flow rate I20_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2008 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running I20_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2008 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop I20_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2008 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running I20_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2008 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop I20_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2008 to 2026.

Misfires current total I20_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 1 I20_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 2 I20_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 3 I20_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 4 I20_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 5 I20_MIS_CURRENT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires current, cylinder 6 I20_MIS_CURRENT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Misfires harmful for catalyst, cylinder 1 I20_MIS_HARMFUL_CAT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires harmful for catalyst, cylinder 2 I20_MIS_HARMFUL_CAT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires harmful for catalyst, cylinder 3 I20_MIS_HARMFUL_CAT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires harmful for catalyst, cylinder 4 I20_MIS_HARMFUL_CAT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires, current, cylinder 1 I20_MISFIRES_C1_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Misfires, current, cylinder 2 I20_MISFIRES_C2_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Misfires, current, cylinder 3 I20_MISFIRES_C3_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Misfires, current, cylinder 4 I20_MISFIRES_C4_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Misfires, cylinder 1 I20_MIS_1_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires, cylinder 2 I20_MIS_2_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires, cylinder 3 I20_MIS_3_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Misfires, cylinder 4 I20_MIS_4_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Motor-driven power steering current I20_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x02 = 2 → 2 A

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Oil pump PWM I20_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2008 to 2026.

Output speed I20_OUTPUT_SPEED

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Overheat protection, active I20_OVERHEAT_PROTECTION

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2026.

Oxygen sensor 1 bank 1 I20_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Oxygen sensor 2 bank 1 I20_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Parking sensor rear center left level I20_PARKING_SENS_REAR

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Parking sensor rear center right level I20_PARKING_SENS_REAR_CENTER

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Pilot injection volume I20_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Post injection volume I20_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rail pressure control valve I20_RAIL_P_CTRL_VLV

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
val×2051
Range
0 to 0.3921
Unit
Off or on

In testing for 2008 to 2026.

Regeneration demand counter by soot load I20_REGEN_DEMAND_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Requested torque I20_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Requested torque limitation from traction control I20_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021.

Successful regeneration state I20_SUCCESSFUL_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 424 to 431 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2008 to 2026.

Throttle position #1 I20_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Throttle position #2 I20_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Timing advance #1 I20_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Timing advance #2 I20_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Timing advance #3 I20_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Timing advance #4 I20_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip I20_TORQUE_CONVERTER_SLIP

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip I20_TORQUE_CONVERTER_SLIP_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip I20_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2008 to 2026.

Torque, actual I20_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2008 to 2026.

Total sulfur mass I20_TOT_SULFUR_MASS

  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000
Range
0 to 9999
Unit
Raw value

In testing for 2008 to 2026.

Transmission fluid temperature I20_ATF_T_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2026.

Turbine speed I20_TURBINE_SPEED

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Turbo boost pressure I20_TB_PRES

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543 kPa
Unit
kPa

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Turbo boost pressure I20_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2008 to 2026.

Turbo boost pressure I20_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2008 to 2026.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2021.

Variable valve timing temperature I20_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Waste gate duty I20_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2008 to 2026.

Waste gate duty I20_WG_DUTY

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Waste gate position I20_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2008 to 2026.

Waste gate position I20_WG_POS

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×0.00610352
Range
-200 to 199.99 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Waste gate set point I20_WG_SP

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val×0.00610352
Range
-200 to 199.99 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Waste gate target I20_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2008 to 2026.

Waste gate voltage I20_WG_V

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Wastegate control PWM, wastegate actuator I20_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2008 to 2026.

Wastegate position target, wastegate actuator I20_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2008 to 2026.

Wastegate position, wastegate actuator I20_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2008 to 2026.

Wide open throttle I20_WIDE_OPEN_THROTTLEConfirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Internal

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2021.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2021.

Misfires

Emission-relevant misfires, cylinder #1 I20_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Emission-relevant misfires, cylinder #2 I20_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Emission-relevant misfires, cylinder #3 I20_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Emission-relevant misfires, cylinder #4 I20_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires harmful for catalyst cylinder 1 I20_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires harmful for catalyst cylinder 2 I20_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires harmful for catalyst cylinder 3 I20_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires harmful for catalyst cylinder 4 I20_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires total counter, all cylinders I20_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires total counter, cylinder #1 I20_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires total counter, cylinder #2 I20_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires total counter, cylinder #3 I20_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires total counter, cylinder #4 I20_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires, cylinder 1 I20_MIS_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires, cylinder 2 I20_MIS_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires, cylinder 3 I20_MIS_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Misfires, cylinder 4 I20_MIS_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2023.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2021.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2021.

Unknown

Engine status byte I20_E004_BYTE0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Fuel

Cycle fuel consumption I20_CYCLE_FUEL_CONS

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
val×8.478100
Range
0 to 21.6189
Unit
Raw value

In testing for 2008 to 2026.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2021.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021.

Fuel consumption since last DPF regeneration I20_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2008 to 2026.

Fuel cut I20_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Fuel cut I20_FUEL_CUT_7E0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Fuel injection timing #1 I20_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection timing #2 I20_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection timing #3 I20_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection timing #4 I20_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Fuel level input I20_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2008 to 2026.

Fuel level, volume I20_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x05 = 5 → 52 = 2.5 L

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Fuel pressure I20_FUEL_P

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2008 to 2026.

Fuel pressure deviation I20_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2008 to 2026.

Fuel pressure set point I20_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2008 to 2026.

Fuel pressure set point deviation I20_FUEL_P_SET_POINT_DEV

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306610000
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2008 to 2026.

Fuel pressure, actual I20_FUEL_P_ACT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2008 to 2026.

Fuel pressure, set point I20_FUEL_P_SET_POINT_7E0

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2008 to 2026.

Fuel rail low pressure I20_FUEL_RAIL_LOW_P

  • Service 22DID E006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2008 to 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Fuel temperature I20_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×784310000−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2008 to 2026.

Liquefied petroleum gas electrical fuel pump PWM I20_LPG_ELECTRICAL_FUEL

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Liquefied petroleum gas pressure in fuel rail, average I20_LPG_P_FUEL_RAIL_AVG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2008 to 2026.

Short term fuel % trim, bank 1 I20_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Short term fuel % trim, bank 1 idle I20_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021.

Lights

Brake light I20_BRAKE_LIGHTConfirmed

  • Service 22DID BC06
  • Module770 → 778
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Defog light I20_DEFOG_LIGHTConfirmed

  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Exterior lights state code I20_LIGHTS_CODE

  • Service 22DID BC10
  • Module770 → 778
  • Every5 s
  • Testing

Bits 32 to 35 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2008 to 2026.

Hazard switch I20_HAZARD_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Headlight high beam I20_HL_HIGHConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Headlight low beam I20_HL_LOWConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Headlight switch I20_HL_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Left turn signal on? I20_TURN_LConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Right turn signal on? I20_TURN_RConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Movement

Actual acceleration I20_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2008 to 2026.

Commanded engine idle RPM I20_COMMANDED_ENGINE_IDLE_RPM

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant fan high speed I20_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant fan high speed, 1.8 I20_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant fan low speed I20_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Coolant fan low speed, 1.8 I20_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Dual-clutch transmission engine RPM I20_DUAL_CLU_TRANS_RPM

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2008 to 2026.

Dual-clutch transmission vehicle speed I20_DUAL_CLU_TRANS_VSS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2026.

Engine coolant fan high speed, on/off I20_ENG_CLT_FAN_HIGH_SPD_ON_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Engine coolant fan low speed I20_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Engine RPM I20_ENGINE_RPM

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Engine RPM I20_RPM_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Front left wheel speed I20_FL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Front left wheel speed I20_TIRE_FL_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front left wheel speed I20_TIRE_FL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Front right wheel speed I20_FR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Front right wheel speed I20_TIRE_FR_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front right wheel speed I20_TIRE_FR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Output speed I20_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2026.

Output speed I20_OUTPUT_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear left wheel speed I20_RL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear left wheel speed I20_TIRE_RL_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear left wheel speed I20_TIRE_RL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear right wheel speed I20_RR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear right wheel speed I20_TIRE_RR_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear right wheel speed I20_TIRE_RR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Relative accelerator pedal position I20_REL_APP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Relative accelerator pedal position I20_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Turbine speed I20_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2026.

Turbine speed I20_TURBINE_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed I20_VEHICLE_SPEED

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed I20_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Vehicle speed I20_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Vehicle speed, average I20_VSS_AVGConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Vehicle speed, v2 I20_VSS_V2

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle traction control switch, raw I20_TC_SWITCHConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2021. Supported for 2015, 2018 to 2019, 2023.

Seatbelts

Driver seatbelt latched? I20_BELT_DRIVConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Passenger seatbelt latched? I20_BELT_PASSConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear left seatbelt latched? I20_BELT_RLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear middle seatbelt latched? I20_BELT_RMConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 52 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear right seatbelt latched? I20_BELT_RRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Tires

Front left tire pressure I20_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0x90 = 144 → 1445 = 28.8 psi

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front left wheel speed I20_FL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Front right tire pressure I20_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0x02 = 2 → 25 = 0.4 psi

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Front right wheel speed I20_FR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear left tire pressure I20_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2008 to 2020, 2022 to 2026

Bits 96 to 103 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2008 to 2020, 2022 to 2026. Supported for 2021.

Rear left wheel speed I20_RL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Rear right tire pressure I20_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 128 to 135 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0x01 = 1 → 15 = 0.2 psi

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Rear right wheel speed I20_RR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Tire sensor 1 ID I20_TID_1

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2008 to 2026.

Tire sensor 2 ID I20_TID_2

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2008 to 2026.

Tire sensor 3 ID I20_TID_3

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2008 to 2026.

Tire sensor 4 ID I20_TID_4

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2008 to 2026.

Transmission

Clutch #1 temperature I20_CLUTCH_1_TConfirmed

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 232 to 247 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

0x0045 = 69 → 69×2−40 = 98 °C

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Clutch #2 temperature I20_CLUTCH_2_TConfirmed

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 248 to 263 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

0x0043 = 67 → 67×2−40 = 94 °C

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Commanded gear I20_COMMANDED_GEAR

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Commanded gear I20_COMMANDED_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Current gear I20_CURRENT_GEAR

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Current gear I20_CURRENT_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Current gear I20_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Current gear I20_GEAR_CURConfirmed

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

0b0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Dual-clutch transmission absolute pedal position d I20_DUAL_CLU_TRANS_ABS_D

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Dual-clutch transmission clutch 1 slip I20_DUAL_CLU_TRANS_CLU_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2008 to 2026.

Dual-clutch transmission clutch 1 temperature I20_DUAL_CLU_TRANS_CLU_1_T

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 °C
Unit
°C

In testing for 2008 to 2026.

Dual-clutch transmission clutch 2 slip I20_DUAL_CLU_TRANS_CLU_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2008 to 2026.

Dual-clutch transmission even shaft, gear engaged I20_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Dual-clutch transmission gear ratio I20_DUAL_CLU_TRANS_GEAR

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2008 to 2026.

Dual-clutch transmission input shaft 1 I20_DUAL_CLU_TRANS_INPUT_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2008 to 2026.

Dual-clutch transmission input shaft 2 I20_DUAL_CLU_TRANS_INPUT_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2008 to 2026.

Dual-clutch transmission odd shaft, gear engaged I20_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Dual-clutch transmission throttle position I20_DUAL_CLU_TRANS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

Gear I20_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2026.

Gear selector I20_GEAR

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Next gear I20_GEAR_NXTConfirmed

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

0b0000 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Reverse gear selected I20_GEAR_RConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Transmission fluid temperature I20_ATF_TEMP

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Trips

Diesel particulate filter odometer at last regeneration I20_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2026.

Distance since last DPF regeneration I20_DIST_SINCE_DPF_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 50000 km
Unit
km

In testing for 2008 to 2026.

Distance since last DPF regeneration I20_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Distance since last gasoline particulate filter regeneration I20_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2026.

Odometer I20_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Odometer I20_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2026.

Odometer at last DPF regeneration I20_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2020, 2022 to 2026. Not supported for 2021.

Odometer at last gasoline particulate filter regeneration I20_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2026.

Odometer, imperial I20_ODO_MIConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

0x00580D = 22541 → 22,541 mi

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Odometer, metric I20_ODO_KMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2008 to 2020, 2022 to 2026

Example reply from a 2021 Hyundai i20.

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x015EB5 = 89781 → 89,781 km

Confirmed for 2021. In testing for 2008 to 2020, 2022 to 2026.

Sensor 1 odometer event 1 I20_SENS_1_ODO_EVT_1

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 1 odometer event 2 I20_SENS_1_ODO_EVT_2

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 1 odometer event 3 I20_SENS_1_ODO_EVT_3

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 2 odometer event 1 I20_SENS_2_ODO_EVT_1

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 2 odometer event 2 I20_SENS_2_ODO_EVT_2

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 2 odometer event 3 I20_SENS_2_ODO_EVT_3

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 3 odometer event 1 I20_SENS_3_ODO_EVT_1

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 3 odometer event 2 I20_SENS_3_ODO_EVT_2

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 3 odometer event 3 I20_SENS_3_ODO_EVT_3

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 4 odometer event 1 I20_SENS_4_ODO_EVT_1

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 4 odometer event 2 I20_SENS_4_ODO_EVT_2

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Sensor 4 odometer event 3 I20_SENS_4_ODO_EVT_3

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2008 to 2026.

Vehicle total distance I20_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2008 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.