Lexus GX 460

Parameters

The Lexus GX 460 has 582 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage GX_12V_V_700Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 79 V
Unit
V

0x26FC = 9980 → 9980×12.20710000 = 12.182586 V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage GX_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

1st turbocharger outlet pressure, control valve GX_1ST_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

2nd turbocharger outlet pressure GX_2ND_TRUBOCHARGER_OUTLET_P

  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

2nd turbocharger outlet pressure, control valve GX_2ND_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Aux. battery capacity after IG OFF GX_AUX_BAT_CAP_AFTER_IG_OFF

  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Aux. battery capacity after IG ON GX_AUX_BAT_CAP_AFTER_IG_ON

  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery current GX_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery current GX_BAT_CURRENT_700

  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4912850−125
Range
-125 to 124.9 A
Unit
A

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery status of full charge GX_BAT_STAT_FULL_CHG

  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2552
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery temperature GX_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery temperature GX_BAT_T_700

  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery temperature GX_BAT_T_700_2

  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery voltage GX_12V_V_700Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 79 V
Unit
V

0x26FC = 9980 → 9980×12.20710000 = 12.182586 V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Battery voltage GX_BAT_V

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery voltage GX_BATTERY_VOLTAGE_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Charge contactor current GX_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Charging integrated current of aux. battery GX_CHG_INTEGRATED

  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Dark current of battery GX_DARK_CURRENT_BAT

  • Service 22DID 15E7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Discharging integrated current of aux. battery GX_DISCHARGING

  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Distance since last battery cable disconnection GX_DIST_SINCE_BAT_DISCConfirmed

  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0016 = 22 → 22 km

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Initial engine battery voltage lower limit GX_INITIAL_ENG_BAT_V_LO

  • Service 22DID 15F6
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Main connector solenoid current GX_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Main relay a, solenoid current GX_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Main relay r solenoid current GX_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Output speed sensor voltage GX_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Regen cooperation GX_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Regenerative operation GX_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Regenerative request GX_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Relay control solenoid current GX_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Service contactor solenoid current GX_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Sleep time of battery sensor GX_SLEEP_TIME_BATSENS

  • Service 22DID 15F0
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Turbine speed sensor voltage GX_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Voltage of battery sensor GX_V_BATSENS

  • Service 22DID 15EE
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333310922500
Range
0 to 79.9979 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Brakes

Master cylinder sensor temperature GX_MASTER_CYL_TEMPConfirmed

  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−80
Range
-20 to 100 °C
Unit
°C

0x47 = 71 → 71−80 = -9 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Parking brake actuator status GX_EPBConfirmed

  • Service 22DID 1045
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → APPLIED

States
Raw valueStateMeaning
0APPLIEDApplied

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Climate

A/C compressor pressure GX_IA_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor pressure sensor voltage GX_IA_AC_P_SENS_V

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor, state GX_IA_AC_STATE

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Adjusted ambient temperature GX_ADJUSTED_AMBIENT_T

  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×81.6255−30.8
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper actual pulse GX_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper target pulse GX_AIR_INLET_DAMPER_TARGET_PULSE

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air mix servo, actual pulse, driver GX_AIR_MIX_SERVO_ACT_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo pulse, driver GX_AIR_OUTLET_SERVO_PULSE_D

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo, actual pulse, driver GX_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature GX_AMBIENT_T_700Confirmed

  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x1E = 30 → 30−40 = -10 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Ambient temperature, alternate GX_IA_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature, climate GX_AAT_7C4_V2Confirmed

  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

0x02F3 = 755 → 755100 = 7.55 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Blower level GX_BLOWERConfirmed

  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Blower motor speed level GX_BLOWER_MOTOR_SPEED_LEVEL

  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cabin temperature GX_CABIN_T_V2Confirmed

  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

0x038F = 911 → 911100 = 9.11 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Climate set point code GX_HVAC_SET_RAWConfirmed

  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x28 = 40 → 40

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Communication with air conditioner GX_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Communication with HV GX_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Communication with valvematic GX_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporator fin thermistor GX_EVAP_FIN_THERMISTOR

  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−29.7
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Set temperature, driver side GX_T_DRIVER

  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Solar sensor, driver side GX_SOLAR_DRIVER

  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Control

A/C compressor GX_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator pedal GX_ACCEL_PEDALConfirmed

  • Service 22DID 1059
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val1.42−28.873
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Accelerator sensor 1 voltage GX_ACCEL_SENS__NO_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator sensor 2 voltage GX_ACCEL_SENS__NO_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Anti-lock brake warning GX_ABS_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Brake pedal stroke GX_BRAKE_STROKE

  • Service 22DID 104C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mm
Unit
mm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Brake warning GX_BRAKE_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Buzzer GX_BUZZER

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Check engine GX_CHECK_ENGINE

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Communication with brake GX_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cruise control live brake cancel GX_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electrical load signal 1 GX_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electrical load signal 2 GX_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electronically controlled brake warning GX_ECB_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ignition trigger count GX_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Key remind sound GX_KEY_REMIND_SOUND

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Neutral position GX_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Parking brake GX_PARKING_BRAKEConfirmed

  • Service 21PID 62
  • Module7D0 → 7D8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Parking brake GX_PARKING_BRAKE_7B0

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Power mode pattern switch GX_PATTERN_SWITCH_PWR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Power steering GX_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Shift SW status, d range GX_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Shift SW status, n range GX_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Shift SW status, p range GX_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Shift SW status, r range GX_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Slip indicator GX_SLIP_INDICATOR

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Sports mode selection GX_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Sports shift down GX_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Sports shift up GX_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Starter control GX_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Starter signal GX_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Steering angle GX_STEERING_ANGLEConfirmed

  • Service 22DID 1004
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1.5
Range
-410 to 410 °
Unit
°

0x0000 = 0 → 0×1.5 = 0 °

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Steering wheel angle GX_STEER_ANGLEConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276.7 °
Unit
°

0x7F01 = 32513 → 3251310−3276.8 = -25.5 °

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Tail cancel GX_TAIL_CANCEL

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

TC GX_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Traction brake control GX_TRC_BRAKE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Traction control GX_TRC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Traction engine control GX_TRC_ENGINE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Zero point of deceleration GX_ZP_DEC

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Zero point of deceleration 2 GX_ZP_DEC2

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Zero point of yaw rate GX_ZP_YAW_RATE

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cruise control

Cruise control speed GX_CC_S

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Details

Inspection mode GX_INSPECTION_MODE

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

DTCs

2nd air monitor avail GX_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

2nd air monitor incomplete GX_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C monitor avail GX_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C monitor incomplete GX_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor heater monitor available GX_O2S_A_FS__HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor heater monitor incomplete GX_O2S_A_FS__HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor monitor available GX_O2S_A_FS__MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor monitor incomplete GX_O2S_A_FS__MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst monitor avail GX_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst monitor incomplete GX_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Complete parts monitor_avail GX_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023. Supported for 2024 to 2025.

EGR/VVT monitor avail GX_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

EGR/VVT monitor incomplete GX_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

EVAP monitor avail GX_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

EVAP monitor_icmpl GX_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel system monitor_avail GX_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Heated catalyst monitor avail GX_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Heated catalyst monitor incomplete GX_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

MIL GX_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

MIL ON run distance GX_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire monitor avail GX_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Number of DTCs GX_IA_DTC_CNTD

  • Service 22DID 0202
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Number of emission DTC GX_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Running time from MIL ON GX_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electrical

Battery voltage GX_BATTERY_VOLTAGEConfirmed

  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 20 V
Unit
V

0x00 = 0 → 010 = 0 V

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Engine

A/F heater duty bank 1 sensor 1 GX_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/F ratio learn value high, bank 1 GX_AF_LEARN_HIGH_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x97 = 151 → 151×100255−50 = 9.215686 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/F ratio learn value idle, bank 1 GX_AF_LEARN_IDLE_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/F ratio learn value low, bank 1 GX_AF_LEARN_LOW_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/F ratio learn value mid.1, bank 1 GX_AF_LEARN_MID1_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x8A = 138 → 138×100255−50 = 4.117647 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/F ratio learn value mid.2, bank 1 GX_AF_LEARN_MID2_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0xA3 = 163 → 163×100255−50 = 13.921569 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/F ratio learned high, bank 1 GX_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

A/F ratio learned idle, bank 1 GX_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

A/F ratio learned low, bank 1 GX_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

A/F ratio learned mid 1, bank 1 GX_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

A/F ratio learned mid 2, bank 1 GX_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

A/F test results 1, incomplete GX_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accessory relay on GX_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accumulator open GX_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Acoustic control induction system vacuum switching valve on GX_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Actual engine percent torque GX_IA_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Actual engine torque GX_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Actuator power supply on GX_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

AF lambda B1S1 GX_AF_LAMBDA_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air conditioning compressor GX_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air mix servo target pulse, driver GX_AIR_MIX_SERVO_TARG_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor current, bank 1 sensor 1 GX_AFS_CURRENT_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 127.99 mA
Unit
mA

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air-fuel sensor voltage, bank 1 sensor 1 GX_AFS_VOLTAGE_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Alt voltage - active test GX_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Alt voltage - non active test GX_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Alternator output duty GX_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Alternator output duty cycle GX_ALT_DUTY_CYCLEConfirmed

  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val164
Range
0 to 399 %
Unit
%

0x0400 = 1024 → 1024164 = 6.243902 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Ambient air temperature GX_AAT_7C4

  • Service 21PID 22
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−23.3
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature GX_AMBIENT_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

APP sensor 1 voltage GX_IA_APP1_V

  • Service 22DID 0914
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

APP sensor 2 voltage GX_IA_APP2_V

  • Service 22DID 0915
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Atmosphere pressure GX_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Automatic transmission fluid thermal degradation estimate GX_ATF_THERMAL_DEGRAD_ESTConfirmed

  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x03B1 = 945 → 945

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Cabin temperature GX_CABIN_T

  • Service 21PID 21
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×63.75255−6.5
Range
-6.5 to 57.25 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Calculated load_7e0 GX_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature GX_IA_CAT_TEMP

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature B1S1 GX_CATALYST_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature B1S2 GX_CATALYST_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature bank 1 sensor 2 GX_CAT_T_B1S2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature bank 2 sensor 1 GX_CAT_T_BANK_2_SENS_1Confirmed

  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

0x02A8 = 680 → 680×950−40 = 82.4 °F

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Catalyst temperature bank 2 sensor 2 GX_CAT_T_BANK_2_SENS_2Confirmed

  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

0x01EF = 495 → 495×950−40 = 49.1 °F

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Check mode on GX_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Closed throttle position switch on GX_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Codes, include history GX_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Continuously variable transmission learning complete GX_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Continuously variable transmission oil pressure GX_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Coolant temp GX_COOLANT_TEMP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Coolant temperature GX_COOLANT_T

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Coolant water route switching valve 1, closed? GX_COOLANT_VALVE_1_CLOSE

  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Coolant water route switching valve 2, closed? GX_COOLANT_VALVE_2_CLOSE

  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cooling fan duty ratio GX_COOLING_FAN_DUTY_RATIO

  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×127.5255
Range
0 to 127.5 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cruise control on GX_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder 1 injection volume GX_CYL_1_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder 2 injection volume GX_CYL_2_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder 3 injection volume GX_CYL_3_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder 4 injection volume GX_CYL_4_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder number GX_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Destination GX_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Dist battery cable disconnect GX_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Distance since DTC clear GX_IA_DIST_DTC_CLR

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Distance with MIL GX_IA_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electric fan motor on GX_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electric thermostat duty ratio GX_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electric water pump GX_ELECTRIC_WATER_PUMP

  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electric water pump RPM GX_EWP_RPM

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Electric water pump target speed GX_EWP_TARGET_VSS

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Engine coolant temperature GX_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature, at ignition GX_ECT_IGNConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x36 = 54 → 54×62.5100−40 = -6.25 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine coolant temperature, initial GX_ECT_INITConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x36 = 54 → 54×62.5100−40 = -6.25 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine independent GX_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine independent control GX_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine load GX_IA_ENG_LOAD_PCT

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine load, actual GX_IA_ENG_LOAD_ACT

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine oil pressure GX_EOPConfirmed

  • Service 22DID 1074
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10128
Range
0 to 1000 kPa
Unit
kPa

0x0000 = 0 → 0×10128 = 0 kPa

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Engine oil pressure GX_IA_EOP

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine oil pressure control valve GX_EOP_CONTROL_VALVE

  • Service 22DID 2848
  • Module700 → 708
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0762939
Range
0 to 4999.9207 mA
Unit
mA

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Engine oil temperature GX_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 107B
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 192 to 199 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Engine oil temperature GX_EOT_V1Confirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Engine oil temperature GX_EOT_V2Confirmed

  • Service 22DID 1F5C
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x22 = 34 → 34−40 = -6 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Engine oil temperature GX_IA_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615.35 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine reference torque GX_IA_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine run time GX_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine run time GX_IA_RUN_TIME

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine run time, up to 255 sec. only GX_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed GX_IA_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine stall control FB flow GX_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

EVAP purge duty GX_EVAP_PURGE_DUTY

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge GX_IA_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge duty GX_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge flow GX_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge vacuum switching valve on GX_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporator target temp GX_EVAP_TARG_T

  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas recirculation step position GX_EGR_STEP_POSITION

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas recirculation temperature GX_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust gas recirculation valve step GX_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust VVT change angle, bank 1 GX_EXHAUST_VVT_ANGLE_B1Confirmed

  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Exhaust VVT hold learn value, bank 1 GX_EXHAUST_VVT_HOLD_LEARN_B1Confirmed

  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535
Range
0 to 399.9 %
Unit
%

0x1E7B = 7803 → 7803×399.965535 = 47.614553 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Exhaust VVT oil control valve control duty GX_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed

  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×40065535
Range
0 to 400 %
Unit
%

0x0000 = 0 → 0×40065535 = 0 %

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Exhaust VVT target angle B1 GX_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed

  • Service 22DID 1071
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Exhaust VVT timing most over-advanced learn value, bank 1 GX_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed

  • Service 22DID 108F
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

0x2EB9 = 11961 → 11961×639.9965535 = 116.806598 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel cut for engine stop request GX_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel cut TAU on GX_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel filter temperature GX_FFT

  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel trim, long term GX_IA_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel trim, short term GX_IA_STFT

Pelican can show this parameter as the short term fuel trim.

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

G sensor calibration, complete GX_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

G sensor learning value GX_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Generator field coil control duty GX_IA_GEN_FC

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20065535
Range
0 to 200 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Generator output voltage GX_IA_GEN_V

  • Service 22DID 16E9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Glass humidity GX_GLASS_HUMIDITY

  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Glass temperature GX_GLASS_T

  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9500−557.8
Range
-557 to 621 °F
Unit
°F

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

HV communication open GX_HV_COMMUNICATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

ICE, actual torque GX_ICE_ACT_TQ

  • Service 21PID CD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.000051319−128.006569
Range
-128 to 127 N·m
Unit
N·m

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle control GX_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle spark advance control 1 GX_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle spark advance control 2 GX_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle spark advance control 3 GX_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle spark advance control 4 GX_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle spark advance control, cylinder 1 GX_IDLE_SAC_CYL_1

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Idle spark advance control, cylinder 2 GX_IDLE_SAC_CYL_2

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Idle spark advance control, cylinder 3 GX_IDLE_SAC_CYL_3

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Idle spark advance control, cylinder 4 GX_IDLE_SAC_CYL_4

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Idle speed control learning GX_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Idle speed control learning value, l/s GX_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

IG OFF elapsed time GX_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ignition advance GX_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ignition advance GX_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ignition correction, cylinder 1 GX_IA_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Immobilizer communication on GX_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Initial engine coolant temperature GX_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Initial intake air temperature GX_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection GX_INJECTIONConfirmed

  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → DIRECT

States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Injection duration for cylinder 1 GX_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 1 GX_INJ_FEEDBACK_1

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 1 GX_INJ_FEEDBACK_1_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 2 GX_INJ_FEEDBACK_2

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 2 GX_INJ_FEEDBACK_2_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 3 GX_INJ_FEEDBACK_3

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 3 GX_INJ_FEEDBACK_3_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 4 GX_INJ_FEEDBACK_4

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 4 GX_INJ_FEEDBACK_4_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 5 GX_INJ_FEEDBACK_5

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection feedback value 6 GX_INJ_FEEDBACK_6

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume GX_INJ_VOLConfirmed

  • Service 22DID 1017
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val3200
Range
0 to 20 L
Unit
L

0x0000 = 0 → 03200 = 0 L

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Injection volume - target GX_INJ_VOLUME_TGT

  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume 1 GX_INJ_VOLUME_1

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume 2 GX_INJ_VOLUME_2

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume 3 GX_INJ_VOLUME_3

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume 5 GX_INJ_VOLUME_5

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume 6 GX_INJ_VOLUME_6

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume per 10 injections, cylinder 1 GX_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injection volume total GX_INJ_VOLUME_TOT

  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injector port GX_INJECTOR_PORTConfirmed

  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

0x0000 = 0 → 01000 = 0 ms

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Injector pulse width GX_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Injector pulse width GX_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Input shaft speed GX_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake air GX_INTAKE_AIR

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake air temperature GX_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake air temperature, bank 1 sensor 1 GX_IAT_B1S1Confirmed

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x29 = 41 → 41−40 = 1 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Intake air temperature, bank 1 sensor 2 GX_IAT_B1S2Confirmed

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Intake temperature fault GX_IA_IAT_FAULT

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake temperature sensor voltage GX_IA_IAT_SENS_V

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake temperature, alternate GX_IA_IAT_ALT2

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake VVT change angle, bank 1 GX_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed

  • Service 22DID 1087
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Intake VVT most over-retarded learn value, bank 1 GX_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed

  • Service 22DID 108D
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

0x0BF7 = 3063 → 3063×639.9965535 = 29.912098 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Intake VVT target angle B1 GX_INTAKE_VVT_TARGET_ANGLE_B1Confirmed

  • Service 22DID 106F
  • Module700 → 708
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Integrated engine run time GX_INTEGRATED_ENG_RUN

  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intercooler coolant temperature GX_INTERCOOLER_ECT

  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intercooler water pump GX_INTERCOOLER_WATERConfirmed

  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8013107
Range
0 to 300 %
Unit
%

0x0000 = 0 → 0×8013107 = 0 %

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Internal temperature GX_ECU_INTERNAL_TConfirmed

  • Service 22DID 105E
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x1E = 30 → 30−40 = -10 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Judge time engine ignition GX_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Judge time engine output GX_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock adjust GX_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock adjust GX_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock correct learn value GX_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock correction, learned value GX_KNOCK_CORRECT_LEARNED_VALUEConfirmed

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

0x8220 = 33312 → 33312×312.510000−1024 = 17

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Knock feedback GX_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock feedback GX_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock feedback value GX_KNOCK_FEEDBACK_VALUEConfirmed

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

0x7FA0 = 32672 → 32672×312.510000−1024 = -3

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Lock up state GX_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Long FT B1S1 GX_LONG_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Long-term fuel trim, bank 1 GX_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Main idle GX_MAIN_IDLE

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Manifold absolute pressure GX_MAP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Manifold pressure GX_IA_MAP_7E0

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Mass air flow GX_MAF

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Mass air flow GX_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Master cylinder open GX_MASTER_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire load GX_MISFIRE_LOAD_700Confirmed

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×510255
Range
0 to 510 %
Unit
%

0x00 = 0 → 0×510255 = 0 %

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Misfire margin GX_MISFIRE_MARGIN_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 rpm
Unit
rpm

In testing for 2003 to 2022, 2025 to 2026. Supported for 2024. Not supported for 2023.

Misfire RPM GX_MISFIRE_RPM_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6375255
Range
0 to 6375 rpm
Unit
rpm

In testing for 2003 to 2022, 2025 to 2026. Supported for 2024. Not supported for 2023.

Misfire test result, incomplete GX_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Model year GX_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

O2 heater b1s2_active GX_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

O2 heater current val bank 1 sensor 2 GX_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

O2S, bank 1 sensor 2 GX_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Open side malfunction on GX_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Output shaft speed GX_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

OXS1, A/FS2 test result, incomplete GX_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Oxygen sensor voltage, bank 1 sensor 1 GX_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

PM accumulation ratio - bank 1 GX_PM_ACCUMULATION_RAT_1

  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 15 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Purge cut vacuum switching valve duty GX_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Racing operation GX_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Regulator pressure GX_REGULATOR_P

  • Service 21PID 53
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×37510525500−456.68
Range
-456.68 to 3294 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Request engine run time GX_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Request warm-up GX_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Requested engine torque GX_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rough idle, cylinder 1 GX_ROUGH_IDLE_CYL_1Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x01 = 1 → 1 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Rough idle, cylinder 2 GX_ROUGH_IDLE_CYL_2Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x00 = 0 → 0 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Rough idle, cylinder 3 GX_ROUGH_IDLE_CYL_3Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x3F = 63 → 63 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Rough idle, cylinder 4 GX_ROUGH_IDLE_CYL_4Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x00 = 0 → 0 °

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Short FT B1S1 GX_SHORT_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Starter relay on GX_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Stroke open GX_STROKE_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Synchronize stroke sensor position GX_SYNCHRONIZE_STROKE

  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25665535
Range
0 to 256 mm
Unit
mm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

System guard on GX_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle control desired GX_IA_ETC_DSD_DEG

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle fully close learn GX_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle idle position on GX_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle motor current GX_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle motor duty GX_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle motor duty, close GX_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle motor duty, open GX_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position GX_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position 1 voltage GX_IA_TP1_V

  • Service 22DID 0917
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position 2 voltage GX_IA_TP2_V

  • Service 22DID 0918
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position actual GX_IA_ETC_ACT_DEG

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position command GX_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position, number 1 GX_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle position, number 2 GX_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle require position GX_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle sensor 2 voltage GX_THROTTL_SENSOR__2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle sensor open position 1 GX_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle sensor open position 2 GX_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle sensor position GX_THROTTLE_SENSOR_POSITION

Pelican can show this parameter as the throttle position.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle sensor voltage GX_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Time after DTC cleared GX_TIME_AFTER_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Total fuel trim, bank 1 GX_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid post-converter temperature GX_TF2_CONV

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1628
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00703125−40
Range
-40 to 350 °F
Unit
°F

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Transmission fluid temperature GX_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Transmission output shaft speed GX_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Turbine speed GX_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Valvematic current angle GX_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Valvematic, target angle GX_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing aim angle 1 GX_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing change angle 1 GX_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing control status 1 on GX_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing duty ratio, bank 1 GX_VVT_IE_DUTY_RATIO_BANK_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535−200
Range
-200 to 199 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing oil control valve duty 1 GX_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Variable valve timing oil temperature GX_VVTOTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Variable valve timing opening angle bank 1 GX_VVT_IE_OPENING_ANGLE_BANK_1

  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle load GX_VEHICLE_LOAD

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle speed GX_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle speed sensor test result, incomplete GX_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Warm-up cycles since DTCs cleared GX_WARMUP_CYCLE_CLEARED_DTC

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Warm-ups since DTC clear GX_IA_WARMUP_CLR

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst

Catalyst temperature, bank 1 sensor 1 GX_CAT_T_11Confirmed

  • Service 22DID 1F3C
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x01D2 = 466 → 46610−40 = 6.6 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Catalyst temperature, bank 1 sensor 2 GX_CAT_T_12Confirmed

  • Service 22DID 1F3E
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x0174 = 372 → 37210−40 = -2.8 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Misfires

All cylinders misfire count GX_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder #1 misfire count GX_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder #2 misfire count GX_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder #3 misfire count GX_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cylinder #4 misfire count GX_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire count, all GX_MIS_ALLConfirmed

  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Misfire count, cylinder 1 GX_MIS_1

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Misfire count, cylinder 2 GX_MIS_2

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Misfire count, cylinder 3 GX_MIS_3

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Misfire count, cylinder 4 GX_MIS_4

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Misfire load GX_MISFIRE_LOAD

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire margin GX_MISFIRE_MARGIN

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fluids

Distance since oil change GX_OIL_CHANGE_ODO

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel

Engine fuel rate GX_ENG_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel cut GX_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel cut GX_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel cut time GX_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel injection timing GX_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level GX_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1F2F
  • Module700 → 708
  • Every30 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x0E = 14 → 14×100255 = 5.490196 %

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Fuel level GX_IA_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level, volume GX_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x00 = 0 → 02 = 0 L

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Fuel pressure 1 GX_FUEL_P_1

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 1 GX_FUEL_P_1_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 2 GX_FUEL_P_2

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 2 GX_FUEL_P_2_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 3 GX_FUEL_P_3

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 3 GX_FUEL_P_3_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 4 GX_FUEL_P_4

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 4 GX_FUEL_P_4_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 5 GX_FUEL_P_5

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure 6 GX_FUEL_P_6

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pump duty ratio GX_FUEL_PUMP_DUTY_RATIOConfirmed

  • Service 22DID 106A
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0609756098
Range
0 to 3996 kPa
Unit
kPa

0x01EC = 492 → 492×0.0609756098 = 30 kPa

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pump/speed status on GX_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel remaining GX_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

0x0254 = 596 → 596100 = 5.96 L

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Fuel return temperature GX_FUEL_RETURN_T

  • Service 22DID 1141
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 1 GX_FUEL_T_1

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 1 GX_FUEL_T_1_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 2 GX_FUEL_T_2

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 2 GX_FUEL_T_2_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 3 GX_FUEL_T_3

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 3 GX_FUEL_T_3_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 4 GX_FUEL_T_4

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 4 GX_FUEL_T_4_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 5 GX_FUEL_T_5

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel temperature 6 GX_FUEL_T_6

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

High fuel pressure, actual GX_HFP_ACTUALConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x011C = 284 → 284×10 = 2,840 kPa

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

High fuel pressure, target GX_HFP_TARGETConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0190 = 400 → 400×10 = 4,000 kPa

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Low fuel pressure GX_LOW_FUEL_PRESSUREConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0028 = 40 → 40×10 = 400 kPa

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Low fuel pressure sensor GX_LFPSConfirmed

  • Service 22DID 10CD
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.75
Range
-3276 to 3276 kPa
Unit
kPa

0x8D27 = 36135 → 3613510−3276.75 = 336.75 kPa

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Reservoir warning GX_RESERVOIR_WARNING

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Target air-fuel ratio GX_TARGET_AIR_FUEL_RATIO

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle fuel rate GX_VEH_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA

Octane adjust ratio GX_IA_OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_AAT

Ambient air temperature sensor voltage GX_IA_AAT_V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_ACC

Accelerator pedal position GX_IA_ACC_POS

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_CL

Closed loop lambda correction GX_IA_CL_LC

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_HPFP

High pressure fuel pressure desired GX_IA_HPFP_DES

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.450377397
Range
0 to 3500 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

High pressure fuel rail sensor voltage GX_IA_HPFP_V

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val204.6
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_LPFP

Low pressure fuel pump commanded duty cycle GX_IA_LPFP_DUTY

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_MAP

Manifold absolute pressure sensor voltage GX_IA_MAP_V

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_RO2

Rear O2 voltage GX_IA_RO2_V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_VCT_EXH

Exhaust camshaft solenoid duty cycle GX_IA_VCT_EXH_DUTY

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Exhaust camshaft timing, actual GX_IA_VCT_EXH_ACT

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

GX_IA_VCT_INT

Intake camshaft solenoid duty cycle GX_IA_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intake camshaft timing, actual GX_IA_VCT_INT_ACT

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 60 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lights

Hazard switch history GX_HAZARD_SWITCH_HISTORY

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rheostat GX_RHEOSTAT

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Stop light GX_STOP_LIGHT

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Stop light relay GX_STOP_LIGHT_RELAY

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Stop light switch GX_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Movement

Accelerator fully close learn 1 GX_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator fully close learn 2 GX_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator idle position on GX_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator position GX_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator sensor out, number 1 GX_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Accelerator sensor out, number 2 GX_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Average engine speed of all cylinders GX_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Compressor speed GX_COMP_SPD

  • Service 21PID 49
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Compressor, target speed GX_COMP_TGT_SPD

  • Service 21PID 4A
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cruise control speed GX_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed GX_ENGINE_SPEED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 16383 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed of cylinder 1 GX_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed of cylinder 2 GX_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed of cylinder 3 GX_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine speed of cylinder 4 GX_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front left wheel acceleration GX_FL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front left wheel speed GX_TIRE_FL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front left wheel speed? GX_FL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right wheel acceleration GX_FR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right wheel speed GX_TIRE_FR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front right wheel speed? GX_FR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

High voltage, target engine speed GX_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Intercooler water pump speed, raw count GX_IWP_SPEEDConfirmed

  • Service 22DID 1075
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x80CD = 32973 → 32,973

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Minimum engine speed GX_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire RPM GX_MISFIRE_RPM

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

NC1 speed GX_NC1_SPD

  • Service 22DID 1614
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

NO speed GX_NO_SPD

  • Service 22DID 1618
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

NSS speed GX_NSS_SPD

  • Service 22DID 1616
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

NT speed GX_NT_SPD

  • Service 22DID 161A
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left wheel acceleration GX_RL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left wheel speed GX_TIRE_RL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear left wheel speed? GX_RL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel acceleration GX_RR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel speed GX_TIRE_RR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear right wheel speed? GX_RR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle speed GX_IA_VSS

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle speed GX_VEHICLE_SPEED

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle speed GX_VSS_V1Confirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.28
Range
0 to 326 km/h
Unit
km/h

0x00 = 0 → 0×1.28 = 0 km/h

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Vehicle speed, 7C0 GX_VSS_7C0

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Orientation

Deceleration open GX_DECELERATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Deceleration sensor GX_DECEL

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Deceleration sensor, alternate GX_DECEL2

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lateral g GX_LAT_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Longitudinal g GX_LNG_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Yaw rate open error? GX_YAW_RATE_ERROR

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Yaw rate sensor GX_YAW_RATE_7B0

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Yaw rate sensor, alternate GX_YAW_RATE2

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Yaw rate value (degrees/se GX_YAW_RATEConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

0x7D = 125 → 125−128 = -3 °

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Zero point of yaw rate GX_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Seatbelts

P-seatbelt buckle GX_P_SEATBELT_BUCKLE

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Reverse beep GX_REVERSE_BEEP

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Seat belt beeps GX_SEAT_BELT_BEEP

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Tires

Brake assist status GX_BA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front left tire pressure GX_TP_FL_V1Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front left tire pressure GX_TP_FL_V2Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.8 bar
Unit
bar

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Front left tire temperature GX_TT_FLConfirmed

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front left tire temperature GX_TT_FL_V2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Front left wheel ABS status GX_FL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front left wheel stability control GX_FL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right tire pressure GX_TP_FR_V1Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front right tire pressure GX_TP_FR_V2Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.8 bar
Unit
bar

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Front right tire temperature GX_TT_FRConfirmed

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Front right tire temperature GX_TT_FR_V2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Front right wheel ABS status GX_FR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right wheel cylinder open GX_FR_WHEEL_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Front right wheel stability control GX_FR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Predictive brake assist status GX_PBA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left tire pressure GX_TP_RL_V1Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear left tire pressure GX_TP_RL_V2Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.8 bar
Unit
bar

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Rear left tire temperature GX_TT_RLConfirmed

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear left tire temperature GX_TT_RL_V2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Rear left wheel ABS status GX_RL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left wheel EBS status GX_RL_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear left wheel stability control GX_RL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right tire pressure GX_TP_RR_V1Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear right tire pressure GX_TP_RR_V2Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.8 bar
Unit
bar

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Rear right tire temperature GX_TT_RRConfirmed

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Rear right tire temperature GX_TT_RR_V2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Rear right wheel ABS status GX_RR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel EBS status GX_RR_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel stability control GX_RR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Spare tire pressure GX_TP_SPARE_V1Confirmed

  • Service 21PID 30
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Spare tire pressure GX_TP_SPARE_V2Confirmed

  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.8 bar
Unit
bar

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Spare tire temperature GX_TT_SPAREConfirmed

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Spare tire temperature GX_TT_SPARE_V2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Tire 1 position GX_TID_1Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → FL

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Tire 2 position GX_TID_2Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states

0x02 = 2 → FR

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Tire 3 position GX_TID_3Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 16 to 23 of the reply, 8 bits.

Unit
Named states

0x03 = 3 → RL

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Tire 4 position GX_TID_4Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 24 to 31 of the reply, 8 bits.

Unit
Named states

0x04 = 4 → RR

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Tire pressure 1, set 2 GX_TIRE_P_1_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Tire pressure 2, set 2 GX_TIRE_P_2_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Tire pressure 3, set 2 GX_TIRE_P_3_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Tire pressure 4, set 2 GX_TIRE_P_4_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Tire pressure 5, set 2 GX_TIRE_P_5_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023 to 2024.

Torque converter turbine wheel speed GX_TQ_CONV_TURBINE_WHL

  • Service 21PID DA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12750
Range
0 to 6 rpm
Unit
rpm

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Wheel cylinder pressure GX_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission

Current gear GX_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Gear GX_GEARConfirmed

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

0x01 = 1 → 1

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Gear GX_GEAR_700Confirmed

  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Gear lock-up GX_GEAR_LOCKUPConfirmed

Mechanism within the automatic transmission that momentarily locks the gears during gear changes, providing a smoother and more efficient transition between different gears, especially when accelerating or decelerating; essentially helps minimize power loss and jerkiness during gear shifts.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Gear, engaged GX_IA_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lock up state GX_AT_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Torque converter and TE1 on GX_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid post-converter temperature, variant 3 GX_TRANS_FLUID_POST_T_3

  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, pan GX_ATF_T_PANConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module701 → 709
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x2200 = 8704 → 8704256−40 = -6 °C

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Transmission fluid temperature, pan var.3 GX_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module700 → 708
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x0000 = 0 → 0256−40 = -40 °C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Transmission fluid temperature, variant 5 GX_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 8 GX_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 9 GX_ATF_T_V_9

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 10 GX_ATF_T_V_10_7E1

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 11 GX_ATF_T_V_11

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 12 GX_ATF_T_V_12

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 14 GX_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 14 GX_ATF_T_V_14_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 21 GX_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, variant 21 GX_ATF_T_V_21_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission oil pressure calibration, complete GX_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission shift state ratio GX_TRANS_SHIFT_ST_RAT

  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission shift state ratio GX_TRANS_SHIFT_ST_RAT_701

  • Service 22DID 1622
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission temperature GX_IA_TRANS_T_V6

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×980+32
Range
0 to 7000 °F
Unit
°F

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Transmission temperature, pan GX_ATF_PAN_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x3660 = 13920 → 13920256−40 = 14.375 °C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Transmission temperature, torque converter GX_ATF_TQC_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x38E0 = 14560 → 14560256−40 = 16.875 °C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Trips

Odometer GX_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module700 → 708
  • Every30 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x008658 = 34392 → 34,392 km

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Odometer GX_IA_ODO

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Odometer GX_ODO_7E0Confirmed

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2022, 2024 to 2026

Example reply from a 2023 Lexus GX 460.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x00D375 = 54133 → 54,133 km

Confirmed for 2023. In testing for 2010 to 2022, 2025 to 2026. Not supported for 2024.

Odometer GX_ODO_V5Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module701 → 709
  • Every10 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Lexus GX 460.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000000 = 0 → 0 km

Confirmed for 2024. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2023.

Previous trip distance GX_PREV_TRIP_DSTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2022, 2024 to 2026

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Vehicle odometer GX_IA_PCM_VEH_ODO

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.