Parameters
The Mazda CX-60 has 285 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery state of charge CX60_12V_SOC_723Confirmed
- Service 22
DID DCE2 - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
12V battery voltage CX60_12V_VOLTAGEConfirmed
- Service 22
DID D90E - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
0x0494 = 1172 → = 11.72 V
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Battery pack voltage CX60_HVBAT_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 480D - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
0x7A53 = 31315 → = 313.15 V
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Battery voltage CX60_BAT_V_7E0Confirmed
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
0x3643 = 13891 → = 13.891 V
Confirmed for 2022. In testing for 2023 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2023 to 2024. Supported for 2022.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 13 to 14 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
3 | Not PSA |
Confirmed for 2023. Supported for 2024.
High voltage battery state of charge CX60_HV_EV_BATT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID D914 - Module
723 → 72B - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0050 = 80 → = 8 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2024.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2023. Supported for 2024.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2023. Supported for 2024.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2023. Supported for 2024.
Voltage supply CX60_V_SUPConfirmed
- Service 22
DID D901 - Module
737 - Every
5 s - Testing for 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20.4 V
- Unit
- V
Confirmed for 2022. In testing for 2023 to 2026.
Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2024.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2024.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2024.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2024.
Climate
A/C compressor pressure CX60_AC_PConfirmed
- Service 22
DID 0393 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 psi
- Unit
- psi
0x0112 = 274 → = 79.480686 psi
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
A/C compressor pressure sensor voltage CX60_AC_P_SENS_VConfirmed
- Service 22
DID 9800 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
A/C compressor, state CX60_AC_STATEConfirmed
- Service 22
DID 099B - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0x00 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Ambient air temperature CX60_AATConfirmed
- Service 22
DID DD05 - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3E = 62 → = 22 °C
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Ambient temperature, alternate CX60_AAT_ALTConfirmed
- Service 22
DID 057D - Module
7E0 → 7E8 - Every
5 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x56 = 86 → = 3 °C
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2023 to 2024. Supported for 2022.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Brake hydraulic pressure, raw count CX60_BRK_FL_PConfirmed
- Service 22
DID 2B0D - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Brake switch CX60_BRAKE_SWITCHConfirmed
- Service 22
DID DA05 - Module
726 → 72E - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Parking brake state CX60_PARKING_BRAKE_760Confirmed
- Service 22
DID 2B00 - Module
760 → 768 - Every
3 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2022.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
CX60
Octane adjust ratio CX60_OARConfirmed
- Service 22
DID 03E8 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 1
- Unit
- Number
0x0000 = 0 → = 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
CX60_AAT
Ambient air temperature sensor voltage CX60_AAT_VConfirmed
- Service 22
DID 03BA - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0x00C3 = 195 → = 0.953079 V
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
CX60_ACC
Accelerator pedal position CX60_ACC_POSConfirmed
- Service 22
DID 032B - Module
7E0 → 7E8 - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
CX60_CL
Closed loop lambda correction CX60_CL_LCConfirmed
- Service 22
DID 03BD - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4 to 3.9
- Unit
- Number
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
CX60_HPFP
High pressure fuel pressure desired CX60_HPFP_DESConfirmed
- Service 22
DID 03DC - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6000 psi
- Unit
- psi
0x0258 = 600 → = 870.226438 psi
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
High pressure fuel rail sensor voltage CX60_HPFP_VConfirmed
- Service 22
DID 0324 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
CX60_RO2
Rear O2 voltage CX60_RO2_VConfirmed
- Service 22
DID 035F - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 V
- Unit
- V
0x0000 = 0 → = 0 V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
CX60_VCT_EXH
Variable camshaft timing, exhaust camshaft actual CX60_VCT_EXH_ACTConfirmed
- Service 22
DID 0319 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Variable camshaft timing, exhaust camshaft solenoid duty cycle CX60_VCT_EXH_DUTYConfirmed
- Service 22
DID 0317 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
CX60_VCT_INT
Variable camshaft timing, intake camshaft actual CX60_VCT_INT_ACTConfirmed
- Service 22
DID 0318 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Variable camshaft timing, intake camshaft solenoid duty cycle CX60_VCT_INT_DUTYConfirmed
- Service 22
DID 0316 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022 to 2024.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2023. Supported for 2022, 2024.
DTC that caused required freeze frame data storage DTCFRZFSAE J1979Confirmed
0 indicates no freeze frame data.
- Service 01
PID 02 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Hexadecimal
Confirmed for 2023. Supported for 2022, 2024.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. Supported for 2022, 2024.
Number of DTCs CX60_DTC_CNTDConfirmed
- Service 22
DID 0202 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2023. Supported for 2022, 2024.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. Supported for 2022, 2024.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2022, 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2023. Supported for 2022, 2024.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2023. Supported for 2022, 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Electrical
Tailgate power supply CX60_TAILGATE_POWER_SUPConfirmed
- Service 22
DID D111 - Module
775 → 77D - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x80 = 128 → = 12.8 V
Confirmed for 2022. In testing for 2023 to 2026.
Engine
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2024.
Accelerator pedal position CX60_APP_ECMConfirmed
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x28 = 40 → = 15.686275 %
Confirmed for 2022. In testing for 2023 to 2026.
Actual engine percent torque CX60_PCM_ACT_ENG_PCT_TRQConfirmed
- Service 22
DID F462 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x7D = 125 → = 0 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2023.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2023.
APP sensor 1 voltage CX60_APP1_VConfirmed
- Service 22
DID 0914 - Module
7E0 → 7E8 - Every
500 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x0318 = 792 → = 0.792 V
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
APP sensor 2 voltage CX60_APP2_VConfirmed
- Service 22
DID 0915 - Module
7E0 → 7E8 - Every
500 ms - Testing for 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024.
Barometric pressure CX60_BAROMETRIC_PConfirmed
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
0x61 = 97 → 97 kPa
Confirmed for 2022. In testing for 2023 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. Supported for 2022.
Catalyst damaging misfires total during this trip CX60_CATDMG_MIS_TOTConfirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Catalyst damaging misfires, cylinder 1 CX60_CATDMG_MIS_1Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Catalyst damaging misfires, cylinder 2 CX60_CATDMG_MIS_2Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Catalyst damaging misfires, cylinder 3 CX60_CATDMG_MIS_3Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Catalyst damaging misfires, cylinder 4 CX60_CATDMG_MIS_4Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Catalyst temperature CX60_CAT_TEMPConfirmed
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x027E = 638 → = 23.8 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2023. Supported for 2022, 2024.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2024.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Control module power supply CX60_CTRL_MODULE_POWERConfirmed
- Service 22
DID D111 - Module
733 → 73B - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x83 = 131 → = 13.1 V
Confirmed for 2022. In testing for 2023 to 2026.
Coolant temperature CX60_7E3_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID F405 - Module
7E3 → 7EB - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3B = 59 → = 19 °C
Confirmed for 2022. In testing for 2023 to 2026.
Cylinder 1 misfire average CX60_MIS_AVG_1Confirmed
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x2440 = 9280 → 9,280
Confirmed for 2022. In testing for 2023 to 2026.
Cylinder 2 misfire average CX60_MIS_AVG_2Confirmed
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x000E = 14 → 14
Confirmed for 2022. In testing for 2023 to 2026.
Cylinder 3 misfire average CX60_MIS_AVG_3Confirmed
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0xD81E = 55326 → 55,326
Confirmed for 2022. In testing for 2023 to 2026.
Cylinder 4 misfire average CX60_MIS_AVG_4
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026. Supported for 2022.
Cylinder 5 misfire average CX60_MIS_AVG_5
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026. Supported for 2022.
Cylinder 6 misfire average CX60_MIS_AVG_6
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026. Supported for 2022.
Cylinder 7 misfire average CX60_MIS_AVG_7
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026. Supported for 2022.
Cylinder 8 misfire average CX60_MIS_AVG_8
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026. Supported for 2022.
Cylinder head temperature CX60_CYL_HEAD_T_7E0_2Confirmed
- Service 22
DID F405 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3B = 59 → = 19 °C
Confirmed for 2022. In testing for 2023 to 2026.
Distance since DTC clear CX60_DIST_DTC_CLRConfirmed
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x012E = 302 → 302 km
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Distance with MIL CX60_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Emission failure misfires total during this trip CX60_EMISSION_FAILURE_MISConfirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Emission failure misfires, cylinder 1 CX60_EMISSION_FAILURE_MIS_1Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Emission failure misfires, cylinder 2 CX60_EMISSION_FAILURE_MIS_2Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Emission failure misfires, cylinder 3 CX60_EMISSION_FAILURE_MIS_3Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Emission failure misfires, cylinder 4 CX60_EMISSION_FAILURE_MIS_4Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2024. Supported for 2022.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2023.
Engine load CX60_ENG_LOAD_PCTConfirmed
Pelican can show this parameter as the engine load.
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine load, actual CX60_ENG_LOAD_ACTConfirmed
Pelican can show this parameter as the engine load.
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine oil pressure CX60_EOPConfirmed
- Service 22
DID 0415 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
0x0000 = 0 → 0 kPa
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine oil temperature CX60_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1310 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 615.35 °C
- Unit
- °C
0x1871 = 6257 → = 22.57 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine reference torque CX60_PCM_ENG_REFERENCE_TRQConfirmed
- Service 22
DID F463 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x012C = 300 → 300 N·m
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2023.
Engine RPM CX60_ENGINE_RPMConfirmed
- Service 22
DID F40C - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2022 to 2023. Supported for 2024.
Engine run time CX60_ENGINE_RUN_TIMEConfirmed
- Service 22
DID F41F - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0000 = 0 → 0 s
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Engine run time CX60_RUN_TIMEConfirmed
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0000 = 0 → 0 s
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Engine runtime CX60_IG_ON_TIMERConfirmed
- Service 22
DID DCE1 - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1092.25 min
- Unit
- min
0x0000 = 0 → = 0 min
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Engine speed CX60_RPMConfirmed
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Evaporative purge CX60_EVAP_PURGE_CMDConfirmed
- Service 22
DID 1166 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Fuel pressure FPSAE J1979Confirmed
- Service 01
PID 0A - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 765 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024.
Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.
- Service 01
PID 59 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023.
Fuel trim, long term CX60_LTFTConfirmed
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
0x7B = 123 → = -3.90625 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Fuel trim, short term CX60_STFTConfirmed
Pelican can show this parameter as the short term fuel trim.
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
0x6F = 111 → = -13.28125 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Generator field coil control duty CX60_GEN_FCConfirmed
- Service 22
DID 16E8 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Grill shutter duty cycle CX60_GRILL_SHUT_DCConfirmed
- Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Grill shutter position CX60_GRILL_SHUTTER_POSConfirmed
- Service 22
DID 0580 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Ignition angle before top dead center CX60_IGN_ANG_BTDCConfirmed
- Service 22
DID F40E - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5
- Unit
- Number
0x80 = 128 → = 0
Confirmed for 2022. In testing for 2023 to 2026.
Ignition correction, cylinder 1 CX60_IGN_CORR_CYL1Confirmed
- Service 22
DID 03EC - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -64 to 63.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2022, 2024.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023.
Intake shutter valve position CX60_INT_SHUTTER_VLV_POSConfirmed
- Service 22
DID F411 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x1C = 28 → = 10.980392 %
Confirmed for 2022. In testing for 2023 to 2026.
Intake temperature fault CX60_IAT_FAULTConfirmed
- Service 22
DID 0700 - Module
7E0 → 7E8 - Every
5 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Intake temperature sensor voltage CX60_IAT_SENS_VConfirmed
- Service 22
DID 1279 - Module
7E0 → 7E8 - Every
1 s - Testing for 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Intake temperature, alternate CX60_IAT_ALT2Confirmed
- Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x40 = 64 → = 24 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023.
Low oil pressure switch CX60_LOW_OIL_P_SWITCHConfirmed
- Service 22
DID 0416 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Manifold absolute pressure sensor voltage CX60_MAPConfirmed
A properly functioning sensor should read around 1 to 1.5 volts at idle.
- Service 22
DID 0301 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0x0300 = 768 → = 0.75 V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Manifold pressure CX60_MAP_7E0Confirmed
- Service 22
DID F40B - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36 psi
- Unit
- psi
0x14 = 20 → = 2.900779 psi
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2023.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2023.
Oil pressure solenoid valve, open CX60_OIL_P_SOLENOID_VLVConfirmed
- Service 22
DID DA01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2023 to 2026.
Power mode CX60_POWER_MODEConfirmed
- Service 22
DID DD06 - Module
726 → 72E - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -192 to 63
- Unit
- Number
0x00 = 0 → = -192
Confirmed for 2022. In testing for 2023 to 2026.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Seat buckle driver locked CX60_SEAT_BUCKLE_DRIVERConfirmed
- Service 22
DID 5B19 - Module
737 → 73F - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
0x02 = 2 → = 1
Confirmed for 2022. In testing for 2023 to 2026.
Seat buckle passenger locked CX60_SEAT_BUCKLEConfirmed
- Service 22
DID 5B1A - Module
737 → 73F - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2022. In testing for 2023 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023.
Slave A/T CX60_SLAVE_TConfirmed
- Service 22
DID 1E1B - Module
7E1 → 7E9 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2022. In testing for 2023 to 2026.
Steering angle, actual value CX60_STEER_ANG_ACTConfirmed
- Service 22
DID 3302 - Module
760 → 768 - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
0x1173 = 4467 → = 446.7
Confirmed for 2022. In testing for 2023 to 2026.
Steering shaft torque CX60_STEER_SHFT_TQConfirmed
- Service 22
DID 330C - Module
730 → 738 - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12.7 to 12.8 N·m
- Unit
- N·m
0x5B = 91 → = -3.6 N·m
Confirmed for 2022. In testing for 2023 to 2026.
Throttle control desired CX60_ETC_DSD_DEGConfirmed
- Service 22
DID 091A - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.9 °
- Unit
- °
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Throttle position 1 voltage CX60_TP1_VConfirmed
- Service 22
DID 0917 - Module
7E0 → 7E8 - Every
500 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x01F2 = 498 → = 0.498 V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Throttle position 2 voltage CX60_TP2_VConfirmed
- Service 22
DID 0918 - Module
7E0 → 7E8 - Every
500 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x047A = 1146 → = 1.146 V
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Throttle position actual CX60_ETC_ACT_DEGConfirmed
- Service 22
DID 093C - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.9 °
- Unit
- °
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2023. Supported for 2022, 2024.
Torque, actual CX60_TQ_ACTConfirmed
- Service 22
DID 1EE4 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2023 to 2026.
Torque, desired CX60_TQ_DESConfirmed
- Service 22
DID 1EC7 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2023 to 2026.
Traction control switch indicator CX60_DTSC_SWITCHConfirmed
- Service 22
DID 2B05 - Module
760 → 768 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 2.98
- Unit
- Number
0x00 = 0 → = -1
Confirmed for 2022. In testing for 2023 to 2026.
Transmission oil temperature CX60_TOT_7E0
- Service 22
DID 1E1C - Module
7E0 → 7E8 - Every
5 s - Testing for 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 °C
- Unit
- °C
In testing for 2025 to 2026. Supported for 2023. Not supported for 2022, 2024.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2023.
Warm-ups since DTC clear CX60_WARMUP_CLRConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x09 = 9 → 9
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Yaw rate signal CX60_YAW_RATE_SIGConfirmed
- Service 22
DID 2B0B - Module
760 → 768 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2022. In testing for 2023 to 2026.
Internal
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023.
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2024.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2023. Supported for 2022, 2024.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2022 to 2024.
Fuel
Air/fuel ratio CX60_AIR_FUEL_RATConfirmed
- Service 22
DID F434 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.2801
- Unit
- Number
0x7EC2 = 32450 → = 14.498238
Confirmed for 2022. In testing for 2023 to 2026.
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2023.
Engine fuel rate CX60_ENG_FUEL_RATEConfirmed
- Service 22
DID F45E - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2022. In testing for 2023 to 2026.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2022 to 2024.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2023.
Fuel level CX60_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x52 = 82 → = 32.156863 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Fuel level CX60_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 61B1 - Module
720 → 728 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
0x00 = 0 → 0 L
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Fuel pressure CX60_FUEL_PConfirmed
- Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553500
- Unit
- Raw value
0x0041 = 65 → = 6,500
Confirmed for 2022. In testing for 2023 to 2026.
Fuel pump load CX60_FP_LDConfirmed
- Service 22
DID 0307 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0666 = 1638 → = 4.998779 %
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2023. Supported for 2022, 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2023. Supported for 2022, 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. Supported for 2022.
Fuel temperature CX60_FUEL_TConfirmed
- Service 22
DID 0522 - Module
7E0 → 7E8 - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x36 = 54 → = 14 °C
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2023.
Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023.
Movement
Front left wheel speed CX60_FL_VSSConfirmed
- Service 22
DID 2B07 - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Front right wheel speed CX60_FR_VSSConfirmed
- Service 22
DID 2B06 - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Lateral acceleration, raw count CX60_LAT_G_760Confirmed
- Service 22
DID 2B11 - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Lateral angle, raw count CX60_LAT_ANGConfirmed
- Service 22
DID 2B0C - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear left wheel speed CX60_RL_VSSConfirmed
- Service 22
DID 2B09 - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear right wheel speed CX60_RR_VSSConfirmed
- Service 22
DID 2B08 - Module
760 → 768 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Vehicle speed CX60_VEHICLE_SPEEDConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Vehicle speed CX60_VSSConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2023. Supported for 2022, 2024.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2023. Supported for 2022, 2024.
Tires
Front left pressure CX60_TP_FL_726Confirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID D922 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xBE = 190 → = 38 psi
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Front left temperature CX60_TT_FL_726Confirmed
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID D926 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x47 = 71 → = 21 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Front right pressure CX60_TP_FR_726Confirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID D923 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xC7 = 199 → = 39.8 psi
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Front right temperature CX60_TT_FR_726Confirmed
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID D927 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x47 = 71 → = 21 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear left pressure CX60_TP_RL_726Confirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID D924 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xC7 = 199 → = 39.8 psi
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear left temperature CX60_TT_RL_726Confirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID D928 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x47 = 71 → = 21 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear right pressure CX60_TP_RR_726Confirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID D925 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xB0 = 176 → = 35.2 psi
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Rear right temperature CX60_TT_RR_726Confirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID D929 - Module
726 → 72E - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x47 = 71 → = 21 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Steering wheel angle velocity CX60_STEER_WHL_ANGConfirmed
- Service 22
DID 3301 - Module
730 → 738 - Every
250 ms - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020
- Unit
- Raw value
0x00 = 0 → = 0
Confirmed for 2022. In testing for 2023 to 2026.
Transmission
AT, actual gear ratio CX60_ACT_GEAR_RATConfirmed
- Service 22
DID 1E16 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
0x0D29 = 3369 → = 0.82251
Confirmed for 2022 to 2023. In testing for 2024 to 2026.
Axle gear ratio, measured CX60_AXLE_GEAR_RATIO_MEAS
- Service 22
DID 1E16 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10
- Unit
- Number
In testing for 2025 to 2026. Supported for 2023. Not supported for 2022, 2024.
Current gear CX60_GEAR
The automatic transmission gear.
- Service 22
DID 1E12 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
In testing for 2025 to 2026. Supported for 2023. Not supported for 2022, 2024.
Gear CX60_GEAR_7E1Confirmed
- Service 22
DID 1E12 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Gear, engaged CX60_GEAR_ENGConfirmed
- Service 22
DID 1E1F - Module
7E0 → 7E8 - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.
Transmission fluid temperature CX60_TRANS_T_V6Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E1C - Module
7E1 → 7E9 - Every
1 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 °C
- Unit
- °C
0x0192 = 402 → = 25.125 °C
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Transmission fluid temperature, variant 2 CX60_ATF_T_VAR_2Confirmed
- Service 22
DID D904 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2026
Example reply from a 2022 Mazda CX-60.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0000 = 0 → 0 °C
Confirmed for 2022. In testing for 2023 to 2026.
Transmission odometer CX60_TRANS_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing for 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00AAFA = 43770 → 43,770 km
Confirmed for 2022 to 2023. In testing for 2024 to 2026.
Trips
Odometer CX60_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00A2C6 = 41670 → 41,670 km
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2023.
Odometer, instrument panel CX60_ODO_726Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
726 → 72E - Every
30 s - Testing for 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00A2C6 = 41670 → 41,670 km
Confirmed for 2022 to 2024. In testing for 2025 to 2026.
Total distance CX60_ODO_723Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
723 → 72B - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Mazda CX-60.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00A2C6 = 41670 → 41,670 km
Confirmed for 2022, 2024. In testing for 2025 to 2026. Not supported for 2023.
Vehicle odometer CX60_PCM_VEH_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID F4A6 - Module
7E0 → 7E8 - Every
30 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Mazda CX-60.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x0005F2AF = 389807 → = 38,980.7 km
Confirmed for 2023. In testing for 2025 to 2026. Not supported for 2022, 2024.