Mercedes-Benz CLA-Class

Parameters

The Mercedes-Benz CLA-Class has 89 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary battery voltage MERCEDES_AUX_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2018 Mercedes-Benz CLA-Class.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

0x00 = 0 → 0×25.9255 = 0 V

Confirmed for 2018. In testing for 2013 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V system voltage, hd MERCEDES_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 100 V
Unit
V

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Auxiliary battery voltage MERCEDES_AUX_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2018 Mercedes-Benz CLA-Class.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

0x00 = 0 → 0×25.9255 = 0 V

Confirmed for 2018. In testing for 2013 to 2017, 2019 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018. Supported for 2014.

DC converter requested voltage MERCEDES_CNVRTR_REQ_V

  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 100 V
Unit
V

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

HV battery amperage MERCEDES_HV_A

  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
0 to 100 A
Unit
A

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

HV battery coolant temperature MERCEDES_HV_COOLANT_T

  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
0 to 100 °C
Unit
°C

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

HV battery state of charge MERCEDES_HV_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

HV battery voltage MERCEDES_HV_V

  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 100 V
Unit
V

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Steering wheel angle MERCEDES_STEER_ANGLE

Positive is rotated to the right, negative is rotated to the left.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Pedals

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018. Supported for 2014.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. Supported for 2014.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2018. Supported for 2014.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2014.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018. Supported for 2014.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018. Supported for 2014.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2014.

Engine

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2014.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2018.

Distance to next service MERCEDES_SERVICE_DISTConfirmed

  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2018 Mercedes-Benz CLA-Class.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2018. In testing for 2013 to 2017, 2019 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. Supported for 2014.

Master break cylinder pressure MERCEDES_MASTER_BREAK_CYLINDER_PRESSURE

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val×15310000
Range
-500 to 500 bar
Unit
bar

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018.

Vacuum break pressure MERCEDES_VACUUM_BREAK_PRESSURE

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 bar
Unit
bar

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2018.

Fuel

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Movement

Front left wheel speed MERCEDES_FL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Front left wheel speed MERCEDES_TIRE_FL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Front right wheel speed MERCEDES_FR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Front right wheel speed MERCEDES_TIRE_FR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Rear left wheel speed MERCEDES_RL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Rear left wheel speed MERCEDES_TIRE_RL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Rear right wheel speed MERCEDES_RR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Rear right wheel speed MERCEDES_TIRE_RR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2018. Supported for 2014.

Orientation

Lateral acceleration MERCEDES_LAT_ACC

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×15.6251000
Range
-512 to 511 g
Unit
g

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Lateral acceleration MERCEDES_LAT_G

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val627.6
Range
-52.21 to 52.21 g
Unit
g

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Longitudinal acceleration MERCEDES_LNG_G

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val192747
Range
-0.17 to 0.17 g
Unit
g

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Longitudinal acceleration MERCEDES_LON_ACC

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.63 to 1.63 g
Unit
g

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Master break cylinder pressure MERCEDES_MCYL_BREAK

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val65.35883831
Range
-501.34 to 501.34 bar
Unit
bar

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Vaccuum cylinder pressure MERCEDES_VACC_BREAK

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32 to 32 bar
Unit
bar

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Yaw rate MERCEDES_YAW_RATE

The angular velocity of the car around its vertical axis. Indicates how quickly the car is rotating to its left or right.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×232767
Range
-2 to 2 rad
Unit
rad

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Trips

HV battery remaining distance MERCEDES_HV_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 2013 to 2017, 2019 to 2026. Not supported for 2018.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.