Parameters
The MG RX9 has 76 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2025.
Knock sensor voltage RX9_KNOCK_SNS_VConfirmed
- Service 22
DID B140 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0x00 = 0 → = 0 V
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025.
ECU
Engine module B001 raw value RX9_ECM_B001_RAWConfirmed
- Service 22
DID B001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0CE4 = 3300 → 3,300
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B003 raw value RX9_ECM_B003_RAWConfirmed
- Service 22
DID B003 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0236 = 566 → 566
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B009 raw value RX9_ECM_B009_RAWConfirmed
- Service 22
DID B009 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x8029 = 32809 → 32,809
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B010 raw value RX9_ECM_B010_RAWConfirmed
- Service 22
DID B010 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x45 = 69 → 69
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B011 raw value RX9_ECM_B011_RAWConfirmed
- Service 22
DID B011 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x58 = 88 → 88
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B013 raw value RX9_ECM_B013_RAW
- Service 22
DID B013 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
Engine module B019 raw value RX9_ECM_B019_RAWConfirmed
- Service 22
DID B019 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B026 raw value RX9_ECM_B026_RAW
- Service 22
DID B026 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine module B029 raw value RX9_ECM_B029_RAWConfirmed
- Service 22
DID B029 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00A2 = 162 → 162
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B041 raw value RX9_ECM_B041_RAWConfirmed
- Service 22
DID B041 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x13D0 = 5072 → 5,072
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B042 raw value RX9_ECM_B042_RAWConfirmed
- Service 22
DID B042 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0122 = 290 → 290
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B045 raw value RX9_ECM_B045_RAWConfirmed
- Service 22
DID B045 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x07 = 7 → 7
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B046 raw value RX9_ECM_B046_RAWConfirmed
- Service 22
DID B046 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00A7 = 167 → 167
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B049 raw value RX9_ECM_B049_RAW
- Service 22
DID B049 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine module B052 raw value RX9_ECM_B052_RAW
- Service 22
DID B052 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
Engine module B058 raw value RX9_ECM_B058_RAW
- Service 22
DID B058 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine module B059 raw value RX9_ECM_B059_RAWConfirmed
- Service 22
DID B059 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0xF0E7 = -3865 → -3,865
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B061 raw value RX9_ECM_B061_RAWConfirmed
- Service 22
DID B061 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B101 raw value RX9_ECM_B101_RAWConfirmed
- Service 22
DID B101 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x30CD = 12493 → 12,493
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B110 raw value RX9_ECM_B110_RAWConfirmed
- Service 22
DID B110 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0004 = 4 → 4
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B111 raw value RX9_ECM_B111_RAWConfirmed
- Service 22
DID B111 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0012 = 18 → 18
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module B120 raw value RX9_ECM_B120_RAW
- Service 22
DID B120 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2023 to 2026.
Engine module B401 raw value RX9_ECM_B401_RAW
- Service 22
DID B401 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Engine module B705 raw value RX9_ECM_B705_RAW
- Service 22
DID B705 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2023 to 2026.
Engine module B712 raw value RX9_ECM_B712_RAW
- Service 22
DID B712 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine module B921 raw value RX9_ECM_B921_RAWConfirmed
- Service 22
DID B921 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
0x000002D0 = 720 → 720
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine module D001 raw value RX9_ECM_D001_RAWConfirmed
- Service 22
DID D001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x77 = 119 → 119
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Module 7EA D001 raw value RX9_7EA_D001_RAWConfirmed
- Service 22
DID D001 - Module
7E2 → 7EA - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x77 = 119 → 119
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B00F raw value RX9_TCM_B00F_RAWConfirmed
- Service 22
DID B00F - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x40 = 64 → 64
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B001 raw value RX9_TCM_B001_RAWConfirmed
- Service 22
DID B001 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B003 raw value RX9_TCM_B003_RAWConfirmed
- Service 22
DID B003 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x5E = 94 → 94
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B04A raw value RX9_TCM_B04A_RAWConfirmed
- Service 22
DID B04A - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B009 raw value RX9_TCM_B009_RAWConfirmed
- Service 22
DID B009 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B011 raw value RX9_TCM_B011_RAWConfirmed
- Service 22
DID B011 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x4D = 77 → 77
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B013 raw value RX9_TCM_B013_RAW
- Service 22
DID B013 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B019 raw value RX9_TCM_B019_RAWConfirmed
- Service 22
DID B019 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B025 raw value RX9_TCM_B025_RAW
- Service 22
DID B025 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B042 raw value RX9_TCM_B042_RAWConfirmed
- Service 22
DID B042 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B043 raw value RX9_TCM_B043_RAWConfirmed
- Service 22
DID B043 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B047 raw value RX9_TCM_B047_RAW
- Service 22
DID B047 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B048 raw value RX9_TCM_B048_RAWConfirmed
- Service 22
DID B048 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B049 raw value RX9_TCM_B049_RAW
- Service 22
DID B049 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B052 raw value RX9_TCM_B052_RAW
- Service 22
DID B052 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B056 raw value RX9_TCM_B056_RAWConfirmed
- Service 22
DID B056 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x0C = 12 → 12
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module B058 raw value RX9_TCM_B058_RAW
- Service 22
DID B058 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Transmission module B059 raw value RX9_TCM_B059_RAWConfirmed
- Service 22
DID B059 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Transmission module D001 raw value RX9_TCM_D001_RAWConfirmed
- Service 22
DID D001 - Module
7E1 → 7E9 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x77 = 119 → 119
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Electrical
Control module voltage, engine module RX9_ECM_VPWR
- Service 22
DID 0112 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2026.
Control module voltage, module 7EA RX9_7EA_VPWR
- Service 22
DID 0112 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2026.
Control module voltage, transmission module RX9_TCM_VPWR
- Service 22
DID 0112 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2026.
Engine
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2025.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025.
Engine oil pressure RX9_EOPConfirmed
- Service 22
DID B036 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1500.7515 kPa
- Unit
- kPa
0x0CF5 = 3317 → = 75.9593 kPa
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine oil temperature RX9_EO_TConfirmed
- Service 22
DID B034 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
0x6A = 106 → = 31.5 °C
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2025.
Misfires, cylinder 1 RX9_MISFIRES_C1Confirmed
- Service 22
DID B143 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x010C = 268 → 268
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Misfires, cylinder 2 RX9_MISFIRES_C2Confirmed
- Service 22
DID B144 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00CB = 203 → 203
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Misfires, cylinder 3 RX9_MISFIRES_C3Confirmed
- Service 22
DID B145 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0150 = 336 → 336
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Misfires, cylinder 4 RX9_MISFIRES_C4Confirmed
- Service 22
DID B146 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00ED = 237 → 237
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2025.
Transmission fluid temperature, ECU 10472701 and 11194479 RX9_ATF_T_ECU_10472701_11194479
- Service 22
DID B423 - Module
7E1 → 7E9 - Every
1 s - Testing for 2023 to 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2024, 2026. Supported for 2025.
Transmission fluid temperature, ECU 10513229 RX9_ATF_T_ECU_10513229
- Service 22
DID 1940 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2024, 2026. Not supported for 2025.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2025.
Fuel
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025.
Fuel tank level RX9_FUEL_TANK_LEVELConfirmed
- Service 22
DID B043 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 MG RX9.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
0x0087 = 135 → = 13.5 L
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2025.
Trips
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2025.
Odometer, engine module RX9_ECM_ODO
- Service 22
DID E101 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2023 to 2026.