Mitsubishi ASX

Parameters

The Mitsubishi ASX has 208 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature ASX_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x46 = 70 → 70−40 = 30 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery temperature ASX_BAT_T

  • Service 21PID 46
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Climate

A/C compressor drive flag ASX_AC_A_C_COMPRESSOR_DRIVE_FLAGConfirmed

  • Service 21PID 70
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

A/C compressor drive request ASX_AC_A_C_COMPRESSOR_DRIVE_REQUESTConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Air conditioning switch ASX_AC_SWITCHConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Air temperature sensor ASX_AC_AIR_THERMO_SNSConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val4−16
Range
-16 to 47.75 °C
Unit
°C

0x47 = 71 → 714−16 = 1.75 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 1998, 2012, 2015.

Ambient air temperature ASX_AC_AATConfirmed

  • Service 21PID 11
  • Module688 → 511
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x48 = 72 → 722−40 = -4 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Compressor ON/OFF count ASX_AC_COMPRESSOR_ON_OFF_COUNTConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

0x00E512 = 58642 → 58,642

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Compressor work time ASX_AC_COMPRESSOR_WORK_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 128 to 151 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x015C97 = 89239 → 89239×5 = 446,195

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Conditioner work time ASX_AC_CONDITIONER_WORK_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 104 to 127 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x0461A2 = 287138 → 287138×5 = 1,435,690

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Driver side output speed ASX_AC_OUTPUT_VSS_DRConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 16
Unit
Number

0x00 = 0 → 02 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine coolant temperature ASX_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x46 = 70 → 70−40 = 30 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine RPM ASX_AC_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x05C4 = 1476 → 1,476 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fan M1 work time ASX_AC_FAN_M1_WORK_TIMEConfirmed

  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 40 to 63 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x02D6B0 = 186032 → 186032×5 = 930,160

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fan M2 work time ASX_AC_FAN_M2_WORK_TIMEConfirmed

  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 87 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x02A4EB = 173291 → 173291×5 = 866,455

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Idle up request ASX_AC_IDLE_UP_REQUESTConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 rpm
Unit
rpm

0x00 = 0 → 0 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Interior temperature ASX_AC_INTERIOR_TConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4−16
Range
-16 to 47.75 °C
Unit
°C

0x4B = 75 → 754−16 = 2.75 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Leak indicator ASX_AC_LEAK_INDICATORConfirmed

  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Leak indicator at 20% ASX_AC_LEAK_INDICATOR_20Confirmed

  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Max pressure ASX_AC_MAX_PRESConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 96 to 103 of the reply, 8 bits.

Formula
val×3.3255
Range
0 to 3.3
Unit
Raw value

0x9A = 154 → 154×3.3255 = 1.992941

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Output mode ASX_AC_OUTPUT_MODEConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 16
Unit
Number

0x00 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Passenger side output speed ASX_AC_OUTPUT_VSS_ASConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 16
Unit
Number

0x00 = 0 → 02 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Pressure ASX_AC_PRESConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3.3255
Range
0 to 3.3
Unit
Raw value

0x19 = 25 → 25×3.3255 = 0.323529

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Rear defogger ON/OFF count ASX_AC_REAR_DEFOGGER_ON_OFF_COUNTConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x009D = 157 → 157

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Recirculation time ASX_AC_RECIRCULATION_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 176 to 191 of the reply, 16 bits.

Formula
val×5
Range
0 to 327675 min
Unit
min

0x0AC4 = 2756 → 2756×5 = 13,780 min

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Solar sensor ASX_AC_SOLAR_SNSConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×5.5255
Range
0 to 5.5
Unit
Number

0x65 = 101 → 101×5.5255 = 2.178431

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

System work time ASX_AC_SYSTEM_WORK_TIMEConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 23 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x0A03DE = 656350 → 656350×5 = 3,281,750

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Vehicle speed ASX_AC_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 250 km/h
Unit
km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 1998, 2012, 2015.

Brake pedal ASX_CVT_BRAKEConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Brake switch ASX_MPI_BRAKE_SWITCHConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Normal brake closed status ASX_MPI_NORMAL_BRAKE_CLOSED_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Electrical

Dashboard voltage ASX_DASHBOARD_VConfirmed

  • Service 21PID AF
  • Module6A0 → 514
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x77 = 119 → 11910 = 11.9 V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine

A/C compressor ASX_AC_COMPRESSOR

  • Service 21PID 4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

A/C compressor relay ASX_MPI_A_C_COMPRESSOR_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Absolute load ASX_MPI_ABSOLUTE_LOADConfirmed

Pelican can show this parameter as the absolute engine load.

  • Service 21PID 1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x0E = 14 → 14×100255 = 5.490196 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2021. Supported for 1998, 2012, 2015.

Accelerator pedal closed position learning, main ASX_APS_CLOSED_LEARNConfirmed

  • Service 21PID 09
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0007629394−2.5
Range
-2.5 to 47.49 V
Unit
V

0x00D0 = 208 → 208×0.0007629394−2.5 = -2.341309 V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2021. Supported for 1998, 2010, 2015.

Air flow sensor voltage ASX_MPI_AIR_FLOW_SNS_VConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Battery voltage ASX_MPI_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×18255
Range
0 to 18 V
Unit
V

0xA2 = 162 → 162×18255 = 11.435294 V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Boost pressure ASX_BPConfirmed

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×0.19285
Range
0 to 49.17 psi
Unit
psi

0x00 = 0 → 0×0.19285 = 0 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Boost pressure ASX_BP_7E0_C4

  • Service 21PID C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×0.170636
Range
0 to 43.51 psi
Unit
psi

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Calculated load ASX_MPI_CALCULATED_LOADConfirmed

Pelican can show this parameter as the engine load.

  • Service 21PID 1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Catalyst temperature ASX_CAT_T

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Supported for 2021.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2021. Supported for 1998, 2012, 2015.

Cooling fan duty ASX_COOLING_FAN_DUTY

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cooling fan duty ASX_MPI_COOLING_FAN_DUTYConfirmed

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.3922
Range
0 to 100.011 %
Unit
%

0x00 = 0 → 0×0.3922 = 0 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Crank angle sensor ASX_MPI_CRANK_ANGLE_SNSConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 31 of the reply, 16 bits.

Formula
val8
Range
0 to 8000 rpm
Unit
rpm

0x1734 = 5940 → 59408 = 742.5 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Cranking signal ASX_MPI_CRANKING_SIG_STConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Cycle consumption ASX_CYCLE_CONS

  • Service 21PID 4A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Detonation control learned ASX_MPI_DETONATION_CTRL_LEARNEDConfirmed

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xEA = 234 → 234×100255 = 91.764706 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Detonation retard ASX_MPI_DETONATION_RETARDConfirmed

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×90255
Range
0 to 90
Unit
Number

0x00 = 0 → 0×90255 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter differential pressure ASX_DPF_DIFF_P_7E0Confirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits.

Formula
val2−10
Range
-10 to 117 kPa
Unit
kPa

0x02 = 2 → 22−10 = -9 kPa

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter soot ASX_DPF_SOOTConfirmed

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

0x00 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter soot load, summation method ASX_DPF_SOOT_SUMConfirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75
Unit
Number

0x00 = 0 → 020 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter soot pressure method, g/l ASX_DPF_SOOT_P_METHOD_G_LConfirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75
Unit
Number

0x00 = 0 → 020 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter temperature ASX_DPF_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x33 = 51 → 51×5−200 = 55 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter, maximum temperature 1 ASX_DPF_MAX_T_1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Supported for 2021.

Engine control relay ASX_MPI_ENGINE_CTRL_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine coolant temperature ASX_MPI_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x81 = 129 → 129−40 = 89 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Engine load ASX_MPI_ENGINE_LOADConfirmed

Pelican can show this parameter as the engine load.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Exhaust gas recirculation valve duty ASX_EGR_VALVE_DUTY

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2.549719531
Range
0 to 100 %
Unit
%

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation valve duty ASX_EGR_VALVE_DUTY_7E0_C3

  • Service 21PID C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2.549719531
Range
0 to 100 %
Unit
%

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas temperature ASX_EXH_GAS_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x0C = 12 → 12×5−200 = -140 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Exhaust thermistor temperature ASX_NTC_T

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Supported for 2021.

Fuel injection interval ASX_EP_P_C_O

  • Service 21PID 4B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 ms
Unit
ms

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection volume control, cylinder 1 ASX_O_E_P_C_O_O_P_1

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection volume control, cylinder 2 ASX_O_E_P_C_O_O_P_2

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel injection volume control, cylinder 3 ASX_O_E_P_C_O_O_P_3

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Idle status ASX_MPI_IDLE_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Ignition advance ASX_MPI_IGN_ADVANCEConfirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−20
Range
-20 to 235
Unit
Number

0x0B = 11 → 11−20 = -9

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Ignition switch ASX_MPI_IGN_SWITCHConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Injection qty ASX_INJECTION_QTY

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injection qty ASX_INJECTION_QTY_7E0_C2

  • Service 21PID C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2.549719531
Range
0 to 100
Unit
Raw value

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injector drive time ASX_MPI_INJECTOR_DRIVE_TIMEConfirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 ms
Unit
ms

0x00 = 0 → 04 = 0 ms

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Intake air temperature ASX_MPI_IATConfirmed

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 120 °C
Unit
°C

0x27 = 39 → 39−40 = -1 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Main accelerator position ASX_MPI_ACCELERATOR_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

0x33 = 51 → 51×5255 = 1 V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Main injection timing ASX_OE_PE_P_C

  • Service 21PID 4B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Main throttle position ASX_MPI_THROTTLE_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Manifold pressure ASX_MPI_MANIFOLD_PRESConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 126 kPa
Unit
kPa

0x1800 = 6144 → 6144512 = 12 kPa

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Neutral status ASX_MPI_NEUTRAL_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Off condition ASX_MPI_OFF_CONDConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Purge valve control ASX_MPI_PURGE_VALVE_CTRLConfirmed

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021. Supported for 1998, 2012, 2015.

Small injection quantity learning ASX_SMALL_INJ_LEARN

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Sub accelerator position ASX_MPI_ACCELERATOR_POSITION_SUBConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Sub throttle position ASX_MPI_THROTTLE_POSITION_SUBConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Target idle RPM ASX_MPI_TGT_IDLE_RPMConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×2000255
Range
0 to 2000 rpm
Unit
rpm

0x53 = 83 → 83×2000255 = 650.980392 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Target main throttle position ASX_MPI_TGT_THROTTLE_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Target throttle control ASX_MPI_TGT_THROTTLE_CTRLConfirmed

  • Service 21PID 12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 5 V
Unit
V

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Throttle control relay ASX_MPI_THROTTLE_CTRL_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Throttle control servo ASX_MPI_THROTTLE_CTRL_SERVOConfirmed

  • Service 21PID 12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Variable valve timing phase angle ASX_MPI_VVT_PHASE_ANGLEConfirmed

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val1.6−80
Range
-80 to 79.375 °
Unit
°

0x7F = 127 → 1271.6−80 = -0.625 °

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Vehicle speed ASX_MPI_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2
Range
0 to 200 km/h
Unit
km/h

0x01 = 1 → 1×2 = 2 km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2021.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2021.

Fuel

Fuel level ASX_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID A3
  • Module6A0 → 514
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−16
Range
0 to 100 %
Unit
%

0x4C = 76 → 76−16 = 60 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fuel pump relay ASX_MPI_FUEL_PUMP_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fuel rail pressure ASX_FUEL_RAIL_PRES

  • Service 21PID 4C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×145.04
Range
0 to 36985.2 psi
Unit
psi

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel rail pressure ASX_FUEL_RAIL_PRES_7E0_C2

  • Service 21PID C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×113.754872
Range
0 to 29007 psi
Unit
psi

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel rail valve duty ASX_FUEL_RAIL_VALVE_DUTY

  • Service 21PID C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2.549719531
Range
0 to 100 %
Unit
%

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel temperature ASX_FUEL_T

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel temperature ASX_FUEL_T_7E0_C2

  • Service 21PID C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Long term fuel correction ASX_MPI_LONG_TERM_FUEL_CORRECTIONConfirmed

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2051−50.196078
Range
-50.19 to 49.8 %
Unit
%

0x73 = 115 → 115×2051−50.196078 = -5.098039 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Short term fuel correction ASX_MPI_SHORT_TERM_FUEL_CORRECTIONConfirmed

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2051−50.196078
Range
-50.19 to 49.8 %
Unit
%

0x80 = 128 → 128×2051−50.196078 = 0 %

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Movement

Front left wheel speed sensor ASX_ABS_FL_VSSConfirmed

  • Service 21PID 01
  • Module784 → 785
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Front right wheel speed sensor ASX_ABS_FR_VSSConfirmed

  • Service 21PID 01
  • Module784 → 785
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Rear left wheel speed sensor ASX_ABS_RL_VSSConfirmed

  • Service 21PID 01
  • Module784 → 785
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 47 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Rear right wheel speed sensor ASX_ABS_RR_VSSConfirmed

  • Service 21PID 01
  • Module784 → 785
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 48 to 63 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2021. Supported for 1998, 2010, 2012, 2015.

Tires

Pressure front left ASX_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 23
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xA2 = 162 → 1625 = 32.4 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Pressure front right ASX_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 26
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xA1 = 161 → 1615 = 32.2 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Pressure rear left ASX_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 24
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xA6 = 166 → 1665 = 33.2 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Pressure rear right ASX_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 25
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xA4 = 164 → 1645 = 32.8 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Pressure spare tire ASX_TP_SPAREConfirmed

  • Service 21PID 27
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Temperature front left ASX_TT_FLConfirmed

Pelican can show this parameter as the front left tire temperature.

  • Service 21PID 23
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x36 = 54 → 54−50 = 4 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Temperature front right ASX_TT_FRConfirmed

Pelican can show this parameter as the front right tire temperature.

  • Service 21PID 26
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x33 = 51 → 51−50 = 1 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Temperature rear left ASX_TT_RLConfirmed

Pelican can show this parameter as the rear left tire temperature.

  • Service 21PID 24
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x31 = 49 → 49−50 = -1 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Temperature rear right ASX_TT_RRConfirmed

Pelican can show this parameter as the rear right tire temperature.

  • Service 21PID 25
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x35 = 53 → 53−50 = 3 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Temperature spare tire ASX_TT_SPAREConfirmed

  • Service 21PID 27
  • Module600 → 500
  • Every15 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Transmission

Accelerator pedal ASX_CVT_ACCELERATORConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Anti-lock brake actuator signal ASX_CVT_ABS_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Clutch 1 slip speed ASX_CLUTCH_1_SLIP_AT_VSS

  • Service 21PID A6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Clutch 1 temperature ASX_CLUTCH_1_T

  • Service 21PID A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−50
Range
-50 to 65485 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Clutch 2 temperature ASX_CLUTCH_2_T

  • Service 21PID A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val−50
Range
-50 to 65485 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Current gear ASX_AT_CUR_GEARConfirmed

  • Service 21PID 04
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x22 = 34 → 34

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Current gear ratio ASX_CURRENT_GEAR_AT_RATIOConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

0x6A = 106 → 106100 = 1.06

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Drive selected ASX_CVT_SELECTOR_DConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fluid degradation ASX_CVT_OIL_DEGRADATIONConfirmed

Pelican can show this parameter as the CVT deterioration.

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Fluid degradation, output 3 ASX_CVT_OUT3_OIL_DEGRADATIONConfirmed

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x408F = 16527 → 16,527

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Gear number ASX_CVT_GEAR_AT_NUMBERConfirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits.

Formula
val+1
Range
1 to 256
Unit
Number

0x00 = 0 → 0+1 = 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Input speed ASX_INPUT_VSSConfirmed

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 23 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

0x001E = 30 → 302 = 15 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Input torque ASX_AT_INPUT_TORQUEConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×325
Range
-819.2 to 812.8 N·m
Unit
N·m

0x00 = 0 → 0×325 = 0 N·m

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Line pressure ASX_AT_LINE_PRESConfirmed

  • Service 21PID 04
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.3255
Range
0 to 6.3
Unit
Raw value

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Lock-up solenoid monitor current ASX_CVT_LU_SOLENOID_MONITOR_MAConfirmed

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

0x0011 = 17 → 17 mA

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Lock-up solenoid output current ASX_CVT_LU_SOLENOID_OUTPUT_MAConfirmed

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

0x0000 = 0 → 0 mA

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Lock-up/select changeover solenoid monitor ASX_CVT_LU_SEL_CHANGEOVER_SOL_MONITORConfirmed

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 115 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Lock-up/select changeover solenoid output ASX_CVT_LU_SEL_CHANGEOVER_SOL_OUTPUTConfirmed

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 107 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Low selected ASX_CVT_SELECTOR_LConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Neutral selected ASX_CVT_SELECTOR_NConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Operating time ASX_CVT_TOTAL_TIMEConfirmed

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 47 of the reply, 16 bits.

Formula
val6
Range
0 to 10922.5
Unit
Raw value

0x6A82 = 27266 → 272666 = 4,544.333333

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Output speed ASX_OUTPUT_VSSConfirmed

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 39 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

0x20B4 = 8372 → 83722 = 4,186 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Paddle shift mode ASX_CVT_SELECTOR_DS_7E1_06Confirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Park selected ASX_CVT_SELECTOR_PConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Primary pressure ASX_PRIMARY_PRESConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 96 to 103 of the reply, 8 bits.

Formula
val×3.627392
Range
0 to 924 psi
Unit
psi

0x11 = 17 → 17×3.627392 = 61.665664 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Primary pressure ASX_PRIMARY_PRES_7E1_01

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×1.332854−85.26
Range
-85.26 to 254 psi
Unit
psi

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Primary pulley speed ASX_CVT_PRIMARY_VSSConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32−64
Range
-64 to 8096 rpm
Unit
rpm

0x00 = 0 → 0×32−64 = -64 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Real engine torque ASX_AT_REAL_ENGINE_TORQUEConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×325
Range
-819.2 to 812.8 N·m
Unit
N·m

0x00 = 0 → 0×325 = 0 N·m

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Reverse selected ASX_CVT_SELECTOR_RConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Secondary pressure ASX_SECONDARY_PRESConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 88 to 95 of the reply, 8 bits.

Formula
val×3.627392
Range
0 to 924 psi
Unit
psi

0x19 = 25 → 25×3.627392 = 90.6848 psi

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Secondary pulley speed ASX_CVT_SECONDARY_VSSConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×64−128
Range
-128 to 16192 rpm
Unit
rpm

0x00 = 0 → 0×64−128 = -128 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Sleep revolution ASX_AT_SLEEP_REVOLUTIONConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 rpm
Unit
rpm

0x0F = 15 → 15 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Slip speed ASX_SLIP_AT_VSSConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 rpm
Unit
rpm

0x7F = 127 → 127 rpm

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Slip speed ASX_SLIP_AT_VSS_7E1_02

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Bits 64 to 71 of the reply, 8 bits.

Formula
val−51
Range
-51 to 204 rpm
Unit
rpm

In testing for 1998, 2010 to 2020, 2022 to 2026. Supported for 2021.

Sport mode selected ASX_CVT_SELECTOR_DSConfirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Stability control actuator signal ASX_CVT_ASC_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Target gear ratio ASX_TARGET_GEAR_AT_RATIOConfirmed

  • Service 21PID 04
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

0x38 = 56 → 56100 = 0.56

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Torque ratio ASX_AT_TORQUE_RATIOConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 64 to 71 of the reply, 8 bits.

Formula
val×3.98255
Range
0 to 3.98
Unit
Number

0x00 = 0 → 0×3.98255 = 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Traction control actuator signal ASX_CVT_TCL_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Transmission fluid temperature ASX_AT_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

0xFC = 252 → 252−55 = 197 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Transmission fluid temperature ASX_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x97 = 151 → 151−40 = 111 °C

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Transmission temperature ASX_T_M_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 33
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 1998, 2010 to 2020, 2022 to 2026. Not supported for 2021.

Transmission temperature sensor count ASX_CVT_T_RAWConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x86 = 134 → 134

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Trips

Diesel particulate filter odometer ASX_DPF_ODOConfirmed

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x001200 = 4608 → 4,608 km

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Diesel particulate filter soot accumulation for distance 1 ASX_DPF_SOOT_1Confirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 km
Unit
km

0x00 = 0 → 0×10 = 0 km

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Mileage before servicing ASX_MILEAGE_BEFORE_SERVICINGConfirmed

  • Service 21PID BC
  • Module6A0 → 514
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 km
Unit
km

0x42 = 66 → 66×100 = 6,600 km

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Months before servicing ASX_PERIOD_BEFORE_SERVICING_MONTHSConfirmed

  • Service 21PID BC
  • Module6A0 → 514
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x1B = 27 → 27

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Odometer ASX_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 21PID AD
  • Module6A0 → 514
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x029A00 = 170496 → 170,496 km

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Odometer ASX_ODO_784Confirmed

  • Service 21PID 54
  • Module784 → 785
  • Every30 s
  • Testing for 1998, 2010 to 2020, 2022 to 2026

Example reply from a 2021 Mitsubishi ASX.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×1285
Range
0 to 1677696 km
Unit
km

0x1A35 = 6709 → 6709×1285 = 171,750.4 km

Confirmed for 2021. In testing for 1998, 2010 to 2020, 2022 to 2026.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.