Peugeot 408

Parameters

The Peugeot 408 has 286 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator pedal signal 1 voltage P408_ACCEL_PEDAL_SIG_1_V

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal signal 1 voltage P408_ACCEL_PEDAL_SIG_1_V

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2026.

Accelerator pedal signal 2 voltage P408_ACCEL_PEDAL_SIG_2_V

  • Service 22DID D406
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2026.

Approximate position of turbocharger actuator P408_APPROXIMATE_POS

  • Service 22DID D4EC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2010 to 2026.

Battery current P408_BAT_CURRENT

  • Service 22DID D497
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
-2097152 to 2097151 A
Unit
A

In testing for 2010 to 2026.

Centralized voltage maintenance device temperature limiter state P408_CENTRALIZED_V_T

  • Service 22DID D759
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Computer power supply voltage P408_COMPUTER_POWER_SUP_V

  • Service 22DID D551
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2010 to 2026.

Energy accumulator discharge permission state P408_ENERGY_ACCUMULATOR

  • Service 22DID D74F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine control computer supply voltage P408_ENG_CTRL_COMPUTER_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 V
Unit
V

In testing for 2010 to 2026.

Engine oil level sensor voltage P408_ENG_OIL_LEVEL_SENS_V

  • Service 22DID D41E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2010 to 2026.

Evaluation of the total resistance of the voltage maintaining device P408_EVALUATION_TOT_RES_V

  • Service 22DID D72D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128040.9703
Range
0 to 0.511
Unit
Number

In testing for 2010 to 2026.

Minimum battery voltage at startup P408_MIN_BAT_V_STARTUP

  • Service 22DID D4D4
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50.00000112
Range
-655 to 655 V
Unit
V

In testing for 2010 to 2026.

Reversible generator voltage P408_REVERSIBLE_GEN_V

  • Service 22DID D713
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2010 to 2026.

Service battery charge state P408_SERVICE_BAT_CHG_ST

  • Service 22DID D742
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Service battery charge status P408_SERVICE_BAT_CHG_STAT

  • Service 22DID D467
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2026.

Service battery temperature P408_SERVICE_BAT_T_6A8

  • Service 22DID D496
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2026.

Service battery voltage P408_SERVICE_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2010 to 2026.

Service battery wear condition P408_SERVICE_BAT_WEAR

  • Service 22DID D741
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Set voltage of energy storage P408_SET_V_ENERGY_STORAGE

  • Service 22DID D734
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2026.

Set voltage of storage battery charging P408_SET_V_STORAGE_BAT

  • Service 22DID D766
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2010 to 2026.

Set voltage of the reversible generator P408_SET_V_REVERSIBLE_GEN

  • Service 22DID D712
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val39.9999994+10.60000038
Range
0 to 16.97 V
Unit
V

In testing for 2010 to 2026.

Stop permitted by voltage maintainer computer P408_STOP_PERMITTED_V

  • Service 22DID D749
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Temperature of the electronic power unit of the voltage maintenance device P408_T_ELECTRONIC_POWER_V

  • Service 22DID D730
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2026.

Turbocharger control duty cycle P408_TURBOCHARGER_CTRL

  • Service 22DID D48A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127 %
Unit
%

In testing for 2010 to 2026.

Turbocharger first electronic boost P408_TURBOCHARGER_FIRST

  • Service 22DID D48C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Turbocharger position information P408_TURBOCHARGER_POS

  • Service 22DID D4EA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 %
Unit
%

In testing for 2010 to 2026.

Turbocharger pressure measured P408_TURBOCHARGER_P_MEAS

  • Service 22DID D4D9
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2026.

Turbocharger pressure reference P408_TURBOCHARGER_P

  • Service 22DID D556
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2026.

Turbocharger, target position P408_TURBOCHARGER_TGT_POS

  • Service 22DID D47B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2026.

Voltage at the terminals of the energy accumulator P408_V_TERMINALS_ENERGY

  • Service 22DID D720
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2026.

Voltage maintainer computer request sent P408_V_MAINTAINER_COMPUTER_REQ

  • Service 22DID D748
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Voltage maintainer computer restart permission P408_V_MAINTAINER

  • Service 22DID D747
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Voltage maintainer status P408_V_MAINTAINER_STAT

  • Service 22DID D72C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Control

Anti-lock brake or stability control regulating P408_ABS_EKS_PROCESS_ADJ

  • Service 22DID D474
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Brake circuit pressure P408_BRAKE_CIRCUIT_P

  • Service 22DID D70E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498 bar
Unit
bar

In testing for 2010 to 2026.

Brake system backup contactor status P408_BRAKE_SYSTEM_BACKUP

  • Service 22DID D463
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Main brake contactor status P408_MAIN_BRAKE_CONTACTOR

  • Service 22DID D513
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Secondary brake contactor status P408_SECONDARY_BRAKE

  • Service 22DID D514
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Vacuum present in the brake system P408_VACUUM_PRESENT_BRAKE

  • Service 22DID D700
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine

5V power supply state number 1 P408_5V_POWER_SUP_ST_1

  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

5V power supply state number 2 P408_5V_POWER_SUP_ST_2

  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

5V power supply state number 3 P408_5V_POWER_SUP_ST_3

  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

5V power supply state number 4 P408_5V_POWER_SUP_ST_4

  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

12V network allowed stop P408_12V_NETWORK_ALLOWED

  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Activation count, brake electromagnetic valve B1 P408_NUM_ACTIVATIONS_B1

  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, line pressure control solenoid P408_NUM_LINE_P_CTRL

  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, the electromagnetic valve of brake B2 P408_NUM_ACTIVATIONS_B2

  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Actual oil pressure P408_ACT_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 bar
Unit
bar

In testing for 2010 to 2026.

Additional heater control 1 P408_ADDITIONAL_HEATER_1

  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Air conditioning P408_AC

  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Air conditioning compressor current P408_AC_COMP_CURRENT

  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375
Unit
Number

In testing for 2010 to 2026.

Air conditioning pressure P408_AC_P

  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2026.

Air flow P408_AIR_FLOW

  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2026.

Air flow target P408_AIR_FLOW_TGT

  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2026.

Air temperature by air flow meter P408_AIR_T_AIR_FLOW_METER

  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Alternator load value P408_ALTERNATOR_LOAD

  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2026.

Ambient air temperature P408_AAT_6A9

  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2010 to 2026.

ANTI START PROGRAMMING STATUS P408_ANTI_START

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Atmospheric pressure P408_ATMOSPHERIC_P

  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2026.

Automatic restart request from body control module P408_AUTOMATIC_RESTART_REQ_BSI

  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic restart request from engine management computer P408_AUTOMATIC_RESTART

  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic stop allowed by body control module P408_AUTOMATIC_STOP

  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic stop allowed by power steering computer P408_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Auxiliary heater 2 control P408_AUXILIARY_HEATER_2

  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Boost air temperature P408_BOOST_AIR_T

  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Button state P408_BUTTON_ST

  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Camshaft/crankshaft position synchronization P408_CAM_CRANK_POS

  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

CHANGE REPORT IN PROGRESS P408_CHANGE_REPORT

  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Combustion engine state P408_ICE_ST

  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Commanded oil pressure P408_CMD_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2010 to 2026.

Computer lock P408_COMPUTER_LOCK

  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Computer remote wake-up state P408_COMPUTER_WAKE_UP_ST

  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Computer restarts since memory erase P408_CNT_NUM_RE

  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2026.

Computer temperature P408_COMPUTER_T

  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2026.

Control current of electromagnetic valve for changing the pressure in the brake system B2 P408_CTRL_CURRENT_P_B2

  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 P408_CTRL_CURRENT_P_B1

  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Coolant temperature P408_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Coolant temperature target P408_ECT_TGT

  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2026.

Coolant temperature, corrected P408_ECT_CORRECTED

  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2026.

Cruise control, RW status P408_CRUISE_CTRL_RW_STAT

  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Date P408_DATE

  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2026.

Driver presence P408_DRIVER_PRESENCE

  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Driver, requested torque value P408_DRIVER_REQ_TQ

  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2026.

Economy mode off state P408_ECO_MODE_OFF_ST

  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Electric cooling fan control P408_GMV_ELEC_COOLING_FAN

  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Energy accumulator state transfer P408_ENERGY_ACCUMULATOR_ST

  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Energy accumulator temperature limiter state P408_ENERGY_ACCUMULATOR_T

  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine control module status P408_ENG_CTRL_MODULE_STAT

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine coolant temperature P408_ECT_6A9

  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2026.

Engine operating mode P408_ENG_OP_MODE

  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2010 to 2026.

Engine restart counter P408_ENG_RESTART_CNT

  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Engine restart counter by stop and start function P408_ENG_RESTART_CNT_STOP

  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Engine restart request sent by ESP computer P408_ENG_RESTART_REQ_SENT

  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine stalls P408_ENG_STALLS

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine start prohibition control, start lock P408_ENG_START

  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engine stop time P408_ENG_STOP_TIME

  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2010 to 2026.

Engine torque P408_ENG_TQ

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2026.

Estimated torque of internal friction of the engine P408_ESTIMATED_TQ

  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2026.

Expected generator supplier identifier of the reversible generator P408_EXPECTED_GEN

  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Expected identifier of electronic power circuit of reversible generator generator P408_EXPECTED_IDENTIFIER_ELECTRONIC

  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Expected identifier of reversible generator P408_EXPECTED_IDENTIFIER

  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

FUGITIVE TRIP IN EMERGENCY MODE P408_FUGITIVE_TRIP

  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Generator mode P408_GEN_MODE

  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75
Range
0 to 19125 rpm
Unit
rpm

In testing for 2010 to 2026.

Generator shutdown P408_GEN_SHUTDOWN

  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Identifier of the electronic power circuit of the reversible generator P408_IDENTIFIER

  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Identifier of the supplier of the reversible generator P408_IDENTIFIER_SUPPLIER

  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Immobilizer code programming status P408_IMMOBILIZER_CODE

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Indicated engine torque P408_INDICATED_ENG_TQ

  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2026.

Line pressure solenoid valve control current P408_SLT_LINE_P_VARIATION

  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Lock status P408_LOCK_STAT

  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Maximum allowable torque P408_MAX_ALLOWABLE_TQ

  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2026.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 P408_MEAS_CURRENT_P_B2

  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 P408_MEAS_CURRENT_P_B1

  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured line pressure variation solenoid valve current P408_MEAS_LINE_P

  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Mileage since last oil change P408_MILEAGE_SINCE_OIL

  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2010 to 2026.

Neutral position sensor status P408_NEUTRAL_POS_SENS

  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Number of engine stop information deletion cycles P408_NUM_ENG_STOP

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Oil pressure P408_OIL_P

  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2026.

Oil pressure reference value P408_OIL_P_REFERENCE

  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2026.

Oil pressure regulation control P408_OIL_P_REGULATION

  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2010 to 2026.

Oil temperature P408_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Outside air temperature P408_AAT_6A8

  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2026.

Powertrain condition P408_POWERTRAIN_COND

  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Presence of the identifier of the reversible generator P408_PRESENCE_IDENTIFIER

  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Problems detected while transmitting unlock code P408_PROBLEMS_DETECTED

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Problems detected while transmitting unlock code P408_PROBLEMS_DETECTED_WHILE

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Real engine torque P408_REAL_ENG_TQ

  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2026.

Remote wake-up circuit status P408_REMOTE_WAKE_UP

  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Remote wake-up state P408_REMOTE_WAKE_UP_ST

  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Request to turn on the engine diagnostic indicator P408_REQ_TURN_ON_ENG

  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Requested value controlled thermostat P408_REQ_CONTROLLED

  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2026.

Restart request sent by power steering computer P408_RESTART_REQ_SENT

  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Restart request sent by suspension computer P408_RESTART_REQ_SENT_SUSPENSION

  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Return to engine start and restart control by starter P408_RETURN_ENG_START

  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Return to starter engine restart control P408_RETURN_STARTER_ENG

  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Reverse generator status P408_REVERSE_GEN_STAT

  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Reversible generator torque P408_REVERSIBLE_GEN_TQ

  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2026.

Service network related engine restart request P408_SERVICE_NETWORK

  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Sport mode contactor state P408_SPORT_MODE_CONTACTOR

  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Start inhibit control, wired P408_START_INHIBIT_CTRL

  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Start or restart inhibition transmitted by engine management computer P408_START_OR_RESTART

  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Start prohibition P408_START_PROHIBITION

  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Starter activation counter P408_STARTER_ACTIVATION

  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Starter control interface unit operating status P408_STARTER_CTRL

  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Starter duty cycle P408_STARTER_DUTY

  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2010 to 2026.

Starter engagement status P408_STARTER_ENGAGEMENT

  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

State lock/unlock control unit P408_ST_LOCK_UNLOCK_CTRL

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Status of internal ignition motor P408_STAT_INTERNAL_IGN

  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Status of the energy accumulator P408_STAT_ENERGY

  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2026.

Stop allowed by ESP computer P408_STOP_ALLOWED_ESP

  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Stop and start function state P408_STOP_START_FUNCTION

  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Stop and start switch P408_STOP_START_SWITCH

  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Stop permitted by suspension computer P408_STOP_PERMITTED

  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Temperature of the energy accumulator P408_T_ENERGY_ACCUMULATOR

  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2026.

The composition of the mixture is calculated by the oxygen sensor P408_COMPOSITION_MIXTURE

  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2026.

Torque corresponding to driver requirement P408_TQ_CORRESPONDING

  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2026.

Torque supplied or taken by generator P408_TQ_SUPPLIED_OR_TAKEN

  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2026.

Total mileage P408_ODO_6A8

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2010 to 2026.

Towing device configured P408_CAN_VEH_BE_EQUIPPED

  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Traction or stability control regulating P408_ASR_OR_ESP_SYSTEM

  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Transmission fluid temperature P408_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2010 to 2026.

Vacuum circuit vacuum P408_VACUUM_CIRCUIT

  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2026.

Value during generator load smooth increase P408_DURING_GEN_LOAD

  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Vehicle hour meter P408_VEH_HOUR_METER

  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2026.

Vehicle mileage since the last oil change under severe vehicle operating conditions P408_VEH_MILEAGE_SINCE

  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2010 to 2026.

Winter mode switch state P408_WINTER_MODE_SWITCH

  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Fuel

Fuel pressure P408_FUEL_P

  • Service 22DID D41F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val999.9999525
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2010 to 2026.

Fuel temperature P408_FUEL_T

  • Service 22DID D42A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2026.

High fuel pressure measured P408_HIGH_FUEL_P_MEAS

  • Service 22DID D446
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2010 to 2026.

Low pressure fuel pump actuator duty cycle P408_LOW_P_FUEL_PMP

  • Service 22DID D472
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2026.

Low pressure fuel pump status P408_LOW_P_FUEL_PMP_STAT

  • Service 22DID D4ED
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Minimum fuel level P408_MIN_FLI

  • Service 22DID D56A
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Movement

Accelerator pedal position P408_ACCEL_PEDAL_POS

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×39100
Range
0 to 99.45 %
Unit
%

In testing for 2010 to 2026.

Accelerator pedal position P408_ACCEL_PEDAL_POS_6A9

  • Service 22DID D505
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2010 to 2026.

Accelerator pedal position, recalculated P408_ACCEL_PEDAL_POS_RECALCULATED

  • Service 22DID D407
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2010 to 2026.

Accelerator pedal position, track 1 P408_ACCEL_PEDAL_POS_1

  • Service 22DID D491
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2026.

Accelerator pedal position, track 2 P408_ACCEL_PEDAL_POS_2

  • Service 22DID D492
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2026.

Clutch release state at stop, creep speed reduction P408_CLU_RELEASE_ST_STOP

  • Service 22DID D672
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Crankshaft speed P408_CRANK_SPD

  • Service 22DID D462
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2010 to 2026.

Crankshaft speed determined by camshaft sensor P408_CRANK_SPD_DETERMINED

  • Service 22DID D499
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2010 to 2026.

Cruise control set speed P408_CRUISE_CTRL_SET_SPD

  • Service 22DID D475
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2026.

Engine RPM P408_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID D400
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2010 to 2026.

Engine RPM P408_RPM_6A9

Pelican can show this parameter as the engine speed.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2010 to 2026.

Input shaft speed P408_INPUT_SHFT_SPD

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2010 to 2026.

Set speed of electric cooling fan P408_SET_SPD_ELEC_COOLING

  • Service 22DID D4AA
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2026.

STATUS COMMANDS REGULATION OR LIMITATION SPEED P408_STAT_COMMANDS

  • Service 22DID D704
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Torque converter slip speed, measured P408_TQ_CONV_SLIP_SPD

  • Service 22DID D654
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2010 to 2026.

Vehicle speed P408_VSS

Pelican can show this parameter as the speed.

  • Service 21PID C8
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2026.

Vehicle speed P408_VSS_6A8

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 km/h
Unit
km/h

In testing for 2010 to 2026.

Vehicle speed P408_VSS_6A9

Pelican can show this parameter as the speed.

  • Service 22DID D711
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2026.

Vehicle speed limiter set speed P408_VSS_LIMITER_SET_SPD

  • Service 22DID D476
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2026.

Vehicle speed limiter status, LW P408_VSS_LIMITER_STAT_LW

  • Service 22DID D4C0
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Tires

Average front wheel speed P408_AVG_FRONT_WHL_SPD

  • Service 22DID D530
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val25.00000056
Range
0 to 2621 rpm
Unit
rpm

In testing for 2010 to 2026.

Average speed front wheels P408_AVG_SPD_FRONT_WHEELS

  • Service 22DID D533
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2026.

Counter of occurrence of enhanced resonance of the twin flywheel of the engine P408_CNT_OCCURRENCE

  • Service 22DID D4E4
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2026.

Counter of occurrence of resonance of the twin flywheel of the engine P408_CNT_OCCURRENCE_RESONANCE

  • Service 22DID D4E5
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2026.

Rear left wheel speed P408_RL_WHL_SPD

  • Service 22DID D531
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2026.

Rear right wheel speed P408_RR_WHL_SPD

  • Service 22DID D532
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2026.

Transmission

Activation count, additional oil pump, ATN8 gearbox P408_NUM_ADDITIONAL_OIL

  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, clutch electromagnetic valve C2 P408_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2

  • Service 22DID D743
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, clutch electromagnetic valve C3 P408_NUM_ACTIVATIONS_CLU_C3

  • Service 22DID D744
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, clutch protection C1 P408_NUM_ACTIVATIONS_CLU_C1

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Activation count, clutch protection C2 P408_NUM_ACTIVATIONS_CLU_C2

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Activation count, gear 7 P408_NUM_ACTIVATIONS_GEAR_7

  • Service 22DID D75B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, shift solenoid SC2 P408_NUM_SHIFT_SOLENOID

  • Service 22DID D752
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, shift solenoid SC3 P408_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3

  • Service 22DID D753
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p P408_NUM_ACTIVATIONS_P

  • Service 22DID D758
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, the electromagnetic valve of clutch C4 P408_NUM_ACTIVATIONS_C4

  • Service 22DID D759
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, the electromagnetic valve of the clutch C1 P408_NUM_ACTIVATIONS_C1

  • Service 22DID D742
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation count, torque converter lockup electromagnetic valve P408_NUM_ACTIVATIONS_TQ

  • Service 22DID D746
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Activation of additional oil pump, ATN8 gearbox P408_ACTIVATION

  • Service 22DID D616
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2026.

Additional oil pump control status, atn8 transmission P408_ADDITIONAL_OIL_PMP

  • Service 22DID D617
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic restart request from transmission computer P408_AUTOMATIC_RESTART_REQ

  • Service 22DID D70B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic stop allowed by gearbox computer P408_AUTOMATIC_STOP_ALLOWED

  • Service 22DID D704
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission fluid temperature P408_AUTOMATIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2026.

Automatic transmission in emergency mode P408_AUTOMATIC_TRANS_EMERGENCY

  • Service 22DID D670
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission in park position P408_AUTOMATIC_TRANS_PARK

  • Service 22DID D70B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission input shaft mode, calculated P408_AUTOMATIC_TRANS_INPUT_SHFT_MODE

  • Service 22DID D651
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2026.

Automatic transmission input shaft mode, measured P408_AUTOMATIC_TRANS_INPUT_SHFT

  • Service 22DID D650
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2026.

Automatic transmission lubrication solenoid control current P408_AUTOMATIC_TRANS_LUBRICATION

  • Service 22DID D61A
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission oil aging sensor P408_AUTOMATIC_TRANS_OIL

  • Service 22DID D405
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Automatic transmission oil drain P408_DRAIN_TRANS

  • Service 22DID D509
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission output shaft mode, calculated P408_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE

  • Service 22DID D653
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64−8128
Range
-8128 to 4186112 rpm
Unit
rpm

In testing for 2010 to 2026.

Automatic transmission output shaft mode, measured P408_AUTOMATIC_TRANS_OUTPUT

  • Service 22DID D652
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2010 to 2026.

Automatic transmission overheat indicator request P408_AUTOMATIC_TRANS

  • Service 22DID D510
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Automatic transmission torque request P408_AUTOMATIC_TRANS_TQ

  • Service 22DID D508
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2026.

Calculated gear in gearbox P408_CALC_GEAR_GEARBOX

  • Service 22DID D409
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Clutch pedal P408_CLU_PEDAL

  • Service 22DID D404
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Clutch pedal position value P408_CLU_PEDAL_POS

  • Service 22DID D469
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2026.

Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox P408_CTRL_CURRENT_P_P

  • Service 22DID D625
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p P408_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P

  • Service 22DID D61E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Control current of electromagnetic valve of change of pressure of torque converter lock-up P408_CTRL_CURRENT_P

  • Service 22DID D61C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Control current of the electromagnetic valve for changing the gear shift SC2 P408_CTRL_CURRENT

  • Service 22DID D60A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Control current of the electromagnetic valve of change of pressure of clutch C3 P408_CTRL_CURRENT_P_C3

  • Service 22DID D614
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Control current of the electromagnetic valve of change of pressure of clutch C4 P408_CTRL_CURRENT_P_C4

  • Service 22DID D620
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Control current of the solenoid valve for changing the pressure of the clutch C1 P408_CTRL_CURRENT_P_C1

  • Service 22DID D610
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Control current of the solenoid valve for changing the pressure of the clutch C2 P408_CTRL_CURRENT_P_C2

  • Service 22DID D612
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Engaged gear P408_ENGAGED_GEAR

  • Service 22DID D43D
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Engaged gear P408_ENGAGED_GEAR_6A9

  • Service 22DID D501
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Exhaust gas temperature after upstream catalytic converter P408_EXH_GAS_T_AFTER_PRE

  • Service 22DID D555
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Exhaust gas temperature before upstream catalytic converter P408_EXH_GAS_T_BEFORE_PRE

  • Service 22DID D52E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2026.

Gear in the process of engaging P408_GEAR_PROCESS

  • Service 22DID D43E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Gear shift knob under steering wheel P408_GEAR_SHIFT_KNOB

  • Service 22DID D520
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Gear shift lever position displayed on instrument panel P408_GEAR_SHIFT_LEVER_POS_ON

  • Service 22DID D500
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Maximum clutch travel during gear shift P408_MAX_CLU_TRAVEL

  • Service 22DID D498
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2026.

Measured current of control of electromagnetic valve of automatic transmission lubrication P408_MEAS_CURRENT_CTRL

  • Service 22DID D61B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up P408_MEAS_CURRENT_CTRL_P

  • Service 22DID D61D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Measured current of the electromagnetic valve for changing the gear shift SC2 P408_MEAS_CURRENT

  • Service 22DID D60B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox P408_MEAS_CURRENT_P_P

  • Service 22DID D626
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Measured current of the electromagnetic valve of change of pressure of clutch C3 P408_MEAS_CURRENT_P_C3

  • Service 22DID D615
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the electromagnetic valve of change of pressure of clutch C4 P408_MEAS_CURRENT_P_C4

  • Service 22DID D621
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the solenoid valve for changing the pressure of the clutch C1 P408_MEAS_CURRENT_P_C1

  • Service 22DID D611
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the solenoid valve for changing the pressure of the clutch C2 P408_MEAS_CURRENT_P_C2

  • Service 22DID D613
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p P408_MEAS_CURRENT_P

  • Service 22DID D61F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox P408_NUM_ENGAGEMENTS_P_P

  • Service 22DID D75D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 1 P408_NUM_GEAR_ENGAGEMENTS_1

  • Service 22DID D747
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 2 P408_NUM_GEAR_ENGAGEMENTS_2

  • Service 22DID D748
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 3 P408_NUM_GEAR_ENGAGEMENTS_3

  • Service 22DID D749
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 4 P408_NUM_GEAR_ENGAGEMENTS_4

  • Service 22DID D74A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 5 P408_NUM_GEAR_ENGAGEMENTS_5

  • Service 22DID D74B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 6 P408_NUM_GEAR_ENGAGEMENTS_6

  • Service 22DID D74C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements 8 P408_NUM_GEAR_ENGAGEMENTS_8

  • Service 22DID D75C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements n P408_NUM_GEAR_ENGAGEMENTS_N

  • Service 22DID D74E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of gear engagements right P408_NUM_GEAR_ENGAGEMENTS

  • Service 22DID D74D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of shift solenoid operated automatic transmission lubrication control valve P408_NUM_SHIFT_SOLENOID_OPERATED

  • Service 22DID D756
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of shift solenoid operated SC4 P408_NUM_SHIFT_SOLENOID_OPERATED_SC4

  • Service 22DID D754
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of shift solenoid operated SC5 P408_NUM_SHIFT_SOLENOID_OPERATED_SC5

  • Service 22DID D755
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Number of shift solenoid operated torque converter lock-up pressure regulating valve P408_NUM_SHIFT_SOLENOID_P

  • Service 22DID D757
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2026.

Operating mode used by the automatic transmission P408_OP_MODE_USED

  • Service 22DID D673
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Position of the gearshift lever P408_POS_GEARSHIFT_LEVER

  • Service 22DID D700
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Proportional clutch pedal sensor P408_PROPORTIONAL_CLU

  • Service 22DID D56E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Reverse gear contactor status P408_REVERSE_GEAR

  • Service 22DID D43C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

SC5 shift solenoid control current P408_SC5_SHIFT_SOLENOID

  • Service 22DID D618
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

SC5 shift solenoid measured current P408_SC5_SHIFT_SOLENOID_MEAS

  • Service 22DID D619
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Shift solenoid control current SC3 P408_SHIFT_SOLENOID_CTRL

  • Service 22DID D60C
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Shift solenoid control current SC4 P408_SHIFT_SOLENOID_CTRL_CURRENT_SC4

  • Service 22DID D60E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Shift solenoid measured current SC3 P408_SHIFT_SOLENOID_MEAS

  • Service 22DID D60D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Shift solenoid measured current SC4 P408_SHIFT_SOLENOID_MEAS_CURRENT_SC4

  • Service 22DID D60F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Shift-lock control P408_SHIFT_LOCK_CTRL

  • Service 22DID D701
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Start permission from gearbox computer P408_START_PERMISSION

  • Service 22DID D41A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Torque converter lock-up pressure variation solenoid valve control current P408_TQ_CONV_LOCK_UP_P

  • Service 22DID D604
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Torque converter lock-up pressure variation solenoid valve control current P408_TQ_CONV_LOCK_UP_P_VARIATION

  • Service 22DID D605
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2026.

Torque converter slip mode, theoretical value P408_TQ_CONV_SLIP_MODE

  • Service 22DID D655
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2010 to 2026.

Torque converter status P408_TQ_CONV_STAT

  • Service 22DID D504
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2026.

Upstream catalytic converter aging P408_PRE_CATALYTIC_CONV

  • Service 22DID D559
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2026.

Trips

Distance to next oil change P408_DIST_NEXT_OIL_CHANGE

  • Service 22DID D536
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2010 to 2026.

Odometer P408_ODO_6A9

Pelican can show this parameter as the odometer.

  • Service 22DID D802
  • Module6A9 → 689
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.