Porsche Macan Electric

Parameters

The Porsche Macan Electric has 84 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Front left tire pressure MACANEV_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 18A1
  • Module70B → 775
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

0x76 = 118 → 11840 = 2.95 bar

Confirmed for 2024 to 2025. In testing for 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity MACANEV_AUX_BAT_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

0x44 = 68 → 68 Ah

Confirmed for 2024 to 2025. In testing for 2026.

12V battery aging by capacity MACANEV_AUX_BAT_AGE_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x59 = 89 → 89 %

Confirmed for 2024 to 2025. In testing for 2026.

12V battery aging by power MACANEV_AUX_BAT_AGE_POWConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x59 = 89 → 89 %

Confirmed for 2024 to 2025. In testing for 2026.

12V battery current MACANEV_AUX_BAT_CConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val×0.001
Range
-1000000 to 1000000 A
Unit
A

0x000002E0 = 736 → 736×0.001 = 0.736 A

Confirmed for 2024 to 2025. In testing for 2026.

12V battery sensor temperature MACANEV_AUX_BAT_T_SConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3E = 62 → 62−40 = 22 °C

Confirmed for 2024 to 2025. In testing for 2026.

12V battery soc MACANEV_AUX_BAT_SOCConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2024 to 2025. In testing for 2026.

12V battery temperature MACANEV_AUX_BAT_TConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3D = 61 → 61−40 = 21 °C

Confirmed for 2024 to 2025. In testing for 2026.

12V battery total charge MACANEV_AUX_BAT_CHRG_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x00001124 = 4388 → 438810 = 438.8 Ah

Confirmed for 2024 to 2025. In testing for 2026.

12V battery total discharge MACANEV_AUX_BAT_DSCH_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x0000106F = 4207 → 420710 = 420.7 Ah

Confirmed for 2024 to 2025. In testing for 2026.

12V battery voltage MACANEV_AUX_BAT_VConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x264E = 9806 → 98061000+4 = 13.806 V

Confirmed for 2024 to 2025. In testing for 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2025. Supported for 2024.

HV battery capacity MACANEV_HVBAT_CAPConfirmed

Total possible energy in the high voltage battery

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0766 = 1894 → 1894×50 = 94,700 W

Confirmed for 2024 to 2025. In testing for 2026.

HV battery energy MACANEV_HVBAT_KWHConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×25
Range
0 to 1000000 W
Unit
W

0x02EB = 747 → 747×25 = 18,675 W

Confirmed for 2024 to 2025. In testing for 2026.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2024.

Control Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2024.

DTCs

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2025. Supported for 2024.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2025. Supported for 2024.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. Supported for 2024.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2025. Supported for 2024.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2025. Supported for 2024.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2024.

Engine

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2024.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2025. Supported for 2024.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. Supported for 2024.

Stats

Crashes, driver side MACANEV_CRASH_CNT_DRVRConfirmed

  • Service 22DID 2354
  • Module715 → 77F
  • Every3600 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2026.

Crashes, front MACANEV_CRASH_CNT_FRONTConfirmed

  • Service 22DID 2353
  • Module715 → 77F
  • Every3600 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2026.

Crashes, passenger side MACANEV_CRASH_CNT_PSNGRConfirmed

  • Service 22DID 2355
  • Module715 → 77F
  • Every3600 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2026.

Crashes, rear MACANEV_CRASH_CNT_REARConfirmed

  • Service 22DID 2356
  • Module715 → 77F
  • Every3600 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2026.

Crashes, rollover MACANEV_CRASH_CNT_ROLLConfirmed

  • Service 22DID 2357
  • Module715 → 77F
  • Every3600 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024 to 2025. In testing for 2026.

Tires

Front left tire pressure MACANEV_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 18A1
  • Module70B → 775
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

0x76 = 118 → 11840 = 2.95 bar

Confirmed for 2024 to 2025. In testing for 2026.

Front right tire pressure MACANEV_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 18A0
  • Module70B → 775
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

0x76 = 118 → 11840 = 2.95 bar

Confirmed for 2024 to 2025. In testing for 2026.

Rear left tire pressure MACANEV_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 18A2
  • Module70B → 775
  • Every5 s
  • Testing for 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

Confirmed for 2024 to 2025. In testing for 2026.

Rear right tire pressure MACANEV_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 18A3
  • Module70B → 775
  • Every5 s
  • Testing for 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

Confirmed for 2024 to 2025. In testing for 2026.

Trips

Average consumption (category 0) MACANEV_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B0 = 176 → 17610 = 17.6 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 1) MACANEV_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B6 = 182 → 18210 = 18.2 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 2) MACANEV_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00BF = 191 → 19110 = 19.1 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 3) MACANEV_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00C3 = 195 → 19510 = 19.5 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 4) MACANEV_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00DC = 220 → 22010 = 22 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 5) MACANEV_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B2 = 178 → 17810 = 17.8 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Average consumption (category 6) MACANEV_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2024 to 2025. In testing for 2026.

Range remaining MACANEV_RANGEConfirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Porsche Macan Electric.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x003A = 58 → 58 mi

Confirmed for 2024 to 2025. In testing for 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.