Škoda Superb

Parameters

The Škoda Superb has 3,011 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

3V supply voltage SKODA_CHRGR_3V_SUPPLY

  • Service 22DID 15F7
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100+3.1
Range
3.1 to 5.65 V
Unit
V

In testing for 2001 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

3V supply voltage SKODA_CHRGR_3V_SUPPLY

  • Service 22DID 15F7
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100+3.1
Range
3.1 to 5.65 V
Unit
V

In testing for 2001 to 2026.

12V battery adapted capacity SKODA_AUX_BAT_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

In testing for 2001 to 2026.

12V battery aging by capacity SKODA_AUX_BAT_AGE_CAP

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

12V battery aging by power SKODA_AUX_BAT_AGE_POW

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

12V battery capacity SKODA_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2001 to 2026.

12V battery current SKODA_AUX_BAT_C

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val×0.001
Range
-1000000 to 1000000 A
Unit
A

In testing for 2001 to 2026.

12V battery sensor temperature SKODA_AUX_BAT_T_S

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

12V battery soc SKODA_AUX_BAT_SOC

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

12V battery temperature SKODA_AUX_BAT_T

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

12V battery total charge SKODA_AUX_BAT_CHRG_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2001 to 2026.

12V battery total discharge SKODA_AUX_BAT_DSCH_TOT

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2001 to 2026.

12V battery voltage SKODA_AUX_BAT_V

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

In testing for 2001 to 2026.

AC charging SKODA_AC_CHARGING

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2001 to 2026.

All-wheel drive voltage SKODA_PQ35_HAL_V

  • Service 22DID 2BE9
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

All-wheel-drive pump voltage SKODA_AWD_PMP_V

  • Service 22DID 2B0E
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.84
Range
-19.84 to 19.9999 V
Unit
V

In testing for 2001 to 2026.

Aux. hydraulic pump voltage SKODA_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

Battery acid stratification SKODA_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2001 to 2026.

Battery cell soc max, ID SKODA_HVBAT_CELL_SOC_MAX_ID

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Battery cell soc min, ID SKODA_HVBAT_CELL_SOC_MIN_ID

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Battery cell soc, maximum SKODA_HVBAT_CELL_SOC_MAX

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Battery cell soc, minimum SKODA_HVBAT_CELL_SOC_MIN

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Battery condition for display SKODA_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2001 to 2026.

Battery current SKODA_BAT_I

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483 A
Unit
A

In testing for 2001 to 2026.

Battery current SKODA_MQB_BAT_I

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483.647 A
Unit
A

In testing for 2001 to 2026.

Battery current filtered SKODA_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2001 to 2026.

Battery current limit, charging SKODA_HVBAT_I_LIM_CHG

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

In testing for 2001 to 2026.

Battery current limit, discharging SKODA_HVBAT_I_LIM_DSCH

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

In testing for 2001 to 2026.

Battery current, DC, alternate SKODA_HVBAT_I_DC_2

  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100−1500
Range
-1500 to 42948172.95 A
Unit
A

In testing for 2001 to 2026.

Battery current, motor controller SKODA_HVBAT_I_ENG

  • Service 22DID 035E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2001 to 2026.

Battery heater current SKODA_HVBAT_PTC_I

  • Service 22DID 1620
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

In testing for 2001 to 2026.

Battery heater temperature, #1 SKODA_HVBAT_PTC_T_1

  • Service 22DID 1623
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Battery heater temperature, #2 SKODA_HVBAT_PTC_T_2

  • Service 22DID 1624
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Battery heater voltage SKODA_HVBAT_PTC_V

  • Service 22DID 1621
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

Battery internal resistance SKODA_BAT_INT_R

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

In testing for 2001 to 2026.

Battery internal resistance SKODA_MQB_BAT_INT_RES

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4
Unit
Raw value

In testing for 2001 to 2026.

Battery internal resistance SKODA_SSB_RES_INT

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4
Unit
Number

In testing for 2001 to 2026.

Battery internal resistance, raw SKODA_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2001 to 2026.

Battery power reduction active SKODA_BMS_PWR_REDUCE_ACT

  • Service 22DID 1E0A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Battery temperature, inlet SKODA_HVBAT_T_IN

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Battery temperature, max SKODA_HVBAT_T_MAX_V2

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Battery temperature, max sensor ID SKODA_HVBAT_T_MAX_ID

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Battery temperature, min SKODA_HVBAT_T_MIN

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Battery temperature, min sensor ID SKODA_HVBAT_T_MIN_ID

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Battery temperature, outlet SKODA_HVBAT_T_OUT

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Battery total charge SKODA_BAT_TOT_CHG

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2001 to 2026.

Battery total discharge SKODA_BAT_TOT_DIS

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2001 to 2026.

Battery voltage SKODA_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 mV
Unit
mV

In testing for 2001 to 2026.

Battery voltage SKODA_BAT_V_2A07

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

In testing for 2001 to 2026.

Battery voltage SKODA_BAT_V_PRE19

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 V
Unit
V

In testing for 2001 to 2026.

Battery voltage SKODA_BAT_V_V2

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 V
Unit
V

In testing for 2001 to 2026.

Battery voltage SKODA_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2001 to 2026.

Battery voltage SKODA_BATTERY_V_V2

  • Service 22DID 105A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

In testing for 2001 to 2026.

Battery voltage SKODA_MQB_BAT_V

  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

In testing for 2001 to 2026.

Battery voltage variant SKODA_BAT_V_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2001 to 2026.

Battery voltage variant SKODA_PQ35_BAT_V_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 20 V
Unit
V

In testing for 2001 to 2026.

Battery voltage variant SKODA_PQ35_BAT_V_2_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2001 to 2026.

Battery voltage, after main switch SKODA_HVBAT_V_AFTER

  • Service 22DID 1E38
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

In testing for 2001 to 2026.

Battery voltage, before main switch SKODA_HVBAT_V_BEFORE

  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

In testing for 2001 to 2026.

Battery voltage, charging SKODA_HVBAT_V_CHG

  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×31249978510000000000
Range
-1023.999 to 1023.967 V
Unit
V

In testing for 2001 to 2026.

Battery voltage, sum of all cells SKODA_HVBAT_V_CELLS_SUM

  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×2441406251000000000
Range
-524288 to 524287.99 V
Unit
V

In testing for 2001 to 2026.

Battery voltage, traction mode SKODA_HVBAT_V_TRAC

  • Service 22DID 4675
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 V
Unit
V

In testing for 2001 to 2026.

Boost pressure SKODA_PQ35_CHG_P

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, raw voltage SKODA_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2001 to 2026.

Calculated nitrogen oxide concentration behind turbocharger SKODA_MQB_NOX_CONC_BEHIND_TURBO

  • Service 22DID 1526
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2001 to 2026.

Cell state of charge max, index SKODA_BMS_CELL_SOC_MAX_IDX

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Cell state of charge max, value SKODA_BMS_CELL_SOC_MAX

  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Cell state of charge min, index SKODA_BMS_CELL_SOC_MIN_IDX

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Cell state of charge min, value SKODA_BMS_CELL_SOC_MIN

  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Cell voltage max, index SKODA_BMS_CELL_V_MAX_IDX

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Cell voltage max, value SKODA_BMS_CELL_V_MAX

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2001 to 2026.

Cell voltage max, value SKODA_E_TRON_BMS_CELL_V_MAX

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Cell voltage min, index SKODA_BMS_CELL_V_MIN_IDX

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Cell voltage min, value SKODA_BMS_CELL_V_MIN

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2001 to 2026.

Cell voltage min, value SKODA_E_TRON_BMS_CELL_V_MIN

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Cell voltage sum SKODA_BMS_CELL_V_SUM

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value SKODA_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2001 to 2026.

Charge air pressure SKODA_PQ35_CHG_AIR_P

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge air pressure actuator position digit.value SKODA_CHG_AIR_P_ACTUATOR

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Charge air pressure actuator, acknowledgment SKODA_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Charge air pressure, actual value SKODA_CHG_AIR_P_ACT

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Charge air pressure, actual value SKODA_CHG_AIR_P_ACT_7E0

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2001 to 2026.

Charge air pressure, specified value SKODA_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2001 to 2026.

Charge air pressure: actual SKODA_CHARGE_AIR_P_ACTUAL

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2001 to 2026.

Charge air pressure: specified SKODA_CHARGE_AIR_P_SPECIFIED

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2001 to 2026.

Charge air temp at the turbocharger outlet, calculated SKODA_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED

  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Charge limit over-charge SKODA_CHG_LIM_OVER_CHG

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Charge limit overcharge protection SKODA_PQ35_CHG_LIM_OVER

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Charge pressure actuator, actual position SKODA_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure actuator, adaptation for lower stop SKODA_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Charge pressure actuator, adaptation for upper stop SKODA_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Charge pressure actuator, maximum sensor voltage SKODA_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2001 to 2026.

Charge pressure actuator, specified position SKODA_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2001 to 2026.

Charge pressure actuator, specified value SKODA_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure before throttle valve, calculated actual value SKODA_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 2001 to 2026.

Charge pressure control adaptation higher than max. threshold SKODA_CHG_P_CTRL_ADPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control adaptation lower than min. threshold SKODA_CHG_P_CTRL_ADPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control specified value SKODA_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control valve activation pulse duty factor SKODA_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control valve position, actual value SKODA_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control valve position, target value SKODA_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Charge pressure control valve sensor voltage SKODA_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2001 to 2026.

Charge pressure control valve voltage, position closed SKODA_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2001 to 2026.

Charge pressure control valve voltage, position opened SKODA_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2001 to 2026.

Charge pressure regulator, lower threshold adaptation SKODA_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Charge pressure regulator, upper threshold adaptation SKODA_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Charge pressure sensor, unconditioned voltage SKODA_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Charge voltage, max SKODA_MAXIMUM_CHARGE_V

  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2001 to 2026.

Charger AC input current SKODA_CHG_AC_I

  • Service 22DID 1DA8
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2001 to 2026.

Charger AC input current setpoint SKODA_CHG_AC_I_SET

  • Service 22DID 15D3
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2001 to 2026.

Charger AC input voltage SKODA_CHG_AC_V

  • Service 22DID 1DA9
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2001 to 2026.

Charger coolant temperature SKODA_CHRGR_COOLANT_T

  • Service 22DID 15E2
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Charger DC to DC coil temperature SKODA_CHG_DCDC_COIL_T

  • Service 22DID 15DA
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Charger DC to DC gate driver voltage SKODA_CHG_DCDC_GATE_V

  • Service 22DID 15DD
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

Charger DC to DC power line temperature SKODA_CHG_DCDC_LINE_T

  • Service 22DID 15EC
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Charger output current SKODA_CHG_HV_I

  • Service 22DID 4237
  • Module744
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2001 to 2026.

Charger output current setpoint SKODA_CHG_HV_I_SET

  • Service 22DID 4238
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2001 to 2026.

Charger output voltage SKODA_CHG_OUT_V

  • Service 22DID 1DA7
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2001 to 2026.

Charger power factor coil temperature SKODA_CHG_PFC_COIL_T

  • Service 22DID 15D9
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Charger power factor gate driver voltage SKODA_CHG_PFC_GATE_V

  • Service 22DID 15DC
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

Charger power loss SKODA_CHG_PWR_LOSS

  • Service 22DID 15E1
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 W
Unit
W

In testing for 2001 to 2026.

Charger temperature SKODA_CHG_T

  • Service 22DID 15D8
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Charging duration total SKODA_CHRGR_DUR_TOTAL

  • Service 22DID 15EE
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2001 to 2026.

Charging efficiency SKODA_CHG_EFFICIENCY

  • Service 22DID 15D6
  • Module744
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
0 to 100.499 %
Unit
%

In testing for 2001 to 2026.

Charging, rapid? SKODA_RAPID_CHARGE_PORT

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2001 to 2026.

Control module temperature SKODA_HVBAT_ECU_T

  • Service 22DID 1622
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Control module voltage SKODA_VPWR

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2001 to 2026.

Cooling puump power set point SKODA_BMS_COOL_PUMP_PWR_SP

  • Service 22DID 192B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2001 to 2026.

Current gear SKODA_DRIVE_MODE

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

In testing for 2001 to 2026.

Cycle energy transformation SKODA_OBC_CYCLE_ENERGY

  • Service 22DID 103E
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kWh
Unit
kWh

In testing for 2001 to 2026.

Cylinder charge specified value SKODA_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Cylinder charge, actual value SKODA_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

DC battery voltage SKODA_DC_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

In testing for 2001 to 2026.

DC to DC converter circuit board temperature SKODA_DCDC_PCB_T

  • Service 22DID 464E
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

DC to DC converter high-voltage side voltage SKODA_DCDC_HV_V

  • Service 22DID 1587
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

DC to DC converter power stage temperature SKODA_DCDC_PWR_T

  • Service 22DID 464F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

DC to DC converter regulated output voltage SKODA_PE_DCDC_KL30_V

  • Service 22DID 465C
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2001 to 2026.

DC to DC converter temperature SKODA_PE_DCDC_T

  • Service 22DID 3EB5
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

DC to DC converter traction current SKODA_DCDC_HV_I

  • Service 22DID 4650
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 A
Unit
A

In testing for 2001 to 2026.

DC to DC converter traction voltage SKODA_PE_DCDC_HV_V

  • Service 22DID 465E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

DC-DC converter coolant temperature SKODA_DCDC_T_COOL

  • Service 22DID 43B8
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

DC-DC converter current, alternate SKODA_DCDC_I_ALT

  • Service 22DID 465B
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 A
Unit
A

In testing for 2001 to 2026.

DC-DC converter, current SKODA_DCDC_I

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

In testing for 2001 to 2026.

DC-DC converter, low voltage SKODA_DCDC_V_LOW

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

DC-DC converter, reserved current SKODA_DCDC_I_RSV

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

In testing for 2001 to 2026.

DC-DC voltage SKODA_DC_DC_V

  • Service 22DID 465D
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9980469 V
Unit
V

In testing for 2001 to 2026.

Diesel particulate filter charge limit for field regeneration SKODA_DPF_CHG_LIM_FIELD

  • Service 22DID 20D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter charge limit for service regeneration SKODA_DPF_CHG_LIM_SERVICE

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter charge limit over-charge SKODA_DPF_CHG_LIM_OVER_CHG

  • Service 22DID 20DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter heat voltage SKODA_DPF_HEAT_V

  • Service 22DID 44FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 V
Unit
V

In testing for 2001 to 2026.

Diesel particulate filter statistics current avg. torque gradient in charge cycle, nm/s SKODA_DPF_STATISTICS_S

  • Service 22DID 400C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics, average drive cycle time during charge cycle SKODA_DPF_STATISTICS_AVG

  • Service 22DID 4033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter statistics, average RPM in charge cycle SKODA_DPF_STATISTICS_AVG_V2

  • Service 22DID 400E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2001 to 2026.

Diesel particulate filter statistics, average temperature. after DPF in charge cycle SKODA_DPF_STATISTICS_AVG_T

  • Service 22DID 4017
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter statistics, avg drive cycle time during charge cycle SKODA_DPF_STATISTICS_AVG_DRIVE

  • Service 22DID 4033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter statistics, calculated charging rate in charge cycle, g/km SKODA_DPF_STATISTICS_CALC_G

  • Service 22DID 401D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×12207100000000
Range
-3.99 to 3.99
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics, current average speed in charge cycle SKODA_DPF_STATISTICS

  • Service 22DID 400A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 km/h
Unit
km/h

In testing for 2001 to 2026.

Diesel particulate filter statistics, measured charging rate in charge cycle, g/km SKODA_DPF_STATISTICS_MEAS_G

  • Service 22DID 401B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×12207100000000
Range
-3.99 to 3.99
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics, route in charge cycle SKODA_DPF_STATISTICS_ROUTE

  • Service 22DID 4031
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8
Range
0 to 2040 km
Unit
km

In testing for 2001 to 2026.

Diesel particulate filter, differential pressure sensor, voltage SKODA_DPF_DIFF_P_SENS_V

  • Service 22DID 4493
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Discharge voltage, min SKODA_MINIMUM_DISCHARGE_V

  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2001 to 2026.

Ecall battery charge status SKODA_ECALL_BATTERY_CHARGE_STATUS

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

ECall battery status SKODA_ECALL_STATUS

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
1CRITICAL
2NORMAL

In testing for 2001 to 2026.

Electric machine high-voltage battery energy information SKODA_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2001 to 2026.

Electric motor battery energy SKODA_EM_HVBAT_E_INFO

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2001 to 2026.

Emergency call battery critical status SKODA_ECALL_BAT_CRIT

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Emergency call battery level SKODA_ECALL_BAT_LVL

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Energy turnover total SKODA_CHRGR_E_TOTAL

  • Service 22DID 15EF
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

In testing for 2001 to 2026.

Engine read 105E, signed raw count SKODA_105E_RAW

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2001 to 2026.

Estimated reserve range SKODA_E_TRON_RANGE_EST_CAN

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Estimated reserve range SKODA_RANGE_EST_CAN

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Exhaust gas recirculation valve 1, B1, mass current: specified value SKODA_MQB_EGR_VALVE_1_B1_MASS_I_SPEC

  • Service 22DID 1813
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Exhaust gas recirculation valve 2, B1, mass current: specified value SKODA_MQB_EGR_VALVE_2_B1_MASS_I_SPEC

  • Service 22DID 1814
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Generator target voltage SKODA_MQB_GEN_TRG_V

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
10.6 to 36.1 V
Unit
V

In testing for 2001 to 2026.

Generator voltage, actual SKODA_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2001 to 2026.

High pressure exhaust gas recirculation actuator, actual unconditioned voltage SKODA_HIGH_P_EGR_ACTUATOR_ACT_V

  • Service 22DID 11A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2001 to 2026.

High pressure turbocharger actuator, activation SKODA_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

High pressure turbocharger actuator, actual unconditioned voltage SKODA_HIGH_P_TURBOCHARGER_ACT_V

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2001 to 2026.

High voltage battery energy information SKODA_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2001 to 2026.

High voltage battery inlet temperature SKODA_HVBAT_INLET_T

  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2001 to 2026.

High voltage battery mode SKODA_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7

  • Service 22DID 7448
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

High voltage battery outlet temperature SKODA_HVBAT_OUTLET_T

  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2001 to 2026.

High voltage battery total charge ah SKODA_HVBAT_TOT_CHG_AH

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818749 Ah
Unit
Ah

In testing for 2001 to 2026.

High voltage battery total charge kwh SKODA_HVBAT_TOT_CHG_KWH

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500399 kWh
Unit
kWh

In testing for 2001 to 2026.

High voltage battery total discharge ah SKODA_HVBAT_TOT_DCHG_AH

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818749 Ah
Unit
Ah

In testing for 2001 to 2026.

High voltage battery total discharge kwh SKODA_HVBAT_TOT_DCHG_KWH

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500399 kWh
Unit
kWh

In testing for 2001 to 2026.

High voltage output SKODA_OBC_HIGH_V_OUTPUT

  • Service 22DID 1DA7
  • Module744
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

High-voltage battery charge SKODA_E_TRON_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

High-voltage battery charge SKODA_HVBAT_SOC_V2

  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV auxiliary current total SKODA_HVAUX_I

  • Service 22DID 0360
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2001 to 2026.

HV auxiliary power SKODA_HVAUX_PWR

  • Service 22DID 0364
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kW
Unit
kW

In testing for 2001 to 2026.

HV battery after contacts voltage SKODA_HVBAT_AFTER_CONTACTS_V

  • Service 22DID 189B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 V
Unit
V

In testing for 2001 to 2026.

HV battery capacity SKODA_HVBAT_CAP

Total possible energy in the high voltage battery

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery capacity SKODA_HVBAT_CAP_24KWH

Total possible energy in the high voltage battery

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery cell 1 voltage SKODA_HVBAT_CELL_1_V

  • Service 22DID 1E40
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 2 voltage SKODA_HVBAT_CELL_2_V

  • Service 22DID 1E41
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 3 voltage SKODA_HVBAT_CELL_3_V

  • Service 22DID 1E42
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 4 voltage SKODA_HVBAT_CELL_4_V

  • Service 22DID 1E43
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 5 voltage SKODA_HVBAT_CELL_5_V

  • Service 22DID 1E44
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 6 voltage SKODA_HVBAT_CELL_6_V

  • Service 22DID 1E45
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 7 voltage SKODA_HVBAT_CELL_7_V

  • Service 22DID 1E46
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 8 voltage SKODA_HVBAT_CELL_8_V

  • Service 22DID 1E47
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 9 voltage SKODA_HVBAT_CELL_9_V

  • Service 22DID 1E48
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 10 voltage SKODA_HVBAT_CELL_10_V

  • Service 22DID 1E49
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 11 voltage SKODA_HVBAT_CELL_11_V

  • Service 22DID 1E4A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 12 voltage SKODA_HVBAT_CELL_12_V

  • Service 22DID 1E4B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 13 voltage SKODA_HVBAT_CELL_13_V

  • Service 22DID 1E4C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 14 voltage SKODA_HVBAT_CELL_14_V

  • Service 22DID 1E4D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 15 voltage SKODA_HVBAT_CELL_15_V

  • Service 22DID 1E4E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 16 voltage SKODA_HVBAT_CELL_16_V

  • Service 22DID 1E4F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 17 voltage SKODA_HVBAT_CELL_17_V

  • Service 22DID 1E50
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 18 voltage SKODA_HVBAT_CELL_18_V

  • Service 22DID 1E51
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 19 voltage SKODA_HVBAT_CELL_19_V

  • Service 22DID 1E52
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 20 voltage SKODA_HVBAT_CELL_20_V

  • Service 22DID 1E53
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 21 voltage SKODA_HVBAT_CELL_21_V

  • Service 22DID 1E54
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 22 voltage SKODA_HVBAT_CELL_22_V

  • Service 22DID 1E55
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 23 voltage SKODA_HVBAT_CELL_23_V

  • Service 22DID 1E56
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 24 voltage SKODA_HVBAT_CELL_24_V

  • Service 22DID 1E57
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 25 voltage SKODA_HVBAT_CELL_25_V

  • Service 22DID 1E58
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 26 voltage SKODA_HVBAT_CELL_26_V

  • Service 22DID 1E59
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 27 voltage SKODA_HVBAT_CELL_27_V

  • Service 22DID 1E5A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 28 voltage SKODA_HVBAT_CELL_28_V

  • Service 22DID 1E5B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 29 voltage SKODA_HVBAT_CELL_29_V

  • Service 22DID 1E5C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 30 voltage SKODA_HVBAT_CELL_30_V

  • Service 22DID 1E5D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 31 voltage SKODA_HVBAT_CELL_31_V

  • Service 22DID 1E5E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 32 voltage SKODA_HVBAT_CELL_32_V

  • Service 22DID 1E5F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 33 voltage SKODA_HVBAT_CELL_33_V

  • Service 22DID 1E60
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 34 voltage SKODA_HVBAT_CELL_34_V

  • Service 22DID 1E61
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 35 voltage SKODA_HVBAT_CELL_35_V

  • Service 22DID 1E62
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 36 voltage SKODA_HVBAT_CELL_36_V

  • Service 22DID 1E63
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 37 voltage SKODA_HVBAT_CELL_37_V

  • Service 22DID 1E64
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 38 voltage SKODA_HVBAT_CELL_38_V

  • Service 22DID 1E65
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 39 voltage SKODA_HVBAT_CELL_39_V

  • Service 22DID 1E66
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 40 voltage SKODA_HVBAT_CELL_40_V

  • Service 22DID 1E67
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 41 voltage SKODA_HVBAT_CELL_41_V

  • Service 22DID 1E68
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 42 voltage SKODA_HVBAT_CELL_42_V

  • Service 22DID 1E69
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 43 voltage SKODA_HVBAT_CELL_43_V

  • Service 22DID 1E6A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 44 voltage SKODA_HVBAT_CELL_44_V

  • Service 22DID 1E6B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 45 voltage SKODA_HVBAT_CELL_45_V

  • Service 22DID 1E6C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 46 voltage SKODA_HVBAT_CELL_46_V

  • Service 22DID 1E6D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 47 voltage SKODA_HVBAT_CELL_47_V

  • Service 22DID 1E6E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 48 voltage SKODA_HVBAT_CELL_48_V

  • Service 22DID 1E6F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 49 voltage SKODA_HVBAT_CELL_49_V

  • Service 22DID 1E70
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 50 voltage SKODA_HVBAT_CELL_50_V

  • Service 22DID 1E71
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 51 voltage SKODA_HVBAT_CELL_51_V

  • Service 22DID 1E72
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 52 voltage SKODA_HVBAT_CELL_52_V

  • Service 22DID 1E73
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 53 voltage SKODA_HVBAT_CELL_53_V

  • Service 22DID 1E74
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 54 voltage SKODA_HVBAT_CELL_54_V

  • Service 22DID 1E75
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 55 voltage SKODA_HVBAT_CELL_55_V

  • Service 22DID 1E76
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 56 voltage SKODA_HVBAT_CELL_56_V

  • Service 22DID 1E77
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 57 voltage SKODA_HVBAT_CELL_57_V

  • Service 22DID 1E78
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 58 voltage SKODA_HVBAT_CELL_58_V

  • Service 22DID 1E79
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 59 voltage SKODA_HVBAT_CELL_59_V

  • Service 22DID 1E7A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 60 voltage SKODA_HVBAT_CELL_60_V

  • Service 22DID 1E7B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 61 voltage SKODA_HVBAT_CELL_61_V

  • Service 22DID 1E7C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 62 voltage SKODA_HVBAT_CELL_62_V

  • Service 22DID 1E7D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 63 voltage SKODA_HVBAT_CELL_63_V

  • Service 22DID 1E7E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 64 voltage SKODA_HVBAT_CELL_64_V

  • Service 22DID 1E7F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 65 voltage SKODA_HVBAT_CELL_65_V

  • Service 22DID 1E80
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 66 voltage SKODA_HVBAT_CELL_66_V

  • Service 22DID 1E81
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 67 voltage SKODA_HVBAT_CELL_67_V

  • Service 22DID 1E82
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 68 voltage SKODA_HVBAT_CELL_68_V

  • Service 22DID 1E83
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 69 voltage SKODA_HVBAT_CELL_69_V

  • Service 22DID 1E84
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 70 voltage SKODA_HVBAT_CELL_70_V

  • Service 22DID 1E85
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 71 voltage SKODA_HVBAT_CELL_71_V

  • Service 22DID 1E86
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 72 voltage SKODA_HVBAT_CELL_72_V

  • Service 22DID 1E87
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 73 voltage SKODA_HVBAT_CELL_73_V

  • Service 22DID 1E88
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 74 voltage SKODA_HVBAT_CELL_74_V

  • Service 22DID 1E89
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 75 voltage SKODA_HVBAT_CELL_75_V

  • Service 22DID 1E8A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 76 voltage SKODA_HVBAT_CELL_76_V

  • Service 22DID 1E8B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 77 voltage SKODA_HVBAT_CELL_77_V

  • Service 22DID 1E8C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 78 voltage SKODA_HVBAT_CELL_78_V

  • Service 22DID 1E8D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 79 voltage SKODA_HVBAT_CELL_79_V

  • Service 22DID 1E8E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 80 voltage SKODA_HVBAT_CELL_80_V

  • Service 22DID 1E8F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 81 voltage SKODA_HVBAT_CELL_81_V

  • Service 22DID 1E90
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 82 voltage SKODA_HVBAT_CELL_82_V

  • Service 22DID 1E91
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 83 voltage SKODA_HVBAT_CELL_83_V

  • Service 22DID 1E92
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 84 voltage SKODA_HVBAT_CELL_84_V

  • Service 22DID 1E93
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 85 voltage SKODA_HVBAT_CELL_85_V

  • Service 22DID 1E94
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 86 voltage SKODA_HVBAT_CELL_86_V

  • Service 22DID 1E95
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 87 voltage SKODA_HVBAT_CELL_87_V

  • Service 22DID 1E96
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 88 voltage SKODA_HVBAT_CELL_88_V

  • Service 22DID 1E97
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 89 voltage SKODA_HVBAT_CELL_89_V

  • Service 22DID 1E98
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 90 voltage SKODA_HVBAT_CELL_90_V

  • Service 22DID 1E99
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 91 voltage SKODA_HVBAT_CELL_91_V

  • Service 22DID 1E9A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 92 voltage SKODA_HVBAT_CELL_92_V

  • Service 22DID 1E9B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 93 voltage SKODA_HVBAT_CELL_93_V

  • Service 22DID 1E9C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 94 voltage SKODA_HVBAT_CELL_94_V

  • Service 22DID 1E9D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 95 voltage SKODA_HVBAT_CELL_95_V

  • Service 22DID 1E9E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 96 voltage SKODA_HVBAT_CELL_96_V

  • Service 22DID 1E9F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 97 voltage SKODA_HVBAT_CELL_97_V

  • Service 22DID 1EA0
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 98 voltage SKODA_HVBAT_CELL_98_V

  • Service 22DID 1EA1
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 99 voltage SKODA_HVBAT_CELL_99_V

  • Service 22DID 1EA2
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 100 voltage SKODA_HVBAT_CELL_100_V

  • Service 22DID 1EA3
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 101 voltage SKODA_HVBAT_CELL_101_V

  • Service 22DID 1EA4
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell 102 voltage SKODA_HVBAT_CELL_102_V

  • Service 22DID 1EA5
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage max, ID SKODA_HVBAT_CELL_V_MAX_ID

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

HV battery cell voltage max, ID SKODA_HVBAT_CELL_V_MAX_ID_2026

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery cell voltage min, ID SKODA_HVBAT_CELL_V_MIN_ID

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

HV battery cell voltage min, ID SKODA_HVBAT_CELL_V_MIN_ID_2026

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery cell voltage sum SKODA_HVBAT_CELL_SUM_V

  • Service 22DID 1E3C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val4096
Range
0 to 4095.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, maximum SKODA_HVBAT_CELL_V_MAX

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, maximum SKODA_HVBAT_CELL_V_MAX_2026

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, maximum SKODA_HVBAT_CELL_V_MAX_V2

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, minimum SKODA_HVBAT_CELL_V_MIN

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, minimum SKODA_HVBAT_CELL_V_MIN_2026

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, minimum SKODA_HVBAT_CELL_V_MIN_V2

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2001 to 2026.

HV battery charge SKODA_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery charge (displayed) SKODA_HVBAT_SOC_DISP_V2

HV battery charge displayed on the dashboard

Pelican can show this parameter as the state of charge.

  • Service 22DID 08D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery charge current limit SKODA_HVBAT_CHG_I_LIM

  • Service 22DID 1E1B
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

HV battery charge current limit, predicted SKODA_HVBAT_CHG_I_LIM_PRED

  • Service 22DID 1E1D
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

HV battery charge throughput SKODA_HVBAT_AH_CHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2001 to 2026.

HV battery charge, displayed SKODA_HVBAT_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery charge, normalized SKODA_PE_SOC

  • Service 22DID F404
  • Module7E6
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery coldest sensor SKODA_HVBAT_T_MIN_NO

  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery coolant pump control value SKODA_BMS_COOL_PUMP_CTL

  • Service 22DID 80EC
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

HV battery current SKODA_BMS_I

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1802
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2.56−1500
Range
-1500 to 166269 A
Unit
A

In testing for 2001 to 2026.

HV battery current SKODA_HVBAT_CURRENT

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−511
Range
-200 to 200 A
Unit
A

In testing for 2001 to 2026.

HV battery current SKODA_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−511
Range
-200 to 200 A
Unit
A

In testing for 2001 to 2026.

HV battery discharge current limit SKODA_HVBAT_DISCHG_I_LIM

  • Service 22DID 1E1C
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

HV battery discharge current limit, predicted SKODA_HVBAT_DISCHG_I_LIM_PRED

  • Service 22DID 1E1E
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

HV battery discharge throughput SKODA_HVBAT_AH_DISCHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val549.31642
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2001 to 2026.

HV battery energy SKODA_HVBAT_KWH

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery energy SKODA_HVBAT_KWH_V2

Energy stored in the high voltage battery

Pelican can show this parameter as the traction battery capacity.

  • Service 22DID 4965
  • Module744 → 7AE
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery energy charged SKODA_HVBAT_KWH_CHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500300 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery energy content SKODA_E_TRON_HVBAT_E_CONTENT

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery energy content SKODA_HVBAT_E_CONTENT

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638.37 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery energy discharged SKODA_HVBAT_KWH_DISCHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199.883 to 250199.883 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery health SKODA_E_TRON_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 6524 %
Unit
%

In testing for 2001 to 2026.

HV battery health SKODA_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery highest cell SKODA_HVBAT_CELL_V_MAX_NO

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery hottest sensor SKODA_HVBAT_T_MAX_NO

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery isolation resistance, negative SKODA_HVBAT_ISO_NEG

  • Service 22DID 1E1A
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2001 to 2026.

HV battery isolation resistance, positive SKODA_HVBAT_ISO_POS

  • Service 22DID 1E18
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2001 to 2026.

HV battery lowest cell SKODA_HVBAT_CELL_V_MIN_NO

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery maximum energy, raw count SKODA_HVBAT_E_MAX_RAW

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

HV battery maximum power SKODA_HVBAT_PWR_MAX

  • Service 22DID 1502
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2001 to 2026.

HV battery module temperature, #1 SKODA_HVBAT_MOD_T_1

  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #2 SKODA_HVBAT_MOD_T_2

  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #3 SKODA_HVBAT_MOD_T_3

  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #4 SKODA_HVBAT_MOD_T_4

  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #17 SKODA_HVBAT_MOD_T_17

  • Service 22DID 7425
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #18 SKODA_HVBAT_MOD_T_18

  • Service 22DID 7426
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #19 SKODA_HVBAT_MOD_T_19

  • Service 22DID 7427
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #20 SKODA_HVBAT_MOD_T_20

  • Service 22DID 7428
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #21 SKODA_HVBAT_MOD_T_21

  • Service 22DID 7429
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #22 SKODA_HVBAT_MOD_T_22

  • Service 22DID 742A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #23 SKODA_HVBAT_MOD_T_23

  • Service 22DID 742B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #24 SKODA_HVBAT_MOD_T_24

  • Service 22DID 742C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery negative voltage before the contactors SKODA_HVBAT_NEG_V_PRE

  • Service 22DID 1E35
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 V
Unit
V

In testing for 2001 to 2026.

HV battery positive voltage after the charging contactors SKODA_HVBAT_POS_V_POST_CHG

  • Service 22DID 1E39
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 V
Unit
V

In testing for 2001 to 2026.

HV battery positive voltage before the contactors SKODA_HVBAT_POS_V_PRE

  • Service 22DID 1E36
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

HV battery power SKODA_HVBAT_PWR

  • Service 22DID 1485
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2001 to 2026.

HV battery relative temperature SKODA_HVBAT_T_REL

  • Service 22DID 149B
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

HV battery remaining charge SKODA_HVBAT_REMAINING

  • Service 22DID F45B
  • Module7E0
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery state of charge SKODA_BMS_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery state of charge display SKODA_CHRGR_SOC_DISP

  • Service 22DID 1DD0
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery state of charge display SKODA_E_TRON_CHRGR_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Service 22DID 1DD0
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery state of charge, hd SKODA_BMS_SOC_HIRES

  • Service 22DID F45B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery state of charge, hd SKODA_E_TRON_BMS_SOC_HIRES

Pelican can show this parameter as the state of charge.

  • Service 22DID F45B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery temperature SKODA_HVBAT_T

  • Service 22DID 2A0B
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature load SKODA_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

HV battery temperature sensor 1 SKODA_HVBAT_T_1

  • Service 22DID 1EAE
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 2 SKODA_HVBAT_T_2

  • Service 22DID 1EAF
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 3 SKODA_HVBAT_T_3

  • Service 22DID 1EB0
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 4 SKODA_HVBAT_T_4

  • Service 22DID 1EB1
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 5 SKODA_HVBAT_T_5

  • Service 22DID 1EB2
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 6 SKODA_HVBAT_T_6

  • Service 22DID 1EB3
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 7 SKODA_HVBAT_T_7

  • Service 22DID 1EB4
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 8 SKODA_HVBAT_T_8

  • Service 22DID 1EB5
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 9 SKODA_HVBAT_T_9

  • Service 22DID 1EB6
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 10 SKODA_HVBAT_T_10

  • Service 22DID 1EB7
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 11 SKODA_HVBAT_T_11

  • Service 22DID 1EB8
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 12 SKODA_HVBAT_T_12

  • Service 22DID 1EB9
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 13 SKODA_HVBAT_T_13

  • Service 22DID 1EBA
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 15 SKODA_HVBAT_T_15

  • Service 22DID 1EBC
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 16 SKODA_HVBAT_T_16

  • Service 22DID 1EBD
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature sensor 17 SKODA_HVBAT_T_17

  • Service 22DID 7425
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, average SKODA_BMS_T_AVG

  • Service 22DID 1E10
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, maximum SKODA_BMS_T_MAX

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, maximum SKODA_HVBAT_T_MAX

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, maximum (cell #) SKODA_BMS_T_MAX_CELL

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery temperature, minimum SKODA_BMS_T_MIN

  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, minimum SKODA_BMS_T_MIN_V2

  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

HV battery temperature, minimum (cell #) SKODA_BMS_T_MIN_CELL

  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery total kilowatt hours of discharge SKODA_HVBAT_TOT_KWH_DCHRG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199 to 250199 kWh
Unit
kWh

In testing for 2001 to 2026.

HV battery voltage SKODA_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage SKODA_HVBAT_VOLT

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1801
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage SKODA_HVBAT_VOLTS

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage, measurement 2 SKODA_HVBAT_V_180A

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 180A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage, measurement 3 SKODA_HVBAT_V_180B

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 180B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage, measurement 4 SKODA_HVBAT_V_1818

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 1818
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

HV battery voltage, measurement 5 SKODA_HVBAT_V_181B

Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.

  • Service 22DID 181B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

HV battery, max energy SKODA_HVBAT_E_MAX

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

In testing for 2001 to 2026.

HV battery: circulation pump flow SKODA_CIRC_PUMP_FLOW

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV booster, commanded current SKODA_CHRGR_BOOST_CMD_I

  • Service 22DID 155A
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

In testing for 2001 to 2026.

HV booster, commanded voltage SKODA_CHRGR_BOOST_CMD_V

  • Service 22DID 1559
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

In testing for 2001 to 2026.

HV booster, HV highside current SKODA_CHRGR_BOOST_HI_I

  • Service 22DID 1553
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

In testing for 2001 to 2026.

HV booster, HV highside voltage SKODA_CHRGR_BOOST_HI_V

  • Service 22DID 1554
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

In testing for 2001 to 2026.

HV booster, HV lowside current SKODA_CHRGR_BOOST_LO_I

  • Service 22DID 1557
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 A
Unit
A

In testing for 2001 to 2026.

HV booster, HV lowside voltage SKODA_CHRGR_BOOST_LO_V

  • Service 22DID 1558
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

In testing for 2001 to 2026.

HV interlock detector voltage SKODA_HV_INTERLOCK_DET_V

  • Service 22DID 74B9
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2001 to 2026.

HV interlock source current SKODA_HV_INTERLOCK_SRC_I

  • Service 22DID 74BC
  • Module7E5
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 mA
Unit
mA

In testing for 2001 to 2026.

HV interlock source voltage SKODA_HV_INTERLOCK_SRC_V

  • Service 22DID 74BA
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2001 to 2026.

HV system isolation resistance, negative SKODA_HV_ISO_NEG_SYS

  • Service 22DID 1E19
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2001 to 2026.

HV system isolation resistance, positive SKODA_HV_ISO_POS_SYS

  • Service 22DID 1E17
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2001 to 2026.

Ignition angle current cylinder SKODA_IGN_ANG_CYL

  • Service 22DID 137A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−35.625
Range
-35.625 to 60 N·m
Unit
N·m

In testing for 2001 to 2026.

Knock sensor voltage, cylinder 1 SKODA_KNOCK_SENS_V_CYL_1_7E0

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage, cylinder 3 SKODA_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 1 SKODA_KNOCK_SENS_V_CYL_1

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 2 SKODA_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 3 SKODA_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 4 SKODA_KNOCK_SENS_V_CYL_4

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 5 SKODA_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensor voltage:, cylinder 6 SKODA_KNOCK_SENS_V_CYL_6

  • Service 22DID 13FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2001 to 2026.

Knock sensors average voltage bank 1, variant 2 SKODA_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Maximum charge current SKODA_MAX_CHA_CUR_2

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2001 to 2026.

Maximum charge power SKODA_CHRGR_CHG_PWR_MAX

  • Service 22DID 1DD3
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Maximum charge voltage SKODA_BMS_V_CHG_MAX

  • Service 22DID 5171
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Maximum charging power SKODA_CHRGR_PWR_MAX

  • Service 22DID 15D5
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2001 to 2026.

Maximum discharge current SKODA_MAX_DCHA_CUR_2

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2001 to 2026.

Maximum dynamic charge current limit SKODA_BMS_I_CHG_LIM_DYN

  • Service 22DID 1E1B
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2001 to 2026.

Maximum dynamic discharge current limit SKODA_BMS_I_DCHG_LIM_DYN

  • Service 22DID 1E1C
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2001 to 2026.

Maximum predicted charge current limit SKODA_BMS_I_CHG_LIM_PRED

  • Service 22DID 1E1D
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2001 to 2026.

Maximum predicted discharge current limit SKODA_BMS_I_DCHG_LIM_PRED

  • Service 22DID 1E1E
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2001 to 2026.

Minimum discharge voltage SKODA_BMS_V_DCHG_MIN

  • Service 22DID 5170
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Minimum dynamic charge voltage SKODA_BMS_V_CHG_DYN_MIN

  • Service 22DID 5174
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Minimum dynamic discharge voltage SKODA_BMS_V_DCHG_DYN_MIN

  • Service 22DID 5175
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Minimum predicted charge voltage SKODA_BMS_V_CHG_PRED_MIN

  • Service 22DID 5172
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Minimum predicted discharge voltage SKODA_BMS_V_DCHG_PRED_MIN

  • Service 22DID 5173
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2001 to 2026.

Non-vehicle energy requirement SKODA_NV_ENERGY_REQUIREMENT

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2001 to 2026.

Nox sulfur charge SKODA_NOX_SULFUR_CHG

  • Service 22DID 4366
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

On-board charger, hv/dc current SKODA_OBC_HVDC_C

  • Service 22DID 103D
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2001 to 2026.

Onboard electrical system current SKODA_AUX_I

  • Service 22DID 1617
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2001 to 2026.

Onboard electrical system power SKODA_AUX_PWR

  • Service 22DID 1077
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2001 to 2026.

Particle sensor, heat voltage SKODA_PARTICLE_SENS_HEAT_V

  • Service 22DID 44FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 V
Unit
V

In testing for 2001 to 2026.

Power efficiency SKODA_CHRGR_EFFICIENCY

  • Service 22DID 15D6
  • Module744
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
75 to 100.5 A
Unit
A

In testing for 2001 to 2026.

Power electronics terminal 30 voltage SKODA_PE_KL30_V

  • Service 22DID 465D
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2001 to 2026.

Power loss battery charger SKODA_CHRGR_PWR_LOSS

  • Service 22DID 15E1
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100
Unit
Raw value

In testing for 2001 to 2026.

PRX voltage charging connector b SKODA_CHRGR_PRX_V_CONN_B

  • Service 22DID 1529
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2001 to 2026.

Rail 1 energy transformation SKODA_CHRGR_RAIL1_E

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

In testing for 2001 to 2026.

Rail 2 energy transformation SKODA_CHRGR_RAIL2_E

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

In testing for 2001 to 2026.

Rail 3 energy transformation SKODA_CHRGR_RAIL3_E

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

In testing for 2001 to 2026.

Service regeneration current duration SKODA_PQ35_SRV_REGEN_DUR

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.0001666667
Range
0 to 715827 min
Unit
min

In testing for 2001 to 2026.

Start/stop battery charge SKODA_SSB_AH

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2001 to 2026.

Start/stop battery current SKODA_SSB_C

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2001 to 2026.

Start/stop battery current SKODA_SSB_C_32

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000 to 1000 A
Unit
A

In testing for 2001 to 2026.

Start/stop battery resistance SKODA_SSB_R

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×210
Range
0 to 51 mΩ
Unit
mΩ

In testing for 2001 to 2026.

Start/stop battery sensor temperature SKODA_SSB_SENSOR_T

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Start/stop battery sensor temperature SKODA_SSB_T

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Start/stop battery state of charge SKODA_SSB_SOC

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Start/stop battery target voltage SKODA_SSB_VT

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2001 to 2026.

Start/stop battery total charge SKODA_SSB_TOTAL_CHARGE

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 100 Ah
Unit
Ah

In testing for 2001 to 2026.

Start/stop battery total discharge SKODA_SSB_TOTAL_DISCHARGE

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 100 Ah
Unit
Ah

In testing for 2001 to 2026.

Start/stop battery voltage SKODA_SSB_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.53 V
Unit
V

In testing for 2001 to 2026.

Start/stop battery voltage, at rest SKODA_SSB_V_REST

  • Service 22DID 2A10
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

In testing for 2001 to 2026.

State of charge SKODA_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

State of charge SKODA_SOC_FC00

Pelican can show this parameter as the state of charge.

  • Service 22DID 3DEF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

State of charge SKODA_SOC_V2

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

State of charge SKODA_SOC_V3

  • Service 22DID 3DEF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

State of charge, display SKODA_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20.446−6.4
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Temperature sensor for engine temperature management voltage SKODA_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Temperature sensor, socket a SKODA_OBC_T_A

  • Service 22DID 1DDA
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498.5 °C
Unit
°C

In testing for 2001 to 2026.

Temperature, battery SKODA_BATTERY_T

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2001 to 2026.

Terminal 30 voltage SKODA_KL30_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2001 to 2026.

Traction current reported by the battery management system SKODA_PE_BMS_HV_I

  • Service 22DID 465F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Traction voltage reported by the battery management system SKODA_PE_BMS_HV_V

  • Service 22DID 466E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

Turbocharger inlet pressure corrected value SKODA_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Voltage proximity, socket a SKODA_OBC_V_PROX_A

  • Service 22DID 1525
  • Module744 → 7AE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2001 to 2026.

Cells

HV battery cell voltage, #1 SKODA_HVBAT_CELL_V_001

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #2 SKODA_HVBAT_CELL_V_002

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #3 SKODA_HVBAT_CELL_V_003

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #4 SKODA_HVBAT_CELL_V_004

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #5 SKODA_HVBAT_CELL_V_005

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #6 SKODA_HVBAT_CELL_V_006

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #7 SKODA_HVBAT_CELL_V_007

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #8 SKODA_HVBAT_CELL_V_008

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #9 SKODA_HVBAT_CELL_V_009

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #10 SKODA_HVBAT_CELL_V_010

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #11 SKODA_HVBAT_CELL_V_011

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #12 SKODA_HVBAT_CELL_V_012

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #13 SKODA_HVBAT_CELL_V_013

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #14 SKODA_HVBAT_CELL_V_014

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #15 SKODA_HVBAT_CELL_V_015

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #16 SKODA_HVBAT_CELL_V_016

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #17 SKODA_HVBAT_CELL_V_017

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #18 SKODA_HVBAT_CELL_V_018

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #19 SKODA_HVBAT_CELL_V_019

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #20 SKODA_HVBAT_CELL_V_020

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #21 SKODA_HVBAT_CELL_V_021

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #22 SKODA_HVBAT_CELL_V_022

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #23 SKODA_HVBAT_CELL_V_023

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #24 SKODA_HVBAT_CELL_V_024

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #25 SKODA_HVBAT_CELL_V_025

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #26 SKODA_HVBAT_CELL_V_026

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #27 SKODA_HVBAT_CELL_V_027

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #28 SKODA_HVBAT_CELL_V_028

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #29 SKODA_HVBAT_CELL_V_029

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #30 SKODA_HVBAT_CELL_V_030

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #31 SKODA_HVBAT_CELL_V_031

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #32 SKODA_HVBAT_CELL_V_032

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #33 SKODA_HVBAT_CELL_V_033

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #34 SKODA_HVBAT_CELL_V_034

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #35 SKODA_HVBAT_CELL_V_035

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #36 SKODA_HVBAT_CELL_V_036

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #37 SKODA_HVBAT_CELL_V_037

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #38 SKODA_HVBAT_CELL_V_038

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #39 SKODA_HVBAT_CELL_V_039

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #40 SKODA_HVBAT_CELL_V_040

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #41 SKODA_HVBAT_CELL_V_041

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #42 SKODA_HVBAT_CELL_V_042

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #43 SKODA_HVBAT_CELL_V_043

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #44 SKODA_HVBAT_CELL_V_044

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #45 SKODA_HVBAT_CELL_V_045

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #46 SKODA_HVBAT_CELL_V_046

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #47 SKODA_HVBAT_CELL_V_047

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #48 SKODA_HVBAT_CELL_V_048

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #49 SKODA_HVBAT_CELL_V_049

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #50 SKODA_HVBAT_CELL_V_050

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #51 SKODA_HVBAT_CELL_V_051

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #52 SKODA_HVBAT_CELL_V_052

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #53 SKODA_HVBAT_CELL_V_053

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #54 SKODA_HVBAT_CELL_V_054

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #55 SKODA_HVBAT_CELL_V_055

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #56 SKODA_HVBAT_CELL_V_056

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #57 SKODA_HVBAT_CELL_V_057

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #58 SKODA_HVBAT_CELL_V_058

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #59 SKODA_HVBAT_CELL_V_059

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #60 SKODA_HVBAT_CELL_V_060

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #61 SKODA_HVBAT_CELL_V_061

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #62 SKODA_HVBAT_CELL_V_062

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #63 SKODA_HVBAT_CELL_V_063

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #64 SKODA_HVBAT_CELL_V_064

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #65 SKODA_HVBAT_CELL_V_065

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #66 SKODA_HVBAT_CELL_V_066

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #67 SKODA_HVBAT_CELL_V_067

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #68 SKODA_HVBAT_CELL_V_068

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #69 SKODA_HVBAT_CELL_V_069

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #70 SKODA_HVBAT_CELL_V_070

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #71 SKODA_HVBAT_CELL_V_071

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #72 SKODA_HVBAT_CELL_V_072

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #73 SKODA_HVBAT_CELL_V_073

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #74 SKODA_HVBAT_CELL_V_074

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #75 SKODA_HVBAT_CELL_V_075

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #76 SKODA_HVBAT_CELL_V_076

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #77 SKODA_HVBAT_CELL_V_077

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #78 SKODA_HVBAT_CELL_V_078

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #79 SKODA_HVBAT_CELL_V_079

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #80 SKODA_HVBAT_CELL_V_080

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #81 SKODA_HVBAT_CELL_V_081

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #82 SKODA_HVBAT_CELL_V_082

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #83 SKODA_HVBAT_CELL_V_083

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #84 SKODA_HVBAT_CELL_V_084

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #85 SKODA_HVBAT_CELL_V_085

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #86 SKODA_HVBAT_CELL_V_086

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #87 SKODA_HVBAT_CELL_V_087

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #88 SKODA_HVBAT_CELL_V_088

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #89 SKODA_HVBAT_CELL_V_089

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #90 SKODA_HVBAT_CELL_V_090

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #91 SKODA_HVBAT_CELL_V_091

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #92 SKODA_HVBAT_CELL_V_092

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #93 SKODA_HVBAT_CELL_V_093

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #94 SKODA_HVBAT_CELL_V_094

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #95 SKODA_HVBAT_CELL_V_095

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #96 SKODA_HVBAT_CELL_V_096

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #97 SKODA_HVBAT_CELL_V_097

  • Service 22DID 1EA0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #98 SKODA_HVBAT_CELL_V_098

  • Service 22DID 1EA1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #99 SKODA_HVBAT_CELL_V_099

  • Service 22DID 1EA2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #100 SKODA_HVBAT_CELL_V_100

  • Service 22DID 1EA3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #101 SKODA_HVBAT_CELL_V_101

  • Service 22DID 1EA4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #102 SKODA_HVBAT_CELL_V_102

  • Service 22DID 1EA5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #103 SKODA_HVBAT_CELL_V_103

  • Service 22DID 1EA6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #104 SKODA_HVBAT_CELL_V_104

  • Service 22DID 1EA7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #105 SKODA_HVBAT_CELL_V_105

  • Service 22DID 1EA8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #106 SKODA_HVBAT_CELL_V_106

  • Service 22DID 1EA9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #107 SKODA_HVBAT_CELL_V_107

  • Service 22DID 1EAA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery cell voltage, #108 SKODA_HVBAT_CELL_V_108

  • Service 22DID 1EAB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 1 state of charge SKODA_HVBAT_MOD1_C1_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 1 voltage SKODA_HVBAT_MOD1_C1_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 2 state of charge SKODA_HVBAT_MOD1_C2_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 2 voltage SKODA_HVBAT_MOD1_C2_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 3 state of charge SKODA_HVBAT_MOD1_C3_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 3 voltage SKODA_HVBAT_MOD1_C3_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 4 state of charge SKODA_HVBAT_MOD1_C4_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 4 voltage SKODA_HVBAT_MOD1_C4_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 5 state of charge SKODA_HVBAT_MOD1_C5_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 5 voltage SKODA_HVBAT_MOD1_C5_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 cell 6 state of charge SKODA_HVBAT_MOD1_C6_SOC

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 1 cell 6 voltage SKODA_HVBAT_MOD1_C6_V

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 1 id SKODA_HVBAT_MOD1_ID

  • Service 22DID 1850
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 2 cell 1 state of charge SKODA_HVBAT_MOD2_C1_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 1 voltage SKODA_HVBAT_MOD2_C1_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 cell 2 state of charge SKODA_HVBAT_MOD2_C2_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 2 voltage SKODA_HVBAT_MOD2_C2_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 cell 3 state of charge SKODA_HVBAT_MOD2_C3_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 3 voltage SKODA_HVBAT_MOD2_C3_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 cell 4 state of charge SKODA_HVBAT_MOD2_C4_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 4 voltage SKODA_HVBAT_MOD2_C4_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 cell 5 state of charge SKODA_HVBAT_MOD2_C5_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 5 voltage SKODA_HVBAT_MOD2_C5_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 cell 6 state of charge SKODA_HVBAT_MOD2_C6_SOC

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 2 cell 6 voltage SKODA_HVBAT_MOD2_C6_V

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 2 id SKODA_HVBAT_MOD2_ID

  • Service 22DID 1851
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 3 cell 1 state of charge SKODA_HVBAT_MOD3_C1_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 1 voltage SKODA_HVBAT_MOD3_C1_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 cell 2 state of charge SKODA_HVBAT_MOD3_C2_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 2 voltage SKODA_HVBAT_MOD3_C2_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 cell 3 state of charge SKODA_HVBAT_MOD3_C3_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 3 voltage SKODA_HVBAT_MOD3_C3_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 cell 4 state of charge SKODA_HVBAT_MOD3_C4_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 4 voltage SKODA_HVBAT_MOD3_C4_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 cell 5 state of charge SKODA_HVBAT_MOD3_C5_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 5 voltage SKODA_HVBAT_MOD3_C5_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 cell 6 state of charge SKODA_HVBAT_MOD3_C6_SOC

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 3 cell 6 voltage SKODA_HVBAT_MOD3_C6_V

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 3 id SKODA_HVBAT_MOD3_ID

  • Service 22DID 1852
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 4 cell 1 state of charge SKODA_HVBAT_MOD4_C1_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 1 voltage SKODA_HVBAT_MOD4_C1_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 cell 2 state of charge SKODA_HVBAT_MOD4_C2_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 2 voltage SKODA_HVBAT_MOD4_C2_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 cell 3 state of charge SKODA_HVBAT_MOD4_C3_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 3 voltage SKODA_HVBAT_MOD4_C3_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 cell 4 state of charge SKODA_HVBAT_MOD4_C4_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 4 voltage SKODA_HVBAT_MOD4_C4_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 cell 5 state of charge SKODA_HVBAT_MOD4_C5_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 5 voltage SKODA_HVBAT_MOD4_C5_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 cell 6 state of charge SKODA_HVBAT_MOD4_C6_SOC

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 4 cell 6 voltage SKODA_HVBAT_MOD4_C6_V

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 4 id SKODA_HVBAT_MOD4_ID

  • Service 22DID 1853
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 5 cell 1 state of charge SKODA_HVBAT_MOD5_C1_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 1 voltage SKODA_HVBAT_MOD5_C1_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 cell 2 state of charge SKODA_HVBAT_MOD5_C2_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 2 voltage SKODA_HVBAT_MOD5_C2_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 cell 3 state of charge SKODA_HVBAT_MOD5_C3_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 3 voltage SKODA_HVBAT_MOD5_C3_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 cell 4 state of charge SKODA_HVBAT_MOD5_C4_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 4 voltage SKODA_HVBAT_MOD5_C4_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 cell 5 state of charge SKODA_HVBAT_MOD5_C5_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 5 voltage SKODA_HVBAT_MOD5_C5_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 cell 6 state of charge SKODA_HVBAT_MOD5_C6_SOC

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 5 cell 6 voltage SKODA_HVBAT_MOD5_C6_V

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 5 id SKODA_HVBAT_MOD5_ID

  • Service 22DID 1854
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 6 cell 1 state of charge SKODA_HVBAT_MOD6_C1_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 1 voltage SKODA_HVBAT_MOD6_C1_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 cell 2 state of charge SKODA_HVBAT_MOD6_C2_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 2 voltage SKODA_HVBAT_MOD6_C2_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 cell 3 state of charge SKODA_HVBAT_MOD6_C3_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 3 voltage SKODA_HVBAT_MOD6_C3_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 cell 4 state of charge SKODA_HVBAT_MOD6_C4_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 4 voltage SKODA_HVBAT_MOD6_C4_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 cell 5 state of charge SKODA_HVBAT_MOD6_C5_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 5 voltage SKODA_HVBAT_MOD6_C5_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 cell 6 state of charge SKODA_HVBAT_MOD6_C6_SOC

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 6 cell 6 voltage SKODA_HVBAT_MOD6_C6_V

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 6 id SKODA_HVBAT_MOD6_ID

  • Service 22DID 1855
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 7 cell 1 state of charge SKODA_HVBAT_MOD7_C1_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 1 voltage SKODA_HVBAT_MOD7_C1_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 cell 2 state of charge SKODA_HVBAT_MOD7_C2_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 2 voltage SKODA_HVBAT_MOD7_C2_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 cell 3 state of charge SKODA_HVBAT_MOD7_C3_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 3 voltage SKODA_HVBAT_MOD7_C3_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 cell 4 state of charge SKODA_HVBAT_MOD7_C4_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 4 voltage SKODA_HVBAT_MOD7_C4_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 cell 5 state of charge SKODA_HVBAT_MOD7_C5_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 5 voltage SKODA_HVBAT_MOD7_C5_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 cell 6 state of charge SKODA_HVBAT_MOD7_C6_SOC

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 7 cell 6 voltage SKODA_HVBAT_MOD7_C6_V

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 7 id SKODA_HVBAT_MOD7_ID

  • Service 22DID 1856
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 8 cell 1 state of charge SKODA_HVBAT_MOD8_C1_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 1 voltage SKODA_HVBAT_MOD8_C1_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 cell 2 state of charge SKODA_HVBAT_MOD8_C2_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 2 voltage SKODA_HVBAT_MOD8_C2_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 cell 3 state of charge SKODA_HVBAT_MOD8_C3_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 3 voltage SKODA_HVBAT_MOD8_C3_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 cell 4 state of charge SKODA_HVBAT_MOD8_C4_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 4 voltage SKODA_HVBAT_MOD8_C4_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 cell 5 state of charge SKODA_HVBAT_MOD8_C5_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 5 voltage SKODA_HVBAT_MOD8_C5_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 cell 6 state of charge SKODA_HVBAT_MOD8_C6_SOC

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 8 cell 6 voltage SKODA_HVBAT_MOD8_C6_V

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 8 id SKODA_HVBAT_MOD8_ID

  • Service 22DID 1857
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 9 cell 1 state of charge SKODA_HVBAT_MOD9_C1_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 1 voltage SKODA_HVBAT_MOD9_C1_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 cell 2 state of charge SKODA_HVBAT_MOD9_C2_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 2 voltage SKODA_HVBAT_MOD9_C2_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 cell 3 state of charge SKODA_HVBAT_MOD9_C3_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 3 voltage SKODA_HVBAT_MOD9_C3_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 cell 4 state of charge SKODA_HVBAT_MOD9_C4_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 4 voltage SKODA_HVBAT_MOD9_C4_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 cell 5 state of charge SKODA_HVBAT_MOD9_C5_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 5 voltage SKODA_HVBAT_MOD9_C5_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 cell 6 state of charge SKODA_HVBAT_MOD9_C6_SOC

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 9 cell 6 voltage SKODA_HVBAT_MOD9_C6_V

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 9 id SKODA_HVBAT_MOD9_ID

  • Service 22DID 1858
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 10 cell 1 state of charge SKODA_HVBAT_MOD10_C1_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 1 voltage SKODA_HVBAT_MOD10_C1_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 cell 2 state of charge SKODA_HVBAT_MOD10_C2_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 2 voltage SKODA_HVBAT_MOD10_C2_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 cell 3 state of charge SKODA_HVBAT_MOD10_C3_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 3 voltage SKODA_HVBAT_MOD10_C3_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 cell 4 state of charge SKODA_HVBAT_MOD10_C4_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 4 voltage SKODA_HVBAT_MOD10_C4_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 cell 5 state of charge SKODA_HVBAT_MOD10_C5_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 5 voltage SKODA_HVBAT_MOD10_C5_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 cell 6 state of charge SKODA_HVBAT_MOD10_C6_SOC

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 10 cell 6 voltage SKODA_HVBAT_MOD10_C6_V

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 10 id SKODA_HVBAT_MOD10_ID

  • Service 22DID 1859
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 11 cell 1 state of charge SKODA_HVBAT_MOD11_C1_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 1 voltage SKODA_HVBAT_MOD11_C1_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 cell 2 state of charge SKODA_HVBAT_MOD11_C2_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 2 voltage SKODA_HVBAT_MOD11_C2_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 cell 3 state of charge SKODA_HVBAT_MOD11_C3_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 3 voltage SKODA_HVBAT_MOD11_C3_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 cell 4 state of charge SKODA_HVBAT_MOD11_C4_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 4 voltage SKODA_HVBAT_MOD11_C4_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 cell 5 state of charge SKODA_HVBAT_MOD11_C5_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 5 voltage SKODA_HVBAT_MOD11_C5_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 cell 6 state of charge SKODA_HVBAT_MOD11_C6_SOC

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 11 cell 6 voltage SKODA_HVBAT_MOD11_C6_V

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 11 id SKODA_HVBAT_MOD11_ID

  • Service 22DID 185A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 12 cell 1 state of charge SKODA_HVBAT_MOD12_C1_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 1 voltage SKODA_HVBAT_MOD12_C1_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 cell 2 state of charge SKODA_HVBAT_MOD12_C2_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 2 voltage SKODA_HVBAT_MOD12_C2_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 cell 3 state of charge SKODA_HVBAT_MOD12_C3_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 3 voltage SKODA_HVBAT_MOD12_C3_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 cell 4 state of charge SKODA_HVBAT_MOD12_C4_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 4 voltage SKODA_HVBAT_MOD12_C4_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 cell 5 state of charge SKODA_HVBAT_MOD12_C5_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 5 voltage SKODA_HVBAT_MOD12_C5_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 cell 6 state of charge SKODA_HVBAT_MOD12_C6_SOC

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 12 cell 6 voltage SKODA_HVBAT_MOD12_C6_V

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 12 id SKODA_HVBAT_MOD12_ID

  • Service 22DID 185B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 13 cell 1 state of charge SKODA_HVBAT_MOD13_C1_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 1 voltage SKODA_HVBAT_MOD13_C1_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 cell 2 state of charge SKODA_HVBAT_MOD13_C2_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 2 voltage SKODA_HVBAT_MOD13_C2_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 cell 3 state of charge SKODA_HVBAT_MOD13_C3_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 3 voltage SKODA_HVBAT_MOD13_C3_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 cell 4 state of charge SKODA_HVBAT_MOD13_C4_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 4 voltage SKODA_HVBAT_MOD13_C4_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 cell 5 state of charge SKODA_HVBAT_MOD13_C5_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 5 voltage SKODA_HVBAT_MOD13_C5_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 cell 6 state of charge SKODA_HVBAT_MOD13_C6_SOC

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 13 cell 6 voltage SKODA_HVBAT_MOD13_C6_V

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 13 id SKODA_HVBAT_MOD13_ID

  • Service 22DID 185C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 14 cell 1 state of charge SKODA_HVBAT_MOD14_C1_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 1 voltage SKODA_HVBAT_MOD14_C1_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 cell 2 state of charge SKODA_HVBAT_MOD14_C2_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 2 voltage SKODA_HVBAT_MOD14_C2_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 cell 3 state of charge SKODA_HVBAT_MOD14_C3_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 3 voltage SKODA_HVBAT_MOD14_C3_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 cell 4 state of charge SKODA_HVBAT_MOD14_C4_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 4 voltage SKODA_HVBAT_MOD14_C4_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 cell 5 state of charge SKODA_HVBAT_MOD14_C5_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 5 voltage SKODA_HVBAT_MOD14_C5_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 cell 6 state of charge SKODA_HVBAT_MOD14_C6_SOC

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 14 cell 6 voltage SKODA_HVBAT_MOD14_C6_V

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 14 id SKODA_HVBAT_MOD14_ID

  • Service 22DID 185D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 15 cell 1 state of charge SKODA_HVBAT_MOD15_C1_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 1 voltage SKODA_HVBAT_MOD15_C1_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 cell 2 state of charge SKODA_HVBAT_MOD15_C2_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 2 voltage SKODA_HVBAT_MOD15_C2_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 cell 3 state of charge SKODA_HVBAT_MOD15_C3_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 3 voltage SKODA_HVBAT_MOD15_C3_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 cell 4 state of charge SKODA_HVBAT_MOD15_C4_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 4 voltage SKODA_HVBAT_MOD15_C4_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 cell 5 state of charge SKODA_HVBAT_MOD15_C5_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 5 voltage SKODA_HVBAT_MOD15_C5_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 cell 6 state of charge SKODA_HVBAT_MOD15_C6_SOC

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 15 cell 6 voltage SKODA_HVBAT_MOD15_C6_V

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 15 id SKODA_HVBAT_MOD15_ID

  • Service 22DID 185E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 16 cell 1 state of charge SKODA_HVBAT_MOD16_C1_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 1 voltage SKODA_HVBAT_MOD16_C1_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 cell 2 state of charge SKODA_HVBAT_MOD16_C2_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 2 voltage SKODA_HVBAT_MOD16_C2_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 cell 3 state of charge SKODA_HVBAT_MOD16_C3_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 3 voltage SKODA_HVBAT_MOD16_C3_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 cell 4 state of charge SKODA_HVBAT_MOD16_C4_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 4 voltage SKODA_HVBAT_MOD16_C4_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 cell 5 state of charge SKODA_HVBAT_MOD16_C5_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 5 voltage SKODA_HVBAT_MOD16_C5_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 cell 6 state of charge SKODA_HVBAT_MOD16_C6_SOC

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 16 cell 6 voltage SKODA_HVBAT_MOD16_C6_V

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 16 id SKODA_HVBAT_MOD16_ID

  • Service 22DID 185F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 17 cell 1 state of charge SKODA_HVBAT_MOD17_C1_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 1 voltage SKODA_HVBAT_MOD17_C1_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 cell 2 state of charge SKODA_HVBAT_MOD17_C2_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 2 voltage SKODA_HVBAT_MOD17_C2_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 cell 3 state of charge SKODA_HVBAT_MOD17_C3_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 3 voltage SKODA_HVBAT_MOD17_C3_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 cell 4 state of charge SKODA_HVBAT_MOD17_C4_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 4 voltage SKODA_HVBAT_MOD17_C4_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 cell 5 state of charge SKODA_HVBAT_MOD17_C5_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 5 voltage SKODA_HVBAT_MOD17_C5_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 cell 6 state of charge SKODA_HVBAT_MOD17_C6_SOC

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 17 cell 6 voltage SKODA_HVBAT_MOD17_C6_V

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 17 id SKODA_HVBAT_MOD17_ID

  • Service 22DID 1860
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 18 cell 1 state of charge SKODA_HVBAT_MOD18_C1_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 1 voltage SKODA_HVBAT_MOD18_C1_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 cell 2 state of charge SKODA_HVBAT_MOD18_C2_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 2 voltage SKODA_HVBAT_MOD18_C2_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 cell 3 state of charge SKODA_HVBAT_MOD18_C3_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 3 voltage SKODA_HVBAT_MOD18_C3_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 cell 4 state of charge SKODA_HVBAT_MOD18_C4_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 4 voltage SKODA_HVBAT_MOD18_C4_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 cell 5 state of charge SKODA_HVBAT_MOD18_C5_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 5 voltage SKODA_HVBAT_MOD18_C5_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 cell 6 state of charge SKODA_HVBAT_MOD18_C6_SOC

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 18 cell 6 voltage SKODA_HVBAT_MOD18_C6_V

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 18 id SKODA_HVBAT_MOD18_ID

  • Service 22DID 1861
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 19 cell 1 state of charge SKODA_HVBAT_MOD19_C1_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 1 voltage SKODA_HVBAT_MOD19_C1_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 cell 2 state of charge SKODA_HVBAT_MOD19_C2_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 2 voltage SKODA_HVBAT_MOD19_C2_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 cell 3 state of charge SKODA_HVBAT_MOD19_C3_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 3 voltage SKODA_HVBAT_MOD19_C3_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 cell 4 state of charge SKODA_HVBAT_MOD19_C4_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 4 voltage SKODA_HVBAT_MOD19_C4_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 cell 5 state of charge SKODA_HVBAT_MOD19_C5_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 5 voltage SKODA_HVBAT_MOD19_C5_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 cell 6 state of charge SKODA_HVBAT_MOD19_C6_SOC

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 19 cell 6 voltage SKODA_HVBAT_MOD19_C6_V

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 19 id SKODA_HVBAT_MOD19_ID

  • Service 22DID 1862
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 20 cell 1 state of charge SKODA_HVBAT_MOD20_C1_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 1 voltage SKODA_HVBAT_MOD20_C1_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 cell 2 state of charge SKODA_HVBAT_MOD20_C2_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 2 voltage SKODA_HVBAT_MOD20_C2_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 cell 3 state of charge SKODA_HVBAT_MOD20_C3_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 3 voltage SKODA_HVBAT_MOD20_C3_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 cell 4 state of charge SKODA_HVBAT_MOD20_C4_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 4 voltage SKODA_HVBAT_MOD20_C4_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 cell 5 state of charge SKODA_HVBAT_MOD20_C5_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 5 voltage SKODA_HVBAT_MOD20_C5_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 cell 6 state of charge SKODA_HVBAT_MOD20_C6_SOC

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 20 cell 6 voltage SKODA_HVBAT_MOD20_C6_V

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 20 id SKODA_HVBAT_MOD20_ID

  • Service 22DID 1863
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 21 cell 1 state of charge SKODA_HVBAT_MOD21_C1_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 1 voltage SKODA_HVBAT_MOD21_C1_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 cell 2 state of charge SKODA_HVBAT_MOD21_C2_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 2 voltage SKODA_HVBAT_MOD21_C2_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 cell 3 state of charge SKODA_HVBAT_MOD21_C3_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 3 voltage SKODA_HVBAT_MOD21_C3_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 cell 4 state of charge SKODA_HVBAT_MOD21_C4_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 4 voltage SKODA_HVBAT_MOD21_C4_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 cell 5 state of charge SKODA_HVBAT_MOD21_C5_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 5 voltage SKODA_HVBAT_MOD21_C5_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 cell 6 state of charge SKODA_HVBAT_MOD21_C6_SOC

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 21 cell 6 voltage SKODA_HVBAT_MOD21_C6_V

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 21 id SKODA_HVBAT_MOD21_ID

  • Service 22DID 1864
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 22 cell 1 state of charge SKODA_HVBAT_MOD22_C1_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 1 voltage SKODA_HVBAT_MOD22_C1_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 cell 2 state of charge SKODA_HVBAT_MOD22_C2_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 2 voltage SKODA_HVBAT_MOD22_C2_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 cell 3 state of charge SKODA_HVBAT_MOD22_C3_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 3 voltage SKODA_HVBAT_MOD22_C3_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 cell 4 state of charge SKODA_HVBAT_MOD22_C4_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 4 voltage SKODA_HVBAT_MOD22_C4_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 cell 5 state of charge SKODA_HVBAT_MOD22_C5_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 5 voltage SKODA_HVBAT_MOD22_C5_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 cell 6 state of charge SKODA_HVBAT_MOD22_C6_SOC

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 22 cell 6 voltage SKODA_HVBAT_MOD22_C6_V

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 22 id SKODA_HVBAT_MOD22_ID

  • Service 22DID 1865
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 23 cell 1 state of charge SKODA_HVBAT_MOD23_C1_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 1 voltage SKODA_HVBAT_MOD23_C1_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 cell 2 state of charge SKODA_HVBAT_MOD23_C2_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 2 voltage SKODA_HVBAT_MOD23_C2_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 cell 3 state of charge SKODA_HVBAT_MOD23_C3_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 3 voltage SKODA_HVBAT_MOD23_C3_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 cell 4 state of charge SKODA_HVBAT_MOD23_C4_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 4 voltage SKODA_HVBAT_MOD23_C4_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 cell 5 state of charge SKODA_HVBAT_MOD23_C5_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 5 voltage SKODA_HVBAT_MOD23_C5_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 cell 6 state of charge SKODA_HVBAT_MOD23_C6_SOC

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 23 cell 6 voltage SKODA_HVBAT_MOD23_C6_V

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 23 id SKODA_HVBAT_MOD23_ID

  • Service 22DID 1866
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 24 cell 1 state of charge SKODA_HVBAT_MOD24_C1_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 1 voltage SKODA_HVBAT_MOD24_C1_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 cell 2 state of charge SKODA_HVBAT_MOD24_C2_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 2 voltage SKODA_HVBAT_MOD24_C2_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 cell 3 state of charge SKODA_HVBAT_MOD24_C3_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 3 voltage SKODA_HVBAT_MOD24_C3_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 cell 4 state of charge SKODA_HVBAT_MOD24_C4_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 4 voltage SKODA_HVBAT_MOD24_C4_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 cell 5 state of charge SKODA_HVBAT_MOD24_C5_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 5 voltage SKODA_HVBAT_MOD24_C5_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 cell 6 state of charge SKODA_HVBAT_MOD24_C6_SOC

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 24 cell 6 voltage SKODA_HVBAT_MOD24_C6_V

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 24 id SKODA_HVBAT_MOD24_ID

  • Service 22DID 1867
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 25 cell 1 state of charge SKODA_HVBAT_MOD25_C1_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 1 voltage SKODA_HVBAT_MOD25_C1_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 cell 2 state of charge SKODA_HVBAT_MOD25_C2_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 2 voltage SKODA_HVBAT_MOD25_C2_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 cell 3 state of charge SKODA_HVBAT_MOD25_C3_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 3 voltage SKODA_HVBAT_MOD25_C3_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 cell 4 state of charge SKODA_HVBAT_MOD25_C4_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 4 voltage SKODA_HVBAT_MOD25_C4_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 cell 5 state of charge SKODA_HVBAT_MOD25_C5_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 5 voltage SKODA_HVBAT_MOD25_C5_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 cell 6 state of charge SKODA_HVBAT_MOD25_C6_SOC

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 25 cell 6 voltage SKODA_HVBAT_MOD25_C6_V

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 25 id SKODA_HVBAT_MOD25_ID

  • Service 22DID 1868
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 26 cell 1 state of charge SKODA_HVBAT_MOD26_C1_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 1 voltage SKODA_HVBAT_MOD26_C1_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 cell 2 state of charge SKODA_HVBAT_MOD26_C2_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 2 voltage SKODA_HVBAT_MOD26_C2_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 cell 3 state of charge SKODA_HVBAT_MOD26_C3_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 3 voltage SKODA_HVBAT_MOD26_C3_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 cell 4 state of charge SKODA_HVBAT_MOD26_C4_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 4 voltage SKODA_HVBAT_MOD26_C4_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 cell 5 state of charge SKODA_HVBAT_MOD26_C5_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 5 voltage SKODA_HVBAT_MOD26_C5_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 cell 6 state of charge SKODA_HVBAT_MOD26_C6_SOC

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 26 cell 6 voltage SKODA_HVBAT_MOD26_C6_V

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 26 id SKODA_HVBAT_MOD26_ID

  • Service 22DID 1869
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 27 cell 1 state of charge SKODA_HVBAT_MOD27_C1_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 1 voltage SKODA_HVBAT_MOD27_C1_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 cell 2 state of charge SKODA_HVBAT_MOD27_C2_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 2 voltage SKODA_HVBAT_MOD27_C2_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 cell 3 state of charge SKODA_HVBAT_MOD27_C3_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 3 voltage SKODA_HVBAT_MOD27_C3_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 cell 4 state of charge SKODA_HVBAT_MOD27_C4_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 4 voltage SKODA_HVBAT_MOD27_C4_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 cell 5 state of charge SKODA_HVBAT_MOD27_C5_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 5 voltage SKODA_HVBAT_MOD27_C5_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 cell 6 state of charge SKODA_HVBAT_MOD27_C6_SOC

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 27 cell 6 voltage SKODA_HVBAT_MOD27_C6_V

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 27 id SKODA_HVBAT_MOD27_ID

  • Service 22DID 186A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 28 cell 1 state of charge SKODA_HVBAT_MOD28_C1_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 1 voltage SKODA_HVBAT_MOD28_C1_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 cell 2 state of charge SKODA_HVBAT_MOD28_C2_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 2 voltage SKODA_HVBAT_MOD28_C2_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 cell 3 state of charge SKODA_HVBAT_MOD28_C3_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 3 voltage SKODA_HVBAT_MOD28_C3_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 cell 4 state of charge SKODA_HVBAT_MOD28_C4_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 4 voltage SKODA_HVBAT_MOD28_C4_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 cell 5 state of charge SKODA_HVBAT_MOD28_C5_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 5 voltage SKODA_HVBAT_MOD28_C5_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 cell 6 state of charge SKODA_HVBAT_MOD28_C6_SOC

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 28 cell 6 voltage SKODA_HVBAT_MOD28_C6_V

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 28 id SKODA_HVBAT_MOD28_ID

  • Service 22DID 186B
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 29 cell 1 state of charge SKODA_HVBAT_MOD29_C1_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 1 voltage SKODA_HVBAT_MOD29_C1_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 cell 2 state of charge SKODA_HVBAT_MOD29_C2_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 2 voltage SKODA_HVBAT_MOD29_C2_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 cell 3 state of charge SKODA_HVBAT_MOD29_C3_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 3 voltage SKODA_HVBAT_MOD29_C3_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 cell 4 state of charge SKODA_HVBAT_MOD29_C4_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 4 voltage SKODA_HVBAT_MOD29_C4_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 cell 5 state of charge SKODA_HVBAT_MOD29_C5_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 5 voltage SKODA_HVBAT_MOD29_C5_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 cell 6 state of charge SKODA_HVBAT_MOD29_C6_SOC

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 29 cell 6 voltage SKODA_HVBAT_MOD29_C6_V

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 29 id SKODA_HVBAT_MOD29_ID

  • Service 22DID 186C
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 30 cell 1 state of charge SKODA_HVBAT_MOD30_C1_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 1 voltage SKODA_HVBAT_MOD30_C1_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 cell 2 state of charge SKODA_HVBAT_MOD30_C2_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 2 voltage SKODA_HVBAT_MOD30_C2_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 cell 3 state of charge SKODA_HVBAT_MOD30_C3_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 3 voltage SKODA_HVBAT_MOD30_C3_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 cell 4 state of charge SKODA_HVBAT_MOD30_C4_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 4 voltage SKODA_HVBAT_MOD30_C4_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 cell 5 state of charge SKODA_HVBAT_MOD30_C5_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 5 voltage SKODA_HVBAT_MOD30_C5_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 cell 6 state of charge SKODA_HVBAT_MOD30_C6_SOC

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 30 cell 6 voltage SKODA_HVBAT_MOD30_C6_V

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 30 id SKODA_HVBAT_MOD30_ID

  • Service 22DID 186D
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 31 cell 1 state of charge SKODA_HVBAT_MOD31_C1_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 1 voltage SKODA_HVBAT_MOD31_C1_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 cell 2 state of charge SKODA_HVBAT_MOD31_C2_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 2 voltage SKODA_HVBAT_MOD31_C2_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 cell 3 state of charge SKODA_HVBAT_MOD31_C3_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 3 voltage SKODA_HVBAT_MOD31_C3_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 cell 4 state of charge SKODA_HVBAT_MOD31_C4_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 4 voltage SKODA_HVBAT_MOD31_C4_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 cell 5 state of charge SKODA_HVBAT_MOD31_C5_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 5 voltage SKODA_HVBAT_MOD31_C5_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 cell 6 state of charge SKODA_HVBAT_MOD31_C6_SOC

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 31 cell 6 voltage SKODA_HVBAT_MOD31_C6_V

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 31 id SKODA_HVBAT_MOD31_ID

  • Service 22DID 186E
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 31 id SKODA_HVBAT_MOD33_ID

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 32 cell 1 state of charge SKODA_HVBAT_MOD32_C1_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 1 voltage SKODA_HVBAT_MOD32_C1_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 cell 2 state of charge SKODA_HVBAT_MOD32_C2_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 2 voltage SKODA_HVBAT_MOD32_C2_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 cell 3 state of charge SKODA_HVBAT_MOD32_C3_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 3 voltage SKODA_HVBAT_MOD32_C3_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 cell 4 state of charge SKODA_HVBAT_MOD32_C4_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 4 voltage SKODA_HVBAT_MOD32_C4_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 cell 5 state of charge SKODA_HVBAT_MOD32_C5_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 5 voltage SKODA_HVBAT_MOD32_C5_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 cell 6 state of charge SKODA_HVBAT_MOD32_C6_SOC

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 32 cell 6 voltage SKODA_HVBAT_MOD32_C6_V

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 32 id SKODA_HVBAT_MOD32_ID

  • Service 22DID 186F
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

HV battery module 33 cell 1 state of charge SKODA_HVBAT_MOD33_C1_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 1 voltage SKODA_HVBAT_MOD33_C1_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 33 cell 2 state of charge SKODA_HVBAT_MOD33_C2_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 2 voltage SKODA_HVBAT_MOD33_C2_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 33 cell 3 state of charge SKODA_HVBAT_MOD33_C3_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 3 voltage SKODA_HVBAT_MOD33_C3_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 33 cell 4 state of charge SKODA_HVBAT_MOD33_C4_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 4 voltage SKODA_HVBAT_MOD33_C4_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 33 cell 5 state of charge SKODA_HVBAT_MOD33_C5_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 5 voltage SKODA_HVBAT_MOD33_C5_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

HV battery module 33 cell 6 state of charge SKODA_HVBAT_MOD33_C6_SOC

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

HV battery module 33 cell 6 voltage SKODA_HVBAT_MOD33_C6_V

  • Service 22DID 1870
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5 V
Unit
V

In testing for 2001 to 2026.

Internal

Average battery consumption SKODA_HVBAT_CSMP_AVG_INT

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

Estimated electric power reserve SKODA_RANGE_EST_INT

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Modules

HV battery module temperature, #5 SKODA_HVBAT_MOD_T_5

  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #6 SKODA_HVBAT_MOD_T_6

  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #7 SKODA_HVBAT_MOD_T_7

  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #8 SKODA_HVBAT_MOD_T_8

  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #9 SKODA_HVBAT_MOD_T_9

  • Service 22DID 1EB6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #10 SKODA_HVBAT_MOD_T_10

  • Service 22DID 1EB7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #11 SKODA_HVBAT_MOD_T_11

  • Service 22DID 1EB8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #12 SKODA_HVBAT_MOD_T_12

  • Service 22DID 1EB9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #13 SKODA_HVBAT_MOD_T_13

  • Service 22DID 1EBA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #14 SKODA_HVBAT_MOD_T_14

  • Service 22DID 1EBB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #15 SKODA_HVBAT_MOD_T_15

  • Service 22DID 1EBC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

HV battery module temperature, #16 SKODA_HVBAT_MOD_T_16

  • Service 22DID 1EBD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

In testing for 2001 to 2026.

Module 1, temperature 1 SKODA_HVBAT_MOD1_T1

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 1, temperature 2 SKODA_HVBAT_MOD1_T2

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 1, temperature 3 SKODA_HVBAT_MOD1_T3

  • Service 22DID 1821
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 2, temperature 1 SKODA_HVBAT_MOD2_T1

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 2, temperature 2 SKODA_HVBAT_MOD2_T2

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 2, temperature 3 SKODA_HVBAT_MOD2_T3

  • Service 22DID 1822
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 3, temperature 1 SKODA_HVBAT_MOD3_T1

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 3, temperature 2 SKODA_HVBAT_MOD3_T2

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 3, temperature 3 SKODA_HVBAT_MOD3_T3

  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 4, temperature 1 SKODA_HVBAT_MOD4_T1

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 4, temperature 2 SKODA_HVBAT_MOD4_T2

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 4, temperature 3 SKODA_HVBAT_MOD4_T3

  • Service 22DID 1824
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 5, temperature 1 SKODA_HVBAT_MOD5_T1

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 5, temperature 2 SKODA_HVBAT_MOD5_T2

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 5, temperature 3 SKODA_HVBAT_MOD5_T3

  • Service 22DID 1825
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 6, temperature 1 SKODA_HVBAT_MOD6_T1

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 6, temperature 2 SKODA_HVBAT_MOD6_T2

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 6, temperature 3 SKODA_HVBAT_MOD6_T3

  • Service 22DID 1826
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 7, temperature 1 SKODA_HVBAT_MOD7_T1

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 7, temperature 2 SKODA_HVBAT_MOD7_T2

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 7, temperature 3 SKODA_HVBAT_MOD7_T3

  • Service 22DID 1827
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 8, temperature 1 SKODA_HVBAT_MOD8_T1

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 8, temperature 2 SKODA_HVBAT_MOD8_T2

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 8, temperature 3 SKODA_HVBAT_MOD8_T3

  • Service 22DID 1828
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 9, temperature 1 SKODA_HVBAT_MOD9_T1

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 9, temperature 2 SKODA_HVBAT_MOD9_T2

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 9, temperature 3 SKODA_HVBAT_MOD9_T3

  • Service 22DID 1829
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 10, temperature 1 SKODA_HVBAT_MOD10_T1

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 10, temperature 2 SKODA_HVBAT_MOD10_T2

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 10, temperature 3 SKODA_HVBAT_MOD10_T3

  • Service 22DID 182A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 11, temperature 1 SKODA_HVBAT_MOD11_T1

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 11, temperature 2 SKODA_HVBAT_MOD11_T2

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 11, temperature 3 SKODA_HVBAT_MOD11_T3

  • Service 22DID 182B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 12, temperature 1 SKODA_HVBAT_MOD12_T1

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 12, temperature 2 SKODA_HVBAT_MOD12_T2

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 12, temperature 3 SKODA_HVBAT_MOD12_T3

  • Service 22DID 182C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 13, temperature 1 SKODA_HVBAT_MOD13_T1

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 13, temperature 2 SKODA_HVBAT_MOD13_T2

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 13, temperature 3 SKODA_HVBAT_MOD13_T3

  • Service 22DID 182D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 14, temperature 1 SKODA_HVBAT_MOD14_T1

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 14, temperature 2 SKODA_HVBAT_MOD14_T2

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 14, temperature 3 SKODA_HVBAT_MOD14_T3

  • Service 22DID 182E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 15, temperature 1 SKODA_HVBAT_MOD15_T1

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 15, temperature 2 SKODA_HVBAT_MOD15_T2

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 15, temperature 3 SKODA_HVBAT_MOD15_T3

  • Service 22DID 182F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 16, temperature 1 SKODA_HVBAT_MOD16_T1

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 16, temperature 2 SKODA_HVBAT_MOD16_T2

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 16, temperature 3 SKODA_HVBAT_MOD16_T3

  • Service 22DID 1830
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 17, temperature 1 SKODA_HVBAT_MOD17_T1

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 17, temperature 2 SKODA_HVBAT_MOD17_T2

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 17, temperature 3 SKODA_HVBAT_MOD17_T3

  • Service 22DID 1831
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 18, temperature 1 SKODA_HVBAT_MOD18_T1

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 18, temperature 2 SKODA_HVBAT_MOD18_T2

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 18, temperature 3 SKODA_HVBAT_MOD18_T3

  • Service 22DID 1832
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 19, temperature 1 SKODA_HVBAT_MOD19_T1

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 19, temperature 2 SKODA_HVBAT_MOD19_T2

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 19, temperature 3 SKODA_HVBAT_MOD19_T3

  • Service 22DID 1833
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 20, temperature 1 SKODA_HVBAT_MOD20_T1

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 20, temperature 2 SKODA_HVBAT_MOD20_T2

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 20, temperature 3 SKODA_HVBAT_MOD20_T3

  • Service 22DID 1834
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 21, temperature 1 SKODA_HVBAT_MOD21_T1

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 21, temperature 2 SKODA_HVBAT_MOD21_T2

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 21, temperature 3 SKODA_HVBAT_MOD21_T3

  • Service 22DID 1835
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 22, temperature 1 SKODA_HVBAT_MOD22_T1

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 22, temperature 2 SKODA_HVBAT_MOD22_T2

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 22, temperature 3 SKODA_HVBAT_MOD22_T3

  • Service 22DID 1836
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 23, temperature 1 SKODA_HVBAT_MOD23_T1

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 23, temperature 2 SKODA_HVBAT_MOD23_T2

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 23, temperature 3 SKODA_HVBAT_MOD23_T3

  • Service 22DID 1837
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 24, temperature 1 SKODA_HVBAT_MOD24_T1

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 24, temperature 2 SKODA_HVBAT_MOD24_T2

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 24, temperature 3 SKODA_HVBAT_MOD24_T3

  • Service 22DID 1838
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 25, temperature 1 SKODA_HVBAT_MOD25_T1

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 25, temperature 2 SKODA_HVBAT_MOD25_T2

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 25, temperature 3 SKODA_HVBAT_MOD25_T3

  • Service 22DID 1839
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 26, temperature 1 SKODA_HVBAT_MOD26_T1

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 26, temperature 2 SKODA_HVBAT_MOD26_T2

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 26, temperature 3 SKODA_HVBAT_MOD26_T3

  • Service 22DID 183A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 27, temperature 1 SKODA_HVBAT_MOD27_T1

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 27, temperature 2 SKODA_HVBAT_MOD27_T2

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 27, temperature 3 SKODA_HVBAT_MOD27_T3

  • Service 22DID 183B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 28, temperature 1 SKODA_HVBAT_MOD28_T1

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 28, temperature 2 SKODA_HVBAT_MOD28_T2

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 28, temperature 3 SKODA_HVBAT_MOD28_T3

  • Service 22DID 183C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 29, temperature 1 SKODA_HVBAT_MOD29_T1

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 29, temperature 2 SKODA_HVBAT_MOD29_T2

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 29, temperature 3 SKODA_HVBAT_MOD29_T3

  • Service 22DID 183D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 30, temperature 1 SKODA_HVBAT_MOD30_T1

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 30, temperature 2 SKODA_HVBAT_MOD30_T2

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 30, temperature 3 SKODA_HVBAT_MOD30_T3

  • Service 22DID 183E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 31, temperature 1 SKODA_HVBAT_MOD31_T1

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 31, temperature 2 SKODA_HVBAT_MOD31_T2

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 31, temperature 3 SKODA_HVBAT_MOD31_T3

  • Service 22DID 183F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 32, temperature 1 SKODA_HVBAT_MOD32_T1

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 32, temperature 2 SKODA_HVBAT_MOD32_T2

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 32, temperature 3 SKODA_HVBAT_MOD32_T3

  • Service 22DID 1840
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 33, temperature 1 SKODA_HVBAT_MOD33_T1

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 33, temperature 2 SKODA_HVBAT_MOD33_T2

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Module 33, temperature 3 SKODA_HVBAT_MOD33_T3

  • Service 22DID 1841
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Brakes

Brake disk drying active SKODA_BRK_DRY_ACT

  • Service 22DID 180E
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Brake disk drying last activation distance SKODA_BRK_DRY_ODO_LAST

  • Service 22DID 180E
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Brake pressure SKODA_BRK_PRESS

  • Service 22DID 1816
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Climate

A/C compressor load SKODA_HVAC_AC_LOAD

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

A/C compressor power, actual SKODA_AC_CMPR_PWR_ACT

  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2001 to 2026.

A/C compressor power, actual SKODA_AC_COMPRESSOR_PWR_ACT

  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2001 to 2026.

A/c compressor torque, requested SKODA_AC_COMP_T

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

A/C refrigerant pressure, sensor 1 SKODA_AC_REFRIG_P_SENS1

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8810000
Range
0 to 576.708 bar
Unit
bar

In testing for 2001 to 2026.

A/C refrigerant temperature, sensor 1 SKODA_AC_REFRIG_T_SENS1

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2001 to 2026.

A/C refrigerant temperature, sensor 1 interior SKODA_AC_REFRIG_T_SENS1_INT

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2001 to 2026.

Air conditioning compressor power consumption SKODA_AC_COMP_PWR

  • Service 22DID 27D6
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val25
Range
0 to 10.2 kW
Unit
kW

In testing for 2001 to 2026.

Air conditioning compressor shutdown requirement SKODA_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Air conditioning compressor torque SKODA_PQ35_AC_COMP_TRQ

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Air conditioning refrigerant pressure SKODA_AC_REFRIG_P

  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

In testing for 2001 to 2026.

Air pollution level SKODA_AIR_POLUTION

0 means clean air.

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.7 to 12.7
Unit
Number

In testing for 2001 to 2026.

Ambient air temperature SKODA_AAT

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
0 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Ambient air temperature SKODA_AAT_V2

  • Service 22DID F446
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Ambient air temperature SKODA_AAT_V4

  • Service 22DID F446
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Ambient air temperature, cluster SKODA_DASH_AAT

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Barometric pressure SKODA_BARO

  • Service 22DID F433
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2001 to 2026.

CO2 content interior SKODA_CABIN_CO2

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

In testing for 2001 to 2026.

CO2 content interior SKODA_CO2_CONTENT_INTERIOR

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

In testing for 2001 to 2026.

Evaporator output temperature SKODA_HVAC_EVAP_T

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Front left temperature flap actual SKODA_FL_T_FLAP_ACT

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Front right temperature flap actual SKODA_FR_T_FLAP_ACT

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Inside humidity SKODA_HVAC_INSIDE_HUM

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Interior air temperature SKODA_IAT

  • Service 22DID 2613
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Leg air vent temperature SKODA_LEG_DEFL_T

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Outside humidity SKODA_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Outside temperature SKODA_AAT_746

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature SKODA_AAT_V2_V2

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature SKODA_AAT_V3

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature SKODA_PTC_OUTSIDE_T

  • Service 22DID 2609
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature SKODA_TRON_AAT

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature, from cabin SKODA_AAT_FROMCABIN

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature, from cabin sensor SKODA_AAT_CABIN

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

PTC heater current SKODA_PTC_HEATER_I

  • Service 22DID 1604
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.937 A
Unit
A

In testing for 2001 to 2026.

Radiator fan actual duty SKODA_RAD_FAN_ACT_DUTY

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator fan actual duty SKODA_RADIATOR_FAN_ACTUAL_DUTY

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator fan actual value #1 SKODA_HVAC_FAN1_ACT

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2001 to 2026.

Radiator fan actual value #2 SKODA_HVAC_FAN2_ACT

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2001 to 2026.

Radiator fan commanded duty SKODA_RADIATOR_FAN_COMMANDED_DUTY

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator fan commanded value SKODA_HVAC_FAN_CMD

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2001 to 2026.

Recirculation flap stop, fresh air SKODA_RECIRC_STOP_FRESH

  • Service 22DID 2620
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Recirculation flap stop, recirculated air SKODA_RECIRC_STOP_RECIRC

  • Service 22DID 2621
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Recirculation flap, actual SKODA_RECIRC_ACT_PCT

  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Recirculation flap, actual SKODA_RECIRC_FLAP_ACT_PCT

  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Recirculation flap, actual steps SKODA_RECIRC_ACT_STEPS

  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Recirculation flap, actual steps SKODA_RECIRC_FLAP_ACT_STEPS

  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Recirculation flap, commanded steps SKODA_RECIRC_CMD_STEPS

  • Service 22DID 261F
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Refrigerant pressure SKODA_REFRIG_P

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2
Range
0 to 51 bar
Unit
bar

In testing for 2001 to 2026.

Temperature, front left deflector SKODA_FL_DEFL_T

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Temperature, front right deflector SKODA_FR_DEFL_T

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Temperature, rear deflector SKODA_REAR_DEFL_T

  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Windshield temperature SKODA_WNDSHLD_TEMP

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

In testing for 2001 to 2026.

Heater

Heater current SKODA_PTC_HTR_I

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.74 A
Unit
A

In testing for 2001 to 2026.

Heater fluid temperature #1 SKODA_PTC_HTR_FLUID_T1

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Heater fluid temperature #2 SKODA_PTC_HTR_FLUID_T2

  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Clocks

Time since engine start SKODA_RUNTM

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2001 to 2026.

Control

Absolute pedal position, drive SKODA_APP_D

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position SKODA_APP_PE

  • Service 22DID F449
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position 1 SKODA_APP1

  • Service 22DID F449
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position 2 SKODA_APP2

  • Service 22DID F44A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal release detection threshold voltage SKODA_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2001 to 2026.

Accelerator pedal sensor 1 voltage SKODA_APP_V1

  • Service 22DID 102A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2001 to 2026.

Accelerator pedal sensor 2 voltage SKODA_APP_V2

  • Service 22DID 102B
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2001 to 2026.

Brake SKODA_BRAKE_PRESSED

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Brake booster low pressure, actual SKODA_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 2001 to 2026.

Brake booster pressure SKODA_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2001 to 2026.

Brake booster pressure SKODA_BRAKE_BOOSTER_P_V2

  • Service 22DID 2005
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Brake booster pressure SKODA_BRAKE_BST_P

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Brake booster pressure SKODA_PQ35_BRAKE_BOOSTER_P

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08291753
Range
0 to 5434
Unit
Raw value

In testing for 2001 to 2026.

Brake booster raw pressure SKODA_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Brake booster, actual vacuum SKODA_BRAKE_BOOSTER_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×390.6210000
Range
-1279 to 1279
Unit
Raw value

In testing for 2001 to 2026.

Brake pedal position SKODA_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Brake pressure SKODA_BRAKE_P

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2001 to 2026.

Brake pressure SKODA_BRAKE_P_7E0

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Brake pressure SKODA_BRAKE_P_7E0_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Brake pressure SKODA_BRAKE_P_V2

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2001 to 2026.

Brake pressure SKODA_BRAKE_PRES

  • Service 22DID 105C
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Brake pressure SKODA_MQB_TCM_BRAKE_P

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Brake pressure SKODA_PQ35_BRAKE_P

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Brake pressure reading valid? SKODA_BRAKE_PRESSED_VALID

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2001 to 2026.

Brake system vacuum pump active SKODA_BRAKE_SYSTEM_VACUUM

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Brake vacuum pump SKODA_ENG_BRAKE_PUMP

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Directional stability control active SKODA_CSS_ACT

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Directional stability control last activation distance SKODA_CSS_ODO_LAST

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

In testing for 2001 to 2026.

Directional stability control steering torque SKODA_CSS_STR_TRQ

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

In testing for 2001 to 2026.

Downshift point adaptation voltage SKODA_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2001 to 2026.

Electronic differential lock: front left brake temperature SKODA_EDL_FR_L_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val×0.5
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock: front right brake temperature SKODA_EDL_FR_R_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×0.5
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock: rear left brake temperature SKODA_EDL_RR_L_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val×0.5
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock: rear right brake temperature SKODA_EDL_RR_R_BRAKE_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val×0.5
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Hill descent control active SKODA_HDC_ACT

  • Service 22DID 1808
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Hill descent control incline angle SKODA_HDC_INC

  • Service 22DID 1808
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

Parking brake, air gap - left SKODA_PARKING_BRAKE_AIR

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2001 to 2026.

Parking brake, air gap - right SKODA_PARKING_BRAKE_AIR_GAP

  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 mm
Unit
mm

In testing for 2001 to 2026.

Pressure in brake servo unit SKODA_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2001 to 2026.

Requested brake torque, auxiliary system SKODA_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2001 to 2026.

Steering wheel angle SKODA_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 2B29
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 rad
Unit
rad

In testing for 2001 to 2026.

Steering wheel angle SKODA_STEER_ANGLE_V2

  • Service 22DID 0346
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °
Unit
°

In testing for 2001 to 2026.

Pedals

Accelerator pedal position sensor 1 SKODA_APP_POS1

  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2001 to 2026.

Accelerator pedal position sensor 2 SKODA_APP_POS2

  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2001 to 2026.

Drivetrain

Actual mechanical torque calculated SKODA_ACTUAL_MECHANICAL_TORQUE_CALC

  • Service 22DID 3EE9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Actual mechanical torque commanded SKODA_ACTUAL_MECHANICAL_TORQUE_CMD_VALUE

  • Service 22DID 58E1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Actual possible maximum torque SKODA_ACTUAL_POSSIBLE_MAXIMUM_TORQUE

  • Service 22DID 3EEA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Actual possible minimum torque SKODA_ACTUAL_POSSIBLE_MINIMUM_TORQUE

  • Service 22DID 3EEB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

All-wheel drive current SKODA_PQ35_HAL_I

  • Service 22DID 2BE6
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 A
Unit
A

In testing for 2001 to 2026.

All-wheel drive differential lock engagement SKODA_PQ35_HAL_DIFF_LK

  • Service 22DID 08A7
  • Module70F → 779
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2001 to 2026.

All-wheel drive duty cycle SKODA_PQ35_HAL_DUTY

  • Service 22DID 2BF3
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100.39255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

All-wheel drive mode SKODA_PQ35_HAL_MODE

  • Service 22DID 0C0A
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

All-wheel drive pulse width modulation SKODA_PQ35_HAL_PWM

  • Service 22DID 2BE7
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driver torque requested #1 SKODA_ENG_TRQ_REQ_1

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Driver torque requested #2 SKODA_ENG_TRQ_REQ_2

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Electric drive ECU temperature 1 SKODA_ELDRIVE_ECU_T_1

  • Service 22DID 0805
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Electric drive ECU temperature 2 SKODA_ELDRIVE_ECU_T_2

  • Service 22DID 0806
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Inverter power loss phase u SKODA_INVERTER_PWR_LOSS_PHASE_U

  • Service 22DID 1040
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2001 to 2026.

Inverter power loss phase v SKODA_INVERTER_PWR_LOSS_PHASE_V

  • Service 22DID 1041
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2001 to 2026.

Inverter power loss phase w SKODA_INVERTER_PWR_LOSS_PHASE_W

  • Service 22DID 1042
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2001 to 2026.

Motor electrical angular frequency SKODA_ELDRIVE_MOTOR_FREQ

  • Service 22DID 4657
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000
Unit
Number

In testing for 2001 to 2026.

Motor maximum current SKODA_MOTOR_MAXIMUM_I

  • Service 22DID 3EE7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 A
Unit
A

In testing for 2001 to 2026.

Motor minimum current SKODA_MOTOR_MINIMUM_I

  • Service 22DID 3EE8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 A
Unit
A

In testing for 2001 to 2026.

Motor speed SKODA_MOTOR_RPM_V2

  • Service 22DID 3DF8
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Motor torque difference, front to rear SKODA_MOTOR_TRQ_DIFF

  • Service 22DID 0343
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor torque rated, front SKODA_MOTOR_TRQ_RATED_FRONT

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor torque rated, rear SKODA_MOTOR_TRQ_RATED_REAR

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor torque requested SKODA_MOTOR_TRQ_REQ

  • Service 22DID 29D4
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor torque, front SKODA_MOTOR_TRQ_FRONT

  • Service 22DID 0335
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor torque, rear SKODA_MOTOR_TRQ_REAR

  • Service 22DID 033B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Motor voltage, d-axis actual SKODA_MOTOR_V_D_ACT

  • Service 22DID 1007
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

Motor voltage, d-axis commanded SKODA_MOTOR_V_D_CMD

  • Service 22DID 1009
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

Motor voltage, q-axis actual SKODA_MOTOR_V_Q_ACT

  • Service 22DID 1008
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

Motor voltage, q-axis commanded SKODA_MOTOR_V_Q_CMD

  • Service 22DID 100A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2001 to 2026.

Torque, calculated from measured currents SKODA_CALC_FROM_MEAS_IS

  • Service 22DID 0308
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared SKODA_CLR_DIST

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Distance traveled while mil was activated SKODA_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Number of warm-ups since diagnostic trouble codes cleared SKODA_WARM_UPS

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

ECU

Misfires, cylinder 2 SKODA_MISFIRES__CYL__2

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 4 SKODA_MISFIRES__CYL__4

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Torque converter slip SKODA_TORQUE_CONVERTER_SLIP_TCM

  • Service 22DID 2131
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Emissions

Particulate filter differential pressure, raw count SKODA_DPF_DIFF_P_RAW

  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2001 to 2026.

Time since particulate filter regeneration, raw count SKODA_TIME_SINCE_REGEN_RAW

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine

A/C clutch SKODA_CLIMATE_A_C_CLCH

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

A/C compressor load SKODA_CLIMATE_A_C_COMP_LOAD

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

In testing for 2001 to 2026.

A/C compressor torque SKODA_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

A/C compressor torque SKODA_A_C_COMPRESSOR_TORQUE_V2

  • Service 22DID 101A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

A/C refrigerant pressure SKODA_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2001 to 2026.

A/C refrigerant pressure SKODA_A_C_REFRIGERANT_PRES_V2

  • Service 22DID 1017
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2001 to 2026.

Actual turbo boost SKODA_ACT_TURBO_BOOST

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2 bar
Unit
bar

In testing for 2001 to 2026.

Adaptation of loss torque SKODA_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Adaptation of throttle valve SKODA_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder1 fast diagnosis SKODA_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder1 slow diagnosis SKODA_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder2 fast diagnosis SKODA_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder2 slow diagnosis SKODA_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder3 fast diagnosis SKODA_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder3 slow diagnosis SKODA_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder4 fast diagnosis SKODA_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptation val.cylinder4 slow diagnosis SKODA_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2001 to 2026.

Adaptive mode SKODA_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Air conditioning compressor pressure SKODA_AC_COMP_P

  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2001 to 2026.

Air conditioning compressor pressure SKODA_AC_COMP_P_V2

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2001 to 2026.

Air conditioning compressor pressure, linear raw value SKODA_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2001 to 2026.

Air conditioning compressor refrigerant pressure SKODA_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2001 to 2026.

Air conditioning compressor torque SKODA_AC_COMP_TQ

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Air conditioning compressor torque SKODA_AC_COMP_TQ_7E0

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2001 to 2026.

Air conditioning compressor torque SKODA_AC_COMP_TQ_V2

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Air conditioning compressor torque request SKODA_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Air conditioning refrigerant pressure SKODA_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2001 to 2026.

Air filling SKODA_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Air intake vacuum SKODA_AIR_VAC

  • Service 22DID 1816
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Air leakage SKODA_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Air mass SKODA_AIR_MASS

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2001 to 2026.

Air mass meter 1 SKODA_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Air mass, actual value, mg/stroke SKODA_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Air mass, specified value SKODA_AIR_MASS_SPEC

  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2001 to 2026.

Air pollution level SKODA_CLIMATE_AIR_POLUTION_LVL

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7
Unit
Number

In testing for 2001 to 2026.

All-wheel drive temperature SKODA_PQ35_HAL_T

  • Service 22DID 2BF1
  • Module70F → 779
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val100−227.67
Range
-40 to 200 °C
Unit
°C

In testing for 2001 to 2026.

All-wheel-drive pump current SKODA_AWD_PMP_CURRENT

  • Service 22DID 2B0D
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×956325500−47.63
Range
-47.63 to 47.9999 A
Unit
A

In testing for 2001 to 2026.

Alternator load SKODA_ALTERNATOR_LOAD

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Alternator load SKODA_ALTERNATOR_LOAD_V2

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

In testing for 2001 to 2026.

Ambient air pressure SKODA_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 2001 to 2026.

Ambient air temperature SKODA_DASH_AMBIENT_AIR_T

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.5−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Ambient air temperature, v1 SKODA_AAT_V1

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2001 to 2026.

Ambient temperature SKODA_AAT_7E0

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Ambient temperature SKODA_AAT_7E0_2

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2001 to 2026.

Analysis-39 driving recorder total time SKODA_ANALYSIS_39_DRIVING

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 1, maximum temperature SKODA_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Analysis, clutch 2, maximum temperature SKODA_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Automatic engine starts counter SKODA_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Automatic transmission fluid temperature, lifetime max SKODA_ATF_MAX

  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Automatic transmission fluid temperature, variant 2 SKODA_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONIC

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Aux. hydraulic pump internal temperature SKODA_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Aux. hydraulic pump, current SKODA_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2001 to 2026.

Average ignition timing angle delay adjustment SKODA_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Avg. injection time SKODA_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

In testing for 2001 to 2026.

Avg. injection time SKODA_AVG_INJ_TIME_7E0

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2001 to 2026.

Barometric pressure SKODA_BAROMETRIC_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 kPa
Unit
kPa

In testing for 2001 to 2026.

Basic correction factor:, cylinder 1, filtered SKODA_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2001 to 2026.

Basic correction factor:, cylinder 2, filtered SKODA_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2001 to 2026.

Basic correction factor:, cylinder 3, filtered SKODA_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2001 to 2026.

Basic correction factor:, cylinder 4, filtered SKODA_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2001 to 2026.

Battery management controller e temperature 4 SKODA_E_TRON_BMS_BMCE_T_CAN

  • Service 22DID 1810
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2001 to 2026.

BMC-E temperature, 1 SKODA_BMS_BMCE_T1

  • Service 22DID 180C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

BMC-E temperature, 2 SKODA_BMS_BMCE_T2

  • Service 22DID 180D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

BMC-E temperature, 3 SKODA_BMS_BMCE_T3

  • Service 22DID 180E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

BMC-E temperature, 4 SKODA_BMS_BMCE_T_CAN

  • Service 22DID 1810
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Boost press before throttle: calculated actual value SKODA_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2001 to 2026.

Boost pressure actuator, commanded duty SKODA_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 2001 to 2026.

Boost pressure commanded SKODA_BOOST_P_CMD

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Boost pressure, actual SKODA_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Boost pressure, actual SKODA_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 2001 to 2026.

Boost pressure, target SKODA_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2001 to 2026.

Boost regulation duty, commanded value SKODA_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Boost regulator feedback SKODA_BOOST_REGULATOR

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Boost regulator feedback SKODA_BOOST_REGULATOR_FEEDBACK

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Break pressure SKODA_BREAK_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543 to 458 bar
Unit
bar

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, activation SKODA_BYPASS_VLV_HIGH_P_TURBINE_INLET_V2

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, activation SKODA_BYPASS_VLV_HIGH_P_V2

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, actual value SKODA_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, offset closed SKODA_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, offset closed SKODA_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 399 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, offset open SKODA_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 399 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, offset open SKODA_BYPASS_VLV_HIGH_P_TURBINE_V2

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2001 to 2026.

Bypass valve high pressure turbine inlet, target value SKODA_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2001 to 2026.

Bze_q_elad SKODA_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2001 to 2026.

Bze_q_lad SKODA_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2001 to 2026.

Cabin temperature SKODA_C7_CABIN_T

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127.99 °C
Unit
°C

In testing for 2001 to 2026.

Cabin temperature SKODA_CABIN_T

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Calculated oil temperature SKODA_PQ35_CALCULATED_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Camshaft adaptation exhaust bank 1, phase position SKODA_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1_PHASE_7E0

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation intake, phase position SKODA_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation, counter due to knock SKODA_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Camshaft adaptation, exhaust bank 1, phase position SKODA_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation, intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Camshaft adaptation, intake deviation SKODA_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment intake bank 1, activation % SKODA_CAM_ADJ_INT_BANK_1

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Camshaft adjustment intake test bank 1 SKODA_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Camshaft adjustment outlet test bank 1 SKODA_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Camshaft adjustment, exhaust bank 1, actual value SKODA_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, exhaust bank 1, specified value SKODA_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, exhaust bank 2, actual value SKODA_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, exhaust bank 2, specified value SKODA_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, exhaust, activation SKODA_CAM_ADJ_EXH

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Camshaft adjustment, exhaust, actual value SKODA_CAM_ADJ_EXH_ACT

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, exhaust, specified value SKODA_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, intake bank 1, actual value SKODA_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, intake bank 1, specified value SKODA_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, intake, actual value SKODA_CAM_ADJ_INT_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft adjustment, intake, specified value SKODA_CAM_ADJ_INT_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Camshaft end position SKODA_CAMS_END

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2001 to 2026.

Camshaft position, deviation from the base position SKODA_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2001 to 2026.

Camshaft position, start of phase window SKODA_CAM_POS_START_PHASE

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2001 to 2026.

Camshaft start position SKODA_PQ35_CAMS_START

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2001 to 2026.

Cat. converter oxygen storage capacity measured SKODA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Cat. converter oxygen storage capacity measured SKODA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_V2

  • Service 22DID 1507
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Cat. temperature, bank 1 SKODA_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2001 to 2026.

Cat. temperature, bank 2 SKODA_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2001 to 2026.

Catalyst temperature, calculated SKODA_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2001 to 2026.

Centrifugal oil temperature SKODA_PQ35_CENTRIFUGAL_OIL_T

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2001 to 2026.

Chain elongation inlet, mileage at last adaptation SKODA_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Chain elongation outlet, mileage at last adaptation SKODA_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 SKODA_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Chain elongation, no of valid initial values, intake bank 1 SKODA_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Charge air cooler downstream air pressure SKODA_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Clutch #1 maximum temperature SKODA_PQ35_CLUTCH_1_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2001 to 2026.

Clutch #2 maximum temperature SKODA_PQ35_CLUTCH_2_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 0 temperature calculated SKODA_C7_CLUTCH_0_T_CALCULATED

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 600 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 0 temperature calculated SKODA_MQB_DL382_CLUTCH_0_T_CALCULATED

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 600 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 1 temperature SKODA_CLUTCH_1_T

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 1 temperature SKODA_PQ35_CLUTCH_1_T

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 1 temperature protection warning 1 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 1 temperature protection warning 2 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 2 temperature SKODA_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 2 temperature SKODA_PQ35_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 2 temperature protection warning 1 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 2 temperature protection warning 2 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch center central plate temperature SKODA_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Clutch temperature SKODA_DIFF_CLUTCH_T

  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2−50
Range
-50 to 460 °C
Unit
°C

In testing for 2001 to 2026.

Commanded crankshaft torque SKODA_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Compression test cylinder 1 SKODA_COMPRESSION_TEST_CYL_1

  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test cylinder 2 SKODA_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test cylinder 3 SKODA_PQ35_COMP_TEST_CYL_3

  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test cylinder 4 SKODA_PQ35_COMP_TEST_CYL_4

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test, cylinder 1 SKODA_COMPRESSION_TEST_CYL_1_7E0

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test, cylinder 2 SKODA_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test, cylinder 3 SKODA_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Compression test, cylinder 4 SKODA_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Control module temperature SKODA_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Control module temperature SKODA_CTRL_MODULE_T_V2

  • Service 22DID 028D
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Control module temperature SKODA_E_TRON_TRON_ENG_CTRL_MODULE_T

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Control module temperature SKODA_ECU_TEMP

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Control module temperature SKODA_ECU_TEMP_KELVIN

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-40 to 150 °C
Unit
°C

In testing for 2001 to 2026.

Control module temperature SKODA_MQB_TCM_ECU_T

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Converter loss torque SKODA_TCM_CONVERTER_LOSS_TORQUE

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Coolant circulation pump duty SKODA_COOLANT_CIRC_PUMP_DUTY

  • Service 22DID 276D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant circulation pump, activation SKODA_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant circulation pump, control SKODA_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 1 activation, $1117 SKODA_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 1 duty cycle SKODA_COOL_FAN_1_DUTY

  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 1, activation SKODA_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 1, activation SKODA_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 1, activation SKODA_COOLANT_FAN_1_ACTIVATION_V2

  • Service 22DID 1130
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 2 duty SKODA_CLT_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 2 duty cycle SKODA_PQ35_COOL_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan 2, activation SKODA_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant fan activation, actual value SKODA_CLT_FAN_ACTIVATION_ACT

  • Service 22DID 2606
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2001 to 2026.

Coolant fan activation, specified value SKODA_CLT_FAN_ACTIVATION_SPEC

  • Service 22DID 2607
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2001 to 2026.

Coolant fan, requested by A/C SKODA_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2001 to 2026.

Coolant shut-off valve, closed SKODA_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2001 to 2026.

Coolant temperature at engine outlet, calculated SKODA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at engine outlet, calculated SKODA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_V2

  • Service 22DID 4490
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at engine outlet, calculated SKODA_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at engine start SKODA_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at engine start SKODA_COOLANT_T_AT_ENGINE_START_V2

  • Service 22DID 1291
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at engine start SKODA_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet SKODA_COOLANT_T

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet SKODA_EARLY_COOLANT_T

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet SKODA_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet 2 SKODA_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet v.1 SKODA_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet, actual value SKODA_ECT_RADIATOR_OUTLET_ACT

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet, actual value SKODA_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator outlet, specified value SKODA_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature at radiator output, specified value SKODA_COOLANT_T_AT_RADIATOR_OUTPUT_SPECIFIED_VALUE

  • Service 22DID 1135
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature difference between engine and radiator SKODA_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature linear SKODA_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2929710000000−48
Range
-48 to 143.9978 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature modeled value SKODA_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature modeled value SKODA_COOLANT_T_MODELED_VALUE_V2

  • Service 22DID 13A0
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature, maximum value SKODA_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Coolant temperature, minimum value SKODA_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Cooling fan 2 SKODA_COOLING_FAN_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2001 to 2026.

Cooling inlet temperature SKODA_BMS_COOL_IN_T

  • Service 22DID 181C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Cooling outlet temperature SKODA_BMS_COOL_OUT_T

  • Service 22DID 181D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Correction factor of oil temperature for engine protection SKODA_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 2001 to 2026.

Correction values for main pressure adaptation SKODA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Counter steer support, steering torque SKODA_CNT_STEER_SUPPORT_STEERING_TRQ

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 N·m
Unit
N·m

In testing for 2001 to 2026.

Coupling solenoid current SKODA_CPL_SOL_I

  • Service 22DID 1800
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122076250000
Range
-63.99 to 63.99 A
Unit
A

In testing for 2001 to 2026.

Crankshaft rotation angle when closing the quantity control valve SKODA_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Critical engine oil level SKODA_PQ35_OIL_LVL_CRIT

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2001 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 SKODA_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 SKODA_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 SKODA_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Current N215 pressure control valve 1 SKODA_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current N216 pressure control valve 2 SKODA_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current N217 pressure control valve 3 SKODA_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current N218 pressure control valve 4 SKODA_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current N233 pressure control valve 5 SKODA_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current N443 pressure control valve 7 main pressure SKODA_CURRENT_N443_P_CTRL_7_P

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current solenoid SKODA_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current type of driver counter SKODA_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Cylinder 1 internal torque SKODA_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Cylinder 2 internal torque SKODA_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Cylinder 3 internal torque SKODA_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Cylinder 4 internal torque SKODA_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Cylinder block temperature sensor SKODA_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Cylinder head temperature SKODA_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2001 to 2026.

Cylinder head temperature, actual SKODA_CYL_HEAD_T_ACT

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Desired torque filtered SKODA_DES_TQ_FILTERED

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Desired torque raw SKODA_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Diesel particulate filter air pressure sensor raw value SKODA_DPF_AIR_P_SENS_RAW

  • Service 22DID 4494
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter ash load limit SKODA_DPF_ASH_LOAD_LIM

  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter cleaning deviation reaction time SKODA_DPF_CLEANING_DEV

  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter counter for regeneration time SKODA_DPF_CNT_REGEN_TIME

  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter differential pressure SKODA_DPF_DIFF_P

  • Service 22DID 2084
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure offset SKODA_PQ35_DPF_DIFF_P_OFFSET

  • Service 22DID 10F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure raw value, bank 1 SKODA_DPF_DIFF_P_RAW_BANK_1

  • Service 22DID 166B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure raw value, bank 2 SKODA_DPF_DIFF_P_RAW_BANK_2

  • Service 22DID 166C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure sensor temperature SKODA_DPF_DIFF_P_SENS_T

  • Service 22DID 43C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195311000000−50
Range
-689.9918 to 589.9722 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter differential pressure variant 2 SKODA_PQ35_DPF_DIFF_P_2

  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure, raw value 1 SKODA_DPF_DIFF_P_RAW_1

  • Service 22DID 43BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter differential pressure, raw value 2 SKODA_DPF_DIFF_P_RAW_2

  • Service 22DID 43BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter exhaust gas flow volume SKODA_DPF_EXH_VOL

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter exhaust temperature SKODA_DPF_EXH_T

  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter field regeneration, cancel conditions SKODA_DPF_FIELD_REGEN

  • Service 22DID 29F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter field regeneration, lock status SKODA_DPF_FIELD_REGEN_LOCK_V2

  • Service 22DID 2088
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter inlet temperature SKODA_PQ35_DPF_IN_T

  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter input gas temperature SKODA_DPF_INPUT_GAS_T

  • Service 22DID 297B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−20
Range
-20 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter input gas temperature SKODA_DPF_INPUT_GAS_T_7E0

  • Service 22DID 449B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter input temperature raw value SKODA_DPF_INPUT_T_RAW

  • Service 22DID 449B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter offset for differential pressure SKODA_DPF_OFFSET_DIFF_P

  • Service 22DID 2085
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter oil ash mass SKODA_DPF_OIL_ASH_MASS

  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter oil ash mass SKODA_MQB_DPF_OIL_ASH_MASS

  • Service 22DID 1ABD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.001192110000
Range
0 to 512
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter oil ash volume SKODA_DPF_OIL_ASH_VOLUME

  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter oil ash volume, bank 1 SKODA_DPF_OIL_ASH_VOLUME_1

  • Service 22DID 14B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter oil ash volume, bank 2 SKODA_DPF_OIL_ASH_VOLUME_2

  • Service 22DID 145F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter outlet temperature SKODA_EARLY_DPF_OUT_T

  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1200 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter outlet temperature SKODA_PQ35_DPF_OUT_T

  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter output gas temperature SKODA_DPF_OUTPUT_GAS_T

  • Service 22DID 297D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−20
Range
-20 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter output temperature raw value SKODA_DPF_OUTPUT_T_RAW

  • Service 22DID 449A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter regeneration cancel conditions SKODA_DPF_REGEN_CANCEL

  • Service 22DID 137C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration level current SKODA_DPF_REGEN_LEVEL

  • Service 22DID 080D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration request status SKODA_DPF_REGEN_REQ_STAT

  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration status SKODA_DPF_REGEN_STAT

  • Service 22DID 0809
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter soot mass calculated, bank 1 SKODA_DPF_SOOT_MASS_CALC_1

  • Service 22DID 14BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter soot mass calculated, bank 2 SKODA_DPF_SOOT_MASS_CALC_2

  • Service 22DID 145E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter soot mass measured, bank 1 SKODA_DPF_SOOT_MASS_MEAS_1

  • Service 22DID 14BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter soot mass measured, bank 2 SKODA_DPF_SOOT_MASS_MEAS_2

  • Service 22DID 145D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter soot measured SKODA_DPF_SOOT_MEAS

  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter soot volume in exhaust, mg/m^3 SKODA_DPF_SOOT_VOLUME_EXH_M_3

  • Service 22DID 18C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics current avg. temperature after DPF SKODA_DPF_STATISTICS_T

  • Service 22DID 157C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter statistics current avg. temperature after part.filter SKODA_DPF_STATISTICS_CURRENT_AVG_T

  • Service 22DID 4001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter statistics current calculated charging rate, g/km SKODA_DPF_STATISTICS_CURRENT_G

  • Service 22DID 4007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×12207100000000
Range
-3.99 to 3.99
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics current measured charging rate, g/km SKODA_DPF_STATISTICS_G

  • Service 22DID 4005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×12207100000000
Range
-3.99 to 3.99
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics, regeneration time SKODA_DPF_STATISTICS_REGEN

  • Service 22DID 401F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64
Range
0 to 16320 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter surface gas temperature SKODA_DPF_SURFACE_GAS_T

  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter surface temperature SKODA_DPF_SFC_T

  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter surface temperature SKODA_DPF_SURFACE_T

  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16−273.15
Range
-2321.15 to 1774.7875 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter surface temperature SKODA_PQ35_DPF_SURF_T

  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Diesel particulate filter time since last regeneration SKODA_DPF_TIME_SINCE_REGEN

  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val3600
Range
0 to 1193046 h
Unit
h

In testing for 2001 to 2026.

Diesel particulate filter time since last regeneration, h, bank 1 SKODA_DPF_TIME_SINCE_REGEN_H_1

  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val3600
Range
0 to 1193046
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter time since last regeneration, h, bank 2 SKODA_DPF_TIME_SINCE_REGEN_H_2

  • Service 22DID 1464
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val3600
Range
0 to 1193046
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter, differential pressure sensor, adapted value SKODA_DPF_DIFF_P_SENS_ADAPTED

  • Service 22DID 44B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter, differential pressure sensor, dynamic offset SKODA_DPF_DIFF_P_SENS

  • Service 22DID 44A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter, service regeneration while driving SKODA_DPF_SERVICE_REGEN_WHILE

  • Service 22DID 2910
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter, service regeneration, current duration SKODA_DPF_SERVICE_REGEN

  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2001 to 2026.

Differential pressure SKODA_DIFF_P

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Direct injections counter SKODA_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Drive motor current SKODA_MOTOR_I

  • Service 22DID 147D
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2001 to 2026.

Drive motor effective current SKODA_MOTOR_I_RMS

  • Service 22DID 4665
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase U current SKODA_MOTOR_U_I

  • Service 22DID 3EF9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase U current, unlimited SKODA_MOTOR_U_I_RAW

  • Service 22DID 4671
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase V current SKODA_MOTOR_V_I

  • Service 22DID 3EFA
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase V current, unlimited SKODA_MOTOR_V_I_RAW

  • Service 22DID 4670
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase W current SKODA_MOTOR_W_I

  • Service 22DID 3EFB
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase W current, unlimited SKODA_MOTOR_W_I_RAW

  • Service 22DID 466F
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2001 to 2026.

Drive motor power SKODA_MOTOR_PWR

  • Service 22DID 147E
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2001 to 2026.

Drive motor power, actual SKODA_MOTOR_PWR_PE

  • Service 22DID 4656
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 kW
Unit
kW

In testing for 2001 to 2026.

Drive motor power, calculated SKODA_MOTOR_PWR_CALC

  • Service 22DID 4658
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 kW
Unit
kW

In testing for 2001 to 2026.

Drive motor speed SKODA_MOTOR_RPM_ECM

  • Service 22DID 149A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor speed 2 SKODA_MOTOR_RPM_2

  • Service 22DID 3EEC
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor speed, actual SKODA_MOTOR_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID 3E97
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor speed, measured SKODA_MOTOR_RPM_ACT

  • Service 22DID 4659
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor speed, standard SKODA_MOTOR_RPM_SAE

  • Service 22DID F40C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor stator temperature SKODA_MOTOR_STATOR_T

  • Service 22DID 4672
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

Drive motor temperature SKODA_MOTOR_T

  • Service 22DID 3E94
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

Drive motor torque SKODA_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2001 to 2026.

Drive motor torque, actual SKODA_MOTOR_TQ_PE

  • Service 22DID 3EE9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2001 to 2026.

Drive motor torque, calculated SKODA_MOTOR_TQ_CALC

  • Service 22DID 0308
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2001 to 2026.

Drive motor voltage SKODA_MOTOR_V

  • Service 22DID 1484
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

Driver demand torque SKODA_MQB_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Driver demand torque SKODA_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Driving mode sensor, hall sensor a SKODA_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Driving position SKODA_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Driving resistance index SKODA_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2001 to 2026.

Dynamic average of ignition angle delay adjustment SKODA_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Dynamic torque limitation SKODA_DYNAMIC_TQ_LIM

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Ea888b boost pressure control, adaptation value 0 SKODA_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359 to 356
Unit
Raw value

In testing for 2001 to 2026.

Ea888b boost pressure control, adaptation value 1 SKODA_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359 to 356
Unit
Raw value

In testing for 2001 to 2026.

Ea888b boost pressure control, adaptation value 2 SKODA_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2001 to 2026.

Ea888b boost pressure control, adaptation value 3 SKODA_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2001 to 2026.

Ea888b boost pressure regulator, commanded SKODA_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Early ignition counter for toque reduction, cylinder 1 SKODA_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for toque reduction, cylinder 2 SKODA_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for toque reduction, cylinder 3 SKODA_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for toque reduction, cylinder 4 SKODA_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, total, cylinder 1 SKODA_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, total, cylinder 2 SKODA_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, total, cylinder 3 SKODA_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter, total, cylinder 4 SKODA_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Effective injection duration SKODA_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2001 to 2026.

EGT after catalyst, model bank 1 SKODA_EGT_AFTER_CAT_MODEL_1

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2001 to 2026.

EGT after catalyst, model bank b SKODA_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2001 to 2026.

Elector motor 1 torque SKODA_EM_TORQ_1

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Elector motor 2 torque SKODA_EM_TORQ_2

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Elector motor 3 torque SKODA_EM_TORQ_3

  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2001 to 2026.

Electric additional coolant pump control, high circle SKODA_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2001 to 2026.

Electric motor 1 rpm SKODA_EM_RPM_1

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-100 to 100 rpm
Unit
rpm

In testing for 2001 to 2026.

Electric motor 2 rpm SKODA_EM_RPM_2

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-100 to 100 rpm
Unit
rpm

In testing for 2001 to 2026.

Electric motor non-vehicle power limitation SKODA_EM_NV_PWR_LIM

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

In testing for 2001 to 2026.

Electric motor power limitation SKODA_EM_PWR_LIM

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

In testing for 2001 to 2026.

Electric motor RPM SKODA_ENG_MOTOR_RPM

  • Service 22DID 3DF8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Electronic differential lock active SKODA_ELEC_DIFF_ACT

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Electronic differential lock front left brake temperature SKODA_ELEC_DIFF_FL_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock front right brake temperature SKODA_ELEC_DIFF_FR_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock rear left brake temperature SKODA_ELEC_DIFF_RL_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Electronic differential lock rear right brake temperature SKODA_ELEC_DIFF_RR_BRK_T

  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Energy balance of last driving cycle SKODA_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 2001 to 2026.

Energy content SKODA_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Engine air mass, specified value SKODA_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Engine compartment temperature raw value SKODA_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Engine control module temperature SKODA_ENG_CTRL_MODULE_T

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Engine drag torque SKODA_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine module 10E0, raw SKODA_ECM_10E0_RAW

  • Service 22DID 10E0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine module 11BD, raw SKODA_ECM_11BD_RAW

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Engine module 11BE, raw SKODA_ECM_11BE_RAW

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Engine module 2005, raw SKODA_ECM_2005_RAW

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Engine oil level SKODA_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2001 to 2026.

Engine oil level SKODA_ENG_OIL_LEVEL_7E0_2

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131 to 131 mm
Unit
mm

In testing for 2001 to 2026.

Engine oil level SKODA_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2001 to 2026.

Engine oil level current value SKODA_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine oil pressure SKODA_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 2001 to 2026.

Engine oil sump temperature SKODA_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_714

  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−58
Range
0 to 197
Unit
Number

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_7E0_7E0

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_7E0_V2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_FC00

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 11BD
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_V2

Scaling is unknown, needs further validation.

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine oil temperature SKODA_EOT_V3

  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−58
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Engine oil temperature 2 SKODA_PQ35_ENGINE_OIL_T_2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature measured value SKODA_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature sensor 2 SKODA_EOT_SENS_2

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature, calculated SKODA_EOT_CALC

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature, engine control module SKODA_EOT_ECM

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-40 to 200 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature, pulse sensor SKODA_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Engine outlet coolant temperature calculated SKODA_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Engine protection, torque limit SKODA_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine radiator fan request SKODA_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine read 10E0, signed raw count SKODA_10E0_RAW

  • Service 22DID 10E0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2001 to 2026.

Engine read 11BE, signed raw count SKODA_11BE_RAW

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2001 to 2026.

Engine read 162D, raw count SKODA_162D_RAW

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Engine read 1153, raw count SKODA_1153_RAW

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Engine read 1164, raw count SKODA_1164_RAW

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine start quantity SKODA_PQ35_ENG_START_QTY

  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Engine temperature control actuator SKODA_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine temperature management actuator, after-run stop SKODA_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine temperature management actuator, duty cycle activation SKODA_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine temperature management actuator, raw value SKODA_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine temperature management actuator, specified value SKODA_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine temperature management actuator, stop open SKODA_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TORQUE

  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E0

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E0_7E0

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E0_7E0_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E1

  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E1_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_7E1_V2

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENG_TQ_V2

  • Service 22DID 2002
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×49625
Range
0 to 5137
Unit
Number

In testing for 2001 to 2026.

Engine torque SKODA_ENGINE_TORQUE

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_ENGINE_TORQUE_V2

  • Service 22DID 1010
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_PQ35_ENG_TORQUE

  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_PQ35_ENG_TRQ

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque SKODA_TCM_ENGINE_TORQUE

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque limitation SKODA_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque limitation SKODA_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine torque loss SKODA_TCM_ENGINE_TORQUE_LOSS

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Environment data camshaft input 1 SKODA_ENVD_CAM_IN_1

  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Evaporator temperature SKODA_EVAPORATOR_T

  • Service 22DID 42BB
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Excessive temperature protection SKODA_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Exhaust camshaft, adaptation bias SKODA_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2001 to 2026.

Exhaust camshaft, adaptation sensor tolerance SKODA_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2001 to 2026.

Exhaust gas jet volume in particle filter SKODA_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 2001 to 2026.

Exhaust gas jet volume in particle filter, m^3/h SKODA_EXH_GAS_JET_VOLUME_M_3_H

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364
Unit
Number

In testing for 2001 to 2026.

Exhaust gas recirculation valve 2 bank 1 mass flow SKODA_MQB_EGR_VALVE_2_B1_FLOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Exhaust gas recirculation valve duty SKODA_PQ35_EGR_DUTY

  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Exhaust gas temperature SKODA_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature - calculated after catalyst SKODA_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature at probe before the front catalytic converter, model value SKODA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature at the probe before the front catalytic converter, model value SKODA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE_V2

  • Service 22DID 139C
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature before catalyst SKODA_EXHAUST_GAS_T_BEFORE_CATALYST

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature before catalyst, modeled SKODA_EGT_PRE_CAT_MODELED

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature before catalytic converter SKODA_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature before gasoline particulate filter SKODA_EXH_GAS_T_BEFORE_GPF

  • Service 22DID 082D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 1 SKODA_EXH_GAS_T_SENS_1

  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 1 SKODA_EXH_GAS_T_SENS_1_7E0

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 1 SKODA_PQ35_EXH_GAS_T_1

  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 1, bank 2 SKODA_EXH_GAS_T_SENS_1_2

  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 2 SKODA_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 3 SKODA_EXH_GAS_T_SENS_3

  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 3 SKODA_EXH_GAS_T_SENS_3_7E0

  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 3 SKODA_EXH_GAS_T_SENS_3_V2

  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 3, bank 2 SKODA_EXH_GAS_T_SENS_3_2

  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 4 SKODA_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature sensor 4 SKODA_EXH_GAS_T_SENS_4_7E0

  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust gas temperature, sensor 4 bank 2 SKODA_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust phase deviation, actual value SKODA_EXH_PHASE_DEV_ACT

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2001 to 2026.

Exhaust phase deviation, after chain replacement SKODA_EXH_PHASE_DEV_AFTER

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2001 to 2026.

Exhaust phase deviation, after repair SKODA_EXH_PHASE_DEV_AFTER_REPAIR

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2001 to 2026.

Exhaust temperature before the catalyst, modeled SKODA_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error SKODA_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Exhaust timing chain extension, mileage since last adaptation SKODA_EXH_TIM_CHAIN

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Field limit SKODA_FIELD_LIM

  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2001 to 2026.

Field limit value SKODA_PQ35_FIELD_LIM

  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Field regeneration request status SKODA_FIELD_REGEN_REQ_STAT

  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

First pilot injection, duration SKODA_PRE_INJ_1_DUR

  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

First pilot injection, start SKODA_PRE_INJ_1_START

  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Friction torque SKODA_FRICTION_TQ

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Front defrost flap air outlet temperature SKODA_FRONT_DEFROST_FLAP_T

  • Service 22DID 42C8
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Front left deflector temperature SKODA_CLIMATE_FR_L_DEFL_T

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Front left temperature flap actual value SKODA_CLIMATE_FR_L_T_FLP_ACT_VALUE

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Front right deflector temperature SKODA_CLIMATE_FR_R_DEFL_T

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Front right temperature flap actual value SKODA_CLIMATE_FR_R_T_FLP_ACT_VALUE

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel metering valve position SKODA_FUEL_METER

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel temperature SKODA_FUEL_T_7E0

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-40 to 300 °C
Unit
°C

In testing for 2001 to 2026.

Fuel temperature SKODA_PQ35_FUEL_T

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Gasoline particulate filter blockage rate calculated SKODA_GPF_BLOCKAGE_RATE_CALC

  • Service 22DID 2AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1280
Range
0 to 51.1992
Unit
Number

In testing for 2001 to 2026.

Gasoline particulate filter blockage rate threshold calculated SKODA_GPF_BLOCKAGE_RATE

  • Service 22DID 2AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1280
Range
0 to 51.1992
Unit
Number

In testing for 2001 to 2026.

Gasoline particulate filter blockage ratio calculated absolute SKODA_GPF_BLOCKAGE_RAT

  • Service 22DID 0827
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Gasoline particulate filter blockage ratio calculated relative SKODA_GPF_BLOCKAGE_RAT_CALC_REL

  • Service 22DID 0828
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Gasoline particulate filter high level moisture build-up SKODA_GPF_HIGH_LEVEL

  • Service 22DID 24B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2001 to 2026.

Gasoline particulate filter high level of soot build-up SKODA_GPF_HIGH_LEVEL_SOOT

  • Service 22DID 24B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Gasoline particulate filter loading stage SKODA_GPF_LOADING_STAGE

  • Service 22DID 082B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Gasoline particulate filter maximum ash build-up reached SKODA_GPF_MAX_ASH_BUILD_UP

  • Service 22DID 24B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510
Unit
Raw value

In testing for 2001 to 2026.

Gasoline particulate filter maximum soot build-up reached SKODA_GPF_MAX_SOOT_BUILD

  • Service 22DID 24B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Gasoline particulate filter oil ash load calculated SKODA_GPF_OIL_ASH_LOAD

  • Service 22DID 0804
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Gasoline particulate filter soot load calculated SKODA_GPF_SOOT_LOAD_CALC

  • Service 22DID 0829
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Gasoline particulate filter soot mass calculated SKODA_GPF_SOOT_MASS_CALC

  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Gasoline particulate filter water load SKODA_GPF_WATER_LOAD

  • Service 22DID 0802
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Gasoline particulate filter water mass SKODA_GPF_WATER_MASS

  • Service 22DID 2139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2001 to 2026.

Generator current SKODA_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2001 to 2026.

Generator load SKODA_GEN_LOAD

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator load normalized value SKODA_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator load normalized value SKODA_GENERATOR_LOAD_NORMALIZED_VALUE_V2

  • Service 22DID 15CA
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator load signal SKODA_GEN_LOAD_SIG

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Generator load signal SKODA_GEN_LOAD_SIG_7E0

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator load signal SKODA_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator load signal SKODA_GENERATOR_LOAD_SIG_V2

  • Service 22DID 101C
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Generator performance SKODA_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2001 to 2026.

Generator performance SKODA_GENERATOR_PERFORMANCE_V2

  • Service 22DID 1097
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.4216 W
Unit
W

In testing for 2001 to 2026.

Generator power SKODA_GEN_POWER

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9.4247
Range
0 to 617647.7145 W
Unit
W

In testing for 2001 to 2026.

Generator torque request SKODA_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Generator torque request SKODA_GENERATOR_TORQUE_REQUEST_V2

  • Service 22DID 101B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Heater circulation pump, nominal value SKODA_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Heater support pump, specified value SKODA_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Height correction SKODA_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2001 to 2026.

High pressure control, adaptation SKODA_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2001 to 2026.

High pressure EGR actuator, activation SKODA_HIGH_P_EGR_ACTUATOR

  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

High pressure regulation, adaptation value SKODA_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

High-pressure exhaust gas recirculation closing, variant 1 SKODA_HIGH_P_EGR_CLOSING_1

  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×-2564+100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

High-pressure exhaust gas recirculation closing, variant 2 SKODA_HIGH_P_EGR_CLOSING_2

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×-2564+100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Humidity sensor, relative humidity SKODA_HUMIDITY_SENS_REL

  • Service 22DID 5036
  • Module70E → 778
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×99200
Range
0 to 32439 %
Unit
%

In testing for 2001 to 2026.

Hybrid temperature SKODA_HYBRID_T

  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2001 to 2026.

Hydraulic brake booster active SKODA_HYD_BRK_BST_ACT

  • Service 22DID 1810
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

ID of current driving program SKODA_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

IGA_CYL_KNK, 0 SKODA_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

IGA_CYL_KNK, 1 SKODA_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

IGA_CYL_KNK, 2 SKODA_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

IGA_CYL_KNK, 3 SKODA_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

IGA_IGC, 0 SKODA_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2001 to 2026.

IGA_IGC, 1 SKODA_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2001 to 2026.

IGA_IGC, 2 SKODA_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2001 to 2026.

IGA_IGC, 3 SKODA_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2001 to 2026.

Ignition angle current cylinder, actual value SKODA_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing angle retard, cylinder 1 SKODA_IGNITION_TIMING_ANGLE_RETARD_C1

  • Service 22DID 10E2
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing angle retard, cylinder 2 SKODA_IGNITION_TIMING_ANGLE_RETARD_C2

  • Service 22DID 10E3
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing angle retard, cylinder 3 SKODA_IGNITION_TIMING_ANGLE_RETARD_C3

  • Service 22DID 10E4
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing angle retard, cylinder 4 SKODA_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing angle retard, cylinder 4 SKODA_IGNITION_TIMING_ANGLE_RETARD_C4_V2

  • Service 22DID 10E5
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2001 to 2026.

Injection amount deviation cylinder 1 SKODA_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 1 SKODA_PQ35_INJ_DEV_CYL_1

  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 2 SKODA_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 2 SKODA_PQ35_INJ_DEV_CYL_2

  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 3 SKODA_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 3 SKODA_PQ35_INJ_DEV_CYL_3

  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 4 SKODA_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2001 to 2026.

Injection amount deviation cylinder 4 SKODA_PQ35_INJ_DEV_CYL_4

  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 1 SKODA_INJ_QTY_DEV_CYL_1

  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 2 SKODA_INJ_QTY_DEV_CYL_2

  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 3 SKODA_INJ_QTY_DEV_CYL_3

  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 4 SKODA_INJ_QTY_DEV_CYL_4

  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 5 SKODA_INJ_QTY_DEV_CYL_5

  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation cylinder 6 SKODA_INJ_QTY_DEV_CYL_6

  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 1 SKODA_INJ_QTY_DEV_CYL_1_V2

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 2 SKODA_INJ_QTY_DEV_CYL_2_V2

  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 3 SKODA_INJ_QTY_DEV_CYL_3_V2

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 4 SKODA_INJ_QTY_DEV_CYL_4_V2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 5 SKODA_INJ_QTY_DEV_CYL_5_V2

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injection quantity deviation, cylinder 6 SKODA_INJ_QTY_DEV_CYL_6_V2

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Injector 1 rail pressure calibration point 1 SKODA_PQ35_INJ_1_RAIL_P_1

  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 1 rail pressure calibration point 2 SKODA_INJ_1_RAIL_P_2

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 1 rail pressure calibration point 2 SKODA_PQ35_INJ_1_RAIL_P_2

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2001 to 2026.

Injector 1 rail pressure calibration point 3 SKODA_PQ35_INJ_1_RAIL_P_3

  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2 rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_1

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2 rail pressure calibration point 1 SKODA_PQ35_INJ_2_RAIL_P_1

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2 rail pressure calibration point 2 SKODA_PQ35_INJ_2_RAIL_P_2

  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2 rail pressure calibration point 3 SKODA_PQ35_INJ_2_RAIL_P_3

  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2, rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_1_7E0

  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2, rail pressure calibration point 2 SKODA_INJ_2_RAIL_P_2

  • Service 22DID 10DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 2: rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_CAL_PT_1_146E

  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Injector 2: rail pressure calibration point 2 SKODA_INJ_2_RAIL_P_CAL_PT_2_1474

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Injector 2: rail pressure calibration point 3 SKODA_INJ_2_RAIL_P_CAL_PT_3_147A

  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Injector 3 rail pressure calibration point 1 SKODA_INJ_3_RAIL_P_1

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 3 rail pressure calibration point 1 SKODA_PQ35_INJ_3_RAIL_P_1

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2001 to 2026.

Injector 3 rail pressure calibration point 2 SKODA_PQ35_INJ_3_RAIL_P_2

  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 3 rail pressure calibration point 3 SKODA_PQ35_INJ_3_RAIL_P_3

  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 4 rail pressure calibration point 2 SKODA_PQ35_INJ_4_RAIL_P_2

  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 4 rail pressure calibration point 3 SKODA_INJ_4_RAIL_P_3

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 4 rail pressure calibration point 3 SKODA_PQ35_INJ_4_RAIL_P_3

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2001 to 2026.

Injector 4, rail pressure calibration point 2 SKODA_INJ_4_RAIL_P_2

  • Service 22DID 10D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 5, rail pressure calibration point 1 SKODA_INJ_5_RAIL_P_1

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 5, rail pressure calibration point 2 SKODA_INJ_5_RAIL_P_2

  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 5, rail pressure calibration point 3 SKODA_INJ_5_RAIL_P_3

  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2001 to 2026.

Injector 7: rail pressure calibration point 1 SKODA_INJ_7_RAIL_P_CAL_PT_1

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Injector 7: rail pressure calibration point 2 SKODA_INJ_7_RAIL_P_CAL_PT_2

  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Injector 7: rail pressure calibration point 3 SKODA_INJ_7_RAIL_P_CAL_PT_3

  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2001 to 2026.

Inlet flaps - actual value SKODA_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Inlet flaps - requested value SKODA_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Inside temperature SKODA_INSIDE_T

  • Service 22DID 2613
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−50
Range
-50 to 6503 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature SKODA_IAT_7E0

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature before throttle valve, raw value SKODA_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature in intake manifold SKODA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature in intake manifold SKODA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_V2

  • Service 22DID 149E
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature in intake manifold raw value SKODA_IAT_INT_MANIFOLD_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Intake air temperature raw value SKODA_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Intake camshaft adaptation unit 1 phase length SKODA_PQ35_CAMS_ADAPT_PHASE_1

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 2 SKODA_CAMS_EDGE_POS_2

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 2 SKODA_PQ35_CAMS_EDGE_POS_2

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 3 SKODA_CAMS_EDGE_POS_3

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 3 SKODA_PQ35_CAMS_EDGE_POS_3

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 4 SKODA_PQ35_CAMS_EDGE_POS_4

  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 5 SKODA_PQ35_CAMS_EDGE_POS_5

  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 6 SKODA_PQ35_CAMS_EDGE_POS_6

  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 7 SKODA_PQ35_CAMS_EDGE_POS_7

  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted edge 8 SKODA_PQ35_CAMS_EDGE_POS_8

  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft signal edge position adapted value edge 1 SKODA_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.937 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft, adaptation bias SKODA_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2001 to 2026.

Intake camshaft, adaptation sensor tolerance SKODA_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2001 to 2026.

Intake manifold pressure calculated SKODA_MQB_INT_MAN_P

  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Intake manifold pressure raw value SKODA_INT_MANIFOLD_P_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781.2510000
Range
0 to 19.92
Unit
Raw value

In testing for 2001 to 2026.

Intake manifold pressure raw value SKODA_INT_MANIFOLD_P_RAW_V2

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Intake manifold pressure, commanded SKODA_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Intake manifold pressure, corrected SKODA_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Intake manifold runner control, acknowledgment SKODA_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Intake manifold runner control, activation SKODA_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Intake model air mass flow filtered value SKODA_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Intake phase deviation, actual value SKODA_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2001 to 2026.

Intake phase deviation, after chain replacement SKODA_INT_PHASE_DEV_AFTER

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2001 to 2026.

Intake phase deviation, after repair SKODA_INT_PHASE_DEV_AFTER_REPAIR

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2001 to 2026.

Intake timing chain extension, mileage since last adaptation SKODA_INT_TIM_CHAIN

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Integrated mass of air since engine start SKODA_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2001 to 2026.

Integrated mass of air since the first engine start SKODA_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2001 to 2026.

Intercooler air output temperature SKODA_INTERCOOLER_AIR_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Intercooler air output temperature SKODA_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Intercooler air temperature, raw count SKODA_INTERCOOLER_AIR_T_RAW

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Kick down SKODA_MQB_TCM_KICK_DOWN

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Kilometers driven since last event on K1 SKODA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2001 to 2026.

Kilometers driven since last event on K2 SKODA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2001 to 2026.

Knock retard 2 SKODA_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2001 to 2026.

Knock retard 5 SKODA_KNOCK_RETARD_5

  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 1 SKODA_KNOCK_RETARD_CYL_1

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 2 SKODA_KNOCK_RETARD_CYL_2

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 3 SKODA_KNOCK_RETARD_CYL_3

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 4 SKODA_KNOCK_RETARD_CYL_4

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 5 SKODA_KNOCK_RETARD_CYL_5

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock retard:, cylinder 6 SKODA_KNOCK_RETARD_CYL_6

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.62 °
Unit
°

In testing for 2001 to 2026.

Knock sensor 1 test SKODA_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Knock sensor 2 test SKODA_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Knock sensor 3 test SKODA_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Knock sensor 4 test SKODA_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Knock sensor, cylinder 1 SKODA_KNOCK_SENS_CYL_1

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Knock sensor, cylinder 1 SKODA_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 1 SKODA_KNOCK_SNS_C1_V_MS_V2

  • Service 22DID 120E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 2 SKODA_KNOCK_SENS_CYL_2

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 2 SKODA_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Knock sensor, cylinder 2 SKODA_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 2 SKODA_KNOCK_SNS_C2_V_MS_V2

  • Service 22DID 1211
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 3 SKODA_KNOCK_SENS_CYL_3

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Knock sensor, cylinder 3 SKODA_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 3 SKODA_KNOCK_SNS_C3_V_MS_V2

  • Service 22DID 120F
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 4 SKODA_KNOCK_SENS_CYL_4

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2001 to 2026.

Knock sensor, cylinder 4 SKODA_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Knock sensor, cylinder 4 SKODA_KNOCK_SNS_C4_V_MS_V2

  • Service 22DID 1210
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2001 to 2026.

Lambda output value SKODA_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2001 to 2026.

Lambda value at DPF inlet SKODA_LAMBDA_DPF_INLET

  • Service 22DID 080E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2001 to 2026.

Lambda, actual value SKODA_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2001 to 2026.

Launch control counter SKODA_LAUNCH_CTRL_CNT

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Launch control counter, variant 1 SKODA_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Left central air outlet temperature SKODA_LEFT_CENTRAL_AIR_T

  • Service 22DID 42C5
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Left footwell air outlet temperature SKODA_LEFT_FOOTWELL_AIR_T

  • Service 22DID 42BC
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Left rear footwell air outlet temperature SKODA_LEFT_REAR_FOOTWELL_T

  • Service 22DID 42C1
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Left rear upper air outlet temperature SKODA_LEFT_REAR_HI_AIR_T

  • Service 22DID 42BE
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Left side air outlet temperature SKODA_LEFT_SIDE_AIR_OUTLET_T

  • Service 22DID 42C3
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Leg deflector temperature SKODA_CLIMATE_LEG_DEFL_T

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Limitation, smoke SKODA_LIM_SMOKE

  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Limitation, torque SKODA_LIM_TQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Long term fuel trim at idle - direct injection SKODA_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 1535 %
Unit
%

In testing for 2001 to 2026.

Long term fuel trim at idle, direct injection SKODA_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2001 to 2026.

Long term fuel trim at idle, port injection SKODA_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2001 to 2026.

Long term throttle adaptation to MAF sensor SKODA_LONG_TERM_THROTTLE

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610351
Range
0 to 3.99 %
Unit
%

In testing for 2001 to 2026.

Long-term adaptation of intake manifold injection SKODA_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Long-term adaptation of intake manifold injection at idle SKODA_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Lost torque adaptation A/C + driving mode SKODA_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Lost torque adaptation driving mode SKODA_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Low press. EGR closing SKODA_LOW_PRESS_EGR

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×252048
Range
0 to 799 %
Unit
%

In testing for 2001 to 2026.

Low press. EGR closing SKODA_LOW_PRESS_EGR_V2

  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Low pressure EGR closing SKODA_LOW_P_EGR_CLOSING

  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-252048+100
Range
-699 to 100 %
Unit
%

In testing for 2001 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation SKODA_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

M009, desired solenoid out 10 SKODA_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

M009, desired solenoid out 11 SKODA_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

M009, desired solenoid out 12 SKODA_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

M009, desired solenoid out 13 SKODA_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

M009, desired solenoid out 14 SKODA_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Main cat oxygen storage capacity age correction factor SKODA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2001 to 2026.

Main catalyst aging factor SKODA_MAIN_CAT_AGING

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245818054700000
Range
0 to 0.199
Unit
Number

In testing for 2001 to 2026.

Main catalytic converter oxygen storage capacity age correction factor SKODA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR_V2

  • Service 22DID 14F9
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2001 to 2026.

Main injection duration SKODA_PQ35_MAIN_INJ_DURATION

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Main injection start position SKODA_PQ35_MAIN_INJ_START

  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Main injection, duration SKODA_MAIN_INJ_DUR

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

Main injection, start SKODA_MAIN_INJ_START

  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Manifold absolute pressure, raw value SKODA_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Manual engine starts counter SKODA_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Mass air flow over throttle valve SKODA_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Mass air flow through throttle SKODA_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Mass air flow, commanded SKODA_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Mass airflow sensor 1 bank 1 raw value SKODA_MAF_1_B1_RAW

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2001 to 2026.

Mass flow through throttle valve SKODA_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2001 to 2026.

Max permissible engine torque SKODA_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Maximum ECU temperature SKODA_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Maximum filling correction factor from knock control SKODA_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 2001 to 2026.

Maximum oil level for the service interval SKODA_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Mean engine air mass SKODA_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Mean engine air mass SKODA_PQ35_MEAN_AIR_MASS

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2001 to 2026.

Mean injection quantity SKODA_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2001 to 2026.

Mean injection quantity SKODA_MEAN_INJ_QUANTITY

  • Service 22DID 1139
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.01
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Mean injection quantity SKODA_MEAN_INJ_QUANTITY_2

  • Service 22DID 1139
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Median injection timing SKODA_MEDIAN_INJ_TIM

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2001 to 2026.

Mileage with ECU installed SKODA_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Minimum oil level for the service interval SKODA_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Misfires / 1000 revolutions, cylinder 1 SKODA_MISFIRES_1000REV_C1

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires / 1000 revolutions, cylinder 2 SKODA_MISFIRES_1000REV_C2

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires / 1000 revolutions, cylinder 3 SKODA_MISFIRES_1000REV_C3

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires / 1000 revolutions, cylinder 4 SKODA_MISFIRES_1000REV_C4

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires 4 SKODA_MIS_4_7E0

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 1 SKODA_MIS_CNT_1

  • Service 22DID 147E
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 2 SKODA_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 3 SKODA_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 4 SKODA_MIS_CNT_4

  • Service 22DID 147F
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 5 SKODA_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires counter:, cylinder 6 SKODA_MIS_CNT_6

  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires for 1000 revolutions, cylinder 2 SKODA_MIS_1000_REVOLUTIONS_2

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires for 1000 revolutions, cylinder 5 SKODA_MIS_1000_REVOLUTIONS_5

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection SKODA_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 2 SKODA_MIS_PER_1000_2

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection SKODA_MIS_PER_1000_2_7E0

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 3 SKODA_MIS_PER_1000_3

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection SKODA_MIS_PER_1000_3_7E0

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection SKODA_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires total SKODA_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires total SKODA_MISFIRES_TOTAL

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 1 SKODA_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 1 SKODA_MISFIRES_C1

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 1 SKODA_MISFIRES_C1_FC00

  • Service 22DID 2966
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 2 SKODA_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 2 SKODA_MISFIRES_C2

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 2 SKODA_MISFIRES_C2_V2

  • Service 22DID 2969
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 3 SKODA_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 3 SKODA_MISFIRES_C3

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 3 SKODA_MISFIRES_C3_ECM

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 3 SKODA_MISFIRES_C3_FC00

  • Service 22DID 2967
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 4 SKODA_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 4 SKODA_MISFIRES_C4

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires, cylinder 4 SKODA_MISFIRES_C4_V2

  • Service 22DID 2968
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Mixture adaptation factor at partial load SKODA_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Motor temperature SKODA_DIFF_MOTOR_T

  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−50
Range
-50 to 460 °C
Unit
°C

In testing for 2001 to 2026.

N_32 SKODA_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2001 to 2026.

NL_PRE, 0 SKODA_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2001 to 2026.

NL_PRE, 1 SKODA_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2001 to 2026.

NL_PRE, 2 SKODA_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2001 to 2026.

NL_PRE, 3 SKODA_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2001 to 2026.

Number of injections SKODA_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded SKODA_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Number of warnings due to increased centrifugal oil temperature SKODA_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

NV energy requirement SKODA_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2001 to 2026.

Oil ash limit SKODA_OIL_ASH_LIM

  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Oil ash residue SKODA_OIL_ASH_RESIDUE

  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Oil ash residue SKODA_OIL_ASH_RESIDUE_7E0

  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Oil ash residue SKODA_OIL_ASH_RESIDUE_V2

  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×3.052e-7
Range
0 to 1310
Unit
Raw value

In testing for 2001 to 2026.

Oil dynamic average SKODA_OIL_DYNAMIC_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

In testing for 2001 to 2026.

Oil dynamic average measurement SKODA_PQ35_OIL_DYN_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil fill level SKODA_OIL_FILL_LEVEL

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2001 to 2026.

Oil last dynamic measurement SKODA_PQ35_OIL_DYN_LAST

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil last dynamic value SKODA_OIL_LAST_DYNAMIC

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

In testing for 2001 to 2026.

Oil level SKODA_OIL_LEVEL_2

  • Service 22DID 11BA
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262
Unit
Raw value

In testing for 2001 to 2026.

Oil level method 1 SKODA_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2001 to 2026.

Oil level method 2 SKODA_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2001 to 2026.

Oil level method 3 SKODA_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2001 to 2026.

Oil level test method 1 SKODA_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Oil level test method 2 SKODA_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Oil level test method 3 SKODA_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Oil level, average dynamic value SKODA_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil level, last dynamic value SKODA_OIL_LEVEL_LAST

  • Service 22DID 15B8
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

In testing for 2001 to 2026.

Oil level, last valid dynamic value SKODA_OIL_LEVEL_LAST_VALID

  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2001 to 2026.

Oil level, static measured SKODA_OIL_LEVEL_STATIC_7E0

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil level, static measurement SKODA_OIL_LEVEL_STATIC

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2001 to 2026.

Oil maximum level SKODA_PQ35_OIL_LVL_MAX

  • Service 22DID 11C4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil minimum level SKODA_PQ35_OIL_LVL_MIN

  • Service 22DID 11C5
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2001 to 2026.

Oil p SKODA_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2001 to 2026.

Oil pressure 1 SKODA_OIL_P_1

  • Service 22DID 2B05
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2001 to 2026.

Oil pressure 2 SKODA_OIL_P_2

  • Service 22DID 2B06
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2001 to 2026.

Oil pressure actual SKODA_MQB_TCM_EOP_ACTUAL

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

In testing for 2001 to 2026.

Oil pressure actual current SKODA_MQB_TCM_EOP_ACTUAL_I

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2001 to 2026.

Oil pressure control valve activation pulse duty factor SKODA_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Oil pressure control valve, activation pulse duty factor SKODA_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Oil pressure sensor raw value SKODA_OIL_P_SENS_RAW_7E0

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2001 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status SKODA_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil pressure sensor, raw value SKODA_OIL_P_SENS_RAW

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Oil pressure switch activation, high pressure SKODA_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil pressure switch for high pressure, closed SKODA_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Oil pressure switch for low pressure, closed SKODA_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Oil pressure switch for piston-cooling jets, closed SKODA_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil pressure switch valve activation SKODA_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil pressure target SKODA_OIL_P_TGT

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2001 to 2026.

Oil pressure target SKODA_OIL_P_TGT_7E0

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2001 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio SKODA_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Oil pressure valve switch, control SKODA_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil pressure, actual value SKODA_OIL_P_ACT

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2001 to 2026.

Oil pressure, actual value SKODA_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Oil pressure, actual value SKODA_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2001 to 2026.

Oil sensor temperature 1 SKODA_OIL_SENS_T_1

  • Service 22DID 2B03
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Oil sensor temperature 2 SKODA_OIL_SENS_T_2

  • Service 22DID 2B04
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Oil sump temperature SKODA_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Oil temp 2 SKODA_ENGINE_OIL_T_2

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Oil temperature SKODA_DIFF_OIL_T

  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2−50
Range
-50 to 460 °C
Unit
°C

In testing for 2001 to 2026.

Oil temperature SKODA_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Oil temperature SKODA_PQ35_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−58
Range
-58 to 197 °C
Unit
°C

In testing for 2001 to 2026.

Oil temperature variant SKODA_PQ35_OIL_T_2

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Oil temperature variant SKODA_PQ46_OIL_T_2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Oil thermal wear SKODA_OIL_WEAR

  • Service 22DID 224B
  • Module714 → 77E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Oil warning threshold SKODA_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2001 to 2026.

Open cam shaft angle at quantity control valve SKODA_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2001 to 2026.

Open camshaft angle at quantity control valve SKODA_OPEN_CAM_ANG_QTY

  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2001 to 2026.

Outside temperature SKODA_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature, system calculated SKODA_OUTSIDE_T_SYSTEM

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Outside temperature, system calculated SKODA_TRON_OUTSIDE_T_SYSTEM

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

In testing for 2001 to 2026.

Overall energy balance SKODA_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2001 to 2026.

Oxygen control, adaptation value at part. load SKODA_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature SKODA_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2001 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature SKODA_OXYGEN_SNS_1_BANK_1_CERAMIC_T_V2

  • Service 22DID 1290
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262 °C
Unit
°C

In testing for 2001 to 2026.

Oxygen sensor 1 bank 1 lambda value SKODA_PQ35_O2_SEN_1_LAMBDA

  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Number

In testing for 2001 to 2026.

Particle filter, field regeneration request status SKODA_PARTICLE_FLT_FIELD

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Particle sensor, cleaning deviation reaction time SKODA_PARTICLE_SENS

  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76
Unit
Number

In testing for 2001 to 2026.

Particle sensor, exhaust temperature SKODA_PARTICLE_SENS_EXH_T

  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Particle sensor, soot volume in exhaust SKODA_PARTICLE_SENS_SOOT

  • Service 22DID 44F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Particle sensor, surface temperature SKODA_PARTICLE_SENS_T

  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16−273.15
Range
-2321 to 1774 °C
Unit
°C

In testing for 2001 to 2026.

Particle sensor, time in op.mode measurement SKODA_PARTICLE_SENS_TIME

  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2001 to 2026.

Particulate filter air pressure sensor raw value SKODA_MQB_DPF_AIR_P_SENSOR_RAW_VALUE

  • Service 22DID 162F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Particulate filter differential pressure, dynamic offset SKODA_DPF_DIFF_P_DYNAMIC_OFFSET

  • Service 22DID 15B8
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Particulate filter differential pressure, filtered SKODA_PF_DIFF_P_FILTERED

  • Service 22DID 1040
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−5000
Range
-5000 to 11383.75
Unit
Raw value

In testing for 2001 to 2026.

Pilot injection 1 duration SKODA_PQ35_PRE_INJ_1_DURATION

  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Pilot injection 1 start position SKODA_PQ35_PRE_INJ_1_START

  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Pilot injection 2 start SKODA_PQ35_PRE_INJ_2_START

  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Pilot injection 3, start SKODA_PRE_INJ_3_START

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219731000000
Range
-720 to 719 °
Unit
°

In testing for 2001 to 2026.

Piston cooling nozzles, control SKODA_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Piston-cooling jets, activation SKODA_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Port injection injections counter SKODA_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Post injection 1 SKODA_POST_INJ_1

  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Post injection 1 SKODA_POST_INJ_1_7E0

  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2001 to 2026.

Post injection 1, quantity specified value SKODA_POST_INJ_1_QTY_SPEC

  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2001 to 2026.

Post injection 1: quantity specified value SKODA_PQ35_POST_INJ_1_QTY_SPEC

  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Post injection 2 SKODA_POST_INJ_2_7E0

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2001 to 2026.

Post injection 2 SKODA_POST_INJ_2_V2

  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Post injection 2, quantity specified value SKODA_POST_INJ_2_QTY_SPEC

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2001 to 2026.

Post injection 2: quantity specified value SKODA_PQ35_POST_INJ_2_QTY_SPEC

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Post injection 3 SKODA_POST_INJ_3_7E0

  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2001 to 2026.

Post injection 3 SKODA_POST_INJ_3_V2

  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2001 to 2026.

Post injection 3, quantity specified value SKODA_POST_INJ_3_QTY_SPEC

  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2001 to 2026.

Post injection 3: quantity specified value SKODA_PQ35_POST_INJ_3_QTY_SPEC

  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Post-injection 1 duration SKODA_PQ35_POST_INJ_1_DURATION

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 1 start position SKODA_PQ35_POST_INJ_1_START

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Post-injection 1, duration SKODA_POST_INJ_1_DUR

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 1, start SKODA_POST_INJ_1_START

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Post-injection 2 duration SKODA_PQ35_POST_INJ_2_DURATION

  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 2 start position SKODA_PQ35_POST_INJ_2_START

  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Post-injection 2, activation duration SKODA_POST_INJ_2

  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 2, duration SKODA_POST_INJ_2_DUR

  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 2, start SKODA_POST_INJ_2_START

  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Post-injection 3 activation duration SKODA_POST_INJ_3_ACTIVATION_DURATION

  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Post-injection 3 start position SKODA_PQ35_POST_INJ_3_START

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2001 to 2026.

Post-injection 3, activation start SKODA_POST_INJ_3

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Power electronics internal supply voltage 1 SKODA_PE_SUPPLY_V1

  • Service 22DID 466C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Power electronics internal supply voltage 2 SKODA_PE_SUPPLY_V2

  • Service 22DID 466B
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Power electronics phase U transistor temperature SKODA_PE_IGBT_U_T

  • Service 22DID 4664
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

Power electronics phase V transistor temperature SKODA_PE_IGBT_V_T

  • Service 22DID 4663
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

Power electronics phase W transistor temperature SKODA_PE_IGBT_W_T

  • Service 22DID 4662
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2001 to 2026.

Power electronics traction voltage SKODA_PE_HV_V

  • Service 22DID 4675
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2001 to 2026.

Power electronics transistor supply voltage SKODA_PE_IGBT_SUPPLY_V

  • Service 22DID 465A
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2001 to 2026.

Pre-injection 1, activation start SKODA_PRE_INJ_1_ACTIVATION

  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Pre-injection 2, activation start SKODA_PRE_INJ_2_ACTIVATION

  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Pre-injection 3, activation duration SKODA_PRE_INJ_3_ACTIVATION

  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2001 to 2026.

Pre-injection 3, activation start SKODA_PRE_INJ_3_ACTIVATION_START

  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Preheat time SKODA_PREHEAT_TIME

  • Service 22DID 111F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 ms
Unit
ms

In testing for 2001 to 2026.

Pressure before throttle valve - actual value SKODA_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2001 to 2026.

Pressure before throttle valve - sensor measured SKODA_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2001 to 2026.

Pressure sensor 1 temperature SKODA_P_SENS_1_T

  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Pressure sensor 2 temperature SKODA_P_SENS_2_T

  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Pressure supply actual pressure SKODA_MQB_DQ200_P_SUPPLY_ACTUAL_P

  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Pressure supply actual pressure analog digital value SKODA_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 SKODA_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2001 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 SKODA_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2001 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 SKODA_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2001 to 2026.

Radiator fan 1, commanded duty SKODA_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Radiator fan 2, commanded duty SKODA_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

Radiator fan actual duty SKODA_CLIMATE_RAD_FAN_ACT_DUTY

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator fan commanded duty SKODA_CLIMATE_RAD_FAN_CMD_DUTY

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator fan duty SKODA_RADIATOR_FAN_DUTY

  • Service 22DID 2055
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Radiator outlet coolant temperature commanded SKODA_PQ35_RAD_COOL_T_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Radiator output coolant temp: actual SKODA_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2001 to 2026.

Radiator output coolant temperature, actual SKODA_RADIATOR_OUTPUT_ECT_ACT

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Radiator output coolant temperature, commanded SKODA_RADIATOR_OUTPUT_ECT_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Rated drive torque SKODA_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2001 to 2026.

Reached maximum temperature SKODA_REACHED_MAXIMUM_T

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Rear cat converter temperature, main catalytic converter model value SKODA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Rear catalytic converter temperature, main catalytic converter model value SKODA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE_V2

  • Service 22DID 1272
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2001 to 2026.

Rear deflector temperature SKODA_CLIMATE_RR_DEFL_T

  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

In testing for 2001 to 2026.

Reducing agent tank volume, act. value filtered SKODA_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 2001 to 2026.

Refrigerant pressure SKODA_CLIMATE_REFRIG_P

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

In testing for 2001 to 2026.

Refrigerant pressure SKODA_REFRIGERANT_P

  • Service 22DID 2605
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

In testing for 2001 to 2026.

Regen. duration SKODA_REGEN_DUR

  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val6000
Range
0 to 715827 min
Unit
min

In testing for 2001 to 2026.

Regeneration duration SKODA_REGEN_DUR_V2

  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val60
Range
0 to 1092.25 min
Unit
min

In testing for 2001 to 2026.

Regulation factor total SKODA_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2001 to 2026.

Relative load value SKODA_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 2001 to 2026.

Relay for reserve coolant pump status SKODA_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Requested torque, amount for auxiliary units SKODA_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Reserve torque SKODA_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Result of crankcase ventilation test, fail SKODA_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Result of crankcase ventilation test, successful SKODA_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Right central air outlet temperature SKODA_RIGHT_CENTRAL_AIR_T

  • Service 22DID 42C6
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Right footwell air outlet temperature SKODA_RIGHT_FOOTWELL_AIR_T

  • Service 22DID 42BD
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Right rear footwell air outlet temperature SKODA_RIGHT_REAR_FOOTWELL_T

  • Service 22DID 42C2
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Right rear upper air outlet temperature SKODA_RIGHT_REAR_HI_AIR_T

  • Service 22DID 42C0
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Right side air outlet temperature SKODA_RIGHT_SIDE_AIR_T

  • Service 22DID 42C4
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−50
Range
-50 to 4045 °C
Unit
°C

In testing for 2001 to 2026.

Rotor position sensor cosine amplitude SKODA_ROTOR_COS_AMP_V

  • Service 22DID 4E91
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Rotor position sensor cosine offset SKODA_ROTOR_COS_OFS_V

  • Service 22DID 4E93
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Rotor position sensor cosine track SKODA_ROTOR_COS

  • Service 22DID 4661
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Rotor position sensor sine amplitude SKODA_ROTOR_SIN_AMP_V

  • Service 22DID 4E90
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Rotor position sensor sine track SKODA_ROTOR_SIN

  • Service 22DID 4660
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Rotor position sensor sine voltage SKODA_ROTOR_SIN_V

  • Service 22DID 4E92
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2001 to 2026.

Rotor temperature model SKODA_ROTOR_T_MODEL

  • Service 22DID 2CCC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Route data, active SKODA_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Second pilot injection, duration SKODA_PRE_INJ_2_DURATION

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2001 to 2026.

Second pilot injection, start SKODA_PRE_INJ_2_START

  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2001 to 2026.

Secondary air injection sensor 1 SKODA_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

SEG_AD_MMV_ER_H, 0 SKODA_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_H, 2 SKODA_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_H, 3 SKODA_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_L, 0 SKODA_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_L, 2 SKODA_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_L, 3 SKODA_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_MID, 0 SKODA_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_MID, 1 SKODA_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER_MID, 2 SKODA_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER, 1 SKODA_SEG_AD_MMV_ER_1

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER, 2 SKODA_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

SEG_AD_MMV_ER, 3 SKODA_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2001 to 2026.

Sensor for particle filter differential pressure, raw value SKODA_SENS_PARTICLE_FLT_P

  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Service interval extension, max oil level SKODA_WIV_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

In testing for 2001 to 2026.

Service interval extension, min oil level SKODA_WIV_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 mm
Unit
mm

In testing for 2001 to 2026.

Service limit SKODA_SERVICE_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2001 to 2026.

Service limit SKODA_SERVICE_LIM_7E0

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Service limit SKODA_SERVICE_LIM_7E0_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Service limit value SKODA_PQ35_SRV_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Service regeneration current duration SKODA_SERVICE_REGEN

  • Service 22DID 11C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672 s
Unit
s

In testing for 2001 to 2026.

Shunt temperature SKODA_BMS_SHUNT_T

  • Service 22DID 180F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

SIM card, SIM card in main unit SKODA_SIM_CARD_SIM_CARD

  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Simulated DPF temperature SKODA_SIMULATED_DPF_T

  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2001 to 2026.

Smoke limit SKODA_PQ35_LIM_SMOKE

  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Soot mass calculated SKODA_SOOT_MASS_CALC

  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Soot mass measured SKODA_SOOT_MASS_MEAS_V2

  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127
Unit
Raw value

In testing for 2001 to 2026.

Spark efficiency deviation at idle SKODA_SPARK_EFFICIENCY_DEV

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×7811000
Range
0 to 199 %
Unit
%

In testing for 2001 to 2026.

Spark efficiency deviation at idle, maximum SKODA_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Spark efficiency deviation at part load SKODA_SPARK_EFF_DEV

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×78.1100
Range
0 to 199.14 %
Unit
%

In testing for 2001 to 2026.

Spark efficiency deviation at part load SKODA_SPARK_EFF_DEV_PART

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×78.1100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Spark efficiency deviation at part load SKODA_SPARK_EFFICIENCY_DEV_V2

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×7811000
Range
0 to 199 %
Unit
%

In testing for 2001 to 2026.

Spark efficiency deviation at part load, maximum SKODA_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Static torque limitation SKODA_STATIC_TQ_LIM

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Status CC ECU, temperature. st.disc SKODA_STAT_CC_ECU_T_ST

  • Service 22DID 110A
  • Module70F → 779
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Stop signal switch SKODA_MQB_TCM_STOP_SIGNAL_SWITCH

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Sum of misfires counter SKODA_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Tank fill level diagnostic reference value SKODA_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

TCO_1_ST SKODA_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

TCO_1_SYS SKODA_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Temperature after evaporator SKODA_CLIMATE_T_AFTER_EVAP

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val3
Range
-42.624 to 42.291 °C
Unit
°C

In testing for 2001 to 2026.

Temperature after evaporator SKODA_PQ35_EVAP_OUT_T

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.333
Range
-42.624 to 42.291 °C
Unit
°C

In testing for 2001 to 2026.

Temperature at air conditioner heat exchanger output SKODA_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Temperature sensor 14 SKODA_T_SENS_14

  • Service 22DID 1EBB
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Temperature sensor for engine temperature management SKODA_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Temperature sensor for engine temperature management, target value SKODA_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

Temperature status, controller SKODA_STAT_NIA_T

  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 136 to 151 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Temperature status, RPS SKODA_STAT_NIA_T_RPS

  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Temperature status, SBC SKODA_STAT_NIA_T_SBC

  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Temperature, electric drive inflow coolant SKODA_ELEC_DRIVE_INFLOW_COOLANT_T

  • Service 22DID 4FAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Temperature, motor SKODA_MOTOR_T_V2

  • Service 22DID 4672
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2001 to 2026.

Test of catalytic converter status, canceled SKODA_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Test of catalytic converter, measured value SKODA_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2001 to 2026.

Thermal load of AWD drive pump SKODA_THERMAL_LOAD_AWD

  • Service 22DID 2B09
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2001 to 2026.

Thermostat, actual SKODA_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Thermostat, commanded SKODA_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Throttle regulator nominal value SKODA_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Throttle valve adapter position SKODA_PQ35_THROT_VALVE_ADAPT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Throttle valve adapter, actual value SKODA_THROTTLE_VLV_ADAPTER_ACT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2001 to 2026.

TI_1_MPI, 0 SKODA_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_1_MPI, 1 SKODA_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_1_MPI, 2 SKODA_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_1_MPI, 3 SKODA_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_1, 1 SKODA_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_1, 2 SKODA_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_1, 3 SKODA_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_2, 0 SKODA_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_2, 1 SKODA_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_2, 2 SKODA_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_2, 3 SKODA_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_3, 0 SKODA_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_3, 1 SKODA_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_3, 2 SKODA_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

TI_MES4_PLS_3, 3 SKODA_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2001 to 2026.

Time in run-on after shutdown SKODA_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2001 to 2026.

Time since last regen. SKODA_TIME_SINCE_REGEN

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val60
Range
0 to 71582788 min
Unit
min

In testing for 2001 to 2026.

Time since last regeneration SKODA_TIME_SINCE_REGEN_V2

  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2001 to 2026.

Time since reset SKODA_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2001 to 2026.

Time with transmission fluid above 135 degrees SKODA_ANALYSIS_40_ATF_T_135_C

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Time with transmission fluid at 65 to 80 degrees SKODA_ANALYSIS_40_ATF_T_65_C_80_C

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Time with transmission fluid at 80 to 110 degrees SKODA_ANALYSIS_40_ATF_T_80_C_110_C

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Time with transmission fluid at 110 to 135 degrees SKODA_ANALYSIS_40_ATF_T_110_C_135_C

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Time with transmission fluid below 65 degrees SKODA_ANALYSIS_40_ATF_T_65_C

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val5
Range
0 to 858993459 s
Unit
s

In testing for 2001 to 2026.

Timing angle retardation cylinder 1 SKODA_TIMING_ANGLE_RETARDATION_CYL_1

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

Timing angle retardation cylinder 2 SKODA_TIMING_ANGLE_RETARDATION_CYL_2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

Timing angle retardation cylinder 3 SKODA_TIMING_ANGLE_RETARDATION_CYL_3

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

Timing angle retardation cylinder 4 SKODA_TIMING_ANGLE_RETARDATION_CYL_4

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2001 to 2026.

Timing deviation after chain replacement, exhaust bank 1 SKODA_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Timing deviation after chain replacement, intake bank 1 SKODA_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Timing deviation after other repairs, intake bank 1 SKODA_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Timing deviation after other repairs, intake bank 1 SKODA_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Timing deviation current value exhaust bank 1 SKODA_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Timing deviation current value intake bank 1 SKODA_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2001 to 2026.

Torque converter clutch status SKODA_TC_STS

  • Service 22DID 7078
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2001 to 2026.

Torque converter slip SKODA_TORQUE_CONVERTER_SLIP_FC00

  • Service 22DID 2131
  • ModuleFC00 → FE0077
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Torque converter: torque loss SKODA_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque converter: torque loss SKODA_TORQUE_CONVERTER_TORQUE_LOSS_V2

  • Service 22DID 7053
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque distribution SKODA_TQ_DISTRIBUTION

  • Service 22DID 2B0A
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque factor SKODA_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Torque increase request from ESP SKODA_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limit SKODA_PQ35_LIM_TRQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limitation SKODA_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limitation SKODA_TORQUE_LIMITATION_V2

  • Service 22DID 203F
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limitation SKODA_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limitation SKODA_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque limitation, clutch protection SKODA_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation SKODA_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation at idle SKODA_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation, A/C compressor SKODA_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation, A/C compressor SKODA_TQ_LOSS_ADPT_AC_COMP_V2

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque reduction due to exhaust temperature SKODA_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.276
Unit
Number

In testing for 2001 to 2026.

Torque reduction request from ESP SKODA_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque request, sum of auxiliary aggregate SKODA_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque transmitting function SKODA_TQ_TRANSMITTING_V2

  • Service 22DID 2105
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×496250
Range
0 to 513
Unit
Number

In testing for 2001 to 2026.

Torque transmitting function, ratio SKODA_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2001 to 2026.

Total mass of gasoline and ethyl alcohol in oil SKODA_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 2001 to 2026.

Transmission fluid temperature SKODA_ATF_T_FC00

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • ModuleFC00 → FE0077
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, calculated SKODA_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, calculated SKODA_ATF_T_CALCULATED_V2

  • Service 22DID 704E
  • ModuleFC00 → FE0077
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, dual-clutch SKODA_ATF_T_DUAL_CLU

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, maximum reached SKODA_ATF_T_MAX_REACHED

  • Service 22DID 704F
  • ModuleFC00 → FE0077
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, modeled max reached SKODA_ATF_T_MODELED_MAX_REACHED_V2

  • Service 22DID 7051
  • ModuleFC00 → FE0077
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2001 to 2026.

Transmission fluid temperature, modeled maximum reached SKODA_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2001 to 2026.

Transmission read 1196, raw count SKODA_TCM_1196_RAW

  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Turbine actuator 1 bank 1 activation SKODA_PQ35_TURB_ACT_1_B1

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Turbine actuator 1 bank 1: activation SKODA_ACT

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation SKODA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation SKODA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Valve lift system, result of last switch, intake SKODA_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Valve lift system, valve lift, exhaust SKODA_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Valve lift system, valve lift, intake SKODA_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Valve timing, the difference between the, actual and the set angle SKODA_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 2001 to 2026.

Variable valve timing, intake, bank 1, regulation SKODA_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Variable valve timing, intake, bank 1, switch on SKODA_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Washer nozzle heater active SKODA_HTR_NOZZLE

  • Service 22DID 1945
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Wear index SKODA_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2001 to 2026.

Wear index %, 0=new engine SKODA_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

DPF

Diesel particulate filter ash load limit SKODA_MQB_DPF_ASH_LOAD_LIMIT

  • Service 22DID 1ABF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×78.12510000
Range
0 to 511.992
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter diff pressure: raw value 1 SKODA_MQB_DPF_DIFF_P_RAW_VALUE_1

  • Service 22DID 269A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter diff pressure: raw value 2 SKODA_MQB_DPF_DIFF_P_RAW_VALUE_2

  • Service 22DID 269B
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter field regeneration lock status SKODA_DPF_FIELD_REGEN_LOCK

  • Service 22DID 11C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter field regeneration request SKODA_MQB_DPF_FIELD_REGEN_REQUEST

  • Service 22DID 1AC2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter fuel consumption since last regeneration SKODA_MQB_DPF_FUEL_CONSUMPTION_SINCE_LAST_REGEN

  • Service 22DID 1AC1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter fuel consumption since last regeneration SKODA_PQ35_DPF_FUEL_CON_REGEN

  • Service 22DID 115A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter inlet lambda value SKODA_MQB_DPF_INLET_LAMBDA_VALUE

  • Service 22DID 1AD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter oil ash volume SKODA_PQ35_DPF_OIL_ASH_VOL

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter regeneration level current SKODA_MQB_DPF_REGEN_LEVEL_I

  • Service 22DID 1AD3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration release requirement SKODA_MQB_DPF_REGEN_RELEASE_REQUIREMENT

  • Service 22DID 1AD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration status SKODA_MQB_DPF_REGEN_STATUS

  • Service 22DID 1AD4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter regeneration time counter SKODA_MQB_DPF_REGEN_TIME_COUNTER

  • Service 22DID 1AC0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×640010000
Range
0 to 41942.4 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter service regeneration current duration SKODA_MQB_DPF_SERVICE_REGEN_I_DURATION

  • Service 22DID 1AC4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×640010000
Range
0 to 41942.4 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter soot mass measured SKODA_MQB_DPF_SOOT_MASS_MEASURED

  • Service 22DID 1ABE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter statistics average drive cycle time during charge cycle SKODA_MQB_DPF_STATISTICS_AVERAGE_DRIVE_CYCLE_TIME_DURING_CHARGE_CYCLE

  • Service 22DID 1ACC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1600100
Range
0 to 4080 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter statistics error status SKODA_MQB_DPF_STATISTICS_ERROR_STATUS

  • Service 22DID 1ACA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics exhaust temperature regulation average value SKODA_MQB_DPF_STATISTICS_EXHAUST_T_REGULATION_AVERAGE_VALUE

  • Service 22DID 1AC7
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.98127
Range
-1.99 to 1.98
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics number of interrupted regenerations SKODA_MQB_DPF_STATISTICS_NUMBER_INTERRUPTED_REGENS

  • Service 22DID 1AC9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics regeneration blocked status SKODA_MQB_DPF_STATISTICS_REGEN_BLOCKED_STATUS

  • Service 22DID 1AC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics regeneration request SKODA_MQB_DPF_STATISTICS_REGEN_REQUEST

  • Service 22DID 1AC5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics regeneration time SKODA_MQB_DPF_STATISTICS_REGEN_TIME

  • Service 22DID 1ACD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6400100
Range
0 to 16320 s
Unit
s

In testing for 2001 to 2026.

Diesel particulate filter statistics regeneration time slice not possible in charge cycle SKODA_MQB_DPF_STATISTICS_REGEN_TIME_SLICE_NOT_POSS_IN_CHARGE_CYCLE

  • Service 22DID 1ACE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.498255
Range
0 to 0.498
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter statistics route in charge cycle SKODA_MQB_DPF_STATISTICS_ROUTE_IN_CHARGE_CYCLE

  • Service 22DID 1ACB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×800100
Range
0 to 2040 km
Unit
km

In testing for 2001 to 2026.

Diesel particulate filter time since last regeneration SKODA_MQB_DPF_TIME_SINCE_LAST_REGEN

  • Service 22DID 1AC3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×127.99865535
Range
0 to 127.998 h
Unit
h

In testing for 2001 to 2026.

Diesel particulate filter unburned fuel calculated SKODA_MQB_DPF_UNBURNED_FUEL_CALCULATED

  • Service 22DID 18BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter, charge limit for service regeneration while driving SKODA_MQB_DPF_CHARGE_LIMIT_SERVICE_REGEN_WHILE_DRIVING

  • Service 22DID 1ABB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter, charge limit over-charge SKODA_MQB_DPF_CHARGE_LIMIT_OVER_CHARGE

  • Service 22DID 1ABC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Diesel particulate filter, distance since last regeneration SKODA_MQB_DPF_DISTANCE_SINCE_LAST_REGEN

  • Service 22DID 1ABA
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Distance since last regeneration SKODA_PQ35_DIST_LAST_REGEN

  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Particulate filter soot mass calculated SKODA_DPF_SOOT_MASS_CALCULATED

  • Service 22DID 2609
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Regeneration duration SKODA_PQ35_REGEN_DUR

  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2001 to 2026.

Service regeneration status SKODA_SRV_REGEN_STAT

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Soot index SKODA_PQ35_SOOT_IDX

  • Service 22DID 1354
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2001 to 2026.

Soot mass calculated SKODA_PQ35_SOOT_MASS_CALC

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2001 to 2026.

Soot mass measured SKODA_SOOT_MASS_MEAS

  • Service 22DID 114E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2001 to 2026.

Unidentified engine value, raw count SKODA_ENG_114F_RAW

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

EGR

Exhaust gas recirculation 2: filter press loss, modeled SKODA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2001 to 2026.

Exhaust gas recirculation 2: filter press loss, simulated SKODA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2001 to 2026.

High press EGR closing v1 SKODA_PQ35_HIGH_P_EGR_CLOSING_VAR_1

  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

High press EGR closing v2 SKODA_PQ35_HIGH_P_EGR_CLOSING_VAR_2

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Water pump

Water pump power SKODA_PTC_PUMP_PWR

  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200
Unit
Raw value

In testing for 2001 to 2026.

Water pump RPM SKODA_PTC_PUMP_RPM

  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×300
Range
0 to 76500 rpm
Unit
rpm

In testing for 2001 to 2026.

Fluids

Automatic transmission fluid temperature SKODA_ATF_T

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Oil level SKODA_OIL_LEVEL

  • Service 22DID 11BA
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2001 to 2026.

Oil level warning threshold SKODA_OIL_LEVEL_WARN

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2001 to 2026.

Oil level, critical SKODA_OIL_CRIT

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2001 to 2026.

Oil level, max, raw count SKODA_OIL_MAX

  • Service 22DID 11C4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Oil level, min, raw count SKODA_OIL_MIN

  • Service 22DID 11C5
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Fuel

Activation of fuel pump electronics SKODA_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Counter of fuel entry in oil SKODA_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter fuel consumption since last regeneration, bank 1 SKODA_DPF_FUEL_CONS_SINCE_1

  • Service 22DID 14B6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter fuel consumption since last regeneration, bank 2 SKODA_DPF_FUEL_CONS_SINCE_2

  • Service 22DID 1461
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 L
Unit
L

In testing for 2001 to 2026.

Diesel particulate filter unburned fuel calculated SKODA_DPF_UNBURNED_FUEL_CALC

  • Service 22DID 44F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76
Unit
Number

In testing for 2001 to 2026.

Diesel particulate filter, fuel consumption since last regeneration SKODA_DPF_FUEL_CONS_SINCE

  • Service 22DID 2088
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875
Unit
Raw value

In testing for 2001 to 2026.

Error counter bad fuel SKODA_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Fuel consumption SKODA_FUEL_CONS

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Fuel consumption - actual drive cycle SKODA_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Fuel consumption per driving cycle SKODA_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Fuel consumption since last DPF regeneration SKODA_FUEL_CONS_SINCE_DPF

  • Service 22DID 20D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

In testing for 2001 to 2026.

Fuel consumption, average SKODA_FUEL_AVG

  • Service 22DID 2299
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

Fuel filter: water level sensor 1 SKODA_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1

  • Service 22DID 197C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Fuel flow SKODA_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Fuel flow rate SKODA_PQ35_FUEL_FLOW

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2001 to 2026.

Fuel high pressure, actual value SKODA_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2001 to 2026.

Fuel high pressure, control deviation SKODA_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2001 to 2026.

Fuel high pressure, specified value SKODA_FUEL_HIGH_P_SPEC_7E0

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2001 to 2026.

Fuel high-pressure, specified value SKODA_FUEL_HIGH_P_SPEC

  • Service 22DID 116A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2001 to 2026.

Fuel injector time deviation, cylinder 1 SKODA_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Fuel injector time deviation, cylinder 2 SKODA_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Fuel injector time deviation, cylinder 2 SKODA_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Fuel injector time deviation, cylinder 3 SKODA_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Fuel injector time deviation, cylinder 4 SKODA_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2001 to 2026.

Fuel level SKODA_FLI

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

Fuel level SKODA_FLI_FC00

  • Service 22DID 14B4
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 L
Unit
L

In testing for 2001 to 2026.

Fuel level SKODA_FLI_V2

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2001 to 2026.

Fuel level SKODA_FUEL_LEVEL_7E0_2206

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2001 to 2026.

Fuel level SKODA_PQ35_FUEL_LEVEL_7E0_2206

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2001 to 2026.

Fuel level input SKODA_FLI_714

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 229A
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 L
Unit
L

In testing for 2001 to 2026.

Fuel level input SKODA_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel level input, v1 SKODA_FUEL_LEVEL_INPUT_V1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 327.67 L
Unit
L

In testing for 2001 to 2026.

Fuel level input, variant 2 SKODA_FLI_INPUT_VAR_2

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

Fuel level variant SKODA_FUEL_LVL_2

  • Service 22DID 100C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Fuel level, volume SKODA_FLI_VOL

  • Service 22DID 22B0
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

Fuel low pressure, actual value SKODA_FUEL_LOW_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2001 to 2026.

Fuel low pressure, actual value SKODA_FUEL_LOW_P_ACT_V2

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Fuel low pressure, specified value SKODA_FUEL_LOW_P_SPEC

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2001 to 2026.

Fuel low pressure, specified value SKODA_FUEL_LOW_P_SPEC_V2

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2001 to 2026.

Fuel mass request, integral controller SKODA_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2001 to 2026.

Fuel mass request, proportional controller SKODA_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2001 to 2026.

Fuel metering valve SKODA_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel mix correction coefficient SKODA_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2001 to 2026.

Fuel part from EVAP system SKODA_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2001 to 2026.

Fuel pressure regulator position SKODA_FUEL_P_REG

  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel pressure regulator valve specified rail pressure SKODA_FUEL_P_REG_SPEC

  • Service 22DID 121E
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2001 to 2026.

Fuel pressure, low actual SKODA_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2001 to 2026.

Fuel pump adaptation SKODA_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2001 to 2026.

Fuel pump specified value SKODA_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Fuel pump, commanded duty SKODA_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 2001 to 2026.

Fuel rate SKODA_FUEL_RATE

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L/h
Unit
L/h

In testing for 2001 to 2026.

Fuel rate SKODA_FUEL_RATE_V2

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2001 to 2026.

Fuel rate difference, injector/sensor SKODA_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2001 to 2026.

Fuel remaining SKODA_FLV

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 229A
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 255 L
Unit
L

In testing for 2001 to 2026.

Fuel tank fill level SKODA_FUEL_TANK_FILL_LEVEL

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

Fuel tank fill level SKODA_FUEL_TANK_FILL_LEVEL_V2

  • Service 22DID 24FC
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 2001 to 2026.

Fuel temperature SKODA_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Fuel temperature SKODA_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Fuel temperature SKODA_FUEL_T_7E0_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2001 to 2026.

High fuel pressure control deviation SKODA_HIGH_FUEL_P_CTRL_DEV

  • Service 22DID 121F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2001 to 2026.

High fuel pressure, actual SKODA_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2001 to 2026.

High fuel pressure, actual value SKODA_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2001 to 2026.

High fuel pressure, commanded SKODA_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2001 to 2026.

High fuel pressure, regulation error SKODA_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2001 to 2026.

High fuel pressure, target SKODA_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2001 to 2026.

High pressure fuel pressure actual SKODA_FUEL_P_HIGH

  • Service 22DID 1169
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2001 to 2026.

Instant fuel flow SKODA_INSTANT_FUEL_FLOW

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Long term fuel trim at idle SKODA_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 2001 to 2026.

Long term fuel trim at idle SKODA_LONG_TERM_FUEL_TRIM_IDLE_V2

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2001 to 2026.

Long term fuel trim bank 1 SKODA_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2001 to 2026.

Long term fuel trim direct injection at load SKODA_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2001 to 2026.

Long term fuel trim port injection at load SKODA_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2001 to 2026.

Low fuel pressure, actual SKODA_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2001 to 2026.

Low fuel pressure, commanded SKODA_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2001 to 2026.

Particle filter, fuel consumption since last regeneration SKODA_PARTICLE_FLT_FUEL

  • Service 22DID 115A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2001 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual SKODA_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2001 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum SKODA_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2001 to 2026.

Short term fuel trim bank 1 SKODA_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2001 to 2026.

GPS

Satellites, tracked SKODA_GPS_SATS_TRACKED

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Satellites, visible SKODA_GPS_SATS_VISIBLE

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Lights

Brake light SKODA_BRAKE_LIGHT_ON

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Brake light reading valid? SKODA_BRAKE_LIGHT_ON_VALID

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2001 to 2026.

Light assistance, number of reflectors SKODA_LIGHT_ASSISTANCE_NUM

  • Service 22DID 467C
  • Module74F → 7B9
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Light assistance, number of street lamps SKODA_LIGHT_ASSISTANCE_NUM_STREET_LAMPS

  • Service 22DID 467C
  • Module74F → 7B9
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Light assistance, status active SKODA_LIGHT_ASSISTANCE

  • Service 22DID 467C
  • Module74F → 7B9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Light assistance, total brightness SKODA_LIGHT_ASSISTANCE_TOT

  • Service 22DID 467C
  • Module74F → 7B9
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 2001 to 2026.

Movement

A/C compressor speed SKODA_CLIMATE_A_C_COMP_SPD

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2001 to 2026.

Acceleration SKODA_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCEL_7E0

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCEL_7E0_V2

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCEL_V2

  • Service 22DID 4539
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCELERATION

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration SKODA_ACCELERATION_29BIT_V2

  • Service 22DID 12B0
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Acceleration or deceleration mode SKODA_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Accelerator pedal limit SKODA_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Accelerator pedal position SKODA_ACCEL_PEDAL_POS

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position SKODA_ACCEL_PEDAL_POS_7E0

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position 1 SKODA_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal position 2 SKODA_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator pedal sensor 1 SKODA_ACCEL_PED_1

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Accelerator pedal sensor 2 SKODA_PQ35_ACCEL_PED_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2001 to 2026.

Accelerator pedal torque limit SKODA_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Accelerator pedal, sensor 2 SKODA_ACCEL_PEDAL_SENS_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2001 to 2026.

Accelerator position 1 SKODA_ACCEL_POS_1

  • Service 22DID F449
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Accelerator position 2 SKODA_ACCEL_POS_2

  • Service 22DID F44A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

All-wheel drive front-rear speed differential SKODA_PQ35_HAL_F_R_VSS_DIFF

  • Service 22DID 2BF0
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Aux. hydraulic pump RPM SKODA_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2001 to 2026.

Camshaft speed SKODA_CAM_SPD

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Camshaft speed SKODA_CAM_SPD_7E0

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2001 to 2026.

Camshaft speed SKODA_CAM_SPD_V2

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×310
Range
-9830 to 9830 %
Unit
%

In testing for 2001 to 2026.

Camshaft speed SKODA_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Camshaft speed SKODA_CAMSHAFT_VSS_V2

  • Service 22DID 1124
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Camshaft speed SKODA_PQ35_CAMS_SPD

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.3
Range
-9830.4 to 9830.1 rpm
Unit
rpm

In testing for 2001 to 2026.

Compressor speed SKODA_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Coupling sensor speed SKODA_CPL_SENS_SPD

  • Service 22DID 1801
  • Module70F → 779
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val2
Range
-1073741824 to 1073741823 rpm
Unit
rpm

In testing for 2001 to 2026.

Crankshaft speed SKODA_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Crankshaft speed SKODA_CRANKSHAFT_VSS_V2

  • Service 22DID 16F3
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Crankshaft speed, RPM SKODA_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2001 to 2026.

Diesel particulate filter exhaust speed SKODA_DPF_EXH_SPD

  • Service 22DID 44F9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34
Unit
Raw value

In testing for 2001 to 2026.

Drive shaft speed SKODA_DRIVE_SHFT_SPD_SENS

  • Service 22DID 5236
  • Module70F → 779
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val2
Range
-1073741824 to 1073741823 rpm
Unit
rpm

In testing for 2001 to 2026.

Electric drive motor angular speed SKODA_ELDRIVE_MOTOR_RAD_SEC

  • Service 22DID 40C8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000
Unit
Number

In testing for 2001 to 2026.

Engine RPM SKODA_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2001 to 2026.

Engine RPM SKODA_RPM_71D

  • Service 22DID F40C
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2001 to 2026.

Engine RPM at idle required SKODA_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Engine RPM at idle required SKODA_ENGINE_RPM_AT_IDLE_REQUIRED_V2

  • Service 22DID 1161
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Front left wheel speed SKODA_FL_VSS

  • Service 22DID 1800
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Front left wheel speed SKODA_FL_VSS_V2

  • Service 22DID 1800
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_PQ35_FL_VSS

  • Service 22DID 2B1B
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD_2

  • Service 22DID 2B1B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD_713

  • Service 22DID 2B1B
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD_7E1

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD_V2

  • Service 22DID 2B1B
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed SKODA_TIRE_FL_SPD_V3

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Front left wheel speed, raw count SKODA_FL_VSS_V2_RAW

  • Service 22DID 1800
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Front right wheel speed SKODA_FR_VSS

  • Service 22DID 1801
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Front right wheel speed SKODA_FR_VSS_V2

  • Service 22DID 1801
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_PQ35_FR_VSS

  • Service 22DID 2B1C
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD_2

  • Service 22DID 2B1C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD_713

  • Service 22DID 2B1C
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD_7E1

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD_V2

  • Service 22DID 2B1C
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed SKODA_TIRE_FR_SPD_V3

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right wheel speed, raw count SKODA_FR_VSS_V2_RAW

  • Service 22DID 1801
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Idle speed specified rpm SKODA_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2001 to 2026.

Injection speed injector 0 SKODA_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Injection speed injector 1 SKODA_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Injection speed injector 2 SKODA_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Injection speed injector 3 SKODA_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Input shaft speed SKODA_INPUT_SHAFT_VSS

  • Service 22DID 2102
  • ModuleFC00 → FE0077
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Input shaft speed 1 SKODA_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 32766 rpm
Unit
rpm

In testing for 2001 to 2026.

Input shaft speed 2 SKODA_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 32766 rpm
Unit
rpm

In testing for 2001 to 2026.

Lateral acceleration SKODA_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Limitation, accelerator pedal SKODA_LIM_ACCEL_PEDAL

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Longitudinal acceleration SKODA_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Longitudinal acceleration, raw SKODA_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Longitudinal acceleration, raw SKODA_LONGTITUDINAL_ACCELERATION_RAW_VALUE_V2

  • Service 22DID 15CF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

Misfires per 1000 rpm, all cylinders SKODA_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 1 SKODA_MIS_PER_1000_RPM_1

  • Service 22DID 1484
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 2 SKODA_MIS_PER_1000_RPM_2

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 3 SKODA_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 4 SKODA_MIS_PER_1000_RPM_4

  • Service 22DID 1485
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 5 SKODA_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires per 1000 rpm:, cylinder 6 SKODA_MIS_PER_1000_RPM_6

  • Service 22DID 1487
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 1 SKODA_MISFIRES_1000_RPM_C1

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 1 SKODA_MISFIRES_1000_RPM_C1_V2

  • Service 22DID 291D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 2 SKODA_MISFIRES_1000_RPM_C2

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 2 SKODA_MISFIRES_1000_RPM_C2_V2

  • Service 22DID 2920
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 3 SKODA_MISFIRES_1000_RPM_C3

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 3 SKODA_MISFIRES_1000_RPM_C3_V2

  • Service 22DID 291E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 4 SKODA_MISFIRES_1000_RPM_C4

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Misfires/1000 rpm, cylinder 4 SKODA_MISFIRES_1000_RPM_C4_V2

  • Service 22DID 291F
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Mixture adaptation factor at idle speed SKODA_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2001 to 2026.

Motor RPM SKODA_ELDRIVE_MOTOR_RPM

  • Service 22DID F40C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Output shaft speed SKODA_OUTPUT_SHAFT_VSS

  • Service 22DID 2103
  • ModuleFC00 → FE0077
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Particle sensor, exhaust speed SKODA_PARTICLE_SENS_EXH

  • Service 22DID 44F9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655
Unit
Raw value

In testing for 2001 to 2026.

Rear left wheel speed SKODA_PQ35_RL_VSS

  • Service 22DID 2B1D
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_RL_VSS

  • Service 22DID 1802
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Rear left wheel speed SKODA_RL_VSS_V2

  • Service 22DID 1802
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD_2

  • Service 22DID 2B1D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD_713

  • Service 22DID 2B1D
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD_7E1

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD_V2

  • Service 22DID 2B1D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed SKODA_TIRE_RL_SPD_V3

  • Service 22DID 2B1D
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left wheel speed, raw count SKODA_RL_VSS_V2_RAW

  • Service 22DID 1802
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Rear right wheel speed SKODA_PQ35_RR_VSS

  • Service 22DID 2B1E
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_RR_VSS

  • Service 22DID 1803
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Rear right wheel speed SKODA_RR_VSS_V2

  • Service 22DID 1803
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD_2

  • Service 22DID 2B1E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD_713

  • Service 22DID 2B1E
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD_7E1

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD_V2

  • Service 22DID 2B1E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed SKODA_TIRE_RR_SPD_V3

  • Service 22DID 2B1E
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 1000 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right wheel speed, raw count SKODA_RR_VSS_V2_RAW

  • Service 22DID 1803
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Reducing agent pump, differential speed calculated SKODA_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2001 to 2026.

Specified idle RPM SKODA_MQB_DQ250_SPECIFIED_IDLE_RPM

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2001 to 2026.

Speed ​​output SKODA_DQ250_SPD_OUTPUT

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission input shaft speed SKODA_PQ35_TRANS_IN_SPD

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission input shaft speed SKODA_TRANS_IN_SPD

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 10000 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission input speed SKODA_MQB_TCM_TRANSMISSION_INPUT_SPD

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission input speed SKODA_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission output speed SKODA_MQB_TCM_TRANSMISSION_OUTPUT_SPD

  • Service 22DID 2103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission output speed SKODA_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission read 1001, first byte raw count SKODA_TCM_1001_RAW

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Vehicle lateral acceleration, raw value SKODA_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2001 to 2026.

Vehicle lateral acceleration, raw value SKODA_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE_V2

  • Service 22DID 15D1
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2001 to 2026.

Vehicle speed SKODA_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed SKODA_VSS_71D

Pelican can show this parameter as the speed.

  • Service 22DID 2B16
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed SKODA_VSS_7E1

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed SKODA_VSS_V2

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed ESP SKODA_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed from transmission SKODA_E_TRON_TRON_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed from transmission SKODA_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed from transmission, raw count SKODA_VSS_TCM_RAW

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Vehicle speed, directional SKODA_VSS_DIR

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 km/h
Unit
km/h

In testing for 2001 to 2026.

Vehicle speed, HR SKODA_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2001 to 2026.

Yaw acceleration, raw value SKODA_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2001 to 2026.

SKODA_PQ35_TIME_LAST

Time since last regeneration SKODA_PQ35_TIME_LAST_REGEN

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10066666667
Range
0 to 0.426 min
Unit
min

In testing for 2001 to 2026.

Stats

Crashes, driver side SKODA_CRASH_CNT_DRVR

  • Service 22DID 2354
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Crashes, driver side SKODA_CRASH_DRVR

  • Service 22DID 2354
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Crashes, front SKODA_CRASH_CNT_FRONT

  • Service 22DID 2353
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Crashes, front SKODA_CRASH_FRONT

  • Service 22DID 2353
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Crashes, passenger side SKODA_CRASH_CNT_PSNGR

  • Service 22DID 2355
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Crashes, passenger side SKODA_CRASH_PASS

  • Service 22DID 2355
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Crashes, rear SKODA_CRASH_CNT_REAR

  • Service 22DID 2356
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Crashes, rear SKODA_CRASH_REAR

  • Service 22DID 2356
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Crashes, rollover SKODA_CRASH_CNT_ROLL

  • Service 22DID 2357
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Driving time in economy mode SKODA_DRIVE_TIME_ECO

Value may be wrong, needs more validation. Proportion of time spent driving in eco mode

  • Service 22DID 0303
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driving time, manual SKODA_DRIVE_TIME_MANUAL

Value may be wrong, needs more validation. Proportion of time spent driving in manual mode

  • Service 22DID 0305
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driving time, sport SKODA_DRIVE_TIME_SPORT

Value may be wrong, needs more validation. Proportion of time spent driving in sport mode

  • Service 22DID 0304
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Launch control count SKODA_LAUNCH

How many times you've initiated launch control on the car.

  • Service 22DID 5200
  • Module7E5
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000000
Unit
Number

In testing for 2001 to 2026.

Rollovers SKODA_ROLLOVER

  • Service 22DID 2357
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Total drive time SKODA_DRIVE_TIME

  • Service 22DID 0302
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 h
Unit
h

In testing for 2001 to 2026.

Tires

All-wheel drive friction disc temperature SKODA_PQ35_HAL_FRICT_T

  • Service 22DID 2BE4
  • Module70F → 779
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val100−227.67
Range
-227.67 to 427.68 °C
Unit
°C

In testing for 2001 to 2026.

Entire energy throughput SKODA_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 2001 to 2026.

Front left tire current pressure SKODA_TP_FL_V2

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front left tire pressure SKODA_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Front left tire pressure, set point SKODA_TP_SET_FL

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Front left tire sensor id SKODA_TID_FL

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Front left tire specified pressure SKODA_TPS_FL

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front left tire temperature SKODA_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Front left tire temperature SKODA_TT_FL_V2

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Front left tire warning pressure SKODA_TPW_FL

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front left wheel speed SKODA_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2001 to 2026.

Front right tire current pressure SKODA_TP_FR_V2

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front right tire pressure SKODA_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Front right tire pressure, set point SKODA_TP_SET_FR

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Front right tire sensor id SKODA_TID_FR

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Front right tire specified pressure SKODA_TPS_FR

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front right tire temperature SKODA_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Front right tire temperature SKODA_TT_FR_V2

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Front right tire warning pressure SKODA_TPW_FR

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Front right wheel speed SKODA_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear left tire current pressure SKODA_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear left tire pressure SKODA_TP_RL_V2

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Rear left tire pressure, set point SKODA_TP_SET_RL

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Rear left tire sensor id SKODA_TID_RL

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Rear left tire specified pressure SKODA_TPS_RL

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear left tire temperature SKODA_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Rear left tire temperature SKODA_TT_RL_V2

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Rear left tire warning pressure SKODA_TPW_RL

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear left wheel speed SKODA_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2001 to 2026.

Rear right flat tire indicator SKODA_TPMS_RR_R_FLAT_TIRE_IND

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Rear right tire current pressure SKODA_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear right tire pressure SKODA_TP_RR_V2

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Rear right tire pressure, set point SKODA_TP_SET_RR

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 bar
Unit
bar

In testing for 2001 to 2026.

Rear right tire sensor id SKODA_TID_RR

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2026.

Rear right tire specified pressure SKODA_TPS_RR

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear right tire temperature SKODA_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Rear right tire temperature SKODA_TT_RR_V2

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Rear right tire warning pressure SKODA_TPW_RR

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Rear right wheel speed SKODA_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2001 to 2026.

Steering wheel angle SKODA_MQB_SWA

  • Service 22DID 1812
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8+0.06
Range
-4095.94 to 4095.935 °
Unit
°

In testing for 2001 to 2026.

Steering wheel angle SKODA_MQB_SWA_ALT

  • Service 22DID 1804
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.562 °
Unit
°

In testing for 2001 to 2026.

Steering wheel angle SKODA_STEER_ANGLE_EPS

  • Service 22DID 1812
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 °
Unit
°

In testing for 2001 to 2026.

Steering wheel angle SKODA_STEER_WHEEL_ANGLE

  • Service 22DID 1812
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−750
Range
-750 to 780 °
Unit
°

In testing for 2001 to 2026.

Steering wheel angle SKODA_STEER_WHL_ANG

  • Service 22DID 2B29
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-110+819.2
Range
-5734 to 819 °
Unit
°

In testing for 2001 to 2026.

Steering wheel angle SKODA_SWA_ALT

  • Service 22DID 1804
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.5625 °
Unit
°

In testing for 2001 to 2026.

Steering wheel temperature SKODA_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2001 to 2026.

Steering wheel torque sensor 1 SKODA_STEER_TQ_1

  • Service 22DID 1805
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2001 to 2026.

Steering wheel torque sensor 1 SKODA_STEER_WHL_TQ_SENS_1

  • Service 22DID 1805
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143 to 144 °
Unit
°

In testing for 2001 to 2026.

Steering wheel torque sensor 2 SKODA_STEER_TQ_2

  • Service 22DID 1806
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2001 to 2026.

Steering wheel torque sensor 2 SKODA_STEER_WHL_TQ_SENS_2

  • Service 22DID 1806
  • Module712 → 77C
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143 to 144 °
Unit
°

In testing for 2001 to 2026.

Tire #2 pressure SKODA_TP_2

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 1 current pressure SKODA_TP_1

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 1 position SKODA_TPOS_RL

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0FLFront left
1FRFront right
2RLRear left
3RRRear right

In testing for 2001 to 2026.

Tire 1 sensor id SKODA_TID_1

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Tire 1 specified pressure SKODA_TPS_1

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 1 temperature SKODA_TT_1

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 18A0
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Tire 2 position SKODA_TPOS_FR

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0FLFront left
1FRFront right
2RLRear left
3RRRear right

In testing for 2001 to 2026.

Tire 2 sensor id SKODA_TID_2

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Tire 2 specified pressure SKODA_TPS_2

  • Service 22DID 18A1
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 3 current pressure SKODA_TP_3

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 3 position SKODA_TPOS_RR

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0FLFront left
1FRFront right
2RLRear left
3RRRear right

In testing for 2001 to 2026.

Tire 3 sensor id SKODA_TID_3

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Tire 3 specified pressure SKODA_TPS_3

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 3 temperature SKODA_TT_3

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 18A2
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Tire 4 current pressure SKODA_TP_4

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 4 position SKODA_TPOS_FL

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0FLFront left
1FRFront right
2RLRear left
3RRRear right

In testing for 2001 to 2026.

Tire 4 sensor id SKODA_TID_4

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Tire 4 specified pressure SKODA_TPS_4

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2001 to 2026.

Tire 4 temperature SKODA_TT_4

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 18A3
  • Module70B → 775
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

In testing for 2001 to 2026.

Tire pressure monitoring available SKODA_TPMS_AVAIL

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Tire pressure monitoring front left flat tire indicator SKODA_TPMS_FL_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring front left tire leakage rate SKODA_TPMS_FL_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring front right flat tire indicator SKODA_TPMS_FR_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring front right tire leakage rate SKODA_TPMS_FR_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading at fourth to last warning SKODA_TPMS_ODO_WARN_4

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading at last adaptation SKODA_TPMS_ODO_ADAPT_1

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading at last warning SKODA_TPMS_ODO_WARN_1

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading at second to last warning SKODA_TPMS_ODO_WARN_2

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading at third to last warning SKODA_TPMS_ODO_WARN_3

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading four adaptations ago SKODA_TPMS_ODO_ADAPT_4

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading three adaptations ago SKODA_TPMS_ODO_ADAPT_3

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring odometer reading two adaptations ago SKODA_TPMS_ODO_ADAPT_2

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Tire pressure monitoring rear left flat tire indicator SKODA_TPMS_RL_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring rear left tire leakage rate SKODA_TPMS_RL_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring rear right flat tire indicator SKODA_TPMS_RR_FLAT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring rear right tire leakage rate SKODA_TPMS_RR_TIRE_LEAK

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Tire pressure monitoring system available SKODA_TPMS

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2001 to 2026.

Transmission

Actual position clutch 1 duty cycle factor 1 SKODA_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1

  • Service 22DID 3832
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Actual position clutch 1 duty cycle factor 2 SKODA_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2

  • Service 22DID 3833
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Actual position clutch 2 duty cycle factor 1 SKODA_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1

  • Service 22DID 383B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Actual position clutch 2 duty cycle factor 2 SKODA_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2

  • Service 22DID 383C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Actual position of gear positioner a SKODA_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Actual position of gear positioner b SKODA_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Actual position of gear positioner c SKODA_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Actual position of gear positioner d SKODA_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Adaptation counter PF lockup clutch SKODA_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, clutch a SKODA_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, clutch b SKODA_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, clutch c SKODA_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, clutch d SKODA_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, clutch e SKODA_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, fast fill time, clutch a SKODA_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, fast fill time, clutch b SKODA_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, fast fill time, clutch c SKODA_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, fast fill time, clutch d SKODA_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation counter, fast fill time, clutch e SKODA_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Adaptation inflation current PF lockup clutch SKODA_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2001 to 2026.

All-wheel drive clutch blockage degree SKODA_MQB_HAL_CLUTCH_BLOCK

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val×8
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

All-wheel drive clutch fully open SKODA_MQB_HAL_CLUTCH_OPEN

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Clutch 0 commanded pressure offset SKODA_MQB_DL382_CLUTCH_0_CMD_P_OFFSET

  • Service 22DID 1426
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 0, commanded pressure offset SKODA_CLU_0_CMD_P_OFFSET

  • Service 22DID 1426
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 absolute pressure SKODA_CLU_1_ABS_P

  • Service 22DID 13CC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 actual pressure SKODA_PQ35_CLUTCH_1_ACTUAL_P

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 actual pressure raw value SKODA_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment SKODA_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 0 position SKODA_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 1 moment SKODA_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 1 position SKODA_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 2 moment SKODA_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 2 position SKODA_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 3 moment SKODA_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristic point 3 position SKODA_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristics point 0 position SKODA_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristics point 1 position SKODA_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38AF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristics point 2 position SKODA_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 7000
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 adaptation basic characteristics point 3 position SKODA_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 7001
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 adaptation clutch end position closed SKODA_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38FF
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 adaptation clutch end position open SKODA_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38FE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 characteristic curve shift SKODA_CLUTCH_1_CHAR_CURVE_SHIFT

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 characteristic curve shift SKODA_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.11 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 1 commanded pressure SKODA_PQ35_CLUTCH_1_CMD_P

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 failed adaptations counter SKODA_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 1 friction value correction factor SKODA_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Clutch 1 lower adaptation point SKODA_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 nominal pressure SKODA_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 pressure SKODA_CLU_1_P

  • Service 22DID 214C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 protection function engaged quantity SKODA_PQ35_CLUTCH_1_PROT_ENGAGED_QTY

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Clutch 1 successful adaptations counter SKODA_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 1 upper adaptation point SKODA_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 1 valve current: actual SKODA_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2001 to 2026.

Clutch 1 valve current: specified SKODA_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2001 to 2026.

Clutch 2 absolute pressure SKODA_CLU_2_ABS_P

  • Service 22DID 13CD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 actual pressure SKODA_PQ35_CLUTCH_2_ACTUAL_P

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 actual pressure raw value SKODA_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUE

  • Service 22DID 10FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 actual torque SKODA_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 0 moment SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 0 position SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 1 moment SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 1 position SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 2 moment SKODA_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 2 position SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 3 moment SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristic point 3 position SKODA_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristics point 0 position SKODA_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38FA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristics point 1 position SKODA_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38FB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristics point 2 position SKODA_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 38FC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation basic characteristics point 3 position SKODA_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 38FD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation clutch end position closed SKODA_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38AB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation clutch end position open SKODA_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38AA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 adaptation end position closed SKODA_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 adaptation end position opened SKODA_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 characteristic curve shift SKODA_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.111 mm
Unit
mm

In testing for 2001 to 2026.

Clutch 2 commanded pressure SKODA_PQ35_CLUTCH_2_CMD_P

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 failed adaptations counter SKODA_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 2 friction value correction factor SKODA_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Clutch 2 lower adaptation point SKODA_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 pressure SKODA_CLU_2_P

  • Service 22DID 214D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 protection function engaged quantity SKODA_PQ35_CLUTCH_2_PROT_ENGAGED_QTY

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2001 to 2026.

Clutch 2 successful adaptations counter SKODA_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Clutch 2 upper adaptation point SKODA_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Clutch 2 valve current: actual SKODA_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2001 to 2026.

Clutch 2 valve current: specified SKODA_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2001 to 2026.

Clutch adaptation values initial kill point 0 for K1 SKODA_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Clutch adaptation values initial kill point 0 for K2 SKODA_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Clutch adaptation values lower current point adaptation K1 SKODA_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Clutch adaptation values lower current point adaptation K2 SKODA_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Clutch kiss point rapid adaptation remaining SKODA_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Clutch overheating, clutch SKODA_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Clutch temperature SKODA_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Clutch temperature calculated SKODA_CLU_T_CALC

  • Service 22DID 18E3
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Clutch_0 temperature calculated SKODA_CLU_0_T_CALC

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Correction values for main press adaptation: high press on clutch 1 SKODA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Correction values for main press adaptation: low press on clutch 1 SKODA_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 SKODA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 SKODA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2001 to 2026.

Coupling clutch torque SKODA_CPL_CLU_TQ

  • Service 22DID 13ED
  • Module70F → 779
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2001 to 2026.

Current gear SKODA_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2001 to 2026.

Current gear SKODA_GEAR

The automatic transmission gear.

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear

In testing for 2001 to 2026.

Current gear SKODA_MQB_TCM_I_GEAR

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2001 to 2026.

Current gear SKODA_MQB_TCM_I_GEAR_DQ200

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2001 to 2026.

Current gear SKODA_PQ35_GEAR

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2001 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation SKODA_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation SKODA_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Current N371 pressure control valve 6 lock-up clutch SKODA_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2001 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation SKODA_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation SKODA_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2001 to 2026.

Driving strategy mountain factor SKODA_DRIVING_STRATEGY_MOUNTAIN_FACTOR

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driving strategy sport factor SKODA_DRIVING_STRATEGY_SPORT_FACTOR

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Dynamic shift program SKODA_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for oxygen shift, cylinder 1 SKODA_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for oxygen shift, cylinder 2 SKODA_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for oxygen shift, cylinder 3 SKODA_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Early ignition counter for oxygen shift, cylinder 4 SKODA_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Engaged position side a gear selector 1-3 SKODA_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side a gear selector 2-4 SKODA_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side a gear selector 5 and neutral SKODA_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side a gear selector 6 and reverse SKODA_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side b gear selector 1-3 SKODA_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side b gear selector 2-4 SKODA_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side b gear selector 5 and neutral SKODA_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engaged position side b gear selector 6 and reverse SKODA_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Engine specified torque during transmission intervention SKODA_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2001 to 2026.

Fast fill time, clutch a SKODA_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2001 to 2026.

Fast fill time, clutch b SKODA_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2001 to 2026.

Fast fill time, clutch c SKODA_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2001 to 2026.

Fast fill time, clutch d SKODA_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2001 to 2026.

Fast fill time, clutch e SKODA_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2001 to 2026.

Fill pressure, clutch a SKODA_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2001 to 2026.

Fill pressure, clutch b SKODA_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2001 to 2026.

Fill pressure, clutch c SKODA_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2001 to 2026.

Fill pressure, clutch d SKODA_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2001 to 2026.

Fill pressure, clutch e SKODA_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2001 to 2026.

Gear SKODA_GEAR_V2

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G1 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G2 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G3 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G4 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G5 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G6 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position G7 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation engaged position GR SKODA_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G1 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G2 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G3 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G4 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G5 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G6 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position G7 SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear actuator adaptation synchronization position reverse SKODA_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear engaged SKODA_GEAR_ENGAGED

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Gear selector a adaptation neutral position SKODA_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear selector b adaptation neutral position SKODA_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear selector c adaptation neutral position SKODA_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear selector d adaptation neutral position SKODA_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2001 to 2026.

Gear selector synchronous position G1 SKODA_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position G2 SKODA_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position G3 SKODA_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position G4 SKODA_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position G5 SKODA_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position G6 SKODA_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Gear selector synchronous position, reverse SKODA_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2001 to 2026.

Input shaft 1 SKODA_MQB_INPUT_SHAFT_1

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Input shaft 2 SKODA_MQB_INPUT_SHAFT_2

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Launch control counter, clutch 1 SKODA_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Load shift flaps, actual value SKODA_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Load shift flaps, specified value SKODA_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation SKODA_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2001 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation SKODA_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2001 to 2026.

Mileage of oxidation catalytic converter SKODA_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Mileage of SCR catalytic converter SKODA_MILEAGE_SCR

  • Service 22DID 519E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Neutral position gear selector 1-3 SKODA_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Neutral position gear selector 2-4 SKODA_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Neutral position gear selector 5 and neutral SKODA_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Neutral position gear selector 6 and reverse SKODA_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Nominal pressure clutch 2 SKODA_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2001 to 2026.

Output shaft 1 SKODA_MQB_OUTPUT_SHAFT_1

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Output shaft 2 SKODA_MQB_OUTPUT_SHAFT_2

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Powertrain overall gear ratio SKODA_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2001 to 2026.

Pressure_clutch_1 SKODA_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Pressure_clutch_2 SKODA_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Road resistance SKODA_PQ35_ROAD_RESISTANCE

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.895 %
Unit
%

In testing for 2001 to 2026.

Road resistance SKODA_ROAD_RESISTANCE

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

In testing for 2001 to 2026.

Selected gear SKODA_SELECTED_GEAR

  • Service 22DID 15AA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Selected gear SKODA_SELECTED_GEAR_7E1

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2001 to 2026.

Selected gear SKODA_SELECTED_GEAR_V2

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

In testing for 2001 to 2026.

Selected gear SKODA_SELECTED_GEAR_V3

  • Service 22DID 7050
  • ModuleFC00 → FE0077
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2001 to 2026.

Shift gear SKODA_GEAR_SHFT

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1REVERSEReverse
2PARKPark
3DRIVEDrive

In testing for 2001 to 2026.

Shift in progress, selected gear SKODA_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Shift in progress, target gear SKODA_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Specified torque clutch 1 SKODA_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Specified torque clutch 1 - data SKODA_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2001 to 2026.

Specified torque clutch 2 SKODA_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

In testing for 2001 to 2026.

Specified torque clutch 2 - data SKODA_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2001 to 2026.

Status clutch torque, target torque SKODA_STAT_CLU_TQ_SOLL_TQ

  • Service 22DID 110A
  • Module70F → 779
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 N·m
Unit
N·m

In testing for 2001 to 2026.

Stiffness point pressure clutch 1 SKODA_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1

  • Service 22DID 1419
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2001 to 2026.

Stiffness point pressure clutch 1 SKODA_STIFFNESS_POINT_P_1

  • Service 22DID 1419
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Stiffness point pressure clutch 2 SKODA_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2

  • Service 22DID 141A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2001 to 2026.

Stiffness point pressure clutch 2 SKODA_STIFFNESS_POINT_P_2

  • Service 22DID 141A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2001 to 2026.

Synchronous position side a gear selector 1-3 SKODA_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side a gear selector 2-4 SKODA_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side a gear selector 5 and neutral SKODA_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side a gear selector 6 and reverse SKODA_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side b gear selector 1-3 SKODA_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side b gear selector 2-4 SKODA_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side b gear selector 5 and neutral SKODA_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Synchronous position side b gear selector 6 and reverse SKODA_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2001 to 2026.

Thermal load of left clutch SKODA_THERMAL_LOAD_LEFT

  • Service 22DID 2B07
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2001 to 2026.

Thermal load of right clutch SKODA_THERMAL_LOAD_RIGHT

  • Service 22DID 2B08
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2001 to 2026.

Time since shift SKODA_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2001 to 2026.

Torque converter amplification SKODA_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2001 to 2026.

Torque converter lockup clutch adaptation count SKODA_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Torque converter lockup clutch fill time adaptation SKODA_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2001 to 2026.

Torque converter lockup clutch status SKODA_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS

  • Service 22DID 7078
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Torque loss adaptation, A/C compressor + gear engaged SKODA_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation, A/C compressor + gear engaged SKODA_TQ_LOSS_ADPT_AC_COMP_GEAR

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2001 to 2026.

Torque loss adaptation, gear engaged SKODA_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2001 to 2026.

Transmission coolant valve, open SKODA_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Transmission drag torque SKODA_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Transmission fluid temperature 2 SKODA_ATF_T_2

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2001 to 2026.

Transmission gear ratio SKODA_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2001 to 2026.

Transmission input speed - shaft 1 SKODA_TRANS_INPUT_SPD_SHFT_1

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission input speed - shaft 2 SKODA_TRANS_INPUT_SPD_SHFT_2

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2001 to 2026.

Transmission part 1 pressure actual SKODA_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2001 to 2026.

Transmission part 1 pressure commanded SKODA_MQB_TCM_TRANSMISSION_PART_1_P_CMD

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2001 to 2026.

Transmission part 1 valve current actual SKODA_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2001 to 2026.

Transmission part 1 valve current commanded SKODA_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2001 to 2026.

Transmission part 2 pressure actual SKODA_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2001 to 2026.

Transmission part 2 pressure commanded SKODA_MQB_TCM_TRANSMISSION_PART_2_P_CMD

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2001 to 2026.

Transmission part 2 valve current actual SKODA_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2001 to 2026.

Transmission part 2 valve current commanded SKODA_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2001 to 2026.

Transmission torque losses SKODA_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2001 to 2026.

Transmission value 1004, raw SKODA_TCM_1004_RAW

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Upper adapted coupling point clutch 1 from microslip adaptation SKODA_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2001 to 2026.

Upper adapted coupling point clutch 2 from microslip adaptation SKODA_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2001 to 2026.

Working hours SKODA_PQ35_WORKING_HOURS

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.92942
Unit
Raw value

In testing for 2001 to 2026.

Working hours SKODA_WORKING_HOURS

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

In testing for 2001 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 SKODA_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 1 temperature time in range 2 SKODA_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 1 temperature time in range 3 SKODA_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 2 temperature time in range 0 SKODA_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 2 temperature time in range 1 SKODA_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 2 temperature time in range 2 SKODA_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Analysis, clutch 2 temperature time in range 3 SKODA_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Average consumption, category 0 SKODA_AVG_CSMP_CAT0

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 1 SKODA_AVG_CSMP_CAT1

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 2 SKODA_AVG_CSMP_CAT2

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 3 SKODA_AVG_CSMP_CAT3

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 4 SKODA_AVG_CSMP_CAT4

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 5 SKODA_AVG_CSMP_CAT5

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Average consumption, category 6 SKODA_AVG_CSMP_CAT6

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2001 to 2026.

Clutch 1 adaptation kiss point part 1 odometer reading SKODA_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Clutch 1 temperature time in range 0 SKODA_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2001 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading SKODA_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Counter steer support, odometer, last activated SKODA_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACT

  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Diesel particulate filter distance since last regeneration SKODA_DPF_DIST_SINCE_REGEN

  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Diesel particulate filter distance since last regeneration, bank 1 SKODA_DPF_DIST_SINCE_REGEN_1

  • Service 22DID 14B8
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Diesel particulate filter distance since last regeneration, bank 2 SKODA_DPF_DIST_SINCE_REGEN_2

  • Service 22DID 1460
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Distance since last regeneration SKODA_DIST_SINCE_REGEN

  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2001 to 2026.

Distance to detected pedestrian SKODA_DIST_DETECTED

  • Service 22DID F41B
  • Module74F → 7B9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 m
Unit
m

In testing for 2001 to 2026.

Distance to empty SKODA_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Drive cycles counter SKODA_MQB_TCM_DRIVE_CYCLES_COUNTER

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Driving time ecological SKODA_MQB_TCM_DRIVING_TIME_ECOLOGICAL

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driving time manual SKODA_MQB_TCM_DRIVING_TIME_MANUAL

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Driving time sporty SKODA_MQB_TCM_DRIVING_TIME_SPORTY

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine control unit distance driven SKODA_ECU_DIST_DRIVEN

  • Service 22DID 1160
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Ignition cycles SKODA_MQB_TCM_IGNITION_CYCLES

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2026.

Mixture variation in adapted part load range 1 SKODA_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Odometer SKODA_ENG_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_MQB_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777175 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_MQB_TCM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_3

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_3_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 255 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4000000000 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_7E0_2

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_7E0_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_7E1

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_ECM

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 1048575 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_V1

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val−40
Range
-40 to 16777175 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_ODO_V3

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer SKODA_PQ35_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Odometer (TCM #1) SKODA_ODO_TCM_1

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer (TCM #2) SKODA_ODO_TCM_2

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer #2 SKODA_MQB_TCM_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2001 to 2026.

Odometer #3 SKODA_PQ35_ODO_3

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer at oxidation catalytic converter replacement SKODA_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer at SCR catalytic converter replacement SKODA_ODO_SCR_CATALYTIC

  • Service 22DID 4F41
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at DPF replace SKODA_ODO_READING_DPF

  • Service 22DID 25FE
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at fourth-to-last warning SKODA_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 240 to 271 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at last adaptation SKODA_TPMS_ODO_RDG_AT_LAST_ADAPT

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 16 to 47 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at last warning SKODA_TPMS_ODO_RDG_AT_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 144 to 175 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at next-to-last warning SKODA_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 176 to 207 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading at third-to-last warning SKODA_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARN

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 208 to 239 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading four adaptations ago SKODA_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 112 to 143 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading three adaptations ago SKODA_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading two adaptations ago SKODA_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGO

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 48 to 79 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer reading when changing DPF SKODA_ODO_READING_CHANGING

  • Service 22DID 4F40
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer with ECU installed SKODA_ODO_ECU_INSTALLED

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2001 to 2026.

Odometer, alternate SKODA_PQ35_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer, alternative SKODA_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer, alternative SKODA_ODO_2_2

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer, battery management system SKODA_BMS_ODO

  • Service 22DID 02BD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer, battery management system, second read SKODA_ODO_BMS2

Pelican can show this parameter as the odometer.

  • Service 22DID 5867
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2001 to 2026.

Odometer, dash SKODA_ODO_DASH

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 255 km
Unit
km

In testing for 2001 to 2026.

Odometer, electric drive SKODA_ODO_V4

Pelican can show this parameter as the odometer.

  • Service 22DID 086D
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer, high resolution SKODA_ODO_HD

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage SKODA_ODO_MILEAGE

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage SKODA_ODO_MILEAGE_V2

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage 1 SKODA_ODO_MILEAGE_1

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage 2 SKODA_ODO_MILEAGE_2

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage, HR SKODA_E_TRON_TRON_ODO_MILEAGE_HR

Pelican can show this parameter as the odometer.

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Odometer, mileage, HR SKODA_ODO_MILEAGE_HR

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2001 to 2026.

Operating time, temperature range 1 SKODA_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Operating time, temperature range 2 SKODA_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Operating time, temperature range 3 SKODA_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Operating time, temperature range 4 SKODA_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Operating time, temperature range 5 SKODA_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Operating time, temperature range 6 SKODA_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2001 to 2026.

Range remaining SKODA_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

In testing for 2001 to 2026.

Range remaining, displayed SKODA_RANGE_DSP

Pelican can show this parameter as the electric range.

  • Service 22DID 22E0
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2001 to 2026.

Range remaining, unit unconfirmed SKODA_RANGE_V2

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

In testing for 2001 to 2026.

Remaining distance until reducing agent deficiency SKODA_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 2001 to 2026.

Torque converter time in temperature range 1 SKODA_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 2 SKODA_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 3 SKODA_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 4 SKODA_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 5 SKODA_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 6 SKODA_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 7 SKODA_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Torque converter time in temperature range 8 SKODA_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2001 to 2026.

Trip consumption, short SKODA_TRIP_USE_SHORT

  • Service 22DID 0530
  • Module714 → 77E
  • Every500 ms
  • Testing

Bits 238 to 255 of the reply, 18 bits. The value is signed.

Formula
val1000
Range
-131 to 131 kWh/100 mi
Unit
kWh/100 mi

In testing for 2001 to 2026.

Vehicle distance driven SKODA_VEHICLE_DIST_DRIVEN

  • Service 22DID 10E0
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2001 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.