Toyota Fortuner

Parameters

The Toyota Fortuner has 510 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage FORTUNER_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 15 V
Unit
V

0x2B84 = 11140 → 11140×12.20710000 = 13.598598 V

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage FORTUNER_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2005 to 2026.

1st turbocharger outlet pressure, control valve FORTUNER_1ST_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

2nd turbocharger outlet pressure FORTUNER_2ND_TRUBOCHARGER_OUTLET_P

  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

2nd turbocharger outlet pressure, control valve FORTUNER_2ND_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

AFS voltage B1S1 FORTUNER_AFS_VOLTAGE_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Aux. battery capacity after IG OFF FORTUNER_AUX_BAT_CAP_AFTER_IG_OFF

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2005 to 2026.

Aux. battery capacity after IG ON FORTUNER_AUX_BAT_CAP_AFTER_IG_ON

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2005 to 2026.

Battery current FORTUNER_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2005 to 2026.

Battery current FORTUNER_BAT_CURRENT_700

  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4912850−125
Range
-125 to 124.9 A
Unit
A

In testing for 2005 to 2026.

Battery status of full charge FORTUNER_BAT_STAT_FULL_CHG

  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2552
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2005 to 2026.

Battery temperature FORTUNER_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2005 to 2026.

Battery temperature FORTUNER_BAT_T_700

  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2026.

Battery temperature FORTUNER_BAT_T_700_2

  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2005 to 2026.

Battery voltage FORTUNER_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 15 V
Unit
V

0x2B84 = 11140 → 11140×12.20710000 = 13.598598 V

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Battery voltage FORTUNER_BAT_VConfirmed

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x87 = 135 → 13510 = 13.5 V

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Battery voltage FORTUNER_BATTERY_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Charge contactor current FORTUNER_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Charging integrated current of aux. battery FORTUNER_CHG_INTEGRATED

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2005 to 2026.

Dark current of battery FORTUNER_DARK_CURRENT_BAT

  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2005 to 2026.

Discharging integrated current of aux. battery FORTUNER_DISCHARGING

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2005 to 2026.

Distance since last battery cable disconnection FORTUNER_12V_DISCONNECT_ODOConfirmed

  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x2F35 = 12085 → 12,085 km

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Initial engine battery voltage lower limit FORTUNER_INITIAL_ENG_BAT_V_LO

  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2005 to 2026.

Main connector solenoid current FORTUNER_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Main relay a, solenoid current FORTUNER_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Main relay r solenoid current FORTUNER_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Output speed sensor voltage FORTUNER_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2005 to 2026.

Regenerative braking cooperation FORTUNER_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Regenerative operation FORTUNER_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Regenerative request FORTUNER_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Relay control solenoid current FORTUNER_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Service contactor solenoid current FORTUNER_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Sleep time of battery sensor FORTUNER_SLEEP_TIME_BATSENS

  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2005 to 2026.

Turbine speed sensor voltage FORTUNER_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2005 to 2026.

Voltage of battery sensor FORTUNER_V_BATSENS

  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333310922500
Range
0 to 79.9979 V
Unit
V

In testing for 2005 to 2026.

Climate

Adjusted ambient temperature FORTUNER_ADJUSTED_AMBIENT_TConfirmed

  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×81.6255−30.8
Range
-30.8 to 50.8 °C
Unit
°C

0xBE = 190 → 190×81.6255−30.8 = 30 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Air conditioner feedback FORTUNER_AC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Air inlet damper actual pulse FORTUNER_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x82 = 130 → 130

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Air inlet damper target pulse FORTUNER_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x82 = 130 → 130

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Air outlet servo actu pulse, driver FORTUNER_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7A = 122 → 122

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Air outlet servo pulse, driver FORTUNER_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7A = 122 → 122

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Ambient air temperature FORTUNER_AATConfirmed

  • Service 21PID 22
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−23.3
Range
-23.3 to 65.95 °C
Unit
°C

0x99 = 153 → 153×89.25255−23.3 = 30.25 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Ambient temperature FORTUNER_AMBIENT_T_700Confirmed

  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x48 = 72 → 72−40 = 32 °C

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Ambient temperature for A/C FORTUNER_AC_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Blower motor speed level FORTUNER_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Cabin temperature FORTUNER_CABIN_TConfirmed

  • Service 21PID 21
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×63.75255−6.5
Range
-6.5 to 57.25 °C
Unit
°C

0x79 = 121 → 121×63.75255−6.5 = 23.75 °C

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Communication with air conditioner FORTUNER_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Communication with brake FORTUNER_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Communication with HV FORTUNER_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Communication with valvematic FORTUNER_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Evaporator fin thermistor FORTUNER_EVAP_FIN_THERMISTORConfirmed

  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−29.7
Range
-29.7 to 59.55 °C
Unit
°C

0x54 = 84 → 84×89.25255−29.7 = -0.3 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Set temperature, driver side FORTUNER_T_DRIVER

  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Solar sensor, driver side FORTUNER_SOLAR_DRIVERConfirmed

  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Control

A/C compressor FORTUNER_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

ABS warning FORTUNER_ABS_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Accelerator pedal FORTUNER_ACCEL_PEDAL

  • Service 22DID 1059
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1.42−28.873
Range
0 to 100 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Brake warning FORTUNER_BRAKE_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Buzzer FORTUNER_BUZZER

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Check engine FORTUNER_CHECK_ENGINEConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Cruise control live brake cancel FORTUNER_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

ECB warning FORTUNER_ECB_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electrical load signal 1 FORTUNER_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Electrical load signal 2 FORTUNER_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Ignition trigger count FORTUNER_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Key remind sound FORTUNER_KEY_REMIND_SOUNDConfirmed

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x08 = 8 → 8

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Neutral position FORTUNER_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Parking brake FORTUNER_PARKING_BRAKE

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Parking brake FORTUNER_PARKING_BRAKE_2Confirmed

  • Service 21PID 62
  • Module7D0 → 7D8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Pattern switch FORTUNER_PATTERN_SWITCH_PWR_M_

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Power steering FORTUNER_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Shift SW status, d range FORTUNER_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Shift SW status, n range FORTUNER_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Shift SW status, p range FORTUNER_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Shift SW status, r range FORTUNER_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Slip indicator FORTUNER_SLIP_INDICATOR

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Sports mode selection FORTUNER_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Sports shift down FORTUNER_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Sports shift up FORTUNER_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Starter control FORTUNER_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Starter signal FORTUNER_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Steering angle FORTUNER_STEERING_ANGLE

  • Service 22DID 1004
  • Module7B3 → 7BB
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1.5
Range
-410 to 410 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Steering wheel angle FORTUNER_STEER_ANGLE

Positive = counter-clockwise, negative = clockwise.

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Stop light FORTUNER_STOP_LIGHT

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Stop light FORTUNER_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Tail cancel FORTUNER_TAIL_CANCELConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

TC FORTUNER_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Traction brake control FORTUNER_TRC_BRAKE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Traction control FORTUNER_TRC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Traction engine control FORTUNER_TRC_ENGINE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Zero point of deceleration FORTUNER_ZP_DEC

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Zero point of deceleration 2 FORTUNER_ZP_DEC2

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Zero point of yaw rate FORTUNER_ZP_YAW_RATE

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Cruise control

Cruise control speed FORTUNER_CC_S

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

DTCs

2nd air monitor_avail FORTUNER_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

2nd air monitor_incmpl FORTUNER_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

A/C monitor_avail FORTUNER_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

A/C monitor_incmpl FORTUNER_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst monitor_avail FORTUNER_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst monitor_incmpl FORTUNER_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Complete parts monitor_avail FORTUNER_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

EGR/VVT monitor_avail FORTUNER_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

EGR/VVT monitor_incmpl FORTUNER_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

EVAP monitor_avail FORTUNER_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

EVAP monitor_icmpl FORTUNER_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Fuel system monitor_avail FORTUNER_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Heated catalyst monitor_avail FORTUNER_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Heated catalyst monitor_incmpl FORTUNER_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

MIL FORTUNER_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

MIL ON run distance FORTUNER_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Misfire monitor_avail FORTUNER_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Number of emission DTC FORTUNER_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

O2S(A/FS) heater monitor_avail FORTUNER_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

O2S(A/FS) heater monitor_incmpl FORTUNER_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

O2S(A/FS) monitor_avail FORTUNER_O2S_A_FS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

O2S(A/FS) monitor_incmpl FORTUNER_O2S_A_FS_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Running time from MIL ON FORTUNER_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

ECU

Exhaust VVT change angle bank 1 FORTUNER_EXHAUST_VVT_CHANGE_ANGLE_1

  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Exhaust VVT hold learn value bank 1 FORTUNER_EXHAUST_VVT_HOLD_LEARN_VALUE_1

  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535
Range
0 to 100 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Exhaust VVT timing most over-advanced learn value bank 1 FORTUNER_EXHAUST_VVT_TIMING_MOST_OVER_ADVANCED_LEARN_VALUE_1

  • Service 22DID 108F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Intake VVT most over-retarded learn value bank 1 FORTUNER_INTAKE_VVT_MOST_OVER_RETARDED_LEARN_VALUE_1

  • Service 22DID 108D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

VVT-ie duty ratio bank 1 FORTUNER_VVT_IE_DUTY_RATIO_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
val×399.965535−200
Range
-200 to -0.0531 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

VVT-ie motor direction: forward bank 1 FORTUNER_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electrical

B+ battery voltage FORTUNER_BATTERY_VOLTAGE_7C0

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 20 V
Unit
V

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electric load feedback FORTUNER_ELEC_LOAD_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine

A/F heater duty bank 1 sensor 1 FORTUNER_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2005 to 2026.

A/F ratio learn value high, bank 1 FORTUNER_AFRL_HIGH_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learn value idle, bank 1 FORTUNER_AFRL_IDLE_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learn value low, bank 1 FORTUNER_AFRL_LOW_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learn value mid.1, bank 1 FORTUNER_AFRL_MID_1_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learn value mid.2, bank 1 FORTUNER_AFRL_MID_2_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learned high, bank 1 FORTUNER_A_F_RATIO_LEARNED_HIGH_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learned idle, bank 1 FORTUNER_A_F_RATIO_LEARNED_IDLE_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learned low, bank 1 FORTUNER_A_F_RATIO_LEARNED_LOW_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learned mid 1, bank 1 FORTUNER_A_F_RATIO_LEARNED_MID_1_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F ratio learned mid 2, bank 1 FORTUNER_A_F_RATIO_LEARNED_MID_2_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

A/F test results 1, incomplete FORTUNER_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Accelerator sensor volt %, 1 FORTUNER_ACCEL_SENS_NO_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator sensor volt %, 2 FORTUNER_ACCEL_SENS_NO_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Accessory relay on FORTUNER_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Accumulator open FORTUNER_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Acoustic control induction system vacuum switching valve on FORTUNER_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Actual engine torque FORTUNER_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2005 to 2026.

Actuator power supply on FORTUNER_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

AF lambda B1S1 FORTUNER_AF_LAMBDA_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

AFS current B1S1 FORTUNER_AFS_CURRENT_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 127.99 mA
Unit
mA

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Air conditioning compressor FORTUNER_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Air mix servo target pulse, driver FORTUNER_AIR_MIX_SERVO_TARG_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Air mix servo, actual pulse, d FORTUNER_AIR_MIX_SERVO_ACT_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Alt voltage - active test FORTUNER_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2005 to 2026.

Alt voltage - non active test FORTUNER_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2005 to 2026.

Alternator output duty FORTUNER_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2005 to 2026.

Alternator output duty cycle FORTUNER_ALT_DUTY_CYCLEConfirmed

  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val164
Range
0 to 399 %
Unit
%

0x0A80 = 2688 → 2688164 = 16.390244 %

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Ambient temperature FORTUNER_AMBIENT_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Atmosphere pressure FORTUNER_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Calculated load_7e0 FORTUNER_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature B1S1 FORTUNER_CATALYST_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature B1S2 FORTUNER_CATALYST_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature bank 2 sensor 1 FORTUNER_CAT_T_BANK_2_SENS_1

  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2005 to 2026.

Catalyst temperature bank 2 sensor 2 FORTUNER_CAT_T_BANK_2_SENS_2

  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2005 to 2026.

Catalyst temperature, bank 1 sensor 2, variant 2 FORTUNER_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2026.

Check mode on FORTUNER_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Closed throttle position switch on FORTUNER_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Codes, include history FORTUNER_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Continuously variable transmission learning complete FORTUNER_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2005 to 2026.

Continuously variable transmission oil pressure FORTUNER_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2005 to 2026.

Coolant temp FORTUNER_COOLANT_TEMP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Coolant temperature FORTUNER_COOLANT_TConfirmed

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 127.5 °C
Unit
°C

0x00 = 0 → 0×0.5 = 0 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Coolant water route switching valve 1, closed? FORTUNER_COOLANT_VALVE_1_CLOSE

  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Coolant water route switching valve 2, closed? FORTUNER_COOLANT_VALVE_2_CLOSE

  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Cooling fan duty ratio FORTUNER_COOLING_FAN_DUTY_RATIO

  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×127.5255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Cruise control on FORTUNER_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Cylinder 1 injection volume FORTUNER_CYL_1_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2005 to 2026.

Cylinder 2 injection volume FORTUNER_CYL_2_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2005 to 2026.

Cylinder 3 injection volume FORTUNER_CYL_3_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2005 to 2026.

Cylinder 4 injection volume FORTUNER_CYL_4_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2005 to 2026.

Cylinder number FORTUNER_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Destination FORTUNER_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Diesel particulate and nitrogen oxide reduction regeneration status FORTUNER_DPF_REGEN_STAT

  • Service 22DID 119B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Diesel particulate filter accumulation level FORTUNER_DPF_ACCUMULATION

  • Service 21PID 38
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×2
Range
0 to 100 %
Unit
%

In testing for 2005 to 2026.

Diesel particulate filter differential pressure FORTUNER_DPF_DIFF_P

  • Service 22DID 1F7A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 kPa
Unit
kPa

In testing for 2005 to 2026.

Dist battery cable disconnect FORTUNER_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2005 to 2026.

Electric fan motor on FORTUNER_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Electric thermostat duty ratio FORTUNER_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electric water pump FORTUNER_ELECTRIC_WATER_PUMP

  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 rpm
Unit
rpm

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electric water pump RPM FORTUNER_EWP_RPM

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Electric water pump target speed FORTUNER_EWP_TARGET_VSS

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Engine coolant temp FORTUNER_ECTConfirmed

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

0xEA = 234 → 234×89.25255+1.3 = 83.2 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Engine coolant temperature, ignition on FORTUNER_ECT_IGNConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x6D = 109 → 109×62.5100−40 = 28.125 °C

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Engine coolant temperature, initial FORTUNER_ECT_INITConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x6D = 109 → 109×62.5100−40 = 28.125 °C

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Engine independent FORTUNER_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Engine independent control FORTUNER_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Engine oil pressure FORTUNER_EOPConfirmed

  • Service 22DID 1074
  • Module700 → 708
  • Every250 ms
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10128
Range
0 to 5119.92 kPa
Unit
kPa

0x064E = 1614 → 1614×10128 = 126.09375 kPa

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Engine oil pressure control valve FORTUNER_EOP_CONTROL_VALVE

  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0762939
Range
0 to 4999.9207 mA
Unit
mA

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Engine oil temperature FORTUNER_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil temperature FORTUNER_EOT_700

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Engine oil temperature, previous trip FORTUNER_PREV_TRIP_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil temperature, variation 2 FORTUNER_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Engine run time FORTUNER_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine run time, up to 255 sec. only FORTUNER_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2005 to 2026.

Engine stall control FB flow FORTUNER_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2005 to 2026.

Engine start hesitation FORTUNER_ENG_START_HESIT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine starting time FORTUNER_ENG_START_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

EVAP purge duty FORTUNER_EVAP_PURGE_DUTY

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Evaporative purge duty FORTUNER_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2005 to 2026.

Evaporative purge flow FORTUNER_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 2005 to 2026.

Evaporative purge vacuum switching valve on FORTUNER_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Evaporator target temp FORTUNER_EVAP_TARG_TConfirmed

  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67
Unit
Number

0x8096 = 32918 → 32918100−327.68 = 1.5

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Exhaust gas recirculation step position FORTUNER_EGR_STEP_POSITION

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Exhaust gas recirculation temperature FORTUNER_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2005 to 2026.

Exhaust gas recirculation valve step FORTUNER_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2026.

Exhaust VVT oil control valve control duty FORTUNER_EXHAUST_VVT_OCV_CONTROL_DUTY

  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×40065535
Range
0 to 400 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Exhaust VVT target angle B1 FORTUNER_EXHAUST_VVT_TARGET_ANGLE_B1

  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Fuel cut for engine stop request FORTUNER_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Fuel cut TAU on FORTUNER_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Fuel filter temperature FORTUNER_FFT

  • Service 22DID 109A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

G sensor calibration, complete FORTUNER_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

G sensor learning value FORTUNER_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2005 to 2026.

Glass humidity FORTUNER_GLASS_HUMIDITY

  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2005 to 2026.

Glass temperature FORTUNER_GLASS_T

  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9500−557.8
Range
-557 to 621 °F
Unit
°F

In testing for 2005 to 2026.

HV communication open FORTUNER_HV_COMMUNICATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Idle control FORTUNER_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Idle spark advance control 1 FORTUNER_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2005 to 2026.

Idle spark advance control 2 FORTUNER_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2005 to 2026.

Idle spark advance control 3 FORTUNER_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2005 to 2026.

Idle spark advance control 4 FORTUNER_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2005 to 2026.

Idle spark advance control, cylinder 1 FORTUNER_IDLE_SAC_CYL_1

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Idle spark advance control, cylinder 2 FORTUNER_IDLE_SAC_CYL_2

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Idle spark advance control, cylinder 3 FORTUNER_IDLE_SAC_CYL_3

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Idle spark advance control, cylinder 4 FORTUNER_IDLE_SAC_CYL_4

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Idle speed control feedback FORTUNER_ISC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Idle speed control flow FORTUNER_ISC_FLOW

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val×108192
Range
0 to 79.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Idle speed control learning FORTUNER_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Idle speed control learning value FORTUNER_ISC_LEARN

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Idle speed control learning value, l/s FORTUNER_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 2005 to 2026.

Idle speed control position FORTUNER_ISC_POS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

IG OFF elapsed time FORTUNER_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 2005 to 2026.

Ignition advance FORTUNER_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Ignition advance FORTUNER_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2005 to 2026.

Immobilizer communication on FORTUNER_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Initial engine coolant temperature FORTUNER_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 2005 to 2026.

Initial intake air temperature FORTUNER_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2005 to 2026.

Injection FORTUNER_INJECTION

  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Injection duration for cylinder 1 FORTUNER_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2005 to 2026.

Injection feedback value 1 FORTUNER_INJ_FEEDBACK_1

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 1 FORTUNER_INJ_FEEDBACK_1_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 2 FORTUNER_INJ_FEEDBACK_2

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 2 FORTUNER_INJ_FEEDBACK_2_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 3 FORTUNER_INJ_FEEDBACK_3

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 3 FORTUNER_INJ_FEEDBACK_3_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 4 FORTUNER_INJ_FEEDBACK_4

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 4 FORTUNER_INJ_FEEDBACK_4_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 5 FORTUNER_INJ_FEEDBACK_5

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection feedback value 6 FORTUNER_INJ_FEEDBACK_6

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2005 to 2026.

Injection volume FORTUNER_INJ_VOL

  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3200
Range
0 to 20 L
Unit
L

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Injection volume - target FORTUNER_INJ_VOLUME_TGT

  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injection volume 1 FORTUNER_INJ_VOLUME_1

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2005 to 2026.

Injection volume 2 FORTUNER_INJ_VOLUME_2

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2005 to 2026.

Injection volume 3 FORTUNER_INJ_VOLUME_3

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2005 to 2026.

Injection volume 5 FORTUNER_INJ_VOLUME_5

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2005 to 2026.

Injection volume 6 FORTUNER_INJ_VOLUME_6

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2005 to 2026.

Injection volume per 10 injections, cylinder 1 FORTUNER_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 2005 to 2026.

Injection volume total FORTUNER_INJ_VOLUME_TOT

  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2005 to 2026.

Injector port FORTUNER_INJECTOR_PORT

  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Injector pulse width FORTUNER_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2005 to 2026.

Injector pulse width FORTUNER_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2005 to 2026.

Input shaft speed FORTUNER_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2005 to 2026.

Intake air FORTUNER_INTAKE_AIR

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Intake air temperature FORTUNER_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Intake air temperature, bank 1 sensor 1 FORTUNER_IAT_B1S1

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Intake air temperature, bank 1 sensor 2 FORTUNER_IAT_B1S2

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Intake air temperature, previous trip FORTUNER_PREV_TRIP_IAT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Intake VVT change angle, bank 1 FORTUNER_INTAKE_VVT_CHANGE_ANGLE_BANK_1

  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Intake VVT target angle B1 FORTUNER_INTAKE_VVT_TARGET_ANGLE_B1

  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Integrated engine run time FORTUNER_INTEGRATED_ENG_RUN

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2005 to 2026.

Intercooler coolant temperature FORTUNER_INTERCOOLER_ECT

  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Intercooler water pump FORTUNER_INTERCOOLER_WATER

  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8013107
Range
0 to 300 %
Unit
%

In testing for 2005 to 2026.

Internal temperature FORTUNER_ECU_INTERNAL_T

  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Judge time engine ignition FORTUNER_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2005 to 2026.

Judge time engine output FORTUNER_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2005 to 2026.

Knock adjust FORTUNER_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2005 to 2026.

Knock adjust FORTUNER_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2005 to 2026.

Knock correct learn value FORTUNER_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 2005 to 2026.

Knock correction, learned value FORTUNER_KNOCK_CORRECT_LEARNED_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Knock feedback FORTUNER_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2005 to 2026.

Knock feedback FORTUNER_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2005 to 2026.

Knock feedback value FORTUNER_KNOCK_FEEDBACK_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Long FT B1S1 FORTUNER_LONG_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Long-term fuel trim, bank 1 FORTUNER_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2005 to 2026.

Low revolution control FORTUNER_LOW_RPM_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Low revolution for engine start FORTUNER_LOW_RPM_START

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Main idle FORTUNER_MAIN_IDLE

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

MAP FORTUNER_MAP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Mass air flow FORTUNER_MAF

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Mass air flow FORTUNER_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2005 to 2026.

Master cylinder open FORTUNER_MASTER_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Master cylinder sensor temperature FORTUNER_MASTER_CYL_TEMPConfirmed

  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−80
Range
-20 to 100 °C
Unit
°C

0x73 = 115 → 115−80 = 35 °C

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Misfire count, all cylinders FORTUNER_MISFIRE_CNT

  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire count, cylinder 1 FORTUNER_MISFIRE_CYL1

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire count, cylinder 2 FORTUNER_MISFIRE_CYL2

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire count, cylinder 3 FORTUNER_MISFIRE_CYL3

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire count, cylinder 4 FORTUNER_MISFIRE_CYL4

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire load FORTUNER_MISFIRE_LOAD_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×510255
Range
0 to 510 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire margin FORTUNER_MISFIRE_MARGIN_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 rpm
Unit
rpm

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire RPM FORTUNER_MISFIRE_RPM

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Misfire RPM FORTUNER_MISFIRE_RPM_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6375255
Range
0 to 6375 rpm
Unit
rpm

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfire test result, incomplete FORTUNER_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Model year FORTUNER_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 2005 to 2026.

O2 heater b1s2_active FORTUNER_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

O2 heater current val bank 1 sensor 2 FORTUNER_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 2005 to 2026.

O2S B1S2 FORTUNER_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Open side malfunction on FORTUNER_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Output shaft speed FORTUNER_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2005 to 2026.

OXS1, A/FS2 test result, incomplete FORTUNER_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Oxygen sensor voltage, bank 1 sensor 1 FORTUNER_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2005 to 2026.

PM accumulation ratio - bank 1 FORTUNER_PM_ACCUMULATION_RAT_1

  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 %
Unit
%

In testing for 2005 to 2026.

Purge cut vacuum switching valve duty FORTUNER_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2005 to 2026.

Racing operation FORTUNER_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Regulator pressure FORTUNER_REGULATOR_P

  • Service 21PID 53
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×37510525500−456.68
Range
-456.68 to 3294 kPa
Unit
kPa

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Request engine run time FORTUNER_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2005 to 2026.

Request warm-up FORTUNER_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Requested engine torque FORTUNER_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 2005 to 2026.

Rough idle cyl.1 FORTUNER_ROUGH_IDLE_1Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Rough idle cyl.2 FORTUNER_ROUGH_IDLE_2Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Rough idle cyl.3 FORTUNER_ROUGH_IDLE_3Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Rough idle cyl.4 FORTUNER_ROUGH_IDLE_4Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Short FT B1S1 FORTUNER_SHORT_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Starter count FORTUNER_STARTER_CNT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 33 to 39 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Starter relay on FORTUNER_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Stroke open FORTUNER_STROKE_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

System guard on FORTUNER_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Throttle fully close learn FORTUNER_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle idle position on FORTUNER_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Throttle motor current FORTUNER_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2005 to 2026.

Throttle motor DUTY FORTUNER_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Throttle motor duty, close FORTUNER_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2005 to 2026.

Throttle motor duty, open FORTUNER_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2005 to 2026.

Throttle position FORTUNER_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2005 to 2026.

Throttle position FORTUNER_TPS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position command FORTUNER_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle position, number 1 FORTUNER_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle position, number 2 FORTUNER_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle require position FORTUNER_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle sensor open position 1 FORTUNER_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle sensor open position 2 FORTUNER_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Throttle sensor position FORTUNER_THROTTLE_SENSOR_POSITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Throttle sensor volt %, 1 FORTUNER_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Throttle sensor volt %, 2 FORTUNER_THROTTL_SENSOR_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Time after DTC cleared FORTUNER_TIME_AFTER_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Total fuel trim, bank 1 FORTUNER_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 2005 to 2026.

Transmission fluid temperature FORTUNER_ATF_T

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature FORTUNER_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Transmission output shaft speed FORTUNER_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2005 to 2026.

Turbine speed FORTUNER_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2005 to 2026.

Valvematic current angle FORTUNER_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2026.

Valvematic, target angle FORTUNER_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2005 to 2026.

Variable valve timing advance fail FORTUNER_VVT_ADV_FAIL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing aim angle 1 FORTUNER_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 2005 to 2026.

Variable valve timing change angle 1 FORTUNER_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 2005 to 2026.

Variable valve timing control status 1 on FORTUNER_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Variable valve timing oil control valve duty 1 FORTUNER_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 2005 to 2026.

Variable valve timing oil temperature FORTUNER_VVTOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing opening angle bank 1 FORTUNER_VVT_IE_OPENING_ANGLE_BANK_1

  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Vehicle load FORTUNER_VEHICLE_LOAD

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle speed FORTUNER_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2005 to 2026.

Vehicle speed sensor test result, incomplete FORTUNER_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Warmup cycle cleared DTC FORTUNER_WARMUP_CYCLE_CLEARED_DTC

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst

Catalyst temperature, bank 1 sensor 1 FORTUNER_CAT_T_11

  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Catalyst temperature, bank 1 sensor 2 FORTUNER_CAT_T_12

  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Misfires

All cylinders misfire count FORTUNER_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Cylinder #1 misfire count FORTUNER_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Cylinder #2 misfire count FORTUNER_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Cylinder #3 misfire count FORTUNER_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Cylinder #4 misfire count FORTUNER_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Misfire load FORTUNER_MISFIRE_LOAD

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Misfire margin FORTUNER_MISFIRE_MARGIN

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Fluids

Distance since oil change FORTUNER_OIL_CHANGE_ODO

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Fuel

Engine fuel rate FORTUNER_ENG_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2005 to 2026.

Fuel cut FORTUNER_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Fuel cut FORTUNER_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2026.

Fuel cut time FORTUNER_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2005 to 2026.

Fuel injection timing FORTUNER_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2005 to 2026.

Fuel level FORTUNER_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1F2F
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Fuel level FORTUNER_FUEL_LEVEL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Fuel level, volume FORTUNER_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

0x40 = 64 → 64×5003785 = 8.454425 gal

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Fuel pressure 1 FORTUNER_FUEL_P_1

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 1 FORTUNER_FUEL_P_1_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 2 FORTUNER_FUEL_P_2

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 2 FORTUNER_FUEL_P_2_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 3 FORTUNER_FUEL_P_3

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 3 FORTUNER_FUEL_P_3_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 4 FORTUNER_FUEL_P_4

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 4 FORTUNER_FUEL_P_4_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 5 FORTUNER_FUEL_P_5

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pressure 6 FORTUNER_FUEL_P_6

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2005 to 2026.

Fuel pump duty ratio FORTUNER_FP_DUTY_RATIO

  • Service 22DID 106A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0609756098
Range
0 to 3996.0365 kPa
Unit
kPa

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Fuel pump/speed status on FORTUNER_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Fuel return temperature FORTUNER_FUEL_RETURN_T

  • Service 22DID 1141
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 1 FORTUNER_FUEL_T_1

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 1 FORTUNER_FUEL_T_1_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 2 FORTUNER_FUEL_T_2

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 2 FORTUNER_FUEL_T_2_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 3 FORTUNER_FUEL_T_3

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 3 FORTUNER_FUEL_T_3_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 4 FORTUNER_FUEL_T_4

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 4 FORTUNER_FUEL_T_4_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 5 FORTUNER_FUEL_T_5

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Fuel temperature 6 FORTUNER_FUEL_T_6

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

High fuel pressure, actual FORTUNER_HFP_ACTUALConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0DDB = 3547 → 3547×10 = 35,470 kPa

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

High fuel pressure, target FORTUNER_HFP_TARGETConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0DDD = 3549 → 3549×10 = 35,490 kPa

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Immobilizer fuel cut FORTUNER_IMMOB_FUEL_CUT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Low fuel pressure FORTUNER_LFP

  • Service 22DID 10CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
0 to 3276.7 kPa
Unit
kPa

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Low fuel pressure FORTUNER_LOW_FUEL_PRESSUREConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0D96 = 3478 → 3478×10 = 34,780 kPa

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Reservoir warning FORTUNER_RESERVOIR_WARNING

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Target air-fuel ratio FORTUNER_TARGET_AIR_FUEL_RATIO

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle fuel rate FORTUNER_VEH_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2005 to 2026.

Lights

Hazard switch history FORTUNER_HAZARD_SWITCH_HISTORY

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rheostat FORTUNER_RHEOSTAT

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Stop light relay FORTUNER_STOP_LIGHT_RELAY

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Movement

Accelerator fully close learn 1 FORTUNER_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2005 to 2026.

Accelerator fully close learn 2 FORTUNER_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2005 to 2026.

Accelerator idle position on FORTUNER_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Accelerator position FORTUNER_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2005 to 2026.

Accelerator sensor out, number 1 FORTUNER_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Accelerator sensor out, number 2 FORTUNER_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2005 to 2026.

Average engine speed of all cylinders FORTUNER_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Compressor speed FORTUNER_COMP_SPD

  • Service 21PID 49
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2005 to 2026.

Compressor, target speed FORTUNER_COMP_TGT_SPD

  • Service 21PID 4A
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2005 to 2026.

Cruise control speed FORTUNER_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2005 to 2026.

Engine speed FORTUNER_ENGINE_SPEED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 16383 rpm
Unit
rpm

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed of cylinder 1 FORTUNER_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Engine speed of cylinder 2 FORTUNER_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Engine speed of cylinder 3 FORTUNER_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Engine speed of cylinder 4 FORTUNER_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Engine speed, starter off FORTUNER_ENG_SPD_START_OFF

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100128
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

FL wheel acceleration FORTUNER_FL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

FR wheel acceleration FORTUNER_FR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front left wheel speed FORTUNER_FL_VSS

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front left wheel speed? FORTUNER_FL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel speed FORTUNER_FR_VSS

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel speed? FORTUNER_FR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

High voltage, target engine speed FORTUNER_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2005 to 2026.

Intercooler water pump speed, raw count FORTUNER_IWP_SPEED

  • Service 22DID 1075
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Minimum engine speed FORTUNER_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2005 to 2026.

Rear left wheel speed FORTUNER_RL_VSS

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear left wheel speed? FORTUNER_RL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear right wheel speed FORTUNER_RR_VSS

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear right wheel speed? FORTUNER_RR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

RL wheel acceleration FORTUNER_RL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

RR wheel acceleration FORTUNER_RR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Vehicle speed FORTUNER_VEHICLE_SPEED

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle speed FORTUNER_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.28
Range
0 to 326 km/h
Unit
km/h

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Vehicle speed, 7C0 FORTUNER_VSS_7C0Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Orientation

Deceleration open FORTUNER_DECELERATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Deceleration sensor FORTUNER_DECEL

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Deceleration sensor, alternate FORTUNER_DECEL2

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Lateral g FORTUNER_LAT_G

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Longitudinal g FORTUNER_LNG_G

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Yaw rate open error? FORTUNER_YAW_RATE_ERROR

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Yaw rate sensor FORTUNER_YAW_RATE

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Yaw rate sensor, alternate FORTUNER_YAW_RATE2

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Yaw rate value, degrees/sec FORTUNER_YAW_RATE3

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Zero point of yaw rate FORTUNER_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Seatbelts

Buckle switch, left side FORTUNER_BUCKLE_LS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Buckle switch, right side FORTUNER_BUCKLE_RS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

P-seatbelt buckle FORTUNER_P_SEATBELT_BUCKLEConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Reverse beep FORTUNER_REVERSE_BEEP

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Seat belt beeps FORTUNER_SEAT_BELT_BEEPConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2005 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xE0 = 224 → 224

Confirmed for 2021 to 2022. In testing for 2005 to 2020, 2023 to 2026.

Stats

Inspection mode FORTUNER_INSPECTION_MODE

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Tires

Brake assist status FORTUNER_BA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front left wheel ABS status FORTUNER_FL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front left wheel VSC control FORTUNER_FL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel ABS status FORTUNER_FR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel cylinder open FORTUNER_FR_WHEEL_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel VSC control FORTUNER_FR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Predictive brake assist status FORTUNER_PBA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear left wheel ABS status FORTUNER_RL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear left wheel EBS status FORTUNER_RL_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear left wheel VSC control FORTUNER_RL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear right wheel ABS status FORTUNER_RR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear right wheel EBS status FORTUNER_RR_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Rear right wheel VSC control FORTUNER_RR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Torque converter turbine wheel speed FORTUNER_TQ_CONV_TURBINE_WHL

  • Service 21PID DA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12750
Range
0 to 6 rpm
Unit
rpm

In testing for 2005 to 2026.

Wheel cylinder pressure FORTUNER_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Transmission

Current gear FORTUNER_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Gear FORTUNER_GEAR

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Gear FORTUNER_GEAR_700Confirmed

  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Gear lock-up FORTUNER_GEAR_LOCKUP

Mechanism within the automatic transmission that momentarily locks the gears during gear changes, providing a smoother and more efficient transition between different gears, especially when accelerating or decelerating; essentially helps minimize power loss and jerkiness during gear shifts.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Lock up state FORTUNER_AT_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Neutral control FORTUNER_NEUTRAL_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Neutral range status FORTUNER_N_RANGE_STS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Torque converter and TE1 on FORTUNER_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Transmission fluid post-converter temperature, variant 3 FORTUNER_TRANS_FLUID_POST_T_3

  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, pan var.3 FORTUNER_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing for 2005 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Fortuner.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x69A0 = 27040 → 27040256−40 = 65.625 °C

Confirmed for 2022. In testing for 2005 to 2020, 2023 to 2026. Not supported for 2021.

Transmission fluid temperature, variant 5 FORTUNER_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 8 FORTUNER_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 9 FORTUNER_ATF_T_V_9

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 10 FORTUNER_ATF_T_V_10_7E1

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 11 FORTUNER_ATF_T_V_11

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 12 FORTUNER_ATF_T_V_12

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 14 FORTUNER_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 14 FORTUNER_ATF_T_V_14_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 21 FORTUNER_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Transmission fluid temperature, variant 21 FORTUNER_ATF_T_V_21_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2026.

Transmission oil pressure calibration, complete FORTUNER_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2005 to 2026.

Transmission shift state ratio FORTUNER_TRANS_SHIFT_ST_RAT

  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2005 to 2026.

Transmission temperature, pan FORTUNER_ATF_PAN_T

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Transmission temperature, torque converter FORTUNER_ATF_TQC_T

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Trips

Ambient temperature, previous trip FORTUNER_PREV_TRIP_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Odometer FORTUNER_ENG_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module700 → 708
  • Every30 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2005 to 2026.

Odometer FORTUNER_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2021, 2023 to 2026. Not supported for 2022.

Previous trip distance FORTUNER_PREV_TRIP_DST

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

In testing for 2005 to 2021, 2023 to 2026. Not supported for 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.