Toyota GR Supra

Parameters

The Toyota GR Supra has 89 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature SUPRA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID DA25
  • Module6F1 → 618
  • Every30 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−48
Range
-49 to 250 °C
Unit
°C

0x0030 = 48 → 48−48 = 0 °C

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Climate

Ambient air temperature SUPRA_AAT

  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Control

Brake switch SUPRA_BRAKE_SWITCHConfirmed

  • Service 22DID DA28
  • Module6F1 → 618
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Doors

Driver door open SUPRA_DOOR_DRIVER

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Hood open SUPRA_HOOD

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Locked SUPRA_CENTRAL_LOCK

Overall lock state of the vehicle

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Passenger door open SUPRA_DOOR_PASSENGER

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear driver door open SUPRA_DOOR_DRIVER_REAR

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear passenger door open SUPRA_DOOR_PASSENGER_REAR

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Trunk open SUPRA_TRUNK

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Engine

Barometric pressure SUPRA_BARO

  • Service 22DID 4201
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 1996 to 2002, 2020 to 2026.

Boost pressure SUPRA_BOOST_P

  • Service 22DID 4205
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 1996 to 2002, 2020 to 2026.

Boost pressure, set point SUPRA_BOOST_P_SET

  • Service 22DID 4AB0
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 1996 to 2002, 2020 to 2026.

Catalyst temperature SUPRA_CAT_T

  • Service 22DID 582F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Crank torque SUPRA_CRANK_TQ

  • Service 22DID 58BA
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 1996 to 2002, 2020 to 2026.

Engine load SUPRA_LOAD

  • Service 22DID 5813
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 %
Unit
%

In testing for 1996 to 2002, 2020 to 2026.

Engine load 2 SUPRA_LOAD_2

  • Service 22DID 4A4B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2002, 2020 to 2026.

Engine load, target SUPRA_LOAD_TGT

  • Service 22DID 480C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3128
Range
0 to 1535 %
Unit
%

In testing for 1996 to 2002, 2020 to 2026.

Engine oil pressure SUPRA_EOPConfirmed

  • Service 22DID 586F
  • Module6F1 → 612
  • Every30 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

0x0382 = 898 → 8981000 = 0.898 bar

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Engine oil temperature SUPRA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID DA25
  • Module6F1 → 618
  • Every30 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−48
Range
-49 to 250 °C
Unit
°C

0x0030 = 48 → 48−48 = 0 °C

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Engine oil temperature SUPRA_EOT_DME

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Ignition angle SUPRA_IGN_ANGLE

  • Service 22DID 59FA
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 1996 to 2002, 2020 to 2026.

Ignition timing, cylinder 1 SUPRA_IGN_TIMING_1

  • Service 22DID 4A49
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 1996 to 2002, 2020 to 2026.

Ignition timing, cylinder 2 SUPRA_IGN_TIMING_2

  • Service 22DID 4A4A
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 1996 to 2002, 2020 to 2026.

Ignition timing, cylinder 3 SUPRA_IGN_TIMING_3

  • Service 22DID 4A4C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 1996 to 2002, 2020 to 2026.

Ignition timing, cylinder 4 SUPRA_IGN_TIMING_4

  • Service 22DID 4A4D
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 1996 to 2002, 2020 to 2026.

Intake air temperature SUPRA_IAT_DME

  • Service 22DID 580F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Intake manifold pressure SUPRA_MAP

  • Service 22DID 4A2D
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 1996 to 2002, 2020 to 2026.

Kickdown SUPRA_KICKDOWNConfirmed

  • Service 22DID DA1F
  • Module6F1 → 618
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Lambda SUPRA_LAMBDA

  • Service 22DID 5889
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Lambda 2 SUPRA_LAMBDA_2

  • Service 22DID 582C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Oil level SUPRA_OIL_LEVEL

  • Service 22DID 442C
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rev limiter SUPRA_REV_LIMIT

  • Service 22DID 4A2E
  • Module6F1 → 612
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1996 to 2002, 2020 to 2026.

Time in d SUPRA_TIME_D

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Time in m SUPRA_TIME_M

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Time in s SUPRA_TIME_S

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Transmission fluid temperature SUPRA_ATF_TEMP

  • Service 22DID DA12
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Variable geometry turbocharger calibration angle SUPRA_VGT_CAL_ANGLE

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×156.2510000
Range
0 to 1000 °
Unit
°

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Fluids

Distance since last oil change SUPRA_OIL_CHANGE_DIST

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every1 s
  • Testing

Bits 304 to 335 of the reply, 32 bits.

Formula
val
Range
0 to 1000000 km
Unit
km

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Fuel

Fuel rail pressure SUPRA_FRP

  • Service 22DID 56D7
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Movement

Front left wheel speed SUPRA_FL_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Front right wheel speed SUPRA_FR_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Rear left wheel speed SUPRA_RL_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Rear right wheel speed SUPRA_RR_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Vehicle speed SUPRA_VSSConfirmed

Speedometer vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID D107
  • Module6F1 → 660
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Vehicle speed SUPRA_VSS2Confirmed

High resolution vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID 4AB1
  • Module6F1 → 612
  • Every250 ms
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Vehicle speed, instrument cluster SUPRA_VSS_INSTR

Instrument cluster vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID D240
  • Module6F1 → 60D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1000 km/h
Unit
km/h

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Tires

Front axle, actual torque SUPRA_AXLE_FRONT_ACTUAL_TORQUE

  • Service 22DID DB32
  • Module6F1 → 619
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8000 to 8000 N·m
Unit
N·m

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Front axle, set point torque SUPRA_AXLE_FRONT_SETPOINT_TORQUE

  • Service 22DID DB32
  • Module6F1 → 619
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8000 to 8000 N·m
Unit
N·m

In testing for 1996 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Front left tire pressure SUPRA_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Front left tire pressure, set point SUPRA_TP_SET_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Front left tire sensor battery life, months SUPRA_TPMS_BAT_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Front left tire sensor position SUPRA_TPMS_POS_FL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Front left tire temperature SUPRA_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Front right tire pressure SUPRA_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Front right tire pressure, set point SUPRA_TP_SET_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Front right tire sensor battery life, months SUPRA_TPMS_BAT_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Front right tire sensor position SUPRA_TPMS_POS_FR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Front right tire temperature SUPRA_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Rear left tire pressure SUPRA_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Rear left tire pressure, set point SUPRA_TP_SET_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Rear left tire sensor battery life, months SUPRA_TPMS_BAT_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear left tire sensor position SUPRA_TPMS_POS_RL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear left tire temperature SUPRA_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Rear right tire pressure SUPRA_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Rear right tire pressure, set point SUPRA_TP_SET_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 1996 to 2002, 2020 to 2026.

Rear right tire sensor battery life, months SUPRA_TPMS_BAT_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear right tire sensor position SUPRA_TPMS_POS_RR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Rear right tire temperature SUPRA_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2002, 2020 to 2026.

Transmission

Current gear SUPRA_GEAR_V2

  • Service 22DID D031
  • Module6F1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Gear SUPRA_GEARConfirmed

  • Service 22DID DA2E
  • Module6F1 → 618
  • Every30 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Torque converter lockup SUPRA_TQ_CNVRT_LOCKUPConfirmed

  • Service 22DID DA22
  • Module6F1 → 618
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → OPEN

States
Raw valueStateMeaning
0OPENOpen
1CONTROL_LOWControlled low
2CONTROL_HIGHControlled high
3CLOSED_LOWClosed low
4CLOSED_HIGHClosed high
8TRANSITION_OPENTransition to open

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Torque converter speed SUPRA_TQ_CNVRT_RPMConfirmed

  • Service 22DID DA2A
  • Module6F1 → 618
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Transmission output shaft speed SUPRA_TRANS_SHAFT_RPMConfirmed

  • Service 22DID DA2A
  • Module6F1 → 618
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Trips

Auxiliary power consumption SUPRA_AUX_PWR

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 1996 to 2002, 2020 to 2026.

Current electric range SUPRA_RANGE_E_CUR

Current estimated electric range

Pelican can show this parameter as the electric range.

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Current fuel range SUPRA_RANGE_F_CUR

Requires range extender.

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Electric consumption / 100km SUPRA_RANGE_E_USE

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 kWh
Unit
kWh

In testing for 1996 to 2002, 2020 to 2026.

Engine operating hours SUPRA_ENG_HOURS

  • Service 22DID 558F
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2
Range
0 to 2147483647 h
Unit
h

In testing for 1996 to 2002, 2020 to 2026.

Estimated range remaining SUPRA_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Estimated range remaining in comfort mode SUPRA_RANGE_COMF

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Estimated range remaining in economy mode SUPRA_RANGE_ECO

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Maximum electric range SUPRA_RANGE_E_MAX

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Maximum fuel range SUPRA_RANGE_F_MAX

Requires range extender.

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Odometer SUPRA_ODOConfirmed

  • Service 22DID DA23
  • Module6F1 → 618
  • Every15 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 31 of the reply, 32 bits.

Formula
val×8
Range
0 to 1000000 km
Unit
km

0x00000302 = 770 → 770×8 = 6,160 km

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Odometer #1 SUPRA_ODO1Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00001811 = 6161 → 6,161 km

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Odometer #2 SUPRA_ODO2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00001811 = 6161 → 6,161 km

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Odometer variant SUPRA_ODO_2Confirmed

  • Service 22DID 1700
  • Module6F1 → 640
  • Every1 s
  • Testing for 1996 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000000 km
Unit
km

0x00001808 = 6152 → 6,152 km

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1996 to 2002, 2023 to 2024.

Odometer, engine computer SUPRA_ODO_DME

  • Service 22DID 558E
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 1996 to 2002, 2020 to 2026.

Windows

Rear window open SUPRA_REAR_WINDOW

  • Service 22DID DCDD
  • Module6F1
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2002, 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.