Parameters
The Volkswagen Arteon has 860 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery capacity ARTEON_12V_BAT_CAP
- Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Accelerator pedal, sensor 1 voltage ARTEON_ACCEL_PEDAL_SENS_1_V
- Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
Accelerator pedal, sensor 2 voltage ARTEON_ACCEL_PEDAL_SENS_2_V
- Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
All-wheel drive voltage ARTEON_PQ35_HAL_VConfirmed
- Service 22
DID 2BE9 - Module
70F → 779 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x00 = 0 → = 0 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Aux. hydraulic pump voltage ARTEON_AUX_HYDRAULIC_PMP_V
- Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Battery internal resistance ARTEON_SSB_RES_INTConfirmed
- Service 22
DID 2A0E - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -25.6 to 25.4
- Unit
- Number
0x1B = 27 → = 5.4
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Battery internal resistance, raw ARTEON_BAT_INTERNAL_RES_RAW
- Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
In testing for 2017 to 2026.
Battery sensor temperature ARTEON_BAT_TConfirmed
- Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3F = 63 → = 23 °C
Confirmed for 2020. In testing for 2017 to 2019, 2022 to 2026. Not supported for 2021.
Battery voltage ARTEON_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 2017 to 2026.
Bypass valve high pressure turbine inlet, raw voltage ARTEON_BYPASS_VLV_HIGH_P_V
- Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge adjuster output stage ARTEON_HIGH_P_TURBOCHARGER
- Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value ARTEON_CHG_AIR_COOLER_INLET_P_1_1
- Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2017 to 2026.
Charge air pressure ARTEON_PQ35_CHG_AIR_PConfirmed
- Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Charge air pressure actuator position digit.value ARTEON_CHG_AIR_P_ACTUATOR_7E0
- Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Charge air pressure actuator, acknowledgment ARTEON_CHG_AIR_P_ACTUATOR
- Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Charge air pressure, actual value ARTEON_AIR_P_CAC_DS
- Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Charge air pressure, actual value ARTEON_CHG_AIR_P_ACT
- Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2017 to 2026.
Charge air pressure, specified value ARTEON_CHG_AIR_P_SPEC
- Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Charge air pressure: actual ARTEON_PQ35_CHARGE_AIR_P_ACTUALConfirmed
- Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
0x03F1 = 1009 → = 80.72
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Charge air pressure: specified ARTEON_PQ35_CHARGE_AIR_P_SPECIFIEDConfirmed
- Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
0x0545 = 1349 → = 107.92
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Charge pressure actuator, actual position ARTEON_CHG_P_ACTUATOR_ACT
- Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure actuator, adaptation for lower stop ARTEON_CHG_P_ACTUATOR_ADPT
- Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge pressure actuator, adaptation for upper stop ARTEON_CHG_P_ACTUATOR_ADPT_HI
- Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge pressure actuator, maximum sensor voltage ARTEON_CHG_P_ACTUATOR_MAX_V
- Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge pressure actuator, specified position ARTEON_CHG_P_ACTUATOR_SPEC
- Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure actuator, specified value ARTEON_CHG_P_ACTUATOR_SPEC_7E0
- Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure before throttle valve, calculated actual value ARTEON_CHG_P_BEFORE_ACT
- Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 2017 to 2026.
Charge pressure control adaptation higher than max. threshold ARTEON_CHG_P_CTRL_ADPT_MAX
- Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control adaptation lower than min. threshold ARTEON_CHG_P_CTRL_ADPT_LO_MIN
- Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control specified value ARTEON_CHG_P_CTRL_SPEC
- Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control valve activation pulse duty factor ARTEON_CHG_P_CTRL_VLV
- Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control valve position, actual value ARTEON_CHG_P_CTRL_VLV_POS_ACT
- Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control valve position, target value ARTEON_CHG_P_CTRL_VLV_POS_TGT
- Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Charge pressure control valve sensor voltage ARTEON_CHG_P_CTRL_VLV_SENS_V
- Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2017 to 2026.
Charge pressure control valve voltage, position closed ARTEON_CHG_P_CTRL_VLV_V_POS
- Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2017 to 2026.
Charge pressure control valve voltage, position opened ARTEON_CHG_P_CTRL_VLV_V_POS_OPENED
- Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2017 to 2026.
Charge pressure regulator, lower threshold adaptation ARTEON_CHG_P_REGULATOR_LO
- Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge pressure regulator, upper threshold adaptation ARTEON_CHG_P_REGULATOR_HI
- Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2017 to 2026.
Charge pressure sensor, unconditioned voltage ARTEON_CHG_P_SENS_V
- Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Control module voltage ARTEON_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x2FAF = 12207 → = 12.207 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2020 to 2021.
Cylinder charge specified value ARTEON_CYL_CHG_SPEC
- Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2017 to 2026.
Cylinder charge, actual value ARTEON_CYL_CHG_ACT
- Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2017 to 2026.
DC to DC converter high-voltage side voltage ARTEON_DCDC_HV_V
- Service 22
DID 1587 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2017 to 2026.
Ecall battery charge level ARTEON_ECALL_BATTERY_CHARGE_LEVELConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x56 = 86 → 86 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Ecall battery charge status ARTEON_ECALL_BATTERY_CHARGE_STATUSConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x02 = 2 → 2
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Generator voltage, actual ARTEON_GEN_V_ACT
- Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2017 to 2026.
High pressure exhaust gas recirculation actuator, actual unconditioned voltage ARTEON_HIGH_P_EGR_ACTUATOR_ACT_V
- Service 22
DID 11A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2017 to 2026.
High voltage battery energy information ARTEON_HIGH_V_EM_HVBAT
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2017 to 2026.
High voltage battery energy information ARTEON_HVBAT_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638 kWh
- Unit
- kWh
In testing for 2017 to 2026.
HV battery maximum power ARTEON_HVBAT_PWR_MAX
- Service 22
DID 1502 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262140 W
- Unit
- W
In testing for 2017 to 2026.
HV battery temperature load ARTEON_HVBAT_T_LOAD
- Service 22
DID 1165 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2017 to 2026.
Knock sensor voltage, cylinder 1 ARTEON_KNOCK_SENS_V_CYL_1
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor voltage, cylinder 3 ARTEON_KNOCK_SENS_V_CYL_3_7E0
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor voltage:, cylinder 2 ARTEON_KNOCK_SENS_V_CYL_2
- Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor voltage:, cylinder 3 ARTEON_KNOCK_SENS_V_CYL_3
- Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor voltage:, cylinder 5 ARTEON_KNOCK_SENS_V_CYL_5
- Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor voltage:, cylinder 6 ARTEON_KNOCK_SENS_V_CYL_6
- Service 22
DID 13FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensors average voltage bank 1, variant 2 ARTEON_KNOCK_SENSORS_AVG_V_1_2
- Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Onboard electrical system power ARTEON_AUX_PWR
- Service 22
DID 1077 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262140 W
- Unit
- W
In testing for 2017 to 2026.
Start/stop battery charge ARTEON_SSB_AHConfirmed
- Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
0x16 = 22 → 22 Ah
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery current ARTEON_SSB_CConfirmed
- Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- 0 to 100 A
- Unit
- A
0x00000000 = 0 → = 0 A
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery sensor temperature ARTEON_SSB_TConfirmed
- Service 22
DID 2A0B - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x47 = 71 → = 31 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery state of charge ARTEON_SSB_SOCConfirmed
- Service 22
DID 2A0C - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x3C = 60 → 60 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery target voltage ARTEON_SSB_VTConfirmed
- Service 22
DID 2A00 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
0x00 = 0 → = 10.6 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery total charge ARTEON_SSB_TOTAL_CHARGEConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 100 Ah
- Unit
- Ah
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery total discharge ARTEON_SSB_TOTAL_DISCHARGEConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 100 Ah
- Unit
- Ah
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery voltage ARTEON_SSB_VConfirmed
- Service 22
DID 2A07 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 4 to 69.535 V
- Unit
- V
0x1FA9 = 8105 → = 12.105 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Start/stop battery voltage ARTEON_SSB_V_RESTConfirmed
- Service 22
DID 2A10 - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 9 to 34.5 V
- Unit
- V
0x20 = 32 → = 12.2 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Temperature sensor for engine temperature management voltage ARTEON_T_SENS_ENG_T_V
- Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Turbocharger inlet pressure corrected value ARTEON_TURBOCHARGER_INLET_P
- Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Climate
A/C clutch ARTEON_AC_CLUTCHConfirmed
- Service 22
DID 482B - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021. In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020.
A/C compressor load ARTEON_AC_COMPRESSOR_LOADConfirmed
- Service 22
DID 2604 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 N·m
- Unit
- N·m
0x05 = 5 → = 0.5 N·m
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
A/C compressor speed ARTEON_AC_COMPRESSOR_SPEEDConfirmed
- Service 22
DID 2603 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Air pollution level ARTEON_AIR_POLUTIONConfirmed
0 means clean air.
- Service 22
DID 26ED - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -12.7 to 12.7
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2020.
Ambient air temperature ARTEON_AATConfirmed
- Service 22
DID 1014 - Module
714 → 77E - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x8D = 141 → = 20.5 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Ambient air temperature ARTEON_AAT_7E0_7E0
- Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Ambient temperature ARTEON_AAT_V2Confirmed
- Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255 to 255 °C
- Unit
- °C
0x09F7 = 2551 → = 19.929688 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Barometric pressure ARTEON_BARO
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Cabin temperature ARTEON_IAT_CABINConfirmed
- Service 22
DID 2613 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x013C = 316 → = 31.6 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front left deflector temperature ARTEON_FRONT_LEFT_DEFLECTOR_TConfirmed
- Service 22
DID 260C - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x5A = 90 → = 30 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front left temperature flap actual value ARTEON_FRONT_LEFT_T_FLAP_ACTUAL_VALUEConfirmed
- Service 22
DID 2622 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front right deflector temperature ARTEON_FRONT_RIGHT_DEFLECTOR_TConfirmed
- Service 22
DID 260D - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x5A = 90 → = 30 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front right temperature flap actual value ARTEON_FRONT_RIGHT_T_FLAP_ACTUAL_VALUEConfirmed
- Service 22
DID 2626 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Leg deflector temperature ARTEON_LEG_DEFLECTOR_TConfirmed
- Service 22
DID 2611 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x62 = 98 → = 32.666667 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Outside humidity ARTEON_HVAC_OUTSIDE_HUM
- Service 22
DID 27C3 - Module
746 → 7B0 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Outside temperature, from cabin ARTEON_AAT_FROMCABINConfirmed
- Service 22
DID 2609 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -64 to 63.5 °C
- Unit
- °C
0x8C = -116 → = -58 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Radiator fan actual duty ARTEON_RADIATOR_FAN_ACTUAL_DUTYConfirmed
- Service 22
DID 2606 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x19 = 25 → = 10 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Radiator fan commanded duty ARTEON_RADIATOR_FAN_COMMANDED_DUTYConfirmed
- Service 22
DID 2607 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Recirculation flap actual position ARTEON_MQB_RECIRC_FLAP_ACTConfirmed
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Recirculation flap fresh air threshold ARTEON_MQB_RECIRC_FLAP_FRESH_THRConfirmed
- Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0028 = 40 → 40
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Recirculation flap target position ARTEON_MQB_RECIRC_FLAP_TRGConfirmed
- Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0023 = 35 → 35
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Recirculation flap threshold ARTEON_MQB_RECIRC_FLAP_THRConfirmed
- Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00D2 = 210 → 210
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Refrigerant pressure ARTEON_REFRIGERANT_PRESSUREConfirmed
- Service 22
DID 2605 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 bar
- Unit
- bar
0x23 = 35 → = 7 bar
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Temperature after evaporator ARTEON_T_AFTER_EVAPORATORConfirmed
- Service 22
DID 2612 - Module
746 → 7B0 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -42.624 to 42.291 °C
- Unit
- °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Clocks
Time since engine start ARTEON_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0024 = 36 → 36 s
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021.
Accelerator pedal release detection threshold voltage ARTEON_APP_REDUCE_V
- Service 22
DID 1029 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
Brake booster low pressure, actual ARTEON_BRAKE_BOOSTER_LOW_P_ACT
- Service 22
DID 1490 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.9937
- Unit
- Raw value
In testing for 2017 to 2026.
Brake booster pressure ARTEON_BRAKE_BOOSTER_P
- Service 22
DID 11CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559
- Unit
- Raw value
In testing for 2017 to 2026.
Brake booster pressure ARTEON_PQ35_BRAKE_BOOSTER_PConfirmed
- Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
0x047E = 1150 → = 1.15 bar
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Brake booster raw pressure ARTEON_BRAKE_BOOSTER_RAW_P
- Service 22
DID 11D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2026.
Brake pedal position ARTEON_BRAKE_PEDAL_POS
- Service 22
DID 105D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Brake pressure ARTEON_BRAKE_P
- Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -543.8501 to 458.8288 bar
- Unit
- bar
In testing for 2017 to 2026.
Brake pressure ARTEON_BRAKE_P_7E0
- Service 22
DID 195D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Brake pressure ARTEON_MQB_TCM_BRAKE_PConfirmed
- Service 22
DID 3803 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x7C0B = 31755 → = 317.55 bar
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Brake system vacuum pump active ARTEON_BRAKE_SYSTEM_VACUUMConfirmed
- Service 22
DID 395E - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Downshift point adaptation voltage ARTEON_DOWNSHIFT_ADAPT_V
- Service 22
DID 1028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
Pressure in brake servo unit ARTEON_P_BRAKE_SERVO_UNIT
- Service 22
DID 2005 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375
- Unit
- Raw value
In testing for 2017 to 2026.
Requested brake torque, auxiliary system ARTEON_REQ_BRAKE_TQ
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Pedals
Accelerator pedal position sensor 1 ARTEON_APP_POS1Confirmed
- Service 22
DID 2061 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x02D3 = 723 → = 0.723 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Accelerator pedal position sensor 2 ARTEON_APP_POS2Confirmed
- Service 22
DID 2062 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x0169 = 361 → = 0.361 V
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Drivetrain
All-wheel drive current ARTEON_PQ35_HAL_IConfirmed
- Service 22
DID 2BE6 - Module
70F → 779 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
All-wheel drive duty cycle ARTEON_PQ35_HAL_DUTYConfirmed
- Service 22
DID 2BF3 - Module
70F → 779 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
All-wheel drive mode ARTEON_PQ35_HAL_MODEConfirmed
- Service 22
DID 0C0A - Module
70F → 779 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
All-wheel drive pulse width modulation ARTEON_PQ35_HAL_PWMConfirmed
- Service 22
DID 2BE7 - Module
70F → 779 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x35 = 53 → 53 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Driver torque requested #1 ARTEON_ENG_TRQ_REQ_1Confirmed
- Service 22
DID 29D4 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
0x0001 = 1 → = 0.1 N·m
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Driver torque requested #2 ARTEON_ENG_TRQ_REQ_2Confirmed
- Service 22
DID 4380 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
0x0005 = 5 → = 0.5 N·m
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared ARTEON_CLR_DISTConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0A5C = 2652 → 2,652 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020 to 2021.
Distance traveled while mil was activated ARTEON_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Number of warm-ups since diagnostic trouble codes cleared ARTEON_WARM_UPSConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xA3 = 163 → 163
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
ECU
Oil thermal wear ARTEON_OIL_THERMAL_WEARConfirmed
- Service 22
DID 224B - Module
714 → 77E - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x002E = 46 → 46 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Torque converter slip ARTEON_TORQUE_CONVERTER_SLIPConfirmed
- Service 22
DID 2131 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Engine
A/C compressor torque ARTEON_A_C_COMPRESSOR_TORQUE
- Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
A/C refrigerant pressure ARTEON_A_C_REFRIGERANT_PRES
- Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2017 to 2026.
Adaptation of loss torque ARTEON_ADPT_LOSS_TQ
- Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Adaptation of throttle valve ARTEON_ADPT_THROTTLE_VLV
- Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder1 fast diagnosis ARTEON_ADPT_VAL_CYL1_FAST
- Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder1 slow diagnosis ARTEON_ADPT_VAL_CYL1_SLOW
- Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder2 fast diagnosis ARTEON_ADPT_VAL_CYL2_FAST
- Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder2 slow diagnosis ARTEON_ADPT_VAL_CYL2_SLOW
- Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder3 fast diagnosis ARTEON_ADPT_VAL_CYL3_FAST
- Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder3 slow diagnosis ARTEON_ADPT_VAL_CYL3_SLOW
- Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder4 fast diagnosis ARTEON_ADPT_VAL_CYL4_FAST
- Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptation val.cylinder4 slow diagnosis ARTEON_ADPT_VAL_CYL4_SLOW
- Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2026.
Adaptive mode ARTEON_ADAPTIVE_MODE
- Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Air conditioning compressor pressure, linear raw value ARTEON_AC_COMP_P_LINEAR_RAW
- Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2017 to 2026.
Air conditioning compressor refrigerant pressure ARTEON_AC_COMP_REFRIGERANT_P
- Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2017 to 2026.
Air conditioning compressor torque ARTEON_AC_COMP_TQ
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Air conditioning compressor torque ARTEON_AC_COMP_TQ_REQ
- Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Air conditioning refrigerant pressure ARTEON_AC_REFRIGERANT_P
- Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2017 to 2026.
Air filling ARTEON_AIR_FILLING
- Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Air leakage ARTEON_AIR_LEAKAGE
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Air mass meter 1 ARTEON_MQB_AIR_MASS_1
- Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Air mass, actual value, mg/stroke ARTEON_AIR_MASS_ACT_MG
- Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2017 to 2026.
Ambient air pressure ARTEON_AMBIENT_AIR_P
- Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 2017 to 2026.
Ambient temperature ARTEON_AAT_7E0
- Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2017 to 2026.
Ambient temperature ARTEON_AAT_7E0_2
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Analysis, clutch 1, maximum temperature ARTEON_ANALYSIS_CLU_1_MAX_T
- Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2026.
Analysis, clutch 2, maximum temperature ARTEON_ANALYSIS_CLU_2_MAX_T
- Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2026.
Automatic engine starts counter ARTEON_AUTOMATIC_ENG_STARTS
- Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Automatic transmission fluid temperature, lifetime max ARTEON_ATF_MAXConfirmed
- Service 22
DID 704F - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x97 = 151 → = 101 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Aux. hydraulic pump internal temperature ARTEON_AUX_HYDRAULIC_PMP_T
- Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Aux. hydraulic pump, current ARTEON_AUX_HYDRAULIC_PMP
- Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 2017 to 2026.
Average ignition timing angle delay adjustment ARTEON_AVG_IGN_TIM_ANG
- Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Avg. injection time ARTEON_AVG_INJ_TIME_7E0
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2017 to 2026.
Basic correction factor:, cylinder 1, filtered ARTEON_BASIC_CORR_FACTOR_1
- Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2017 to 2026.
Basic correction factor:, cylinder 2, filtered ARTEON_BASIC_CORR_FACTOR_2
- Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2017 to 2026.
Basic correction factor:, cylinder 3, filtered ARTEON_BASIC_CORR_FACTOR_3
- Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2017 to 2026.
Basic correction factor:, cylinder 4, filtered ARTEON_BASIC_CORR_FACTOR_4
- Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2017 to 2026.
Boost pressure actuator, commanded duty ARTEON_BOOST_P_ACTUATOR_CMD
- Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.993 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Boost pressure, actual ARTEON_BOOST_P_ACT
- Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Boost pressure, actual ARTEON_BOOST_P_ACT_7E0
- Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242
- Unit
- Raw value
In testing for 2017 to 2026.
Boost pressure, target ARTEON_BOOST_P_TGT
- Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550
- Unit
- Raw value
In testing for 2017 to 2026.
Boost regulation duty, commanded value ARTEON_BOOST_REGULATION_CMD
- Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Boost regulator feedback ARTEON_BOOST_REGULATOR_FEEDBACKConfirmed
- Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Bypass valve high pressure turbine inlet, activation ARTEON_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Bypass valve high pressure turbine inlet, actual value ARTEON_BYPASS_VLV_HIGH_P_ACT
- Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Bypass valve high pressure turbine inlet, offset closed ARTEON_BYPASS_VLV_HIGH_P
- Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Bypass valve high pressure turbine inlet, offset open ARTEON_BYPASS_VLV_HIGH_P_TURBINE
- Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Bypass valve high pressure turbine inlet, target value ARTEON_BYPASS_VLV_HIGH_P_TGT
- Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Bze_q_elad ARTEON_BZE_Q_ELAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Bze_q_lad ARTEON_BZE_Q_LAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021.
Calculated oil temperature ARTEON_PQ35_CALCULATED_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x01 = 1 → = -39 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Camshaft adaptation exhaust bank 1, phase position ARTEON_CAM_ADPT_EXH_BANK_1_PHASE
- Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adaptation intake bank 1, phase position ARTEON_CAM_ADPT_INT_BANK_1_PHASE
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adaptation intake, phase position ARTEON_CAM_ADPT_INT_PHASE
- Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adaptation, counter due to knock ARTEON_CAM_ADPT_CNT_KNOCK
- Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Camshaft adaptation, intake deviation ARTEON_CAM_ADPT_INT_DEV
- Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment intake bank 1, activation % ARTEON_CAM_ADJ_INT_BANK_1
- Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Camshaft adjustment intake test bank 1 ARTEON_CAM_ADJ_INT_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Camshaft adjustment outlet test bank 1 ARTEON_CAM_ADJ_OUTLET_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Camshaft adjustment, exhaust bank 1, actual value ARTEON_CAM_ADJ_EXH_BANK_1_ACT
- Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, exhaust bank 1, specified value ARTEON_CAM_ADJ_EXH_BANK_1_SPEC
- Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, exhaust bank 2, actual value ARTEON_CAM_ADJ_EXH_BANK_2_ACT
- Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, exhaust bank 2, specified value ARTEON_CAM_ADJ_EXH_BANK_2_SPEC
- Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262 to 262 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, exhaust, actual value ARTEON_CAM_ADJ_EXH_ACTConfirmed
- Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2020. In testing for 2017 to 2019, 2021 to 2026.
Camshaft adjustment, exhaust, specified value ARTEON_CAM_ADJ_EXH_SPEC
- Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, intake bank 1, actual value ARTEON_CAM_ADJ_INT_BANK_1_ACT
- Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, intake bank 1, specified value ARTEON_CAM_ADJ_INT_BANK_1_SPEC
- Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, intake, actual value ARTEON_CAM_ADJ_INT_ACT
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft adjustment, intake, specified value ARTEON_CAM_ADJ_INT_SPEC
- Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Camshaft position, deviation from the base position ARTEON_CAM_POS_DEV_BASE_POS
- Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2017 to 2026.
Cat. converter oxygen storage capacity measured ARTEON_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Cat. temperature, bank 1 ARTEON_CAT_T_BANK_1
- Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2017 to 2026.
Cat. temperature, bank 2 ARTEON_CAT_T_BANK_2
- Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2017 to 2026.
Catalyst temperature, calculated ARTEON_CAT_T_CALCConfirmed
- Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 1225 °C
- Unit
- °C
0x6B = 107 → = 485 °C
Confirmed for 2020. In testing for 2017 to 2019, 2021 to 2026.
Chain elongation inlet, mileage at last adaptation ARTEON_CHAIN_ELONGATION_INLET
- Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Chain elongation outlet, mileage at last adaptation ARTEON_CHAIN_ELONGATION
- Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 ARTEON_CHAIN_ELONGATION_NO_VALID_1
- Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Chain elongation, no of valid initial values, intake bank 1 ARTEON_CHAIN_ELONGATION_NO_1
- Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Clutch center central plate temperature ARTEON_CLU_CENTER_CENTRAL_T
- Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2026.
Commanded crankshaft torque ARTEON_CMD_CRANK_TQ
- Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020 to 2021.
Compression test, cylinder 1 ARTEON_COMPRESSION_TEST_CYL_1
- Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Compression test, cylinder 2 ARTEON_COMPRESSION_TEST_CYL_2
- Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Compression test, cylinder 3 ARTEON_COMPRESSION_TEST_CYL_3
- Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Compression test, cylinder 4 ARTEON_COMPRESSION_TEST_CYL_4
- Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Control module temperature ARTEON_CTRL_MODULE_T
- Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant circulation pump, activation ARTEON_CLT_CIRCULATION_PMP_ACTIVATION
- Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant circulation pump, control ARTEON_CLT_CIRCULATION_PMP
- Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant fan 1 activation, $1117 ARTEON_CLT_FAN_1_ACTIVATION_1117
- Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Coolant fan 1, activation ARTEON_CLT_FAN_1_ACTIVATION
- Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant fan 1, activation ARTEON_COOLANT_FAN_1_ACTIVATION
- Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant fan 2, activation ARTEON_CLT_FAN_2_ACTIVATION
- Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant fan, requested by A/C ARTEON_CLT_FAN_REQ_AC
- Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Coolant shut-off valve, closed ARTEON_CLT_SHUT_OFF_VLV
- Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2017 to 2026.
Coolant temperature at engine outlet, calculated ARTEON_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at engine outlet, calculated ARTEON_ECT_ENG_OUTLET_CALC
- Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at engine start ARTEON_COOLANT_T_AT_ENGINE_START
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at engine start ARTEON_ECT_ENG_START
- Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet ARTEON_COOLANT_TConfirmed
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
0xEB6D = 60269 → = 5,753.8 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Coolant temperature at radiator outlet ARTEON_ECT_RADIATOR_OUTLET
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet 2 ARTEON_ECT_RAD_OUT_2
- Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet v.1 ARTEON_ECT_RADIATOR_OUTLET_V_1
- Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet, actual value ARTEON_ECT_RADIATOR_OUTLET_ACT
- Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet, actual value ARTEON_ECT_RADIATOR_OUTLET_ACT_7E0
- Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature at radiator outlet, specified value ARTEON_ECT_RADIATOR_OUTLET_SPEC
- Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature difference between engine and radiator ARTEON_ECT_DIFF_ENG
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature linear ARTEON_ECT_LINEAR
- Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature modeled value ARTEON_COOLANT_T_MODELED_VALUE
- Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature, maximum value ARTEON_ECT_MAX
- Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2017 to 2026.
Coolant temperature, minimum value ARTEON_ECT_MIN
- Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2017 to 2026.
Correction factor of oil temperature for engine protection ARTEON_CORR_FACTOR_OIL_T
- Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99
- Unit
- Number
In testing for 2017 to 2026.
Crankshaft rotation angle when closing the quantity control valve ARTEON_CRANK_ROT_ANG
- Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 0 ARTEON_CTR_MIS_DC_MMV_CYL_0
- Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 ARTEON_CTR_MIS_DC_MMV_CYL_1
- Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 ARTEON_CTR_MIS_DC_MMV_CYL_2
- Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Current N215 pressure control valve 1 ARTEON_CURRENT_N215_P_CTRL_1
- Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current N216 pressure control valve 2 ARTEON_CURRENT_N216_P_CTRL_2
- Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current N217 pressure control valve 3 ARTEON_CURRENT_N217_P_CTRL_3
- Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current N218 pressure control valve 4 ARTEON_CURRENT_N218_P_CTRL_4
- Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current N233 pressure control valve 5 ARTEON_CURRENT_N233_P_CTRL_5
- Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current solenoid ARTEON_CURRENT_SOLENOID
- Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Current type of driver counter ARTEON_CURRENT_TYPE_DRIVER
- Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Cylinder 1 internal torque ARTEON_CYL_1_INTERNAL_TQ
- Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Cylinder 2 internal torque ARTEON_CYL_2_INTERNAL_TQ
- Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Cylinder 3 internal torque ARTEON_CYL_3_INTERNAL_TQ
- Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Cylinder 4 internal torque ARTEON_CYL_4_INTERNAL_TQ
- Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Cylinder block temperature sensor ARTEON_CYL_BLOCK_T_SENS
- Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Cylinder head temperature ARTEON_CYL_HEAD_T
- Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2017 to 2026.
Desired torque raw ARTEON_DES_TQ_RAW
- Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Diesel particulate filter differential pressure variant 2 ARTEON_OIL_LEVEL_LAST_VALIDConfirmed
- Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
0x0CE0 = 3296 → 3,296
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Diesel particulate filter exhaust gas flow volume ARTEON_MQB_DPF_EXH_VOLConfirmed
- Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Number
0x4E4F = 20047 → = 2,004.7
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Direct injections counter ARTEON_DIRECT_INJECTIONS
- Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2026.
Drive motor current ARTEON_MOTOR_I
- Service 22
DID 147D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2017 to 2026.
Drive motor speed ARTEON_MOTOR_RPM_ECM
- Service 22
DID 149A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Drive motor torque ARTEON_MOTOR_TQ
- Service 22
DID 147F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -10922.666 to 10922.333 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Driving mode sensor, hall sensor a ARTEON_DRIVING_MODE_SENS
- Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Driving position ARTEON_DRIVING_POS
- Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Driving resistance index ARTEON_DRIVING_RES_INDEX
- Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2017 to 2026.
Dynamic average of ignition angle delay adjustment ARTEON_DYNAMIC_AVG_IGN_ANG
- Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Ea888b boost pressure control, adaptation value 0 ARTEON_EA888B_BOOST_P_CTRL_0
- Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2017 to 2026.
Ea888b boost pressure control, adaptation value 1 ARTEON_EA888B_BOOST_P_CTRL_1
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2017 to 2026.
Ea888b boost pressure control, adaptation value 2 ARTEON_EA888B_BOOST_P_CTRL_2
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2017 to 2026.
Ea888b boost pressure control, adaptation value 3 ARTEON_EA888B_BOOST_P_CTRL_3
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2017 to 2026.
Ea888b boost pressure regulator, commanded ARTEON_EA888B_BOOST_P_CMD
- Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Early ignition counter for toque reduction, cylinder 1 ARTEON_EARLY_IGN_CNT_TOQUE_1
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for toque reduction, cylinder 2 ARTEON_EARLY_IGN_CNT_TOQUE_2
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for toque reduction, cylinder 3 ARTEON_EARLY_IGN_CNT_TOQUE_3
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for toque reduction, cylinder 4 ARTEON_EARLY_IGN_CNT_TOQUE_4
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder 1 ARTEON_EARLY_IGN_CNT_CYL_1
- Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder 2 ARTEON_EARLY_IGN_CNT_CYL_2
- Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder 3 ARTEON_EARLY_IGN_CNT_CYL_3
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder 4 ARTEON_EARLY_IGN_CNT_CYL_4
- Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 1 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 2 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 3 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 4 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 1 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 2 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 3 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 4 ARTEON_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, total, cylinder 1 ARTEON_EARLY_IGN_CNT_TOT_1
- Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, total, cylinder 2 ARTEON_EARLY_IGN_CNT_TOT_2
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, total, cylinder 3 ARTEON_EARLY_IGN_CNT_TOT_3
- Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter, total, cylinder 4 ARTEON_EARLY_IGN_CNT_TOT_4
- Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Effective injection duration ARTEON_EFFECTIVE_INJ_DUR
- Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2017 to 2026.
EGT after catalyst, model bank b ARTEON_EGT_AFTER_CAT_MODEL_B
- Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2017 to 2026.
Electric additional coolant pump control, high circle ARTEON_ELEC_ADDITIONAL_CLT
- Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Energy balance of last driving cycle ARTEON_ENERGY_BALANCE_LAST
- Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Energy content ARTEON_ENERGY_CONTENT
- Service 22
DID 22E4 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Engine air mass, specified value ARTEON_ENG_AIR_MASS_SPEC
- Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2026.
Engine compartment temperature raw value ARTEON_ENG_COMPARTMENT_T
- Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine control module temperature ARTEON_ENG_CTRL_MODULE_TConfirmed
- Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x01D6 = 470 → = 47 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020 to 2021.
Engine drag torque ARTEON_ENG_DRAG_TQ
- Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Engine oil level ARTEON_ENG_OIL_LEVEL_7E0
- Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 2017 to 2026.
Engine oil level current value ARTEON_ENG_OIL_LEVEL
- Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine oil pressure ARTEON_EOP
- Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 157 psi
- Unit
- psi
In testing for 2017 to 2026.
Engine oil sump temperature ARTEON_ENG_OIL_SUMP_T
- Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2017 to 2026.
Engine oil temperature ARTEON_EOTConfirmed
- Service 22
DID 202F - Module
714 → 77E - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -58 to 197 °C
- Unit
- °C
0x9D = 157 → = 99 °C
Confirmed for 2020. In testing for 2017 to 2019, 2022 to 2026. Not supported for 2021.
Engine oil temperature ARTEON_EOT_7E0
- Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature ARTEON_EOT_7E0_7E0
- Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature measured value ARTEON_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature sensor 2 ARTEON_EOT_SENS_2
- Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, pulse sensor ARTEON_EOT_PULS
- Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine outlet coolant temperature calculated ARTEON_ENG_OUTLET_ECT_CALC
- Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine protection, torque limit ARTEON_ENG_PROTECTION_TQ
- Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Engine radiator fan request ARTEON_ENG_RADIATOR_FAN_REQ
- Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2021. Supported for 2020.
Engine temperature control actuator ARTEON_ENG_T_CTRL_ACTUATOR
- Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine temperature management actuator, after-run stop ARTEON_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Engine temperature management actuator, duty cycle activation ARTEON_ENG_T_MANAGEMENT_ACTUATOR
- Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine temperature management actuator, raw value ARTEON_ENG_T_MANAGEMENT
- Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Engine temperature management actuator, specified value ARTEON_ENG_T_MANAGEMENT_SPEC
- Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine temperature management actuator, stop open ARTEON_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Engine torque ARTEON_ENG_TQ
- Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Engine torque ARTEON_ENG_TQ_7E0
- Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Engine torque ARTEON_MQB_TCM_ENG_TORQUEConfirmed
- Service 22
DID 7064 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Engine torque limitation ARTEON_ENG_TQ_LIM
- Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Excessive temperature protection ARTEON_EXCESSIVE_T
- Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Exhaust camshaft, adaptation bias ARTEON_EXH_CAM_ADPT_BIAS
- Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2017 to 2026.
Exhaust camshaft, adaptation sensor tolerance ARTEON_EXH_CAM_ADPT_SENS
- Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2017 to 2026.
Exhaust gas jet volume in particle filter ARTEON_EXH_GAS_JET_VOLUME
- Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 L
- Unit
- L
In testing for 2017 to 2026.
Exhaust gas temperature ARTEON_EXH_GAS_T
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature - calculated after catalyst ARTEON_EXH_GAS_T_CALC_AFTER
- Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature before catalytic converter ARTEON_EXH_GAS_T_BEFORE
- Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature before the front catalytic converter, model value ARTEON_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature sensor 1 ARTEON_EXH_GAS_T_SENS_1
- Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature sensor 4 ARTEON_EXH_GAS_T_SENS_4
- Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust gas temperature, sensor 4, bank 2 ARTEON_EXH_GAS_T_S4_B2
- Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Exhaust temperature before the catalyst, modeled ARTEON_EXH_T_BEFORE_CAT
- Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2017 to 2026.
Generator current ARTEON_GEN_CURRENT
- Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2017 to 2026.
Generator load normalized value ARTEON_GENERATOR_LOAD_NORMALIZED_VALUE
- Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator load signal ARTEON_GEN_LOAD_SIG
- Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator load signal ARTEON_GEN_LOAD_SIG_7E0
- Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Generator load signal ARTEON_GENERATOR_LOAD_SIG
- Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator performance ARTEON_GENERATOR_PERFORMANCE
- Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 2017 to 2026.
Generator torque request ARTEON_GENERATOR_TORQUE_REQUEST
- Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Heater circulation pump, nominal value ARTEON_HEATER_CIRCULATION
- Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Heater for nozzles active ARTEON_HEATER_FOR_NOZZLES_ACTIVEConfirmed
- Service 22
DID 1945 - Module
70E → 778 - Every
2 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Heater support pump, specified value ARTEON_HEATER_SUPPORT_PMP_SPEC
- Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Height correction ARTEON_HEIGHT_CORR
- Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2017 to 2026.
High pressure control, adaptation ARTEON_HIGH_P_CTRL_ADPT
- Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2017 to 2026.
High pressure EGR actuator, activation ARTEON_HIGH_P_EGR_ACTUATOR
- Service 22
DID 1334 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
High pressure regulation, adaptation value ARTEON_HIGH_P_REGULATION
- Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
ID of current driving program ARTEON_ID_CURRENT_DRIVING
- Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
IGA_CYL_KNK, 0 ARTEON_IGA_CYL_KNK_0
- Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2017 to 2026.
IGA_CYL_KNK, 1 ARTEON_IGA_CYL_KNK_1
- Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2017 to 2026.
IGA_CYL_KNK, 2 ARTEON_IGA_CYL_KNK_2
- Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2017 to 2026.
IGA_CYL_KNK, 3 ARTEON_IGA_CYL_KNK_3
- Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2017 to 2026.
IGA_IGC, 0 ARTEON_IGA_IGC_0
- Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2017 to 2026.
IGA_IGC, 1 ARTEON_IGA_IGC_1
- Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2017 to 2026.
IGA_IGC, 2 ARTEON_IGA_IGC_2
- Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2017 to 2026.
IGA_IGC, 3 ARTEON_IGA_IGC_3
- Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2017 to 2026.
Ignition angle current cylinder, actual value ARTEON_IGN_ANG_CURRENT_CYL_ACT
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -25 to 25 °
- Unit
- °
In testing for 2017 to 2026.
Injection amount deviation cylinder 1 ARTEON_INJ_AMOUNT_DEV_CYL_1
- Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2017 to 2026.
Injection amount deviation cylinder 2 ARTEON_INJ_AMOUNT_DEV_CYL_2
- Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2017 to 2026.
Injection amount deviation cylinder 3 ARTEON_INJ_AMOUNT_DEV_CYL_3
- Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2017 to 2026.
Injection amount deviation cylinder 4 ARTEON_INJ_AMOUNT_DEV_CYL_4
- Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2017 to 2026.
Injection quantity deviation, cylinder 2 ARTEON_INJ_QTY_DEV_CYL_2
- Service 22
DID 204A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Injection quantity deviation, cylinder 5 ARTEON_INJ_QTY_DEV_CYL_5
- Service 22
DID 204B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Injector 2: rail pressure calibration point 1 ARTEON_INJ_2_RAIL_P_CAL_PT_1_146EConfirmed
- Service 22
DID 146E - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Injector 2: rail pressure calibration point 2 ARTEON_INJ_2_RAIL_P_CAL_PT_2_1474Confirmed
- Service 22
DID 1474 - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Injector 2: rail pressure calibration point 3 ARTEON_INJ_2_RAIL_P_CAL_PT_3_147AConfirmed
- Service 22
DID 147A - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Injector 7: rail pressure calibration point 1 ARTEON_INJ_7_RAIL_P_CAL_PT_1Confirmed
- Service 22
DID 146D - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x001A = 26 → = 1.3
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Injector 7: rail pressure calibration point 2 ARTEON_INJ_7_RAIL_P_CAL_PT_2Confirmed
- Service 22
DID 1473 - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Injector 7: rail pressure calibration point 3 ARTEON_INJ_7_RAIL_P_CAL_PT_3Confirmed
- Service 22
DID 1479 - Module
7E0 → 7E8 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Inlet flaps - actual value ARTEON_INLET_FLAPS_ACT
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Inlet flaps - requested value ARTEON_INLET_FLAPS_REQ
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Intake air temperature ARTEON_IAT_7E0
- Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2017 to 2026.
Intake air temperature before throttle valve, raw value ARTEON_IAT_BEFORE_THROTTLE
- Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2017 to 2026.
Intake air temperature in intake manifold ARTEON_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2017 to 2026.
Intake air temperature raw value ARTEON_IAT_RAW
- Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2017 to 2026.
Intake camshaft, adaptation bias ARTEON_INT_CAM_ADPT_BIAS
- Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2017 to 2026.
Intake camshaft, adaptation sensor tolerance ARTEON_INT_CAM_ADPT_SENS
- Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2017 to 2026.
Intake manifold pressure raw value ARTEON_INT_MANIFOLD_P_RAW
- Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2017 to 2026.
Intake manifold pressure, commanded ARTEON_INT_MANIFOLD_P_CMD
- Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Intake manifold pressure, corrected ARTEON_INT_MANIFOLD_P
- Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Intake manifold runner control, acknowledgment ARTEON_INT_MANIFOLD_RUNNER_CTRL
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Intake manifold runner control, activation ARTEON_INT_MANIFOLD_RUNNER
- Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Intake model air mass flow filtered value ARTEON_INT_MODEL_AIR_MASS
- Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Intake phase deviation, actual value ARTEON_INT_PHASE_DEV_ACT
- Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2017 to 2026.
Integrated mass of air since engine start ARTEON_INTEGRATED_MASS_AIR
- Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2017 to 2026.
Integrated mass of air since the first engine start ARTEON_INTEGRATED_MASS_AIR_SINCE
- Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2017 to 2026.
Kick down ARTEON_MQB_TCM_KICK_DOWNConfirmed
- Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Knock sensor 1 test ARTEON_KNOCK_SENS_1_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Knock sensor 2 test ARTEON_KNOCK_SENS_2_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Knock sensor 3 test ARTEON_KNOCK_SENS_3_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Knock sensor 4 test ARTEON_KNOCK_SENS_4_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Knock sensor, cylinder 1 ARTEON_KNOCK_SENS_CYL_1
- Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor, cylinder 1 ARTEON_KNOCK_SNS_C1_V_MS
- Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2017 to 2026.
Knock sensor, cylinder 2 ARTEON_KNOCK_SENS_CYL_2
- Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor, cylinder 2 ARTEON_KNOCK_SENS_CYL_2_7E0
- Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3272
- Unit
- Number
In testing for 2017 to 2026.
Knock sensor, cylinder 2 ARTEON_KNOCK_SNS_C2_V_MS
- Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2017 to 2026.
Knock sensor, cylinder 3 ARTEON_KNOCK_SENS_CYL_3
- Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor, cylinder 3 ARTEON_KNOCK_SNS_C3_V_MS
- Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2017 to 2026.
Knock sensor, cylinder 4 ARTEON_KNOCK_SENS_CYL_4
- Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Knock sensor, cylinder 4 ARTEON_KNOCK_SNS_C4_V_MS
- Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2017 to 2026.
Lambda output value ARTEON_LAMBDA_OUTPUT
- Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2017 to 2026.
Launch control counter, variant 1 ARTEON_LAUNCH_CTRL_CNT_VAR_1
- Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Launch control counter, variant 2 ARTEON_LAUNCH_CTRL_CNT_VAR_2
- Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Long term fuel trim at idle, direct injection ARTEON_LONG_TERM_FUEL_TRIM_IDLE
- Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Long term fuel trim at idle, port injection ARTEON_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Long-term adaptation of intake manifold injection ARTEON_LONG_TERM_ADPT_INT
- Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Long-term adaptation of intake manifold injection at idle ARTEON_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Lost torque adaptation A/C + driving mode ARTEON_LOST_TQ_ADPT_AC
- Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Lost torque adaptation driving mode ARTEON_LOST_TQ_ADPT_DRIVING
- Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Low pressure EGR closing ARTEON_LOW_P_EGR_CLOSING
- Service 22
DID 17F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -699 to 100 %
- Unit
- %
In testing for 2017 to 2026.
M009, desired solenoid out 10 ARTEON_M009_DES_SOLENOID_10
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
M009, desired solenoid out 11 ARTEON_M009_DES_SOLENOID_11
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
M009, desired solenoid out 12 ARTEON_M009_DES_SOLENOID_12
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
M009, desired solenoid out 13 ARTEON_M009_DES_SOLENOID_13
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
M009, desired solenoid out 14 ARTEON_M009_DES_SOLENOID_14
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Main cat oxygen storage capacity age correction factor ARTEON_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2017 to 2026.
Manifold absolute pressure, raw value ARTEON_MAP_RAW
- Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Manual engine starts counter ARTEON_MANUAL_ENG_STARTS
- Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Mass air flow over throttle valve ARTEON_MAF_OVER_THROTTLE
- Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2026.
Mass air flow rate ARTEON_MAF_RATE
- Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2017 to 2026.
Mass air flow through throttle ARTEON_MAF_THROUGH_THROTTLE
- Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Mass air flow, commanded ARTEON_MAF_CMD
- Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Mass flow through throttle valve ARTEON_MASS_FLOW_THROUGH
- Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2017 to 2026.
Max permissible engine torque ARTEON_MAX_PERMISSIBLE_ENG
- Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Maximum ECU temperature ARTEON_MAX_ECU_T
- Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2017 to 2026.
Maximum filling correction factor from knock control ARTEON_MAX_FILLING_CORR
- Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96
- Unit
- Number
In testing for 2017 to 2026.
Maximum oil level for the service interval ARTEON_MAX_OIL_LEVEL
- Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2017 to 2026.
Mean engine air mass ARTEON_MEAN_ENG_AIR_MASS
- Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2026.
Mean injection quantity ARTEON_MEAN_INJ_QTY
- Service 22
DID 2097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2026.
Mean injection quantity ARTEON_MEAN_INJ_QUANTITYConfirmed
- Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
0xEDA1 = -4703 → = -47.03
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Mileage with ECU installed ARTEON_MILEAGE_ECU
- Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2017 to 2026.
Minimum oil level for the service interval ARTEON_MIN_OIL_LEVEL
- Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2017 to 2026.
Misfires counter:, cylinder 1 ARTEON_MIS_CNT_1
- Service 22
DID 147E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires counter:, cylinder 2 ARTEON_MIS_CNT_2
- Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires counter:, cylinder 3 ARTEON_MIS_CNT_3
- Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires counter:, cylinder 5 ARTEON_MIS_CNT_5
- Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires counter:, cylinder 6 ARTEON_MIS_CNT_6
- Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection ARTEON_MIS_PER_1000_1
- Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 2 ARTEON_MIS_PER_1000_2_7E0
- Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection ARTEON_MIS_PER_1000_2
- Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 3 ARTEON_MIS_PER_1000_3_7E0
- Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection ARTEON_MIS_PER_1000_3
- Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection ARTEON_MIS_PER_1000_4
- Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires total ARTEON_MIS_TOT
- Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 1 ARTEON_MIS_1
- Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 1 ARTEON_MISFIRES_C1_7E0
- Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 2 ARTEON_MIS_2
- Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 2 ARTEON_MISFIRES_C2
- Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 3 ARTEON_MIS_3
- Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 3 ARTEON_MISFIRES_C3_7E0
- Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 4 ARTEON_MIS_4
- Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 4 ARTEON_MISFIRES_C4
- Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Mixture adaptation factor at partial load ARTEON_MIXTURE_ADPT_FACTOR
- Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
N_32 ARTEON_N_32
- Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2017 to 2026.
NL_PRE, 0 ARTEON_NL_PRE_0
- Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2017 to 2026.
NL_PRE, 1 ARTEON_NL_PRE_1
- Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2017 to 2026.
NL_PRE, 2 ARTEON_NL_PRE_2
- Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2017 to 2026.
NL_PRE, 3 ARTEON_NL_PRE_3
- Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2017 to 2026.
Number of injections ARTEON_NUM_INJECTIONS
- Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded ARTEON_NUM_TIMES_PERMITTED_T
- Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Number of warnings due to increased centrifugal oil temperature ARTEON_NUM_WARN_HI_CENTRIF_T
- Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
NV energy requirement ARTEON_NV_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Oil ash limit ARTEON_OIL_ASH_LIM
- Service 22
DID 1793 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Oil ash residue ARTEON_OIL_ASH_RESIDUE
- Service 22
DID 208A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1310
- Unit
- Raw value
In testing for 2017 to 2026.
Oil fill level ARTEON_PQ35_OIL_FILL_LEVELConfirmed
- Service 22
DID 2006 - Module
7E0 → 7E8 - Every
30 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
0x0006 = 6 → = 0.36 mm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Oil level method 1 ARTEON_OIL_LEVEL_METHOD_1
- Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2017 to 2026.
Oil level method 2 ARTEON_OIL_LEVEL_METHOD_2
- Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2017 to 2026.
Oil level method 3 ARTEON_OIL_LEVEL_METHOD_3
- Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2017 to 2026.
Oil level test method 1 ARTEON_OIL_LEVEL_TEST_1
- Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Oil level test method 2 ARTEON_OIL_LEVEL_TEST_2
- Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Oil level test method 3 ARTEON_OIL_LEVEL_TEST_3
- Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Oil level, average dynamic value ARTEON_OIL_LEVEL_AVG
- Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2017 to 2026.
Oil level, static measured ARTEON_OIL_LEVEL_STATIC
- Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2017 to 2026.
Oil level, static measurement ARTEON_OIL_LEVEL_STATIC_7E0
- Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2017 to 2026.
Oil p ARTEON_OIL_P
- Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Oil pressure control valve activation pulse duty factor ARTEON_OIL_P_CTRL_VLV
- Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Oil pressure control valve, activation pulse duty factor ARTEON_OIL_P_CTRL_VLV_ACTIVATION
- Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Oil pressure sensor raw value ARTEON_OIL_P_SENS_RAW
- Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status ARTEON_OIL_P_SENS_PISTON
- Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure sensor, raw value ARTEON_OIL_P_SENS_RAW_7E0
- Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure switch activation, high pressure ARTEON_OIL_P_SWITCH_P
- Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure switch for high pressure, closed ARTEON_OIL_P_SWITCH_HIGH_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Oil pressure switch for low pressure, closed ARTEON_OIL_P_SWITCH_LOW_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Oil pressure switch for piston-cooling jets, closed ARTEON_OIL_P_SWITCH_PISTON
- Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure switch valve activation ARTEON_OIL_P_SWITCH_VLV
- Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure target ARTEON_OIL_P_TGT
- Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Oil pressure target ARTEON_OIL_P_TGT_7E0
- Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Oil pressure valve for piston cooling nozzles, control switch button ratio ARTEON_OIL_P_VLV_PISTON
- Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Oil pressure valve switch, control ARTEON_OIL_P_VLV_SWITCH
- Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure, actual value ARTEON_OIL_P_ACT_7E0
- Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Oil pressure, actual value ARTEON_OIL_P_ACT_7E0_2
- Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Oil pressure, actual value ARTEON_OIL_P_ACT_7E0_2_7E0
- Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Oil temperature ARTEON_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Oil warning threshold ARTEON_OIL_WARN_THR
- Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 2017 to 2026.
Open cam shaft angle at quantity control valve ARTEON_OPEN_CAM_SHFT_ANG
- Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2017 to 2026.
Outside temperature ARTEON_OUTSIDE_T
- Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Outside temperature, system calculated ARTEON_OUTSIDE_T_SYSTEMConfirmed
- Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x8B = 139 → = 19.5 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Overall energy balance ARTEON_OVERALL_ENERGY
- Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Oxygen control, adaptation value at part. load ARTEON_OXYGEN_CTRL_ADPT
- Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature ARTEON_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2017 to 2026.
Particle sensor, time in op.mode measurement ARTEON_PARTICLE_SENS_TIME
- Service 22
DID 46D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2017 to 2026.
Particulate filter surface temperature ARTEON_DPF_SFC_TConfirmed
- Service 22
DID 1044 - Module
7E0 - Every
300 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
0x7FFF = 32767 → = 3,003.6 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Pilot injection 1, activation start ARTEON_PRE_INJ_1_ACTIVATION
- Service 22
DID 12C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2017 to 2026.
Pilot injection 2, activation start ARTEON_PRE_INJ_2_ACTIVATION
- Service 22
DID 12C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2017 to 2026.
Pilot injection 3 start ARTEON_PRE_INJ_3_START
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2017 to 2026.
Pilot injection 3, activation duration ARTEON_PRE_INJ_3_ACTIVATION
- Service 22
DID 121A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2017 to 2026.
Pilot injection 3, activation start ARTEON_PRE_INJ_3_ACTIVATION_START
- Service 22
DID 121D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2017 to 2026.
Piston cooling nozzles, control ARTEON_PISTON_COOLING
- Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Piston-cooling jets, activation ARTEON_PISTON_COOLING_JETS
- Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Port injection injections counter ARTEON_PORT_INJ_INJECTIONS
- Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2026.
Post injection 1 ARTEON_POST_INJ_1
- Service 22
DID 081A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Post injection 1 ARTEON_POST_INJ_1_7E0
- Service 22
DID 205D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2017 to 2026.
Post injection 2 ARTEON_POST_INJ_2
- Service 22
DID 080C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Post injection 2 ARTEON_POST_INJ_2_7E0_7E0
- Service 22
DID 205F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2017 to 2026.
Post injection 3 ARTEON_POST_INJ_3
- Service 22
DID 081B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2017 to 2026.
Post injection 3 ARTEON_POST_INJ_3_7E0
- Service 22
DID 20C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2017 to 2026.
Post-injection 1 duration ARTEON_PQ35_POST_INJ_1_DURATION
- Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Post-injection 2, activation duration ARTEON_POST_INJ_2_7E0
- Service 22
DID 121B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2017 to 2026.
Pressure before throttle valve - actual value ARTEON_P_BEFORE_THROTTLE_ACT
- Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2017 to 2026.
Pressure before throttle valve - sensor measured ARTEON_P_BEFORE_THROTTLE
- Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2017 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 ARTEON_PSN_EDGE_REL_AD_CAM_1
- Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2017 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 ARTEON_PSN_EDGE_REL_AD_CAM_2
- Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2017 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 ARTEON_PSN_EDGE_REL_AD_CAM_SAVE_1
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2017 to 2026.
Radiator fan 1, commanded duty ARTEON_RADIATOR_FAN_1_CMD
- Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Radiator fan 2, commanded duty ARTEON_RADIATOR_FAN_2_CMD
- Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2017 to 2026.
Rated drive torque ARTEON_RATED_DRIVE_TQ
- Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Rear cat converter temperature, main catalytic converter model value ARTEON_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear deflector temperature ARTEON_CLIMATE_RR_DEFL_TConfirmed
- Service 22
DID 263D - Module
746 → 7B0 - Every
5 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x35 = 53 → = 17.666667 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Reducing agent tank volume, act. value filtered ARTEON_REDUCING_AGENT_TANK_ACT
- Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 L
- Unit
- L
In testing for 2017 to 2026.
Relative load value ARTEON_REL_LOAD
- Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 2017 to 2026.
Relay for reserve coolant pump status ARTEON_RELAY_RESERVE_CLT
- Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Requested torque, amount for auxiliary units ARTEON_REQ_TQ_AMOUNT
- Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Reserve torque ARTEON_RESERVE_TQ
- Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Result of crankcase ventilation test, fail ARTEON_RESULT_CRANKCASE_VENTILATION_TEST
- Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Result of crankcase ventilation test, successful ARTEON_RESULT_CRANKCASE
- Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Route data, active ARTEON_ROUTE_DATA_ACTIVE
- Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Secondary air injection sensor 1 ARTEON_SECONDARY_AIR_INJ_1
- Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2017 to 2026.
SEG_AD_MMV_ER_H, 0 ARTEON_SEG_AD_MMV_ER_H_0
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_H, 2 ARTEON_SEG_AD_MMV_ER_H_2
- Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_H, 3 ARTEON_SEG_AD_MMV_ER_H_3
- Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_L, 0 ARTEON_SEG_AD_MMV_ER_L_0
- Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_L, 2 ARTEON_SEG_AD_MMV_ER_L_2
- Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_L, 3 ARTEON_SEG_AD_MMV_ER_L_3
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_MID, 0 ARTEON_SEG_AD_MMV_ER_MID_0
- Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_MID, 1 ARTEON_SEG_AD_MMV_ER_MID_1
- Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER_MID, 2 ARTEON_SEG_AD_MMV_ER_MID_2
- Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER, 1 ARTEON_SEG_AD_MMV_ER_1
- Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER, 2 ARTEON_SEG_AD_MMV_ER_2
- Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
SEG_AD_MMV_ER, 3 ARTEON_SEG_AD_MMV_ER_3
- Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2017 to 2026.
Sensor for particle filter differential pressure, raw value ARTEON_SENS_PARTICLE_FLT_P
- Service 22
DID 39E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Service limit ARTEON_SERVICE_LIM
- Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2017 to 2026.
Service limit ARTEON_SERVICE_LIM_7E0
- Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2017 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020 to 2021.
SIM card, SIM card in main unit ARTEON_SIM_CARD_SIM_CARD
- Service 22
DID 1814 - Module
773 → 7DD - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Spark efficiency deviation at idle, maximum ARTEON_SPARK_EFFICIENCY_DEV_MAX
- Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Spark efficiency deviation at part load, maximum ARTEON_SPARK_EFFICIENCY_DEV_PART_MAX
- Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Stop signal switch ARTEON_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed
- Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Sum of misfires counter ARTEON_SUM_MIS_CNT
- Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Tank fill level diagnostic reference value ARTEON_TANK_FILL_LEVEL
- Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2017 to 2026.
TCO_1_ST ARTEON_TCO_1_ST
- Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
TCO_1_SYS ARTEON_TCO_1_SYS
- Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Temperature at air conditioner heat exchanger output ARTEON_T_AC_HEAT_EXCHANGER
- Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Temperature sensor for engine temperature management ARTEON_T_SENS_ENG_T
- Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Temperature sensor for engine temperature management, target value ARTEON_T_SENS_ENG_T_TGT
- Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Test of catalytic converter status, canceled ARTEON_TEST_CATALYTIC_CONV_STAT
- Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Test of catalytic converter, measured value ARTEON_TEST_CATALYTIC_CONV
- Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Number
In testing for 2017 to 2026.
Thermostat, actual ARTEON_THERMOSTAT_ACT
- Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Thermostat, commanded ARTEON_THERMOSTAT_CMD
- Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Throttle regulator nominal value ARTEON_THROTTLE_REGULATOR
- Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
TI_1_MPI, 0 ARTEON_TI_1_MPI_0
- Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_1_MPI, 1 ARTEON_TI_1_MPI_1
- Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_1_MPI, 2 ARTEON_TI_1_MPI_2
- Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_1_MPI, 3 ARTEON_TI_1_MPI_3
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_1, 1 ARTEON_TI_MES4_PLS_1_1
- Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_1, 2 ARTEON_TI_MES4_PLS_1_2
- Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_1, 3 ARTEON_TI_MES4_PLS_1_3
- Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_2, 0 ARTEON_TI_MES4_PLS_2_0
- Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_2, 1 ARTEON_TI_MES4_PLS_2_1
- Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_2, 2 ARTEON_TI_MES4_PLS_2_2
- Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_2, 3 ARTEON_TI_MES4_PLS_2_3
- Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_3, 0 ARTEON_TI_MES4_PLS_3_0
- Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_3, 1 ARTEON_TI_MES4_PLS_3_1
- Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_3, 2 ARTEON_TI_MES4_PLS_3_2
- Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
TI_MES4_PLS_3, 3 ARTEON_TI_MES4_PLS_3_3
- Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2017 to 2026.
Time in after-run ARTEON_TIME_AFTERRUN
- Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2026.
Time since reset ARTEON_TIME_SINCE_RESET
- Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2017 to 2026.
Timing angle retardation cylinder 1 ARTEON_PQ35_TIMING_ANGLE_RETARDATION_CYL_1Confirmed
- Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
0x00 = 0 → = -48 °
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Timing angle retardation cylinder 2 ARTEON_PQ35_TIMING_ANGLE_RETARDATION_CYL_2Confirmed
- Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
0x00 = 0 → = -48 °
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Timing angle retardation cylinder 3 ARTEON_PQ35_TIMING_ANGLE_RETARDATION_CYL_3Confirmed
- Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
0x00 = 0 → = -48 °
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Timing angle retardation cylinder 4 ARTEON_PQ35_TIMING_ANGLE_RETARDATION_CYL_4Confirmed
- Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
0x00 = 0 → = -48 °
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Timing deviation after chain replacement, exhaust bank 1 ARTEON_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Timing deviation after chain replacement, intake bank 1 ARTEON_TIM_DEV_AFTER_CHAIN_1
- Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Timing deviation after other repairs, intake bank 1 ARTEON_TIM_DEV_AFTER_OTHER_1
- Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Timing deviation after other repairs, intake bank 1 ARTEON_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Timing deviation current value exhaust bank 1 ARTEON_TIM_DEV_CURRENT_EXH_1
- Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Timing deviation current value intake bank 1 ARTEON_TIM_DEV_CURRENT_INT_1
- Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2017 to 2026.
Torque converter: torque loss ARTEON_TORQUE_CONVERTER_TORQUE_LOSS
- Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque factor ARTEON_TQ_FACTOR
- Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Torque increase request from ESP ARTEON_TQ_INCREASE_REQ_ESP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque limitation ARTEON_TORQUE_LIMITATION
- Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque limitation ARTEON_TQ_LIM
- Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque limitation ARTEON_TQ_LIM_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque limitation, clutch protection ARTEON_TQ_LIM_CLU
- Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque loss adaptation ARTEON_TQ_LOSS_ADPT
- Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque loss adaptation at idle ARTEON_TQ_LOSS_ADPT_IDLE
- Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque loss adaptation, A/C compressor ARTEON_TQ_LOSS_ADPT_AC_COMP_7E0
- Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque reduction request from ESP ARTEON_TQ_REDUCTION_REQ_ESP
- Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque request, sum of auxiliary aggregate ARTEON_TQ_REQ_SUM_AUXILIARY
- Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque transmitting function, ratio ARTEON_TQ_TRANSMITTING
- Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2017 to 2026.
Total mass of gasoline and ethyl alcohol in oil ARTEON_TOT_MASS_GASOLINE
- Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 2017 to 2026.
Transmission drag torque ARTEON_TCM_DRAG_TQ
- Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Transmission fluid temperature, calculated ARTEON_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission fluid temperature, modeled maximum reached ARTEON_ATF_T_MODELED_MAX_REACHED
- Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission torque losses ARTEON_TCM_TQ_LOSSES
- Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Turbine actuator 1 bank 1 activation ARTEON_PQ35_TURB_ACT_1_B1Confirmed
- Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0002 = 2 → = 0.02 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Turbine actuator 1 bank 1: activation ARTEON_ACTConfirmed
- Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Valve lift system, result of last switch, intake ARTEON_VLV_LIFT_SYSTEM
- Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Valve lift system, valve lift, exhaust ARTEON_VLV_LIFT_SYSTEM_VLV_LIFT
- Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Valve lift system, valve lift, intake ARTEON_VLV_LIFT_SYSTEM_VLV
- Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Valve timing, the difference between the, actual and the set angle ARTEON_VLV_TIM_DIFF_ACT_SET
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 2017 to 2026.
Variable valve timing, intake, bank 1, regulation ARTEON_VARIABLE_VLV_TIM_INT_1
- Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Variable valve timing, intake, bank 1, switch on ARTEON_VARIABLE_VLV_TIM_INT_1_ON
- Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Wear index %, 0=new engine ARTEON_WEAR_INDEX_0_NEW_ENG
- Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020 to 2021.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2020 to 2021.
Fluids
Automatic transmission fluid temperature ARTEON_ATF_TConfirmed
- Service 22
DID 2104 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x4E = 78 → = 38 °C
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Fuel
Activation of fuel pump electronics ARTEON_ACTIVATION_FUEL_PMP
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Counter of fuel entry in oil ARTEON_CNT_FUEL_ENTRY_OIL
- Service 22
DID 399F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Error counter bad fuel ARTEON_ERROR_CNT_BAD_FUEL
- Service 22
DID 44BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2026.
Fuel consumption ARTEON_FUEL_CONSConfirmed
- Service 22
DID 113F - Module
7E0 → 7E8 - Every
30 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
0xEC52 = 60498 → = 604.98 L
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Fuel consumption - actual drive cycle ARTEON_FUEL_CONS_ACT_DRIVE
- Service 22
DID 1519 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2017 to 2026.
Fuel consumption per driving cycle ARTEON_FUEL_CONS_PER
- Service 22
DID 51D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2017 to 2026.
Fuel flow ARTEON_FUEL_FLOW
- Service 22
DID 10A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 L
- Unit
- L
In testing for 2017 to 2026.
Fuel high pressure, actual value ARTEON_FUEL_HIGH_P_ACT
- Service 22
DID 2027 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2017 to 2026.
Fuel high pressure, control deviation ARTEON_FUEL_HIGH_P_CTRL_DEV
- Service 22
DID 20BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 bar
- Unit
- bar
In testing for 2017 to 2026.
Fuel high pressure, specified value ARTEON_FUEL_HIGH_P_SPEC
- Service 22
DID 293B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2017 to 2026.
Fuel injector time deviation, cylinder 1 ARTEON_FUEL_INJ_TIME_DEV_1
- Service 22
DID 2000 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel injector time deviation, cylinder 2 ARTEON_FUEL_INJ_TIME_DEV_2
- Service 22
DID 207B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel injector time deviation, cylinder 2 ARTEON_FUEL_INJ_TIME_DEV_CYL_2
- Service 22
DID 21C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel injector time deviation, cylinder 3 ARTEON_FUEL_INJ_TIME_DEV_3
- Service 22
DID 2100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel injector time deviation, cylinder 4 ARTEON_FUEL_INJ_TIME_DEV_4
- Service 22
DID 2101 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel level ARTEON_FLI_7E0
- Service 22
DID 1008 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
Fuel level ARTEON_PQ35_FUEL_LEVEL_7E0_2206Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 2206 - Module
7E0 → 7E8 - Every
30 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
0x08 = 8 → 8 L
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Fuel level input % ARTEON_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Fuel low pressure, actual value ARTEON_FUEL_LOW_P_ACT
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2017 to 2026.
Fuel low pressure, specified value ARTEON_FUEL_LOW_P_SPEC
- Service 22
DID 2932 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2017 to 2026.
Fuel mass request, integral controller ARTEON_FUEL_MASS_REQ_I_CTL
- Service 22
DID 130D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel mass request, proportional controller ARTEON_FUEL_MASS_REQ_P_CTL
- Service 22
DID 1312 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2017 to 2026.
Fuel metering valve ARTEON_FUEL_METERING_VLV
- Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Fuel mix correction coefficient ARTEON_FUEL_MIX_CORR
- Service 22
DID 1710 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to -73.1003
- Unit
- Number
In testing for 2017 to 2026.
Fuel part from EVAP system ARTEON_FUEL_PART_EVAP
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -0.9996 to 0.9918
- Unit
- Number
In testing for 2017 to 2026.
Fuel pressure regulator valve: specified value rail pressure ARTEON_SPEC_VALUE_RAIL_PConfirmed
- Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
0x0ABE = 2750 → = 275,000
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Fuel pressure, low actual ARTEON_FUEL_P_LOW_ACT
- Service 22
DID 1AB8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Fuel pump adaptation ARTEON_FUEL_PMP_ADPT
- Service 22
DID 11C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Fuel pump specified value ARTEON_FUEL_PMP_SPEC
- Service 22
DID 1109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Fuel pump, commanded duty ARTEON_FUEL_PMP_CMD_DUTY
- Service 22
DID 11A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.998 %
- Unit
- %
In testing for 2017 to 2026.
Fuel rate ARTEON_FUEL_RATE
- Service 22
DID 204C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2017 to 2026.
Fuel rate difference, injector/sensor ARTEON_FUEL_RATE_DIFF_INJ
- Service 22
DID 180A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127.9983 to 127.9944 L
- Unit
- L
In testing for 2017 to 2026.
Fuel tank fill level ARTEON_FUEL_TANK_FILL_LEVEL
- Service 22
DID 24FC - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2017 to 2026.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021.
Fuel temperature ARTEON_FUEL_T_7E0
- Service 22
DID 203E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Fuel temperature ARTEON_FUEL_T_7E0_2
- Service 22
DID 111C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2026.
Fuel volume ARTEON_FLI_VOL
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 22B0 - Module
714 → 77E - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
High fuel pressure control deviation ARTEON_HIGH_FUEL_P_CONTROL_DEVIATIONConfirmed
- Service 22
DID 121F - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
0x1870 = 6256 → = 625,600
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
High fuel pressure, actual ARTEON_HIGH_FUEL_P_ACT
- Service 22
DID 159F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2017 to 2026.
High fuel pressure, actual value ARTEON_HIGH_FUEL_P_ACT_7E0
- Service 22
DID 4460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2017 to 2026.
High fuel pressure, commanded ARTEON_HIGH_FUEL_P_CMD
- Service 22
DID 11D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2017 to 2026.
High fuel pressure, regulation error ARTEON_HIGH_FUEL_P
- Service 22
DID 11D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2017 to 2026.
High fuel pressure, target ARTEON_HIGH_FUEL_P_TGT
- Service 22
DID 111B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2017 to 2026.
Long term fuel trim at idle ARTEON_LONG_TERM_FUEL_TRIM_7E0
- Service 22
DID 110E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 %
- Unit
- %
In testing for 2017 to 2026.
Long term fuel trim at idle ARTEON_LONG_TERM_FUEL_TRIM_IDLE_7E0
- Service 22
DID 4381 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2026.
Long term fuel trim bank 1 ARTEON_LONG_TERM_FUEL_TRIM_1
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2017 to 2026.
Long term fuel trim direct injection at load ARTEON_LONG_TERM_FUEL_TRIM
- Service 22
DID 1779 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2017 to 2026.
Long term fuel trim port injection at load ARTEON_LONG_TERM_FUEL_TRIM_PORT
- Service 22
DID 177B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2017 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual ARTEON_RAT_EVAPORATED_FUEL_ACT
- Service 22
DID 1711 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.9915
- Unit
- Number
In testing for 2017 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum ARTEON_RAT_EVAPORATED_FUEL_MAX
- Service 22
DID 1712 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.992
- Unit
- Number
In testing for 2017 to 2026.
Short term fuel trim bank 1 ARTEON_SHORT_TERM_FUEL_TRIM_1
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2017 to 2026.
GPS
Satellites, tracked ARTEON_GPS_SATS_TRACKEDConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x0A = 10 → 10
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Satellites, visible ARTEON_GPS_SATS_VISIBLEConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Movement
Acceleration ARTEON_ACCEL
- Service 22
DID 2116 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Acceleration ARTEON_ACCEL_7E0
- Service 22
DID 10CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Acceleration ARTEON_ACCELERATIONConfirmed
- Service 22
DID 1187 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
0xFFF1 = -15 → = -0.015 m/s²
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Acceleration ARTEON_ACCELERATION_29BIT
- Service 22
DID 12B0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Acceleration or deceleration mode ARTEON_ACCEL_DECCELERATION
- Service 22
DID 2118 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Accelerator pedal position ARTEON_ACCEL_PEDAL_POS
- Service 22
DID 3804 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Accelerator pedal position ARTEON_ACCEL_PEDAL_POS_7E1
- Service 22
DID F449 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Accelerator pedal position 1 ARTEON_ACCEL_PEDAL_POS_1
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Accelerator pedal position 2 ARTEON_ACCEL_PEDAL_POS_2
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Accelerator pedal torque limit ARTEON_ACCEL_PEDAL_TQ_LIM
- Service 22
DID 1059 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
All-wheel drive front-rear speed differential ARTEON_PQ35_HAL_F_R_VSS_DIFFConfirmed
- Service 22
DID 2BF0 - Module
70F → 779 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Aux. hydraulic pump RPM ARTEON_AUX_HYDRAULIC_PMP_RPM
- Service 22
DID 70D6 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Camshaft speed ARTEON_CAM_SPD
- Service 22
DID 1092 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Camshaft speed ARTEON_CAMSHAFT_VSS
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Compressor speed ARTEON_COMP_SPD
- Service 22
DID 46E1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Crankshaft speed ARTEON_CRANKSHAFT_VSS
Pelican can show this parameter as the engine speed.
- Service 22
DID 16F3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Crankshaft speed, RPM ARTEON_CRANK_SPD_RPM
- Service 22
DID 206E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Engine RPM ARTEON_RPM
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Engine RPM at idle required ARTEON_ENGINE_RPM_AT_IDLE_REQUIRED
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Front left wheel speed ARTEON_PQ35_FL_VSSConfirmed
- Service 22
DID 2B1B - Module
70F → 779 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front right wheel speed ARTEON_PQ35_FR_VSSConfirmed
- Service 22
DID 2B1C - Module
70F → 779 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Front right wheel speed ARTEON_TIRE_FR_SPD_V3
- Service 22
DID 1001 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Idle speed specified rpm ARTEON_IDLE_SPD_SPEC_RPM
- Service 22
DID 4056 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Injection speed injector 0 ARTEON_INJ_SPD_INJ_0
- Service 22
DID 10A4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Injection speed injector 1 ARTEON_INJ_SPD_INJ_1
- Service 22
DID 10A5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Injection speed injector 2 ARTEON_INJ_SPD_INJ_2
- Service 22
DID 10A6 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Injection speed injector 3 ARTEON_INJ_SPD_INJ_3
- Service 22
DID 10A8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Input shaft speed 1 ARTEON_INPUT_SHFT_SPD_1
- Service 22
DID 70E0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Input shaft speed 2 ARTEON_INPUT_SHFT_SPD_2
- Service 22
DID 70E1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Lateral acceleration ARTEON_LATERAL_ACCEL
- Service 22
DID 1644 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Longitudinal acceleration ARTEON_LONGITUDINAL_ACCEL
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Longitudinal acceleration, raw ARTEON_LONGTITUDINAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Misfires per 1000 rpm, all cylinders ARTEON_MIS_PER_1000_RPM_ALL
- Service 22
DID 148B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 rpm:, cylinder 1 ARTEON_MIS_PER_1000_RPM_1
- Service 22
DID 1484 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 rpm:, cylinder 3 ARTEON_MIS_PER_1000_RPM_3
- Service 22
DID 1486 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 rpm:, cylinder 4 ARTEON_MIS_PER_1000_RPM_4
- Service 22
DID 1485 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 rpm:, cylinder 5 ARTEON_MIS_PER_1000_RPM_5
- Service 22
DID 1489 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires per 1000 rpm:, cylinder 6 ARTEON_MIS_PER_1000_RPM_6
- Service 22
DID 1487 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires/1000 rpm, cylinder 1 ARTEON_MISFIRES_1000_RPM_C1
- Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires/1000 rpm, cylinder 2 ARTEON_MISFIRES_1000_RPM_C2
- Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires/1000 rpm, cylinder 3 ARTEON_MISFIRES_1000_RPM_C3
- Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires/1000 rpm, cylinder 4 ARTEON_MISFIRES_1000_RPM_C4
- Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Mixture adaptation factor at idle speed ARTEON_MIXTURE_ADPT_FACTOR_IDLE
- Service 22
DID 3997 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Rear left wheel speed ARTEON_PQ35_RL_VSSConfirmed
- Service 22
DID 2B1D - Module
70F → 779 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Rear right wheel speed ARTEON_PQ35_RR_VSSConfirmed
- Service 22
DID 2B1E - Module
70F → 779 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Reducing agent pump, differential speed calculated ARTEON_REDUCING_AGENT_PMP
- Service 22
DID 18CC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Specified idle RPM ARTEON_MQB_DQ250_SPECIFIED_IDLE_RPMConfirmed
- Service 22
DID 3871 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Vehicle lateral acceleration, raw value ARTEON_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 g
- Unit
- g
In testing for 2017 to 2026.
Vehicle speed ARTEON_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Vehicle speed ARTEON_VSS_7E1
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2020 to 2021.
Vehicle speed ESP ARTEON_VSS_ESP
- Service 22
DID 1005 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Vehicle speed, HR ARTEON_VSS_HR
- Service 22
DID 2106 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Yaw acceleration, raw value ARTEON_YAW_ACCEL_RAW
- Service 22
DID 15D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2017 to 2026.
Tires
Entire energy throughput ARTEON_ENTIRE_ENERGY
- Service 22
DID 2A18 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -838860 to 838860 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Hydraulic brake booster ARTEON_HYDR_BRAKEBOOSTConfirmed
- Service 22
DID 1810 - Module
713 → 77D - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Steering wheel angle ARTEON_STEER_WHEEL_ANGLEConfirmed
- Service 22
DID 1812 - Module
712 → 77C - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 °
- Unit
- °
0x0001 = 1 → = 0.125 °
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Steering wheel temperature ARTEON_STEER_WHL_T
- Service 22
DID 5505 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2017 to 2026.
Steering wheel torque sensor 1 ARTEON_STEER_WHL_TQ_SENS_1
- Service 22
DID 1805 - Module
712 → 77C - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -143.9553 to 144.0709 °
- Unit
- °
In testing for 2017 to 2026.
Steering wheel torque sensor 2 ARTEON_STEER_WHL_TQ_SENS_2
- Service 22
DID 1806 - Module
712 → 77C - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -143.9553 to 144.0709 °
- Unit
- °
In testing for 2017 to 2026.
Transmission
Adaptation counter PF lockup clutch ARTEON_ADPT_CNT_PF_LOCKUP
- Service 22
DID 1103 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, clutch a ARTEON_ADPT_CNT_CLU
- Service 22
DID 7085 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, clutch b ARTEON_ADPT_CNT_CLU_B
- Service 22
DID 7089 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, clutch c ARTEON_ADPT_CNT_CLU_C
- Service 22
DID 708D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, clutch d ARTEON_ADPT_CNT_CLU_D
- Service 22
DID 7091 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, clutch e ARTEON_ADPT_CNT_CLU_E
- Service 22
DID 7095 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, fast fill time, clutch a ARTEON_ADPT_CNT_FAST_FILL
- Service 22
DID 7087 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, fast fill time, clutch b ARTEON_ADPT_CNT_FAST_FILL_B
- Service 22
DID 708B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, fast fill time, clutch c ARTEON_ADPT_CNT_FAST_FILL_C
- Service 22
DID 708F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, fast fill time, clutch d ARTEON_ADPT_CNT_FAST_FILL_D
- Service 22
DID 7093 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, fast fill time, clutch e ARTEON_ADPT_CNT_FAST_FILL_E
- Service 22
DID 7097 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Adaptation counter, torque converter lockup clutch ARTEON_ADPT_CNT_TSF_LOCKUP
- Service 22
DID 1101 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Adaptation fill time, torque converter lockup clutch ARTEON_ADPT_INFLATION_TIME
- Service 22
DID 1100 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 2017 to 2026.
Adaptation inflation current PF lockup clutch ARTEON_ADPT_INFLATION
- Service 22
DID 1102 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mA
- Unit
- mA
In testing for 2017 to 2026.
Automatic transmission input speed ARTEON_AT_INPUT_SPEEDConfirmed
- Service 22
DID 2102 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Automatic transmission output speed ARTEON_AT_OUTPUT_SPEEDConfirmed
- Service 22
DID 2103 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Clutch 1 lower adaptation point ARTEON_CLU_1_LO_ADPT_POINT
- Service 22
DID 1120 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Clutch 1 nominal pressure ARTEON_CLU_1_NOMINAL_P
- Service 22
DID 125C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2017 to 2026.
Clutch 1 upper adaptation point ARTEON_CLU_1_HI_ADPT_POINT
- Service 22
DID 1124 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Clutch 2 adaptation basic characteristic point 2 moment ARTEON_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT
- Service 22
DID 1071 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 adaptation basic characteristic point 3 moment ARTEON_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT
- Service 22
DID 1073 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 adaptation basic characteristic point 3 position ARTEON_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS
- Service 22
DID 1072 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 adaptation end position closed ARTEON_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED
- Service 22
DID 1075 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 adaptation end position opened ARTEON_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED
- Service 22
DID 1074 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 characteristic curve shift ARTEON_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT
- Service 22
DID 1078 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.11 to 32.111 mm
- Unit
- mm
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 friction value correction factor ARTEON_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR
- Service 22
DID 1077 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Clutch 2 lower adaptation point ARTEON_CLU_2_LO_ADPT_POINT
- Service 22
DID 1121 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Clutch 2 upper adaptation point ARTEON_CLU_2_HI_ADPT_POINT
- Service 22
DID 1125 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Clutch overheating, clutch ARTEON_CLU_OVERHEATING_CLU
- Service 22
DID 17FD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Clutch temperature ARTEON_CLU_T
- Service 22
DID 1259 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Current gear ARTEON_CURRENT_GEAR
- Service 22
DID 3EDE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2017 to 2026.
Current gear ARTEON_GEARConfirmed
The automatic transmission gear.
- Service 22
DID 210F - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x01 = 1 → 1
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Current gear ARTEON_MQB_TCM_I_GEAR_DQ200Confirmed
- Service 22
DID 3816 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253
- Unit
- Number
0x02 = 2 → = 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Current N371 pressure control valve 6 lock-up clutch ARTEON_CURRENT_N371_P_CTRL_6
- Service 22
DID 1029 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2017 to 2026.
Dynamic shift program ARTEON_DYNAMIC_SHIFT
- Service 22
DID 2115 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for oxygen shift, cylinder 1 ARTEON_EARLY_IGN_CNT_OXYGEN_1
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for oxygen shift, cylinder 2 ARTEON_EARLY_IGN_CNT_OXYGEN_2
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for oxygen shift, cylinder 3 ARTEON_EARLY_IGN_CNT_OXYGEN_3
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Early ignition counter for oxygen shift, cylinder 4 ARTEON_EARLY_IGN_CNT_OXYGEN_4
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Fast fill time, clutch a ARTEON_FAST_FILL_TIME_CLU
- Service 22
DID 7086 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2017 to 2026.
Fast fill time, clutch b ARTEON_FAST_FILL_TIME_CLU_B
- Service 22
DID 708A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2017 to 2026.
Fast fill time, clutch c ARTEON_FAST_FILL_TIME_CLU_C
- Service 22
DID 708E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2017 to 2026.
Fast fill time, clutch d ARTEON_FAST_FILL_TIME_CLU_D
- Service 22
DID 7092 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2017 to 2026.
Fast fill time, clutch e ARTEON_FAST_FILL_TIME_CLU_E
- Service 22
DID 7096 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2017 to 2026.
Fill pressure, clutch a ARTEON_FILL_P_CLU
- Service 22
DID 7084 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2017 to 2026.
Fill pressure, clutch b ARTEON_FILL_P_CLU_B
- Service 22
DID 7088 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2017 to 2026.
Fill pressure, clutch c ARTEON_FILL_P_CLU_C
- Service 22
DID 708C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2017 to 2026.
Fill pressure, clutch d ARTEON_FILL_P_CLU_D
- Service 22
DID 7090 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2017 to 2026.
Fill pressure, clutch e ARTEON_FILL_P_CLU_E
- Service 22
DID 7094 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2017 to 2026.
Gear ARTEON_GEAR_V2Confirmed
- Service 22
DID 14CB - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Gear actuator adaptation engaged position GR ARTEON_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GRConfirmed
- Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
0x3801 = 14337 → = 143.37 mm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Gear actuator adaptation synchronization position reverse ARTEON_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GRConfirmed
- Service 22
DID 10AF - Module
7E1 → 7E9 - Every
3600 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
0x6B00 = 27392 → = 273.92 mm
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Launch control counter, clutch 1 ARTEON_LAUNCH_CTRL_CNT_CLU_1
- Service 22
DID 38C0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Load shift flaps, actual value ARTEON_LOAD_SHIFT_FLAPS_ACT
- Service 22
DID 295C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Load shift flaps, specified value ARTEON_LOAD_SHIFT_FLAPS_SPEC
- Service 22
DID 295D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Mileage of oxidation catalytic converter ARTEON_MILEAGE_OXIDATION
- Service 22
DID 51A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2017 to 2026.
Mileage of SCR catalytic converter ARTEON_MILEAGE_SCR
- Service 22
DID 519E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2017 to 2026.
Nominal pressure clutch 2 ARTEON_NOMINAL_P_CLU_2
- Service 22
DID 125D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2017 to 2026.
Powertrain overall gear ratio ARTEON_POWERTRAIN_OVERALL
- Service 22
DID 11DF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Number
In testing for 2017 to 2026.
Pressure_clutch_1 ARTEON_P_CLU_1
- Service 22
DID 1260 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Pressure_clutch_2 ARTEON_P_CLU_2
- Service 22
DID 1261 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2017 to 2026.
Selected gear ARTEON_SELECTED_GEAR
- Service 22
DID 7050 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253 °C
- Unit
- °C
In testing for 2017 to 2026.
Shift process, selected gear ARTEON_SHIFT_PROCCESS
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Shift process, target gear ARTEON_SHIFT_PROCCESS_TGT
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Specified torque clutch 1 - data ARTEON_SPEC_TQ_CLU_1_DATA
- Service 22
DID 2142 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Specified torque clutch 2 - data ARTEON_SPEC_TQ_CLU_2_DATA
- Service 22
DID 2143 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Time since shift ARTEON_TIME_SINCE_SHIFT
- Service 22
DID 1033 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2017 to 2026.
Torque converter amplification ARTEON_TQ_CONV
- Service 22
DID 2130 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
In testing for 2017 to 2026.
Torque converter lockup clutch status ARTEON_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUSConfirmed
- Service 22
DID 7078 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Torque loss adaptation, A/C compressor + gear engaged ARTEON_TQ_LOSS_ADPT_AC_COMP
- Service 22
DID 1222 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Torque loss adaptation, gear engaged ARTEON_TQ_LOSS_ADPT_GEAR
- Service 22
DID 1224 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2017 to 2026.
Transmission coolant valve, open ARTEON_TRANS_CLT_VLV_OPEN
- Service 22
DID 3D74 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Transmission fluid temperature 2 ARTEON_ATF_T_2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 38BF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission gear ratio ARTEON_TRANS_GEAR_RAT
- Service 22
DID 0327 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1.28 to 1.27
- Unit
- Number
In testing for 2017 to 2026.
Trips
Analysis, clutch 1 temperature time in range 1 ARTEON_ANALYSIS_CLU_1_T_1
- Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 1 temperature time in range 2 ARTEON_ANALYSIS_CLU_1_T_2
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 1 temperature time in range 3 ARTEON_ANALYSIS_CLU_1_T_3
- Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 2 temperature time in range 0 ARTEON_ANALYSIS_CLU_2_T_0
- Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 2 temperature time in range 1 ARTEON_ANALYSIS_CLU_2_T_1
- Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 2 temperature time in range 2 ARTEON_ANALYSIS_CLU_2_T_2
- Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Analysis, clutch 2 temperature time in range 3 ARTEON_ANALYSIS_CLU_2_T_3
- Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Clutch 1 temperature time in range 0 ARTEON_CLU_1_T_TIME_RANGE_0
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2017 to 2026.
Distance to empty ARTEON_DTE
Pelican can show this parameter as the fuel range.
- Service 22
DID 2294 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Drive cycles counter ARTEON_MQB_TCM_DRIVE_CYCLES_COUNTERConfirmed
- Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0xF70D = 63245 → 63,245
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Driving time ecological ARTEON_MQB_TCM_DRIVING_TIME_ECOLOGICALConfirmed
- Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Driving time manual ARTEON_MQB_TCM_DRIVING_TIME_MANUALConfirmed
- Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Driving time sporty ARTEON_MQB_TCM_DRIVING_TIME_SPORTYConfirmed
- Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Ignition cycles ARTEON_MQB_TCM_IGNITION_CYCLESConfirmed
- Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x6518 = 25880 → 25,880
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Mixture variation in adapted part load range 1 ARTEON_MIXTURE_VARIATION_1
- Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Odometer ARTEON_ODO_7E0
Pelican can show this parameter as the odometer.
- Service 22
DID 108C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2017 to 2026.
Odometer ARTEON_ODO_7E1_2
Pelican can show this parameter as the odometer.
- Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Odometer ARTEON_ODO_ECMConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
7E0 → 7E8 - Every
30 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00E3D4 = 58324 → 58,324 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Odometer ARTEON_ODO_V1Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3841 - Module
7E1 → 7E9 - Every
1 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x0008E648 = 583240 → = 58,324 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Odometer ARTEON_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- -40 to 16777175 km
- Unit
- km
In testing for 2017 to 2019, 2022 to 2026. Supported for 2020. Not supported for 2021.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2020 to 2021.
Odometer #2 ARTEON_MQB_TCM_ODO_2Confirmed
- Service 22
DID 3887 - Module
7E1 → 7E9 - Every
30 s - Testing for 2017 to 2019, 2022 to 2026
Example reply from a 2021 Volkswagen Arteon.
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x00000000 = 0 → = 0 km
Confirmed for 2020 to 2021. In testing for 2017 to 2019, 2022 to 2026.
Odometer at oxidation catalytic converter replacement ARTEON_ODO_OXYDATION
- Service 22
DID 4F3F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2017 to 2026.
Odometer at SCR catalytic converter replacement ARTEON_ODO_SCR_CATALYTIC
- Service 22
DID 4F41 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2017 to 2026.
Odometer with ECU installed ARTEON_ODO_ECU_INSTALLED
- Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 m
- Unit
- m
In testing for 2017 to 2026.
Odometer, dashboard ARTEON_ODO_DASHConfirmed
- Service 22
DID 2203 - Module
714 → 77E - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 Volkswagen Arteon.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0149E4 = 84452 → 84,452 km
Confirmed for 2020. In testing for 2017 to 2019, 2022 to 2026. Not supported for 2021.
Odometer, high resolution ARTEON_ODO_HD
Pelican can show this parameter as the odometer.
- Service 22
DID 1160 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 km
- Unit
- km
In testing for 2017 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Odometer, mileage, HR ARTEON_ODO_MILEAGE_HR
- Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2017 to 2026.
Operating time, temperature range 1 ARTEON_OP_TIME_T_RANGE_1
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Operating time, temperature range 2 ARTEON_OP_TIME_T_RANGE_2
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Operating time, temperature range 3 ARTEON_OP_TIME_T_RANGE_3
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Operating time, temperature range 4 ARTEON_OP_TIME_T_RANGE_4
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Operating time, temperature range 5 ARTEON_OP_TIME_T_RANGE_5
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Operating time, temperature range 6 ARTEON_OP_TIME_T_RANGE_6
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2017 to 2026.
Remaining distance until reducing agent deficiency ARTEON_REMAINING_DIST_UNTIL
- Service 22
DID 29B1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 214748364 km
- Unit
- km
In testing for 2017 to 2026.
Torque converter time in temperature range 1 ARTEON_TQ_CONV_TIME_T_RANGE_1
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 2 ARTEON_TQ_CONV_TIME_T_RANGE_2
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 3 ARTEON_TQ_CONV_TIME_T_RANGE_3
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 4 ARTEON_TQ_CONV_TIME_T_RANGE_4
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 5 ARTEON_TQ_CONV_TIME_T_RANGE_5
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 6 ARTEON_TQ_CONV_TIME_T_RANGE_6
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 143 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 7 ARTEON_TQ_CONV_TIME_T_RANGE_7
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 144 to 167 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.
Torque converter time in temperature range 8 ARTEON_TQ_CONV_TIME_T_RANGE_8
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 168 to 191 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2017 to 2026.