Volkswagen ID.3

Parameters

The Volkswagen ID.3 has 318 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage ID3_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x20D7 = 8407 → 84071000+4 = 12.407 V

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity ID3_AUX_BAT_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

0x31 = 49 → 49 Ah

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery aging by capacity ID3_AUX_BAT_AGE_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery aging by power ID3_AUX_BAT_AGE_POWConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x54 = 84 → 84 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery current ID3_AUX_BAT_CConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

0xFFFFD6E4 = -10524 → -105241000 = -10.524 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery soc ID3_AUX_BAT_SOCConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x62 = 98 → 98 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery total charge ID3_AUX_BAT_CHRG_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x000049A9 = 18857 → 1885710 = 1,885.7 Ah

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery total discharge ID3_AUX_BAT_DSCH_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x000042CE = 17102 → 1710210 = 1,710.2 Ah

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

12V battery voltage ID3_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x20D7 = 8407 → 84071000+4 = 12.407 V

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

AC charging ID3_AC_CHARGINGConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Average battery consumption ID3_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x15 = 21 → 21 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Battery cell soc max, ID ID3_HVBAT_CELL_SOC_MAX_IDConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery cell soc min, ID ID3_HVBAT_CELL_SOC_MIN_IDConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery cell soc, maximum ID3_HVBAT_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery cell soc, minimum ID3_HVBAT_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery control module temperature ID3_HVBAT_ECU_TConfirmed

  • Service 22DID 1622
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery current limit, charging ID3_HVBAT_I_LIM_CHGConfirmed

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery current limit, discharging ID3_HVBAT_I_LIM_DSCHConfirmed

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery current, DC, second reading ID3_HVBAT_I_DC_2Confirmed

  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val100−1500
Range
-1500 to 42948172.95 A
Unit
A

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery current, motor controller ID3_HVBAT_I_ENGConfirmed

  • Service 22DID 035E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Battery heater current ID3_HVBAT_PTC_IConfirmed

  • Service 22DID 1620
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery heater temperature, #1 ID3_HVBAT_PTC_T_1Confirmed

  • Service 22DID 1623
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery heater temperature, #2 ID3_HVBAT_PTC_T_2Confirmed

  • Service 22DID 1624
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery heater voltage ID3_HVBAT_PTC_VConfirmed

  • Service 22DID 1621
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery internal resistance, raw ID3_BAT_INTERNAL_RES_RAWConfirmed

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

0x00 = 0 → 05 = 0

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Battery temperature, inlet ID3_HVBAT_T_INConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery temperature, max ID3_HVBAT_T_MAXConfirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery temperature, max sensor ID ID3_HVBAT_T_MAX_IDConfirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery temperature, min ID3_HVBAT_T_MINConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery temperature, min sensor ID ID3_HVBAT_T_MIN_IDConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery temperature, outlet ID3_HVBAT_T_OUTConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery voltage, after main switch ID3_HVBAT_V_AFTERConfirmed

  • Service 22DID 1E38
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery voltage, before main switch ID3_HVBAT_V_BEFOREConfirmed

  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery voltage, charging ID3_HVBAT_V_CHGConfirmed

  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×31249978510000000000
Range
-1023.999 to 1023.967 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Battery voltage, traction mode ID3_HVBAT_V_TRACConfirmed

  • Service 22DID 4675
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 V
Unit
V

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Charge voltage, max ID3_MAXIMUM_CHARGE_VConfirmed

  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

Charger coolant temperature ID3_CHRGR_COOLANT_TConfirmed

  • Service 22DID 15E2
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x36 = 54 → 54−40 = 14 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Charging duration total ID3_CHRGR_DUR_TOTALConfirmed

  • Service 22DID 15EE
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

0x00007825 = 30757 → 30,757 min

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Charging, rapid? ID3_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Coolant temperature at the DC/DC converter ID3_DCDC_T_COOLConfirmed

  • Service 22DID 43B8
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Current gear ID3_DRIVE_MODEConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Cycle energy transformation ID3_OBC_CYCLE_ENERGYConfirmed

  • Service 22DID 103E
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kWh
Unit
kWh

0x0000 = 0 → 0100 = 0 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

DC battery voltage ID3_DC_BATTERY_VConfirmed

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

DC-DC converter current, alternate ID3_DCDC_I_ALTConfirmed

  • Service 22DID 465B
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 A
Unit
A

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

DC-DC converter, current ID3_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

DC-DC converter, low voltage ID3_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x7C = 124 → 12410 = 12.4 V

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

DC-DC converter, reserved current ID3_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

DC-DC voltage ID3_DC_DC_VConfirmed

  • Service 22DID 465D
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9980469 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Discharge voltage, min ID3_MINIMUM_DISCHARGE_VConfirmed

  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

ECall battery charge level ID3_ECALL_SOCConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5D = 93 → 93 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Ecall battery charge status ID3_ECALL_BATTERY_CHARGE_STATUSConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x02 = 2 → 2

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Electric machine high-voltage battery energy information ID3_HIGH_V_EM_HVBATConfirmed

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Volkswagen ID.3.

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

0x0000 = 0 → 020 = 0 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Electric motor battery energy ID3_HV_EM_HVBAT_ENERGY_INFORMATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

0x014A = 330 → 330×501000 = 16.5 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Estimated electric power reserve ID3_RANGE_RESERVE_ESTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x009A = 154 → 154 km

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Estimated reserve range ID3_RANGE_EST_CANConfirmed

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x009A = 154 → 154 km

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

High voltage battery energy information ID3_HVBAT_ENERGYConfirmed

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

0x0000 = 0 → 040 = 0 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

High voltage output ID3_OBC_HIGH_V_OUTPUTConfirmed

  • Service 22DID 1DA7
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0D36 = 3382 → 338210 = 338.2 V

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

HV auxiliary current total ID3_HVAUX_IConfirmed

  • Service 22DID 0360
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

HV auxiliary power ID3_HVAUX_PWRConfirmed

  • Service 22DID 0364
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kW
Unit
kW

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

HV battery after contacts voltage ID3_HVBAT_AFTER_CONTACTS_VConfirmed

  • Service 22DID 189B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 V
Unit
V

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

HV battery cell voltage max, ID ID3_HVBAT_CELL_V_MAX_IDConfirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2023.

HV battery cell voltage min, ID ID3_HVBAT_CELL_V_MIN_IDConfirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery energy ID3_HVBAT_KWHConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638 kWh
Unit
kWh

0x0293 = 659 → 659×251000 = 16.475 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

HV battery module temperature, #1 ID3_HVBAT_MOD_T_1Confirmed

  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery module temperature, #2 ID3_HVBAT_MOD_T_2Confirmed

  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery module temperature, #3 ID3_HVBAT_MOD_T_3Confirmed

  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery module temperature, #4 ID3_HVBAT_MOD_T_4Confirmed

  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery module temperature, #17 ID3_HVBAT_MOD_T_17Confirmed

  • Service 22DID 7425
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery: circulation pump flow ID3_CIRC_PUMP_FLOWConfirmed

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Non-vehicle energy requirement ID3_NV_ENERGY_REQUIREMENTConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

0x33 = 51 → 51×501000 = 2.55 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

On-board charger, hv/dc current ID3_OBC_HVDC_CConfirmed

  • Service 22DID 103D
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Power efficiency ID3_CHRGR_EFFICIENCYConfirmed

  • Service 22DID 15D6
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
75 to 100.5 A
Unit
A

0x00 = 0 → 010+75 = 75 A

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Rail 1 energy transformation ID3_CHRGR_RAIL1_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x002FB4 = 12212 → 1221210 = 1,221.2 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Rail 2 energy transformation ID3_CHRGR_RAIL2_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 24 to 47 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x003002 = 12290 → 1229010 = 1,229 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Rail 3 energy transformation ID3_CHRGR_RAIL3_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 48 to 71 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x002FD0 = 12240 → 1224010 = 1,224 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Start/stop battery resistance ID3_SSB_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×210
Range
0 to 51 mΩ
Unit
mΩ

0x00 = 0 → 0×210 = 0 mΩ

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

State of charge ID3_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 3DEF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

State of charge, display ID3_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20.446−6.4
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2023. In testing for 2022, 2024 to 2026. Not supported for 2021.

Temperature sensor, socket a ID3_OBC_T_AConfirmed

  • Service 22DID 1DDA
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498.5 °C
Unit
°C

0x0352 = 850 → 85010−55 = 30 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, 12V battery ID3_AUX_BAT_TConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, 12V battery sensor ID3_AUX_BAT_T_SConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3B = 59 → 59−40 = 19 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, battery ID3_BATTERY_TConfirmed

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Voltage proximity, socket a ID3_OBC_V_PROX_AConfirmed

  • Service 22DID 1525
  • Module744 → 7AE
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x1230 = 4656 → 4,656 mV

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Cells

HV battery cell voltage, #1 ID3_HVBAT_CELL_V_001Confirmed

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #2 ID3_HVBAT_CELL_V_002Confirmed

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #3 ID3_HVBAT_CELL_V_003Confirmed

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #4 ID3_HVBAT_CELL_V_004Confirmed

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #5 ID3_HVBAT_CELL_V_005Confirmed

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #6 ID3_HVBAT_CELL_V_006Confirmed

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #7 ID3_HVBAT_CELL_V_007Confirmed

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #8 ID3_HVBAT_CELL_V_008Confirmed

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #9 ID3_HVBAT_CELL_V_009Confirmed

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #10 ID3_HVBAT_CELL_V_010Confirmed

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #11 ID3_HVBAT_CELL_V_011Confirmed

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #12 ID3_HVBAT_CELL_V_012Confirmed

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #13 ID3_HVBAT_CELL_V_013Confirmed

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #14 ID3_HVBAT_CELL_V_014Confirmed

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #15 ID3_HVBAT_CELL_V_015Confirmed

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #16 ID3_HVBAT_CELL_V_016Confirmed

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #17 ID3_HVBAT_CELL_V_017Confirmed

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #18 ID3_HVBAT_CELL_V_018Confirmed

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #19 ID3_HVBAT_CELL_V_019Confirmed

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #20 ID3_HVBAT_CELL_V_020Confirmed

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #21 ID3_HVBAT_CELL_V_021Confirmed

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #22 ID3_HVBAT_CELL_V_022Confirmed

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #23 ID3_HVBAT_CELL_V_023Confirmed

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #24 ID3_HVBAT_CELL_V_024Confirmed

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #25 ID3_HVBAT_CELL_V_025Confirmed

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #26 ID3_HVBAT_CELL_V_026Confirmed

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #27 ID3_HVBAT_CELL_V_027Confirmed

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #28 ID3_HVBAT_CELL_V_028Confirmed

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #29 ID3_HVBAT_CELL_V_029Confirmed

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #30 ID3_HVBAT_CELL_V_030Confirmed

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #31 ID3_HVBAT_CELL_V_031Confirmed

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #32 ID3_HVBAT_CELL_V_032Confirmed

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #33 ID3_HVBAT_CELL_V_033Confirmed

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #34 ID3_HVBAT_CELL_V_034Confirmed

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #35 ID3_HVBAT_CELL_V_035Confirmed

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #36 ID3_HVBAT_CELL_V_036Confirmed

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #37 ID3_HVBAT_CELL_V_037Confirmed

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #38 ID3_HVBAT_CELL_V_038Confirmed

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #39 ID3_HVBAT_CELL_V_039Confirmed

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #40 ID3_HVBAT_CELL_V_040Confirmed

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #41 ID3_HVBAT_CELL_V_041Confirmed

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #42 ID3_HVBAT_CELL_V_042Confirmed

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #43 ID3_HVBAT_CELL_V_043Confirmed

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #44 ID3_HVBAT_CELL_V_044Confirmed

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #45 ID3_HVBAT_CELL_V_045Confirmed

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #46 ID3_HVBAT_CELL_V_046Confirmed

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #47 ID3_HVBAT_CELL_V_047Confirmed

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #48 ID3_HVBAT_CELL_V_048Confirmed

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #49 ID3_HVBAT_CELL_V_049Confirmed

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #50 ID3_HVBAT_CELL_V_050Confirmed

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #51 ID3_HVBAT_CELL_V_051Confirmed

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #52 ID3_HVBAT_CELL_V_052Confirmed

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #53 ID3_HVBAT_CELL_V_053Confirmed

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #54 ID3_HVBAT_CELL_V_054Confirmed

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #55 ID3_HVBAT_CELL_V_055Confirmed

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #56 ID3_HVBAT_CELL_V_056Confirmed

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #57 ID3_HVBAT_CELL_V_057Confirmed

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #58 ID3_HVBAT_CELL_V_058Confirmed

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #59 ID3_HVBAT_CELL_V_059Confirmed

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #60 ID3_HVBAT_CELL_V_060Confirmed

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #61 ID3_HVBAT_CELL_V_061Confirmed

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #62 ID3_HVBAT_CELL_V_062Confirmed

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #63 ID3_HVBAT_CELL_V_063Confirmed

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #64 ID3_HVBAT_CELL_V_064Confirmed

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #65 ID3_HVBAT_CELL_V_065Confirmed

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #66 ID3_HVBAT_CELL_V_066Confirmed

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #67 ID3_HVBAT_CELL_V_067Confirmed

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #68 ID3_HVBAT_CELL_V_068Confirmed

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #69 ID3_HVBAT_CELL_V_069Confirmed

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #70 ID3_HVBAT_CELL_V_070Confirmed

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #71 ID3_HVBAT_CELL_V_071Confirmed

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #72 ID3_HVBAT_CELL_V_072Confirmed

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #73 ID3_HVBAT_CELL_V_073Confirmed

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #74 ID3_HVBAT_CELL_V_074Confirmed

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #75 ID3_HVBAT_CELL_V_075Confirmed

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #76 ID3_HVBAT_CELL_V_076Confirmed

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #77 ID3_HVBAT_CELL_V_077Confirmed

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #78 ID3_HVBAT_CELL_V_078Confirmed

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #79 ID3_HVBAT_CELL_V_079Confirmed

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #80 ID3_HVBAT_CELL_V_080Confirmed

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #81 ID3_HVBAT_CELL_V_081Confirmed

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #82 ID3_HVBAT_CELL_V_082Confirmed

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #83 ID3_HVBAT_CELL_V_083Confirmed

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #84 ID3_HVBAT_CELL_V_084Confirmed

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #85 ID3_HVBAT_CELL_V_085Confirmed

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #86 ID3_HVBAT_CELL_V_086Confirmed

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #87 ID3_HVBAT_CELL_V_087Confirmed

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #88 ID3_HVBAT_CELL_V_088Confirmed

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #89 ID3_HVBAT_CELL_V_089Confirmed

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #90 ID3_HVBAT_CELL_V_090Confirmed

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #91 ID3_HVBAT_CELL_V_091Confirmed

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #92 ID3_HVBAT_CELL_V_092Confirmed

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #93 ID3_HVBAT_CELL_V_093Confirmed

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #94 ID3_HVBAT_CELL_V_094Confirmed

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #95 ID3_HVBAT_CELL_V_095Confirmed

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #96 ID3_HVBAT_CELL_V_096Confirmed

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #97 ID3_HVBAT_CELL_V_097Confirmed

  • Service 22DID 1EA0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #98 ID3_HVBAT_CELL_V_098Confirmed

  • Service 22DID 1EA1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #99 ID3_HVBAT_CELL_V_099Confirmed

  • Service 22DID 1EA2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #100 ID3_HVBAT_CELL_V_100Confirmed

  • Service 22DID 1EA3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #101 ID3_HVBAT_CELL_V_101Confirmed

  • Service 22DID 1EA4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #102 ID3_HVBAT_CELL_V_102Confirmed

  • Service 22DID 1EA5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #103 ID3_HVBAT_CELL_V_103Confirmed

  • Service 22DID 1EA6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #104 ID3_HVBAT_CELL_V_104Confirmed

  • Service 22DID 1EA7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #105 ID3_HVBAT_CELL_V_105Confirmed

  • Service 22DID 1EA8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #106 ID3_HVBAT_CELL_V_106Confirmed

  • Service 22DID 1EA9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #107 ID3_HVBAT_CELL_V_107Confirmed

  • Service 22DID 1EAA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

HV battery cell voltage, #108 ID3_HVBAT_CELL_V_108Confirmed

  • Service 22DID 1EAB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Modules

HV battery module temperature, #5 ID3_HVBAT_MOD_T_5Confirmed

  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #6 ID3_HVBAT_MOD_T_6Confirmed

  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #7 ID3_HVBAT_MOD_T_7Confirmed

  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #8 ID3_HVBAT_MOD_T_8Confirmed

  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #9 ID3_HVBAT_MOD_T_9Confirmed

  • Service 22DID 1EB6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #10 ID3_HVBAT_MOD_T_10Confirmed

  • Service 22DID 1EB7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #11 ID3_HVBAT_MOD_T_11Confirmed

  • Service 22DID 1EB8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #12 ID3_HVBAT_MOD_T_12Confirmed

  • Service 22DID 1EB9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #13 ID3_HVBAT_MOD_T_13Confirmed

  • Service 22DID 1EBA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #14 ID3_HVBAT_MOD_T_14Confirmed

  • Service 22DID 1EBB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #15 ID3_HVBAT_MOD_T_15Confirmed

  • Service 22DID 1EBC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

HV battery module temperature, #16 ID3_HVBAT_MOD_T_16Confirmed

  • Service 22DID 1EBD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

Climate

Air pollution level ID3_AIR_POLUTIONConfirmed

0 means clean air.

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.7 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

CO2 content interior ID3_CO2_CONTENT_INTERIORConfirmed

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

0xFE = 254 → 254×100 = 25,400

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Humidity, inside ID3_HVAC_INSIDE_HUMConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x97 = 151 → 1512 = 75.5 %

Confirmed for 2023. In testing for 2022, 2024 to 2026. Not supported for 2020 to 2021.

Outside humidity ID3_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2022, 2024 to 2026. Not supported for 2020 to 2021, 2023.

Outside temperature ID3_AAT_V2Confirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x7F = 127 → 1272−50 = 13.5 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Radiator fan actual #1 ID3_HVAC_FAN1_ACT

  • Service 22DID 2606
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2022, 2024 to 2026. Supported for 2020 to 2021, 2023.

Radiator fan actual #2 ID3_HVAC_FAN2_ACT

  • Service 22DID 2606
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2022, 2024 to 2026. Supported for 2020 to 2021, 2023.

Recirculation flap stop, fresh air ID3_RECIRC_FLAP_STOP_FRESHConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0028 = 40 → 40

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Recirculation flap stop, recirculated air ID3_RECIRC_FLAP_STOP_RECIRCConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00D6 = 214 → 214

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Recirculation flap, actual ID3_RECIRC_FLAP_ACT_PCTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x83 = 131 → 1312 = 65.5 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Recirculation flap, actual steps ID3_RECIRC_FLAP_ACT_STEPSConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x009A = 154 → 154

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Recirculation flap, commanded steps ID3_RECIRC_FLAP_CMD_STEPSConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x009A = 154 → 154

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Refrigerant pressure ID3_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x12 = 18 → 185 = 3.6 bar

Confirmed for 2023. In testing for 2022, 2024 to 2026. Not supported for 2020 to 2021.

Windshield, temperature ID3_WNDSHLD_TEMPConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

0x5D = 93 → 93×0.576−38.8 = 14.768 °C

Confirmed for 2023. In testing for 2022, 2024 to 2026. Not supported for 2020 to 2021.

Control

Absolute pedal position, drive ID3_APP_DConfirmed

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.55 = 0 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Brake booster pressure ID3_BRAKE_BOOSTER_PConfirmed

  • Service 22DID 2005
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Steering wheel angle ID3_STEER_ANGLEConfirmed

  • Service 22DID 0346
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °
Unit
°

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Drivetrain

Actual mechanical torque calculated ID3_ACTUAL_MECHANICAL_TORQUE_CALC

  • Service 22DID 3EE9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Actual mechanical torque commanded ID3_ACTUAL_MECHANICAL_TORQUE_CMD_VALUE

  • Service 22DID 58E1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Actual possible maximum torque ID3_ACTUAL_POSSIBLE_MAXIMUM_TORQUE

  • Service 22DID 3EEA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Actual possible minimum torque ID3_ACTUAL_POSSIBLE_MINIMUM_TORQUE

  • Service 22DID 3EEB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Electric drive ECU temperature 1 ID3_ELDRIVE_ECU_T_1

  • Service 22DID 0805
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Electric drive ECU temperature 2 ID3_ELDRIVE_ECU_T_2

  • Service 22DID 0806
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Inverter power loss phase u ID3_INVERTER_PWR_LOSS_PHASE_U

  • Service 22DID 1040
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Inverter power loss phase v ID3_INVERTER_PWR_LOSS_PHASE_V

  • Service 22DID 1041
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Inverter power loss phase w ID3_INVERTER_PWR_LOSS_PHASE_W

  • Service 22DID 1042
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 W
Unit
W

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor electrical frequency, radians per second ID3_ELDRIVE_MOTOR_FREQ

  • Service 22DID 4657
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000
Unit
Number

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor maximum current ID3_MOTOR_MAXIMUM_I

  • Service 22DID 3EE7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 A
Unit
A

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor minimum current ID3_MOTOR_MINIMUM_I

  • Service 22DID 3EE8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 A
Unit
A

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor speed ID3_MOTOR_RPM

  • Service 22DID 3DF8
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque difference, front to rear ID3_MOTOR_TRQ_DIFF

  • Service 22DID 0343
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque rated, front ID3_MOTOR_TRQ_RATED_FRONT

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque rated, rear ID3_MOTOR_TRQ_RATED_REAR

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque requested ID3_MOTOR_TRQ_REQ

  • Service 22DID 29D4
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque, front ID3_MOTOR_TRQ_FRONT

  • Service 22DID 0335
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor torque, rear ID3_MOTOR_TRQ_REAR

  • Service 22DID 033B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor voltage, d-axis actual ID3_MOTOR_V_D_ACT

  • Service 22DID 1007
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor voltage, d-axis commanded ID3_MOTOR_V_D_CMD

  • Service 22DID 1009
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor voltage, q-axis actual ID3_MOTOR_V_Q_ACT

  • Service 22DID 1008
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor voltage, q-axis commanded ID3_MOTOR_V_Q_CMD

  • Service 22DID 100A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 V
Unit
V

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Torque, calculated from measured currents ID3_CALC_FROM_MEAS_IS

  • Service 22DID 0308
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

DTCs

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2021. Supported for 2020, 2022 to 2024.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021. Supported for 2020, 2022 to 2024.

Engine

A/C clutch ID3_CLIMATE_A_C_CLCHConfirmed

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

A/C compressor load ID3_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x00 = 0 → 010 = 0 N·m

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2020 to 2022, 2024.

Coolant circulation pump duty ID3_COOLANT_CIRC_PUMP_DUTYConfirmed

  • Service 22DID 276D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Electric motor non-vehicle power limitation ID3_HV_EM_NV_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

0x00 = 0 → 0×50 = 0 W

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Electric motor power limitation ID3_HV_EM_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0000 = 0 → 0×50 = 0 W

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Energy balance of last driving cycle ID3_ENERGY_BALANCE_LASTConfirmed

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

0x0000 = 0 → 0100 = 0 Ah

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2020 to 2022, 2024.

Front left temperature flap actual ID3_FRONT_LEFT_T_FLAP_ACTConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x62 = 98 → 982 = 49 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Front right temperature flap actual ID3_FRONT_RIGHT_T_FLAP_ACTConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x69 = 105 → 1052 = 52.5 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Leg deflector temperature ID3_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x78 = 120 → 1203 = 40 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

NV energy requirement ID3_NV_ENERGYConfirmed

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Volkswagen ID.3.

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

0x00 = 0 → 020 = 0 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Outside temperature, from cabin sensor ID3_AAT_CABINConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x66 = 102 → 1022−50 = 1 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Radiator fan commanded duty ID3_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Radiator fan duty ID3_RADIATOR_FAN_DUTYConfirmed

  • Service 22DID 2055
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Rotor temperature model ID3_ROTOR_T_MODEL

  • Service 22DID 2CCC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Temperature, electric drive inflow coolant ID3_ELEC_DRIVE_INFLOW_COOLANT_T

  • Service 22DID 4FAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Temperature, evaporator output ID3_HVAC_EVAP_TConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x01CC = 460 → 46010 = 46 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, front left deflector ID3_FRONT_LEFT_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x5C = 92 → 92×0.333 = 30.636 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, front right deflector ID3_FRONT_RIGHT_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x74 = 116 → 116×0.333 = 38.628 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, interior ID3_HVAC_IATConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x011D = 285 → 28510 = 28.5 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Temperature, motor ID3_MOTOR_T

  • Service 22DID 4672
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Temperature, rear deflector ID3_REAR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x50 = 80 → 80×0.333 = 26.64 °C

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Washer nozzle heater active ID3_HTR_NOZZLEConfirmed

  • Service 22DID 1945
  • Module70E → 778
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

GPS

Satellites, tracked ID3_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Satellites, visible ID3_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Movement

A/C compressor, speed ID3_A_C_CMPR_SPEEDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Acceleration ID3_ACCELConfirmed

  • Service 22DID 4539
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Electric drive motor speed, radians per second ID3_ELDRIVE_MOTOR_RAD_SEC

  • Service 22DID 40C8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000
Unit
Number

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Motor RPM ID3_ELDRIVE_MOTOR_RPMConfirmed

  • Service 22DID F40C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Vehicle speed ID3_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2021 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021, 2023. Supported for 2020, 2022, 2024.

Tires

Steering wheel angle ID3_STEER_WHEEL_ANGLEConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−750
Range
-750 to 780 °
Unit
°

0x1138 = 4408 → 44088−750 = -199 °

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Steering wheel torque sensor 1 ID3_STEER_WHL_TQ_SENS_1Confirmed

  • Service 22DID 1805
  • Module712 → 77C
  • Every250 ms
  • Testing for 2020, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Trips

Average consumption, category 0 ID3_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B8 = 184 → 18410 = 18.4 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 1 ID3_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0060 = 96 → 9610 = 9.6 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 2 ID3_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x005C = 92 → 9210 = 9.2 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 3 ID3_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00AB = 171 → 17110 = 17.1 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 4 ID3_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0078 = 120 → 12010 = 12 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 5 ID3_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00B5 = 181 → 18110 = 18.1 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Average consumption, category 6 ID3_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Odometer ID3_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2023. In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020.

Odometer, battery management system ID3_BMS_ODO

  • Service 22DID 02BD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Odometer, battery management system, second reading ID3_ODO_BMS2

Pelican can show this parameter as the odometer.

  • Service 22DID 5867
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Odometer, electric drive ID3_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 086D
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2022, 2024 to 2026. Not supported for 2020, 2023.

Range remaining, displayed ID3_RANGEConfirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Volkswagen ID.3.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x001A = 26 → 26 mi

Confirmed for 2020 to 2021, 2023. In testing for 2022, 2024 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.