Parameters
The Volkswagen Virtus has 1,174 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery capacity VIRTUS_12V_BAT_CAP
- Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2018 to 2026.
12V battery temperature VIRTUS_BAT_SENSOR_T
- Service 22
DID 2A0A - Module
710 → 77A - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Accelerator pedal, sensor 1 voltage VIRTUS_ACCEL_PEDAL_SENS_1_V
- Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Accelerator pedal, sensor 2 voltage VIRTUS_ACCEL_PEDAL_SENS_2_V
- Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Aux. hydraulic pump voltage VIRTUS_AUX_HYDRAULIC_PMP_V
- Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2018 to 2026.
Battery acid stratification VIRTUS_BAT_ACID
- Service 22
DID 2A1D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2559 %
- Unit
- %
In testing for 2018 to 2026.
Battery charge level VIRTUS_BAT_SOCConfirmed
- Service 22
DID 2A0C - Module
710 → 77A - Every
10 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x45 = 69 → 69 %
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Battery condition for display VIRTUS_BAT_COND_DISPLAY
- Service 22
DID 2A0D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 %
- Unit
- %
In testing for 2018 to 2026.
Battery current VIRTUS_BAT_IConfirmed
- Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -1000 to 1000 A
- Unit
- A
0x00000A70 = 2672 → = 2.672 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Battery current filtered VIRTUS_BAT_CURRENT_FILTERED
- Service 22
DID 2A08 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- -3000 to 13777 A
- Unit
- A
In testing for 2018 to 2026.
Battery internal resistance VIRTUS_BAT_INT_RConfirmed
- Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
0x22 = 34 → = 6.8
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Battery internal resistance, raw VIRTUS_BAT_INTERNAL_RES_RAW
- Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
In testing for 2018 to 2026.
Battery temperature VIRTUS_BAT_TConfirmed
- Service 22
DID 2A0B - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x49 = 73 → = 33 °C
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Battery voltage VIRTUS_BAT_V
- Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2018 to 2026.
Battery voltage VIRTUS_BAT_V_2A07Confirmed
- Service 22
DID 2A07 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 4 to 69.535 V
- Unit
- V
0x20C5 = 8389 → = 12.389 V
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Battery voltage at rest VIRTUS_BAT_V_AT_RESTConfirmed
- Service 22
DID 2A10 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 9 to 34.5 V
- Unit
- V
0x22 = 34 → = 12.4 V
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Battery voltage variant VIRTUS_PQ35_BAT_V_2
- Service 22
DID 105E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2018 to 2026.
Boost pressure VIRTUS_PQ35_CHG_P
- Service 22
DID 1057 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, raw voltage VIRTUS_BYPASS_VLV_HIGH_P_V
- Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Calculated nitrogen oxide concentration behind turbocharger VIRTUS_MQB_NOX_CONC_BEHIND_TURBO
- Service 22
DID 1526 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2018 to 2026.
Charge adjuster output stage VIRTUS_HIGH_P_TURBOCHARGER
- Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value VIRTUS_CHG_AIR_COOLER_INLET_P_1_1
- Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2018 to 2026.
Charge air pressure actuator position digit.value VIRTUS_CHG_AIR_P_ACTUATOR_7E0
- Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Charge air pressure, actual value VIRTUS_AIR_P_CAC_DS
- Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Charge air pressure, actual value VIRTUS_CHG_AIR_P_ACT
- Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2018 to 2026.
Charge air pressure, specified value VIRTUS_CHG_AIR_P_SPEC
- Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Charge air pressure: actual VIRTUS_PQ35_CHARGE_AIR_P_ACTUAL
- Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2018 to 2026.
Charge air pressure: specified VIRTUS_PQ35_CHARGE_AIR_P_SPECIFIED
- Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2018 to 2026.
Charge air temp at the turbocharger outlet, calculated VIRTUS_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED
- Service 22
DID 1798 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Charge limit overcharge protection VIRTUS_PQ35_CHG_LIM_OVER
- Service 22
DID 1356 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Charge pressure actuator, acknowledgment VIRTUS_CHG_P_ACTUATOR
- Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure actuator, actual position VIRTUS_CHG_P_ACTUATOR_ACT
- Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure actuator, adaptation for lower stop VIRTUS_CHG_P_ACTUATOR_ADPT
- Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, adaptation for upper stop VIRTUS_CHG_P_ACTUATOR_ADPT_HI
- Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, maximum sensor voltage VIRTUS_CHG_P_ACTUATOR_MAX_V
- Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, specified position VIRTUS_CHG_P_ACTUATOR_SPEC
- Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure actuator, specified value VIRTUS_CHG_P_ACTUATOR_SPEC_7E0
- Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure before throttle valve, calculated actual value VIRTUS_CHG_P_BEFORE_ACT
- Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 2018 to 2026.
Charge pressure control specified value VIRTUS_CHG_P_CTRL_SPEC
- Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve activation pulse duty factor VIRTUS_CHG_P_CTRL_VLV
- Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve position, actual value VIRTUS_CHG_P_CTRL_VLV_POS_ACT
- Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve position, target value VIRTUS_CHG_P_CTRL_VLV_POS_TGT
- Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve sensor voltage VIRTUS_CHG_P_CTRL_VLV_SENS_V
- Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure control valve voltage, position closed VIRTUS_CHG_P_CTRL_VLV_V_POS
- Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure control valve voltage, position opened VIRTUS_CHG_P_CTRL_VLV_V_POS_OPENED
- Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure control, adapt. higher than max. threshold VIRTUS_CHG_P_CTRL_ADAPT_MAX
- Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control, adapt. lower than min. threshold VIRTUS_CHG_P_CTRL_ADAPT_LO_MIN
- Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure regulator, lower threshold adaptation VIRTUS_CHG_P_REGULATOR_LO
- Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure regulator, upper threshold adaptation VIRTUS_CHG_P_REGULATOR_HI
- Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure sensor, unconditioned voltage VIRTUS_CHG_P_SENS_V
- Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Control module voltage VIRTUS_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x2F6C = 12140 → = 12.14 V
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Cylinder charge specified value VIRTUS_CYL_CHG_SPEC
- Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Cylinder charge, actual value VIRTUS_CYL_CHG_ACT
- Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Electric machine high-voltage battery energy information VIRTUS_HIGH_V_EM_HVBAT
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2018 to 2026.
Exhaust gas recirculation valve 1, B1, mass current: specified value VIRTUS_MQB_EGR_VALVE_1_B1_MASS_I_SPEC
- Service 22
DID 1813 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Exhaust gas recirculation valve 2, B1, mass current: specified value VIRTUS_MQB_EGR_VALVE_2_B1_MASS_I_SPEC
- Service 22
DID 1814 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Generator voltage, actual VIRTUS_GEN_V_ACT
- Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2018 to 2026.
High pressure exhaust gas recirculation actuator, actual unconditioned voltage VIRTUS_HIGH_P_EGR_ACTUATOR_ACT_V
- Service 22
DID 11A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2018 to 2026.
High voltage battery energy information VIRTUS_HVBAT_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638 kWh
- Unit
- kWh
In testing for 2018 to 2026.
Ignition angle current cylinder VIRTUS_PQ35_IGN_ANG_CYL
- Service 22
DID 137A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 60 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Knock sensor voltage, cylinder 1 VIRTUS_KNOCK_SENS_V_CYL_1
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor voltage, cylinder 3 VIRTUS_KNOCK_SENS_V_CYL_3_7E0
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor voltage:, cylinder 2 VIRTUS_KNOCK_SENS_V_CYL_2
- Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor voltage:, cylinder 3 VIRTUS_KNOCK_SENS_V_CYL_3
- Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor voltage:, cylinder 5 VIRTUS_KNOCK_SENS_V_CYL_5
- Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensors average voltage bank 1,, variant 2 VIRTUS_KNOCK_SENSORS_AVG_V_1_2
- Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Maximum charge current VIRTUS_MAX_CHA_CUR_2
- Service 22
DID 1159 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Maximum discharge current VIRTUS_MAX_DCHA_CUR_2
- Service 22
DID 1158 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Start/stop battery target voltage VIRTUS_SSB_VTConfirmed
- Service 22
DID 2A00 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
0x26 = 38 → = 14.4 V
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Start/stop battery total charge VIRTUS_SSB_TOTAL_CHARGEConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x0000CB69 = 52073 → = 5,207.3 Ah
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Start/stop battery total discharge VIRTUS_SSB_TOTAL_DISCHARGEConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x0000C50D = 50445 → = 5,044.5 Ah
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Temperature sensor for engine temperature management voltage VIRTUS_T_SENS_ENG_T_V
- Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Turbocharger inlet pressure corrected value VIRTUS_TURBOCHARGER_INLET_P
- Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2018 to 2026.
Usable battery charge VIRTUS_USE_BAT_CHGConfirmed
- Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
0x1D = 29 → 29 Ah
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Climate
A/C compressor torque, requested VIRTUS_AC_COMP_TConfirmed
- Service 22
DID 1002 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Air conditioning compressor shutdown requirement VIRTUS_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT
- Service 22
DID 381A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Air conditioning compressor torque VIRTUS_PQ35_AC_COMP_TRQ
- Service 22
DID 104B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Ambient air temperature VIRTUS_AAT_7E0_7E0
- Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Ambient temperature VIRTUS_AAT_V2Confirmed
- Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255 to 255 °C
- Unit
- °C
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Barometric pressure VIRTUS_BARO
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Outside temperature VIRTUS_AAT_746Confirmed
- Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x9A = 154 → = 27 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap actual position VIRTUS_MQB_RECIRC_FLAP_ACTConfirmed
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0xC8 = 200 → = 100 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap fresh air threshold VIRTUS_MQB_RECIRC_FLAP_FRESH_THRConfirmed
- Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x004C = 76 → 76
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap target position VIRTUS_MQB_RECIRC_FLAP_TRGConfirmed
- Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0047 = 71 → 71
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap threshold VIRTUS_MQB_RECIRC_FLAP_THRConfirmed
- Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00C6 = 198 → 198
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Windshield temperature VIRTUS_WNDSHLD_TEMP
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -38.8 to 108.08 °C
- Unit
- °C
In testing for 2018 to 2023, 2025 to 2026. Not supported for 2024.
Clocks
Time since engine start VIRTUS_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x00D4 = 212 → 212 s
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Control
Accelerator pedal release detection threshold voltage VIRTUS_APP_REDUCE_V
- Service 22
DID 1029 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Air gab vacuum sensor VIRTUS_AIR_GAB_VACUUM_SNSConfirmed
- Service 22
DID 1816 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 32767
- Unit
- Raw value
0x003C = 60 → 60
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Brake booster pressure VIRTUS_BRAKE_BOOSTER_P
- Service 22
DID 11CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559
- Unit
- Raw value
In testing for 2018 to 2026.
Brake booster raw pressure VIRTUS_BRAKE_BOOSTER_RAW_P
- Service 22
DID 11D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Brake booster, actual vacuum VIRTUS_BRAKE_BOOSTER_ACT
- Service 22
DID 1490 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1279 to 1279
- Unit
- Raw value
In testing for 2018 to 2026.
Brake disk drying VIRTUS_BDD_ACTIVEConfirmed
- Service 22
DID 180E - Module
713 → 77D - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Brake disk drying, odometer at last activation VIRTUS_BDD_ODOConfirmed
- Service 22
DID 180E - Module
713 → 77D - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
0x0051A0 = 20896 → 20,896 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Brake pedal position VIRTUS_BRAKE_PEDAL_POS
- Service 22
DID 105D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Brake pressure VIRTUS_BRAKE_P
- Service 22
DID 105C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Brake pressure VIRTUS_BRAKE_P_713
- Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -543.8501 to 458.8288 bar
- Unit
- bar
In testing for 2018 to 2026.
Brake pressure VIRTUS_BRAKE_P_7E0
- Service 22
DID 195D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Brake pressure VIRTUS_MQB_TCM_BRAKE_P
- Service 22
DID 3803 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Brake pressure VIRTUS_PQ35_BRAKE_P
- Service 22
DID 18D0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Brake pressure sensor VIRTUS_BRAKE_P_SNSConfirmed
- Service 22
DID 1816 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 327.67 bar
- Unit
- bar
0x1081 = 4225 → = 42.25 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Brake system vacuum pump active VIRTUS_BRAKE_SYSTEM_VACUUM
- Service 22
DID 395E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Downshift point adaptation voltage VIRTUS_DOWNSHIFT_ADAPT_V
- Service 22
DID 1028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Electronic differential lock: active VIRTUS_EDL_ACTIVEConfirmed
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Electronic differential lock: front left brake temperature VIRTUS_EDL_FR_L_BRAKE_TConfirmed
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Electronic differential lock: front right brake temperature VIRTUS_EDL_FR_R_BRAKE_TConfirmed
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Bits 24 to 39 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Electronic differential lock: rear left brake temperature VIRTUS_EDL_RR_L_BRAKE_TConfirmed
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Bits 40 to 55 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Electronic differential lock: rear right brake temperature VIRTUS_EDL_RR_R_BRAKE_TConfirmed
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Hydraulic brake booster: active VIRTUS_HYD_BRAKE_BOOST_ACTIVEConfirmed
- Service 22
DID 1810 - Module
713 → 77D - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Pressure in brake servo unit VIRTUS_P_BRAKE_SERVO_UNIT
- Service 22
DID 2005 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375
- Unit
- Raw value
In testing for 2018 to 2026.
Requested brake torque, auxiliary system VIRTUS_REQ_BRAKE_TQ
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Drivetrain
Driver torque requested #1 VIRTUS_ENG_TRQ_REQ_1
- Service 22
DID 29D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Driver torque requested #2 VIRTUS_ENG_TRQ_REQ_2
- Service 22
DID 4380 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024.
Distance traveled since diagnostic trouble codes cleared VIRTUS_CLR_DISTConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x733D = 29501 → 29,501 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Distance traveled while mil was activated VIRTUS_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Number of warm-ups since diagnostic trouble codes cleared VIRTUS_WARM_UPSConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
ECU
Misfires, cylinder 2 VIRTUS_MISFIRES__CYL__2Confirmed
- Service 22
DID 1152 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x08FB = 2299 → 2,299
Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.
Misfires, cylinder 4 VIRTUS_MISFIRES__CYL__4Confirmed
- Service 22
DID 1151 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0B63 = 2915 → 2,915
Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.
Torque converter slip VIRTUS_TORQUE_CONVERTER_SLIP
- Service 22
DID 2131 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Engine
A/C compressor load VIRTUS_CLIMATE_A_C_COMP_LOADConfirmed
- Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 N·m
- Unit
- N·m
0x62 = 98 → = 9.8 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Actual turbo boost VIRTUS_ACT_TURBO_BOOST
- Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2 bar
- Unit
- bar
In testing for 2018 to 2026.
Adaptation of loss torque VIRTUS_ADPT_LOSS_TQ
- Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Adaptation of throttle valve VIRTUS_ADPT_THROTTLE_VLV
- Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder1 fast diagnosis VIRTUS_ADPT_VAL_CYL1_FAST
- Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder1 slow diagnosis VIRTUS_ADPT_VAL_CYL1_SLOW
- Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder2 fast diagnosis VIRTUS_ADPT_VAL_CYL2_FAST
- Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder2 slow diagnosis VIRTUS_ADPT_VAL_CYL2_SLOW
- Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder3 fast diagnosis VIRTUS_ADPT_VAL_CYL3_FAST
- Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder3 slow diagnosis VIRTUS_ADPT_VAL_CYL3_SLOW
- Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder4 fast diagnosis VIRTUS_ADPT_VAL_CYL4_FAST
- Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptation val.cylinder4 slow diagnosis VIRTUS_ADPT_VAL_CYL4_SLOW
- Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2018 to 2026.
Adaptive mode VIRTUS_ADAPTIVE_MODE
- Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Air conditioning compressor pressure VIRTUS_AC_COMP_P
- Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2018 to 2026.
Air conditioning compressor pressure, linear raw value VIRTUS_AC_COMP_P_LINEAR_RAW
- Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2018 to 2026.
Air conditioning compressor refrigerant pressure VIRTUS_AC_COMP_REFRIGERANT_P
- Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2018 to 2026.
Air conditioning compressor torque VIRTUS_AC_COMP_TQ
- Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Air conditioning compressor torque VIRTUS_AC_COMP_TQ_7E0
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Air conditioning compressor torque VIRTUS_AC_COMP_TQ_REQ
- Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Air conditioning refrigerant pressure VIRTUS_AC_REFRIGERANT_P
- Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2018 to 2026.
Air filling VIRTUS_AIR_FILLING
- Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Air leakage VIRTUS_AIR_LEAKAGE
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Air mass meter 1 VIRTUS_MQB_AIR_MASS_1
- Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Air mass, actual value, mg/stroke VIRTUS_AIR_MASS_ACT_MG
- Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Alternator load VIRTUS_ALTERNATOR_LOAD
- Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Ambient air pressure VIRTUS_AMBIENT_AIR_P
- Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14
- Unit
- Raw value
In testing for 2018 to 2026.
Ambient air temperature, v1 VIRTUS_AAT_V1
- Service 22
DID 14F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2018 to 2026.
Ambient temperature VIRTUS_AAT_7E0
- Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2018 to 2026.
Ambient temperature VIRTUS_AAT_7E0_2
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Analysis, clutch 1, maximum temperature VIRTUS_ANALYSIS_CLU_1_MAX_T
- Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Analysis, clutch 2, maximum temperature VIRTUS_ANALYSIS_CLU_2_MAX_T
- Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Automatic transmission fluid temperature, lifetime max VIRTUS_ATF_MAX
- Service 22
DID 704F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018 to 2026.
Aux. hydraulic pump internal temperature VIRTUS_AUX_HYDRAULIC_PMP_T
- Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Aux. hydraulic pump, current VIRTUS_AUX_HYDRAULIC_PMP
- Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 2018 to 2026.
Average ignition timing angle delay adjustment VIRTUS_AVG_IGN_TIM_ANG
- Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Avg. injection time VIRTUS_AVG_INJ_TIME
- Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1717986 ms
- Unit
- ms
In testing for 2018 to 2026.
Avg. injection time, variant 2 VIRTUS_AVG_INJ_TIME_VAR_2
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2018 to 2026.
Basic correction factor:, cylinder 1, filtered VIRTUS_BASIC_CORR_FACTOR_1
- Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 2, filtered VIRTUS_BASIC_CORR_FACTOR_2
- Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 3, filtered VIRTUS_BASIC_CORR_FACTOR_3
- Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 4, filtered VIRTUS_BASIC_CORR_FACTOR_4
- Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Boost press before throttle: calculated actual value VIRTUS_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT
- Service 22
DID 181A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -81920000 to 81917500
- Unit
- Raw value
In testing for 2018 to 2026.
Boost pressure actuator, commanded duty VIRTUS_BOOST_P_ACTUATOR_CMD
- Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Boost pressure, actual VIRTUS_BOOST_P_ACT_7E0
- Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242
- Unit
- Raw value
In testing for 2018 to 2026.
Boost pressure, target VIRTUS_BOOST_P_TGT
- Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550
- Unit
- Raw value
In testing for 2018 to 2026.
Boost regulation duty, commanded value VIRTUS_BOOST_REGULATION_CMD
- Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Boost regulator feedback VIRTUS_BOOST_REGULATOR_FEEDBACK
- Service 22
DID 11CC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Bypass valve high pressure turbine inlet, activation VIRTUS_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, actual value VIRTUS_BYPASS_VLV_HIGH_P_ACT
- Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, offset closed VIRTUS_BYPASS_VLV_HIGH_P
- Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, offset open VIRTUS_BYPASS_VLV_HIGH_P_TURBINE
- Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, target value VIRTUS_BYPASS_VLV_HIGH_P_TGT
- Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bze_q_elad VIRTUS_BZE_Q_ELAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Bze_q_lad VIRTUS_BZE_Q_LAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Cabin temperature VIRTUS_CABIN_TConfirmed
- Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0150 = 336 → = 33.6 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Calculated oil temperature VIRTUS_PQ35_CALCULATED_OIL_T
- Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Camshaft adaptation exhaust bank 1, phase position VIRTUS_CAM_ADPT_EXH_BANK_1_PHASE
- Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation intake bank 1, activation VIRTUS_CAM_ADPT_INT_BANK_1_ACTIVATION
- Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Camshaft adaptation intake bank 1, actual value VIRTUS_CAM_ADPT_INT_BANK_1_ACT
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation intake bank 1, phase position VIRTUS_CAM_ADPT_INT_BANK_1_PHASE
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation intake bank 1, specified value VIRTUS_CAM_ADPT_INT_BANK_1_SPEC
- Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation intake, phase position VIRTUS_CAM_ADPT_INT_PHASE
- Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, exhaust bank 1, phase position VIRTUS_CAM_ADPT_EXH_BANK_1
- Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, intake bank 1, phase position VIRTUS_CAM_ADPT_INT_BANK_1
- Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, intake deviation VIRTUS_CAM_ADPT_INT_DEV
- Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment intake test bank 1 VIRTUS_CAM_ADJ_INT_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Camshaft adjustment outlet test bank 1 VIRTUS_CAM_ADJ_OUTLET_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 1, actual value VIRTUS_CAM_ADJ_EXH_BANK_1_ACT
- Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 1, specified value VIRTUS_CAM_ADJ_EXH_BANK_1_SPEC
- Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 2, actual value VIRTUS_CAM_ADJ_EXH_BANK_2_ACT
- Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 2, specified value VIRTUS_CAM_ADJ_EXH_BANK_2_SPEC
- Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262 to 262 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust, activation VIRTUS_CAM_ADJ_EXH
- Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Camshaft adjustment, exhaust, specified value VIRTUS_CAM_ADJ_EXH_SPEC
- Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake bank 1, actual value VIRTUS_CAM_ADJ_INT_BANK_1_ACT
- Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake bank 1, specified value VIRTUS_CAM_ADJ_INT_BANK_1_SPEC
- Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft end position VIRTUS_PQ35_CAMS_END
- Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft position, deviation from the base position VIRTUS_CAM_POS_DEV_BASE_POS
- Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft start position VIRTUS_PQ35_CAMS_START
- Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2018 to 2026.
Cat. converter oxygen storage capacity measured VIRTUS_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_7E0
- Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Cat. temperature, bank 1 VIRTUS_CAT_T_BANK_1
- Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2018 to 2026.
Cat. temperature, bank 2 VIRTUS_CAT_T_BANK_2
- Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2018 to 2026.
Catalyst temperature, calculated VIRTUS_CAT_T_CALC
- Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2018 to 2026.
Centrifugal oil temperature VIRTUS_PQ35_CENTRIFUGAL_OIL_T
- Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2018 to 2026.
Chain elongation inlet, mileage at last adaptation VIRTUS_CHAIN_ELONGATION_INLET
- Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2018 to 2026.
Chain elongation outlet, mileage at last adaptation VIRTUS_CHAIN_ELONGATION
- Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2018 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 VIRTUS_CHAIN_ELONGATION_NO_VALID_1
- Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Chain elongation, no of valid initial values, intake bank 1 VIRTUS_CHAIN_ELONGATION_NO_1
- Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Clutch #1 maximum temperature VIRTUS_PQ35_CLUTCH_1_MAXIMUM_T
- Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch #2 maximum temperature VIRTUS_PQ35_CLUTCH_2_MAXIMUM_T
- Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch 0 temperature calculated VIRTUS_MQB_DL382_CLUTCH_0_T_CALCULATED
- Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch 1 temperature VIRTUS_PQ35_CLUTCH_1_T
- Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch 1 temperature protection overheat protection 1 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Service 22
DID 3881 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 1 temperature protection warning 1 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY
- Service 22
DID 387F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 1 temperature protection warning 2 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY
- Service 22
DID 3880 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 temperature VIRTUS_PQ35_CLUTCH_2_T
- Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch 2 temperature protection overheat protection 1 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Service 22
DID 3885 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 temperature protection warning 1 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY
- Service 22
DID 3883 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 temperature protection warning 2 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY
- Service 22
DID 3884 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch center central plate temperature VIRTUS_CLU_CENTER_CENTRAL_T
- Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Clutch temperature calculated VIRTUS_MQB_DL382_CLUTCH_T_CALCULATED
- Service 22
DID 18E3 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Commanded crankshaft torque VIRTUS_CMD_CRANK_TQ
- Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Compression test cylinder 1 VIRTUS_PQ35_COMPRESSION_TEST_CYL_1
- Service 22
DID 1129 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test cylinder 2 VIRTUS_PQ35_COMP_TEST_CYL_2
- Service 22
DID 112A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test cylinder 3 VIRTUS_PQ35_COMP_TEST_CYL_3
- Service 22
DID 112B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test, cylinder 1 VIRTUS_COMPRESSION_TEST_CYL_1
- Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test, cylinder 2 VIRTUS_COMPRESSION_TEST_CYL_2
- Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test, cylinder 3 VIRTUS_COMPRESSION_TEST_CYL_3
- Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compression test, cylinder 4 VIRTUS_COMPRESSION_TEST_CYL_4
- Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Control module temperature VIRTUS_CTRL_MODULE_T
- Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Converter loss torque VIRTUS_MQB_TCM_CONVERTER_LOSS_TORQUE
- Service 22
DID 1010 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Coolant at engine start VIRTUS_CLT_ENG_START
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant circulation pump, activation VIRTUS_CLT_CIRCULATION_PMP_ACTIVATION
- Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant circulation pump, control VIRTUS_CLT_CIRCULATION_PMP
- Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1 activation, $1117 VIRTUS_CLT_FAN_1_ACTIVATION_1117
- Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1 duty cycle VIRTUS_PQ35_COOL_FAN_1_DUTY
- Service 22
DID 1116 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1, activation VIRTUS_CLT_FAN_1_ACTIVATION
- Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1, commanded duty VIRTUS_CLT_FAN_1_CMD_DUTY
- Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 2 duty cycle VIRTUS_PQ35_COOL_FAN_2_DUTY
- Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 2, activation VIRTUS_CLT_FAN_2_ACTIVATION
- Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan, requested by A/C VIRTUS_CLT_FAN_REQ_AC
- Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant shut-off valve, closed VIRTUS_CLT_SHUT_OFF_VLV
- Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2018 to 2026.
Coolant temperature at engine outlet, calculated VIRTUS_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_7E0
- Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at engine outlet, calculated VIRTUS_ECT_ENG_OUTLET_CALC
- Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at engine start VIRTUS_ECT_ENG_START
- Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet VIRTUS_COOLANT_T
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet VIRTUS_ECT_RADIATOR_OUTLET
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet 2 VIRTUS_ECT_RAD_OUT_2
- Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet v.1 VIRTUS_ECT_RADIATOR_OUTLET_V_1
- Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet v.3 VIRTUS_ECT_RADIATOR_OUTLET_V_3
- Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet, actual value VIRTUS_ECT_RADIATOR_OUTLET_ACT_7E0
- Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet, specified value VIRTUS_ECT_RADIATOR_OUTLET_SPEC
- Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature difference between engine and radiator VIRTUS_ECT_DIFF_ENG
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature linear VIRTUS_ECT_LINEAR
- Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature modeled value VIRTUS_ECT_MODELED
- Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature, maximum value VIRTUS_ECT_MAX
- Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature, minimum value VIRTUS_ECT_MIN
- Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Correction factor of oil temperature for engine protection VIRTUS_CORR_FACTOR_OIL_T
- Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99
- Unit
- Number
In testing for 2018 to 2026.
Correction values for main pressure adaptation VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT
- Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Counter steer support VIRTUS_CNT_STEER_SUPPORT_ACTIVEConfirmed
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Counter steer support, steering torque VIRTUS_CNT_STEER_SUPPORT_STEERING_TRQConfirmed
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Crankshaft rotation angle when closing the quantity control valve VIRTUS_CRANK_ROT_ANG
- Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 0 VIRTUS_CTR_MIS_DC_MMV_CYL_0
- Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 VIRTUS_CTR_MIS_DC_MMV_CYL_1
- Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 VIRTUS_CTR_MIS_DC_MMV_CYL_2
- Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Current N215 pressure control valve 1 VIRTUS_CURRENT_N215_P_CTRL_1
- Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current N216 pressure control valve 2 VIRTUS_CURRENT_N216_P_CTRL_2
- Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current N217 pressure control valve 3 VIRTUS_CURRENT_N217_P_CTRL_3
- Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current N218 pressure control valve 4 VIRTUS_CURRENT_N218_P_CTRL_4
- Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current N233 pressure control valve 5 VIRTUS_CURRENT_N233_P_CTRL_5
- Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current solenoid VIRTUS_CURRENT_SOLENOID
- Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current type of driver counter VIRTUS_CURRENT_TYPE_DRIVER
- Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Cylinder 1 internal torque VIRTUS_CYL_1_INTERNAL_TQ
- Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Cylinder 2 internal torque VIRTUS_CYL_2_INTERNAL_TQ
- Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Cylinder 3 internal torque VIRTUS_CYL_3_INTERNAL_TQ
- Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Cylinder 4 internal torque VIRTUS_CYL_4_INTERNAL_TQ
- Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Cylinder block temperature sensor VIRTUS_CYL_BLOCK_T_SENS
- Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Cylinder head temperature VIRTUS_CYL_HEAD_T
- Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2018 to 2026.
Desired torque raw VIRTUS_DES_TQ_RAW
- Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Differential pressure VIRTUS_PQ35_DIFF_P
- Service 22
DID 14F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Direct injections counter VIRTUS_DIRECT_INJECTIONS
- Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2018 to 2026.
Drive motor current VIRTUS_MOTOR_I
- Service 22
DID 147D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2018 to 2026.
Drive motor torque VIRTUS_MOTOR_TQ
- Service 22
DID 147F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -10922.666 to 10922.333 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Driver demand torque VIRTUS_MQB_TCM_DRIVER_DEMAND_TORQUE
- Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Driving mode sensor, hall sensor a VIRTUS_DRIVING_MODE_SENS
- Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Driving position VIRTUS_DRIVING_POS
- Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Driving resistance index VIRTUS_DRIVING_RES_INDEX
- Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2018 to 2026.
Dynamic average of ignition angle delay adjustment VIRTUS_DYNAMIC_AVG_IGN_ANG
- Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 0 VIRTUS_EA888B_BOOST_P_CTRL_0
- Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 1 VIRTUS_EA888B_BOOST_P_CTRL_1
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 2 VIRTUS_EA888B_BOOST_P_CTRL_2
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 3 VIRTUS_EA888B_BOOST_P_CTRL_3
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure regulator, commanded VIRTUS_EA888B_BOOST_P_CMD
- Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Early ignition counter for toque reduction, cylinder 1 VIRTUS_EARLY_IGN_CNT_TOQUE_1
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for toque reduction, cylinder 2 VIRTUS_EARLY_IGN_CNT_TOQUE_2
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for toque reduction, cylinder 3 VIRTUS_EARLY_IGN_CNT_TOQUE_3
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for toque reduction, cylinder 4 VIRTUS_EARLY_IGN_CNT_TOQUE_4
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_1
- Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_2
- Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_3
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_4
- Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 1 VIRTUS_EARLY_IGN_CNT_TOT_1
- Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 2 VIRTUS_EARLY_IGN_CNT_TOT_2
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 3 VIRTUS_EARLY_IGN_CNT_TOT_3
- Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 4 VIRTUS_EARLY_IGN_CNT_TOT_4
- Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Effective injection duration VIRTUS_EFFECTIVE_INJ_DUR
- Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2018 to 2026.
EGT after catalyst, model bank b VIRTUS_EGT_AFTER_CAT_MODEL_B
- Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2018 to 2026.
EGT after catalyst, modeled VIRTUS_EGT_AFTER_CAT
- Service 22
DID 1272 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
EGT at lambda sensor 1, modeled VIRTUS_EGT_LAMBDA_SENS_1
- Service 22
DID 139C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Electric additional coolant pump control, high circle VIRTUS_ELEC_ADDITIONAL_CLT
- Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Energy balance of last driving cycle VIRTUS_ENERGY_BALANCE_LAST
- Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Energy content VIRTUS_ENERGY_CONTENT
- Service 22
DID 22E4 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2018 to 2026.
Engine air mass, specified value VIRTUS_ENG_AIR_MASS_SPEC
- Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Engine compartment temperature raw value VIRTUS_ENG_COMPARTMENT_T
- Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine control module temperature VIRTUS_ENG_CTRL_MODULE_TConfirmed
- Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
0x0C3C = 3132 → = 40.1 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Engine control unit temperature VIRTUS_MQB_TCM_ECU_T
- Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine drag torque VIRTUS_ENG_DRAG_TQ
- Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine oil level VIRTUS_ENG_OIL_LEVEL_7E0
- Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 2018 to 2026.
Engine oil level VIRTUS_PQ35_OIL_LVL
- Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2018 to 2026.
Engine oil level current value VIRTUS_ENG_OIL_LEVEL
- Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine oil pressure VIRTUS_EOP
- Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 157 psi
- Unit
- psi
In testing for 2018 to 2026.
Engine oil sump temperature VIRTUS_ENG_OIL_SUMP_T
- Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2018 to 2026.
Engine oil temperature VIRTUS_EOT_7E0_7E0
- Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature measured value VIRTUS_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature, calculated VIRTUS_EOT_CALC
- Service 22
DID 201A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature, engine control module VIRTUS_EOT_ECMConfirmed
- Service 22
DID 11BD - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
0x0BB0 = 2992 → = 26.1 °C
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Engine oil temperature, pulse sensor VIRTUS_EOT_PULS
- Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature, variant 3 VIRTUS_EOT_VAR_3
- Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature, variant 4 VIRTUS_EOT_VAR_4
- Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine outlet coolant temperature calculated VIRTUS_ENG_OUTLET_ECT_CALC
- Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine protection, torque limit VIRTUS_ENG_PROTECTION_TQ
- Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine radiator fan request VIRTUS_ENG_RADIATOR_FAN_REQ
- Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine start quantity VIRTUS_PQ35_ENG_START_QTY
- Service 22
DID 1069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Engine temperature control actuator VIRTUS_ENG_T_CTRL_ACTUATOR
- Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, after-run stop VIRTUS_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine temperature management actuator, duty cycle activation VIRTUS_ENG_T_MANAGEMENT_ACTUATOR
- Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, raw value VIRTUS_ENG_T_MANAGEMENT
- Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine temperature management actuator, specified value VIRTUS_ENG_T_MANAGEMENT_SPEC
- Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, stop open VIRTUS_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine torque VIRTUS_ENG_TQ
- Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_ENG_TQ_7E0
- Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_ENG_TQ_7E0_7E0
- Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_ENG_TQ_7E1
- Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_MQB_TCM_ENG_TORQUE
- Service 22
DID 7064 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_MQB_TCM_ENGINE_TORQUE
- Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_PQ35_ENG_TORQUE
- Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque VIRTUS_PQ35_ENG_TRQ
- Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque limitation VIRTUS_ENG_TQ_LIM
- Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque limitation VIRTUS_MQB_TCM_ENGINE_TORQUE_LIMITATION
- Service 22
DID 100E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque loss VIRTUS_MQB_TCM_ENGINE_TORQUE_LOSS
- Service 22
DID 100F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Environment data camshaft input 1 VIRTUS_PQ35_ENVD_CAM_IN_1
- Service 22
DID 1213 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Excessive temperature protection VIRTUS_EXCESSIVE_T
- Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Exhaust camshaft, adaptation bias VIRTUS_EXH_CAM_ADPT_BIAS
- Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Exhaust camshaft, adaptation sensor tolerance VIRTUS_EXH_CAM_ADPT_SENS
- Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Exhaust gas jet volume in particle filter VIRTUS_EXH_GAS_JET_VOLUME
- Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 L
- Unit
- L
In testing for 2018 to 2026.
Exhaust gas recirculation valve 2 bank 1 mass flow VIRTUS_MQB_EGR_VALVE_2_B1_FLOW
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Exhaust gas recirculation valve duty VIRTUS_PQ35_EGR_DUTY
- Service 22
DID 10C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Exhaust gas temperature VIRTUS_EXH_GAS_T
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature - calculated after catalyst VIRTUS_EXH_GAS_T_CALC_AFTER
- Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature before catalyst VIRTUS_EXHAUST_GAS_T_BEFORE_CATALYST
- Service 22
DID 1282 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -193.93 to 1116.77 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature before catalytic converter VIRTUS_EXH_GAS_T_BEFORE
- Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature sensor 1 VIRTUS_EXH_GAS_T_SENS_1
- Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature sensor 1 VIRTUS_PQ35_EXH_GAS_T_1
- Service 22
DID 10FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature sensor 2 VIRTUS_PQ35_EXHAUST_GAS_T_SENSOR_2
- Service 22
DID 14F7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature sensor 4 VIRTUS_EXH_GAS_T_SENS_4
- Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature, sensor 4, bank 2 VIRTUS_EXH_GAS_T_S4_B2
- Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust temperature before the catalyst, modeled VIRTUS_EXH_T_BEFORE_CAT
- Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust temperature control downstream oxidation catalyst filtered model error VIRTUS_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR
- Service 22
DID 1AD7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Field limit value VIRTUS_PQ35_FIELD_LIM
- Service 22
DID 11F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Field regeneration request status VIRTUS_FIELD_REGEN_REQ_STAT
- Service 22
DID 2087 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Front left deflector temperature VIRTUS_CLIMATE_FR_L_DEFL_TConfirmed
- Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x70 = 112 → = 37.296 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front right deflector temperature VIRTUS_CLIMATE_FR_R_DEFL_TConfirmed
- Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x70 = 112 → = 37.296 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Fuel temperature VIRTUS_PQ35_FUEL_T
- Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Generator current VIRTUS_GEN_CURRENT
- Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2018 to 2026.
Generator load normalized value VIRTUS_GENERATOR_LOAD_NORMALIZED_VALUE_7E0
- Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Generator load signal VIRTUS_GEN_LOAD_SIG
- Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Generator load signal VIRTUS_GEN_LOAD_SIG_7E0
- Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Generator power VIRTUS_GEN_POWER
- Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 617647.7145 W
- Unit
- W
In testing for 2018 to 2026.
Generator torque request VIRTUS_GENERATOR_TORQUE_REQUEST_7E0
- Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Heater circulation pump, nominal value VIRTUS_HEATER_CIRCULATION
- Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Heater support pump, specified value VIRTUS_HEATER_SUPPORT_PMP_SPEC
- Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Height correction VIRTUS_HEIGHT_CORR
- Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2018 to 2026.
High pressure control, adaptation VIRTUS_HIGH_P_CTRL_ADPT
- Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2018 to 2026.
High pressure EGR actuator, activation VIRTUS_HIGH_P_EGR_ACTUATOR
- Service 22
DID 1334 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
High pressure regulation, adaptation value VIRTUS_HIGH_P_REGULATION
- Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Hybrid temperature VIRTUS_MQB_TCM_HYBRID_T
- Service 22
DID 1196 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2018 to 2026.
ID of current driving program VIRTUS_ID_CURRENT_DRIVING
- Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
IGA_CYL_KNK, 0 VIRTUS_IGA_CYL_KNK_0
- Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 1 VIRTUS_IGA_CYL_KNK_1
- Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 2 VIRTUS_IGA_CYL_KNK_2
- Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 3 VIRTUS_IGA_CYL_KNK_3
- Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 0 VIRTUS_IGA_IGC_0
- Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 1 VIRTUS_IGA_IGC_1
- Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 2 VIRTUS_IGA_IGC_2
- Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 3 VIRTUS_IGA_IGC_3
- Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
Ignition angle current cylinder, actual value VIRTUS_IGN_ANG_CURRENT_CYL_ACT
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -25 to 25 °
- Unit
- °
In testing for 2018 to 2026.
Injection amount deviation cylinder 1 VIRTUS_INJ_AMOUNT_DEV_CYL_1
- Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 1 VIRTUS_PQ35_INJ_DEV_CYL_1
- Service 22
DID 10FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 2 VIRTUS_INJ_AMOUNT_DEV_CYL_2
- Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 2 VIRTUS_PQ35_INJ_DEV_CYL_2
- Service 22
DID 1105 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 3 VIRTUS_INJ_AMOUNT_DEV_CYL_3
- Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 3 VIRTUS_PQ35_INJ_DEV_CYL_3
- Service 22
DID 1100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 4 VIRTUS_INJ_AMOUNT_DEV_CYL_4
- Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2018 to 2026.
Injection amount deviation cylinder 4 VIRTUS_PQ35_INJ_DEV_CYL_4
- Service 22
DID 1104 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Injection quantity deviation, cylinder 2 VIRTUS_INJ_QTY_DEV_CYL_2
- Service 22
DID 204A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Injection quantity deviation, cylinder 5 VIRTUS_INJ_QTY_DEV_CYL_5
- Service 22
DID 204B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Injector 1 rail pressure calibration point 1 VIRTUS_PQ35_INJ_1_RAIL_P_1
- Service 22
DID 10D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 1 rail pressure calibration point 2 VIRTUS_PQ35_INJ_1_RAIL_P_2
- Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 1 rail pressure calibration point 3 VIRTUS_PQ35_INJ_1_RAIL_P_3
- Service 22
DID 10DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 2 rail pressure calibration point 1 VIRTUS_PQ35_INJ_2_RAIL_P_1
- Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 2 rail pressure calibration point 2 VIRTUS_PQ35_INJ_2_RAIL_P_2
- Service 22
DID 10D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 2 rail pressure calibration point 3 VIRTUS_PQ35_INJ_2_RAIL_P_3
- Service 22
DID 10DF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 2: rail pressure calibration point 1 VIRTUS_INJ_2_RAIL_P_CAL_PT_1_146E
- Service 22
DID 146E - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Injector 2: rail pressure calibration point 2 VIRTUS_INJ_2_RAIL_P_CAL_PT_2_1474
- Service 22
DID 1474 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Injector 2: rail pressure calibration point 3 VIRTUS_INJ_2_RAIL_P_CAL_PT_3_147A
- Service 22
DID 147A - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Injector 3 rail pressure calibration point 1 VIRTUS_PQ35_INJ_3_RAIL_P_1
- Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 3 rail pressure calibration point 2 VIRTUS_PQ35_INJ_3_RAIL_P_2
- Service 22
DID 10D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 3 rail pressure calibration point 3 VIRTUS_PQ35_INJ_3_RAIL_P_3
- Service 22
DID 10DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 4 rail pressure calibration point 2 VIRTUS_PQ35_INJ_4_RAIL_P_2
- Service 22
DID 10D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 4 rail pressure calibration point 3 VIRTUS_PQ35_INJ_4_RAIL_P_3
- Service 22
DID 10DE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2018 to 2026.
Injector 7: rail pressure calibration point 1 VIRTUS_INJ_7_RAIL_P_CAL_PT_1
- Service 22
DID 146D - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Injector 7: rail pressure calibration point 2 VIRTUS_INJ_7_RAIL_P_CAL_PT_2
- Service 22
DID 1473 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Injector 7: rail pressure calibration point 3 VIRTUS_INJ_7_RAIL_P_CAL_PT_3
- Service 22
DID 1479 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Inlet flaps - actual value VIRTUS_INLET_FLAPS_ACT
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Inlet flaps - requested value VIRTUS_INLET_FLAPS_REQ
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake air temperature VIRTUS_IAT_7E0
- Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake air temperature before throttle valve, raw value VIRTUS_IAT_BEFORE_THROTTLE
- Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake air temperature in intake manifold VIRTUS_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_7E0
- Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake air temperature in intake manifold raw value VIRTUS_IAT_INT_MANIFOLD_RAW
- Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake camshaft adaptation unit 1 phase length VIRTUS_PQ35_CAMS_ADAPT_PHASE_1
- Service 22
DID 12FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 2 VIRTUS_PQ35_CAMS_EDGE_POS_2
- Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 3 VIRTUS_PQ35_CAMS_EDGE_POS_3
- Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 4 VIRTUS_PQ35_CAMS_EDGE_POS_4
- Service 22
DID 118B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 5 VIRTUS_PQ35_CAMS_EDGE_POS_5
- Service 22
DID 118C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 6 VIRTUS_PQ35_CAMS_EDGE_POS_6
- Service 22
DID 118D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 7 VIRTUS_PQ35_CAMS_EDGE_POS_7
- Service 22
DID 118E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted edge 8 VIRTUS_PQ35_CAMS_EDGE_POS_8
- Service 22
DID 118F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft signal edge position adapted value edge 1 VIRTUS_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1
- Service 22
DID 173A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft, adaptation bias VIRTUS_INT_CAM_ADPT_BIAS
- Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft, adaptation sensor tolerance VIRTUS_INT_CAM_ADPT_SENS
- Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Intake manifold pressure calculated VIRTUS_MQB_INT_MAN_P
- Service 22
DID 103C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold pressure raw value VIRTUS_INT_MANIFOLD_P_RAW
- Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.92
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold pressure raw value VIRTUS_INT_MANIFOLD_P_RAW_7E0
- Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Intake manifold pressure, commanded VIRTUS_INT_MANIFOLD_P_CMD
- Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold pressure, corrected VIRTUS_INT_MANIFOLD_P
- Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold runner control, acknowledgment VIRTUS_INT_MANIFOLD_RUNNER_CTRL
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake manifold runner control, activation VIRTUS_INT_MANIFOLD_RUNNER
- Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake model air mass flow filtered value VIRTUS_INT_MODEL_AIR_MASS
- Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Intake phase deviation, actual value VIRTUS_INT_PHASE_DEV_ACT
- Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
Integrated mass of air since engine start VIRTUS_INTEGRATED_MASS_AIR
- Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2018 to 2026.
Integrated mass of air since the first engine start VIRTUS_INTEGRATED_MASS_AIR_SINCE
- Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2018 to 2026.
Intercooler air output temperature VIRTUS_PQ35_INTERCOOLER_AIR_OUTPUT_T
- Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Kick down VIRTUS_MQB_TCM_KICK_DOWN
- Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Kilometers driven since last event on K1 VIRTUS_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1
- Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 2018 to 2026.
Kilometers driven since last event on K2 VIRTUS_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2
- Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 2018 to 2026.
Knock retard 2 VIRTUS_KNOCK_RETARD_2
- Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2026.
Knock retard 2,, variant 1 VIRTUS_KNOCK_RETARD_2_VAR_1
- Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2026.
Knock sensor 1 test VIRTUS_KNOCK_SENS_1_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 2 test VIRTUS_KNOCK_SENS_2_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 3 test VIRTUS_KNOCK_SENS_3_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 4 test VIRTUS_KNOCK_SENS_4_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor based camshaft angle adjustment counter VIRTUS_KNOCK_CAM_ANG_ADJ
- Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Knock sensor, cylinder 1 VIRTUS_KNOCK_SENS_CYL_1
- Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 317 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 1, variant 2 VIRTUS_KNOCK_SENS_CYL_1_VAR_2
- Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 2 VIRTUS_KNOCK_SENS_CYL_2
- Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 317 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 2 VIRTUS_KNOCK_SENS_CYL_2_7E0
- Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3272
- Unit
- Number
In testing for 2018 to 2026.
Knock sensor, cylinder 2, variant 2 VIRTUS_KNOCK_SENS_CYL_2_VAR_2
- Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 3 VIRTUS_KNOCK_SENS_CYL_3
- Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 317 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 3, variant 2 VIRTUS_KNOCK_SENS_CYL_3_VAR_2
- Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 4 VIRTUS_KNOCK_SENS_CYL_4
- Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 317 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 4, variant 2 VIRTUS_KNOCK_SENS_CYL_4_VAR_2
- Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Lambda output value VIRTUS_LAMBDA_OUTPUT
- Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2018 to 2026.
Lambda, actual value VIRTUS_LAMBDA_ACT
- Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.9999 to 7.9997
- Unit
- Number
In testing for 2018 to 2026.
Launch control counter, variant 1 VIRTUS_LAUNCH_CTRL_CNT_VAR_1
- Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Launch control counter, variant 2 VIRTUS_LAUNCH_CTRL_CNT_VAR_2
- Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Leg deflector temperature VIRTUS_CLIMATE_LEG_DEFL_TConfirmed
- Service 22
DID 2611 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x78 = 120 → = 39.96 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Long term fuel trim at idle, direct injection VIRTUS_LONG_TERM_FUEL_TRIM_IDLE
- Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Long term fuel trim at idle, port injection VIRTUS_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Long term throttle adaptation to MAF sensor VIRTUS_LONG_TERM_THROTTLE
- Service 22
DID 113A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.99 %
- Unit
- %
In testing for 2018 to 2026.
Long-term adaptation of intake manifold injection VIRTUS_LONG_TERM_ADPT_INT
- Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Long-term adaptation of intake manifold injection at idle VIRTUS_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Lost torque adaptation A/C + driving mode VIRTUS_LOST_TQ_ADPT_AC
- Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Lost torque adaptation driving mode VIRTUS_LOST_TQ_ADPT_DRIVING
- Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Low press. EGR closing VIRTUS_LOW_PRESS_EGR
- Service 22
DID 406B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Low pressure EGR closing VIRTUS_LOW_P_EGR_CLOSING
- Service 22
DID 17F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -699 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Lower adapted coupling point K2 from micro-slip path adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT
- Service 22
DID 110A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
M009, desired solenoid out 10 VIRTUS_M009_DES_SOLENOID_10
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
M009, desired solenoid out 11 VIRTUS_M009_DES_SOLENOID_11
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
M009, desired solenoid out 12 VIRTUS_M009_DES_SOLENOID_12
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
M009, desired solenoid out 13 VIRTUS_M009_DES_SOLENOID_13
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
M009, desired solenoid out 14 VIRTUS_M009_DES_SOLENOID_14
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Main catalyst aging factor VIRTUS_MAIN_CAT_AGING
- Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.199
- Unit
- Number
In testing for 2018 to 2026.
Main injection duration VIRTUS_PQ35_MAIN_INJ_DURATION
- Service 22
DID 14CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Main injection start position VIRTUS_PQ35_MAIN_INJ_START
- Service 22
DID 11F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Mass air flow over throttle valve VIRTUS_MAF_OVER_THROTTLE
- Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mass air flow rate VIRTUS_MAF_RATE
- Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2018 to 2026.
Mass air flow through throttle VIRTUS_MAF_THROUGH_THROTTLE
- Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Mass air flow, commanded VIRTUS_MAF_CMD
- Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Mass airflow sensor 1 bank 1 raw value VIRTUS_MQB_MAF_1_B1_RAW
- Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Mass flow through throttle valve VIRTUS_MASS_FLOW_THROUGH
- Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2018 to 2026.
Max permissible engine torque VIRTUS_MAX_PERMISSIBLE_ENG
- Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Maximum ECU temperature VIRTUS_MAX_ECU_T
- Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Maximum filling correction factor from knock control VIRTUS_MAX_FILLING_CORR
- Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96
- Unit
- Number
In testing for 2018 to 2026.
Maximum oil level for the service interval VIRTUS_MAX_OIL_LEVEL
- Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Mean engine air mass VIRTUS_MEAN_ENG_AIR_MASS
- Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mean engine air mass VIRTUS_PQ35_MEAN_AIR_MASS
- Service 22
DID 1314 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2018 to 2026.
Mean injection quantity VIRTUS_MEAN_INJ_QTY
- Service 22
DID 2097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mean injection quantity VIRTUS_MEAN_INJ_QUANTITY
- Service 22
DID 1139 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Mileage with ECU installed VIRTUS_MILEAGE_ECU
- Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2018 to 2026.
Minimum oil level for the service interval VIRTUS_MIN_OIL_LEVEL
- Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Misfires / 1000 revolutions, cylinder 1 VIRTUS_MISFIRES_1000REV_C1
- Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires / 1000 revolutions, cylinder 2 VIRTUS_MISFIRES_1000REV_C2
- Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires / 1000 revolutions, cylinder 3 VIRTUS_MISFIRES_1000REV_C3
- Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires / 1000 revolutions, cylinder 4 VIRTUS_MISFIRES_1000REV_C4
- Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires counter:, cylinder 2 VIRTUS_MIS_CNT_2
- Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires counter:, cylinder 3 VIRTUS_MIS_CNT_3
- Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires counter:, cylinder 5 VIRTUS_MIS_CNT_5
- Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions 4 VIRTUS_MIS_PER_1000_REVOLUTIONS_4_7E0
- Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection VIRTUS_MIS_PER_1000_1
- Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 2 VIRTUS_MIS_PER_1000_2_7E0
- Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection VIRTUS_MIS_PER_1000_2
- Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 3 VIRTUS_MIS_PER_1000_3_7E0
- Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection VIRTUS_MIS_PER_1000_3
- Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection VIRTUS_MIS_PER_1000_4
- Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires total VIRTUS_MIS_TOT
- Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires total VIRTUS_MISFIRES_TOTAL
- Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 1 VIRTUS_MIS_1
- Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 1 VIRTUS_MISFIRES_C1
- Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 1,, variant 2 VIRTUS_MIS_VAR_2_1
- Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 2 VIRTUS_MIS_2
- Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 2,, variant 2 VIRTUS_MIS_VAR_2
- Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 3 VIRTUS_MIS_3
- Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 3 VIRTUS_MISFIRES_C3
- Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 3,, variant 2 VIRTUS_MIS_VAR_2_3
- Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 4 VIRTUS_MIS_4
- Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 4,, variant 2 VIRTUS_MIS_VAR_2_4
- Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mixture adaptation factor at partial load VIRTUS_MIXTURE_ADPT_FACTOR
- Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
N_32 VIRTUS_N_32
- Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2018 to 2026.
NL_PRE, 0 VIRTUS_NL_PRE_0
- Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 1 VIRTUS_NL_PRE_1
- Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 2 VIRTUS_NL_PRE_2
- Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 3 VIRTUS_NL_PRE_3
- Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
Number of automatic engine starts VIRTUS_NUM_AUTOMATIC_ENG
- Service 22
DID 2999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Number of engine starts, manual VIRTUS_NUM_ENG_STARTS
- Service 22
DID 2998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Number of injections VIRTUS_NUM_INJECTIONS
- Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded VIRTUS_NUM_TIMES_PERMITTED_T
- Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Number of warnings due to increased centrifugal oil temperature VIRTUS_NUM_WARN_HI_CENTRIF_T
- Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
NV energy requirement VIRTUS_NV_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2018 to 2026.
Oil ash limit VIRTUS_OIL_ASH_LIM
- Service 22
DID 1793 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Oil ash residue VIRTUS_OIL_ASH_RESIDUE
- Service 22
DID 208A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1310
- Unit
- Raw value
In testing for 2018 to 2026.
Oil ash residue VIRTUS_OIL_ASH_RESIDUE_7E0
- Service 22
DID 406C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Oil ash residue VIRTUS_PQ35_OIL_ASH_RESIDUE
- Service 22
DID 178C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Oil dynamic average measurement VIRTUS_PQ35_OIL_DYN_AVG
- Service 22
DID 123F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil fill level VIRTUS_PQ35_OIL_FILL_LEVEL
- Service 22
DID 2006 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil last dynamic measurement VIRTUS_PQ35_OIL_DYN_LAST
- Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil level VIRTUS_OIL_LEVELConfirmed
- Service 22
DID 11BA - Module
7E0 - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
0x0000 = 0 → = 0 cm
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Oil level method 1 VIRTUS_OIL_LEVEL_METHOD_1
- Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2018 to 2026.
Oil level method 2 VIRTUS_OIL_LEVEL_METHOD_2
- Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2018 to 2026.
Oil level method 3 VIRTUS_OIL_LEVEL_METHOD_3
- Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2018 to 2026.
Oil level test method 1 VIRTUS_OIL_LEVEL_TEST_1
- Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level test method 2 VIRTUS_OIL_LEVEL_TEST_2
- Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level test method 3 VIRTUS_OIL_LEVEL_TEST_3
- Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level, average dynamic value VIRTUS_OIL_LEVEL_AVG
- Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil level, static measured VIRTUS_OIL_LEVEL_STATIC
- Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil level, static measurement VIRTUS_OIL_LEVEL_STATIC_7E0
- Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil p VIRTUS_OIL_P
- Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil pressure actual VIRTUS_MQB_TCM_EOP_ACTUAL
- Service 22
DID 381D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2018 to 2026.
Oil pressure actual current VIRTUS_MQB_TCM_EOP_ACTUAL_I
- Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2018 to 2026.
Oil pressure control valve activation pulse duty factor VIRTUS_OIL_P_CTRL_VLV
- Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Oil pressure control valve, activation pulse duty factor VIRTUS_OIL_P_CTRL_VLV_ACTIVATION
- Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Oil pressure sensor raw value VIRTUS_OIL_P_SENS_RAW
- Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status VIRTUS_OIL_P_SENS_PISTON
- Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure sensor, raw value VIRTUS_OIL_P_SENS_RAW_7E0
- Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure switch activation, high pressure VIRTUS_OIL_P_SWITCH_P
- Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure switch for high pressure, closed VIRTUS_OIL_P_SWITCH_HIGH_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Oil pressure switch for low pressure, closed VIRTUS_OIL_P_SWITCH_LOW_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Oil pressure switch for piston-cooling jets, closed VIRTUS_OIL_P_SWITCH_PISTON
- Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure switch valve activation VIRTUS_OIL_P_SWITCH_VLV
- Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure target VIRTUS_OIL_P_TGT
- Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil pressure target VIRTUS_OIL_P_TGT_7E0
- Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil pressure valve for piston cooling nozzles, control switch button ratio VIRTUS_OIL_P_VLV_PISTON
- Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Oil pressure valve switch, control VIRTUS_OIL_P_VLV_SWITCH
- Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0
- Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0_2
- Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0_2_7E0
- Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil temp 2 VIRTUS_PQ35_ENGINE_OIL_T_2
- Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Oil temperature VIRTUS_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Oil temperature variant VIRTUS_PQ35_OIL_T_2Confirmed
- Service 22
DID 11BE - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
0xFFFA = 65530 → = 6,279.9 °C
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Oil warning threshold VIRTUS_OIL_WARN_THR
- Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 2018 to 2026.
Open cam shaft angle at quantity control valve VIRTUS_OPEN_CAM_SHFT_ANG
- Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Outside temperature, from cabin sensor VIRTUS_AAT_CABINConfirmed
- Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x95 = 149 → = 24.5 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Overall energy balance VIRTUS_OVERALL_ENERGY
- Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Oxygen control, adaptation value at part. load VIRTUS_OXYGEN_CTRL_ADPT
- Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature VIRTUS_OXYGEN_SNS_1_BANK_1_CERAMIC_T_7E0
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2018 to 2026.
Oxygen sensor 1 bank 1 lambda value VIRTUS_PQ35_O2_SEN_1_LAMBDA
- Service 22
DID 113D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 2018 to 2026.
Particle filter, field regeneration request status VIRTUS_PARTICLE_FLT_FIELD
- Service 22
DID 115B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Particle sensor, time in op.mode measurement VIRTUS_PARTICLE_SENS_TIME
- Service 22
DID 46D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2018 to 2026.
Pilot injection 1 duration VIRTUS_PQ35_PRE_INJ_1_DURATION
- Service 22
DID 14D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Pilot injection 1 start position VIRTUS_PQ35_PRE_INJ_1_START
- Service 22
DID 14C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Pilot injection 1, activation start VIRTUS_PRE_INJ_1_ACTIVATION
- Service 22
DID 12C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2018 to 2026.
Pilot injection 2 duration VIRTUS_PQ35_PRE_INJ_2_DURATION
- Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Pilot injection 2 start VIRTUS_PQ35_PRE_INJ_2_START
- Service 22
DID 14C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Pilot injection 2, activation start VIRTUS_PRE_INJ_2_ACTIVATION
- Service 22
DID 12C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2018 to 2026.
Pilot injection 3 start VIRTUS_PRE_INJ_3_START
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2018 to 2026.
Pilot injection 3, activation duration VIRTUS_PRE_INJ_3_ACTIVATION
- Service 22
DID 121A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2018 to 2026.
Pilot injection 3, activation start VIRTUS_PRE_INJ_3_ACTIVATION_START
- Service 22
DID 121D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 2018 to 2026.
Piston cooling nozzles, control VIRTUS_PISTON_COOLING
- Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Piston-cooling jets, activation VIRTUS_PISTON_COOLING_JETS
- Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Port injection injections counter VIRTUS_PORT_INJ_INJECTIONS
- Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2018 to 2026.
Post injection 1 VIRTUS_POST_INJ_1
- Service 22
DID 081A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Post injection 1 VIRTUS_POST_INJ_1_7E0
- Service 22
DID 205D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2018 to 2026.
Post injection 1: quantity specified value VIRTUS_PQ35_POST_INJ_1_QTY_SPEC
- Service 22
DID 163C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Post injection 2 VIRTUS_POST_INJ_2
- Service 22
DID 080C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Post injection 2 VIRTUS_POST_INJ_2_7E0
- Service 22
DID 205F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2018 to 2026.
Post injection 2: quantity specified value VIRTUS_PQ35_POST_INJ_2_QTY_SPEC
- Service 22
DID 163B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Post injection 3 VIRTUS_POST_INJ_3
- Service 22
DID 081B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Post injection 3 VIRTUS_POST_INJ_3_7E0
- Service 22
DID 20C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2018 to 2026.
Post injection 3: quantity specified value VIRTUS_PQ35_POST_INJ_3_QTY_SPEC
- Service 22
DID 167D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Post-injection 1 duration VIRTUS_PQ35_POST_INJ_1_DURATION
- Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Post-injection 1 start position VIRTUS_PQ35_POST_INJ_1_START
- Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Post-injection 2 duration VIRTUS_PQ35_POST_INJ_2_DURATION
- Service 22
DID 14CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Post-injection 2 start position VIRTUS_PQ35_POST_INJ_2_START
- Service 22
DID 11F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Post-injection 2, activation duration VIRTUS_POST_INJ_2_7E0_7E0
- Service 22
DID 121B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2018 to 2026.
Post-injection 3 activation duration VIRTUS_PQ35_POST_INJ_3_ACTIVATION_DURATION
- Service 22
DID 14CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2018 to 2026.
Post-injection 3 start position VIRTUS_PQ35_POST_INJ_3_START
- Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Pressure before throttle valve - actual value VIRTUS_P_BEFORE_THROTTLE_ACT
- Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Pressure before throttle valve - sensor measured VIRTUS_P_BEFORE_THROTTLE
- Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2018 to 2026.
Pressure sensor 1 temperature VIRTUS_MQB_DL382_P_SENSOR_1_T
- Service 22
DID 132A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Pressure sensor 2 temperature VIRTUS_MQB_DL382_P_SENSOR_2_T
- Service 22
DID 132B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Pressure supply actual pressure VIRTUS_MQB_DQ200_P_SUPPLY_ACTUAL_P
- Service 22
DID 1191 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Pressure supply actual pressure analog digital value VIRTUS_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE
- Service 22
DID 102D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 VIRTUS_PSN_EDGE_REL_AD_CAM_1
- Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 VIRTUS_PSN_EDGE_REL_AD_CAM_2
- Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 VIRTUS_PSN_EDGE_REL_AD_CAM_SAVE_1
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
Radiator fan 1, commanded duty VIRTUS_RADIATOR_FAN_1_CMD
- Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Radiator fan 2, commanded duty VIRTUS_RADIATOR_FAN_2_CMD
- Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2018 to 2026.
Radiator fan actual duty VIRTUS_CLIMATE_RAD_FAN_ACT_DUTYConfirmed
- Service 22
DID 2606 - Module
746 → 7B0 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x52 = 82 → = 32.8 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Radiator fan commanded duty VIRTUS_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x49 = 73 → = 29.2 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Radiator outlet coolant temperature commanded VIRTUS_PQ35_RAD_COOL_T_CMD
- Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Radiator output coolant temp: actual VIRTUS_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL
- Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Rated drive torque VIRTUS_RATED_DRIVE_TQ
- Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Reached maximum temperature VIRTUS_PQ35_REACHED_MAXIMUM_T
- Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Reducing agent tank volume, act. value filtered VIRTUS_REDUCING_AGENT_TANK_ACT
- Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 L
- Unit
- L
In testing for 2018 to 2026.
Refrigerant pressure VIRTUS_CLIMATE_REFRIG_PConfirmed
- Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 bar
- Unit
- bar
0x2A = 42 → = 8.4 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Regeneration duration VIRTUS_REGEN_DUR
- Service 22
DID 39F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1092.25 min
- Unit
- min
In testing for 2018 to 2026.
Regulation factor total VIRTUS_PQ35_REG_FACTOR
- Service 22
DID 10E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 3.276 %
- Unit
- %
In testing for 2018 to 2026.
Relative load value VIRTUS_REL_LOAD
- Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1536
- Unit
- Number
In testing for 2018 to 2026.
Relay for reserve coolant pump status VIRTUS_RELAY_RESERVE_CLT
- Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Requested torque, amount for auxiliary units VIRTUS_REQ_TQ_AMOUNT
- Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Reserve torque VIRTUS_RESERVE_TQ
- Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Result of crankcase ventilation test, fail VIRTUS_RESULT_CRANKCASE_VENTILATION_TEST
- Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Result of crankcase ventilation test, successful VIRTUS_RESULT_CRANKCASE
- Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Route data, active VIRTUS_ROUTE_DATA_ACTIVE
- Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Secondary air injection sensor 1 VIRTUS_SECONDARY_AIR_INJ_1
- Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
SEG_AD_MMV_ER_H, 0 VIRTUS_SEG_AD_MMV_ER_H_0
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_H, 3 VIRTUS_SEG_AD_MMV_ER_H_3
- Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 0 VIRTUS_SEG_AD_MMV_ER_L_0
- Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 2 VIRTUS_SEG_AD_MMV_ER_L_2
- Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 3 VIRTUS_SEG_AD_MMV_ER_L_3
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 0 VIRTUS_SEG_AD_MMV_ER_MID_0
- Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 1 VIRTUS_SEG_AD_MMV_ER_MID_1
- Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 2 VIRTUS_SEG_AD_MMV_ER_MID_2
- Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER, 2 VIRTUS_SEG_AD_MMV_ER_2
- Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER, 3 VIRTUS_SEG_AD_MMV_ER_3
- Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
Sensor for particle filter differential pressure, raw value VIRTUS_SENS_PARTICLE_FLT_P
- Service 22
DID 39E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Service limit VIRTUS_SERVICE_LIM
- Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Service limit VIRTUS_SERVICE_LIM_7E0
- Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Service limit value VIRTUS_PQ35_SRV_LIM
- Service 22
DID 12CB - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Smoke limit VIRTUS_PQ35_LIM_SMOKE
- Service 22
DID 1301 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Spark efficiency deviation at idle, maximum VIRTUS_SPARK_EFFICIENCY_DEV_MAX
- Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Spark efficiency deviation at part load VIRTUS_SPARK_EFFICIENCY_DEV
- Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Spark efficiency deviation at part load, maximum VIRTUS_SPARK_EFFICIENCY_DEV_PART_MAX
- Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Stop signal switch VIRTUS_MQB_TCM_STOP_SIGNAL_SWITCH
- Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Sum of misfires counter VIRTUS_SUM_MIS_CNT
- Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Tank fill level diagnostic reference value VIRTUS_TANK_FILL_LEVEL
- Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2018 to 2026.
TCO_1_ST VIRTUS_TCO_1_ST
- Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
TCO_1_SYS VIRTUS_TCO_1_SYS
- Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Temperature after evaporator VIRTUS_CLIMATE_T_AFTER_EVAPConfirmed
- Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -42.624 to 42.291 °C
- Unit
- °C
0x01 = 1 → = 0.333 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Temperature at air conditioner heat exchanger output VIRTUS_T_AC_HEAT_EXCHANGER
- Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
Temperature sensor for engine temperature management VIRTUS_T_SENS_ENG_T
- Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Temperature sensor for engine temperature management, target value VIRTUS_T_SENS_ENG_T_TGT
- Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Test of catalytic converter status, canceled VIRTUS_TEST_CATALYTIC_CONV_STAT
- Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Test of catalytic converter, measured value VIRTUS_TEST_CATALYTIC_CONV
- Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Number
In testing for 2018 to 2026.
Thermostat, actual VIRTUS_THERMOSTAT_ACT
- Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Thermostat, commanded VIRTUS_THERMOSTAT_CMD
- Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Throttle regulator nominal value VIRTUS_THROTTLE_REGULATOR
- Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Throttle valve adapter position VIRTUS_PQ35_THROT_VALVE_ADAPT
- Service 22
DID 12FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
TI_1_MPI, 0 VIRTUS_TI_1_MPI_0
- Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 1 VIRTUS_TI_1_MPI_1
- Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 2 VIRTUS_TI_1_MPI_2
- Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 3 VIRTUS_TI_1_MPI_3
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 1 VIRTUS_TI_MES4_PLS_1_1
- Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 2 VIRTUS_TI_MES4_PLS_1_2
- Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 3 VIRTUS_TI_MES4_PLS_1_3
- Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 0 VIRTUS_TI_MES4_PLS_2_0
- Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 1 VIRTUS_TI_MES4_PLS_2_1
- Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 2 VIRTUS_TI_MES4_PLS_2_2
- Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 3 VIRTUS_TI_MES4_PLS_2_3
- Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 0 VIRTUS_TI_MES4_PLS_3_0
- Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 1 VIRTUS_TI_MES4_PLS_3_1
- Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 2 VIRTUS_TI_MES4_PLS_3_2
- Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 3 VIRTUS_TI_MES4_PLS_3_3
- Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
Time in after-run VIRTUS_TIME_AFTERRUN
- Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2018 to 2026.
Time since last regeneration VIRTUS_TIME_SINCE_REGEN
- Service 22
DID 2089 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2018 to 2026.
Time since reset VIRTUS_TIME_SINCE_RESET
- Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2018 to 2026.
Timing angle retardation cylinder 1 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_1
- Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
Timing angle retardation cylinder 2 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_2
- Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
Timing angle retardation cylinder 3 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_3
- Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
Timing angle retardation cylinder 4 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_4
- Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after chain replacement, exhaust bank 1 VIRTUS_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after chain replacement, intake bank 1 VIRTUS_TIM_DEV_AFTER_CHAIN_1
- Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after other repairs, intake bank 1 VIRTUS_TIM_DEV_AFTER_OTHER_1
- Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after other repairs, intake bank 1 VIRTUS_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation current value exhaust bank 1 VIRTUS_TIM_DEV_CURRENT_EXH_1
- Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation current value intake bank 1 VIRTUS_TIM_DEV_CURRENT_INT_1
- Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Torque converter: torque loss VIRTUS_TORQUE_CONVERTER_TORQUE_LOSS_7E1
- Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque factor VIRTUS_TQ_FACTOR
- Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Torque increase request from ESP VIRTUS_TQ_INCREASE_REQ_ESP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limit VIRTUS_PQ35_LIM_TRQ
- Service 22
DID 106B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation VIRTUS_TORQUE_LIMITATION_7E1
- Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation VIRTUS_TQ_LIM
- Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation VIRTUS_TQ_LIM_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation, clutch protection VIRTUS_TQ_LIM_CLU
- Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation VIRTUS_TQ_LOSS_ADPT
- Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation at idle VIRTUS_TQ_LOSS_ADPT_IDLE
- Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation, A/C compressor VIRTUS_TQ_LOSS_ADPT_AC_COMP_7E0
- Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque reduction due to exhaust temperature VIRTUS_PQ35_TRQ_RED_EXH_T
- Service 22
DID 10E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3.2768 to 3.2767
- Unit
- Number
In testing for 2018 to 2026.
Torque reduction request from ESP VIRTUS_TQ_REDUCTION_REQ_ESP
- Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque request, sum of auxiliary aggregate VIRTUS_TQ_REQ_SUM_AUXILIARY
- Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque transmitting function, ratio VIRTUS_TQ_TRANSMITTING
- Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2018 to 2026.
Total mass of gasoline and ethyl alcohol in oil VIRTUS_TOT_MASS_GASOLINE
- Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1398
- Unit
- Raw value
In testing for 2018 to 2026.
Transmission drag torque VIRTUS_TCM_DRAG_TQ
- Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Transmission fluid temperature, calculated VIRTUS_ATF_T_CALCULATED_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018 to 2026.
Transmission fluid temperature, dual-clutch VIRTUS_ATF_T_DUAL_CLU
- Service 22
DID 2104 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Transmission fluid temperature, modeled maximum reached VIRTUS_ATF_T_MODELED_MAX_REACHED_7E1
- Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2018 to 2026.
Transmission torque losses VIRTUS_TCM_TQ_LOSSES
- Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Turbine actuator 1 bank 1 activation VIRTUS_PQ35_TURB_ACT_1_B1
- Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Turbine actuator 1 bank 1: activation VIRTUS_ACT
- Service 22
DID 112C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Upper adapted coupling point K1 from macro slip path adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Upper adapted coupling point K2 from macro slip path adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Valve lift system, result of last switch, intake VIRTUS_VLV_LIFT_SYSTEM
- Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve lift system, valve lift, exhaust VIRTUS_VLV_LIFT_SYSTEM_VLV_LIFT
- Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve lift system, valve lift, intake VIRTUS_VLV_LIFT_SYSTEM_VLV
- Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve timing, the difference between the, actual and the set angle VIRTUS_VLV_TIM_DIFF_ACT_SET
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °
- Unit
- °
In testing for 2018 to 2026.
Variable valve timing, intake, bank 1, switch on VIRTUS_VARIABLE_VLV_TIM_INT_1
- Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Wear index VIRTUS_PQ35_WEAR_IDX
- Service 22
DID 10E2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 m
- Unit
- m
In testing for 2018 to 2026.
Wear index %, 0=new engine VIRTUS_WEAR_INDEX_0_NEW_ENG
- Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
DPF
Regeneration duration VIRTUS_PQ35_REGEN_DUR
- Service 22
DID 1347 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 min
- Unit
- min
In testing for 2018 to 2026.
Service regeneration status VIRTUS_PQ35_SRV_REGEN_STAT
- Service 22
DID 115C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
EGR
Exhaust gas recirculation 2: filter press loss, modeled VIRTUS_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED
- Service 22
DID 2AE1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2018 to 2026.
Exhaust gas recirculation 2: filter press loss, simulated VIRTUS_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED
- Service 22
DID 2AE2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2018 to 2026.
High pressure exhaust gas recirculation closing, variant 1 VIRTUS_PQ35_HIGH_P_EGR_CLOSING_VAR_1
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
High pressure exhaust gas recirculation closing, variant 2 VIRTUS_PQ35_HIGH_P_EGR_CLOSING_VAR_2
- Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fluids
Oil level, critical VIRTUS_OIL_CRIT
- Service 22
DID 11BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Oil level, maximum VIRTUS_OIL_MAX
- Service 22
DID 11C4 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262 cm
- Unit
- cm
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Oil level, minimum VIRTUS_OIL_MIN
- Service 22
DID 11C5 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262 cm
- Unit
- cm
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel
Activation of fuel pump electronics VIRTUS_ACTIVATION_FUEL_PMP
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Counter of fuel entry in oil VIRTUS_CNT_FUEL_ENTRY_OIL
- Service 22
DID 399F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Error counter bad fuel VIRTUS_ERROR_CNT_BAD_FUEL
- Service 22
DID 44BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2018 to 2026.
Fuel consumption - actual drive cycle VIRTUS_FUEL_CONS_ACT_DRIVE
- Service 22
DID 1519 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel consumption per driving cycle VIRTUS_FUEL_CONS_PER
- Service 22
DID 51D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel filter: water level sensor 1 VIRTUS_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1
- Service 22
DID 197C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Fuel flow VIRTUS_FUEL_FLOW
- Service 22
DID 10A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 L
- Unit
- L
In testing for 2018 to 2026.
Fuel flow rate VIRTUS_PQ35_FUEL_FLOW
- Service 22
DID 111A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 L
- Unit
- L
In testing for 2018 to 2026.
Fuel high pressure, actual value VIRTUS_FUEL_HIGH_P_ACT
- Service 22
DID 2027 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel high pressure, control deviation VIRTUS_FUEL_HIGH_P_CTRL_DEV
- Service 22
DID 20BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel high pressure, specified value VIRTUS_FUEL_HIGH_P_SPEC
- Service 22
DID 293B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel injector time deviation, cylinder 1 VIRTUS_FUEL_INJ_TIME_DEV_1
- Service 22
DID 2000 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel injector time deviation, cylinder 2 VIRTUS_FUEL_INJ_TIME_DEV_2
- Service 22
DID 207B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel injector time deviation, cylinder 2 VIRTUS_FUEL_INJ_TIME_DEV_CYL_2
- Service 22
DID 21C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel injector time deviation, cylinder 3 VIRTUS_FUEL_INJ_TIME_DEV_3
- Service 22
DID 2100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel injector time deviation, cylinder 4 VIRTUS_FUEL_INJ_TIME_DEV_4
- Service 22
DID 2101 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel level VIRTUS_FLI_7E0
- Service 22
DID 1008 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2018 to 2026.
Fuel level VIRTUS_PQ35_FUEL_LEVEL_7E0_2206
- Service 22
DID 2206 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
In testing for 2018 to 2026.
Fuel level input % VIRTUS_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel level input, v1 VIRTUS_FUEL_LEVEL_INPUT_V1
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 14B4 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel level input, variant 2 VIRTUS_FLI_INPUT_VAR_2
- Service 22
DID 24FC - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2018 to 2026.
Fuel level variant VIRTUS_PQ35_FUEL_LVL_2
- Service 22
DID 100C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel low pressure, actual value VIRTUS_FUEL_LOW_P_ACT
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel low pressure, specified value VIRTUS_FUEL_LOW_P_SPEC
- Service 22
DID 2932 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel mass request, integral controller VIRTUS_FUEL_MASS_REQ_I_CTL
- Service 22
DID 130D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel mass request, proportional controller VIRTUS_FUEL_MASS_REQ_P_CTL
- Service 22
DID 1312 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2018 to 2026.
Fuel metering valve VIRTUS_FUEL_METERING_VLV
- Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel mix correction coefficient VIRTUS_FUEL_MIX_CORR
- Service 22
DID 1710 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to -73.1003
- Unit
- Number
In testing for 2018 to 2026.
Fuel part from EVAP system VIRTUS_FUEL_PART_EVAP
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -0.9996 to 0.9918
- Unit
- Number
In testing for 2018 to 2026.
Fuel pressure regulator position VIRTUS_PQ35_FUEL_P_REG
- Service 22
DID 11BF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel pressure regulator valve: specified value rail pressure VIRTUS_SPEC_VALUE_RAIL_P
- Service 22
DID 121E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Fuel pressure, low actual VIRTUS_FUEL_P_LOW_ACT
- Service 22
DID 1AB8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Fuel pump adaptation VIRTUS_FUEL_PMP_ADPT
- Service 22
DID 11C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Fuel pump specified value VIRTUS_FUEL_PMP_SPEC
- Service 22
DID 1109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel pump, commanded duty VIRTUS_FUEL_PMP_CMD_DUTY
- Service 22
DID 11A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.99 %
- Unit
- %
In testing for 2018 to 2026.
Fuel rate VIRTUS_FUEL_RATEConfirmed
- Service 22
DID 113F - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L/h
- Unit
- L/h
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Fuel rate difference, injector/sensor VIRTUS_FUEL_RATE_DIFF_INJ
- Service 22
DID 180A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127.9983 to 127.9944 L
- Unit
- L
In testing for 2018 to 2026.
Fuel rate, variant 2 VIRTUS_FUEL_RATE_VAR_2
- Service 22
DID 204C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel temperature VIRTUS_FUEL_T
- Service 22
DID 128A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Fuel temperature VIRTUS_FUEL_T_7E0
- Service 22
DID 203E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Fuel temperature VIRTUS_FUEL_T_7E0_2
- Service 22
DID 111C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2018 to 2026.
High fuel pressure control deviation VIRTUS_HIGH_FUEL_P_CONTROL_DEVIATION
- Service 22
DID 121F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
High fuel pressure, actual VIRTUS_HIGH_FUEL_P_ACT
- Service 22
DID 159F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, actual value VIRTUS_HIGH_FUEL_P_ACT_7E0
- Service 22
DID 4460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, commanded VIRTUS_HIGH_FUEL_P_CMD
- Service 22
DID 11D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, regulation error VIRTUS_HIGH_FUEL_P
- Service 22
DID 11D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, target VIRTUS_HIGH_FUEL_P_TGT
- Service 22
DID 111B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2018 to 2026.
High pressure fuel pressure actual VIRTUS_PQ35_FUEL_P_HIGH
- Service 22
DID 1169 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2026.
High pressure fuel pressure commanded VIRTUS_PQ35_FUEL_P_HIGH_CMD
- Service 22
DID 116A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2026.
Long term fuel trim at idle VIRTUS_LONG_TERM_FUEL_TRIM_7E0
- Service 22
DID 110E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 %
- Unit
- %
In testing for 2018 to 2026.
Long term fuel trim at idle VIRTUS_LONG_TERM_FUEL_TRIM_IDLE_7E0
- Service 22
DID 4381 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2018 to 2026.
Long term fuel trim bank 1 VIRTUS_LONG_TERM_FUEL_TRIM_1
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2018 to 2026.
Long term fuel trim direct injection at load VIRTUS_LONG_TERM_FUEL_TRIM
- Service 22
DID 1779 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2018 to 2026.
Long term fuel trim port injection at load VIRTUS_LONG_TERM_FUEL_TRIM_PORT
- Service 22
DID 177B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2018 to 2026.
Low fuel pressure, actual VIRTUS_LOW_FUEL_P_ACT
- Service 22
DID 11C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Low fuel pressure, commanded VIRTUS_LOW_FUEL_P_CMD
- Service 22
DID 11CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual VIRTUS_RAT_EVAPORATED_FUEL_ACT
- Service 22
DID 1711 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.9915
- Unit
- Number
In testing for 2018 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum VIRTUS_RAT_EVAPORATED_FUEL_MAX
- Service 22
DID 1712 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.992
- Unit
- Number
In testing for 2018 to 2026.
Short term fuel trim bank 1 VIRTUS_SHORT_TERM_FUEL_TRIM_1
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2018 to 2026.
Movement
A/C compressor speed VIRTUS_CLIMATE_A_C_COMP_SPDConfirmed
- Service 22
DID 2603 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
0x14 = 20 → = 2,000 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Acceleration VIRTUS_ACCEL
- Service 22
DID 2116 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Acceleration VIRTUS_ACCEL_7E0
- Service 22
DID 10CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Acceleration VIRTUS_ACCELERATION
- Service 22
DID 1187 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Acceleration VIRTUS_ACCELERATION_29BIT_7E0
- Service 22
DID 12B0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Acceleration or deceleration mode VIRTUS_ACCEL_DECCELERATION
- Service 22
DID 2118 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Accelerator pedal limit VIRTUS_PQ35_LIM_ACCEL_PED
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Accelerator pedal position VIRTUS_ACCEL_PEDAL_POS
- Service 22
DID 3804 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator pedal position VIRTUS_ACCEL_PEDAL_POS_7E1
- Service 22
DID F449 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator pedal sensor 1 VIRTUS_PQ35_ACCEL_PED_1
- Service 22
DID 1221 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Accelerator pedal sensor 2 VIRTUS_PQ35_ACCEL_PED_2
- Service 22
DID 102E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Accelerator pedal torque limit VIRTUS_ACCEL_PEDAL_TQ_LIM
- Service 22
DID 1059 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Accelerator position 1 VIRTUS_ACCEL_POS_1
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator position 2 VIRTUS_ACCEL_POS_2
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Aux. hydraulic pump RPM VIRTUS_AUX_HYDRAULIC_PMP_RPM
- Service 22
DID 70D6 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Camshaft speed VIRTUS_CAM_SPD
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Camshaft speed VIRTUS_CAM_SPD_7E0
- Service 22
DID 1092 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Camshaft speed VIRTUS_PQ35_CAMS_SPD
- Service 22
DID 133B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -9830.4 to 9830.1 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compressor speed VIRTUS_COMP_SPD
- Service 22
DID 46E1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Crankshaft speed, RPM VIRTUS_CRANK_SPD_RPM
- Service 22
DID 206E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Engine RPM VIRTUS_RPM
- Service 22
DID 16F3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Engine RPM VIRTUS_RPM_7E0
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Engine RPM at idle required VIRTUS_ENGINE_RPM_AT_IDLE_REQUIRED_7E0
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Front left wheel speed VIRTUS_FL_VSS_V2Confirmed
- Service 22
DID 1800 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Front left wheel speed VIRTUS_TIRE_FL_SPD
- Service 22
DID 2B1B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Front right wheel speed VIRTUS_FR_VSS_V2Confirmed
- Service 22
DID 1801 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Front right wheel speed VIRTUS_TIRE_FR_SPD
- Service 22
DID 2B1C - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Front right wheel speed VIRTUS_TIRE_FR_SPD_V3Confirmed
- Service 22
DID 1001 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Idle speed specified rpm VIRTUS_IDLE_SPD_SPEC_RPM
- Service 22
DID 4056 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Injection speed injector 0 VIRTUS_INJ_SPD_INJ_0
- Service 22
DID 10A4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Injection speed injector 1 VIRTUS_INJ_SPD_INJ_1
- Service 22
DID 10A5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Injection speed injector 2 VIRTUS_INJ_SPD_INJ_2
- Service 22
DID 10A6 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Injection speed injector 3 VIRTUS_INJ_SPD_INJ_3
- Service 22
DID 10A8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Input shaft speed 1 VIRTUS_INPUT_SHFT_SPD_1
- Service 22
DID 70E0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Input shaft speed 2 VIRTUS_INPUT_SHFT_SPD_2
- Service 22
DID 70E1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Lateral acceleration VIRTUS_LATERAL_ACCEL
- Service 22
DID 1644 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Lateral acceleration, raw value VIRTUS_LATERAL_ACCEL_RAW
- Service 22
DID 15D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Longitudinal acceleration VIRTUS_LONGITUDINAL_ACCEL_7E0
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Longitudinal acceleration, raw value VIRTUS_LONGITUDINAL_ACCEL
- Service 22
DID 15CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Misfires per 1000 rpm, all cylinders VIRTUS_MIS_PER_1000_RPM_ALL
- Service 22
DID 148B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 rpm:, cylinder 3 VIRTUS_MIS_PER_1000_RPM_3
- Service 22
DID 1486 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 rpm:, cylinder 5 VIRTUS_MIS_PER_1000_RPM_5
- Service 22
DID 1489 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 1 VIRTUS_MISFIRES_1000_RPM_C1_7E0
- Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 2 VIRTUS_MISFIRES_1000_RPM_C2_7E0
- Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 3 VIRTUS_MISFIRES_1000_RPM_C3_7E0
- Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 4 VIRTUS_MISFIRES_1000_RPM_C4_7E0
- Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mixture adaptation factor at idle speed VIRTUS_MIXTURE_ADPT_FACTOR_IDLE
- Service 22
DID 3997 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Rear left wheel speed VIRTUS_RL_VSS_V2Confirmed
- Service 22
DID 1802 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Rear left wheel speed VIRTUS_TIRE_RL_SPD
- Service 22
DID 2B1D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Rear left wheel speed VIRTUS_TIRE_RL_SPD_V3Confirmed
- Service 22
DID 1004 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x0008 = 8 → = 0.8 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel speed VIRTUS_RR_VSS_V2Confirmed
- Service 22
DID 1803 - Module
713 → 77D - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel speed VIRTUS_TIRE_RR_SPD
- Service 22
DID 2B1E - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Reducing agent pump, differential speed calculated VIRTUS_REDUCING_AGENT_PMP
- Service 22
DID 18CC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Specified idle RPM VIRTUS_MQB_DQ250_SPECIFIED_IDLE_RPM
- Service 22
DID 3871 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Speed output VIRTUS_MQB_DQ250_SPD_OUTPUT
- Service 22
DID 1009 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Transmission input shaft speed VIRTUS_PQ35_TRANS_IN_SPD
- Service 22
DID 11F1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Transmission input speed VIRTUS_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A
- Service 22
DID 380A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Transmission output speed VIRTUS_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B
- Service 22
DID 380B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Vehicle speed VIRTUS_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Vehicle speed VIRTUS_VSS_7E1
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Vehicle speed ESP VIRTUS_VSS_ESP
- Service 22
DID 1005 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Vehicle speed from transmission VIRTUS_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION
- Service 22
DID 100A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Vehicle speed, HR VIRTUS_VSS_HR
- Service 22
DID 2106 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Yaw acceleration, raw value VIRTUS_YAW_ACCEL_RAW
- Service 22
DID 15D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Stats
Driving time, eco VIRTUS_DRIVE_TIME_ECO
Value may be wrong, needs more validation. Proportion of time spent driving in eco mode
- Service 22
DID 0303 - Module
7E1 → 7E9 - Every
900 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Driving time, manual VIRTUS_DRIVE_TIME_MANUAL
Value may be wrong, needs more validation. Proportion of time spent driving in manual mode
- Service 22
DID 0305 - Module
7E1 → 7E9 - Every
900 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Driving time, sport VIRTUS_DRIVE_TIME_SPORT
Value may be wrong, needs more validation. Proportion of time spent driving in sport mode
- Service 22
DID 0304 - Module
7E1 → 7E9 - Every
900 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Total drive time VIRTUS_DRIVE_TIME
- Service 22
DID 0302 - Module
7E1 → 7E9 - Every
900 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 h
- Unit
- h
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Tires
Entire energy throughput VIRTUS_ENTIRE_ENERGY
- Service 22
DID 2A18 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -838860 to 838860 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Front left flat tire indicator VIRTUS_TPMS_FR_L_FLAT_TIRE_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 296 to 303 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x0B = 11 → 11
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front left tire pressure diffusion indicator VIRTUS_TPMS_FR_L_TIRE_P_DIFF_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 264 to 271 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x09 = 9 → 9
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front left wheel speed VIRTUS_FL_WHL_SPD_713
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Front right flat tire indicator VIRTUS_TPMS_FR_R_FLAT_TIRE_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 304 to 311 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x50 = 80 → 80
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front right tire pressure diffusion indicator VIRTUS_TPMS_FR_R_TIRE_P_DIFF_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 272 to 279 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x06 = 6 → 6
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front right wheel speed VIRTUS_FR_WHL_SPD_713
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Rear left flat tire indicator VIRTUS_TPMS_RR_L_FLAT_TIRE_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 312 to 319 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x05 = 5 → 5
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rear left tire pressure diffusion indicator VIRTUS_TPMS_RR_L_TIRE_P_DIFF_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 280 to 287 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x10 = 16 → 16
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rear left wheel speed VIRTUS_RL_WHL_SPD_713
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Rear right flat tire indicator VIRTUS_TPMS_RR_R_FLAT_TIRE_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 320 to 327 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rear right tire pressure diffusion indicator VIRTUS_TPMS_RR_R_TIRE_P_DIFF_INDConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x7F = 127 → 127
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rear right wheel speed VIRTUS_RR_WHL_SPD_713
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2018 to 2026.
Steering wheel angle VIRTUS_STEER_WHEEL_ANGLE_ABS
- Service 22
DID 1804 - Module
713 → 77D - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -14336 to 14335.5625 °
- Unit
- °
In testing for 2018 to 2026.
Steering wheel temperature VIRTUS_STEER_WHL_T
- Service 22
DID 5505 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2018 to 2026.
Tire pressure monitoring available? VIRTUS_TPMS_AVAILConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Transmission
Actual position clutch 1 duty cycle factor 1 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1
- Service 22
DID 3832 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Actual position clutch 1 duty cycle factor 2 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2
- Service 22
DID 3833 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Actual position clutch 2 duty cycle factor 1 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1
- Service 22
DID 383B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Actual position clutch 2 duty cycle factor 2 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2
- Service 22
DID 383C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Actual position of gear actuator a VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A
- Service 22
DID 3852 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Actual position of gear actuator b VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B
- Service 22
DID 385A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Actual position of gear actuator c VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C
- Service 22
DID 3862 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Actual position of gear actuator d VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D
- Service 22
DID 386A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Adaptation counter PF lockup clutch VIRTUS_ADPT_CNT_PF_LOCKUP
- Service 22
DID 1103 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, clutch a VIRTUS_ADPT_CNT_CLU
- Service 22
DID 7085 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, clutch b VIRTUS_ADPT_CNT_CLU_B
- Service 22
DID 7089 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, clutch c VIRTUS_ADPT_CNT_CLU_C
- Service 22
DID 708D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, clutch d VIRTUS_ADPT_CNT_CLU_D
- Service 22
DID 7091 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, clutch e VIRTUS_ADPT_CNT_CLU_E
- Service 22
DID 7095 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, fast fill time, clutch a VIRTUS_ADPT_CNT_FAST_FILL
- Service 22
DID 7087 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, fast fill time, clutch b VIRTUS_ADPT_CNT_FAST_FILL_B
- Service 22
DID 708B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, fast fill time, clutch c VIRTUS_ADPT_CNT_FAST_FILL_C
- Service 22
DID 708F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, fast fill time, clutch d VIRTUS_ADPT_CNT_FAST_FILL_D
- Service 22
DID 7093 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, fast fill time, clutch e VIRTUS_ADPT_CNT_FAST_FILL_E
- Service 22
DID 7097 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Adaptation counter, torque converter lockup clutch VIRTUS_ADPT_CNT_TSF_LOCKUP
- Service 22
DID 1101 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Adaptation fill time, torque converter lockup clutch VIRTUS_ADPT_INFLATION_TIME
- Service 22
DID 1100 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 2018 to 2026.
Adaptation inflation current PF lockup clutch VIRTUS_ADPT_INFLATION
- Service 22
DID 1102 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mA
- Unit
- mA
In testing for 2018 to 2026.
Automatic transmission input speed VIRTUS_AT_INPUT_SPEED
- Service 22
DID 2102 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Automatic transmission output speed VIRTUS_AT_OUTPUT_SPEED
- Service 22
DID 2103 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Clutch 0 commanded pressure offset VIRTUS_MQB_DL382_CLUTCH_0_CMD_P_OFFSET
- Service 22
DID 1426 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 absolute pressure VIRTUS_MQB_DL382_CLUTCH_1_ABSOLUTE_P
- Service 22
DID 13CC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 actual pressure VIRTUS_PQ35_CLUTCH_1_ACTUAL_P
- Service 22
DID 38EB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 actual pressure raw value VIRTUS_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE
- Service 22
DID 10F9 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 0 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT
- Service 22
DID 1058 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 0 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS
- Service 22
DID 1057 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 1 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT
- Service 22
DID 105A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 1 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS
- Service 22
DID 1059 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 2 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT
- Service 22
DID 105C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 2 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS
- Service 22
DID 105B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 3 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT
- Service 22
DID 105E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristic point 3 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS
- Service 22
DID 105D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristics point 0 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS
- Service 22
DID 38AE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristics point 1 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS
- Service 22
DID 38AF - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristics point 2 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS
- Service 22
DID 7000 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 adaptation basic characteristics point 3 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS
- Service 22
DID 7001 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 adaptation clutch end position closed VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED
- Service 22
DID 38FF - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 adaptation clutch end position open VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN
- Service 22
DID 38FE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 characteristic curve shift VIRTUS_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT
- Service 22
DID 1063 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.11 to 32.11 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 1 commanded pressure VIRTUS_PQ35_CLUTCH_1_CMD_P
- Service 22
DID 38EC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 failed adaptations counter VIRTUS_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER
- Service 22
DID 10CC - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 1 friction value correction factor VIRTUS_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR
- Service 22
DID 1062 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Clutch 1 lower adaptation point VIRTUS_CLU_1_LO_ADPT_POINT
- Service 22
DID 1120 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 nominal pressure VIRTUS_CLU_1_NOMINAL_P
- Service 22
DID 125C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 pressure VIRTUS_MQB_DL382_CLUTCH_1_P
- Service 22
DID 214C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 protection function engaged quantity VIRTUS_PQ35_CLUTCH_1_PROT_ENGAGED_QTY
- Service 22
DID 1069 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2018 to 2026.
Clutch 1 successful adaptations counter VIRTUS_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10C9 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 1 upper adaptation point VIRTUS_CLU_1_HI_ADPT_POINT
- Service 22
DID 1124 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 1 valve current: actual VIRTUS_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL
- Service 22
DID 3835 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch 1 valve current: specified VIRTUS_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED
- Service 22
DID 3834 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch 2 absolute pressure VIRTUS_MQB_DL382_CLUTCH_2_ABSOLUTE_P
- Service 22
DID 13CD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 actual pressure VIRTUS_PQ35_CLUTCH_2_ACTUAL_P
- Service 22
DID 38EA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 actual pressure raw value VIRTUS_PQ35_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUE
- Service 22
DID 10FA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 actual torque VIRTUS_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE
- Service 22
DID 3839 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 0 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT
- Service 22
DID 106D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 0 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS
- Service 22
DID 106C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 1 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT
- Service 22
DID 106F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 1 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS
- Service 22
DID 106E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 2 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT
- Service 22
DID 1071 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 2 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS
- Service 22
DID 1070 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 3 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT
- Service 22
DID 1073 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristic point 3 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS
- Service 22
DID 1072 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristics point 0 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS
- Service 22
DID 38FA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristics point 1 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS
- Service 22
DID 38FB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristics point 2 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS
- Service 22
DID 38FC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation basic characteristics point 3 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS
- Service 22
DID 38FD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation clutch end position closed VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED
- Service 22
DID 38AB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation clutch end position open VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN
- Service 22
DID 38AA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 adaptation end position closed VIRTUS_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED
- Service 22
DID 1075 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 adaptation end position opened VIRTUS_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED
- Service 22
DID 1074 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 characteristic curve shift VIRTUS_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT
- Service 22
DID 1078 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.11 to 32.11 mm
- Unit
- mm
In testing for 2018 to 2026.
Clutch 2 commanded pressure VIRTUS_PQ35_CLUTCH_2_CMD_P
- Service 22
DID 38ED - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 failed adaptations counter VIRTUS_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER
- Service 22
DID 10ED - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 friction value correction factor VIRTUS_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR
- Service 22
DID 1077 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Clutch 2 lower adaptation point VIRTUS_CLU_2_LO_ADPT_POINT
- Service 22
DID 1121 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 pressure VIRTUS_MQB_DL382_CLUTCH_2_P
- Service 22
DID 214D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 protection function engaged quantity VIRTUS_PQ35_CLUTCH_2_PROT_ENGAGED_QTY
- Service 22
DID 107E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 successful adaptations counter VIRTUS_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10EA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Clutch 2 upper adaptation point VIRTUS_CLU_2_HI_ADPT_POINT
- Service 22
DID 1125 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Clutch 2 valve current: actual VIRTUS_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL
- Service 22
DID 383E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch 2 valve current: specified VIRTUS_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED
- Service 22
DID 383D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch adaptation values initial kill point 0 for K1 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1
- Service 22
DID 1156 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch adaptation values initial kill point 0 for K2 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2
- Service 22
DID 1157 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch adaptation values lower current point adaptation K1 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1
- Service 22
DID 1158 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch adaptation values lower current point adaptation K2 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2
- Service 22
DID 1159 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Clutch kiss point rapid adaptation remaining VIRTUS_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING
- Service 22
DID 1711 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2018 to 2026.
Clutch overheating, clutch VIRTUS_CLU_OVERHEATING_CLU
- Service 22
DID 17FD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Clutch temperature VIRTUS_CLU_T
- Service 22
DID 1259 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Correction values for main press adaptation: high press on clutch 1 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1
- Service 22
DID 1181 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Correction values for main press adaptation: low press on clutch 1 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1
- Service 22
DID 1180 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Correction values for main pressure adaptation high pressure on clutch 2 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2
- Service 22
DID 1183 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Correction values for main pressure adaptation low pressure on clutch 2 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2
- Service 22
DID 1182 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2018 to 2026.
Current gear VIRTUS_CURRENT_GEAR
- Service 22
DID 3EDE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2018 to 2026.
Current gear VIRTUS_GEARConfirmed
The automatic transmission gear.
- Service 22
DID 210F - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x06 = 6 → 6
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.
Current gear VIRTUS_MQB_TCM_I_GEAR_DQ200
- Service 22
DID 3816 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 254
- Unit
- Number
In testing for 2018 to 2026.
Current gear VIRTUS_PQ35_GEAR
- Service 22
DID 100D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2018 to 2026.
Current lower pressure point clutch 1 from current to pressure adaptation VIRTUS_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1130 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Current lower pressure point clutch 2 from current to pressure adaptation VIRTUS_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1132 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Current N371 pressure control valve 6 lock-up clutch VIRTUS_CURRENT_N371_P_CTRL_6
- Service 22
DID 1029 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2018 to 2026.
Current upper pressure point clutch 1 from current to pressure adaptation VIRTUS_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1131 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Current upper pressure point clutch 2 from current to pressure adaptation VIRTUS_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1133 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2018 to 2026.
Driving strategy mountain factor VIRTUS_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR
- Service 22
DID 1018 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Driving strategy sport factor VIRTUS_PQ35_DRIVING_STRATEGY_SPORT_FACTOR
- Service 22
DID 1019 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Dynamic shift program VIRTUS_DYNAMIC_SHIFT
- Service 22
DID 2115 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for oxygen shift, cylinder 1 VIRTUS_EARLY_IGN_CNT_OXYGEN_1
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for oxygen shift, cylinder 2 VIRTUS_EARLY_IGN_CNT_OXYGEN_2
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for oxygen shift, cylinder 3 VIRTUS_EARLY_IGN_CNT_OXYGEN_3
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter for oxygen shift, cylinder 4 VIRTUS_EARLY_IGN_CNT_OXYGEN_4
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engaged position side a gear selector 1-3 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 1138 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side a gear selector 2-4 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 1139 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side a gear selector 5 and neutral VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side a gear selector 6 and reverse VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side b gear selector 1-3 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1144 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side b gear selector 2-4 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1145 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side b gear selector 5 and neutral VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 1146 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engaged position side b gear selector 6 and reverse VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 1147 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Engine specified torque during transmission intervention VIRTUS_ENG_SPEC_TQ_DURING
- Service 22
DID 2110 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Fast fill time, clutch a VIRTUS_FAST_FILL_TIME_CLU
- Service 22
DID 7086 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2018 to 2026.
Fast fill time, clutch b VIRTUS_FAST_FILL_TIME_CLU_B
- Service 22
DID 708A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2018 to 2026.
Fast fill time, clutch c VIRTUS_FAST_FILL_TIME_CLU_C
- Service 22
DID 708E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2018 to 2026.
Fast fill time, clutch d VIRTUS_FAST_FILL_TIME_CLU_D
- Service 22
DID 7092 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2018 to 2026.
Fast fill time, clutch e VIRTUS_FAST_FILL_TIME_CLU_E
- Service 22
DID 7096 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2018 to 2026.
Fill pressure, clutch a VIRTUS_FILL_P_CLU
- Service 22
DID 7084 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2018 to 2026.
Fill pressure, clutch b VIRTUS_FILL_P_CLU_B
- Service 22
DID 7088 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2018 to 2026.
Fill pressure, clutch c VIRTUS_FILL_P_CLU_C
- Service 22
DID 708C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2018 to 2026.
Fill pressure, clutch d VIRTUS_FILL_P_CLU_D
- Service 22
DID 7090 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2018 to 2026.
Fill pressure, clutch e VIRTUS_FILL_P_CLU_E
- Service 22
DID 7094 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2018 to 2026.
Gear VIRTUS_GEAR_V2
- Service 22
DID 14CB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G1 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1
- Service 22
DID 1082 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G2 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2
- Service 22
DID 1090 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G3 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3
- Service 22
DID 1086 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G4 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4
- Service 22
DID 1094 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G5 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5
- Service 22
DID 109E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G6 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6
- Service 22
DID 10AC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position G7 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7
- Service 22
DID 10A2 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation engaged position GR VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR
- Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G1 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1
- Service 22
DID 1083 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G2 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2
- Service 22
DID 1091 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G3 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3
- Service 22
DID 1085 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G4 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4
- Service 22
DID 1093 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G5 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5
- Service 22
DID 109F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G6 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6
- Service 22
DID 10AD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position G7 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7
- Service 22
DID 10A1 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear actuator adaptation synchronization position reverse VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR
- Service 22
DID 10AF - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear selector a adaptation neutral position VIRTUS_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS
- Service 22
DID 1084 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear selector b adaptation neutral position VIRTUS_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS
- Service 22
DID 1092 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear selector c adaptation neutral position VIRTUS_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS
- Service 22
DID 10A0 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear selector d adaptation neutral position VIRTUS_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS
- Service 22
DID 10AE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2018 to 2026.
Gear selector synchronous position g and reverse VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R
- Service 22
DID 117F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G1 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1
- Service 22
DID 1179 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G2 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2
- Service 22
DID 117A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G3 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3
- Service 22
DID 117B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G4 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4
- Service 22
DID 117C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G5 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5
- Service 22
DID 117D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Gear selector synchronous position G6 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6
- Service 22
DID 117E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2018 to 2026.
Input shaft 1 VIRTUS_MQB_INPUT_SHAFT_1
- Service 22
DID 380C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Input shaft 2 VIRTUS_MQB_INPUT_SHAFT_2
- Service 22
DID 380D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Launch control counter, clutch 1 VIRTUS_LAUNCH_CTRL_CNT_CLU_1
- Service 22
DID 38C0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Load shift flaps, actual value VIRTUS_LOAD_SHIFT_FLAPS_ACT
- Service 22
DID 295C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Load shift flaps, specified value VIRTUS_LOAD_SHIFT_FLAPS_SPEC
- Service 22
DID 295D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Lower adapted coupling point clutch 1 from kiss point adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT
- Service 22
DID 388D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2018 to 2026.
Lower adapted coupling point clutch 2 from kiss point adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT
- Service 22
DID 388E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2018 to 2026.
Mileage of oxidation catalytic converter VIRTUS_MILEAGE_OXIDATION
- Service 22
DID 51A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2018 to 2026.
Neutral position gear selector 1-3 VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3
- Service 22
DID 1140 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Neutral position gear selector 2-4 VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4
- Service 22
DID 1141 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Neutral position gear selector 5 and neutral VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N
- Service 22
DID 1142 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Neutral position gear selector 6 and reverse VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R
- Service 22
DID 1143 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Nominal pressure clutch 2 VIRTUS_NOMINAL_P_CLU_2
- Service 22
DID 125D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2018 to 2026.
Output shaft 1 VIRTUS_MQB_OUTPUT_SHAFT_1
- Service 22
DID 380E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Output shaft 2 VIRTUS_MQB_OUTPUT_SHAFT_2
- Service 22
DID 380F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Powertrain overall gear ratio VIRTUS_POWERTRAIN_OVERALL
- Service 22
DID 11DF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Number
In testing for 2018 to 2026.
Pressure_clutch_1 VIRTUS_P_CLU_1
- Service 22
DID 1260 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Pressure_clutch_2 VIRTUS_P_CLU_2
- Service 22
DID 1261 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2018 to 2026.
Road resistance VIRTUS_PQ35_ROAD_RESISTANCE
- Service 22
DID 1017 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -31 to 31.894 %
- Unit
- %
In testing for 2018 to 2026.
Selected gear VIRTUS_PQ35_SELECTED_GEAR
- Service 22
DID 15AA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Selected gear VIRTUS_SELECTED_GEAR_7E1
- Service 22
DID 7050 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253 °C
- Unit
- °C
In testing for 2018 to 2026.
Shift process, selected gear VIRTUS_SHIFT_PROCCESS
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Shift process, target gear VIRTUS_SHIFT_PROCCESS_TGT
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Specified torque clutch 1 VIRTUS_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1
- Service 22
DID 382E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Specified torque clutch 1 - data VIRTUS_SPEC_TQ_CLU_1_DATA
- Service 22
DID 2142 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Specified torque clutch 2 VIRTUS_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2
- Service 22
DID 3838 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638 to 1638.35 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Specified torque clutch 2 - data VIRTUS_SPEC_TQ_CLU_2_DATA
- Service 22
DID 2143 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Stiffness point pressure clutch 1 VIRTUS_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1
- Service 22
DID 1419 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2018 to 2026.
Stiffness point pressure clutch 2 VIRTUS_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2
- Service 22
DID 141A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2018 to 2026.
Synchronous position side a gear selector 1-3 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 113C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side a gear selector 2-4 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 113D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side a gear selector 5 and neutral VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side a gear selector 6 and reverse VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side b gear selector 1-3 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1148 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side b gear selector 2-4 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1149 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side b gear selector 5 and neutral VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 114A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Synchronous position side b gear selector 6 and reverse VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 114B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2018 to 2026.
Time since shift VIRTUS_TIME_SINCE_SHIFT
- Service 22
DID 1033 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2018 to 2026.
Torque converter amplification VIRTUS_TQ_CONV
- Service 22
DID 2130 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
In testing for 2018 to 2026.
Torque converter lockup clutch status VIRTUS_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS
- Service 22
DID 7078 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Torque loss adaptation, A/C compressor + gear engaged VIRTUS_TQ_LOSS_ADPT_AC_COMP
- Service 22
DID 1222 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation, gear engaged VIRTUS_TQ_LOSS_ADPT_GEAR
- Service 22
DID 1224 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Transmission coolant valve, open VIRTUS_TRANS_CLT_VLV_OPEN
- Service 22
DID 3D74 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Transmission fluid temperature 2 VIRTUS_ATF_T_2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 38BF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Transmission gear ratio VIRTUS_TRANS_GEAR_RAT
- Service 22
DID 0327 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1.28 to 1.27
- Unit
- Number
In testing for 2018 to 2026.
Transmission part 1 pressure actual VIRTUS_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL
- Service 22
DID 3821 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2018 to 2026.
Transmission part 1 pressure commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_1_P_CMD
- Service 22
DID 3820 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2018 to 2026.
Transmission part 1 valve current actual VIRTUS_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL
- Service 22
DID 3827 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2018 to 2026.
Transmission part 1 valve current commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD
- Service 22
DID 3826 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2018 to 2026.
Transmission part 2 pressure actual VIRTUS_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL
- Service 22
DID 3824 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2018 to 2026.
Transmission part 2 pressure commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_2_P_CMD
- Service 22
DID 3823 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2018 to 2026.
Transmission part 2 valve current actual VIRTUS_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL
- Service 22
DID 382B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2018 to 2026.
Transmission part 2 valve current commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD
- Service 22
DID 382A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2018 to 2026.
Upper adapted coupling point clutch 1 from micro-slip adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT
- Service 22
DID 388F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2018 to 2026.
Upper adapted coupling point clutch 2 from micro-slip adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT
- Service 22
DID 3890 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2018 to 2026.
Working hours VIRTUS_PQ35_WORKING_HOURS
- Service 22
DID 1110 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.929
- Unit
- Raw value
In testing for 2018 to 2026.
Trips
Analysis, clutch 1 temperature time in range 1 VIRTUS_ANALYSIS_CLU_1_T_1
- Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 1 temperature time in range 2 VIRTUS_ANALYSIS_CLU_1_T_2
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 1 temperature time in range 3 VIRTUS_ANALYSIS_CLU_1_T_3
- Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 0 VIRTUS_ANALYSIS_CLU_2_T_0
- Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 1 VIRTUS_ANALYSIS_CLU_2_T_1
- Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 2 VIRTUS_ANALYSIS_CLU_2_T_2
- Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 3 VIRTUS_ANALYSIS_CLU_2_T_3
- Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Clutch 1 adaptation kiss point part 1 odometer reading VIRTUS_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING
- Service 22
DID 10CA - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2018 to 2026.
Clutch 1 temperature time in range 0 VIRTUS_CLU_1_T_TIME_RANGE_0
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Clutch 2 adaptation kiss point part 1 odometer reading VIRTUS_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING
- Service 22
DID 10EB - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2018 to 2026.
Counter steer support, odometer, last activated VIRTUS_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACTConfirmed
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 1 km
- Unit
- km
0x000000 = 0 → 0 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Distance since last regeneration VIRTUS_DIST_SINCE_REGEN
- Service 22
DID 208D - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2018 to 2026.
Drive cycles counter VIRTUS_MQB_TCM_DRIVE_CYCLES_COUNTER
- Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Driving time ecological VIRTUS_MQB_TCM_DRIVING_TIME_ECOLOGICAL
- Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Driving time manual VIRTUS_MQB_TCM_DRIVING_TIME_MANUAL
- Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Driving time sporty VIRTUS_MQB_TCM_DRIVING_TIME_SPORTY
- Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Ignition cycles VIRTUS_MQB_TCM_IGNITION_CYCLES
- Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mixture variation in adapted part load range 1 VIRTUS_MIXTURE_VARIATION_1
- Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Odometer VIRTUS_ODO_7E0Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 10E0 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4000000000 km
- Unit
- km
0x000073F0 = 29680 → 29,680 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Odometer VIRTUS_ODO_7E0_7E0
Pelican can show this parameter as the odometer.
- Service 22
DID 108C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2018 to 2026.
Odometer VIRTUS_ODO_7E1
Pelican can show this parameter as the odometer.
- Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2018 to 2026.
Odometer VIRTUS_ODO_V1Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3841 - Module
7E1 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729 km
- Unit
- km
0x60870400 = 1619461120 → = 161,946,112 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Odometer #2 VIRTUS_MQB_TCM_ODO_2Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3887 - Module
7E1 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x00000000 = 0 → = 0 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Odometer #3 VIRTUS_PQ35_ODO_3Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 101A - Module
7E1 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00559F = 21919 → 21,919 km
Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.
Odometer at oxidation catalytic converter replacement VIRTUS_ODO_OXYDATION
- Service 22
DID 4F3F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2018 to 2026.
Odometer reading at fourth-to-last warning VIRTUS_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARNConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 232 to 263 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
0x0000A822 = 43042 → 43,042 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading at last adaptation VIRTUS_TPMS_ODO_RDG_AT_LAST_ADAPTConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 8 to 39 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading at last warning VIRTUS_TPMS_ODO_RDG_AT_LAST_WARNConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 136 to 167 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading at next-to-last warning VIRTUS_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARNConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 168 to 199 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading at third-to-last warning VIRTUS_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARNConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 200 to 231 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading four adaptations ago VIRTUS_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGOConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 104 to 135 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading three adaptations ago VIRTUS_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGOConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Volkswagen Virtus.
Bits 72 to 103 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
0x0000133F = 4927 → 4,927 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer reading two adaptations ago VIRTUS_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGOConfirmed
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 40 to 71 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Odometer with ECU installed, variant 2 VIRTUS_ODO_ECU_INSTALLED_2
- Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 m
- Unit
- m
In testing for 2018 to 2026.
Odometer, alternate VIRTUS_PQ35_ODO_2
Pelican can show this parameter as the odometer.
- Service 22
DID 16A9 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2018 to 2026.
Odometer, alternative VIRTUS_ODO_2
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Odometer, high resolution VIRTUS_ODO_HDConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 1160 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Volkswagen Virtus.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
0x01C2180B = 29497355 → = 29,497.355 km
Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.
Operating time, temperature range 1 VIRTUS_OP_TIME_T_RANGE_1
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 2 VIRTUS_OP_TIME_T_RANGE_2
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 3 VIRTUS_OP_TIME_T_RANGE_3
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 4 VIRTUS_OP_TIME_T_RANGE_4
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 5 VIRTUS_OP_TIME_T_RANGE_5
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 6 VIRTUS_OP_TIME_T_RANGE_6
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Remaining distance until reducing agent deficiency VIRTUS_REMAINING_DIST_UNTIL
- Service 22
DID 29B1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 214748364 km
- Unit
- km
In testing for 2018 to 2026.
Torque converter time in temperature range 1 VIRTUS_TQ_CONV_TIME_T_RANGE_1
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 2 VIRTUS_TQ_CONV_TIME_T_RANGE_2
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 3 VIRTUS_TQ_CONV_TIME_T_RANGE_3
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 4 VIRTUS_TQ_CONV_TIME_T_RANGE_4
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 5 VIRTUS_TQ_CONV_TIME_T_RANGE_5
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 6 VIRTUS_TQ_CONV_TIME_T_RANGE_6
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 143 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 7 VIRTUS_TQ_CONV_TIME_T_RANGE_7
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 144 to 167 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
Torque converter time in temperature range 8 VIRTUS_TQ_CONV_TIME_T_RANGE_8
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 168 to 191 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2018 to 2026.
VIRTUS_PQ35_TIME_LAST
Time since last regeneration VIRTUS_PQ35_TIME_LAST_REGEN
- Service 22
DID 115E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 0.426 min
- Unit
- min
In testing for 2018 to 2026.