Cupra Born

Parameters

The Cupra Born has 281 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage BORN_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x216F = 8559 → 85591000+4 = 12.559 V

Confirmed for 2022 to 2026. In testing for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity BORN_AUX_BAT_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

0x2E = 46 → 46 Ah

Confirmed for 2022 to 2026. In testing for 2021.

12V battery aging by capacity BORN_AUX_BAT_AGE_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5F = 95 → 95 %

Confirmed for 2022 to 2026. In testing for 2021.

12V battery aging by power BORN_AUX_BAT_AGE_POWConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x60 = 96 → 96 %

Confirmed for 2022 to 2026. In testing for 2021.

12V battery current BORN_AUX_BAT_CConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

0xFFFFDBA1 = -9311 → -93111000 = -9.311 A

Confirmed for 2022 to 2026. In testing for 2021.

12V battery soc BORN_AUX_BAT_SOCConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x63 = 99 → 99 %

Confirmed for 2022 to 2026. In testing for 2021.

12V battery total charge BORN_AUX_BAT_CHRG_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x00001580 = 5504 → 550410 = 550.4 Ah

Confirmed for 2022 to 2026. In testing for 2021.

12V battery total discharge BORN_AUX_BAT_DSCH_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x000014CF = 5327 → 532710 = 532.7 Ah

Confirmed for 2022 to 2026. In testing for 2021.

12V battery voltage BORN_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x216F = 8559 → 85591000+4 = 12.559 V

Confirmed for 2022 to 2026. In testing for 2021.

AC charging BORN_AC_CHARGINGConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Average battery consumption BORN_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x18 = 24 → 24 A

Confirmed for 2022 to 2026. In testing for 2021.

Battery cell soc max, ID BORN_HVBAT_CELL_SOC_MAX_IDConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery cell soc min, ID BORN_HVBAT_CELL_SOC_MIN_IDConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery cell soc, maximum BORN_HVBAT_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery cell soc, minimum BORN_HVBAT_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery current limit, charging BORN_HVBAT_I_LIM_CHGConfirmed

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery current limit, discharging BORN_HVBAT_I_LIM_DSCHConfirmed

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery current, DC, alternate BORN_HVBAT_I_DC_2Confirmed

  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 31 of the reply, 32 bits.

Formula
val100−1500
Range
-1500 to 42948172.95 A
Unit
A

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery current, motor controller BORN_HVBAT_I_ENGConfirmed

  • Service 22DID 035E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Battery heater current BORN_HVBAT_PTC_IConfirmed

  • Service 22DID 1620
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery heater temperature, #1 BORN_HVBAT_PTC_T_1Confirmed

  • Service 22DID 1623
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery heater temperature, #2 BORN_HVBAT_PTC_T_2Confirmed

  • Service 22DID 1624
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery heater voltage BORN_HVBAT_PTC_VConfirmed

  • Service 22DID 1621
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, inlet BORN_HVBAT_T_INConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, max BORN_HVBAT_T_MAX_V2Confirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, max sensor ID BORN_HVBAT_T_MAX_IDConfirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, min BORN_HVBAT_T_MINConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, min sensor ID BORN_HVBAT_T_MIN_IDConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery temperature, outlet BORN_HVBAT_T_OUTConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery voltage, after main switch BORN_HVBAT_V_AFTERConfirmed

  • Service 22DID 1E38
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery voltage, before main switch BORN_HVBAT_V_BEFOREConfirmed

  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery voltage, charging BORN_HVBAT_V_CHGConfirmed

  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×31249978510000000000
Range
-1023.999 to 1023.967 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery voltage, sum of all cells BORN_HVBAT_V_CELLS_SUMConfirmed

  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×2441406251000000000
Range
-524288 to 524287.99 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Battery voltage, traction mode BORN_HVBAT_V_TRACConfirmed

  • Service 22DID 4675
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 V
Unit
V

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Charge voltage, max BORN_MAXIMUM_CHARGE_VConfirmed

  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Charging duration total BORN_CHRGR_DUR_TOTALConfirmed

  • Service 22DID 15EE
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

0x0000C28E = 49806 → 49,806 min

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Charging, rapid? BORN_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Control module temperature BORN_HVBAT_ECU_TConfirmed

  • Service 22DID 1622
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Current gear BORN_DRIVE_MODEConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Cycle energy transformation BORN_OBC_CYCLE_ENERGYConfirmed

  • Service 22DID 103E
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kWh
Unit
kWh

0x0000 = 0 → 0100 = 0 kWh

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

DC battery voltage BORN_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

DC-DC converter coolant temperature BORN_DCDC_T_COOLConfirmed

  • Service 22DID 43B8
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

DC-DC converter current, alternate BORN_DCDC_I_ALTConfirmed

  • Service 22DID 465B
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 A
Unit
A

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

DC-DC converter, current BORN_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2022 to 2026. In testing for 2021.

DC-DC converter, low voltage BORN_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x7E = 126 → 12610 = 12.6 V

Confirmed for 2022 to 2026. In testing for 2021.

DC-DC converter, reserved current BORN_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x01FF = 511 → 511−511 = 0 A

Confirmed for 2022 to 2026. In testing for 2021.

DC-DC voltage BORN_DC_DC_VConfirmed

  • Service 22DID 465D
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9980469 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Discharge voltage, min BORN_MINIMUM_DISCHARGE_VConfirmed

  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

ECall battery charge level BORN_ECALL_SOCConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5F = 95 → 95 %

Confirmed for 2022 to 2026. In testing for 2021.

Ecall battery charge status BORN_ECALL_BATTERY_CHARGE_STATUSConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x02 = 2 → 2

Confirmed for 2022 to 2026. In testing for 2021.

Electric motor battery energy BORN_HV_EM_HVBAT_ENERGY_INFORMATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2024 Cupra Born.

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

0x01D3 = 467 → 467×501000 = 23.35 kWh

Confirmed for 2022 to 2024. In testing for 2021. Supported for 2025 to 2026.

Estimated electric power reserve BORN_RANGE_RESERVE_ESTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00A2 = 162 → 162 km

Confirmed for 2022 to 2026. In testing for 2021.

Estimated reserve range BORN_RANGE_EST_CANConfirmed

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00A2 = 162 → 162 km

Confirmed for 2022 to 2026. In testing for 2021.

High voltage output BORN_OBC_HIGH_V_OUTPUTConfirmed

  • Service 22DID 1DA7
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0F24 = 3876 → 387610 = 387.6 V

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

HV auxiliary current total BORN_HVAUX_IConfirmed

  • Service 22DID 0360
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

HV auxiliary power BORN_HVAUX_PWRConfirmed

  • Service 22DID 0364
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kW
Unit
kW

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

HV battery after contacts voltage BORN_HVBAT_AFTER_CONTACTS_VConfirmed

  • Service 22DID 189B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage max, ID BORN_HVBAT_CELL_V_MAX_IDConfirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage min, ID BORN_HVBAT_CELL_V_MIN_IDConfirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, maximum BORN_HVBAT_CELL_V_MAX_V2Confirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, minimum BORN_HVBAT_CELL_V_MIN_V2Confirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery energy BORN_HVBAT_KWHConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638 kWh
Unit
kWh

0x0000 = 0 → 0×251000 = 0 kWh

Confirmed for 2022 to 2026. In testing for 2021.

HV battery module temperature, #1 BORN_HVBAT_MOD_T_1Confirmed

  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #2 BORN_HVBAT_MOD_T_2Confirmed

  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #3 BORN_HVBAT_MOD_T_3Confirmed

  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #4 BORN_HVBAT_MOD_T_4Confirmed

  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #17 BORN_HVBAT_MOD_T_17Confirmed

  • Service 22DID 7425
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #18 BORN_HVBAT_MOD_T_18Confirmed

  • Service 22DID 7426
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #19 BORN_HVBAT_MOD_T_19Confirmed

  • Service 22DID 7427
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #20 BORN_HVBAT_MOD_T_20Confirmed

  • Service 22DID 7428
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #21 BORN_HVBAT_MOD_T_21Confirmed

  • Service 22DID 7429
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #22 BORN_HVBAT_MOD_T_22Confirmed

  • Service 22DID 742A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #23 BORN_HVBAT_MOD_T_23Confirmed

  • Service 22DID 742B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #24 BORN_HVBAT_MOD_T_24Confirmed

  • Service 22DID 742C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery, max energy BORN_HVBAT_CAPConfirmed

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

0x04A7 = 1191 → 1191×501000 = 59.55 kWh

Confirmed for 2022 to 2026. In testing for 2021.

HV battery: circulation pump flow BORN_CIRC_PUMP_FLOWConfirmed

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2022 to 2023, 2025 to 2026.

Non-vehicle energy requirement BORN_NV_ENERGY_REQUIREMENTConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2024 Cupra Born.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

0x33 = 51 → 51×501000 = 2.55 kWh

Confirmed for 2022 to 2024. In testing for 2021. Supported for 2025 to 2026.

On-board charger, hv/dc current BORN_OBC_HVDC_CConfirmed

  • Service 22DID 103D
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Power efficiency BORN_CHRGR_EFFICIENCYConfirmed

  • Service 22DID 15D6
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
75 to 100.5 %
Unit
%

0x00 = 0 → 010+75 = 75 %

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Rail 1 energy transformation BORN_CHRGR_RAIL1_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x0051B2 = 20914 → 2091410 = 2,091.4 kWh

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Rail 2 energy transformation BORN_CHRGR_RAIL2_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 24 to 47 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x005334 = 21300 → 2130010 = 2,130 kWh

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Rail 3 energy transformation BORN_CHRGR_RAIL3_EConfirmed

  • Service 22DID 1507
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 48 to 71 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 kWh
Unit
kWh

0x005484 = 21636 → 2163610 = 2,163.6 kWh

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Start/stop battery resistance BORN_SSB_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×210
Range
0 to 51 mΩ
Unit
mΩ

0x00 = 0 → 0×210 = 0 mΩ

Confirmed for 2022 to 2026. In testing for 2021.

State of charge BORN_SOC_FC00Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 3DEF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

State of charge BORN_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Temperature sensor, socket a BORN_OBC_T_AConfirmed

  • Service 22DID 1DDA
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 8 to 23 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498.5 °C
Unit
°C

0x0362 = 866 → 86610−55 = 31.6 °C

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Temperature, 12V battery BORN_AUX_BAT_TConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2B = 43 → 43−40 = 3 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, 12V battery sensor BORN_AUX_BAT_T_SConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2E = 46 → 46−40 = 6 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, battery BORN_BATTERY_TConfirmed

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Temperature, charger coolant BORN_CHRGR_COOLANT_TConfirmed

  • Service 22DID 15E2
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Voltage proximity, socket a BORN_OBC_V_PROX_AConfirmed

  • Service 22DID 1525
  • Module744 → 7AE
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x0F2C = 3884 → 3,884 mV

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Cells

HV battery cell voltage, #1 BORN_HVBAT_CELL_V_001Confirmed

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #2 BORN_HVBAT_CELL_V_002Confirmed

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #3 BORN_HVBAT_CELL_V_003Confirmed

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #4 BORN_HVBAT_CELL_V_004Confirmed

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #5 BORN_HVBAT_CELL_V_005Confirmed

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #6 BORN_HVBAT_CELL_V_006Confirmed

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #7 BORN_HVBAT_CELL_V_007Confirmed

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #8 BORN_HVBAT_CELL_V_008Confirmed

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #9 BORN_HVBAT_CELL_V_009Confirmed

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #10 BORN_HVBAT_CELL_V_010Confirmed

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #11 BORN_HVBAT_CELL_V_011Confirmed

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #12 BORN_HVBAT_CELL_V_012Confirmed

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #13 BORN_HVBAT_CELL_V_013Confirmed

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #14 BORN_HVBAT_CELL_V_014Confirmed

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #15 BORN_HVBAT_CELL_V_015Confirmed

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #16 BORN_HVBAT_CELL_V_016Confirmed

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #17 BORN_HVBAT_CELL_V_017Confirmed

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #18 BORN_HVBAT_CELL_V_018Confirmed

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #19 BORN_HVBAT_CELL_V_019Confirmed

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #20 BORN_HVBAT_CELL_V_020Confirmed

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #21 BORN_HVBAT_CELL_V_021Confirmed

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #22 BORN_HVBAT_CELL_V_022Confirmed

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #23 BORN_HVBAT_CELL_V_023Confirmed

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #24 BORN_HVBAT_CELL_V_024Confirmed

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #25 BORN_HVBAT_CELL_V_025Confirmed

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #26 BORN_HVBAT_CELL_V_026Confirmed

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #27 BORN_HVBAT_CELL_V_027Confirmed

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #28 BORN_HVBAT_CELL_V_028Confirmed

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #29 BORN_HVBAT_CELL_V_029Confirmed

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #30 BORN_HVBAT_CELL_V_030Confirmed

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #31 BORN_HVBAT_CELL_V_031Confirmed

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #32 BORN_HVBAT_CELL_V_032Confirmed

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #33 BORN_HVBAT_CELL_V_033Confirmed

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #34 BORN_HVBAT_CELL_V_034Confirmed

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #35 BORN_HVBAT_CELL_V_035Confirmed

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #36 BORN_HVBAT_CELL_V_036Confirmed

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #37 BORN_HVBAT_CELL_V_037Confirmed

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #38 BORN_HVBAT_CELL_V_038Confirmed

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #39 BORN_HVBAT_CELL_V_039Confirmed

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #40 BORN_HVBAT_CELL_V_040Confirmed

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #41 BORN_HVBAT_CELL_V_041Confirmed

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #42 BORN_HVBAT_CELL_V_042Confirmed

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #43 BORN_HVBAT_CELL_V_043Confirmed

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #44 BORN_HVBAT_CELL_V_044Confirmed

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #45 BORN_HVBAT_CELL_V_045Confirmed

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #46 BORN_HVBAT_CELL_V_046Confirmed

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #47 BORN_HVBAT_CELL_V_047Confirmed

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #48 BORN_HVBAT_CELL_V_048Confirmed

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #49 BORN_HVBAT_CELL_V_049Confirmed

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #50 BORN_HVBAT_CELL_V_050Confirmed

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #51 BORN_HVBAT_CELL_V_051Confirmed

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #52 BORN_HVBAT_CELL_V_052Confirmed

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #53 BORN_HVBAT_CELL_V_053Confirmed

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #54 BORN_HVBAT_CELL_V_054Confirmed

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #55 BORN_HVBAT_CELL_V_055Confirmed

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #56 BORN_HVBAT_CELL_V_056Confirmed

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #57 BORN_HVBAT_CELL_V_057Confirmed

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #58 BORN_HVBAT_CELL_V_058Confirmed

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #59 BORN_HVBAT_CELL_V_059Confirmed

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #60 BORN_HVBAT_CELL_V_060Confirmed

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #61 BORN_HVBAT_CELL_V_061Confirmed

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #62 BORN_HVBAT_CELL_V_062Confirmed

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #63 BORN_HVBAT_CELL_V_063Confirmed

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #64 BORN_HVBAT_CELL_V_064Confirmed

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #65 BORN_HVBAT_CELL_V_065Confirmed

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #66 BORN_HVBAT_CELL_V_066Confirmed

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #67 BORN_HVBAT_CELL_V_067Confirmed

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #68 BORN_HVBAT_CELL_V_068Confirmed

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #69 BORN_HVBAT_CELL_V_069Confirmed

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #70 BORN_HVBAT_CELL_V_070Confirmed

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #71 BORN_HVBAT_CELL_V_071Confirmed

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #72 BORN_HVBAT_CELL_V_072Confirmed

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #73 BORN_HVBAT_CELL_V_073Confirmed

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #74 BORN_HVBAT_CELL_V_074Confirmed

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #75 BORN_HVBAT_CELL_V_075Confirmed

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #76 BORN_HVBAT_CELL_V_076Confirmed

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #77 BORN_HVBAT_CELL_V_077Confirmed

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #78 BORN_HVBAT_CELL_V_078Confirmed

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #79 BORN_HVBAT_CELL_V_079Confirmed

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #80 BORN_HVBAT_CELL_V_080Confirmed

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #81 BORN_HVBAT_CELL_V_081Confirmed

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #82 BORN_HVBAT_CELL_V_082Confirmed

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #83 BORN_HVBAT_CELL_V_083Confirmed

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #84 BORN_HVBAT_CELL_V_084Confirmed

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #85 BORN_HVBAT_CELL_V_085Confirmed

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #86 BORN_HVBAT_CELL_V_086Confirmed

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #87 BORN_HVBAT_CELL_V_087Confirmed

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #88 BORN_HVBAT_CELL_V_088Confirmed

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #89 BORN_HVBAT_CELL_V_089Confirmed

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #90 BORN_HVBAT_CELL_V_090Confirmed

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #91 BORN_HVBAT_CELL_V_091Confirmed

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #92 BORN_HVBAT_CELL_V_092Confirmed

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #93 BORN_HVBAT_CELL_V_093Confirmed

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #94 BORN_HVBAT_CELL_V_094Confirmed

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #95 BORN_HVBAT_CELL_V_095Confirmed

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #96 BORN_HVBAT_CELL_V_096Confirmed

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #97 BORN_HVBAT_CELL_V_097Confirmed

  • Service 22DID 1EA0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #98 BORN_HVBAT_CELL_V_098Confirmed

  • Service 22DID 1EA1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #99 BORN_HVBAT_CELL_V_099Confirmed

  • Service 22DID 1EA2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #100 BORN_HVBAT_CELL_V_100Confirmed

  • Service 22DID 1EA3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #101 BORN_HVBAT_CELL_V_101Confirmed

  • Service 22DID 1EA4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #102 BORN_HVBAT_CELL_V_102Confirmed

  • Service 22DID 1EA5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #103 BORN_HVBAT_CELL_V_103Confirmed

  • Service 22DID 1EA6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #104 BORN_HVBAT_CELL_V_104Confirmed

  • Service 22DID 1EA7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #105 BORN_HVBAT_CELL_V_105Confirmed

  • Service 22DID 1EA8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #106 BORN_HVBAT_CELL_V_106Confirmed

  • Service 22DID 1EA9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #107 BORN_HVBAT_CELL_V_107Confirmed

  • Service 22DID 1EAA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery cell voltage, #108 BORN_HVBAT_CELL_V_108Confirmed

  • Service 22DID 1EAB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Modules

HV battery module temperature, #5 BORN_HVBAT_MOD_T_5Confirmed

  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #6 BORN_HVBAT_MOD_T_6Confirmed

  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #7 BORN_HVBAT_MOD_T_7Confirmed

  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #8 BORN_HVBAT_MOD_T_8Confirmed

  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #9 BORN_HVBAT_MOD_T_9Confirmed

  • Service 22DID 1EB6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #10 BORN_HVBAT_MOD_T_10Confirmed

  • Service 22DID 1EB7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #11 BORN_HVBAT_MOD_T_11Confirmed

  • Service 22DID 1EB8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #12 BORN_HVBAT_MOD_T_12Confirmed

  • Service 22DID 1EB9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #13 BORN_HVBAT_MOD_T_13Confirmed

  • Service 22DID 1EBA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #14 BORN_HVBAT_MOD_T_14Confirmed

  • Service 22DID 1EBB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #15 BORN_HVBAT_MOD_T_15Confirmed

  • Service 22DID 1EBC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

HV battery module temperature, #16 BORN_HVBAT_MOD_T_16Confirmed

  • Service 22DID 1EBD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Climate

A/C compressor power, actual BORN_AC_COMPRESSOR_PWR_ACTConfirmed

  • Service 22DID 0800
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

Confirmed for 2022 to 2026. In testing for 2021.

A/C refrigerant pressure, sensor 1 BORN_AC_REFRIG_P_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8810000
Range
0 to 576.708 bar
Unit
bar

0x0274 = 628 → 628×8810000 = 5.5264 bar

Confirmed for 2022 to 2026. In testing for 2021.

A/C refrigerant temperature, sensor 1 BORN_AC_REFRIG_T_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 369.4 °C
Unit
°C

Confirmed for 2022 to 2024, 2026. In testing for 2021. Supported for 2025.

A/C refrigerant temperature, sensor 1 interior BORN_AC_REFRIG_T_SENS1_INTConfirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 369.4 °C
Unit
°C

Confirmed for 2022 to 2024, 2026. In testing for 2021. Supported for 2025.

Air pollution level BORN_AIR_POLUTIONConfirmed

0 means clean air.

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.7 to 12.7
Unit
Number

0x0E = 14 → 1410 = 1.4

Confirmed for 2022 to 2026. In testing for 2021.

CO2 content interior BORN_CO2_CONTENT_INTERIORConfirmed

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

0x03 = 3 → 3×100 = 300

Confirmed for 2022 to 2026. In testing for 2021.

Humidity, inside BORN_HVAC_INSIDE_HUMConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x62 = 98 → 982 = 49 %

Confirmed for 2022 to 2026. In testing for 2021.

Outside humidity BORN_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2021. Not supported for 2022 to 2026.

Outside temperature BORN_AAT_V2Confirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x4E = 78 → 782−50 = -11 °C

Confirmed for 2022 to 2026. In testing for 2021.

Radiator fan actual duty BORN_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 100 %
Unit
%

0x0A = 10 → 10×25 = 4 %

Confirmed for 2022 to 2026. In testing for 2021.

Recirculation flap stop, fresh air BORN_RECIRC_FLAP_STOP_FRESHConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x009E = 158 → 158

Confirmed for 2022 to 2026. In testing for 2021.

Recirculation flap stop, recirculated air BORN_RECIRC_FLAP_STOP_RECIRCConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0355 = 853 → 853

Confirmed for 2022 to 2026. In testing for 2021.

Recirculation flap, actual BORN_RECIRC_FLAP_ACT_PCTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x83 = 131 → 1312 = 65.5 %

Confirmed for 2022 to 2026. In testing for 2021.

Recirculation flap, actual steps BORN_RECIRC_FLAP_ACT_STEPSConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0268 = 616 → 616

Confirmed for 2022 to 2026. In testing for 2021.

Recirculation flap, commanded steps BORN_RECIRC_FLAP_CMD_STEPSConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0268 = 616 → 616

Confirmed for 2022 to 2026. In testing for 2021.

Refrigerant pressure BORN_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0xFF = 255 → 2555 = 51 bar

Confirmed for 2022 to 2026. In testing for 2021.

Windshield, temperature BORN_WNDSHLD_TEMPConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

0x4B = 75 → 75×0.576−38.8 = 4.4 °C

Confirmed for 2022 to 2026. In testing for 2021.

Control

Absolute pedal position, drive BORN_APP_DConfirmed

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.55 = 0 %

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Brake booster pressure BORN_BRAKE_BOOSTER_P_V2Confirmed

  • Service 22DID 2005
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Steering wheel angle BORN_STEER_ANGLE_V2Confirmed

  • Service 22DID 0346
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °
Unit
°

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Drivetrain

Motor speed BORN_MOTOR_RPMConfirmed

  • Service 22DID 3DF8
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Motor torque difference, front to rear BORN_MOTOR_TRQ_DIFFConfirmed

  • Service 22DID 0343
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Motor torque rated, front BORN_MOTOR_TRQ_RATED_FRONTConfirmed

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Motor torque rated, rear BORN_MOTOR_TRQ_RATED_REAR

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2021, 2025. Supported for 2022, 2024. Not supported for 2023, 2026.

Motor torque requested BORN_MOTOR_TRQ_REQConfirmed

  • Service 22DID 29D4
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

Confirmed for 2022. In testing for 2021. Not supported for 2023 to 2024, 2026.

Motor torque, front BORN_MOTOR_TRQ_FRONTConfirmed

  • Service 22DID 0335
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Motor torque, rear BORN_MOTOR_TRQ_REARConfirmed

  • Service 22DID 033B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Engine

A/C clutch BORN_CLIMATE_A_C_CLCHConfirmed

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

A/C compressor load BORN_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x00 = 0 → 010 = 0 N·m

Confirmed for 2022 to 2026. In testing for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2024, 2026. Supported for 2025.

Coolant circulation pump duty BORN_COOLANT_CIRC_PUMP_DUTYConfirmed

  • Service 22DID 276D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Electric motor non-vehicle power limitation BORN_HV_EM_NV_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

0x90 = 144 → 144×50 = 7,200 W

Confirmed for 2022 to 2026. In testing for 2021.

Electric motor power limitation BORN_HV_EM_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0001 = 1 → 1×50 = 50 W

Confirmed for 2022 to 2026. In testing for 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2024, 2026. Supported for 2025.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2022. Supported for 2023 to 2026.

Front left temperature flap actual BORN_FRONT_LEFT_T_FLAP_ACTConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x7E = 126 → 1262 = 63 %

Confirmed for 2022 to 2026. In testing for 2021.

Front right temperature flap actual BORN_FRONT_RIGHT_T_FLAP_ACTConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x74 = 116 → 1162 = 58 %

Confirmed for 2022 to 2026. In testing for 2021.

Leg deflector temperature BORN_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x6C = 108 → 1083 = 36 °C

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

Outside temperature, from cabin sensor BORN_AAT_CABINConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x51 = 81 → 812−50 = -9.5 °C

Confirmed for 2022 to 2026. In testing for 2021.

Radiator fan commanded duty BORN_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2022 to 2026. In testing for 2021.

Radiator fan duty BORN_RADIATOR_FAN_DUTYConfirmed

  • Service 22DID 2055
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Temperature, evaporator output BORN_HVAC_EVAP_TConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x012C = 300 → 30010 = 30 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, front left deflector BORN_FRONT_LEFT_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x80 = 128 → 128×0.333 = 42.624 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, front right deflector BORN_FRONT_RIGHT_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x73 = 115 → 115×0.333 = 38.295 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, interior BORN_HVAC_IATConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x00ED = 237 → 23710 = 23.7 °C

Confirmed for 2022 to 2026. In testing for 2021.

Temperature, rear deflector BORN_REAR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x50 = 80 → 80×0.333 = 26.64 °C

Confirmed for 2022 to 2026. In testing for 2021.

Washer nozzle heater active BORN_HTR_NOZZLEConfirmed

  • Service 22DID 1945
  • Module70E → 778
  • Every5 s
  • Testing for 2021, 2025 to 2026

Example reply from a 2024 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2024. In testing for 2021. Not supported for 2025 to 2026.

GPS

Satellites, tracked BORN_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x10 = 16 → 16

Confirmed for 2022 to 2026. In testing for 2021.

Satellites, visible BORN_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2022 to 2026. In testing for 2021.

Movement

A/C compressor, speed BORN_A_C_CMPR_SPEEDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2022 to 2026. In testing for 2021.

Acceleration BORN_ACCEL_V3Confirmed

  • Service 22DID 4539
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Motor RPM BORN_ELDRIVE_MOTOR_RPMConfirmed

  • Service 22DID F40C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2021, 2023, 2025

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Vehicle speed BORN_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2021, 2023, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022, 2024, 2026. In testing for 2021, 2025. Not supported for 2023.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022, 2024. Supported for 2023, 2025 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2024. Supported for 2022 to 2023, 2025 to 2026.

Stats

Crashes, driver side BORN_CRASH_DRVRConfirmed

  • Service 22DID 2354
  • Module715 → 77F
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2021.

Crashes, front BORN_CRASH_FRONTConfirmed

  • Service 22DID 2353
  • Module715 → 77F
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2021.

Crashes, passenger side BORN_CRASH_PASSConfirmed

  • Service 22DID 2355
  • Module715 → 77F
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2021.

Crashes, rear BORN_CRASH_REARConfirmed

  • Service 22DID 2356
  • Module715 → 77F
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2021.

Rollovers BORN_ROLLOVERConfirmed

  • Service 22DID 2357
  • Module715 → 77F
  • Every1 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2021.

Tires

Steering wheel angle BORN_STEER_WHEEL_ANGLEConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every250 ms
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−750
Range
-750 to 780 °
Unit
°

0x0D34 = 3380 → 33808−750 = -327.5 °

Confirmed for 2022 to 2026. In testing for 2021.

Trips

Average consumption, category 0 BORN_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0063 = 99 → 9910 = 9.9 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 1 BORN_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x006B = 107 → 10710 = 10.7 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 2 BORN_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0065 = 101 → 10110 = 10.1 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 3 BORN_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0092 = 146 → 14610 = 14.6 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 4 BORN_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008B = 139 → 13910 = 13.9 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 5 BORN_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0093 = 147 → 14710 = 14.7 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Average consumption, category 6 BORN_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2022 to 2026. In testing for 2021.

Odometer BORN_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2021, 2023, 2025 to 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022, 2024. In testing for 2021, 2025. Not supported for 2023, 2026.

Range remaining, displayed BORN_RANGEConfirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2021

Example reply from a 2026 Cupra Born.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x00A2 = 162 → 162 mi

Confirmed for 2022 to 2026. In testing for 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.