Cupra Formentor

Parameters

The Cupra Formentor has 385 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage FORMENTOR_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x23A8 = 9128 → 91281000+4 = 13.128 V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity FORMENTOR_AUX_BAT_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

0x3B = 59 → 59 Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery aging by capacity FORMENTOR_AUX_BAT_AGE_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery aging by power FORMENTOR_AUX_BAT_AGE_POWConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x56 = 86 → 86 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery current FORMENTOR_AUX_BAT_CConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

0x0000139D = 5021 → 50211000 = 5.021 A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery sensor temperature FORMENTOR_AUX_BAT_T_SConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x43 = 67 → 67−40 = 27 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery soc FORMENTOR_AUX_BAT_SOCConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5A = 90 → 90 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery temperature FORMENTOR_AUX_BAT_TConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery total charge FORMENTOR_AUX_BAT_CHRG_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x00000B07 = 2823 → 282310 = 282.3 Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery total discharge FORMENTOR_AUX_BAT_DSCH_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x000009DE = 2526 → 252610 = 252.6 Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery voltage FORMENTOR_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x23A8 = 9128 → 91281000+4 = 13.128 V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

AC charging FORMENTOR_AC_CHARGINGConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

All-wheel drive voltage FORMENTOR_PQ35_HAL_VConfirmed

  • Service 22DID 2BE9
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x00 = 0 → 010 = 0 V

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Aux. hydraulic pump voltage FORMENTOR_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery acid stratification FORMENTOR_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery cell soc max, ID FORMENTOR_HVBAT_CELL_SOC_MAX_IDConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc min, ID FORMENTOR_HVBAT_CELL_SOC_MIN_IDConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc, maximum FORMENTOR_HVBAT_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc, minimum FORMENTOR_HVBAT_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery condition for display FORMENTOR_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery current filtered FORMENTOR_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery current limit, charging FORMENTOR_HVBAT_I_LIM_CHGConfirmed

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery current limit, discharging FORMENTOR_HVBAT_I_LIM_DSCHConfirmed

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery current, DC, alternate FORMENTOR_HVBAT_I_DC_2Confirmed

  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val100−1500
Range
-1500 to 42948172.95 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery internal resistance FORMENTOR_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x00 = 0 → 0×20100 = 0

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

Battery internal resistance, raw FORMENTOR_BAT_INTERNAL_RES_RAWConfirmed

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021, 2023 to 2026

Example reply from a 2022 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

0x00 = 0 → 05 = 0

Confirmed for 2022. In testing for 2020 to 2021, 2023. Not supported for 2025 to 2026.

Battery temperature, max FORMENTOR_HVBAT_T_MAX_V2Confirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, max sensor ID FORMENTOR_HVBAT_T_MAX_IDConfirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, min FORMENTOR_HVBAT_T_MINConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, min sensor ID FORMENTOR_HVBAT_T_MIN_IDConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage FORMENTOR_BATTERY_V_V2Confirmed

  • Service 22DID 105A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Battery voltage, before main switch FORMENTOR_HVBAT_V_BEFOREConfirmed

  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage, charging FORMENTOR_HVBAT_V_CHGConfirmed

  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×31249978510000000000
Range
-1023.999 to 1023.967 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage, sum of all cells FORMENTOR_HVBAT_V_CELLS_SUMConfirmed

  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×2441406251000000000
Range
-524288 to 524287.99 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Charge air pressure FORMENTOR_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Charge voltage, max FORMENTOR_MAXIMUM_CHARGE_VConfirmed

  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Charging, rapid? FORMENTOR_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2022. Supported for 2021, 2023 to 2026.

Current gear FORMENTOR_DRIVE_MODEConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC battery voltage FORMENTOR_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC-DC converter current, alternate FORMENTOR_DCDC_I_ALTConfirmed

  • Service 22DID 465B
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC-DC converter, current FORMENTOR_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x0218 = 536 → 536−511 = 25 A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC converter, low voltage FORMENTOR_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x84 = 132 → 13210 = 13.2 V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC converter, reserved current FORMENTOR_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x02FE = 766 → 766−511 = 255 A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC voltage FORMENTOR_DC_DC_VConfirmed

  • Service 22DID 465D
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.9980469 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Discharge voltage, min FORMENTOR_MINIMUM_DISCHARGE_VConfirmed

  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

ECall battery charge level FORMENTOR_ECALL_SOCConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2020 to 2021, 2023

Example reply from a 2026 Cupra Formentor.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x55 = 85 → 85 %

Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.

ECall battery status FORMENTOR_ECALL_STATUSConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2020 to 2021, 2023

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x02 = 2 → NORMAL

States
Raw valueState
1CRITICAL
2NORMAL

Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.

Electric motor battery energy FORMENTOR_EM_HVBAT_E_INFO

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Bits 40 to 55 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2020 to 2021. Supported for 2022 to 2026.

Estimated reserve range FORMENTOR_RANGE_EST_CANConfirmed

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0062 = 98 → 98 km

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

High-voltage battery current, raw count FORMENTOR_HVBAT_IConfirmed

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00023609 = 144905 → 144,905

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery capacity FORMENTOR_HVBAT_CAPConfirmed

Total possible energy in the high voltage battery

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0188 = 392 → 392×50 = 19,600 W

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

HV battery cell voltage max, ID FORMENTOR_HVBAT_CELL_V_MAX_IDConfirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage min, ID FORMENTOR_HVBAT_CELL_V_MIN_IDConfirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, maximum FORMENTOR_HVBAT_CELL_V_MAX_V2Confirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, minimum FORMENTOR_HVBAT_CELL_V_MIN_V2Confirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery charge FORMENTOR_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xBE = 190 → 190×100255 = 74.509804 %

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery energy content FORMENTOR_HVBAT_E_CONTENTConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638.37 kWh
Unit
kWh

0x0240 = 576 → 576×251000 = 14.4 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

HV battery health FORMENTOR_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 6524 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery module temperature, #1 FORMENTOR_HVBAT_MOD_T_1Confirmed

  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #2 FORMENTOR_HVBAT_MOD_T_2Confirmed

  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #3 FORMENTOR_HVBAT_MOD_T_3Confirmed

  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #4 FORMENTOR_HVBAT_MOD_T_4Confirmed

  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery total ampere hours of charge FORMENTOR_HVBAT_TOT_AH_CHRGConfirmed

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818700 Ah
Unit
Ah

0x003B05DE = 3868126 → 3868126549.31642 = 7,041.708311 Ah

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total ampere hours of discharge FORMENTOR_HVBAT_TOT_AH_DCHRGConfirmed

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val549.31642
Range
-3909350 to 3909350 Ah
Unit
Ah

0xFFC64C49 = -3781559 → -3781559549.31642 = -6,884.117901 Ah

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total kilowatt hours of charge FORMENTOR_HVBAT_TOT_KWH_CHRGConfirmed

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500300 kWh
Unit
kWh

0x01509CF2 = 22060274 → 220602748583.07212 = 2,570.207228 kWh

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total kilowatt hours of discharge FORMENTOR_HVBAT_TOT_KWH_DCHRGConfirmed

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199 to 250199 kWh
Unit
kWh

0xFEC205D0 = -20838960 → -208389608583.07212 = -2,427.913888 kWh

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery voltage FORMENTOR_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

0x05BC = 1468 → 14684 = 367 V

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery: circulation pump flow FORMENTOR_CIRC_PUMP_FLOWConfirmed

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Non-vehicle energy requirement FORMENTOR_NV_ENERGY_REQUIREMENT

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val×501000
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2020 to 2021. Supported for 2022 to 2026.

State of charge FORMENTOR_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Temperature, battery FORMENTOR_BATTERY_TConfirmed

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Cells

HV battery cell voltage, #1 FORMENTOR_HVBAT_CELL_V_001Confirmed

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #2 FORMENTOR_HVBAT_CELL_V_002Confirmed

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #3 FORMENTOR_HVBAT_CELL_V_003Confirmed

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #4 FORMENTOR_HVBAT_CELL_V_004Confirmed

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #5 FORMENTOR_HVBAT_CELL_V_005Confirmed

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #6 FORMENTOR_HVBAT_CELL_V_006Confirmed

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #7 FORMENTOR_HVBAT_CELL_V_007Confirmed

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #8 FORMENTOR_HVBAT_CELL_V_008Confirmed

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #9 FORMENTOR_HVBAT_CELL_V_009Confirmed

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #10 FORMENTOR_HVBAT_CELL_V_010Confirmed

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #11 FORMENTOR_HVBAT_CELL_V_011Confirmed

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #12 FORMENTOR_HVBAT_CELL_V_012Confirmed

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #13 FORMENTOR_HVBAT_CELL_V_013Confirmed

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #14 FORMENTOR_HVBAT_CELL_V_014Confirmed

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #15 FORMENTOR_HVBAT_CELL_V_015Confirmed

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #16 FORMENTOR_HVBAT_CELL_V_016Confirmed

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #17 FORMENTOR_HVBAT_CELL_V_017Confirmed

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #18 FORMENTOR_HVBAT_CELL_V_018Confirmed

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #19 FORMENTOR_HVBAT_CELL_V_019Confirmed

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #20 FORMENTOR_HVBAT_CELL_V_020Confirmed

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #21 FORMENTOR_HVBAT_CELL_V_021Confirmed

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #22 FORMENTOR_HVBAT_CELL_V_022Confirmed

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #23 FORMENTOR_HVBAT_CELL_V_023Confirmed

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #24 FORMENTOR_HVBAT_CELL_V_024Confirmed

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #25 FORMENTOR_HVBAT_CELL_V_025Confirmed

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #26 FORMENTOR_HVBAT_CELL_V_026Confirmed

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #27 FORMENTOR_HVBAT_CELL_V_027Confirmed

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #28 FORMENTOR_HVBAT_CELL_V_028Confirmed

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #29 FORMENTOR_HVBAT_CELL_V_029Confirmed

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #30 FORMENTOR_HVBAT_CELL_V_030Confirmed

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #31 FORMENTOR_HVBAT_CELL_V_031Confirmed

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #32 FORMENTOR_HVBAT_CELL_V_032Confirmed

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #33 FORMENTOR_HVBAT_CELL_V_033Confirmed

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #34 FORMENTOR_HVBAT_CELL_V_034Confirmed

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #35 FORMENTOR_HVBAT_CELL_V_035Confirmed

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #36 FORMENTOR_HVBAT_CELL_V_036Confirmed

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #37 FORMENTOR_HVBAT_CELL_V_037Confirmed

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #38 FORMENTOR_HVBAT_CELL_V_038Confirmed

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #39 FORMENTOR_HVBAT_CELL_V_039Confirmed

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #40 FORMENTOR_HVBAT_CELL_V_040Confirmed

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #41 FORMENTOR_HVBAT_CELL_V_041Confirmed

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #42 FORMENTOR_HVBAT_CELL_V_042Confirmed

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #43 FORMENTOR_HVBAT_CELL_V_043Confirmed

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #44 FORMENTOR_HVBAT_CELL_V_044Confirmed

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #45 FORMENTOR_HVBAT_CELL_V_045Confirmed

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #46 FORMENTOR_HVBAT_CELL_V_046Confirmed

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #47 FORMENTOR_HVBAT_CELL_V_047Confirmed

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #48 FORMENTOR_HVBAT_CELL_V_048Confirmed

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #49 FORMENTOR_HVBAT_CELL_V_049Confirmed

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #50 FORMENTOR_HVBAT_CELL_V_050Confirmed

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #51 FORMENTOR_HVBAT_CELL_V_051Confirmed

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #52 FORMENTOR_HVBAT_CELL_V_052Confirmed

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #53 FORMENTOR_HVBAT_CELL_V_053Confirmed

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #54 FORMENTOR_HVBAT_CELL_V_054Confirmed

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #55 FORMENTOR_HVBAT_CELL_V_055Confirmed

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #56 FORMENTOR_HVBAT_CELL_V_056Confirmed

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #57 FORMENTOR_HVBAT_CELL_V_057Confirmed

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #58 FORMENTOR_HVBAT_CELL_V_058Confirmed

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #59 FORMENTOR_HVBAT_CELL_V_059Confirmed

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #60 FORMENTOR_HVBAT_CELL_V_060Confirmed

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #61 FORMENTOR_HVBAT_CELL_V_061Confirmed

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #62 FORMENTOR_HVBAT_CELL_V_062Confirmed

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #63 FORMENTOR_HVBAT_CELL_V_063Confirmed

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #64 FORMENTOR_HVBAT_CELL_V_064Confirmed

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #65 FORMENTOR_HVBAT_CELL_V_065Confirmed

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #66 FORMENTOR_HVBAT_CELL_V_066Confirmed

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #67 FORMENTOR_HVBAT_CELL_V_067Confirmed

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #68 FORMENTOR_HVBAT_CELL_V_068Confirmed

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #69 FORMENTOR_HVBAT_CELL_V_069Confirmed

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #70 FORMENTOR_HVBAT_CELL_V_070Confirmed

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #71 FORMENTOR_HVBAT_CELL_V_071Confirmed

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #72 FORMENTOR_HVBAT_CELL_V_072Confirmed

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #73 FORMENTOR_HVBAT_CELL_V_073Confirmed

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #74 FORMENTOR_HVBAT_CELL_V_074Confirmed

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #75 FORMENTOR_HVBAT_CELL_V_075Confirmed

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #76 FORMENTOR_HVBAT_CELL_V_076Confirmed

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #77 FORMENTOR_HVBAT_CELL_V_077Confirmed

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #78 FORMENTOR_HVBAT_CELL_V_078Confirmed

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #79 FORMENTOR_HVBAT_CELL_V_079Confirmed

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #80 FORMENTOR_HVBAT_CELL_V_080Confirmed

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #81 FORMENTOR_HVBAT_CELL_V_081Confirmed

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #82 FORMENTOR_HVBAT_CELL_V_082Confirmed

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #83 FORMENTOR_HVBAT_CELL_V_083Confirmed

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #84 FORMENTOR_HVBAT_CELL_V_084Confirmed

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #85 FORMENTOR_HVBAT_CELL_V_085Confirmed

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #86 FORMENTOR_HVBAT_CELL_V_086Confirmed

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #87 FORMENTOR_HVBAT_CELL_V_087Confirmed

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #88 FORMENTOR_HVBAT_CELL_V_088Confirmed

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #89 FORMENTOR_HVBAT_CELL_V_089Confirmed

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #90 FORMENTOR_HVBAT_CELL_V_090Confirmed

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #91 FORMENTOR_HVBAT_CELL_V_091Confirmed

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #92 FORMENTOR_HVBAT_CELL_V_092Confirmed

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #93 FORMENTOR_HVBAT_CELL_V_093Confirmed

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #94 FORMENTOR_HVBAT_CELL_V_094Confirmed

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #95 FORMENTOR_HVBAT_CELL_V_095Confirmed

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #96 FORMENTOR_HVBAT_CELL_V_096Confirmed

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Internal

Average battery consumption FORMENTOR_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x14 = 20 → 20 A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Estimated electric power reserve FORMENTOR_RANGE_EST_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0062 = 98 → 98 km

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Modules

HV battery module temperature, #5 FORMENTOR_HVBAT_MOD_T_5Confirmed

  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #6 FORMENTOR_HVBAT_MOD_T_6Confirmed

  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #7 FORMENTOR_HVBAT_MOD_T_7Confirmed

  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #8 FORMENTOR_HVBAT_MOD_T_8Confirmed

  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Climate

A/C compressor power, actual FORMENTOR_AC_CMPR_PWR_ACTConfirmed

  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2024

Example reply from a 2026 Cupra Formentor.

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

0x0000 = 0 → 0 W

Confirmed for 2025 to 2026. Not supported for 2022 to 2024.

A/C refrigerant pressure, sensor 1 FORMENTOR_AC_REFRIG_P_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8810000
Range
0 to 576.708 bar
Unit
bar

0x028A = 650 → 650×8810000 = 5.72 bar

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

A/C refrigerant temperature, sensor 1 FORMENTOR_AC_REFRIG_T_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 369.4 °C
Unit
°C

0x027C = 636 → 636×10100−40 = 23.6 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

A/C refrigerant temperature, sensor 1 interior FORMENTOR_AC_REFRIG_T_SENS1_INTConfirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 369.4 °C
Unit
°C

0x0296 = 662 → 662×10100−40 = 26.2 °C

Confirmed for 2025 to 2026. In testing for 2020 to 2021. Supported for 2022 to 2024.

Cabin humidity FORMENTOR_CABIN_HUMIDITYConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x6A = 106 → 1062 = 53 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

CO2 content interior FORMENTOR_CABIN_CO2Confirmed

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

0xFE = 254 → 254×100 = 25,400

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

Outside temperature FORMENTOR_AATConfirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x8E = 142 → 1422−50 = 21 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Recirculation flap actual position FORMENTOR_MQB_RECIRC_FLAP_ACTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0279 = 633 → 633

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Recirculation flap fresh air threshold FORMENTOR_MQB_RECIRC_FLAP_FRESH_THRConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00A3 = 163 → 163

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Recirculation flap target position FORMENTOR_MQB_RECIRC_FLAP_TRGConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0278 = 632 → 632

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Recirculation flap threshold FORMENTOR_MQB_RECIRC_FLAP_THRConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x035A = 858 → 858

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Windshield temperature FORMENTOR_WINDSHIELD_TConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

0x82 = 130 → 130×0.576−38.8 = 36.08 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Control

Absolute pedal position, drive FORMENTOR_APP_DConfirmed

  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.55 = 0 %

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2021 to 2024, 2026.

Brake pressure FORMENTOR_BRAKE_PRESConfirmed

  • Service 22DID 105C
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Hydraulic brake booster: active FORMENTOR_HYD_BRAKE_BOOST_ACTIVEConfirmed

  • Service 22DID 1810
  • Module713 → 77D
  • Every2 s
  • Testing for 2020 to 2024

Example reply from a 2026 Cupra Formentor.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2025 to 2026. Not supported for 2022 to 2024.

Drivetrain

All-wheel drive current FORMENTOR_PQ35_HAL_IConfirmed

  • Service 22DID 2BE6
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 A
Unit
A

0x0000 = 0 → 01000 = 0 A

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

All-wheel drive duty cycle FORMENTOR_PQ35_HAL_DUTYConfirmed

  • Service 22DID 2BF3
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100.39255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100.39255 = 0 %

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

All-wheel drive mode FORMENTOR_PQ35_HAL_MODEConfirmed

  • Service 22DID 0C0A
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

All-wheel drive pulse width modulation FORMENTOR_PQ35_HAL_PWMConfirmed

  • Service 22DID 2BE7
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x35 = 53 → 53 %

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022, 2024 to 2025. Supported for 2021, 2023, 2026.

Engine

A/C clutch FORMENTOR_CLIMATE_A_C_CLCHConfirmed

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

A/C compressor load FORMENTOR_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x00 = 0 → 010 = 0 N·m

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

A/C compressor torque FORMENTOR_A_C_COMPRESSOR_TORQUE_V2Confirmed

  • Service 22DID 101A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

A/C refrigerant pressure FORMENTOR_A_C_REFRIGERANT_PRES_V2Confirmed

  • Service 22DID 1017
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2022, 2025. Supported for 2021, 2023 to 2024, 2026.

Adaptive mode FORMENTOR_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Air pollution level FORMENTOR_CLIMATE_AIR_POLUTION_LVLConfirmed

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7
Unit
Number

0x0D = 13 → 1310 = 1.3

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Ambient air temperature FORMENTOR_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x90 = 144 → 1442−50 = 22 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Automatic transmission fluid temperature, variant 2 FORMENTOR_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x0E = 14 → 14−40 = -26 °C

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Aux. hydraulic pump internal temperature FORMENTOR_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Aux. hydraulic pump, current FORMENTOR_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2020 to 2024, 2026. Not supported for 2025.

Cabin temperature FORMENTOR_CABIN_TConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x014C = 332 → 33210 = 33.2 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Control module temperature FORMENTOR_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Coolant fan 1, activation FORMENTOR_COOLANT_FAN_1_ACTIVATION_V2Confirmed

  • Service 22DID 1130
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Coolant temperature at engine start FORMENTOR_COOLANT_T_AT_ENGINE_START_V2Confirmed

  • Service 22DID 1291
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Coolant temperature at radiator output, specified value FORMENTOR_COOLANT_T_AT_RADIATOR_OUTPUT_SPECIFIED_VALUEConfirmed

  • Service 22DID 1135
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Current N215 pressure control valve 1 FORMENTOR_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

Current N216 pressure control valve 2 FORMENTOR_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

Current N218 pressure control valve 4 FORMENTOR_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

Current N233 pressure control valve 5 FORMENTOR_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

Current solenoid FORMENTOR_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

Current type of driver counter FORMENTOR_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Desired torque raw FORMENTOR_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Driving mode sensor, hall sensor a FORMENTOR_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Driving position FORMENTOR_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Driving resistance index FORMENTOR_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Electric motor non-vehicle power limitation FORMENTOR_EM_NV_PWR_LIMConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

0xB2 = 178 → 178×50 = 8,900 W

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Electric motor power limitation FORMENTOR_EM_PWR_LIMConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0001 = 1 → 1×50 = 50 W

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Engine oil temperature FORMENTOR_EOT_FC00Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 11BD
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2025. Supported for 2021 to 2024, 2026.

Engine torque FORMENTOR_ENGINE_TORQUE_V2Confirmed

  • Service 22DID 1010
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Excessive temperature protection FORMENTOR_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Front left deflector temperature FORMENTOR_CLIMATE_FR_L_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x78 = 120 → 1203 = 40 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Front left temperature flap actual value FORMENTOR_CLIMATE_FR_L_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x51 = 81 → 812 = 40.5 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Front right deflector temperature FORMENTOR_CLIMATE_FR_R_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x78 = 120 → 1203 = 40 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Front right temperature flap actual value FORMENTOR_CLIMATE_FR_R_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x2B = 43 → 432 = 21.5 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Generator performance FORMENTOR_GENERATOR_PERFORMANCE_V2Confirmed

  • Service 22DID 1097
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.4216 W
Unit
W

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Hill descent control FORMENTOR_HDC_ACTIVEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

Hill descent control, incline FORMENTOR_HDC_INCLINEConfirmed

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x18 = 24 → 24 %

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

ID of current driving program FORMENTOR_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Leg deflector temperature FORMENTOR_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x82 = 130 → 1303 = 43.333333 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

M009, desired solenoid out 10 FORMENTOR_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2024, 2026. Not supported for 2025.

M009, desired solenoid out 11 FORMENTOR_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2024, 2026. Not supported for 2025.

M009, desired solenoid out 12 FORMENTOR_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2024, 2026. Not supported for 2025.

M009, desired solenoid out 13 FORMENTOR_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2024, 2026. Not supported for 2025.

M009, desired solenoid out 14 FORMENTOR_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2024, 2026. Not supported for 2025.

Main catalytic converter oxygen storage capacity age correction factor FORMENTOR_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR_V2Confirmed

  • Service 22DID 14F9
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Max permissible engine torque FORMENTOR_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Misfires, cylinder 1 FORMENTOR_MISFIRES_C1_FC00Confirmed

  • Service 22DID 2966
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires, cylinder 2 FORMENTOR_MISFIRES_C2_V2Confirmed

  • Service 22DID 2969
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires, cylinder 3 FORMENTOR_MISFIRES_C3_FC00Confirmed

  • Service 22DID 2967
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires, cylinder 4 FORMENTOR_MISFIRES_C4_V2Confirmed

  • Service 22DID 2968
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Oil thermal wear FORMENTOR_DASH_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x001A = 26 → 26 km

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Outside temperature FORMENTOR_OUTSIDE_TConfirmed

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing for 2020 to 2021, 2023 to 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x8E = 142 → 1422−50 = 21 °C

Confirmed for 2022, 2025 to 2026. In testing for 2020 to 2021, 2023 to 2024.

Outside temperature, system calculated FORMENTOR_OUTSIDE_T_SYSTEMConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

0x8E = -114 → -1142 = -57 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Radiator fan actual duty FORMENTOR_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x0A = 10 → 102.5 = 4 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Radiator fan commanded duty FORMENTOR_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Rear deflector temperature FORMENTOR_CLIMATE_RR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x79 = 121 → 1213 = 40.333333 °C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Refrigerant pressure FORMENTOR_CLIMATE_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x1E = 30 → 305 = 6 bar

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Reserve torque FORMENTOR_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Route data, active FORMENTOR_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Temperature after evaporator FORMENTOR_CLIMATE_T_AFTER_EVAPConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2020 to 2021

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val3
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Time in run-on after shutdown FORMENTOR_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2020 to 2024, 2026. Not supported for 2025.

Time since reset FORMENTOR_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque factor FORMENTOR_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque transmitting function, ratio FORMENTOR_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Fuel

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2022 to 2025. Supported for 2026.

Fuel level FORMENTOR_FLI_FC00Confirmed

  • Service 22DID 14B4
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 L
Unit
L

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Fuel tank fill level FORMENTOR_FUEL_TANK_FILL_LEVEL_V2Confirmed

  • Service 22DID 24FC
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2025. Supported for 2021, 2023 to 2024, 2026.

GPS

Satellites, tracked FORMENTOR_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x10 = 16 → 16

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Satellites, visible FORMENTOR_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Movement

A/C compressor speed FORMENTOR_CLIMATE_A_C_COMP_SPDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Acceleration FORMENTOR_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2020 to 2024, 2026. Not supported for 2025.

Acceleration FORMENTOR_ACCELERATION_29BIT_V2Confirmed

  • Service 22DID 12B0
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Acceleration or deceleration mode FORMENTOR_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Accelerator pedal position FORMENTOR_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

All-wheel drive front-rear speed differential FORMENTOR_PQ35_HAL_F_R_VSS_DIFFConfirmed

  • Service 22DID 2BF0
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Aux. hydraulic pump RPM FORMENTOR_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2020 to 2024, 2026. Not supported for 2025.

Camshaft speed FORMENTOR_CAMSHAFT_VSS_V2Confirmed

  • Service 22DID 1124
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Engine RPM at idle required FORMENTOR_ENGINE_RPM_AT_IDLE_REQUIRED_V2Confirmed

  • Service 22DID 1161
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Front left wheel speed FORMENTOR_FL_VSS_V2Confirmed

  • Service 22DID 1800
  • Module713 → 77D
  • Every250 ms
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Front left wheel speed FORMENTOR_PQ35_FL_VSSConfirmed

  • Service 22DID 2B1B
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Front right wheel speed FORMENTOR_FR_VSS_V2Confirmed

  • Service 22DID 1801
  • Module713 → 77D
  • Every250 ms
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Front right wheel speed FORMENTOR_PQ35_FR_VSSConfirmed

  • Service 22DID 2B1C
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Front right wheel speed FORMENTOR_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Longitudinal acceleration, raw FORMENTOR_LONGTITUDINAL_ACCELERATION_RAW_VALUE_V2Confirmed

  • Service 22DID 15CF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires/1000 rpm, cylinder 1 FORMENTOR_MISFIRES_1000_RPM_C1_V2Confirmed

  • Service 22DID 291D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires/1000 rpm, cylinder 2 FORMENTOR_MISFIRES_1000_RPM_C2_V2Confirmed

  • Service 22DID 2920
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires/1000 rpm, cylinder 3 FORMENTOR_MISFIRES_1000_RPM_C3_V2Confirmed

  • Service 22DID 291E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Misfires/1000 rpm, cylinder 4 FORMENTOR_MISFIRES_1000_RPM_C4_V2Confirmed

  • Service 22DID 291F
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Motor RPM FORMENTOR_ELDRIVE_MOTOR_RPMConfirmed

  • Service 22DID F40C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Rear left wheel speed FORMENTOR_PQ35_RL_VSSConfirmed

  • Service 22DID 2B1D
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Rear left wheel speed FORMENTOR_RL_VSS_V2Confirmed

  • Service 22DID 1802
  • Module713 → 77D
  • Every250 ms
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Rear left wheel speed FORMENTOR_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0002 = 2 → 210 = 0.2 km/h

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Rear right wheel speed FORMENTOR_PQ35_RR_VSSConfirmed

  • Service 22DID 2B1E
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Rear right wheel speed FORMENTOR_RR_VSS_V2Confirmed

  • Service 22DID 1803
  • Module713 → 77D
  • Every250 ms
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Vehicle lateral acceleration, raw value FORMENTOR_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE_V2Confirmed

  • Service 22DID 15D1
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Vehicle speed FORMENTOR_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Vehicle speed FORMENTOR_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022, 2025. Supported for 2021, 2023 to 2024, 2026.

Vehicle speed ESP FORMENTOR_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Vehicle speed, HR FORMENTOR_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2024. Supported for 2021 to 2023, 2025 to 2026.

Stats

Crashes, driver side FORMENTOR_CRASH_DRVRConfirmed

  • Service 22DID 2354
  • Module715 → 77F
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Crashes, front FORMENTOR_CRASH_FRONTConfirmed

  • Service 22DID 2353
  • Module715 → 77F
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Crashes, passenger side FORMENTOR_CRASH_PASSConfirmed

  • Service 22DID 2355
  • Module715 → 77F
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Crashes, rear FORMENTOR_CRASH_REARConfirmed

  • Service 22DID 2356
  • Module715 → 77F
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Rollovers FORMENTOR_ROLLOVERConfirmed

  • Service 22DID 2357
  • Module715 → 77F
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Tires

Front left wheel speed FORMENTOR_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Front right wheel speed FORMENTOR_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Rear left wheel speed FORMENTOR_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Rear right wheel speed FORMENTOR_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Steering wheel angle FORMENTOR_MQB_SWAConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every250 ms
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8+0.06
Range
-4095.94 to 4095.935 °
Unit
°

0x16D5 = 5845 → 58458+0.06 = 730.685 °

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Steering wheel torque sensor 1 FORMENTOR_STEER_WHL_TQ_SENS_1Confirmed

  • Service 22DID 1805
  • Module712 → 77C
  • Every250 ms
  • Testing for 2020 to 2021, 2023 to 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

0x00C6 = 198 → 198×0.004395+0.06 = 0.93021 °

Confirmed for 2022, 2025 to 2026. In testing for 2020 to 2021, 2023 to 2024.

Transmission

Adaptation counter PF lockup clutch FORMENTOR_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch a FORMENTOR_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch b FORMENTOR_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch c FORMENTOR_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch d FORMENTOR_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch e FORMENTOR_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch a FORMENTOR_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch b FORMENTOR_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch c FORMENTOR_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch d FORMENTOR_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch e FORMENTOR_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation inflation current PF lockup clutch FORMENTOR_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

All-wheel drive clutch blockage degree FORMENTOR_MQB_HAL_CLUTCH_BLOCKConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bit 15 of the reply.

Formula
val×8
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0×8 = 0

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

All-wheel drive clutch fully open FORMENTOR_MQB_HAL_CLUTCH_OPENConfirmed

  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Clutch 1 lower adaptation point FORMENTOR_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 1 nominal pressure FORMENTOR_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 1 upper adaptation point FORMENTOR_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 2 lower adaptation point FORMENTOR_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 2 upper adaptation point FORMENTOR_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch overheating, clutch FORMENTOR_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch temperature FORMENTOR_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Dynamic shift program FORMENTOR_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch a FORMENTOR_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch b FORMENTOR_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch c FORMENTOR_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch d FORMENTOR_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch e FORMENTOR_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch a FORMENTOR_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch b FORMENTOR_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch c FORMENTOR_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch d FORMENTOR_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch e FORMENTOR_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Launch control counter, clutch 1 FORMENTOR_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Shift in progress, selected gear FORMENTOR_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Shift in progress, target gear FORMENTOR_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Specified torque clutch 1 - data FORMENTOR_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Specified torque clutch 2 - data FORMENTOR_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Time since shift FORMENTOR_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter amplification FORMENTOR_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter lockup clutch adaptation count FORMENTOR_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter lockup clutch fill time adaptation FORMENTOR_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission drag torque FORMENTOR_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission fluid temperature 2 FORMENTOR_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission torque losses FORMENTOR_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Trips

Average consumption, category 0 FORMENTOR_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0095 = 149 → 14910 = 14.9 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 1 FORMENTOR_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0073 = 115 → 11510 = 11.5 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 2 FORMENTOR_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008F = 143 → 14310 = 14.3 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 3 FORMENTOR_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x007C = 124 → 12410 = 12.4 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 4 FORMENTOR_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0085 = 133 → 13310 = 13.3 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 5 FORMENTOR_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00A7 = 167 → 16710 = 16.7 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Average consumption, category 6 FORMENTOR_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Distance to empty FORMENTOR_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2021. Not supported for 2022 to 2026.

Engine control unit distance driven FORMENTOR_ECU_DIST_DRIVENConfirmed

  • Service 22DID 1160
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Odometer FORMENTOR_MQB_TCM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x0001EA03 = 125443 → 12544310 = 12,544.3 km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer FORMENTOR_ODO_3

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2024, 2026. Not supported for 2025.

Odometer FORMENTOR_PQ35_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every30 s
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0069A4 = 27044 → 27,044 km

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2025.

Odometer #2 FORMENTOR_MQB_TCM_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer #3 FORMENTOR_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x003000 = 12288 → 12,288 km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer, mileage, HR FORMENTOR_ODO_MILEAGE_HRConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing for 2020 to 2021, 2023 to 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

0x0029B927 = 2734375 → 27343751000 = 2,734.375 km

Confirmed for 2022, 2025 to 2026. In testing for 2020 to 2021, 2023 to 2024.

Range remaining FORMENTOR_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x00C6 = 198 → 198 mi

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Torque converter time in temperature range 1 FORMENTOR_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 2 FORMENTOR_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 3 FORMENTOR_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 4 FORMENTOR_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 5 FORMENTOR_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 6 FORMENTOR_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 7 FORMENTOR_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter time in temperature range 8 FORMENTOR_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2020 to 2024, 2026. Not supported for 2025.

Vehicle distance driven FORMENTOR_VEHICLE_DIST_DRIVENConfirmed

  • Service 22DID 10E0
  • ModuleFC00 → FE0076
  • Every30 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.