Parameters
The Cupra Tavascan has 258 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery adapted capacity TAVASCAN_AUX_BAT_CAPConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 Ah
- Unit
- Ah
0x2E = 46 → 46 Ah
Confirmed for 2025. In testing for 2024, 2026.
12V battery aging by capacity TAVASCAN_AUX_BAT_AGE_CAPConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x5B = 91 → 91 %
Confirmed for 2025. In testing for 2024, 2026.
12V battery aging by power TAVASCAN_AUX_BAT_AGE_POWConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x58 = 88 → 88 %
Confirmed for 2025. In testing for 2024, 2026.
12V battery current TAVASCAN_AUX_BAT_CConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 47 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -1000000 to 1000000 A
- Unit
- A
0x00000078 = 120 → = 0.12 A
Confirmed for 2025. In testing for 2024, 2026.
12V battery soc TAVASCAN_AUX_BAT_SOCConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x63 = 99 → 99 %
Confirmed for 2025. In testing for 2024, 2026.
12V battery total charge TAVASCAN_AUX_BAT_CHRG_TOTConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 96 to 127 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
0x000007ED = 2029 → = 202.9 Ah
Confirmed for 2025. In testing for 2024, 2026.
12V battery total discharge TAVASCAN_AUX_BAT_DSCH_TOTConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 128 to 159 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
0x00000609 = 1545 → = 154.5 Ah
Confirmed for 2025. In testing for 2024, 2026.
12V battery voltage TAVASCAN_AUX_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 69 V
- Unit
- V
0x26C9 = 9929 → = 13.929 V
Confirmed for 2025. In testing for 2024, 2026.
AC charging TAVASCAN_AC_CHARGINGConfirmed
- Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2024, 2026.
Average battery consumption TAVASCAN_HVBAT_CSMP_AVG_INTConfirmed
- Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
0x3D = 61 → 61 A
Confirmed for 2025. In testing for 2024, 2026.
Battery cell soc max, ID TAVASCAN_HVBAT_CELL_SOC_MAX_IDConfirmed
- Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
Battery cell soc min, ID TAVASCAN_HVBAT_CELL_SOC_MIN_IDConfirmed
- Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
Battery cell soc, maximum TAVASCAN_HVBAT_CELL_SOC_MAXConfirmed
- Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Battery cell soc, minimum TAVASCAN_HVBAT_CELL_SOC_MINConfirmed
- Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Battery current limit, charging TAVASCAN_HVBAT_I_LIM_CHGConfirmed
- Service 22
DID 1E1B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
Battery current limit, discharging TAVASCAN_HVBAT_I_LIM_DSCHConfirmed
- Service 22
DID 1E1C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
Battery current, DC, alternate TAVASCAN_HVBAT_I_DC_2Confirmed
- Service 22
DID 1E3E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -1500 to 42948172.95 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
Battery current, motor controller TAVASCAN_HVBAT_I_ENGConfirmed
- Service 22
DID 035E - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
Battery heater current TAVASCAN_HVBAT_PTC_IConfirmed
- Service 22
DID 1620 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
Battery heater temperature, #1 TAVASCAN_HVBAT_PTC_T_1Confirmed
- Service 22
DID 1623 - Module
FC00 → FE007B - Every
5 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery heater temperature, #2 TAVASCAN_HVBAT_PTC_T_2Confirmed
- Service 22
DID 1624 - Module
FC00 → FE007B - Every
5 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery heater voltage TAVASCAN_HVBAT_PTC_VConfirmed
- Service 22
DID 1621 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, inlet TAVASCAN_HVBAT_T_INConfirmed
- Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, max TAVASCAN_HVBAT_T_MAX_V2Confirmed
- Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, max sensor ID TAVASCAN_HVBAT_T_MAX_IDConfirmed
- Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, min TAVASCAN_HVBAT_T_MINConfirmed
- Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, min sensor ID TAVASCAN_HVBAT_T_MIN_IDConfirmed
- Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
Battery temperature, outlet TAVASCAN_HVBAT_T_OUTConfirmed
- Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Battery voltage, after main switch TAVASCAN_HVBAT_V_AFTERConfirmed
- Service 22
DID 1E38 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.967 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Battery voltage, before main switch TAVASCAN_HVBAT_V_BEFOREConfirmed
- Service 22
DID 1E36 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.967 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Battery voltage, charging TAVASCAN_HVBAT_V_CHGConfirmed
- Service 22
DID 1E39 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1023.999 to 1023.967 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Battery voltage, sum of all cells TAVASCAN_HVBAT_V_CELLS_SUMConfirmed
- Service 22
DID 1E3C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -524288 to 524287.99 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Battery voltage, traction mode TAVASCAN_HVBAT_V_TRACConfirmed
- Service 22
DID 4675 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Charge voltage, max TAVASCAN_MAXIMUM_CHARGE_VConfirmed
- Service 22
DID 5171 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Charging, rapid? TAVASCAN_RAPID_CHARGE_PORTConfirmed
- Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2024, 2026.
Control module temperature TAVASCAN_HVBAT_ECU_TConfirmed
- Service 22
DID 1622 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Current gear TAVASCAN_DRIVE_MODEConfirmed
- Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bit 7 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | DRIVING | Driving |
Confirmed for 2025. In testing for 2024, 2026.
DC battery voltage TAVASCAN_DC_BATTERY_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1E3B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
DC-DC converter coolant temperature TAVASCAN_DCDC_T_COOLConfirmed
- Service 22
DID 43B8 - Module
FC00 → FE0076 - Every
5 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
DC-DC converter, current TAVASCAN_DCDC_IConfirmed
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 A
- Unit
- A
0x0211 = 529 → = 18 A
Confirmed for 2025. In testing for 2024, 2026.
DC-DC converter, low voltage TAVASCAN_DCDC_V_LOWConfirmed
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x8C = 140 → = 14 V
Confirmed for 2025. In testing for 2024, 2026.
DC-DC converter, reserved current TAVASCAN_DCDC_I_RSVConfirmed
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 A
- Unit
- A
0x029B = 667 → = 156 A
Confirmed for 2025. In testing for 2024, 2026.
Discharge voltage, min TAVASCAN_MINIMUM_DISCHARGE_VConfirmed
- Service 22
DID 5170 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
ECall battery charge level TAVASCAN_ECALL_SOCConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x50 = 80 → 80 %
Confirmed for 2025. In testing for 2024, 2026.
Ecall battery charge status TAVASCAN_ECALL_BATTERY_CHARGE_STATUSConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x02 = 2 → 2
Confirmed for 2025. In testing for 2024, 2026.
Estimated electric power reserve TAVASCAN_RANGE_RESERVE_ESTConfirmed
- Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x00A6 = 166 → 166 km
Confirmed for 2025. In testing for 2024, 2026.
Estimated reserve range TAVASCAN_RANGE_EST_CANConfirmed
- Service 22
DID 2AB5 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x00A6 = 166 → 166 km
Confirmed for 2025. In testing for 2024, 2026.
HV auxiliary current total TAVASCAN_HVAUX_IConfirmed
- Service 22
DID 0360 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
HV auxiliary power TAVASCAN_HVAUX_PWRConfirmed
- Service 22
DID 0364 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kW
- Unit
- kW
Confirmed for 2025. In testing for 2024, 2026.
HV battery after contacts voltage TAVASCAN_HVBAT_AFTER_CONTACTS_VConfirmed
- Service 22
DID 189B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1000 to 31767.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage max, ID TAVASCAN_HVBAT_CELL_V_MAX_IDConfirmed
- Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage min, ID TAVASCAN_HVBAT_CELL_V_MIN_IDConfirmed
- Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, maximum TAVASCAN_HVBAT_CELL_V_MAX_V2Confirmed
- Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, minimum TAVASCAN_HVBAT_CELL_V_MIN_V2Confirmed
- Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery energy TAVASCAN_HVBAT_KWHConfirmed
Energy stored in the high voltage battery
- Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638 kWh
- Unit
- kWh
0x0544 = 1348 → = 33.7 kWh
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #1 TAVASCAN_HVBAT_MOD_T_1Confirmed
- Service 22
DID 1EAE - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #2 TAVASCAN_HVBAT_MOD_T_2Confirmed
- Service 22
DID 1EAF - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #3 TAVASCAN_HVBAT_MOD_T_3Confirmed
- Service 22
DID 1EB0 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #4 TAVASCAN_HVBAT_MOD_T_4Confirmed
- Service 22
DID 1EB1 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #17 TAVASCAN_HVBAT_MOD_T_17Confirmed
- Service 22
DID 7425 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #18 TAVASCAN_HVBAT_MOD_T_18Confirmed
- Service 22
DID 7426 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #19 TAVASCAN_HVBAT_MOD_T_19Confirmed
- Service 22
DID 7427 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #20 TAVASCAN_HVBAT_MOD_T_20Confirmed
- Service 22
DID 7428 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #21 TAVASCAN_HVBAT_MOD_T_21Confirmed
- Service 22
DID 7429 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #22 TAVASCAN_HVBAT_MOD_T_22Confirmed
- Service 22
DID 742A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #23 TAVASCAN_HVBAT_MOD_T_23Confirmed
- Service 22
DID 742B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #24 TAVASCAN_HVBAT_MOD_T_24Confirmed
- Service 22
DID 742C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery, max energy TAVASCAN_HVBAT_CAPConfirmed
- Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 kWh
- Unit
- kWh
0x060B = 1547 → = 77.35 kWh
Confirmed for 2025. In testing for 2024, 2026.
HV battery: circulation pump flow TAVASCAN_CIRC_PUMP_FLOWConfirmed
- Service 22
DID 743B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Start/stop battery resistance TAVASCAN_SSB_RConfirmed
- Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 mΩ
- Unit
- mΩ
0x00 = 0 → = 0 mΩ
Confirmed for 2025. In testing for 2024, 2026.
State of charge TAVASCAN_SOC_FC00Confirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 3DEF - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
State of charge TAVASCAN_SOC_V2Confirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 028C - Module
FC00 → FE007B - Every
250 ms - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Temperature, 12V battery TAVASCAN_AUX_BAT_TConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x33 = 51 → = 11 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, 12V battery sensor TAVASCAN_AUX_BAT_T_SConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x34 = 52 → = 12 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, battery TAVASCAN_BATTERY_TConfirmed
- Service 22
DID 2A0B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Cells
HV battery cell voltage, #1 TAVASCAN_HVBAT_CELL_V_001Confirmed
- Service 22
DID 1E40 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #2 TAVASCAN_HVBAT_CELL_V_002Confirmed
- Service 22
DID 1E41 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #3 TAVASCAN_HVBAT_CELL_V_003Confirmed
- Service 22
DID 1E42 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #4 TAVASCAN_HVBAT_CELL_V_004Confirmed
- Service 22
DID 1E43 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #5 TAVASCAN_HVBAT_CELL_V_005Confirmed
- Service 22
DID 1E44 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #6 TAVASCAN_HVBAT_CELL_V_006Confirmed
- Service 22
DID 1E45 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #7 TAVASCAN_HVBAT_CELL_V_007Confirmed
- Service 22
DID 1E46 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #8 TAVASCAN_HVBAT_CELL_V_008Confirmed
- Service 22
DID 1E47 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #9 TAVASCAN_HVBAT_CELL_V_009Confirmed
- Service 22
DID 1E48 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #10 TAVASCAN_HVBAT_CELL_V_010Confirmed
- Service 22
DID 1E49 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #11 TAVASCAN_HVBAT_CELL_V_011Confirmed
- Service 22
DID 1E4A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #12 TAVASCAN_HVBAT_CELL_V_012Confirmed
- Service 22
DID 1E4B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #13 TAVASCAN_HVBAT_CELL_V_013Confirmed
- Service 22
DID 1E4C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #14 TAVASCAN_HVBAT_CELL_V_014Confirmed
- Service 22
DID 1E4D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #15 TAVASCAN_HVBAT_CELL_V_015Confirmed
- Service 22
DID 1E4E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #16 TAVASCAN_HVBAT_CELL_V_016Confirmed
- Service 22
DID 1E4F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #17 TAVASCAN_HVBAT_CELL_V_017Confirmed
- Service 22
DID 1E50 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #18 TAVASCAN_HVBAT_CELL_V_018Confirmed
- Service 22
DID 1E51 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #19 TAVASCAN_HVBAT_CELL_V_019Confirmed
- Service 22
DID 1E52 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #20 TAVASCAN_HVBAT_CELL_V_020Confirmed
- Service 22
DID 1E53 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #21 TAVASCAN_HVBAT_CELL_V_021Confirmed
- Service 22
DID 1E54 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #22 TAVASCAN_HVBAT_CELL_V_022Confirmed
- Service 22
DID 1E55 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #23 TAVASCAN_HVBAT_CELL_V_023Confirmed
- Service 22
DID 1E56 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #24 TAVASCAN_HVBAT_CELL_V_024Confirmed
- Service 22
DID 1E57 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #25 TAVASCAN_HVBAT_CELL_V_025Confirmed
- Service 22
DID 1E58 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #26 TAVASCAN_HVBAT_CELL_V_026Confirmed
- Service 22
DID 1E59 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #27 TAVASCAN_HVBAT_CELL_V_027Confirmed
- Service 22
DID 1E5A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #28 TAVASCAN_HVBAT_CELL_V_028Confirmed
- Service 22
DID 1E5B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #29 TAVASCAN_HVBAT_CELL_V_029Confirmed
- Service 22
DID 1E5C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #30 TAVASCAN_HVBAT_CELL_V_030Confirmed
- Service 22
DID 1E5D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #31 TAVASCAN_HVBAT_CELL_V_031Confirmed
- Service 22
DID 1E5E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #32 TAVASCAN_HVBAT_CELL_V_032Confirmed
- Service 22
DID 1E5F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #33 TAVASCAN_HVBAT_CELL_V_033Confirmed
- Service 22
DID 1E60 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #34 TAVASCAN_HVBAT_CELL_V_034Confirmed
- Service 22
DID 1E61 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #35 TAVASCAN_HVBAT_CELL_V_035Confirmed
- Service 22
DID 1E62 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #36 TAVASCAN_HVBAT_CELL_V_036Confirmed
- Service 22
DID 1E63 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #37 TAVASCAN_HVBAT_CELL_V_037Confirmed
- Service 22
DID 1E64 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #38 TAVASCAN_HVBAT_CELL_V_038Confirmed
- Service 22
DID 1E65 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #39 TAVASCAN_HVBAT_CELL_V_039Confirmed
- Service 22
DID 1E66 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #40 TAVASCAN_HVBAT_CELL_V_040Confirmed
- Service 22
DID 1E67 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #41 TAVASCAN_HVBAT_CELL_V_041Confirmed
- Service 22
DID 1E68 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #42 TAVASCAN_HVBAT_CELL_V_042Confirmed
- Service 22
DID 1E69 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #43 TAVASCAN_HVBAT_CELL_V_043Confirmed
- Service 22
DID 1E6A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #44 TAVASCAN_HVBAT_CELL_V_044Confirmed
- Service 22
DID 1E6B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #45 TAVASCAN_HVBAT_CELL_V_045Confirmed
- Service 22
DID 1E6C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #46 TAVASCAN_HVBAT_CELL_V_046Confirmed
- Service 22
DID 1E6D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #47 TAVASCAN_HVBAT_CELL_V_047Confirmed
- Service 22
DID 1E6E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #48 TAVASCAN_HVBAT_CELL_V_048Confirmed
- Service 22
DID 1E6F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #49 TAVASCAN_HVBAT_CELL_V_049Confirmed
- Service 22
DID 1E70 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #50 TAVASCAN_HVBAT_CELL_V_050Confirmed
- Service 22
DID 1E71 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #51 TAVASCAN_HVBAT_CELL_V_051Confirmed
- Service 22
DID 1E72 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #52 TAVASCAN_HVBAT_CELL_V_052Confirmed
- Service 22
DID 1E73 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #53 TAVASCAN_HVBAT_CELL_V_053Confirmed
- Service 22
DID 1E74 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #54 TAVASCAN_HVBAT_CELL_V_054Confirmed
- Service 22
DID 1E75 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #55 TAVASCAN_HVBAT_CELL_V_055Confirmed
- Service 22
DID 1E76 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #56 TAVASCAN_HVBAT_CELL_V_056Confirmed
- Service 22
DID 1E77 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #57 TAVASCAN_HVBAT_CELL_V_057Confirmed
- Service 22
DID 1E78 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #58 TAVASCAN_HVBAT_CELL_V_058Confirmed
- Service 22
DID 1E79 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #59 TAVASCAN_HVBAT_CELL_V_059Confirmed
- Service 22
DID 1E7A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #60 TAVASCAN_HVBAT_CELL_V_060Confirmed
- Service 22
DID 1E7B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #61 TAVASCAN_HVBAT_CELL_V_061Confirmed
- Service 22
DID 1E7C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #62 TAVASCAN_HVBAT_CELL_V_062Confirmed
- Service 22
DID 1E7D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #63 TAVASCAN_HVBAT_CELL_V_063Confirmed
- Service 22
DID 1E7E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #64 TAVASCAN_HVBAT_CELL_V_064Confirmed
- Service 22
DID 1E7F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #65 TAVASCAN_HVBAT_CELL_V_065Confirmed
- Service 22
DID 1E80 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #66 TAVASCAN_HVBAT_CELL_V_066Confirmed
- Service 22
DID 1E81 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #67 TAVASCAN_HVBAT_CELL_V_067Confirmed
- Service 22
DID 1E82 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #68 TAVASCAN_HVBAT_CELL_V_068Confirmed
- Service 22
DID 1E83 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #69 TAVASCAN_HVBAT_CELL_V_069Confirmed
- Service 22
DID 1E84 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #70 TAVASCAN_HVBAT_CELL_V_070Confirmed
- Service 22
DID 1E85 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #71 TAVASCAN_HVBAT_CELL_V_071Confirmed
- Service 22
DID 1E86 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #72 TAVASCAN_HVBAT_CELL_V_072Confirmed
- Service 22
DID 1E87 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #73 TAVASCAN_HVBAT_CELL_V_073Confirmed
- Service 22
DID 1E88 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #74 TAVASCAN_HVBAT_CELL_V_074Confirmed
- Service 22
DID 1E89 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #75 TAVASCAN_HVBAT_CELL_V_075Confirmed
- Service 22
DID 1E8A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #76 TAVASCAN_HVBAT_CELL_V_076Confirmed
- Service 22
DID 1E8B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #77 TAVASCAN_HVBAT_CELL_V_077Confirmed
- Service 22
DID 1E8C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #78 TAVASCAN_HVBAT_CELL_V_078Confirmed
- Service 22
DID 1E8D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #79 TAVASCAN_HVBAT_CELL_V_079Confirmed
- Service 22
DID 1E8E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #80 TAVASCAN_HVBAT_CELL_V_080Confirmed
- Service 22
DID 1E8F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #81 TAVASCAN_HVBAT_CELL_V_081Confirmed
- Service 22
DID 1E90 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #82 TAVASCAN_HVBAT_CELL_V_082Confirmed
- Service 22
DID 1E91 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #83 TAVASCAN_HVBAT_CELL_V_083Confirmed
- Service 22
DID 1E92 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #84 TAVASCAN_HVBAT_CELL_V_084Confirmed
- Service 22
DID 1E93 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #85 TAVASCAN_HVBAT_CELL_V_085Confirmed
- Service 22
DID 1E94 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #86 TAVASCAN_HVBAT_CELL_V_086Confirmed
- Service 22
DID 1E95 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #87 TAVASCAN_HVBAT_CELL_V_087Confirmed
- Service 22
DID 1E96 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #88 TAVASCAN_HVBAT_CELL_V_088Confirmed
- Service 22
DID 1E97 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #89 TAVASCAN_HVBAT_CELL_V_089Confirmed
- Service 22
DID 1E98 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #90 TAVASCAN_HVBAT_CELL_V_090Confirmed
- Service 22
DID 1E99 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #91 TAVASCAN_HVBAT_CELL_V_091Confirmed
- Service 22
DID 1E9A - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #92 TAVASCAN_HVBAT_CELL_V_092Confirmed
- Service 22
DID 1E9B - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #93 TAVASCAN_HVBAT_CELL_V_093Confirmed
- Service 22
DID 1E9C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #94 TAVASCAN_HVBAT_CELL_V_094Confirmed
- Service 22
DID 1E9D - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #95 TAVASCAN_HVBAT_CELL_V_095Confirmed
- Service 22
DID 1E9E - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #96 TAVASCAN_HVBAT_CELL_V_096Confirmed
- Service 22
DID 1E9F - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #97 TAVASCAN_HVBAT_CELL_V_097Confirmed
- Service 22
DID 1EA0 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #98 TAVASCAN_HVBAT_CELL_V_098Confirmed
- Service 22
DID 1EA1 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #99 TAVASCAN_HVBAT_CELL_V_099Confirmed
- Service 22
DID 1EA2 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #100 TAVASCAN_HVBAT_CELL_V_100Confirmed
- Service 22
DID 1EA3 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #101 TAVASCAN_HVBAT_CELL_V_101Confirmed
- Service 22
DID 1EA4 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #102 TAVASCAN_HVBAT_CELL_V_102Confirmed
- Service 22
DID 1EA5 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #103 TAVASCAN_HVBAT_CELL_V_103Confirmed
- Service 22
DID 1EA6 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #104 TAVASCAN_HVBAT_CELL_V_104Confirmed
- Service 22
DID 1EA7 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #105 TAVASCAN_HVBAT_CELL_V_105Confirmed
- Service 22
DID 1EA8 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #106 TAVASCAN_HVBAT_CELL_V_106Confirmed
- Service 22
DID 1EA9 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #107 TAVASCAN_HVBAT_CELL_V_107Confirmed
- Service 22
DID 1EAA - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
HV battery cell voltage, #108 TAVASCAN_HVBAT_CELL_V_108Confirmed
- Service 22
DID 1EAB - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Modules
HV battery module temperature, #5 TAVASCAN_HVBAT_MOD_T_5Confirmed
- Service 22
DID 1EB2 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #6 TAVASCAN_HVBAT_MOD_T_6Confirmed
- Service 22
DID 1EB3 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #7 TAVASCAN_HVBAT_MOD_T_7Confirmed
- Service 22
DID 1EB4 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #8 TAVASCAN_HVBAT_MOD_T_8Confirmed
- Service 22
DID 1EB5 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #9 TAVASCAN_HVBAT_MOD_T_9Confirmed
- Service 22
DID 1EB6 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #10 TAVASCAN_HVBAT_MOD_T_10Confirmed
- Service 22
DID 1EB7 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #11 TAVASCAN_HVBAT_MOD_T_11Confirmed
- Service 22
DID 1EB8 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #12 TAVASCAN_HVBAT_MOD_T_12Confirmed
- Service 22
DID 1EB9 - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #13 TAVASCAN_HVBAT_MOD_T_13Confirmed
- Service 22
DID 1EBA - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #14 TAVASCAN_HVBAT_MOD_T_14Confirmed
- Service 22
DID 1EBB - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #15 TAVASCAN_HVBAT_MOD_T_15Confirmed
- Service 22
DID 1EBC - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
HV battery module temperature, #16 TAVASCAN_HVBAT_MOD_T_16Confirmed
- Service 22
DID 1EBD - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
Climate
A/C compressor power, actual TAVASCAN_AC_COMPRESSOR_PWR_ACTConfirmed
- Service 22
DID 0800 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 W
- Unit
- W
Confirmed for 2025. In testing for 2024, 2026.
A/C refrigerant pressure, sensor 1 TAVASCAN_AC_REFRIG_P_SENS1Confirmed
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 576.708 bar
- Unit
- bar
0x0274 = 628 → = 5.5264 bar
Confirmed for 2025. In testing for 2024, 2026.
A/C refrigerant temperature, sensor 1 TAVASCAN_AC_REFRIG_T_SENS1Confirmed
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x7E9A = 32410 → = 3,201 °C
Confirmed for 2025. In testing for 2024, 2026.
A/C refrigerant temperature, sensor 1 interior TAVASCAN_AC_REFRIG_T_SENS1_INTConfirmed
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x7E9A = 32410 → = 3,201 °C
Confirmed for 2025. In testing for 2024, 2026.
Air pollution level TAVASCAN_AIR_POLUTIONConfirmed
0 means clean air.
- Service 22
DID 26ED - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -12.7 to 12.7
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2025. In testing for 2024, 2026.
CO2 content interior TAVASCAN_CO2_CONTENT_INTERIORConfirmed
- Service 22
DID 42DB - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500
- Unit
- Number
0x04 = 4 → = 400
Confirmed for 2025. In testing for 2024, 2026.
Humidity, inside TAVASCAN_HVAC_INSIDE_HUMConfirmed
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
30 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x7E = 126 → = 63 %
Confirmed for 2025. In testing for 2024, 2026.
Outside humidity TAVASCAN_HVAC_OUTSIDE_HUM
- Service 22
DID 27C3 - Module
746 → 7B0 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2024, 2026. Not supported for 2025.
Outside temperature TAVASCAN_AAT_V2Confirmed
- Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x6B = 107 → = 3.5 °C
Confirmed for 2025. In testing for 2024, 2026.
Radiator fan actual duty TAVASCAN_RAD_FAN_ACT_DUTYConfirmed
- Service 22
DID 2606 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2024, 2026.
Recirculation flap stop, fresh air TAVASCAN_RECIRC_FLAP_STOP_FRESHConfirmed
- Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00AA = 170 → 170
Confirmed for 2025. In testing for 2024, 2026.
Recirculation flap stop, recirculated air TAVASCAN_RECIRC_FLAP_STOP_RECIRCConfirmed
- Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x035F = 863 → 863
Confirmed for 2025. In testing for 2024, 2026.
Recirculation flap, actual TAVASCAN_RECIRC_FLAP_ACT_PCTConfirmed
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x76 = 118 → = 59 %
Confirmed for 2025. In testing for 2024, 2026.
Recirculation flap, actual steps TAVASCAN_RECIRC_FLAP_ACT_STEPSConfirmed
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0243 = 579 → 579
Confirmed for 2025. In testing for 2024, 2026.
Recirculation flap, commanded steps TAVASCAN_RECIRC_FLAP_CMD_STEPSConfirmed
- Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0212 = 530 → 530
Confirmed for 2025. In testing for 2024, 2026.
Refrigerant pressure TAVASCAN_REFRIG_PConfirmed
- Service 22
DID 2605 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 bar
- Unit
- bar
0xFF = 255 → = 51 bar
Confirmed for 2025. In testing for 2024, 2026.
Windshield, temperature TAVASCAN_WNDSHLD_TEMPConfirmed
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
30 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -38.8 to 108.08 °C
- Unit
- °C
0x6A = 106 → = 22.256 °C
Confirmed for 2025. In testing for 2024, 2026.
Control
Brake booster pressure TAVASCAN_BRAKE_BOOSTER_P_V2Confirmed
- Service 22
DID 2005 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
Confirmed for 2025. In testing for 2024, 2026.
Steering wheel angle TAVASCAN_STEER_ANGLE_V2Confirmed
- Service 22
DID 0346 - Module
FC00 → FE0076 - Every
250 ms - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °
- Unit
- °
Confirmed for 2025. In testing for 2024, 2026.
Drivetrain
Motor speed TAVASCAN_MOTOR_RPMConfirmed
- Service 22
DID 3DF8 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
Confirmed for 2025. In testing for 2024, 2026.
Motor torque difference, front to rear TAVASCAN_MOTOR_TRQ_DIFFConfirmed
- Service 22
DID 0343 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 N·m
- Unit
- N·m
Confirmed for 2025. In testing for 2024, 2026.
Motor torque rated, front TAVASCAN_MOTOR_TRQ_RATED_FRONTConfirmed
- Service 22
DID 0344 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 N·m
- Unit
- N·m
Confirmed for 2025. In testing for 2024, 2026.
Motor torque rated, rear TAVASCAN_MOTOR_TRQ_RATED_REAR
- Service 22
DID 0344 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 N·m
- Unit
- N·m
In testing for 2024, 2026. Supported for 2025.
Motor torque, front TAVASCAN_MOTOR_TRQ_FRONTConfirmed
- Service 22
DID 0335 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
Confirmed for 2025. In testing for 2024, 2026.
Motor torque, rear TAVASCAN_MOTOR_TRQ_REARConfirmed
- Service 22
DID 033B - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
Confirmed for 2025. In testing for 2024, 2026.
Torque, calculated from measured currents TAVASCAN_CALC_FROM_MEAS_IS
- Service 22
DID 0308 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000 N·m
- Unit
- N·m
In testing for 2024, 2026. Not supported for 2025.
Engine
A/C compressor load TAVASCAN_CLIMATE_A_C_COMP_LOADConfirmed
- Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 N·m
- Unit
- N·m
0x00 = 0 → = 0 N·m
Confirmed for 2025. In testing for 2024, 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2024.
Coolant circulation pump duty TAVASCAN_COOLANT_CIRC_PUMP_DUTYConfirmed
- Service 22
DID 276D - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Electric motor non-vehicle power limitation TAVASCAN_HV_EM_NV_PWR_LIMITATIONConfirmed
- Service 22
DID 15D1 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 W
- Unit
- W
0xB1 = 177 → = 8,850 W
Confirmed for 2025. In testing for 2024, 2026.
Electric motor power limitation TAVASCAN_HV_EM_PWR_LIMITATIONConfirmed
- Service 22
DID 15D1 - Module
710 → 77A - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276750 W
- Unit
- W
0x0101 = 257 → = 12,850 W
Confirmed for 2025. In testing for 2024, 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2024.
Front left temperature flap actual TAVASCAN_FRONT_LEFT_T_FLAP_ACTConfirmed
- Service 22
DID 2622 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x1C = 28 → = 14 %
Confirmed for 2025. In testing for 2024, 2026.
Front right temperature flap actual TAVASCAN_FRONT_RIGHT_T_FLAP_ACTConfirmed
- Service 22
DID 2626 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x3F = 63 → = 31.5 %
Confirmed for 2025. In testing for 2024, 2026.
Outside temperature, from cabin sensor TAVASCAN_AAT_CABINConfirmed
- Service 22
DID 260A - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x6A = 106 → = 3 °C
Confirmed for 2025. In testing for 2024, 2026.
Radiator fan commanded duty TAVASCAN_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2024, 2026.
Radiator fan duty TAVASCAN_RADIATOR_FAN_DUTYConfirmed
- Service 22
DID 2055 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Temperature, evaporator output TAVASCAN_HVAC_EVAP_TConfirmed
- Service 22
DID 2612 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0190 = 400 → = 40 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, front left deflector TAVASCAN_FRONT_LEFT_DEFL_TConfirmed
- Service 22
DID 260C - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x6C = 108 → = 35.964 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, front right deflector TAVASCAN_FRONT_RIGHT_DEFL_TConfirmed
- Service 22
DID 260D - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x62 = 98 → = 32.634 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, interior TAVASCAN_HVAC_IATConfirmed
- Service 22
DID 2613 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x00F1 = 241 → = 24.1 °C
Confirmed for 2025. In testing for 2024, 2026.
Temperature, rear deflector TAVASCAN_REAR_DEFL_TConfirmed
- Service 22
DID 263D - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x72 = 114 → = 37.962 °C
Confirmed for 2025. In testing for 2024, 2026.
GPS
Satellites, tracked TAVASCAN_GPS_SATS_TRACKEDConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x10 = 16 → 16
Confirmed for 2025. In testing for 2024, 2026.
Satellites, visible TAVASCAN_GPS_SATS_VISIBLEConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2025. In testing for 2024, 2026.
Movement
A/C compressor, speed TAVASCAN_A_C_CMPR_SPEEDConfirmed
- Service 22
DID 2603 - Module
746 → 7B0 - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2025. In testing for 2024, 2026.
Acceleration TAVASCAN_ACCEL_V3Confirmed
- Service 22
DID 4539 - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
Confirmed for 2025. In testing for 2024, 2026.
Motor RPM TAVASCAN_ELDRIVE_MOTOR_RPMConfirmed
- Service 22
DID F40C - Module
FC00 → FE007B - Every
1 s - Testing for 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2025. In testing for 2024, 2026.
Vehicle speed TAVASCAN_VSS_V2Confirmed
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
FC00 → FE007B - Every
250 ms - Testing for 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2025. In testing for 2024, 2026.
Stats
Crashes, driver side TAVASCAN_CRASH_DRVRConfirmed
- Service 22
DID 2354 - Module
715 → 77F - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2024, 2026.
Crashes, front TAVASCAN_CRASH_FRONTConfirmed
- Service 22
DID 2353 - Module
715 → 77F - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2024, 2026.
Crashes, passenger side TAVASCAN_CRASH_PASSConfirmed
- Service 22
DID 2355 - Module
715 → 77F - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2024, 2026.
Crashes, rear TAVASCAN_CRASH_REARConfirmed
- Service 22
DID 2356 - Module
715 → 77F - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2024, 2026.
Rollovers TAVASCAN_ROLLOVERConfirmed
- Service 22
DID 2357 - Module
715 → 77F - Every
1 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2025. In testing for 2024, 2026.
Trips
Average consumption, category 0 TAVASCAN_AVG_CSMP_CAT0Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x008E = 142 → = 14.2 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 1 TAVASCAN_AVG_CSMP_CAT1Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x0088 = 136 → = 13.6 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 2 TAVASCAN_AVG_CSMP_CAT2Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x0080 = 128 → = 12.8 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 3 TAVASCAN_AVG_CSMP_CAT3Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x009A = 154 → = 15.4 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 4 TAVASCAN_AVG_CSMP_CAT4Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x009F = 159 → = 15.9 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 5 TAVASCAN_AVG_CSMP_CAT5Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2025. In testing for 2024, 2026.
Average consumption, category 6 TAVASCAN_AVG_CSMP_CAT6Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x0000 = 0 → = 0 kWh
Confirmed for 2025. In testing for 2024, 2026.
Odometer TAVASCAN_ENG_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
FC00 → FE0076 - Every
1 s - Testing for 2024, 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
Confirmed for 2025. In testing for 2024, 2026.
Odometer, BMS TAVASCAN_BMS_ODO
- Service 22
DID 02BD - Module
FC00 → FE007B - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2024, 2026. Not supported for 2025.
Range remaining, displayed TAVASCAN_RANGEConfirmed
Pelican can show this parameter as the electric range.
- Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing for 2024, 2026
Example reply from a 2025 Cupra Tavascan.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mi
- Unit
- mi
0x00A6 = 166 → 166 mi
Confirmed for 2025. In testing for 2024, 2026.