FIAT Panda

Parameters

The FIAT Panda has 132 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery state of charge PANDA_BAT_ST_CHG

  • Service 22DID 19BD
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery state of charge PANDA_BAT_ST_CHG

  • Service 22DID 19BD
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2026.

Battery voltage PANDA_BATT_V_ECU

  • Service 22DID 1955
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 20 V
Unit
V

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Battery voltage, BCM PANDA_BATT_V_BCMConfirmed

  • Service 22DID 1004
  • ModuleDA40 → 40
  • Every30 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. Supported for 2016, 2018.

Control

Steering wheel angle PANDA_STEER_ANGLEConfirmed

  • Service 22DID 0885
  • ModuleDA30 → 30
  • Every100 ms
  • Testing for 1996 to 2013, 2015 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

Confirmed for 2014, 2023. In testing for 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2016, 2018, 2023.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023. Supported for 2014, 2016, 2018.

Distance with water in fuel warning PANDA_WATER_FUEL_DISTConfirmed

  • Service 22DID 1009
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. Supported for 2014, 2016, 2018.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2023. Supported for 2014, 2016, 2018.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. Supported for 2016, 2018.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2014, 2016, 2018.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023. Supported for 2014, 2016, 2018.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2014, 2016, 2018.

Emissions

Catalyst inlet temperature PANDA_CATALYST_INLET_T

  • Service 22DID 3914
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Distance between particulate filter regeneration runs, average of the last 5 PANDA_AVG_DIST_REGENS

  • Service 22DID 3809
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 10000 km
Unit
km

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Distance since last DPF regen PANDA_DIST_SINCE_REGEN

  • Service 22DID 3807
  • ModuleDA10 → 10
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 10000 km
Unit
km

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Forced regen state PANDA_FORCED_REGEN

  • Service 22DID 18EC
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Lambda downstream DPF O2 concentration PANDA_LAMBDA_DPF_DSConfirmed

  • Service 22DID 18ED
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 25 %
Unit
%

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Particulate filter differential pressure PANDA_DPF_DIFF_PRESS

  • Service 22DID 18E2
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
-50 to 50 kPa
Unit
kPa

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter flow resistance PANDA_DPF_FLOW_RES

  • Service 22DID 18E8
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter inlet temperature PANDA_DPF_INLET_T

  • Service 22DID 18DE
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter outlet temperature PANDA_DPF_OUTLET_T

  • Service 22DID 3915
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regen duration, average of the last 5 PANDA_AVG_REGEN_DUR

  • Service 22DID 380A
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val60
Range
0 to 30 min
Unit
min

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regen interrupted count PANDA_REGEN_INTERRUPTED

  • Service 22DID 18A5
  • ModuleDA10 → 10
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regen progress PANDA_REGEN_PROGRESS

  • Service 22DID 380B
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regen temperature, average of the last 5 PANDA_AVG_REGEN_TEMP

  • Service 22DID 3808
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−40
Range
-40 to 900 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regeneration interruptions, consecutive PANDA_REGEN_CONSEC_INTERRUPTEDConfirmed

  • Service 22DID 18AE
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Particulate filter soot clogging level PANDA_DPF_SOOT_PCT

  • Service 22DID 18E4
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2023. Supported for 2016, 2018.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2023.

Air conditioning pressure PANDA_AC_P

  • Service 22DID 192F
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350
Unit
Raw value

In testing for 1996 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2014, 2016, 2018.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2023. Supported for 2016, 2018.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023. Supported for 2016, 2018.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023. Supported for 2016, 2018.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2016, 2018.

Coolant temperature PANDA_ECT_ECUConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 1003
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2023. Supported for 2016, 2018.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2023.

Engine oil degradation PANDA_OIL_DEGRAD

  • Service 22DID 3813
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023.

Engine operational status PANDA_ENGINE_STATUSConfirmed

  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2023.

Engine RPM PANDA_RPMConfirmed

  • Service 22DID 1000
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023. Supported for 2014, 2016, 2018.

Exhaust gas recirculation cooler downstream temperature PANDA_EGR_COOLER_T

  • Service 22DID 3917
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel correction cylinder 1 PANDA_FUEL_CORR_CYL1

  • Service 22DID 3800
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel correction cylinder 2 PANDA_FUEL_CORR_CYL2

  • Service 22DID 3801
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel correction cylinder 3 PANDA_FUEL_CORR_CYL3

  • Service 22DID 3802
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel correction cylinder 4 PANDA_FUEL_CORR_CYL4

  • Service 22DID 3803
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel rail pressure commanded PANDA_RAIL_PRESS_CMD

  • Service 22DID 1946
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3000 bar
Unit
bar

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Fuel rail pressure measured PANDA_RAIL_PRESS

  • Service 22DID 1947
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3000 bar
Unit
bar

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2014, 2016, 2018.

Intake air temperature after the intercooler PANDA_IAT_TURBOConfirmed

  • Service 22DID 1935
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2014, 2016, 2018.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023. Supported for 2016, 2018.

M-Prop injection command PANDA_MPROP_CMD

  • Service 22DID 18D0
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Mass airflow sensor temperature PANDA_MAF_TEMP

  • Service 22DID 193F
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regeneration completions, total PANDA_REGEN_SUCCESSFULY

  • Service 22DID 3912
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Particulate filter regeneration starts, total PANDA_REGEN_STARTED_TOT

  • Service 22DID 18A4
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023. Supported for 2016, 2018.

Swirl actuator command PANDA_SWIRL_CMD

  • Service 22DID 189B
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-100 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2023. Supported for 2016, 2018.

Turbo boost actuator duty PANDA_TURBO_BOOST_ACTUATOR

  • Service 22DID 193A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781310000
Range
-100 to 99.22 %
Unit
%

In testing for 1996 to 2026.

Turbo boost ADC PANDA_TURBO_BOOST_ADC

  • Service 22DID 195B
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mV
Unit
mV

In testing for 1996 to 2026.

Turbo boost pressure PANDA_BOOST

  • Service 22DID 195A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
-100 to 300 kPa
Unit
kPa

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Turbo boost, commanded PANDA_TURBO_BOOST_CMD

  • Service 22DID 1959
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2026.

Variable geometry turbo position actual PANDA_VGT_ACTConfirmed

  • Service 22DID 18A0
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Variable geometry turbo position commanded PANDA_VGT_CMD

  • Service 22DID 189F
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Variable oil pump position PANDA_OIL_PUMP

  • Service 22DID 194F
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Internal

Boost bressure A control status BP_ASAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2023.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2016, 2018.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023.

Fuel

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2023.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2023.

Fuel ramp pressure ADC PANDA_FUEL_RAMP_P_ADC

  • Service 22DID 1948
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mV
Unit
mV

In testing for 1996 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2016, 2018, 2023.

Fuel temperature PANDA_FUEL_T

  • Service 22DID 1900
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50−40
Range
-695 to 615 °C
Unit
°C

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2023.

Movement

Front left wheel speed PANDA_FL_VSS

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 km/h
Unit
km/h

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Front right wheel speed PANDA_FR_VSS

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 km/h
Unit
km/h

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Max RPM reached PANDA_MAX_RPM_REACHED

  • Service 22DID 2005
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×40
Range
-5120 to 5080 °C
Unit
°C

In testing for 1996 to 2026.

Rear left wheel speed PANDA_RL_VSS

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 km/h
Unit
km/h

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Rear right wheel speed PANDA_RR_VSS

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 km/h
Unit
km/h

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2014, 2016, 2018, 2023.

Vehicle speed, engine module PANDA_VSS_ECU

Pelican can show this parameter as the speed.

  • Service 22DID 190B
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2023. Supported for 2014, 2016, 2018.

Orientation

Lateral acceleration PANDA_LAT_G

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 4 to 15 of the reply, 12 bits.

Formula
val50−40.96
Range
-40.94 to 40.94 m/s²
Unit
m/s²

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Longitudinal acceleration PANDA_LNG_G

  • Service 22DID 2962
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 20 to 31 of the reply, 12 bits.

Formula
val50−40.96
Range
-40.94 to 40.94 m/s²
Unit
m/s²

In testing for 1996 to 2005, 2007 to 2013, 2015 to 2017, 2019 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2018, 2023.

Transmission

Gear engaged PANDA_GEAR_ECUConfirmed

  • Service 22DID 192D
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1996 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.

Transmission oil temperature PANDA_TOT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 18
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-512 to 512 °F
Unit
°F

In testing for 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.

Trips

Odometer PANDA_ODO_DA10

  • Service 22DID 2001
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 1996 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.