Parameters
The Honda Civic has 358 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2007 to 2026.
Distance traveled since last charge CIVIC_BAT_DISTConfirmed
- Service 22
DID 2240 - Module
DA0E → 0E - Every
1 s - Testing for 2014 to 2026
Bits 80 to 111 of the reply, 32 bits.
- Formula
- Range
- 0 to 250000 km
- Unit
- km
Confirmed for 2012 to 2013. In testing for 2014.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 13 to 14 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
3 | Not PSA |
Confirmed for 2022 to 2023, 2025 to 2026.
High voltage battery cells, max state of charge CIVIC_CELL_MAX_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery cells, max state of charge CIVIC_CELL_MIN_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery module 1A temperature CIVIC_HVB_MOD_1A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery module 3A temperature CIVIC_HVB_MOD_3A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery total capacity CIVIC_HVB_CAPConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery total current CIVIC_HVB_C_TOTALConfirmed
Pelican can show this parameter as the traction battery current.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 200 A
- Unit
- A
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery voltage CIVIC_HVB_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020, 2022 to 2023, 2025 to 2026. Supported for 2013, 2024.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2022 to 2023, 2025 to 2026.
State of charge CIVIC_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Cells
Individual cell voltage A1 CIVIC_CEL_V_A1Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A2 CIVIC_CEL_V_A2Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A3 CIVIC_CEL_V_A3Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A4 CIVIC_CEL_V_A4Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A5 CIVIC_CEL_V_A5Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A6 CIVIC_CEL_V_A6Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A7 CIVIC_CEL_V_A7Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A8 CIVIC_CEL_V_A8Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A9 CIVIC_CEL_V_A9Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A10 CIVIC_CEL_V_A10Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A11 CIVIC_CEL_V_A11Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A12 CIVIC_CEL_V_A12Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A13 CIVIC_CEL_V_A13Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A14 CIVIC_CEL_V_A14Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A15 CIVIC_CEL_V_A15Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A16 CIVIC_CEL_V_A16Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A17 CIVIC_CEL_V_A17Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A18 CIVIC_CEL_V_A18Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A19 CIVIC_CEL_V_A19Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A20 CIVIC_CEL_V_A20Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A21 CIVIC_CEL_V_A21Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A22 CIVIC_CEL_V_A22Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A23 CIVIC_CEL_V_A23Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A24 CIVIC_CEL_V_A24Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A25 CIVIC_CEL_V_A25Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A26 CIVIC_CEL_V_A26Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A27 CIVIC_CEL_V_A27Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A28 CIVIC_CEL_V_A28Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A29 CIVIC_CEL_V_A29Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A30 CIVIC_CEL_V_A30Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A31 CIVIC_CEL_V_A31Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A32 CIVIC_CEL_V_A32Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A33 CIVIC_CEL_V_A33Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A34 CIVIC_CEL_V_A34Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A35 CIVIC_CEL_V_A35Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A36 CIVIC_CEL_V_A36Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A37 CIVIC_CEL_V_A37Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A38 CIVIC_CEL_V_A38Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A39 CIVIC_CEL_V_A39Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A40 CIVIC_CEL_V_A40Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A41 CIVIC_CEL_V_A41Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A42 CIVIC_CEL_V_A42Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A43 CIVIC_CEL_V_A43Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A44 CIVIC_CEL_V_A44Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A45 CIVIC_CEL_V_A45Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A46 CIVIC_CEL_V_A46Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A47 CIVIC_CEL_V_A47Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A48 CIVIC_CEL_V_A48Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A49 CIVIC_CEL_V_A49Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A50 CIVIC_CEL_V_A50Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A51 CIVIC_CEL_V_A51Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A52 CIVIC_CEL_V_A52Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A53 CIVIC_CEL_V_A53Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A54 CIVIC_CEL_V_A54Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A55 CIVIC_CEL_V_A55Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A56 CIVIC_CEL_V_A56Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A57 CIVIC_CEL_V_A57Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A58 CIVIC_CEL_V_A58Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A59 CIVIC_CEL_V_A59Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A60 CIVIC_CEL_V_A60Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A61 CIVIC_CEL_V_A61Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A62 CIVIC_CEL_V_A62Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A63 CIVIC_CEL_V_A63Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A64 CIVIC_CEL_V_A64Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A65 CIVIC_CEL_V_A65Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A66 CIVIC_CEL_V_A66Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A67 CIVIC_CEL_V_A67Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A68 CIVIC_CEL_V_A68Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A69 CIVIC_CEL_V_A69Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A70 CIVIC_CEL_V_A70Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A71 CIVIC_CEL_V_A71Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A72 CIVIC_CEL_V_A72Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A73 CIVIC_CEL_V_A73Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A74 CIVIC_CEL_V_A74Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A75 CIVIC_CEL_V_A75Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A76 CIVIC_CEL_V_A76Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A77 CIVIC_CEL_V_A77Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A78 CIVIC_CEL_V_A78Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A79 CIVIC_CEL_V_A79Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A80 CIVIC_CEL_V_A80Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A81 CIVIC_CEL_V_A81Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A82 CIVIC_CEL_V_A82Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A83 CIVIC_CEL_V_A83Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A84 CIVIC_CEL_V_A84Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Climate
A/C pressure CIVIC_AC_PConfirmed
- Service 22
DID 2613 - Module
DA0E → 0E - Every
1 s - Testing for 1996 to 2011, 2014, 2016 to 2017, 2019 to 2026
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 4000 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2015. In testing for 1996, 1999 to 2004, 2006, 2014. Supported for 2018. Not supported for 1997 to 1998, 2005, 2007 to 2011, 2016 to 2017, 2019 to 2026.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. Supported for 2021, 2023, 2025.
Outside air temperature CIVIC_AATConfirmed
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing for 1996 to 2015
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
Confirmed for 2016 to 2026. Not supported for 2015.
Clocks
Time since engine start CIVIC_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2015 to 2026.
Time since engine start CIVIC_RUNTM_V2Confirmed
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA11 → 11 - Every
5 s - Testing for 1996 to 2006, 2012 to 2026
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2007 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2012 to 2014.
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2008, 2011 to 2013, 2015 to 2018, 2020, 2022 to 2026. Supported for 2007, 2009 to 2010, 2014, 2019, 2021.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2008, 2010 to 2020, 2022 to 2026. Supported for 2009, 2021.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007, 2010 to 2020, 2022 to 2026. Supported for 2008 to 2009, 2021.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2010 to 2015. Supported for 2007 to 2009, 2016 to 2019, 2021 to 2023, 2025.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2009 to 2015, 2017 to 2020, 2022 to 2026. Supported for 2007 to 2008, 2016, 2021.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2009 to 2015, 2017 to 2020, 2022 to 2026. Supported for 2007 to 2008, 2016, 2021.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2007 to 2026.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2007 to 2026.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007 to 2026.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2007 to 2026.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2007, 2009, 2011 to 2013, 2015 to 2026. Supported for 2008, 2010, 2014.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2007 to 2026.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2007 to 2026.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009 to 2011, 2013, 2016 to 2018, 2020, 2022 to 2026. Supported for 2007 to 2008, 2012, 2014 to 2015, 2019, 2021.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2007 to 2026.
ECU
Variable valve control CIVIC_VTEC_CTRLConfirmed
- Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 1996 to 2014, 2021
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2015 to 2020, 2022 to 2026. In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013.
Electrical
Brake fluid pressure CIVIC_BRK_FLD_PConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 2024
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Raw value
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Brake pedal stroke CIVIC_BRK_PED_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 2024
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 mm
- Unit
- mm
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Brake pressure CIVIC_BRK_PConfirmed
- Service 22
DID 4005 - Module
DA28 → 28 - Every
1 s
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2016 to 2026.
Brake switch CIVIC_BRK_SWConfirmed
- Service 22
DID 4004 - Module
DA28 → 28 - Every
1 s
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2016 to 2026.
Master cylinder stroke CIVIC_MSTR_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 2024
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Slave cylinder stroke CIVIC_SLV_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing for 2024
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 mm
- Unit
- mm
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Engine
A/C clutch CIVIC_AC_CLUTCHConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed
Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 53 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2008, 2010, 2012 to 2018, 2020, 2022 to 2026. Supported for 2007, 2009, 2011, 2019, 2021.
Active cylinders CIVIC_ACTIVE_CYLConfirmed
- Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing for 2026
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
Confirmed for 2015 to 2025. Not supported for 2026.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2020, 2022, 2024 to 2026. Supported for 2019, 2021, 2023.
Air conditioner clutch CIVIC_AC_CLUConfirmed
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2007 to 2016, 2019. Supported for 2017 to 2018, 2021 to 2023, 2025.
Air/gas ratio CIVIC_AIRGAS_RATIOConfirmed
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2015 to 2026.
Air/gas ratio CIVIC_AIRGAS_RATIO_V2Confirmed
- Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing for 1996 to 2006, 2012 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2007 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2012 to 2014.
Ambient air temperature, cabin CIVIC_AAT_CABConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Ambient air temperature, outside CIVIC_AAT_OUTConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2009 to 2010, 2012 to 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2011, 2016, 2019, 2021, 2023.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2026.
Catalyst temperature CIVIC_CAT_TConfirmed
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 1996 to 2006, 2012 to 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
Confirmed for 2007 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2012 to 2014.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2009, 2012 to 2014, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2011, 2015 to 2016, 2019, 2021, 2023.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2008, 2010, 2012 to 2014, 2022, 2025 to 2026. Supported for 2007, 2009, 2011, 2015 to 2016, 2018, 2020, 2023 to 2024.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2007 to 2026.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012, 2014 to 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2011, 2013, 2016, 2019, 2021, 2023.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012, 2014 to 2015. Supported for 2007 to 2011, 2013, 2016, 2018 to 2019, 2021, 2023, 2025.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2008, 2012, 2014, 2022, 2025 to 2026. Supported for 2007, 2009 to 2011, 2013, 2015 to 2016, 2018, 2020, 2023 to 2024.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2007 to 2016, 2019, 2022 to 2026. Supported for 2017 to 2018, 2020.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Engine coolant temperature sensor 1 CIVIC_ECT_1Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Engine coolant temperature sensor 2 CIVIC_ECT_2Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Engine coolant temperature sensor 3 CIVIC_ECT_3Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Engine coolant temperature sensor 4 CIVIC_ECT_4Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2020, 2022, 2024 to 2026. Supported for 2021, 2023.
Engine oil temperature, variant 3 CIVIC_EOT_VAR_3Confirmed
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing for 1996 to 2014, 2016 to 2026
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013, 2016 to 2020, 2022 to 2026.
Engine oil temperature, variant 4 CIVIC_EOT_VAR_4Confirmed
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing for 1996 to 2014, 2016 to 2026
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013, 2016 to 2020, 2022 to 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2020, 2022, 2024 to 2026. Supported for 2019, 2021, 2023.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2008, 2010, 2012 to 2018, 2020, 2022 to 2026. Supported for 2007, 2009, 2011, 2019, 2021.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2012, 2014, 2017 to 2018, 2020. Supported for 2007 to 2011, 2013, 2015 to 2016, 2019, 2021.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2008, 2014 to 2015, 2017, 2022, 2024 to 2026. Supported for 2010, 2012 to 2013, 2016, 2018 to 2021, 2023.
Fuel/air commanded equivalence ratio CIVIC_FUELAIR_CARConfirmed
- Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Generator CIVIC_GENConfirmed
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Generator CIVIC_GENERATORConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2008, 2010 to 2012, 2014. Supported for 2007, 2009, 2013, 2015 to 2019, 2022.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015, 2017, 2022, 2024 to 2026. Supported for 2016, 2018 to 2021, 2023.
Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. Supported for 2016 to 2026.
Intake air temperature, bank 2, sensor 1 IAT_21SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. Supported for 2016 to 2026.
Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. Supported for 2016 to 2026.
Intake air temperature, bank 2, sensor 3 IAT_23SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015. Supported for 2016 to 2026.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2008, 2010 to 2012, 2014 to 2015, 2018, 2020, 2022, 2024 to 2026. Supported for 2007, 2009, 2013, 2016 to 2017, 2019, 2021, 2023.
Knock control CIVIC_KNOCK_CONTROLConfirmed
ECU's determination of fuel quality.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Raw value
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Knock control CIVIC_KNOCK_CONTROL_V2Confirmed
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 1996 to 2006, 2012 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2007 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2012 to 2014.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2009 to 2010, 2012, 2014 to 2015, 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2011, 2013, 2016 to 2017, 2019, 2021, 2023.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2015, 2018, 2020, 2022, 2024 to 2026. Supported for 2016 to 2017, 2019, 2021, 2023.
Maintenance, air cleaner CIVIC_MAINT_AIR_CLNConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, cabin filter CIVIC_MAINT_CABIN_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, engine coolant CIVIC_MAINT_COOLConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, general inspection CIVIC_MAINT_INSPConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, oil & filter CIVIC_MAINT_OIL_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, rake fluid CIVIC_MAINT_BRK_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, spark plugs & valves CIVIC_MAINT_SPARKConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Maintenance, transmission fluid CIVIC_MAINT_TRANS_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2016 to 2020, 2022 to 2026. Supported for 2021.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2016 to 2020, 2022 to 2026. Supported for 2021.
Misfire count #1 CIVIC_MIS_1Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Misfire count #2 CIVIC_MIS_2Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Misfire count #3 CIVIC_MIS_3Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Misfire count #4 CIVIC_MIS_4Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
Misfire count 1 CIVIC_MIS_CNT_1
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 1,, variant 1 CIVIC_MIS_CNT_1_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 1,, variant 2 CIVIC_MIS_CNT_1_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 1,, variant 3 CIVIC_MIS_CNT_1_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 2 CIVIC_MIS_CNT_2
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 2,, variant 1 CIVIC_MIS_CNT_2_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 2,, variant 2 CIVIC_MIS_CNT_2_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 2,, variant 3 CIVIC_MIS_CNT_2_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 3 CIVIC_MIS_CNT_3
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 3,, variant 1 CIVIC_MIS_CNT_3_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 3,, variant 2 CIVIC_MIS_CNT_3_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 3,, variant 3 CIVIC_MIS_CNT_3_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 4 CIVIC_MIS_CNT_4
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 4,, variant 1 CIVIC_MIS_CNT_4_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 4,, variant 2 CIVIC_MIS_CNT_4_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 4,, variant 3 CIVIC_MIS_CNT_4_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 5,, variant 1 CIVIC_MIS_CNT_5_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 5,, variant 2 CIVIC_MIS_CNT_5_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 5,, variant 3 CIVIC_MIS_CNT_5_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 6,, variant 1 CIVIC_MIS_CNT_6_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011. Not supported for 2005, 2008, 2010.
Misfire count 6,, variant 2 CIVIC_MIS_CNT_6_VAR_2Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Misfire count 6,, variant 3 CIVIC_MIS_CNT_6_VAR_3Confirmed
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2009 to 2026
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2007 to 2008. In testing for 1996 to 2004, 2006, 2009, 2011. Not supported for 2005, 2010.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2007 to 2026.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018, 2020, 2022, 2024 to 2026. Supported for 2016 to 2017, 2019, 2021, 2023.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2012 to 2015, 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2011, 2016 to 2017, 2019, 2021, 2023.
Transmission fluid temperature, variant 4 CIVIC_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013, 2015 to 2020, 2022 to 2026.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2014, 2018, 2020, 2022, 2024 to 2026. Supported for 2013, 2015 to 2017, 2019, 2021, 2023.
Variable timing control duty CIVIC_VARIABLE_TIM_CTRLConfirmed
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 1996 to 2006, 2012 to 2026
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2012 to 2014.
Variable timing control duty CIVIC_VTC_DUTYConfirmed
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1996 to 2006, 2008 to 2009, 2011, 2013 to 2014
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007, 2010, 2012, 2015 to 2026. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2009, 2011, 2013 to 2014.
VTEC valve control CIVIC_VTEC_VALVE_CTRLConfirmed
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing for 1996 to 2006, 2026
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007 to 2011. In testing for 1996 to 2003, 2006. Supported for 2022 to 2025. Not supported for 2004 to 2005, 2026.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
Internal
Boost bressure A control status BP_ASAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 78 to 79 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | BP_A_OL | Open loop |
2 | BP_A_CL | Closed loop |
3 | BP_A_FAULT | Fault |
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2016, 2018 to 2019, 2022, 2025.
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2015, 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026. Supported for 2021.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026. Supported for 2021.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017. Supported for 2012, 2016, 2018 to 2025.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2012, 2016, 2018 to 2025.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2017. Supported for 2012, 2016, 2018 to 2025.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2017. Supported for 2012, 2016, 2018 to 2025.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018, 2020, 2022, 2024 to 2026. Supported for 2016, 2019, 2021, 2023.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024. Supported for 2021 to 2023, 2025.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009, 2013, 2015 to 2018, 2020, 2022, 2024 to 2026. Supported for 2007 to 2008, 2010 to 2012, 2014, 2019, 2021, 2023.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2007 to 2013, 2015, 2021, 2023, 2025 to 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2016 to 2020, 2022 to 2025. Supported for 2012, 2021.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2016 to 2018, 2020, 2022, 2025 to 2026. Supported for 2007 to 2015, 2019, 2021, 2023 to 2024.
SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2016 to 2018, 2020, 2025. Supported for 2007 to 2015, 2019, 2021 to 2024, 2026.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2007 to 2013, 2015, 2021, 2023, 2025 to 2026.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2016 to 2020, 2022 to 2025. Supported for 2012, 2021.
Fuel
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2020, 2022 to 2026. Supported for 2021.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2021, 2023.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020, 2022 to 2026. Supported for 2021.
Fuel level CIVIC_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
5 s - Testing for 1996 to 2015
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2016 to 2026. Not supported for 2015.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007, 2009 to 2020, 2022 to 2026. Supported for 2008, 2021.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007, 2009 to 2020, 2022 to 2026. Supported for 2008, 2021.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2020, 2022 to 2026. Supported for 2021.
Fuel/air commanded equivalence ratio CIVIC_FUEL_AIR_RATIO
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Supported for 2015 to 2026.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020, 2022 to 2026. Supported for 2021.
Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2020, 2022 to 2026.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2007 to 2026.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2007 to 2020, 2022 to 2026. Supported for 2021.
Tires
Maintenance, tire rotation CIVIC_MAINT_TIREConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2018 to 2020, 2022, 2024 to 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2016 to 2017, 2021, 2023. Not supported for 2018 to 2020, 2022, 2024 to 2026.
Transmission
Automatic transmission fluid temperature CIVIC_ATF_TConfirmed
- Service 22
DID 2201 - Module
DA1D → 1D - Every
1 s - Testing for 1996 to 2007, 2012 to 2026
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2008 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2007, 2012 to 2014.
Current gear CIVIC_GEAR_1DConfirmed
- Service 22
DID 2221 - Module
DA1D → 1D - Every
1 s - Testing for 1996 to 2007, 2012 to 2026
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2008 to 2011. In testing for 1996, 1999 to 2003, 2006. Not supported for 1997 to 1998, 2004 to 2005, 2007, 2012 to 2014.
Current gear, variant 2 CIVIC_CURRENT_GEAR_VAR_2Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing for 1996 to 2011, 2014 to 2022, 2024 to 2026
Bits 352 to 359 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2012 to 2013. In testing for 1996 to 2004, 2006 to 2007, 2011, 2014, 2021. Supported for 2023. Not supported for 2005, 2008 to 2010, 2015 to 2020, 2022, 2024 to 2026.
Current gear, variant 3 CIVIC_CURRENT_GEAR_VAR_3Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing for 1996 to 2011, 2014 to 2022, 2024 to 2026
Bits 368 to 375 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2012 to 2013. In testing for 1996 to 2004, 2006 to 2007, 2011, 2014, 2021. Supported for 2023. Not supported for 2005, 2008 to 2010, 2015 to 2020, 2022, 2024 to 2026.
Transmission fluid temperature CIVIC_ATF_T_DA1E
- Service 22
DID 3083 - Module
DA1E → 1E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013, 2015 to 2020, 2022 to 2026.
Transmission gear CIVIC_GEAR
- Service 22
DID 3086 - Module
DA1E → 1E - Every
250 ms - Testing
Bits 160 to 167 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | P | Park |
1 | D1 | Drive 1 |
2 | D2 | Drive 2 |
3 | D3 | Drive 3 |
4 | D4 | Drive 4 |
5 | D5 | Drive 5 |
6 | D6 | Drive 6 |
7 | D7 | Drive 7 |
8 | D8 | Drive 8 |
9 | D9 | Drive 9 |
14 | N | Neutral |
15 | R | Reverse |
In testing for 1996 to 2004, 2006 to 2007, 2009, 2011, 2014, 2021. Not supported for 2005, 2008, 2010, 2012 to 2013, 2015 to 2020, 2022 to 2026.
Trips
Odometer CIVIC_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2015 to 2026.
Odometer CIVIC_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA1D → 1D - Every
5 s - Testing for 1996 to 2006, 2008 to 2026
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1996, 1999 to 2003, 2006. Supported for 2007. Not supported for 1997 to 1998, 2004 to 2005, 2008 to 2014.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2020, 2022 to 2026. Supported for 2021.
Odometer, variation 3 CIVIC_ODO_V3Confirmed
- Service 22
DID 7022 - Module
DA60 → 60 - Every
1 s
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
Confirmed for 2016 to 2026.