Honda Fit

Parameters

The Honda Fit has 294 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage VPWRConfirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2008 to 2010, 2013, 2018, 2020, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2008 to 2010, 2013, 2018, 2020, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

Distance traveled since last charge FIT_BAT_DISTConfirmed

  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2006, 2009 to 2021, 2023 to 2026

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

Confirmed for 2007 to 2008, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2009 to 2011, 2013, 2018 to 2019.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode
3Not PSA

Confirmed for 2020, 2022.

High voltage battery cells, max state of charge FIT_CELL_MAX_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery cells, max state of charge FIT_CELL_MIN_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery module 1A temperature FIT_HVB_MOD_1A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery module 3A temperature FIT_HVB_MOD_3A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery total current FIT_HVB_C_TOTALConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-100 to 200 A
Unit
A

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery voltage FIT_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2020, 2022.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.98 V
Unit
V

Confirmed for 2020, 2022.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2020, 2022.

State of charge FIT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Cells

Individual cell voltage A1 FIT_CEL_V_A1Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A2 FIT_CEL_V_A2Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A3 FIT_CEL_V_A3Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A4 FIT_CEL_V_A4Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A5 FIT_CEL_V_A5Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A6 FIT_CEL_V_A6Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A7 FIT_CEL_V_A7Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A8 FIT_CEL_V_A8Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A9 FIT_CEL_V_A9Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A10 FIT_CEL_V_A10Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A11 FIT_CEL_V_A11Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A12 FIT_CEL_V_A12Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A13 FIT_CEL_V_A13Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A14 FIT_CEL_V_A14Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A15 FIT_CEL_V_A15Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A16 FIT_CEL_V_A16Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A17 FIT_CEL_V_A17Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A18 FIT_CEL_V_A18Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A19 FIT_CEL_V_A19Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A20 FIT_CEL_V_A20Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A21 FIT_CEL_V_A21Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A22 FIT_CEL_V_A22Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A23 FIT_CEL_V_A23Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A24 FIT_CEL_V_A24Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A25 FIT_CEL_V_A25Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A26 FIT_CEL_V_A26Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A27 FIT_CEL_V_A27Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A28 FIT_CEL_V_A28Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A29 FIT_CEL_V_A29Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A30 FIT_CEL_V_A30Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A31 FIT_CEL_V_A31Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A32 FIT_CEL_V_A32Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A33 FIT_CEL_V_A33Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A34 FIT_CEL_V_A34Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A35 FIT_CEL_V_A35Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A36 FIT_CEL_V_A36Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A37 FIT_CEL_V_A37Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A38 FIT_CEL_V_A38Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A39 FIT_CEL_V_A39Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A40 FIT_CEL_V_A40Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A41 FIT_CEL_V_A41Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A42 FIT_CEL_V_A42Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A43 FIT_CEL_V_A43Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A44 FIT_CEL_V_A44Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A45 FIT_CEL_V_A45Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A46 FIT_CEL_V_A46Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A47 FIT_CEL_V_A47Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A48 FIT_CEL_V_A48Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Climate

A/C pressure FIT_AC_PConfirmed

  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2006, 2009 to 2017, 2020 to 2021, 2023 to 2026

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 4000 kPa
Unit
kPa

Confirmed for 2007 to 2008, 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2009 to 2011, 2013.

Outside air temperature FIT_AATConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 2001 to 2017

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °F
Unit
°F

Confirmed for 2018 to 2019. In testing for 2001 to 2006, 2012, 2014 to 2017. Not supported for 2007 to 2011, 2013.

Outside air temperature FIT_AAT_CConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 2021, 2023 to 2026

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °C
Unit
°C

Confirmed for 2022. In testing for 2021, 2023 to 2026. Not supported for 2020.

Clocks

Time since engine start FIT_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2001 to 2007, 2012, 2014 to 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2008 to 2011, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018 to 2020, 2022.

Time since engine start FIT_RUNTM_PCMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Time since engine start FIT_RUNTM_V2Confirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2008, 2020, 2022. Supported for 2007, 2009 to 2014, 2018 to 2019.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2010, 2013, 2018, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2010, 2013, 2018, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2010, 2013. Supported for 2007, 2011 to 2012, 2014.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2010, 2022. Supported for 2007, 2011 to 2014, 2018 to 2019.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2010, 2022. Supported for 2007, 2011 to 2014, 2018 to 2019.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2007 to 2011, 2013, 2018 to 2020, 2022. Supported for 2012, 2014.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2007 to 2011, 2018, 2020. Supported for 2012 to 2014, 2019, 2022.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008 to 2009. Supported for 2007, 2010 to 2014, 2018 to 2019, 2022.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007 to 2011, 2013, 2018, 2020. Supported for 2012, 2014, 2019, 2022.

ECU

Knock control FIT_KNOCK_CTRL_PCMConfirmed

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 1 FIT_MIS_1_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 2 FIT_MIS_2_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 3 FIT_MIS_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 4 FIT_MIS_4_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 5 FIT_MIS_5_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count, cylinder 6 FIT_MIS_6_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Variable valve control FIT_VTEC_CTRLConfirmed

  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007, 2018, 2022.

Electrical

Brake fluid pressure FIT_BRK_FLD_PConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Brake pedal stroke FIT_BRK_PED_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Brake pressure FIT_BRK_PConfirmed

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2001 to 2017, 2020 to 2021, 2023 to 2026

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

Confirmed for 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Brake switch FIT_BRK_SWConfirmed

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2001 to 2017, 2020 to 2021, 2023 to 2026

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Master cylinder stroke FIT_MSTR_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Slave cylinder stroke FIT_SLV_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Engine

A/C clutch FIT_AC_CLU_PCMConfirmed

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

A/C clutch FIT_AC_CLUTCHConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2008 to 2010, 2020, 2022. Supported for 2007, 2011 to 2014, 2018 to 2019.

Active cylinders FIT_ACTIVE_CYLConfirmed

  • Service 22DID 2615
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2018, 2021 to 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

Confirmed for 2019. In testing for 2001 to 2006, 2014 to 2017, 2021, 2023 to 2026. Supported for 2020. Not supported for 2007 to 2008, 2013, 2018, 2022.

Active cylinders FIT_ACTIVE_CYL_PCMConfirmed

  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2019, 2021, 2023 to 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

Confirmed for 2020, 2022. In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Air conditioner clutch FIT_AC_CLU

  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2008 to 2011. Supported for 2012 to 2014.

Air/gas ratio FIT_AIRGAS_RAT_PCMConfirmed

  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Air/gas ratio FIT_AIRGAS_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Air/gas ratio FIT_AIRGAS_RATIO_V2Confirmed

  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Ambient air temperature, cabin FIT_AAT_CABConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Ambient air temperature, outside FIT_AAT_OUTConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007 to 2011, 2018 to 2020, 2022. Supported for 2012 to 2014.

Catalyst temperature FIT_CAT_TConfirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 1500 °C
Unit
°C

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2008, 2010. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2007 to 2011, 2018 to 2020, 2022. Supported for 2012 to 2014.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2010. Supported for 2007, 2009, 2011 to 2014.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2007 to 2010, 2020, 2022. Supported for 2011 to 2014.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2022. Supported for 2018 to 2019.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2022. Supported for 2018 to 2019.

Engine oil level FIT_ENG_OIL_LEVEL

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 mm
Unit
mm

In testing for 2001 to 2007, 2012 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2011, 2018, 2020, 2022.

Engine oil temperature FIT_EOT

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2012 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2011, 2018, 2020, 2022.

Engine oil temperature, variant 3 FIT_EOT_VAR_3

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Engine oil temperature, variant 3 FIT_EOT_VAR_3_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2022.

Engine oil temperature, variant 4 FIT_EOT_VAR_4

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Engine oil temperature, variant 4 FIT_EOT_VAR_4_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2022.

Engine oil temperature,, variant 2 FIT_EOT_VAR_2

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2007, 2012 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2011, 2018, 2020, 2022.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2008 to 2010, 2020, 2022. Supported for 2007, 2011 to 2014, 2018 to 2019.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2008, 2010. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019.

Fuel/air commanded equivalence ratio FIT_FUELAIR_CARConfirmed

  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Fuel/air commanded equivalence ratio FIT_FUELAIR_CAR_PCMConfirmed

  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Generator FIT_GEN

  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2022.

Generator FIT_GENERATORConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Generator FIT_GENERATOR_PCMConfirmed

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008, 2010. Supported for 2007, 2009, 2011 to 2014.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Knock control FIT_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Raw value

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Knock control FIT_KNOCK_CONTROL_V2Confirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val×1.99255
Range
0 to 1.99
Unit
Number

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008 to 2010, 2020. Supported for 2007, 2011 to 2014, 2018 to 2019, 2022.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Maintenance, air cleaner FIT_MAINT_AIR_CLN

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, cabin filter FIT_MAINT_CABIN_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, engine coolant FIT_MAINT_COOL

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, general inspection FIT_MAINT_INSP

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, oil & filter FIT_MAINT_OIL_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, rake fluid FIT_MAINT_BRK_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, spark plugs & valves FIT_MAINT_SPARK

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Maintenance, transmission fluid FIT_MAINT_TRANS_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2022. Supported for 2019.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2022. Supported for 2019.

Misfire count #1 FIT_MIS_1Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Misfire count #1, variant 1 FIT_MIS_CNT_1_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #1, variant 3 FIT_MIS_CNT_1_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #2 FIT_MIS_2Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Misfire count #2, variant 1 FIT_MIS_CNT_2_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #2, variant 3 FIT_MIS_CNT_2_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #3 FIT_MIS_3Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Misfire count #3, variant 1 FIT_MIS_CNT_3_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #3, variant 3 FIT_MIS_CNT_3_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #4 FIT_MIS_4Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Misfire count #4, variant 1 FIT_MIS_CNT_4_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #4, variant 3 FIT_MIS_CNT_4_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #5, variant 1 FIT_MIS_CNT_5_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #5, variant 3 FIT_MIS_CNT_5_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #6, variant 1 FIT_MIS_CNT_6_VAR_1_PCMConfirmed

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count #6, variant 3 FIT_MIS_CNT_6_VAR_3_PCMConfirmed

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Misfire count 1 FIT_MIS_CNT_1

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2001 to 2009, 2011 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Supported for 2010. Not supported for 2008 to 2009, 2018, 2022.

Misfire count 1,, variant 1 FIT_MIS_CNT_1_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 1,, variant 2 FIT_MIS_CNT_1_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 1,, variant 3 FIT_MIS_CNT_1_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 2 FIT_MIS_CNT_2

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2001 to 2009, 2011 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Supported for 2010. Not supported for 2008 to 2009, 2018, 2022.

Misfire count 2,, variant 1 FIT_MIS_CNT_2_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 2,, variant 2 FIT_MIS_CNT_2_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 2,, variant 3 FIT_MIS_CNT_2_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 3 FIT_MIS_CNT_3

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2001 to 2009, 2011 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Supported for 2010. Not supported for 2008 to 2009, 2018, 2022.

Misfire count 3,, variant 1 FIT_MIS_CNT_3_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 3,, variant 2 FIT_MIS_CNT_3_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 3,, variant 3 FIT_MIS_CNT_3_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 4 FIT_MIS_CNT_4

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2001 to 2009, 2011 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Supported for 2010. Not supported for 2008 to 2009, 2018, 2022.

Misfire count 4,, variant 1 FIT_MIS_CNT_4_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 4,, variant 2 FIT_MIS_CNT_4_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 4,, variant 3 FIT_MIS_CNT_4_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 5,, variant 1 FIT_MIS_CNT_5_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 5,, variant 2 FIT_MIS_CNT_5_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 5,, variant 3 FIT_MIS_CNT_5_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 6,, variant 1 FIT_MIS_CNT_6_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 6,, variant 2 FIT_MIS_CNT_6_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Misfire count 6,, variant 3 FIT_MIS_CNT_6_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Oil pressure FIT_OIL_P

  • Service 22DID 2203
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2020, 2022.

Relative Throttle A Position TP_A_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Relative Throttle B Position TP_B_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2007 to 2011, 2018 to 2020, 2022. Supported for 2012 to 2014.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2008, 2010, 2020. Supported for 2007, 2009, 2011 to 2014, 2018 to 2019, 2022.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2020. Supported for 2014, 2018 to 2019, 2022.

Variable timing control duty FIT_VARIABLE_TIM_CTRLConfirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bits 224 to 231 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Variable timing control duty FIT_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2001 to 2007, 2012, 2014 to 2018, 2020 to 2026

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2011, 2013, 2019. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018, 2020, 2022.

Variable valve timing duty FIT_VTC_DUTY_PCMConfirmed

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

VTEC valve control FIT_VTEC_VALVE_CTRLConfirmed

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 2001 to 2007, 2009, 2011 to 2012, 2014 to 2026

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2008, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007, 2009, 2011, 2018 to 2020, 2022.

Internal

Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2020, 2022. Supported for 2018 to 2019.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2020, 2022. Supported for 2018 to 2019.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2022. Supported for 2019.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2022. Supported for 2019.

Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2022.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2007 to 2011. Supported for 2013 to 2014.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2018 to 2019, 2022.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2008. Supported for 2007, 2009 to 2014, 2018 to 2019, 2022.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2007 to 2011. Supported for 2013 to 2014.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2018 to 2019, 2022.

Fuel

Air-fuel mixture heater FIT_AIR_FUEL_MIXTUREConfirmed

  • Service 22DID 266D
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Fuel level FIT_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 2001 to 2017, 2021, 2023 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

Confirmed for 2018 to 2020, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2008 to 2010. Supported for 2007, 2011 to 2014, 2018 to 2019, 2022.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2008 to 2010. Supported for 2007, 2011 to 2014, 2018 to 2019, 2022.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007 to 2010, 2018, 2020, 2022. Supported for 2011 to 2014, 2019.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2007 to 2011, 2013, 2018 to 2020, 2022. Supported for 2012, 2014.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2008 to 2011, 2013, 2018, 2020. Supported for 2007, 2012, 2014, 2019, 2022.

Tires

Maintenance, tire rotation FIT_MAINT_TIRE

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013, 2018 to 2019, 2022.

Transmission

Current gear FIT_GEAR_1D

  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018, 2020, 2022.

Current gear, variant 2 FIT_CURRENT_GEAR_VAR_2Confirmed

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing for 2001 to 2019, 2021, 2023 to 2026

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020, 2022. In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Current gear, variant 3 FIT_CURRENT_GEAR_VAR_3Confirmed

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing for 2001 to 2019, 2021, 2023 to 2026

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020, 2022. In testing for 2001 to 2007, 2011 to 2017, 2019, 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Transmission fluid temperature FIT_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2001 to 2012, 2014 to 2026

Bits 208 to 215 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007 to 2011, 2018 to 2020, 2022.

Trips

Odometer FIT_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2001 to 2007, 2012, 2014 to 2026

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2008 to 2011, 2013. In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Not supported for 2007, 2018 to 2020, 2022.

Odometer FIT_ODO_PCMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2022. In testing for 2001 to 2007, 2011 to 2017, 2019 to 2021, 2023 to 2026. Not supported for 2008 to 2010, 2018.

Odometer FIT_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA1D → 1D
  • Every5 s
  • Testing for 2001 to 2009, 2011 to 2026

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2006, 2012, 2014 to 2017, 2021, 2023 to 2026. Supported for 2010. Not supported for 2007 to 2009, 2011, 2013, 2018 to 2020, 2022.

Odometer FIT_ODO_V3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 7022
  • ModuleDA60 → 60
  • Every1 s
  • Testing for 2001 to 2017, 2020 to 2021, 2023 to 2026

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 200000 mi
Unit
mi

Confirmed for 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.