Kia Sonet

Parameters

The Kia Sonet has 489 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12v battery voltage SONET_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0xB1 = 177 → 17712.8 = 13.828125 V

Confirmed for 2026. In testing for 2020 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12v battery charge SONET_VPWR_V3

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

12V battery current SONET_12V_BAT_CURRENT

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1831500000
Range
-119 to 119 A
Unit
A

In testing for 2020 to 2026.

12V battery state of charge SONET_12V_BAT_ST_CHG

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

12V battery state of function SONET_12V_BAT_ST_FUNCTION

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 V
Unit
V

In testing for 2020 to 2026.

12V battery state of health SONET_12V_BAT_ST_HEALTH

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

12V battery temperature SONET_12V_BAT_T

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2026.

12V battery voltage SONET_12V_BAT_V

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2020 to 2026.

12v battery voltage SONET_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0xB1 = 177 → 17712.8 = 13.828125 V

Confirmed for 2026. In testing for 2020 to 2025.

Aux battery state of charge SONET_AUX_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Supported for 2026.

Aux battery state of health SONET_AUX_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Supported for 2026.

Battery capacity, battery sensor SONET_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2020 to 2026.

Battery charge flag, battery sensor SONET_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery current SONET_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2020 to 2026.

Battery current, battery sensor SONET_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2020 to 2026.

Battery current, battery sensor SONET_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2020 to 2026.

Battery health aging flag, battery sensor SONET_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery is in use to crank the engine flag, battery sensor SONET_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery quiescent current flag, battery sensor SONET_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery sensor invalid condition flag, battery sensor SONET_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery state of charge SONET_BATTERY_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0xE6 = 230 → 230×100255 = 90.196078 %

Confirmed for 2026. In testing for 2020 to 2025.

Battery state of charge, battery sensor SONET_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Battery state of charge, battery sensor SONET_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Battery state of function, battery sensor SONET_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2020 to 2026.

Battery state of health, battery sensor SONET_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Battery state of health, battery sensor SONET_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Battery temperature SONET_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2020 to 2026.

Battery temperature, battery sensor SONET_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2020 to 2026.

Battery temperature, battery sensor SONET_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2020 to 2026.

Battery voltage SONET_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2020 to 2026.

Battery voltage SONET_BATTERY_VConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xBE = 190 → 190×17.37255 = 12.942353 V

Confirmed for 2026. In testing for 2020 to 2025.

Battery voltage after ignition SONET_BATTERY_V_AFTER_IGNITIONConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xBE = 190 → 190×17.37255 = 12.942353 V

Confirmed for 2026. In testing for 2020 to 2025.

Battery voltage, battery sensor SONET_BAT_V_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2020 to 2026.

Battery voltage, battery sensor SONET_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2020 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2026.

DC charging state SONET_DC_CHRG_STATE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 140 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Gasoline particulate filter charge state SONET_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter inlet temperature sensor raw voltage SONET_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2020 to 2026.

Gasoline particulate filter outlet temperature sensor raw voltage SONET_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2020 to 2026.

Relative accelerator pedal position voltage SONET_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Response error from battery sensor flag, battery sensor SONET_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Supply voltage SONET_SUPPLY_VOLTAGE

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

System voltage SONET_SYSTEM_VOLTAGE

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Throttle position sensor voltage #1 SONET_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Throttle position sensor voltage #2 SONET_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Waste gate voltage SONET_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2020 to 2026.

Wastegate position voltage SONET_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2020 to 2026.

Climate

Defogging? SONET_DEFOG_SWConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Exterior temperature SONET_TEMP_EXTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 80 °C
Unit
°C

0x8A = 138 → 1382−40 = 29 °C

Confirmed for 2026. In testing for 2020 to 2025.

Heated steering wheel SONET_HEATED_WHEEL

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Heated steering wheel, alternate bit SONET_HEATED_WHEEL_ALT

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Interior temperature SONET_TEMP_INTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 80 °C
Unit
°C

0x7D = 125 → 1252−40 = 22.5 °C

Confirmed for 2026. In testing for 2020 to 2025.

Interior temperature, passenger legs vent SONET_HVAC_IAT_PASSENGER_LEGS_VENTConfirmed

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0xFF = 255 → 2552−40 = 87.5 °C

Confirmed for 2026. In testing for 2020 to 2025.

Interior temperature, passenger vent SONET_HVAC_IAT_PASSENGER_VENTConfirmed

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0xFF = 255 → 2552−40 = 87.5 °C

Confirmed for 2026. In testing for 2020 to 2025.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Brake booster pressure SONET_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2020 to 2026.

Brake pressure SONET_BRAKE_P_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

0x0282 = 642 → 64286.7 = 7.404844 %

Confirmed for 2026. In testing for 2020 to 2025.

Brake switch SONET_BRAKE_SW

  • Service 22DID B008
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Handbrake engaged? SONET_HANDBRAKEConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Relative accelerator pedal position SONET_APP_REL_AWD

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Steering wheel angle SONET_STEER_ANGLE_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0045 = 69 → 6910 = 6.9 °

Confirmed for 2026. In testing for 2020 to 2025.

Steering wheel angle SONET_STEER_ANGLE_V3

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Doors

Front left door locked? SONET_LOCK_FLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Front left door open? SONET_DOOR_FLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Front right door locked? SONET_LOCK_FRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Front right door open? SONET_DOOR_FRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Hood latched? SONET_HOODConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Rear left door open? SONET_DOOR_RLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 39 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Rear right door open? SONET_DOOR_RRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Trunk open? SONET_TRUNKConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2026.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2026.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2026.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2026.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2026.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Engine

4WD clutch duty SONET_AWD_CLU_DUTY

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 %
Unit
%

In testing for 2020 to 2026.

4WD clutch pressure SONET_AWD_CLU_P

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
val×0.001953
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2020 to 2026.

4WD clutch stress SONET_AWD_CLU_STRESS

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val×0.001953
Range
-63.99 to 63.99 %
Unit
%

In testing for 2020 to 2026.

4WD clutch torque SONET_AWD_CLU_TQ

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 N·m
Unit
N·m

In testing for 2020 to 2026.

4WD front axle ratio SONET_AWD_FRONT_AXLE_RAT

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val×265535
Range
-1 to 0.999
Unit
Number

In testing for 2020 to 2026.

Adaptation value for lower stop of wastegate actuator SONET_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2020 to 2026.

Air conditioning pressure SONET_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×13.79
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2020 to 2026.

Air conditioning relay SONET_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Automatic transmission fluid temperature SONET_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x74 = 116 → 116−40 = 76 °C

Confirmed for 2026. In testing for 2020 to 2025.

Barometric pressure SONET_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2020 to 2025. Not supported for 2026.

Boost pressure SONET_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure upstream SONET_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure upstream, desired SONET_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2020 to 2026.

Brake pedal SONET_BRAKE_PEDALConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xF1 = 241 → 241

Confirmed for 2026. In testing for 2020 to 2025.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Calculated oil temperature SONET_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Camshaft exhaust position, actual SONET_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2020 to 2026.

Camshaft exhaust position, commanded SONET_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2020 to 2026.

Camshaft intake position, actual SONET_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2020 to 2026.

Camshaft intake position, commanded SONET_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2020 to 2026.

Catalyst damaging misfires total all cylinders SONET_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Catalyst damaging misfires total all cylinders SONET_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 1 SONET_CATALYST_DAMAGING_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Catalyst damaging misfires total, cylinder 1 SONET_CATDMG_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 2 SONET_CATALYST_DAMAGING_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Catalyst damaging misfires total, cylinder 2 SONET_CATDMG_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 3 SONET_CATALYST_DAMAGING_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Catalyst damaging misfires total, cylinder 3 SONET_CATDMG_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 4 SONET_CATALYST_DAMAGING_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Catalyst damaging misfires total, cylinder 4 SONET_CATDMG_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Clutch solenoid duty SONET_CLUTCH_SOLENOID_DUTY

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2026.

Commanded evaporative purge SONET_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Commanded throttle actuator SONET_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Commanded torque SONET_COMMANDED_TORQUE

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 N·m
Unit
N·m

In testing for 2020 to 2025. Not supported for 2026.

Coolant SONET_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Coolant fan PWM SONET_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×15.2110000
Range
0 to 99.67 %
Unit
%

In testing for 2020 to 2026.

Coolant temperature SONET_HVAC_COOLANT_TConfirmed

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0xFF = 255 → 2552−40 = 87.5 °C

Confirmed for 2026. In testing for 2020 to 2025.

Coverage driven length SONET_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Crankshaft torque SONET_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder 1 injection time, 1st pulse SONET_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 1 injection time, 2nd pulse SONET_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 2 injection time, 1st pulse SONET_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 2 injection time, 2nd pulse SONET_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 3 injection time, 1st pulse SONET_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 3 injection time, 2nd pulse SONET_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 4 injection time, 1st pulse SONET_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 4 injection time, 2nd pulse SONET_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Diesel particulate filter differential pressure SONET_DPF_DIFFERENTIAL_PRESSURE

  • Service 21PID 1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5
Unit
Raw value

In testing for 2020 to 2025. Not supported for 2026.

Diesel particulate filter regeneration count SONET_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration state SONET_DPF_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Diesel particulate filter regeneration state SONET_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Diesel particulate filter successful regeneration count SONET_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Direct injection time 1 SONET_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 2 SONET_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 3 SONET_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 4 SONET_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a SONET_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b SONET_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Dual-clutch transmission fluid temperature 1 SONET_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Dual-clutch transmission fluid temperature 2 SONET_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Dual-clutch transmission line pressure, sensor c SONET_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Emission relevant misfires total all cylinders SONET_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total all cylinders SONET_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Emission relevant misfires total, cylinder 1 SONET_EMIS_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 1 SONET_EMISSION_RELEVANT_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Emission relevant misfires total, cylinder 2 SONET_EMIS_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 2 SONET_EMISSION_RELEVANT_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Emission relevant misfires total, cylinder 3 SONET_EMIS_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 3 SONET_EMISSION_RELEVANT_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Emission relevant misfires total, cylinder 4 SONET_EMIS_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 4 SONET_EMISSION_RELEVANT_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Engine oil temperature SONET_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 272 to 279 of the reply, 8 bits.

Formula
val1.3333−48
Range
0 to 143.254781 °C
Unit
°C

0xC7 = 199 → 1991.3333−48 = 101.253731 °C

Confirmed for 2026. In testing for 2020 to 2025.

Engine oil temperature SONET_EOT_7E0

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature SONET_EOT_7E0_2

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature SONET_EOT_V2

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 215 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Engine RPM SONET_RPM_7E5

Pelican can show this parameter as the engine speed.

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2025. Not supported for 2026.

Engine run time, total SONET_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2020 to 2026.

Engine, actual torque SONET_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2352910000
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2020 to 2026.

Exhaust cam oil control valve duty SONET_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust camshaft position SONET_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2026.

Exhaust gas temperature SONET_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Exhaust gas temperature before gasoline particulate filter sensor 1 SONET_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 SONET_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst SONET_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust temperature 2, upstream of DPF SONET_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2020 to 2026.

Gasoline direct injection time bank a, 1 SONET_GDI_IT_A1Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank a, 2 SONET_GDI_IT_A2Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank a, 3 SONET_GDI_IT_A3Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank a, 4 SONET_GDI_IT_A4Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank b, 1 SONET_GDI_IT_B1Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank b, 2 SONET_GDI_IT_B2Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank b, 3 SONET_GDI_IT_B3Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Gasoline direct injection time bank b, 4 SONET_GDI_IT_B4Confirmed

  • Service 22DID E005
  • Module7E0
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2026. In testing for 2020 to 2025.

Heat SONET_HEAT_7E5

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Idle control mode SONET_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Ignition retard due to knock control 1 SONET_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 2 SONET_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 3 SONET_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 4 SONET_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Injection duration cylinder 1 SONET_INJ_DUR_1Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.686409 ms
Unit
ms

Confirmed for 2026. In testing for 2020 to 2025.

Injection duration cylinder 2 SONET_INJ_DUR_2Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.686409 ms
Unit
ms

Confirmed for 2026. In testing for 2020 to 2025.

Injection duration cylinder 3 SONET_INJ_DUR_3Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.686409 ms
Unit
ms

Confirmed for 2026. In testing for 2020 to 2025.

Injection duration cylinder 4 SONET_INJ_DUR_4Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.686409 ms
Unit
ms

Confirmed for 2026. In testing for 2020 to 2025.

Injection impulse 1, cylinder 1 SONET_INJ_IMPULSE_1_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 2 SONET_INJ_IMPULSE_1_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 3 SONET_INJ_IMPULSE_1_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 4 SONET_INJ_IMPULSE_1_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 1 SONET_INJ_IMPULSE_2_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 2 SONET_INJ_IMPULSE_2_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 3 SONET_INJ_IMPULSE_2_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 4 SONET_INJ_IMPULSE_2_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 1 SONET_INJ_IMPULSE_3_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 2 SONET_INJ_IMPULSE_3_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 3 SONET_INJ_IMPULSE_3_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 4 SONET_INJ_IMPULSE_3_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injector correction factor 1 SONET_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 2 SONET_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 3 SONET_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 4 SONET_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Intake air temperature SONET_EITConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 264 to 271 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x97 = 151 → 151×34−48 = 65.25 °C

Confirmed for 2026. In testing for 2020 to 2025.

Intake cam oil control valve duty SONET_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Intake camshaft position SONET_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft position actual SONET_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Intake camshaft position commanded SONET_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Inverter temperature SONET_HVAC_INVERTER_TConfirmed

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0xFF = 255 → 2552−40 = 87.5 °C

Confirmed for 2026. In testing for 2020 to 2025.

Knock detected SONET_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Knock learn cylinder 1 SONET_KNOCK_LEARN_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock learn cylinder 2 SONET_KNOCK_LEARN_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock learn cylinder 3 SONET_KNOCK_LEARN_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock learn cylinder 4 SONET_KNOCK_LEARN_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock retard cylinder #1 SONET_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder #2 SONET_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder #3 SONET_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder #4 SONET_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder 1 SONET_KNOCK_RETARD_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock retard cylinder 1 SONET_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 1, alternate SONET_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder 1, alternate SONET_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 2 SONET_KNOCK_RETARD_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock retard cylinder 2 SONET_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 2, alternate SONET_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder 2, alternate SONET_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 3 SONET_KNOCK_RETARD_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock retard cylinder 3 SONET_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 3, alternate SONET_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder 3, alternate SONET_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 4 SONET_KNOCK_RETARD_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2026. In testing for 2020 to 2025.

Knock retard cylinder 4 SONET_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 4, alternate SONET_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Knock retard cylinder 4, alternate SONET_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Lock switch SONET_LOCK_SWITCH_7E5

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Main injection volume SONET_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2020 to 2025. Not supported for 2026.

Malfunction indicator SONET_MALFUNCTION_INDICATOR

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Mass air flow rate SONET_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2020 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running SONET_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop SONET_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running SONET_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop SONET_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Misfire count #1 SONET_MIS_1

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfire count #2 SONET_MIS_2

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfire count #3 SONET_MIS_3

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfire count #4 SONET_MIS_4

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires current total SONET_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 1 SONET_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 2 SONET_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 3 SONET_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 4 SONET_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 1 SONET_MIS_HARMFUL_CAT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 2 SONET_MIS_HARMFUL_CAT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 3 SONET_MIS_HARMFUL_CAT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 4 SONET_MIS_HARMFUL_CAT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, current, cylinder 1 SONET_MISFIRES_C1_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Misfires, current, cylinder 2 SONET_MISFIRES_C2_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Misfires, current, cylinder 3 SONET_MISFIRES_C3_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Misfires, current, cylinder 4 SONET_MISFIRES_C4_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Misfires, cylinder 1 SONET_MIS_1_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 SONET_MIS_2_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 SONET_MIS_3_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 SONET_MIS_4_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Motor-driven power steering current SONET_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x03 = 3 → 3 A

Confirmed for 2026. In testing for 2020 to 2025.

Oil pump PWM SONET_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2020 to 2026.

Overheat protection, active SONET_OVERHEAT_PROTECTION

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Oxygen sensor 1 bank 1 SONET_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Oxygen sensor 2 bank 1 SONET_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Parking sensor rear center left level SONET_PARKING_SENS_REAR

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Parking sensor rear center right level SONET_PARKING_SENS_REAR_CENTER

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Pilot injection volume SONET_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2020 to 2025. Not supported for 2026.

Post injection volume SONET_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2020 to 2025. Not supported for 2026.

Pressure sensor SONET_PRESSURE_SENSOR

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2020 to 2025. Not supported for 2026.

Rail pressure control valve SONET_RAIL_P_CTRL_VLV

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
val×2051
Range
0 to 0.3921
Unit
Off or on

In testing for 2020 to 2026.

Requested torque SONET_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Requested torque limitation from traction control SONET_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2026.

Throttle position #1 SONET_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Throttle position #2 SONET_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Timing advance #1 SONET_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Timing advance #2 SONET_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Timing advance #3 SONET_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Timing advance #4 SONET_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Torque converter slip SONET_TORQUE_CONVERTER_SLIPConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

0x11F8 = 4600 → 46004−512 = 638 rpm

Confirmed for 2026. In testing for 2020 to 2025.

Torque converter slip SONET_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque, actual SONET_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2020 to 2026.

Transmission fluid temperature SONET_ATF_T_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Turbo boost pressure SONET_TURBO_BOOST

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val831.556909−12
Range
-10 to 66.81 psi
Unit
psi

In testing for 2020 to 2025. Not supported for 2026.

Turbo boost pressure SONET_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2020 to 2026.

Turbo boost pressure SONET_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2020 to 2026.

Variable valve timing temperature SONET_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7D8
  • Every250 ms
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Waste gate duty SONET_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2020 to 2026.

Waste gate duty SONET_WG_DUTY

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×20065535
Range
0 to 200 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Waste gate position SONET_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2020 to 2026.

Waste gate position SONET_WG_POSITION

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 199.99 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Waste gate setpoint SONET_WG_SETPOINT

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Waste gate target SONET_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2020 to 2026.

Waste gate voltage SONET_WG_VOLTAGE

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×1065535
Range
0 to 10 V
Unit
V

In testing for 2020 to 2025. Not supported for 2026.

Wastegate control PWM, wastegate actuator SONET_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2020 to 2026.

Wastegate position target, wastegate actuator SONET_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2020 to 2026.

Wastegate position, wastegate actuator SONET_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2020 to 2026.

Misfires

Emission-relevant misfires, cylinder #1 SONET_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Emission-relevant misfires, cylinder #2 SONET_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Emission-relevant misfires, cylinder #3 SONET_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Emission-relevant misfires, cylinder #4 SONET_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires harmful for catalyst cylinder 1 SONET_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires harmful for catalyst cylinder 2 SONET_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires harmful for catalyst cylinder 3 SONET_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires harmful for catalyst cylinder 4 SONET_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires total counter, all cylinders SONET_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires total counter, cylinder #1 SONET_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires total counter, cylinder #2 SONET_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires total counter, cylinder #3 SONET_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires total counter, cylinder #4 SONET_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires, cylinder 1 SONET_MIS_1_7E0_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires, cylinder 2 SONET_MIS_2_7E0_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires, cylinder 3 SONET_MIS_3_7E0_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Misfires, cylinder 4 SONET_MIS_4_7E0_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2026.

Unknown

Unknown SONET_22E004Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x3F = 63 → 63

Confirmed for 2026. In testing for 2020 to 2025.

Fuel

Cycle fuel consumption SONET_CYCLE_FUEL_CONS

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
val×8.478100
Range
0 to 21.6189
Unit
Raw value

In testing for 2020 to 2026.

Fuel consumption since last DPF regeneration SONET_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2020 to 2026.

Fuel cut SONET_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Fuel injection timing #1 SONET_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2020 to 2025. Not supported for 2026.

Fuel injection timing #2 SONET_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2020 to 2025. Not supported for 2026.

Fuel injection timing #3 SONET_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2020 to 2025. Not supported for 2026.

Fuel injection timing #4 SONET_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2020 to 2025. Not supported for 2026.

Fuel level SONET_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x1C = 28 → 282 = 14 L

Confirmed for 2026. In testing for 2020 to 2025.

Fuel level input SONET_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2020 to 2026.

Fuel pressure SONET_FUEL_P

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2020 to 2026.

Fuel pressure deviation SONET_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2020 to 2026.

Fuel pressure set point SONET_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2020 to 2026.

Fuel pressure set point deviation SONET_FUEL_P_SET_POINT_DEV

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306610000
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2020 to 2026.

Fuel pressure, actual SONET_FUEL_P_ACT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2020 to 2026.

Fuel pressure, set point SONET_FUEL_P_SET_POINT_7E0

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2020 to 2026.

Fuel temperature SONET_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×784310000−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2020 to 2026.

Short term fuel % trim, bank 1 SONET_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Short term fuel % trim, bank 1 idle SONET_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Lights

Brake light SONET_BRAKE_LIGHTConfirmed

  • Service 22DID BC06
  • Module770 → 778
  • Every250 ms
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Defog light SONET_DEFOG_LIGHTConfirmed

  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Exterior lights state code SONET_LIGHTS_CODE

  • Service 22DID BC10
  • Module770 → 778
  • Every5 s
  • Testing

Bits 32 to 35 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2020 to 2026.

Hazard switch SONET_HAZARD_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Headlight high beam SONET_HL_HIGHConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Headlight low beam SONET_HL_LOWConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Headlight switch SONET_HL_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026. In testing for 2020 to 2025.

Left turn signal on? SONET_TURN_LConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Right turn signal on? SONET_TURN_RConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Movement

4WD delta speed between front and rear axle SONET_AWD_AXLE_SPD_DIFF

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 rpm
Unit
rpm

In testing for 2020 to 2026.

Actual acceleration SONET_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2020 to 2026.

Average wheel speed SONET_VSS_AVG_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Coolant fan high speed SONET_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Coolant fan high speed, 1.8 SONET_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Coolant fan low speed SONET_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Coolant fan low speed, 1.8 SONET_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2025. Not supported for 2026.

Engine coolant fan high speed, on/off SONET_ENG_CLT_FAN_HIGH_SPD_ON_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine coolant fan low speed SONET_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine RPM SONET_RPMConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x09F8 = 2552 → 25524 = 638 rpm

Confirmed for 2026. In testing for 2020 to 2025.

Front left wheel speed SONET_FL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front left wheel speed SONET_FRONT_LEFT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front left wheel speed SONET_TIRE_FL_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front left wheel speed SONET_TIRE_FL_VSS

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every100 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front left wheel speed SONET_TIRE_FL_VSS_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Front right wheel speed SONET_FR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front right wheel speed SONET_FRONT_RIGHT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front right wheel speed SONET_TIRE_FR_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front right wheel speed SONET_TIRE_FR_VSS

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every100 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front right wheel speed SONET_TIRE_FR_VSS_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Output speed SONET_OUTPUT_RPMConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2026. In testing for 2020 to 2025.

Output speed SONET_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Rear left wheel speed SONET_REAR_LEFT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear left wheel speed SONET_RL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear left wheel speed SONET_TIRE_RL_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear left wheel speed SONET_TIRE_RL_VSS

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every100 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear left wheel speed SONET_TIRE_RL_VSS_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Rear right wheel speed SONET_REAR_RIGHT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear right wheel speed SONET_RR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear right wheel speed SONET_TIRE_RR_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear right wheel speed SONET_TIRE_RR_VSS

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every100 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear right wheel speed SONET_TIRE_RR_VSS_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Relative accelerator pedal position SONET_RELATIVE_ACCELERATOR_PEDAL_POSITIONConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2026. In testing for 2020 to 2025.

Relative accelerator pedal position SONET_RELATIVE_ACCELERATOR_PEDAL_POSITION_7E0

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2025. Not supported for 2026.

Traction control switch, raw SONET_TC_SWITCH_V2Confirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Turbine speed SONET_TURBINE_SPDConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2026. In testing for 2020 to 2025.

Turbine speed SONET_TURBINE_SPD_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Vehicle speed SONET_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x14 = 20 → 20 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Vehicle speed SONET_VSS_7E1Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2026. In testing for 2020 to 2025.

Vehicle speed SONET_VSS_AWD

Pelican can show this parameter as the speed.

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Vehicle speed SONET_VSS_V2_7E2

Current vehicle speed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-180 to 180 mph
Unit
mph

In testing for 2020 to 2025. Not supported for 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2026.

Vehicle speed, v2 SONET_VSS_V2_7E0

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2026.

Seatbelts

Driver seatbelt latched? SONET_BELT_DRIVConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Passenger seatbelt latched? SONET_BELT_PASSConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Rear left seatbelt latched? SONET_BELT_RLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Rear middle seatbelt latched? SONET_BELT_RMConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 52 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Rear right seatbelt latched? SONET_BELT_RRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Tires

4WD steering wheel angle SONET_AWD_STEER_WHL_ANG

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 184 to 199 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 °
Unit
°

In testing for 2020 to 2026.

Front left tire pressure SONET_FL_TP

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2020 to 2025. Not supported for 2026.

Front left tire pressure SONET_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2020 to 2025. Not supported for 2026.

Front left tire reading invalid? SONET_FL_INVALID

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bit 70 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2025. Not supported for 2026.

Front left tire temperature SONET_FL_TT

Pelican can show this parameter as the front left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Front left tire temperature SONET_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Front left wheel speed SONET_FL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Front right tire pressure SONET_FR_TP

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2020 to 2025. Not supported for 2026.

Front right tire pressure SONET_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2020 to 2025. Not supported for 2026.

Front right tire reading invalid? SONET_FR_INVALID

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2025. Not supported for 2026.

Front right tire temperature SONET_FR_TT

Pelican can show this parameter as the front right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Front right tire temperature SONET_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Front right wheel speed SONET_FR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear left tire pressure SONET_RL_TP

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2020 to 2025. Not supported for 2026.

Rear left tire pressure SONET_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2020 to 2025. Not supported for 2026.

Rear left tire reading invalid? SONET_RL_INVALID

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2025. Not supported for 2026.

Rear left tire temperature SONET_RL_TT

Pelican can show this parameter as the rear left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Rear left tire temperature SONET_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Rear left wheel speed SONET_RL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Rear right tire pressure SONET_RR_TP

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2020 to 2025. Not supported for 2026.

Rear right tire pressure SONET_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2020 to 2025. Not supported for 2026.

Rear right tire reading invalid? SONET_RR_INVALID

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2025. Not supported for 2026.

Rear right tire temperature SONET_RR_TT

Pelican can show this parameter as the rear right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Rear right tire temperature SONET_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Rear right wheel speed SONET_RR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Steering wheel angle SONET_STEERING_WHEEL_ANGLE

  • Service 21PID C0
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val−88
Range
-88 to 167 °
Unit
°

In testing for 2020 to 2025. Not supported for 2026.

Tire battery front left SONET_TB_FL

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
03V+>3 V
127_3V2.7 - 3 V
22_4_2_7V2.4 - 2.7 V
32_4-< 2.4

In testing for 2020 to 2025. Not supported for 2026.

Tire battery front right SONET_TB_FR

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
03V+>3 V
127_3V2.7 - 3 V
22_4_2_7V2.4 - 2.7 V
32_4-< 2.4

In testing for 2020 to 2025. Not supported for 2026.

Tire battery rear left SONET_TB_RL

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
03V+>3 V
127_3V2.7 - 3 V
22_4_2_7V2.4 - 2.7 V
32_4-< 2.4

In testing for 2020 to 2025. Not supported for 2026.

Tire battery rear right SONET_TB_RR

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
03V+>3 V
127_3V2.7 - 3 V
22_4_2_7V2.4 - 2.7 V
32_4-< 2.4

In testing for 2020 to 2025. Not supported for 2026.

Tire sensor 1 ID SONET_TID_1

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Tire sensor 2 ID SONET_TID_2

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Tire sensor 3 ID SONET_TID_3

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Tire sensor 4 ID SONET_TID_4

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Wheel turn angle, absolute SONET_WHEEL_ANGLE_ABSConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x1243 = 4675 → 467510 = 467.5 °

Confirmed for 2026. In testing for 2020 to 2025.

Transmission

Automatic transmission fluid temperature SONET_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Clutch #1 temperature SONET_CLUTCH_1_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Clutch #2 temperature SONET_CLUTCH_2_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2025. Not supported for 2026.

Commanded gear SONET_COMMANDED_GEARConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2026. In testing for 2020 to 2025.

Current gear SONET_CURRENT_GEARConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2026. In testing for 2020 to 2025.

Current gear SONET_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Current gear SONET_GEAR_7E1

The automatic transmission gear.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1NEUTRALNeutral
2REVERSEReverse
3PARKPark
4MANUALManual

In testing for 2020 to 2025. Not supported for 2026.

Current gear SONET_GEAR_CUR

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Dual-clutch transmission even shaft, gear engaged SONET_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Dual-clutch transmission odd shaft, gear engaged SONET_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Gear SONET_GEARConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x08 = 8 → 8

Confirmed for 2026. In testing for 2020 to 2025.

Gear SONET_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Next gear SONET_GEAR_NXT

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2020 to 2025. Not supported for 2026.

Reverse gear selected SONET_GEAR_RConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2026. In testing for 2020 to 2025.

Transmission fluid temperature SONET_ATF_TEMP

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2020 to 2025. Not supported for 2026.

Vehicle speed SONET_VSS_7E1_21A0

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2025. Not supported for 2026.

Trips

Diesel particulate filter distance since last regeneration SONET_DPF_DIST_SINCE_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Diesel particulate filter odometer at last regeneration SONET_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Distance since last DPF regeneration SONET_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2025. Not supported for 2026.

Distance since last gasoline particulate filter regeneration SONET_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Odometer SONET_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2025. Not supported for 2026.

Odometer SONET_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Odometer SONET_ODO_KMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0015EB = 5611 → 5,611 km

Confirmed for 2026. In testing for 2020 to 2025.

Odometer SONET_ODO_MIConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2020 to 2025

Example reply from a 2026 Kia Sonet.

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

0x000000 = 0 → 0 mi

Confirmed for 2026. In testing for 2020 to 2025.

Odometer at last DPF regeneration SONET_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2025. Not supported for 2026.

Odometer at last gasoline particulate filter regeneration SONET_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Sensor 1 odometer event 1 SONET_SENS_1_ODO_EVT_1

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 1 odometer event 2 SONET_SENS_1_ODO_EVT_2

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 1 odometer event 3 SONET_SENS_1_ODO_EVT_3

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 2 odometer event 1 SONET_SENS_2_ODO_EVT_1

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 2 odometer event 2 SONET_SENS_2_ODO_EVT_2

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 2 odometer event 3 SONET_SENS_2_ODO_EVT_3

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 3 odometer event 1 SONET_SENS_3_ODO_EVT_1

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 3 odometer event 2 SONET_SENS_3_ODO_EVT_2

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 3 odometer event 3 SONET_SENS_3_ODO_EVT_3

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 4 odometer event 1 SONET_SENS_4_ODO_EVT_1

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 4 odometer event 2 SONET_SENS_4_ODO_EVT_2

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Sensor 4 odometer event 3 SONET_SENS_4_ODO_EVT_3

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2020 to 2026.

Vehicle total distance SONET_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.