Lincoln MKZ

Parameters

The Lincoln MKZ has 301 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery charge MKZ_HVBAT_SOCConfirmed

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2006 to 2011, 2013 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 100 %
Unit
%

0x4280 = 17024 → 17024500 = 34.048 %

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age MKZ_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

In testing for 2006 to 2020.

12V battery current MKZ_VEH_BAT_CURRENT

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2006 to 2020.

12V battery state of charge MKZ_12V_SOC

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

12V battery temperature MKZ_12V_T

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

In testing for 2006 to 2020.

12V battery voltage MKZ_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

In testing for 2006 to 2020.

Average battery module voltage MKZ_AVG_BAT_MODULE_V

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2006 to 2020.

Battery capacity too low for start/stop MKZ_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery current too high for start/stop MKZ_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery quiescent current, low range MKZ_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 2006 to 2020.

Battery refresh cycle in progress for start/stop MKZ_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery state detection status MKZ_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Battery state of charge too low for start/stop MKZ_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery temperature too low for auto stop MKZ_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery voltage MKZ_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2006 to 2020.

Battery voltage too low for auto restart MKZ_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery voltage too low for cold cranking capability MKZ_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Battery voltage too low for start/stop MKZ_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

Charge air temperature MKZ_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2020.

Charging state MKZ_CHRG_STATE

Pelican can show this parameter as the charging state.

  • Service 22DID 484F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1READYReady
2FAULTFault
3WAITWait Check
4PRE_CONDPre-condition
5CHARGINGCharging
6DONEDone
7EXTExternal Charger
8INITInitializing

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Commanded generator voltage MKZ_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

In testing for 2006 to 2020.

Contactor voltage negative MKZ_CONTACTOR_V_NEG

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2006 to 2020.

Contactor voltage positive MKZ_CONTACTOR_V_POS

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2006 to 2020.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2013. Supported for 2012, 2020.

DC-DC converter MKZ_DCDC_ENABLED

  • Service 22DID 483D
  • Module746 → 74E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

High voltage battery intake air temperature MKZ_HVBAT_IAT

  • Service 22DID 000F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

In testing for 2006 to 2020.

HV battery age MKZ_HVBAT_AGEConfirmed

  • Service 22DID 4810
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2006 to 2011, 2013 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×720200
Range
0 to 235926 h
Unit
h

0x886F = 34927 → 34927×720200 = 125,737.2 h

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.

HV battery charge MKZ_HVBAT_SOCConfirmed

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2006 to 2011, 2013 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 100 %
Unit
%

0x4280 = 17024 → 17024500 = 34.048 %

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.

HV battery charge, displayed MKZ_HVBAT_SOC_DISP

The state of charge displayed on the vehicle's dashboard.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4845
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

HV battery coolant inlet temperature MKZ_HVBAT_COOLANT_INLET_T

  • Service 22DID 4846
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2020.

HV battery energy MKZ_HVBAT_KWH

  • Service 22DID 4848
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131.07 kWh
Unit
kWh

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

HV battery state of health MKZ_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 490C
  • Module7E4 → 7EC
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

HV battery temperature MKZ_HVBAT_TConfirmed

  • Service 22DID 4800
  • Module7E4 → 7EC
  • Every10 s
  • Testing for 2006 to 2011, 2013 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x49 = 73 → 73−50 = 23 °C

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.

HV battery voltage MKZ_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 480D
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2006 to 2011, 2013 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

0x5BF1 = 23537 → 23537100 = 235.37 V

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.

HV negative leakage voltage MKZ_HV_NEG_LEAK_V

  • Service 22DID 4804
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2006 to 2020.

HV positive leakage voltage MKZ_HV_POS_LEAK_V

  • Service 22DID 4803
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2006 to 2020.

Low voltage converter input current MKZ_DCDC_HV_A

  • Service 22DID 483A
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 A
Unit
A

In testing for 2006 to 2020.

Low voltage converter output current MKZ_DCDC_LV_A

  • Service 22DID 4836
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2006 to 2020.

Maximum discharge power limit MKZ_MAX_DISCH_PWR_LIM

  • Service 22DID 4815
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25100
Range
0 to 63.75 kW
Unit
kW

In testing for 2006 to 2020.

Minimum battery module voltage MKZ_BATT_MIN_BATT_V

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2006 to 2020.

Normalized cumulative charge when ignition is on MKZ_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2006 to 2020.

Normalized cumulative discharge from battery with engine off MKZ_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2006 to 2020.

Normalized cumulative discharge from battery with engine on MKZ_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2006 to 2020.

Second battery current MKZ_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 2006 to 2020.

Second battery voltage MKZ_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2006 to 2020.

State of charge spread across battery modules MKZ_BATT_SOC

  • Service 22DID 483E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 %
Unit
%

In testing for 2006 to 2020.

Traction battery voltage, alternate MKZ_TRACTION_BAT_V_ALT

  • Service 22DID 490B
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 199 V
Unit
V

In testing for 2006 to 2020.

Voltage spread across battery modules MKZ_BAT_V_VARIATION_BAT

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2006 to 2020.

Climate

A/C compressor current MKZ_AC_COMP_A

  • Service 22DID 99AB
  • Module7C7
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10032767
Range
-100 to 100 A
Unit
A

In testing for 2006 to 2020.

A/C compressor pressure MKZ_AC_PConfirmed

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

0x0178 = 376 → 376×245251845473 = 109.068387 psi

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

A/C compressor pressure sensor voltage MKZ_AC_P_SENS_V

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2006 to 2020.

A/C compressor, state MKZ_AC_STATE

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2020.

A/C refrigerant pressure MKZ_PCM_A_C_REFRIG_P

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2006 to 2020.

Ambient temperature sensor voltage MKZ_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

0x016C = 364 → 364×51023 = 1.779081 V

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Ambient temperature, alternate MKZ_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2006 to 2020.

Control

Anti-lock brake lateral acceleration MKZ_ABS_LATERAL_ACCEL

  • Service 22DID 3A51
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g
Unit
g

In testing for 2006 to 2020.

Anti-lock brake wheel speed 1 MKZ_ABS_WHL_SPD_1

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2020.

Anti-lock brake wheel speed 2 MKZ_ABS_WHL_SPD_2

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2020.

Anti-lock brake wheel speed 3 MKZ_ABS_WHL_SPD_3

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2020.

Anti-lock brake wheel speed 4 MKZ_ABS_WHL_SPD_4

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2020.

Brake hydraulic pressure, raw count MKZ_BRK_FL_P

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Parking brake state MKZ_PARKING_BRAKE

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Steering wheel angle MKZ_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1638.4
Range
-1638 to 1638 °
Unit
°

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Doors

Driver door ajar MKZ_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Hood ajar? MKZ_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Lock status MKZ_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Passenger door ajar? MKZ_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Rear left door ajar? MKZ_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Rear right door ajar? MKZ_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Trunk ajar? MKZ_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Drivetrain

Primary motor inverter temperature MKZ_PRI_MOTOR_INV_T

  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2006 to 2020.

Primary motor inverter voltage MKZ_PRI_MOTOR_INV_V

  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

In testing for 2006 to 2020.

Primary motor speed MKZ_PRI_MOTOR_RPM

  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 2006 to 2020.

Primary motor torque MKZ_PRI_MOTOR_TQ

  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

In testing for 2006 to 2020.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2012 to 2013. Supported for 2020.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2012. Supported for 2013, 2020.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2012. Supported for 2013, 2020.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2012. Supported for 2013, 2020.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2012. Supported for 2013, 2020.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012. Supported for 2013, 2020.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2012. Supported for 2013, 2020.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012. Supported for 2013, 2020.

Engine

Accelerator position MKZ_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Actual engine percent torque MKZ_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Air conditioning pressure MKZ_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

In testing for 2006 to 2020.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2012.

Barometric pressure MKZ_BAROConfirmed

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

0x0195 = 405 → 405×61516963 = 14.683429 psi

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Barometric pressure MKZ_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2006 to 2020.

Barometric pressure sensor voltage MKZ_BARO_VConfirmed

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

0x0331 = 817 → 817×51023 = 3.993157 V

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Battery current MKZ_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2006 to 2020.

Boost MKZ_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2006 to 2020.

Bypass valve MKZ_BPV_OPEN

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2006 to 2020.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012. Supported for 2013, 2020.

Camshaft position error, exhaust MKZ_VCT_EXH_ERRConfirmed

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Camshaft position error, intake MKZ_VCT_INT_ERRConfirmed

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Camshaft position, exhaust actual MKZ_VCT_EXH_ACTConfirmed

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Camshaft position, exhaust desired MKZ_VCT_EXH_DESConfirmed

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Camshaft position, intake actual MKZ_VCT_INT_ACTConfirmed

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Camshaft position, intake desired MKZ_VCT_INT_DESConfirmed

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Camshaft solenoid duty cycle, exhaust MKZ_VCT_EXH_DUTYConfirmed

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Camshaft solenoid duty cycle, intake MKZ_VCT_INT_DUTYConfirmed

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×258192 = 0 %

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Catalyst temperature MKZ_CAT_TEMP

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2006 to 2020.

Charge air temperature MKZ_CAT

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

In testing for 2006 to 2020.

Charge air temperature sensor voltage MKZ_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2006 to 2020.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2012. Supported for 2013.

Commanded generator duty MKZ_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Coolant temperature MKZ_ECTConfirmed

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x109A = 4250 → 425064 = 66.40625 °C

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Cylinder 1 misfire count MKZ_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder 2 misfire count MKZ_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder 3 misfire count MKZ_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder 4 misfire count MKZ_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder 5 misfire count MKZ_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder 6 misfire count MKZ_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Cylinder head temperature MKZ_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2020.

Cylinder head temperature MKZ_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2006 to 2020.

Cylinder head temperature MKZ_PCM_CYL_HEAD_T_CORR

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2006 to 2020.

Cylinder head temperature, alternate MKZ_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2006 to 2020.

Cylinder head temperature, sensor 2 MKZ_PCM_CYL_HEAD_T_SENS_2_RAW

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2006 to 2020.

Distance since DTC clear MKZ_DIST_DTC_CLR

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2020.

Distance with MIL MKZ_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2020.

DTC counter MKZ_DTC_CNT

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012. Supported for 2013, 2020.

Engine load MKZ_ENG_LOAD_PCT

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Engine load, actual MKZ_ENG_LOAD_ACT

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2006 to 2020.

Engine oil temperature MKZ_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2006 to 2020.

Engine reference torque MKZ_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006 to 2020.

Engine run time MKZ_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2006 to 2020.

Engine run time MKZ_RUN_TIME

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2006 to 2020.

Engine speed MKZ_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2020.

Evaporative pressure sensor, raw count MKZ_EVAP_RAWConfirmed

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0650 = 1616 → 1,616

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Evaporative purge MKZ_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Exhaust gas recirculation MKZ_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Exhaust gas recirculation duty cycle MKZ_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Exhaust gas temperature 1 MKZ_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2006 to 2020.

Exhaust gas temperature 2 MKZ_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2006 to 2020.

Fuel pressure sensor voltage, low MKZ_LPFP_SENS_V

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2006 to 2020.

Fuel pressure, low actual MKZ_LPFP_ACT

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

In testing for 2006 to 2020.

Fuel pressure, low desired MKZ_LPFP_DES

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

In testing for 2006 to 2020.

Fuel pump duty cycle, low pressure MKZ_LPFP_DUTYConfirmed

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

0x1E02 = 7682 → 7682×258192 = 23.443604 %

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Fuel pump pulse width, bank 2 MKZ_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2006 to 2020.

Fuel rail pressure, desired MKZ_HPFP_DESConfirmed

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0025 = 37 → 37×10 = 370 kPa

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Fuel rail sensor voltage, high pressure MKZ_HPFP_VConfirmed

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Fuel trim, long term MKZ_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2006 to 2020.

Fuel trim, short term MKZ_STFT

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2006 to 2020.

Generator coil temperature MKZ_GEN_COIL_T

  • Service 22DID 4972
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×180+320
Range
0 to 11796620 °F
Unit
°F

In testing for 2006 to 2020.

Generator coil temperature MKZ_GEN_COIL_T_7E6

  • Service 22DID 4820
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95
Range
-58982 to 58980 °C
Unit
°C

In testing for 2006 to 2020.

Generator control MKZ_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Generator current MKZ_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

In testing for 2006 to 2020.

Grill shutter duty cycle MKZ_GRILL_SHUT_DC

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Grill shutter position MKZ_GRILL_SHUTTER_POS

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

High voltage battery current MKZ_HIGH_V_BAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2006 to 2020.

Ignition correction, cylinder 1 MKZ_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2006 to 2020.

Ignition timing, cylinder 1 MKZ_IGN_TIM_CYL1

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

In testing for 2006 to 2020.

In car temperature MKZ_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2006 to 2020.

Injection mode MKZ_INJ_MODE

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2006 to 2020.

Injector impulse width MKZ_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2006 to 2020.

Intake air temperature 2 MKZ_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2006 to 2020.

Intake temperature fault MKZ_IAT_FAULT

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Intake temperature sensor voltage MKZ_IAT_SENS_V

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2006 to 2020.

Intake temperature, alternate MKZ_IAT_ALT2

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2020.

Knock counter, cylinder 1 MKZ_PCM_CYL_1_KNK_COMB_PERF_CNT

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock counter, cylinder 2 MKZ_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock counter, cylinder 3 MKZ_PCM_CYL_3_KNK_COMB_PERF_CNT

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock counter, cylinder 4 MKZ_PCM_CYL_4_KNK_COMB_PERF_CNT

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock counter, cylinder 5 MKZ_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock counter, cylinder 6 MKZ_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Knock sensor, 1 MKZ_KS1_RAW

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Knock sensor, 2 MKZ_KS2_RAW

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2012.

Lambda correction MKZ_CL_LCConfirmed

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

0x0000 = 0 → 08192 = 0

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Lambda, commanded MKZ_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

In testing for 2006 to 2011. Not supported for 2012.

Manifold absolute pressure, high resolution MKZ_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

In testing for 2006 to 2020.

Manifold pressure MKZ_MAP

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

In testing for 2006 to 2012.

Manifold pressure sensor voltage MKZ_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Manifold temperature MKZ_MCTConfirmed

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

0x00 = 0 → 0 °C

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Misfire acceleration, cylinder 1 MKZ_PCM_MISF_ACCEL_CYL1_NORM

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire acceleration, cylinder 2 MKZ_PCM_MISF_ACCEL_CYL2_NORM

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire acceleration, cylinder 3 MKZ_PCM_MISF_ACCEL_CYL3_NORM

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire acceleration, cylinder 4 MKZ_PCM_MISF_ACCEL_CYL4_NORM

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire acceleration, cylinder 5 MKZ_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire acceleration, cylinder 6 MKZ_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2006 to 2020.

Misfire events, latest cycle MKZ_PCM_MISF_EVENTS_LATEST_CYC

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2006 to 2020.

Motor coil temperature MKZ_MOTOR_COIL_T

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95+32
Range
-58950 to 59012 °F
Unit
°F

In testing for 2006 to 2020.

Motor electronic coolant temperature II MKZ_MOTOR_ELECTRONIC_ECT

  • Service 22DID 4983
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

In testing for 2006 to 2020.

Motor electronics coolant temperature MKZ_MOTOR_ELECTRONICS

  • Service 22DID 4832
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95+32
Range
0 to 491 °F
Unit
°F

In testing for 2006 to 2020.

O2 sensor voltage, rear MKZ_RO2_VConfirmed

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Octane adjustment MKZ_OARConfirmed

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2011, 2014 to 2020

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Oil life remaining MKZ_PCM_ENG_OIL_LIFE_REM

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Oil pressure MKZ_PCM_ENG_EOP_RAW

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2006 to 2020.

Outside temperature MKZ_OUTSIDE_T

  • Service 22DID DD05
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−38
Range
-38 to 421 °F
Unit
°F

In testing for 2006 to 2020.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2012. Supported for 2013, 2020.

Sump oil temperature measured MKZ_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2020.

Temperature inside car MKZ_T_INSIDE_CAR

  • Service 22DID DD04
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2006 to 2020.

Throttle angle, actual MKZ_ETC_ANG_ACT

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2006 to 2020.

Throttle angle, desired MKZ_ETC_ANG_DES

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2006 to 2020.

Throttle control trim angle, learned MKZ_ETC_TRIM_LRNConfirmed

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2011, 2014 to 2020

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Throttle inlet pressure MKZ_TIP_ABSConfirmed

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

0x33EC = 13292 → 13292×3733441 = 14.706618 psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Throttle inlet pressure sensor voltage MKZ_TIP_VConfirmed

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

0x014E = 334 → 334×51024 = 1.630859 V

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Throttle inlet pressure, desired MKZ_TIP_DES_ABS

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

In testing for 2006 to 2020.

Time since last oil change MKZ_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2006 to 2020.

Torque converter slip MKZ_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2006 to 2020.

Torque into torque converter MKZ_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2006 to 2020.

Torque into torque converter MKZ_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2006 to 2020.

Torque request MKZ_TRQ_CTRL_REQ

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Total misfire count MKZ_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2020.

Transfer case fluid temperature MKZ_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2006 to 2020.

Transmission fluid temperature, variant 1 MKZ_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2006 to 2020.

Transmission fluid temperature, variant 2 MKZ_ATF_T_VAR_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2006 to 2020.

Transmission fluid temperature, variant 5 MKZ_ATF_T_VAR_5

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2006 to 2020.

Transmission fluid temperature, variant 6 MKZ_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2006 to 2020.

Transmission oil temperature MKZ_TOT_7E0Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

0x0233 = 563 → 56316 = 35.1875 °C

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Turbo boost MKZ_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2006 to 2020.

Turbo inlet pressure MKZ_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2006 to 2020.

Warm-ups since DTC clear MKZ_WARMUP_CLR

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2020.

Wastegate control MKZ_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

Wastegate duty cycle MKZ_WGDC

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2006 to 2020.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2012. Supported for 2020.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2012. Supported for 2020.

Fuel

Air/fuel ratio MKZ_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

In testing for 2006 to 2020.

Engine fuel rate MKZ_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

In testing for 2006 to 2020.

Fuel injection impulse width MKZ_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2006 to 2020.

Fuel level MKZ_FLI_16C1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2006 to 2020.

Fuel level MKZ_FLI_7E0Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x56 = 86 → 86×100255 = 33.72549 %

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Fuel pump duty cycle MKZ_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2006 to 2020.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013. Supported for 2012, 2020.

Fuel tank level MKZ_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Fuel tank pressure MKZ_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2006 to 2020.

Fuel temperature MKZ_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2020.

Lights

Exterior lighting state MKZ_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

High beam status MKZ_HIGH_BEAM

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Movement

Accelerator pedal position MKZ_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2006 to 2020.

Fan speed demanded MKZ_FAN_SPD_DEMANDED

  • Service 22DID 0701
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2006 to 2020.

Fan speed indicated MKZ_FAN_SPD_INDICATED

  • Service 22DID 0702
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2006 to 2020.

Fan speed sensor MKZ_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2006 to 2020.

Fan speed, desired MKZ_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

In testing for 2006 to 2012.

Front left wheel speed MKZ_FL_VSS

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2006 to 2020.

Front right wheel speed MKZ_FR_VSS

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2006 to 2020.

Lateral acceleration MKZ_LAT_G

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

In testing for 2006 to 2020.

Lateral angle, raw count MKZ_LAT_ANG

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2006 to 2020.

Rear left wheel speed MKZ_RL_VSS

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2006 to 2020.

Rear right wheel speed MKZ_RR_VSS

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2006 to 2020.

Traction motor speed MKZ_TRACTION_MOTOR_SPD

  • Service 22DID 496A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 rpm
Unit
rpm

In testing for 2006 to 2020.

Vehicle speed MKZ_VSS

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2006 to 2020.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2012 to 2013. Supported for 2020.

Vehicle speed, high resolution MKZ_VSS_HD

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

In testing for 2006 to 2020.

Tires

4 wheel drive engaged MKZ_4_WHL_DRIVE_ENGAGED

  • Service 22DID A211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2006 to 2020.

Front left tire pressure MKZ_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x02BF = 703 → 70320 = 35.15 psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Front right tire pressure MKZ_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x026F = 623 → 62320 = 31.15 psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Rear left inner tire pressure slot MKZ_TP_RLI_RAWConfirmed

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2818
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x010E = 270 → 270

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Rear left tire pressure MKZ_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x02A1 = 673 → 67320 = 33.65 psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Rear right inner tire pressure slot MKZ_TP_RRI_RAWConfirmed

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2817
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x010E = 270 → 270

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Rear right tire pressure MKZ_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every15 s
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x02B0 = 688 → 68820 = 34.4 psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Tire pressure warning indicator MKZ_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every15 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Transmission

Axle gear ratio, measured MKZ_AXLE_GEAR_RATIO_MEAS

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

In testing for 2006 to 2020.

Converter speed ratio MKZ_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2006 to 2020.

Current gear MKZ_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2006 to 2012, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → 1

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Current gear, transmission module MKZ_GEAR_V2Confirmed

The automatic transmission gear, as the transmission module reports it.

  • Service 22DID 1E12
  • Module7DF → 7E9
  • Every30 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x32 = 50 → NEUTRAL

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Supported for 2013.

Gear commanded MKZ_GEAR_CMD

  • Service 22DID 1E12
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNKNOWNUnknown
20L
40D
50N
60R
70P
255FAULTFault

In testing for 2006 to 2020.

Gear ratio, commanded MKZ_PCM_CMD_TRANS_GEAR_RATIO

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2006 to 2020.

Gear, engaged MKZ_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2006 to 2020.

Gear, shift MKZ_GEAR_SHFTConfirmed

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x0A = 10 → MANUAL

States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Torque converter line pressure MKZ_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2006 to 2020.

Torque into torque converter, variant 2 MKZ_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2006 to 2020.

Transmission gear MKZ_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2006 to 2020.

Transmission gear MKZ_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2006 to 2020.

Transmission gear ratio MKZ_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2006 to 2020.

Transmission odometer MKZ_TRANS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006 to 2020.

Transmission oil temperature MKZ_TOT_V2Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7DF → 7E9
  • Every1 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2012 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

0x0163 = 355 → 35516 = 22.1875 °C

Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Supported for 2013.

Transmission output shaft speed MKZ_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2006 to 2020.

Transmission pressure, commanded MKZ_PCM_CMD_TRANS_MAIN_LINE_P

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2006 to 2020.

Transmission temperature MKZ_TT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-300 to 300 °C
Unit
°C

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Trips

Distance since last oil change MKZ_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2006 to 2020.

Distance to empty, calculated MKZ_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2006 to 2020.

Distance to empty, displayed MKZ_DTE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2006 to 2020.

Maximum battery temperature MKZ_HVBAT_T_MAX

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2020.

Minimum battery temperature MKZ_HVBAT_T_MIN

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2020.

Odometer MKZ_BECM_ODO

  • Service 22DID 6182
  • Module7E4 → 7EC
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12815625
Range
0 to 536
Unit
Number

In testing for 2006 to 2020.

Odometer MKZ_IPC_ODO

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Odometer MKZ_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006 to 2011, 2014 to 2020

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x04EF4E = 323406 → 323,406 km

Confirmed for 2012 to 2013. In testing for 2006 to 2011, 2014 to 2020.

Odometer MKZ_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2006 to 2020.

Odometer, instrument panel MKZ_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Trip distance MKZ_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.

Vehicle odometer MKZ_PCM_VEH_ODO

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2006 to 2020.